- ML20099G974 + (ML20099G974)
- ML20099G979 + (ML20099G979)
- ML20099G990 + (ML20099G990)
- 05000327/LER-1985-011, :on 850206,08,12,13,15 & 28,hourly Fire Watch Not Performed within 1 H.Caused by Equipment Failures. Equipment Repaired & Fire Watches Completed 3 H After Last Watch + (ML20099G991)
- ML20099H001 + (ML20099H001)
- 05000397/LER-1984-116, :on 841021,startup Surveillance on APRMs Revealed That Neutron flux-high Setdown Trip Set Beyond Tech Spec Limits.Investigation Initiated to Determine Cause. Trips Reset + (ML20099H011)
- 05000249/LER-1984-018-05, :on 841020,reactor Scrammed on Low Water Level W/Feedwater Regulating Valve 3A in Auto.Caused by Bad Switch in Reset Circuitry of Controller.Master Controller Replaced + (ML20099H014)
- 05000247/LER-1984-015, :on 841008,spurious Safety Injection Signal Occurred Due to Momentary Loss of Vital Instrument Bus. Caused by Defective Procedure & Operator Error.Operating Condition Restored.Procedure Revised + (ML20099H016)
- ML20099H019 + (ML20099H019)
- 05000328/LER-1984-019-02, :on 841017,surveillance Testing of Centrifugal Charging Pumps Revealed Injection Flow Rates Failed to Meet Tech Spec Requirements.Caused by Degradation of Pumps. Methods to Correct Condition Evaluated + (ML20099H020)
- 05000237/LER-1985-004-04, :on 850206,reactor Protection Sys Power Supply Switched from Reserve to Normal,Causing Channel B to Become Deenergized,Resulting in Full Scram.Procedure Will Be Created to Prevent Recurrence + (ML20099H029)
- RBG-20238, Final Deficiency Rept DR-200 Re Foreign Substances in Reactor Pressure Vessel.Exam Revealed That Substance Would Not Contribute to Stress Corrosion Cracking or Sys Coolant Corrosion.Condition Not Reportable Per 10CFR50.55(e) + (ML20099H030)
- ML20099H032 + (ML20099H032)
- 05000373/LER-1985-017-01, :on 850208,reactor Scrammed on Low Reactor Vessel Level.Caused by Placing Defective Jumper in Feedwater Pump NPSH Trip Circuit.Circuit Modified.Oil Sys Flushed + (ML20099H041)
- ML20099H042 + (ML20099H042)
- 05000397/LER-1984-115, :on 841023,automatic Reactor Protection Sys Trip Occurred.Caused by Increase in Vessel Level Due to Broken Actuator & Position Feedback Arm.Actuator Removed & Replaced W/Stainless Steel Tube + (ML20099H050)
- ML20099H052 + (ML20099H052)
- ML20099H055 + (ML20099H055)
- ML20099H058 + (ML20099H058)
- HL-2369, Monthly Operating Repts for Jul 1992 for Ei Hatch Units 1 & 2 + (ML20099H060)
- ML20099H061 + (ML20099H061)
- ML20099H070 + (ML20099H070)
- ML20099H080 + (ML20099H080)
- DCL-85-074, Final Deficiency Rept Re Cracks in Welds on Pipe Rupture Restraints Made by Pullman Power Products.Unacceptable Welds Repaired or Modified + (ML20099H091)
- ML20099H092 + (ML20099H092)
- ML20099H097 + (ML20099H097)
- NRC-92-0095, Responds to NRC 920730 Meeting Request for Addl Info Re 910924 Application for Amend to License NPF-43 Covering Use of Shex Computer Code in Power Uprate Safety Analysis + (ML20099H100)
- ML20099H102 + (ML20099H102)
- ML20099H103 + (ML20099H103)
- ML20099H107 + (ML20099H107)
- BECO-92-097, Application for Amend to License DPR-35,revising TS Surveillance Requirements & Associated Bases for Station Batteries to Conform W/Industry Practices & Mfg Recommendations + (ML20099H110)
- ML20099H113 + (ML20099H113)
- ML20099H118 + (ML20099H118)
- ML20099H120 + (ML20099H120)
- ML20099H121 + (ML20099H121)
- ML20099H125 + (ML20099H125)
- 05000388/LER-1985-006, :on 850129,w/unit in Hot Shutdown,Rhr Sys Shutdown Cooling Suction Inboard Isolation Valve Closed Unexpectedly.Possibly Caused by Faulty Pressure Switch. Switch May Be Replaced Pending Evaluation + (ML20099H127)
- ML20099H129 + (ML20099H129)
- ML20099H133 + (ML20099H133)
- ML20099H135 + (ML20099H135)
- HL-2361, Responds to NRC Re Violations Noted in Insp Rept 50-321/92-15.Corrective Actions:Pm&Ms Personnel Counseled Re Inappropriate Actions & Dept Issued Directive Informing Personnel That Special Procedures to Be Followed + (ML20099H140)
- ML20099H141 + (ML20099H141)
- ML20099H145 + (ML20099H145)
- ML20099H146 + (ML20099H146)
- ML20099H157 + (ML20099H157)
- ML20099H160 + (ML20099H160)
- ML20099H161 + (ML20099H161)
- ML20099H164 + (ML20099H164)
- ML20099H165 + (ML20099H165)
- ML20099H166 + (ML20099H166)
- ML20099H170 + (ML20099H170)