ML20077A793

From kanterella
Jump to navigation Jump to search
Forwards Rev 0 to NSP Prairie Island Nuclear Generating Plant Unit 2 ISI Exam Plan Third Interval 941221-201220, 2004
ML20077A793
Person / Time
Site: Prairie Island 
Issue date: 11/15/1994
From: Richard Anderson
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20077A796 List:
References
NUDOCS 9411250239
Download: ML20077A793 (2)


Text

Northern States Power Company Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East Welch, Minnesota 55089 November 15, 1994 10 CFR Part 50

  • ection 50.55a(g)

L U S Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISIAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Submittal of the 3rd 10-Year Inservice Inspection Exc.mination Plan. Revision 0 to the Reauirements of ASME Section XI Attached is the ASME Code Section XI Inservice Inspection Examination Plan, Revision 0, for the third ten-year interval for Unit 2 of the Frairie Island Nuclear Generating Plant. Requests for relief, included in thic program, are being submitted for NRC review and approval in accordance wit.h 10 CFR Part 50, Section 50.55a.

The program has generally been developed to ASME Section XI,1989 Npion.

For det,.ils, see the Introduction (Pages 2-1 and 2-2) to the Plan. The 3rd Interval officially bagins December 21, 1994 but inspections will not be performed per the new plan until the reiueling outage scheduled to begin in May 1995. Request for Relief #1 is the only one requiring approval by May 1995 since we will not be performing inspections addressed by any of the other relief requests during 1995.

We will provide you with revisions to the Inservice Inspection Examination Plan for information when significant revisions have been incorporated (e.g.,

the addition of new components because of a significant modification to the plant).

Future Requests for Relief will be submitted as the need occurs.

(

9411550239 h h o6 pqR ADOCK PDR lk u

i k

,(:

I

'1 UL NRC NORTHERN STATES POWER COMPANY l

November 15, 1994' Page 2

]

i i

r i

Please contact Jack Leveille (612-388-1121, Ext. 4662) if you have any questions related to this letter.

'l Y

f

[^

Roger O Anderson j

Director Licensing and Management Issues.

I c: Regional Administrator - Region III, NRC Senior Resident Inspector, NRC NRR Project Manager, NRC i

J E Silberg A S Jimenez (Hartford)

Bob Kubitschek (State of Minnesota)

Attachments:

INSERVICE INSPECTION EXAMINATION PLAN, REVISION O

{

t f

i l

)

l i

I i

i

{

i l

r t

f I

isisub.u2 I

i b

, _ _ _ _. _ -. _ ~

.. -, !