I, a as:g%

n 7

UNITED STATES ff)/[

8 NUCLEAR REGULATORY COMMISSION h

l ADVISORY COMMITTEE ON REACTOR SAFEGUARDS wAsHWGTON, D. C. 20656 hss+

March 13, 1990 i

~l i

-The Honorable Kenneth M. Carr Chairman r

U.S. Nuclear Regulatory Commission i

Washington, D.C.

20555 i

Dear' Chairman Carr:

SUBJECT:

-CONTAINMENT PERFORMANCE IMPROVEMENT PROGRAM - PROPOSED p

RECOMMENDATIONS FOR MARK II, MARK III, ICE CONDENSER, AND DRY CONTAINMENTS During the 359th mesting of the Advisory Committee on Reactor i

Safeguards, March 8-10, 1990, we discussed the staff's proposed L

recommendations from the Containment Performance Improvement-(CPI) program for' plants with Mark II, Mark III, ice condenser, and dry containments.

Tae staff intends to inform licensees with such plants of-these racommendations in a supplement to Generic Letter 88-20 (Reference 1) and, by this action, will consider the CPI program completed.

Our containment Systems Subcommittee discussed this matter with.the staff during a meeting on February 6, 1990.

We also had the benefit of the documents referenced.

The CPI program is one element described in SECY-88-147, "Inte-p grated Plan for Closure of Severe Accident Issues."

Other I

elements-in thisLplan are the Individual Plant Examination (IPE) program (Generic Letter 88-20), severe accident' research, external event: resolution, accident management, and improved plant opera-i-

tion... The CPI program was to identify any severe uccident l

vulnerabilities that appeared to be generic to plants with a given l

type - of containment.

It was then to develop new regulatory i

requirements ' or guidance for reducing those vulnerabilities.

Recommendations were to be derived by the staff and its contractors through study of risk analyses reported in NUREG-1150, other PRAs, l

and results from severe accident research.

The intent was-to L

' identify any new, requirements in the near term'so that licensees could-implement them along with any plant improvements identified

-in their own IPE efforts.

Mark I containments for BWRs were considered first. Staff guidance

-for Mark I plants was provided in Supplement No. 1 to Generic Letter 88-20 and in Generic Letter 89-16.

We provided comments on thelMark I CPI program in our report dated January 19, 1989 to then NRC Chairman l3ech.,h

'9003230022 900310 PDR ACRS q

p4 T-1389 PDC g

.V b.

r The Honorable Kenneth M. Carr 2

March 13, 1990 l,

The remaining four containment types have been considered as a group.

The staff reports that it has "found no improvements for these containment types that would warrant generic implementation

~for all containments of a given type." However, it has identified some ways, unique to each containment design, in which plants may

-be particularly vulnerable to severe accident threats.

While the staff has decided not to prescribe remedies for the generic problems it has identified, it.does intend to provide licensees with technical insights and information that the staff believes to be of particular import.

This will permit these lessons to be factored into IPEs and accident management programs that are being initiated by licensees. Summaries of the staff's concerns for each containment type are given in the proposed supplement to Generic I

Letter 88-20.

More technical details will be provided in a series of reports that are being prepared by contractors-to the staff and are expected to be available during June 1990.

The approach proposed by the staff is appropriate and we endorse the proposed supplement.

We agree that the CPI program can now be terminated.

As stated in our report of January 19, 1989 on the L

Mark I ' CPI program, the IPE program can be an - effective and

?

1 efficient means to identify and ameliorate risk-significant issues related to containment performance.

The IPE and accident manage-ment programs will benefit by considering conclusions from these staff studies.

However, we recommend that the staff caution the licensees not to focus exclusively on the set of issues raised by the CPI program.

For one thing,.the designs analyzed in NUREG-1150 do not'ade-quately represent the full spectrum of plants.

For another, conclusions about risk and phenomena are subject to large uncer-tainties..~ Licensees should retain-a broad perspective in their studies.

The original ~ intent of the IPE program, that is, to search "for' possible... ' outliers' that might be missed absent a systematic search," is applicable to issues of both prevention and mitigation.

Sincerely, faW L Carlyle Michelson Chairman

i

.s,

]

The Honorable Kenneth M. Carr 3

March 13, 1990 Referencest 1.

Memorandum dated February 22, 1990 from Warren Minners, Director, Division of Safety Issue Resolution, RES, to Raymond F. Fraley, ACRS,

Subject:

ACRS Review of Supplement 2 (sic) to Generic Letter 88-20, Individual Plant Examinations, with j

enclosures:

(a)

Proposed Draft Supplement to Generic Letter 88-20,

" completion of Containment Performance Improvement Program and Forwarding of Insights for Use in the Individual Plant Examination for Severe Accident Vulnerabilities" (Predecisional) 1 (b)

Draft menerandum for the Commissioners from James M.

Taylor, Executive Director for Operations,

Subject:

Recommendations of containment Performance Improvement Program for Plants with Mark II, Mark III, Ice Condenser, and Dry Containments (Predecisional) 2.

Letter dated November 23, 1988 from D.

Crutchfield, USNRC Office of Nuclear Reactor Regulation, to Licensees,

Subject:

Individual Plant Examination for Sevore Accident Vulner-abilities - 10 CFR S 50.54(f) (Generic Letter 88-20) 3.

Letter dated September 1, 1989 from James G.

Partlow, USNRC Office of Nuclear Reactor Regulation, to Licensees,

Subject:

Installation of a Hardened Wetwell Vent (Generic Letter 89-i 16) 4.

Letter dated August 29, 1989 from James G.

Partlow, USNRC Office of Nuclear Reactor Regulation, to Licensees,

Subject:

Initiation of the Individual Plant Examination for Severe Accident Vulnerabilities - 10 CFR $ 50.54(f) - Generic Letter 88-20, Supplement No. 1 1

5.

U.S.

Nuclear Regulatory Commission, NUREG-1150,

" Severe Accident Risks:

An Assessment for Five U.S.

Nuclear Power Plants (Second Draft for Peer Review)," Volumes 1 and 2, June 1989 6.

SECY-88-147, Memorandum dated May 28, 1988 for the Commis-sioners from Victor Stello, Executive Director for Operations,

Subject:

Integration Plan for closure of Severe Accident Issues

-