- 05000316/LER-1983-054-03, /03L-0:on 830623,during Normal Operations,Fire Door 386 Between Quad 2 & NESW Valve Gallery Failed to Latch Properly.Caused by Bent Latch Plate.Plate Removed, Straightened & Reinstalled + (ML20077A760)
- 05000382/LER-1994-014-01, :on 941006,HLIV Circuit Breaker Left in Open Position Due to Personnel Error.Cognizant CRS Has Been Counseled in Accordance W/Waterford 3 Improving Human Performance Program + (ML20077A763)
- 05000389/LER-1983-029-03, /03L-0:on 830610,while Performing Power Ascension Testing,Auxiliary Feedwater Pump C Failed to Reach Rated Speed.Caused by Erroneous Electrical Overspeed Trips Due to Noise Seen by Air Pax Series 300 Tachometer + (ML20077A767)
- 05000293/LER-1980-034, Updated LER 80-034/03X-1:on 800701 & 16,HPCI Turbine Discharge Line Snubber Found Severed & HPCI Declared Inoperable.Caused by Transient Hydrodynamic Shock During Startup & Shutdown of HPCI Turbine + (ML20077A769)
- ML20077A775 + (ML20077A775)
- ML20077A779 + (ML20077A779)
- 05000259/LER-1983-030-03, /03L-0:on 830612,during Refueling Outage,Stack Gas Sample Pump B Tripped Making Both Stack Monitoring Channels Inoperable.Caused by Overcurrent.Pump B Replaced.Failures Being Investigated + (ML20077A781)
- ML20077A782 + (ML20077A782)
- 05000259/LER-1983-032-03, /03L-0:on 830612,during Refueling Outage,Trouble Alarm Came in for Control Bay Elevation 593 Fire Protection Panel 1-25-325,zone 14.Caused by Power Loss to Some Smoke Detectors Due to Loose Wires + (ML20077A785)
- 05000382/LER-1994-015-01, :on 940916,boric Acid Addition to RCS Occurred. Caused by Personnel Error Due to Lack of Self Checking. Primary Nuclear Plant Operator Counseled Re Improving Human Performance Program + (ML20077A789)
- 05000334/LER-1983-002-03, 138-kV Bus 1 Lost.Caused by Inadvertent Operation of Bus back-up Timer Relay 62-Z41. Sbfu & Sru Relays Interchanged,Sbfu Relays Modified & Physical Barrier Around Sbfu Switch Installed + (ML20077A791)
- ML20077A793 + (ML20077A793)
- ML20077A799 + (ML20077A799)
- ML20077A806 + (ML20077A806)
- ML20077A807 + (ML20077A807)
- ML20077A811 + (ML20077A811)
- 05000395/LER-1983-061-03, /03L-0:on 830610,identified Surveillance Requirements for 6-inch Containment Purge Supply & Exhaust Isolation Valves Not Fully Conducted.Caused by Procedural Inadequacy.Procedure Developed + (ML20077A813)
- ML20077A820 + (ML20077A820)
- 05000387/LER-1983-091-03, /03L-0:on 830609,LPCI Loop B of RHR Discovered Not Full.Lpci Declared Inoperable.Caused by Loose LPCI Control Disc Valve.Tack Weld on Disc/Stem Assembly Increased + (ML20077A824)
- ML20077A827 + (ML20077A827)
- ML20077A830 + (ML20077A830)
- ML20077A835 + (ML20077A835)
- ML20077A839 + (ML20077A839)
- 05000277/LER-1983-019-03, /03L-0:on 830626,during Surveillance Testing, Standby Gas Treatment Filter Train Outlet Valve AO-20475-2 Failed to Open.Caused by Binding in Solenoid Valve Mfg by Asco.Solenoid Replaced & Valve Returned to Svc + (ML20077A841)
- 05000277/LER-1983-018-03, /03L-0:on 830624,while Performing HPCI Sys Logic Functional Surveillance Test,Hpci Turbine Control Valve Failed to Open.Caused by Burned Out Dropping Resistor in Power Supply to Woodward Emergency Generator Motor + (ML20077A848)
- ML20077A851 + (ML20077A851)
- ML20077A856 + (ML20077A856)
- ML20077A861 + (ML20077A861)
- ML20077A863 + (ML20077A863)
- 05000250/LER-1983-008-03, /03L-0:on 830614,conduit for Future Safety Parameter Display Sys Accidentally Damaged During Installation.One Containment Spray Pump Involved.Caused by Incorrect Drawing.Repairs Initiated + (ML20077A869)
- ML20077A885 + (ML20077A885)
- PLA-1748, Second Interim Part 21 Rept Re Inadequacies in Bechtel Design Verification of Max Circuit Lengths of Low Voltage Power & Control Cables.Initially Reported on 821215.Next Rept by 831031 + (ML20077A888)
- ML20077A890 + (ML20077A890)
- BECO-94-128, Application for Amend to License DPR-35,revising Suppression Chamber Water Level Operating Range,Increasing & Revises Water Level Recorder Range in Response to Commitment from Insp 50-293/91-201 + (ML20077A893)
- ML20077A894 + (ML20077A894)
- ML20077A896 + (ML20077A896)
- ML20077A899 + (ML20077A899)
- ML20077A900 + (ML20077A900)
- ML20077A912 + (ML20077A912)
- NG-94-3575, Request for TS Change (RTS-267),replacing Instrument Setpoint W/Ref to Appropriate Citation in Offsite Dose Assessment Manual & Modifying Operability Requirement & Required Action for Inoperable Offgas Vent Stack RMs + (ML20077A913)
- ML20077A919 + (ML20077A919)
- ML20077A926 + (ML20077A926)
- ML20077A938 + (ML20077A938)
- ML20077A939 + (ML20077A939)
- AECM-83-0330, Submits Supplemental Response to NRC Re Violations Noted in IE Insp Rept 50-416/82-78.Corrective Actions:Security Post Established to Conduct Insps of Control Room Cabinets Every 4 H & All Activities Logged + (ML20077A941)
- ML20077A946 + (ML20077A946)
- ML20077A954 + (ML20077A954)
- AECM-83-0165, Forwards Response to NRC Re Violations Noted in IE Insp Rept 50-416/82-78.Corrective Actions:Surveillance Conducted on 821125,w/independent Verification.Valves Positioned & Locked Per Instructions.Training Scheduled + (ML20077A956)
- ML20077A974 + (ML20077A974)
- ML20077A978 + (ML20077A978)
- 0CAN068317, Responds to Request for Addl Info Re Violation Noted in IE Insp Rept 50-313/83-03 Concerning Failure to Follow Requirements for Changes to Refueling Shuttle Procedure. Procedure Modified to Detail Sequence Changes + (ML20077A995)