Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20042A684 + (ML20042A684)
- IR 05000546/1982001 + (ML20042A686)
- ML20042A687 + (ML20042A687)
- 05000220/LER-1982-007-04, /04L-0:on 820222,while Reviewing Environ Radiation Fish Analysis Sample Data,Lower Limit of Detection Sensitivity Was Determined Not Met for Nov 1981.Cause Not Stated.Tech Spec Proposal Being Submitted to Update Stds + (ML20042A689)
- ML20042A690 + (ML20042A690)
- IR 05000461/1982003 + (ML20042A692)
- 05000324/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20042A693)
- ML20042A697 + (ML20042A697)
- ML20042A698 + (ML20042A698)
- ML20042A699 + (ML20042A699)
- ML20042A700 + (ML20042A700)
- 05000324/LER-1982-016-03, /03L-0:on 820214,during Plant Operation,Reactor Recirculation Pump Tripped.Caused by Accidental Dropping of RTGB On/Off Indication Lights for Pump Motor Generator Set Drive Motor Power Supply Breaker Into Module Socket + (ML20042A701)
- ML20042A702 + (ML20042A702)
- ML20042A704 + (ML20042A704)
- ML20042A706 + (ML20042A706)
- IR 05000313/1982001 + (ML20042A707)
- ML20042A708 + (ML20042A708)
- ML20042A709 + (ML20042A709)
- 05000293/LER-1982-004-01, /01T-0:on 820222,during Refuel/Mod Outage, Determined That Test Points on 20-inch Vent & Purge Butterfy Valve Flanges Were Not Type B Tested.Caused by Procedural Inadequacy.Procedures Revised + (ML20042A710)
- PNO-I-82-023A, on 820310,after Replacing All Studs on Steam Generator 2 Cold Leg Manway,Nondestructive Exam Determined Four Studs Cracked.Small Leak Detected from Reactor Vessel Head Seal + (ML20042A711)
- ML20042A712 + (ML20042A712)
- ML20042A713 + (ML20042A713)
- ML20042A715 + (ML20042A715)
- ML20042A716 + (ML20042A716)
- ML20042A718 + (ML20042A718)
- ML20042A720 + (ML20042A720)
- ML20042A721 + (ML20042A721)
- ML20042A723 + (ML20042A723)
- ML20042A725 + (ML20042A725)
- 0CAN038204, Advises of Current Status of Util Efforts to Comply w/820115 Request for Addl Info Re IE Bulletin 80-11, Masonry Wall Design. Response Will Be Provided by 820430,should No Unforeseen Problems Arise + (ML20042A726)
- ML20042A727 + (ML20042A727)
- IR 05000454/1982003 + (ML20042A728)
- ML20042A729 + (ML20042A729)
- ML20042A730 + (ML20042A730)
- ML20042A731 + (ML20042A731)
- ML20042A733 + (ML20042A733)
- ML20042A734 + (ML20042A734)
- 05000293/LER-1982-005, Forwards LER 82-005/01T-0.Detailed Event Analysis Encl + (ML20042A736)
- ML20042A738 + (ML20042A738)
- ML20042A739 + (ML20042A739)
- ML20042A740 + (ML20042A740)
- ML20042A741 + (ML20042A741)
- ML20042A744 + (ML20042A744)
- 05000293/LER-1982-005-01, /01T-0:on 820226,deficiencies in Pipe Supports in Control Rod Driveline Insert & Withdraw Lines Identified. Caused by Missing or Loose Clamps.Restoration to Acceptable Limits Will Be Completed Before End of Cycle VI + (ML20042A746)
- 05000237/LER-1982-006, Forwards LER 82-006/03L-0 + (ML20042A747)
- ML20042A749 + (ML20042A749)
- 05000339/LER-1982-006, Forwards LER 82-006/03L-0 + (ML20042A751)
- 05000339/LER-1982-006-03, /03L-0:on 820216,during Mode 1 Operation,B Quench Spray Subsystem Removed from Svc Contrary to Tech Specs. Subsystem Removed from Svc to Repair body-to-bonnet Leak on B Quench Spray Pump Suction valve,MOV-QS-200B + (ML20042A753)
- 05000237/LER-1982-006-03, /03L-0:on 820210,ATWS Div II High Pressure Transmitter 2-263-20D,read Offscale High & Tripped Light on Panel 2202-70B.Caused by Faulty Capacitor in Amplifier Circuit Board.Amplifier Circuit Board Replaced + (ML20042A754)
- ML20042A755 + (ML20042A755)
- ML20042A756 + (ML20042A756)