- 05000249/LER-1983-004-03, /03L-0:on 830204,while Disc Operations Sys 1600-1 Valve Timing Test in progress,MO-3-1301-3 Failed to Open. Caused by Valve Disc Wedged Too Tightly Against Seat.Valve Cycled from Control & Successfully Timed + (ML20071C787)
- ML20071C791 + (ML20071C791)
- 05000315/LER-1983-002, Forwards LER 83-002/03L-0 + (ML20071C792)
- ML20071C794 + (ML20071C794)
- ML20071C795 + (ML20071C795)
- ML20071C797 + (ML20071C797)
- 05000315/LER-1983-002-03, /03L-0:on 830125,ice Condenser Intermediate Deck Door Weighing Procedure Revealed 70 Doors Exceeded Max Initial Opening Force Specs.Caused by Misalignment &/Or Dented Hinges.Hinges Realigned & Lubricated + (ML20071C801)
- ML20071C802 + (ML20071C802)
- 05000305/LER-1983-002, Forwards LER 83-002/03L-0 + (ML20071C810)
- ML20071C815 + (ML20071C815)
- 05000305/LER-1983-002-03, /03L-0:on 830126,during Full Power,Diesel Generator Removed from Svc to Repair Leaks in Cooling Sys Hx.Caused by Corrosion on Svc Water Side of Cooling Water Hx.Two Tubes Plugged & Four Tube Sheet Faces Repaired + (ML20071C818)
- ML20071C819 + (ML20071C819)
- ML20071C823 + (ML20071C823)
- ML20071C826 + (ML20071C826)
- ML20071C828 + (ML20071C828)
- ML20071C830 + (ML20071C830)
- ML20071C835 + (ML20071C835)
- ML20071C836 + (ML20071C836)
- ML20071C842 + (ML20071C842)
- ML20071C844 + (ML20071C844)
- ML20071C846 + (ML20071C846)
- ML20071C849 + (ML20071C849)
- ML20071C851 + (ML20071C851)
- ML20071C853 + (ML20071C853)
- ML20071C857 + (ML20071C857)
- ML20071C858 + (ML20071C858)
- ML20071C861 + (ML20071C861)
- ML20071C863 + (ML20071C863)
- TXX-3624, Final Deficiency Rept Re Procurement & Installation of Nonmetallic Insulation.Initially Reported on 830126.Matter Not Reportable Per 10CFR50.55(e) + (ML20071C865)
- ML20071C867 + (ML20071C867)
- W3P83-0654, First Interim Significant Const Deficiency Rept 69 Re Crosby Valve & Gage Co Stellite Alloy 6B Discs.Discs Will Be Replaced W/Certified Matl.Next Rept Will Be Submitted by 830510 + (ML20071C870)
- ML20071C873 + (ML20071C873)
- 05000255/LER-1983-009-03, /03L-0:on 830127,PCS Sample Revealed Dose Equivalent I-131 Exceeded Tech Specs.Caused by Normal Fuel Leakage.Procedures to Be Revised to Increase Letdown Purification Flow Following Trip + (ML20071C874)
- ML20071C875 + (ML20071C875)
- ML20071C876 + (ML20071C876)
- ML20071C878 + (ML20071C878)
- ML20071C879 + (ML20071C879)
- 05000321/LER-1981-136, Forwards Updated LER 81-136/03X-1 + (ML20071C880)
- ML20071C882 + (ML20071C882)
- ML20071C884 + (ML20071C884)
- 05000321/LER-1981-136-03, Both off-gas Hydrogen Analyzers Found Inoperable.Caused by Component Failure. Analyzer a Found Out of Calibr.Analyzer a Recalibr & Returned to Svc.Pumps Replaced on Analyzer B + (ML20071C886)
- ML20071C888 + (ML20071C888)
- ML20071C889 + (ML20071C889)
- 05000255/LER-1983-012, Forwards LER 83-012/03L-0 + (ML20071C890)
- 05000255/LER-1983-012-03, /03L-0:on 830130,sample from T-82D (Safety Injection Tank D) Showed Boron Concentration Below Tech Spec Limit of 1,720 Ppm.Caused by Boron Dilution Due to Minor Leak Past Check Valve.Primary Coolant Leak Rate Monitored + (ML20071C897)
- ML20071C899 + (ML20071C899)
- ML20071C901 + (ML20071C901)
- ML20071C902 + (ML20071C902)
- ML20071C903 + (ML20071C903)
- 05000373/LER-1983-006-03, /03L-0:on 830202,steam Observed Leaking from MSIV,1B21-F028A,due to Two Cracks 180 Degrees Apart in Weld Where 1MS20AA-2-inch Drain Line Attached to Valve Body. Caused by Improper Weld Application.Weld Repaired + (ML20071C904)
- 05000254/LER-1983-006, Forwards LER 83-006/03L-0 + (ML20071C905)