- ML20042A095 + (ML20042A095)
- ML20042A096 + (ML20042A096)
- ML20042A097 + (ML20042A097)
- IR 05000003/1978004 + (ML20042A099)
- IR 05000003/1977013 + (ML20042A100)
- IR 05000003/1977016 + (ML20042A101)
- 05000245/LER-1982-004, Forwards LER 82-004/03L-0.Detailed Event Analysis Encl + (ML20042A102)
- IR 05000003/1978001 + (ML20042A104)
- 05000245/LER-1982-004-03, /03L-0:on 820212,during Containment Isolation Valve Operability Demonstration,Isolation Condenser Condensate Return Valve 1-IC-3 Failed to Open Upon Signal. Caused by Contraction Upon Cooling.Valve Heated to Open + (ML20042A105)
- 05000219/LER-1982-010, Forwards LER 82-010/01T-0.Detailed Event Analysis Encl + (ML20042A106)
- ML20042A110 + (ML20042A110)
- ML20042A111 + (ML20042A111)
- 05000219/LER-1982-010-01, /01T-0:on 820218,deluge Sys for Reactor Bldg Elevation 51 Ft Actuated Due to Smoke from Overheated Bearing in Cleanup Sys Auxiliary Pump Motor.Caused by Inadequate Electrical Sealing Techniques + (ML20042A113)
- ML20042A114 + (ML20042A114)
- ML20042A115 + (ML20042A115)
- 05000318/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20042A117)
- ML20042A120 + (ML20042A120)
- 05000318/LER-1982-009-03, /03L-0:on 820206 & 25,pressurizer Level Exceeded Tech Spec Requirements During Normal Startup Operations. Caused by Normal RCS Temp Swings.Investigation to Relax Limit Underway + (ML20042A123)
- ML20042A124 + (ML20042A124)
- IR 05000334/1981031 + (ML20042A125)
- ML20042A127 + (ML20042A127)
- ML20042A129 + (ML20042A129)
- ML20042A130 + (ML20042A130)
- ML20042A131 + (ML20042A131)
- ML20042A132 + (ML20042A132)
- ML20042A134 + (ML20042A134)
- ML20042A135 + (ML20042A135)
- ML20042A137 + (ML20042A137)
- ML20042A138 + (ML20042A138)
- ML20042A139 + (ML20042A139)
- ML20042A140 + (ML20042A140)
- ML20042A142 + (ML20042A142)
- ML20042A143 + (ML20042A143)
- ML20042A145 + (ML20042A145)
- ML20042A146 + (ML20042A146)
- ML20042A147 + (ML20042A147)
- ML20042A149 + (ML20042A149)
- ML20042A150 + (ML20042A150)
- ML20042A152 + (ML20042A152)
- ML20042A153 + (ML20042A153)
- B10447, Final Significant Deficiency Rept SD-9 Re Main Feedline Rupture W/Failure of Blowdown Sys.Design Modified to Include Cavitating Venturies to Preclude Uncontrollable Auxiliary Feedwater Flows to Faulted Steam Generator + (ML20042A154)
- ML20042A156 + (ML20042A156)
- ML20042A157 + (ML20042A157)
- ML20042A158 + (ML20042A158)
- ML20042A159 + (ML20042A159)
- ML20042A160 + (ML20042A160)
- ML20042A161 + (ML20042A161)
- 05000277/LER-1982-004-03, /03L-0:on 820206,during Surveillance Testing of Primary Containment Isolation Sys,Standby Gas Treatment Filter a Inlet Damper Failed to Automatically Open.Caused by Defective Damper Control Switch.Switch Replaced + (ML20042A162)
- ML20042A163 + (ML20042A163)
- ML20042A164 + (ML20042A164)
- 05000277/LER-1982-003-03, /03L-0:on 820129,during Power Operation,Diesel Generator Cardox Tank Level Dropped Below Tech Spec Limit. Caused by Stuck Level Indicator Float Mechanism (Cardox P/N 124109),due to Ice.Float Replaced & Sys Blown Down + (ML20042A169)