- ML20086K187 + (ML20086K187)
- ML20086K189 + (ML20086K189)
- AECM-84-0013, RO 83-115/0:on 831212,Fire Rated Door 1A301 from Auxiliary Bldg to Turbine Bldg Would Not Close.Caused by Heavy Use Damaging Door Closer.Door Restored on 840111 + (ML20086K193)
- 05000301/LER-1991-005-01, :on 911111,determined That Both Safety Injection Pump Breakers Racked in W/Rcs Temperature Less than 270 F.Caused by Procedural Inadequacy.Operator Aids Will Be Installed in Vicinity of Subj Breakers + (ML20086K194)
- ML20086K195 + (ML20086K195)
- 05000373/LER-1991-015-03, :on 911107,determined That Certain ESF Bus Under Voltage Relay Contacts Were Not Functionally Tested. Caused by Inadequate Testing Procedures.Undervoltage Trip Paths Tested & Test Procedures Will Be Revised + (ML20086K197)
- 05000260/LER-1983-082-03, /03L-0:on 831223,during Normal Operation, Recirculation Pump 2A Tripped Due to Actuation of Relay 2A-K21A Neutral Overvoltage.Caused by Gouged Insulation on Phase C Conductor in Cable 2PP1005 + (ML20086K198)
- ML20086K204 + (ML20086K204)
- 05000278/LER-1991-017-02, :on 910924,Automatic Depressurization Sys Discovered Inoperable Due to Components Being Unqualified. Caused by MSRV Thermal Insulation Being Improperly Installed.Subj Insulation Properly Reinstalled + (ML20086K206)
- ML20086K207 + (ML20086K207)
- BSEP-84-0092, Ro:On 831212,double Fire Door 110 Declared Inoperable Because of Encountered High Differential Air Pressure Across Door,Preventing Automatic self-closure.Plant Engineer Requested to Evaluate Problem + (ML20086K211)
- ML20086K214 + (ML20086K214)
- ML20086K215 + (ML20086K215)
- ML20086K216 + (ML20086K216)
- ML20086K218 + (ML20086K218)
- ML20086K223 + (ML20086K223)
- ML20086K226 + (ML20086K226)
- ML20086K227 + (ML20086K227)
- 05000361/LER-1983-092-03, /03L-0:on 831218,containment Airborne Radiation Monitor Rendered Inoperable When Sample Pump Motor Breaker Tripped.Caused by Insufficient Margin Between Motor Operating Current & Thermal Overload Setpoint + (ML20086K229)
- ML20086K231 + (ML20086K231)
- ML20086K234 + (ML20086K234)
- 05000361/LER-1983-152-03, /03L-0:on 831213,while in Mode 4,remote Shutdown Boronometer 2AI-0203B Found Inoperable.Caused by Failed Display.Display Unit Replaced + (ML20086K236)
- ML20086K252 + (ML20086K252)
- ML20086K254 + (ML20086K254)
- ML20086K255 + (ML20086K255)
- ML20086K258 + (ML20086K258)
- BECO-95-074, Application for Amend to License DPR-35,reflecting Use of Advanced GE-11 Fuel Design in Cycle 11 + (ML20086K259)
- ML20086K261 + (ML20086K261)
- ML20086K265 + (ML20086K265)
- ML20086K266 + (ML20086K266)
- ML20086K269 + (ML20086K269)
- ML20086K280 + (ML20086K280)
- ML20086K281 + (ML20086K281)
- 05000336/LER-1995-024, :on 950614,surveillance Frequency for Fire Detection Instrumentation Was Incorrect Due to Personnel Error.Revised Applicable Surveillance Procedure That Changed Frequency to Required semi-annual Interval + (ML20086K284)
- ML20086K286 + (ML20086K286)
- ML20086K288 + (ML20086K288)
- ML20086K290 + (ML20086K290)
- B15296, Application for Amend to License NPF-49 Re 24-month Fuel Cycle Surveillance Extensions for ECCS + (ML20086K292)
- ML20086K296 + (ML20086K296)
- ML20086K302 + (ML20086K302)
- ML20086K304 + (ML20086K304)
- ML20086K305 + (ML20086K305)
- ML20086K308 + (ML20086K308)
- ML20086K311 + (ML20086K311)
- ML20086K316 + (ML20086K316)
- ML20086K317 + (ML20086K317)
- ML20086K318 + (ML20086K318)
- ML20086K322 + (ML20086K322)
- ML20086K324 + (ML20086K324)
- ML20086K325 + (ML20086K325)
- ML20086K327 + (ML20086K327)