- 05000251/LER-1982-004, Forwards LER 82-004/01T-0 + (ML20052C272)
- IR 05000395/1982023 + (ML20052C274)
- ML20052C275 + (ML20052C275)
- ML20052C276 + (ML20052C276)
- IR 05000250/1982013 + (ML20052C277)
- PNO-V-82-014F, on 820426,util Completed Replacement of a & B HPI Thermal Sleeves & safe-end Nozzles.Critical Path Schedule for Resumption of Operation Dependent on Repair of Steam Generator Auxiliary Feedwater Headers + (ML20052C278)
- ML20052C280 + (ML20052C280)
- ML20052C284 + (ML20052C284)
- ML20052C286 + (ML20052C286)
- ML20052C287 + (ML20052C287)
- ML20052C288 + (ML20052C288)
- ML20052C290 + (ML20052C290)
- ML20052C291 + (ML20052C291)
- 05000251/LER-1982-004-01, /01T-0:on 820408,while Operating at Full Power, Routine Sample Analysis Found Boron Concentration in Boron Injection Tank Lower than Tech Specs.Caused by Boric Acid Obstructing Flow Path.Line Flushed W/Steam + (ML20052C294)
- ML20052C298 + (ML20052C298)
- ML20052C300 + (ML20052C300)
- ML20052C302 + (ML20052C302)
- ML20052C304 + (ML20052C304)
- 05000333/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20052C309)
- ML20052C312 + (ML20052C312)
- 05000368/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20052C315)
- 05000333/LER-1982-016-03, /03L-0:on 820329,reactor Core Isolation Cooling Sys Was Intentionally Made Inoperable to Allow Repair of Dc Ground on Sys Logic Circuits.Ground Caused by Failed Sump Pump Which Allowed Valve Pit Flooding.Pump Replaced + (ML20052C317)
- IR 05000344/1982014 + (ML20052C318)
- 05000272/LER-1982-022, Forwards LER 82-022/03L-0.Detailed Event Analysis Encl + (ML20052C321)
- 05000368/LER-1982-009-03, /03L-0:on 820401,control Element Assembly Calculator 2 Failed During Performance of ex-core Instrument Test on Channel D.Caused by Computer Scan Inconsistency. Penalties Applied & Indication Returned to Normal + (ML20052C323)
- ML20052C324 + (ML20052C324)
- 05000317/LER-1982-015, Forwards LER 82-015/03L-0 + (ML20052C326)
- IR 05000141/1982001 + (ML20052C328)
- 05000313/LER-1982-007, Forwards LER 82-007/03L-0 + (ML20052C329)
- ML20052C331 + (ML20052C331)
- 05000272/LER-1982-022-03, /03L-0:on 820405,svc Water Flow 14 Containment Fan Coil Unit Was Less than 700 Gpm Required.Caused by Decrease in Output Flow Control Valve 14SW57 High Speed Air Supply. Regulator Blown Down & Setpoint Readjusted + (ML20052C333)
- ML20052C334 + (ML20052C334)
- 05000313/LER-1982-007-03, /03L-0:on 820324,surveillance Revealed That Anticipatory Reactor Trip Main Feedwater Pump & Turbine Tripped Bypass Setpoints Exceeded Tech Spec Limits.Caused by Inadequate Review & Implementation Procedures + (ML20052C336)
- 05000317/LER-1982-015-03, /03L-0:on 820407,during Normal Operation,While Performing Maint on Pressure Transmitter 102C,pressurizer Level Exceeded Tech Specs.Caused by Personnel Failure to Realize Commonality of Ref Legs + (ML20052C339)
- ML20052C340 + (ML20052C340)
- 05000254/LER-1982-005, Forwards LER 82-005/03L-0 + (ML20052C343)
- 05000254/LER-1982-005-03, /03L-0:on 820325,reactor Core Isolation Cooling Sys Failed to Operate During Monthly Test Qos 1300-2.Caused by Ground in Logic Circuit Initiating Low Voltage at Electrical Overspeed Trip Sensor + (ML20052C346)
- ML20052C347 + (ML20052C347)
- ML20052C350 + (ML20052C350)
- ML20052C351 + (ML20052C351)
- ML20052C353 + (ML20052C353)
- IR 05000400/1982009 + (ML20052C354)
- PNO-IV-82-016, on 820426,pressure Between Helium & Water in Bearing Water Sys Forced Radioactive Coolant (Helium) Down One Shaft,Resulting in Unplanned Release of Radioactive Gases.No Significant Radiation Exposure + (ML20052C355)
- ML20052C357 + (ML20052C357)
- IR 05000250/1982015 + (ML20052C358)
- ML20052C359 + (ML20052C359)
- ML20052C361 + (ML20052C361)
- ML20052C362 + (ML20052C362)
- ML20052C364 + (ML20052C364)
- ML20052C368 + (ML20052C368)
- ML20052C373 + (ML20052C373)