- 05000206/LER-1982-009-01, /01T-0:on 820405,failed Attachment Welds on Four Feedwater Sys Pipe Supports Discovered During Scheduled Insp.Cause Undetermined.Metallurgical & Design Analysis in Progress.Failed Supports Being Replaced + (ML20054D089)
- ML20054D090 + (ML20054D090)
- ML20054D092 + (ML20054D092)
- 05000305/LER-1982-004-03, /03L-0:on 820308,valve SI 200B Failed to Close During RHR Pump & Valve Testing.Cause Unknown.Valve Closed Manually.Multiple Cycling from Control Room Revealed No Further Difficulties + (ML20054D094)
- ML20054D095 + (ML20054D095)
- ML20054D096 + (ML20054D096)
- ML20054D098 + (ML20054D098)
- IR 05000409/1982003 + (ML20054D099)
- ML20054D100 + (ML20054D100)
- 05000305/LER-1982-005-03, /03L-0:on 820309,1A2 Svc Water Pump Failed to Start on Demand During Quarterly Surveillance Testing of Svc Water Pumps.Caused by Failure of Circuit to Close Due to Failed Open Closing Coil.Coil Replaced + (ML20054D101)
- A02315, Advises That NRC Evaluation of SEP Topic IV-3, BWR Jet Pump Operating Indications, Factually Correct.Util Has No Comment + (ML20054D102)
- ML20054D103 + (ML20054D103)
- ML20054D104 + (ML20054D104)
- ML20054D106 + (ML20054D106)
- ML20054D107 + (ML20054D107)
- ML20054D108 + (ML20054D108)
- 05000316/LER-1982-021, Forwards LER 82-021/03L-0 + (ML20054D109)
- ML20054D111 + (ML20054D111)
- IR 05000483/1982001 + (ML20054D113)
- 05000133/LER-1982-003, Forwards LER 82-003/03L-0 + (ML20054D115)
- 05000316/LER-1982-021-03, /03L-0:on 820315,while in Mode 5,surveillance Testing of ESF Ventilation Sys Filter Train (HV-AES-2) Revealed One HEPA Filter Did Not Meet Air Flow Distribution Criteria.New Filters Installed + (ML20054D117)
- ML20054D119 + (ML20054D119)
- ML20054D121 + (ML20054D121)
- ML20054D122 + (ML20054D122)
- 05000311/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl + (ML20054D123)
- ML20054D125 + (ML20054D125)
- IR 05000461/1981024 + (ML20054D126)
- ML20054D128 + (ML20054D128)
- AECM-82-158, Forwards Addl Info Re Independency of Cygna Energy Svcs & Bechtel.No Vested Interest in Design Control Scheme for Reactor Facility Determined + (ML20054D130)
- 05000133/LER-1982-003-03, /03L-0:on 820319,w/unit Shutdown,Ground Detected at Fire Pump 3 Motor.Caused by Defective Stator Due to Age & Deterioration.Stator Rewound.Preventive Maint Schedule Will Be Established + (ML20054D131)
- 05000311/LER-1982-021-03, /03L-0:on 820320,while Performing Surveillance Procedure SP(O)4.6.1.3 on 100 Ft Elevation Containment Air Lock,Leakage Rate Exceeded Limit of 0.05 La at Design Pressure of 47.0 Psig.Caused by Loose Chain on Inner Door + (ML20054D132)
- IR 05000346/1982003 + (ML20054D134)
- 05000309/LER-1982-014, Forwards LER 82-014/03L-0 + (ML20054D135)
- 05000272/LER-1981-120, Forwards LER 81-120/03X-1.Detailed Event Analysis Encl + (ML20054D137)
- ML20054D139 + (ML20054D139)
- ML20054D143 + (ML20054D143)
- ML20054D144 + (ML20054D144)
- ML20054D145 + (ML20054D145)
- ML20054D146 + (ML20054D146)
- 05000272/LER-1982-011, Forwards LER 82-011/03X-1.Detailed Event Analysis Encl + (ML20054D147)
- ML20054D149 + (ML20054D149)
- AECM-82-173, Forwards Addl Info Requested by Equipment Qualification Branch Re Justification for Interim Operation for Equipment Not Qualified to Seismic Qualification Review Team Criteria + (ML20054D150)
- ML20054D151 + (ML20054D151)
- 05000309/LER-1982-014-03, /03L-0:on 820326,during Start of Plant Heatup, Station Technical Advisor Was Not at Required Station for Period of 7-h.Caused by Misconception on Part of Assigned Personnel.Station Technical Assistants Advised of Procedure + (ML20054D156)
- ML20054D157 + (ML20054D157)
- 05000315/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20054D159)
- 05000266/LER-1982-007-01, /01T-0:on 820329,during secondary-to-primary Leak Check,Two Leaking Tubes in a Steam Generator & 28 Defective Tubes in a & B Steam Generators Discovered.Caused by Caustic.All Defective & Leaking Tubes Plugged + (ML20054D161)
- ML20054D162 + (ML20054D162)
- 05000155/LER-1982-013, Forwards LER 82-013/01T-0 + (ML20054D163)
- ML20054D165 + (ML20054D165)
- 05000155/LER-1982-013-01, /01T-0:on 820328,during Drainage of Primary Sys Water Level,Steam Drum Level Indication Failed to Register Proper Water Level.Caused by Inadequate Procedure Re Filling Level Transmitter Ref Lines.Procedures Will Be Revised + (ML20054D166)