- 05000370/LER-1996-001-03, :on 960208,unit 2 RWST Level Instrumentation Inoperable Due to Cold Water Condition.Caused by Insufficient Monitoring.Fw Level Transmitter Panel Will Be Verified + (ML20101A197)
- 3F0396-06, Monthly Operating Rept for Feb 1996 for Crystal River Unit 3 + (ML20101A207)
- ML20101A208 + (ML20101A208)
- ML20101A214 + (ML20101A214)
- ML20101A219 + (ML20101A219)
- ML20101A222 + (ML20101A222)
- ML20101A226 + (ML20101A226)
- ML20101A229 + (ML20101A229)
- ML20101A236 + (ML20101A236)
- ML20101A242 + (ML20101A242)
- W3P84-3506, Advises of Commitment to Have Operable Toxic Gas Detection Sys Indicating Presence of Toxic Gases at Control Room Air Intakes by 850701,per Sser 6 + (ML20101A244)
- B11398, Application for Amend to License DPR-65,revising Tech Specs Re Containment Penetration.Fee Paid + (ML20101A249)
- ML20101A260 + (ML20101A260)
- ML20101A277 + (ML20101A277)
- ML20101A281 + (ML20101A281)
- ML20101A285 + (ML20101A285)
- ML20101A368 + (ML20101A368)
- 3F1284-09, Forwards Ltrs Submitted to Epa,Per Tech Spec App B Part II Section 3.2.Encls May Not Have Been Submitted to NRC + (ML20101A373)
- ML20101A374 + (ML20101A374)
- ML20101A396 + (ML20101A396)
- ML20101A428 + (ML20101A428)
- ML20101A434 + (ML20101A434)
- 3F0492-09, Forwards Rev 4 to Cycle 8 Core Operating Limits Rept + (ML20101A437)
- ML20101A440 + (ML20101A440)
- ML20101A444 + (ML20101A444)
- ML20101A447 + (ML20101A447)
- ML20101A449 + (ML20101A449)
- ML20101A456 + (ML20101A456)
- ML20101A465 + (ML20101A465)
- ML20101A478 + (ML20101A478)
- ML20101A481 + (ML20101A481)
- ML20101A490 + (ML20101A490)
- ML20101A502 + (ML20101A502)
- TXX-4372, Deficiency Rept SDAR-148 Re Preoperational Testing Activities at Facilities.Initially Reported on 840829. Complete Investigation Concluded That Condition Not Reportable Per 10CFR50.55(e) + (ML20101A531)
- 1CAN049201, Forwards Rev 0 to, Arkansas Nuclear One - Unit 1 Cycle 11 Core Operating Limits Rept + (ML20101A544)
- ML20101A548 + (ML20101A548)
- ML20101A559 + (ML20101A559)
- ML20101A561 + (ML20101A561)
- ML20101A564 + (ML20101A564)
- RBG-19553, Interim Deficiency Rept DR-242 Re Fracture of Pinion Gear in Limitorque Motor Operator for RHR Sys Safety Valve.Next Rept Will Be Submitted by 850130 + (ML20101A592)
- ML20101A604 + (ML20101A604)
- ML20101A622 + (ML20101A622)
- ML20101A624 + (ML20101A624)
- ML20101A629 + (ML20101A629)
- 3F1284-08, Forwards Revised General Info Re Fire Protection,App R Exemption Requests,Per 841023 & 24 Meetings.Encl Supersedes 840924 & 1005 Technical Exemption Requests + (ML20101A650)
- RBG-19556, Interim Deficiency Rept DR-222 Re Relocation of Div III 125-volt Dc Panel.Next Rept Will Be Submitted by 850207 + (ML20101A681)
- ML20101A688 + (ML20101A688)
- RBG-19552, Interim Deficiency Rept DR-236 Re Piston Wrist Pins in Tdi Standby Diesel Generator.Next Rept Will Be Submitted by 850117 + (ML20101A728)
- RBG-19559, Interim Deficiency Rept DR-173 Re Elbows Supplied by GE for Main Steam Sys.Next Rept Will Be Submitted by 841213 + (ML20101A730)
- ML20101A741 + (ML20101A741)
- LIC-96-0006, Requests Relief from ASME Boiler & Pressure Vessel Code, Section III Overpressure Protection Requirements for Chemical & Vol Control Sys + (ML20101A743)