ML20101A208

From kanterella
Jump to navigation Jump to search
Forwards Addl Clarification of Position Re NUREG-0737 post-accident Sampling & Monitoring Capabilities.Five Addl Items Identified for NRC Review & Concurrence
ML20101A208
Person / Time
Site: Fermi 
Issue date: 12/13/1984
From: Jens W
DETROIT EDISON CO.
To: Youngblood B
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737 EF2-72030, NUDOCS 8412180248
Download: ML20101A208 (10)


Text

.

, Wayne H. Jens V<> President

  • Nuclear Operatais -

orth Dine Highway -

ISOn Newport, Mchigan 48166 ota> saS4 iso December 13, 1984 EF2-72030 Director of Nuclear Reactor Regulation Attention:

Mr. B. J. Youngblood Licensing Branch No. 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.

20555

References:

1.

Fermi'2 NRC Docket No. 50-341 2.

Detroit Edison to NRC Letter, " Action Plan for Completing NRC Open Items Related to PRMS and PASS", EF2-70036 dated October 31, 1984.

3.

Detroit Edison to NRC Letter, "Clarifi-cation of Position Regarding NUREG-0737 Post-Accident Sampling and Monitoring Capabilities", EF2-72006 dated November 1, 1984.

4.

USNRC Region III Inspection Report No. 50-341/84-27, dated August 10, 1984.

Subject:

Additional Clarification of Position Regarding NUREG-0737 Post-Accident Sampling and Monitoring capabilities

Dear Mr. Youngblood:

The reference (3) submittal contains several items identi-fled by Detroit Edison for your review and concurrence.

The purpose of this letter is to identify an additional 5 items relating to NUREG-0737 Post-Accident Sampling and Monitoring capabilities which also require your review and concurrence.

The items are summarized as follows:

a. :

Empirical Determination of Sample Line Loss Correction Factors

b. :

Effluent Radiation Monitors -

Main Control Room Displays

c. :

Heat Tracing of SGTS Sample Lines ONoM 0\\

A

&0,4 von

~

Mr. B.-J.,Youngblood December 13, 1984

.EF2-72030 Page 2

+

d. :

Location of Containment Area

,High, Range MonitoringlSystem (CAHRMS) Detectors

~

J

e. :

Isok'inetic Conditions If youthave any further questions please contact Mr. O. K.

Earle (313) 586-4211.

Sincerely,

(

l

[hWk Idb Enclosures cc:

All with Enclosures

.Mr. P. M.

Byron Mr. C. Gill Mr. L. Heuter USNRC, Document Control Desk Washington, D.C.

20555

m

[jg, W

'=-

[

q.

~

j s,

- 7 ENCLOSURE 1 EMPIRICAL. DETERMINATION OF SAMPLE LINE LOSS: CORRECTION FACTORS' NRC Region III' raised the following concern during a n

~

7 previous inspection--(1):

1The' licensee has-not yet= arrived at correction factors

'for sample line: losses due to' iodine plateout.and particulate deposition.

As clarified in footnote 12 of Table 3 of Regulatory Guide 1.97 (Revision.3),

" collection of. representative-samples" means obtaining

'the best samples practicable given the exigencies that attend'the accident environments..Line losses or~line deposition should be empirically pre-determined and-appropriate loss correction factors-should be applied.

It has-been noted by. Detroit Edison.that NUREG-0737 does not contain a specific requirement or recommendation for empirically determining sample line loss correction factors.

In addition, Detroit Edison's' commitments (in the Fermi 2 FSAR) refer.to Revision 2'of Regulatory _; Guide 1.97.

' Detroit' Edison has reviewed a-recent article relating to the plateout.of radioiodine.in~ sample lines (:2).

Included in this article is a method for celculating potential sample line losses for various iodine chemical species.

Detroit Edison has used this method to estimate expected iodine sample line losses of approximately 104.

One assumption which was used in estimating the lodine sample line loss regarded the anticipated distribution of iodine ~ chemical species.

The basis for this assumption was taken from an EPRI study of BWR.radiolodine sources (3).. It is noted that this study. refers to routine operating

' conditions.

However, no credible reference could'be found with regards to thefdistribution of radioiodine' chemical species expected during accident conditions.

In addition, Detroit Edison has calculated-expected particulate sample line losses using.the methods described in ANSI N13.1 (4).

These line losses are estimated at-less than 20%.

Sample line loss correction factors, based upon these calculated values, are being incorporated into related procedures.

o e

t 4

8 g

g g

b

't Enclosure ~ l Page 2 Detroit Edison has agreed to develop a test scope for empirically determining sample line losses prior to March

[

31, 1985 (5).

In addition to selecting an acceptable and cost-effective test method, an evaluation is being made

~

regarding the applicability of test results, in light of the lack of quantitative data regarding iodine chemical species and particulate size distribution expected during design basis accident conditions.

A decision regarding the actual performance of the test will be based upon sound engineering-and economic considerations.

~ In summary, it is Detroit Edison's position that the existing system design'and procedures, taking into account the above comments, meet the commitments to NUREG-0737 with regards to representative sampling of radiciodines and particulates.

(1)

USNRC Region III Inspection Report No. 50-341/84-27, Dnted August 10, 1984.

(2)

M.

T. Kabat, Deposition of Airborne Radiciodine Species on Surfaces of Metals and Plastics, Proceedings of the 17th DOE Air Cleaning Conference, 1982.

(3) _ EPRI NP-495, Sourcos of Radiolodine at Boiling Water Reactors, prepared by Science Applications, Inc.,

February 1978.

