List of results
- ML20080D532 + (ML20080D532)
- ML20080D534 + (ML20080D534)
- ML20080D540 + (ML20080D540)
- ML20080D545 + (ML20080D545)
- ML20080D546 + (ML20080D546)
- ML20080D550 + (ML20080D550)
- ML20080D553 + (ML20080D553)
- LIC-94-0254, Forwards Certificate of Nuclear Energy Liability Insurance for American Nuclear Insurers Policy NF-207 & Maelu Policy MF-63,providing Evidence of Util Continuation of Nuclear Energy Liability Insurance Policies for CY95 + (ML20080D555)
- ML20080D558 + (ML20080D558)
- ML20080D560 + (ML20080D560)
- ML20080D570 + (ML20080D570)
- ML20080D572 + (ML20080D572)
- ML20080D574 + (ML20080D574)
- ML20080D575 + (ML20080D575)
- 0CAN129406, Informs That ANO Is Now in Compliance W/Station Blackout Rule + (ML20080D581)
- ML20080D582 + (ML20080D582)
- ML20080D586 + (ML20080D586)
- ML20080D590 + (ML20080D590)
- ML20080D592 + (ML20080D592)
- ML20080D596 + (ML20080D596)
- W3P83-2845, Forwards 830706 Rev to Seismic Qualification of Equipment Completion Schedule.Listing Summarizes Changes Occurring Since Issuance of 830601 Version,Per (W3P83-1800) + (ML20080D597)
- ML20080D603 + (ML20080D603)
- 05000263/LER-1983-018-03, /03L-0:on 830718,RHR Pump 11 Declared Inoperable Following Failure of Min Flow Valve CV1994 to Open as Required Due to Flow Switch Failure.Caused by Microswitch Contact Wear Due to flow-induced Vibration + (ML20080D606)
- ML20080D608 + (ML20080D608)
- ML20080D611 + (ML20080D611)
- ML20080D612 + (ML20080D612)
- GO2-83-761, Final & Interim Deficiency Repts Re Conditions 223 & 260 Concerning Standby Liquid Control Sys & Standby Svc Water Flow Problems.Initially Reported on 830127 & 0721.Sys Will Be Modified Per Separation Criteria.Next Rept by 831101 + (ML20080D615)
- 05000302/LER-1994-012, :on 941128,personnel Error Led to Incomplete Surveillance Resulting in Violation of Ts.Performance of Flur Surveillance to Ensure That All Relays in Tolerance + (ML20080D616)
- TXX-4032, Responds to Concerns Addressed in Draft Suppl 4 to SER Re Westinghouse D4/D5 Steam Generators.Reg Guide 1.121 Analysis of Expanded Tubes Determined Existing Plugging Criteria in Tech Specs Conservative + (ML20080D617)
- ML20080D618 + (ML20080D618)
- ML20080D620 + (ML20080D620)
- ML20080D621 + (ML20080D621)
- ML20080D622 + (ML20080D622)
- 05000260/LER-1983-049-03, /03L-0:on 830725,while Performing Surveillance Instruction 4.2.B-60,core Spray Ne Room Cooler Fan Would Not Operate.Caused by Tripped Overload Relays in Full Voltage Nonreversing Magnetic Starter.Relays Replaced + (ML20080D623)
- ML20080D629 + (ML20080D629)
- BECO-84-018, Notifies of Intent to Submit TMI Tech Specs in Aug 1984 Per NUREG-0737.Util Involved in Extensive Effort to Address Intergranular Stress Corrosion Issue During Refueling Outage + (ML20080D630)
- ML20080D631 + (ML20080D631)
- ML20080D632 + (ML20080D632)
- 05000443/LER-1994-018, :on 941128,missed TS Sr.Caused by Lack of Alarm Response Procedure for Rod Deviation Monitor Inoperable Alarm & Misunderstanding of Rod Position Data as Presented by Mpcs.Response Procedure Will Be Developed + (ML20080D633)
- ML20080D638 + (ML20080D638)
- 05000445/LER-1994-006, :on 941129,turbine Trip/Reactor Trip Due to Low Cooling Water Stator Flow Indication.For Each Condition Set of Parameters Was Selected & Examined to Confirm or Deny Condition + (ML20080D639)
- ML20080D641 + (ML20080D641)
- 05000458/LER-1994-030, :on 941204,reactor Scram Resulting from Inadvertent MSIV Isolation Due to Failure to Follow Test Procedure.Reinforced Mgt Expectations Re Personal Accountability & Procedure Compliance + (ML20080D642)
- ML20080D643 + (ML20080D643)
- 05000458/LER-1994-031, :on 941003,failure to Identify TS non- Compliance Due to Inadequate Test Procedure.Procedure Revised to Incorporate Acceptance Criteria & Provide Guidance Re Responsibilities of Personnel + (ML20080D645)
- B10872, Amend to Application for OL & Application for Amend to CPPR-113.Amend Authorizes Possession,Use & Disposition of Nuclear Matls & Reduces Ownership Share in Facility + (ML20080D646)
- ML20080D647 + (ML20080D647)
- ML20080D651 + (ML20080D651)
- ML20080D653 + (ML20080D653)
- ML20080D656 + (ML20080D656)
- BVY-94-128, Requests Exemption from Provisions of 10CFR50,App R,Section Iii.J, Emergency Lighting & Withdrawal of Previously Approved Exemption for Use of Emergency Ac Lighting in Torus Area of Reactor Bldg + (ML20080D658)