Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20012C655 + (ML20012C655)
- ML20012C656 + (ML20012C656)
- PNO-III-90-018, on 900315,District Court Judge Denied Kerr- Mcgee Request for Injunction Re Excavation Permit.On 900314, Dupage County Judge Issued Temporary Restraining Order Prohibiting Kerr-McGee Beginning Const of Disposal Cell + (ML20012C657)
- ML20012C658 + (ML20012C658)
- ML20012C659 + (ML20012C659)
- ML20012C661 + (ML20012C661)
- ML20012C662 + (ML20012C662)
- ML20012C663 + (ML20012C663)
- IR 05000263/1990003 + (ML20012C664)
- ML20012C666 + (ML20012C666)
- ML20012C667 + (ML20012C667)
- ML20012C668 + (ML20012C668)
- ML20012C669 + (ML20012C669)
- ML20012C670 + (ML20012C670)
- ML20012C671 + (ML20012C671)
- ML20012C673 + (ML20012C673)
- ML20012C674 + (ML20012C674)
- ML20012C675 + (ML20012C675)
- ML20012C676 + (ML20012C676)
- ML20012C678 + (ML20012C678)
- ML20012C679 + (ML20012C679)
- 05000311/LER-1990-010, :on 900216,containment Radioactive Iodine Monitor Radiation Monitoring Sys Channel Failed Low.Caused by Design/Equipment Concerns.Sys Design Mods Will Be Implemented to Eliminate ESF Actuation Signals + (ML20012C681)
- ML20012C683 + (ML20012C683)
- ML20012C684 + (ML20012C684)
- IR 015000033/1990001 + (ML20012C685)
- ML20012C686 + (ML20012C686)
- ML20012C687 + (ML20012C687)
- 05000413/LER-1990-011, :on 900215,discovered That Control Room Doors Were More Difficult to Open than Normal.Ventilation Sys Found to Be Incapable of Maintaining Positive Pressure. Caused by Design Deficiency.Walls Sealed + (ML20012C688)
- ML20012C689 + (ML20012C689)
- 05000413/LER-1990-005, :on 900126,Tech Spec 3.0,3 Entered Due to More than One Power Range Nuclear Instrumentation Channel Exceeding 5% Deviation.Caused by Mgt Deficiency.Operations Procedure Revised + (ML20012C690)
- ML20012C691 + (ML20012C691)
- ML20012C692 + (ML20012C692)
- NLS9000107, Submits Final Response to Generic Ltr 88-14, Instrument Air Supply Problems Affecting Safety-Related Equipment. Final Item,Verification That Mfg Air Quality Requirements for Essential Components,Completed + (ML20012C693)
- ML20012C694 + (ML20012C694)
- NLS9000108, Notifies NRC of Intent to Defer Response to Generic Ltr 89-19,per 900306 Approved Scheduler Extension.Response Will Be Submitted on or Before 900504 + (ML20012C695)
- ML20012C696 + (ML20012C696)
- ML20012C697 + (ML20012C697)
- ML20012C698 + (ML20012C698)
- ML20012C699 + (ML20012C699)
- ML20012C700 + (ML20012C700)
- ML20012C701 + (ML20012C701)
- ML20012C702 + (ML20012C702)
- ML20012C703 + (ML20012C703)
- ML20012C705 + (ML20012C705)
- 05000352/LER-1990-003-01, :on 900208,HPCI Sys Inboard Isolation Valve Inadvertently Isolated & Closed When One Channel of Isolation Logic Tripped.Caused by Degradation of Darlington Output Transistor.Isolation Reset + (ML20012C707)
- ML20012C708 + (ML20012C708)
- ML20012C709 + (ML20012C709)
- ML20012C710 + (ML20012C710)
- IR 05000344/1990002 + (ML20012C711)
- ML20012C712 + (ML20012C712)
- ML20012C713 + (ML20012C713)