(4). ANSI N13.1-1969, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities.

(5)

Detroit Edison to NRC Region Letter, " Action Plan for Completing NRC Open Items Related to PRMS and PASS,"

EF2-70036 Dated October 31, 1984.

~.

~

~

+s

.2

. ENCLOSURE 2 q.

' EFFLUENT-RADIATION MONITORS-MAIN' CONTROL ROOM DISPLAYS

.ALpermanent waiver is requested-from NUREG-0737,' Item.

II.F.1, Attachment 1 which requirealth'e monitor display and, srecording be in terms of uCi/cc of Xe-133 equivalent or-actual noble gas' mix.

The' waiver is requested to. acknowledge.the acceptability of-main control; room displays which include:~

1.

An en-demand digital display for the Eberline System Particulate, Iodine and Noble Gas-(SPING) monitors and AXM accident monitors capable of reading uCi/cc of " pseudo noble gas"* for each of the two noble gas channels.

(Three noble ~ gas channels on the SPING-4,: Reactor Building Exhaust-Plenum).

2.

Recording by digital data system of detector readings in uCi/cc.of pseudo noble gas.

The weighted sensitivities to this " pseudo noble gas" will be programmed'into the Eberline microprocessor as uCi/cc of Xe-133 equivalent.

r Calculations in the microprocessor using channelLsensitivity and counts per minute will yield uCi/cc ofL" pseudo noble gas".

The digital display located in the control room will.

be able to retrieve from the microprocessor the following information:

~

1.-

Counts per minute 2.

Concentration of " pseudo noble gas" (uci/cc).

This waiver is requested because the offsite dose assessment models used by Detroit Edison for accident cases are based on. effluent noble gas monitor. readings of " pseudo noble gas" (as Xe-133 equivalent).

The~models provide-the capability to include the time dependence required to account for the decay of the actual mix relative to the " pseudo ~ noble gas".

Radiological Emergency Response Preparedness (RERP) Imple-menting Procedure EP-540, " Manual Off-Site Radiological, Dose Assessment Calculational Procedure - Airborne Releases'-

Overview" uses a series,of curves of elease rate of~Xe-133 s

  • " Pseudo noble gas" at Fermi 2fis defined as'the isotopic mix of the weekly grab sample of noble gases calculated as Xe-133 equivalent.

m Page 2 equivalents'which.are calculated from post-LOCA noble gas mix, conversion factors and, in some cases, sampl e ' analyses to correlate effluent monitor readings to an estimated noble gas release rate following an accident.

This procedure was found acceptable as noted in NUREG-0798, Supplement 4,

~Section 13.3.2.9.

The computerized model, an integral part of'the Emergency Response Information System (ERIS), also incorporaces the use of the " pseudo noble gas" as Xe-133 equivalent and per-forms the required' calculations to provide release rate based'on default isotopic mixes or actual sample.analysea.

A permanent waiver.is requested.

s

7 c

ENCLOSURE 3 f

HEAT TRACING OF STANDBY GAS TREATMENT SYSTEM (SGTS)

SAMPLE LINES Installation,;preoperational testing, procedures and training in the.use of the SGTS sampling and monitoring equipment is complete.

The SGTS sample lines will'be heat traced to enhance'the. post-accident sampling capabilities of the equipment.

This heat tracing will be completed prior to exceeding 5% power.

A waiver is requested.

f L. _

7= -.

["

lL p

ENCLOSURE:5

' ISOKINETIC CONDITIONS.

' Detroit-Edison has installed isokinetic probes which sample

'the radioactive' gaseous effluent' releases from the-Fermi 2-

. plant.' Due to the balancing:of the. heating, ventilation, and' air conditioning-(HVAC)-system,.and physical-changes.in building: pathways. currently taking place,1 flows ~in these-

-effluent: stacks and ducts: are changing.

These changes yield depar-tures from. isokinetic ~ conditions as initially

' designed.

As changes in the HVAC' system. continue, Detroit' Edison.has-

. set up a program to measure effluent flows periodically.--

These data will.be evaluated and sample flows will be changed if necessary to maintain reasonable isokinetic con-ditions per ANSI N13.1-1969..This program will. remain in affect'for'a'minimumfof one year, at/which. time it is pre-dicted'that'the flowstwill have stabilized.

The!above is submitted for clarification of. Detroit Edison's

~

planned effort for maintaining isokinetic conditions.-

]

4 e %-w w me

  • m-we

--e--

-w v-wwm---

,e-

s.-

' ENCLOSURE 4'

. LOCATION OF CONTAINMENT AREA HIGH RANGE MONITORING SYSTEM

'(CAHRMS) DETECTORS

~

4

-The CAHRMS detectors at Fermi =2 are located in-the drywell.

Radial placement has positioned the detectors at:

' 'approximately 6-7 feet from the sacrificial shield wall.

-The.present location.of the CAHRMS is~ considered to be optimum when considering.the large amount of. equipment, structures, and piping-in.the-drywell.

- The locationarof'the CAHRMS monitors are presently being evaluated taking.into account the as-built geometry.in.the drywell and the instrument calibration factors for gamma' ray energy.

If necessary, instrument response factors will be included in. accident-type RERP~ implementing procedures, and

. models.for off-site dose-calculation, as well as other

. associated RERP implementing. procedures, that may involve the CAHRMS monitors.

- The evaluation and necessary procedural modifications will' be completed prior to 5% power.

A waiver is requested.

( x t.

k

r -' :,

e e

  • D LBP/100/LIC-23/6.0 121284'