- ML20058E079 + (ML20058E079)
- 05000361/LER-1982-028-03, /03L-0:on 820612,switch on Discharge Valve 2HV4731 Found Inoperable,Rendering Motor Driven Auxiliary Pump 2P-141 Inoperable.Caused by Binding Valve.Valves Stroked + (ML20058E080)
- ML20058E081 + (ML20058E081)
- 05000344/LER-1990-040, :on 900929,intermittent Failure of Containment Monitoring Sys Process & Effluent Radiation Monitor Iodine Occurred + (ML20058E082)
- ML20058E085 + (ML20058E085)
- ML20058E086 + (ML20058E086)
- ML20058E087 + (ML20058E087)
- ML20058E088 + (ML20058E088)
- ML20058E089 + (ML20058E089)
- 05000413/LER-1989-027, :on 891120,Tech Spec Required Unit Shutdown Due to Inoperable Chemical & Vol Control Centrifugal Pump.W/ + (ML20058E091)
- ML20058E092 + (ML20058E092)
- ML20058E093 + (ML20058E093)
- ML20058E094 + (ML20058E094)
- ML20058E095 + (ML20058E095)
- ML20058E098 + (ML20058E098)
- 05000361/LER-1982-029-03, /03L-0:on 820612,switch on Discharge Valve 2HV4714 Found Inoperable,Rendering Motor Driven Auxiliary Pump 2P-504 Inoperable.Caused by Binding Valve.Valves Stroked + (ML20058E099)
- ML20058E102 + (ML20058E102)
- ML20058E104 + (ML20058E104)
- 05000361/LER-1982-030-03, /03L-0:on 820612,electrohydraulic Valve 2HV4714 Failed to Open,Rendering Motor Driven Auxiliary Pump 2P-504 Inoperable.Cause Not Determined.Valve Disassembled & Rebuilt + (ML20058E108)
- 05000498/LER-1990-023, :on 900929,manual RT Due to Full Closure of FW Isolation Valve During Partial Stroke Test + (ML20058E109)
- ML20058E111 + (ML20058E111)
- IR 05000266/1982015 + (ML20058E112)
- ML20058E114 + (ML20058E114)
- ML20058E117 + (ML20058E117)
- 05000361/LER-1982-031-03, /03L-0:on 820616,discovered Oil Leakage from Bearings of Auxiliary Feedwater Drive Pump 2P-504.Caused by Bearing Failure.Leakage Repaired + (ML20058E118)
- ML20058E119 + (ML20058E119)
- 05000321/LER-1990-020, :on 901006,main Turbine High Vibrations Result in Automatic Scram + (ML20058E120)
- ML20058E121 + (ML20058E121)
- ML20058E122 + (ML20058E122)
- ML20058E127 + (ML20058E127)
- 05000361/LER-1982-032-03, /03L-0:on 820617,vent Valve S21305MR807 Broke Off, Creating 1-inch Diameter Leakage.Caused by Fatigue Failure Due to Hydraulic Instability.Valve & Portion of Piping Replaced + (ML20058E128)
- 05000285/LER-1990-024, :on 901026,discovered Failure to Conduct Hourly Firewatch + (ML20058E129)
- ML20058E130 + (ML20058E130)
- ML20058E131 + (ML20058E131)
- ML20058E132 + (ML20058E132)
- 05000483/LER-1990-011, :on 901003,ESF Actuations Occurred Due to Spurious Signal on Fuel Bldg Radiation Monitor + (ML20058E133)
- ML20058E134 + (ML20058E134)
- LD-90-083, Forwards Amend H to CESSAR - Design Certification + (ML20058E135)
- ML20058E137 + (ML20058E137)
- ML20058E139 + (ML20058E139)
- ML20058E140 + (ML20058E140)
- IR 05000247/1993026 + (ML20058E141)
- ML20058E143 + (ML20058E143)
- ML20058E147 + (ML20058E147)
- ML20058E148 + (ML20058E148)
- ML20058E149 + (ML20058E149)
- ML20058E151 + (ML20058E151)
- ML20058E153 + (ML20058E153)