- ML17328A105 + (ML17328A105)
- ML17328A106 + (ML17328A106)
- ML17328A107 + (ML17328A107)
- ML17328A108 + (ML17328A108)
- ML17328A109 + (ML17328A109)
- ML17328A110 + (ML17328A110)
- ML17328A111 + (ML17328A111)
- ML17328A112 + (ML17328A112)
- ML17328A113 + (ML17328A113)
- ML17328A114 + (ML17328A114)
- ML17328A116 + (ML17328A116)
- ML17328A118 + (ML17328A118)
- ML17328A119 + (ML17328A119)
- ML17328A120 + (ML17328A120)
- ML17328A121 + (ML17328A121)
- ML17328A122 + (ML17328A122)
- ML17328A124 + (ML17328A124)
- ML17328A125 + (ML17328A125)
- 05000315/LER-1989-004, :on 890324,leakage Found on Containment Penetrations Exceeded Tech Spec 3.6.1.2.b Requirement.Caused by Excessive Leakage Rate of Valves WCR-924,ECR-26 & ECR-31. Faulty Valves Repaired & Restested + (ML17328A126)
- ML17328A127 + (ML17328A127)
- ML17328A129 + (ML17328A129)
- ML17328A130 + (ML17328A130)
- ML17328A132 + (ML17328A132)
- IR 05000315/1989022 + (ML17328A133)
- ML17328A135 + (ML17328A135)
- ML17328A136 + (ML17328A136)
- ML17328A137 + (ML17328A137)
- ML17328A139 + (ML17328A139)
- ML17328A143 + (ML17328A143)
- ML17328A146 + (ML17328A146)
- ML17328A149 + (ML17328A149)
- ML17328A150 + (ML17328A150)
- ML17328A151 + (ML17328A151)
- ML17328A152 + (ML17328A152)
- ML17328A153 + (ML17328A153)
- 05000315/LER-1989-009, :on 890705,disovered That Testing Document for Valve 1-CS-443-2 Not Signed Off.Record Search Conducted & No Evidence Found to Indicate That post-maint Testing Performed.Caused by Personnel Error + (ML17328A154)
- 05000316/LER-1989-014, :on 890814,reactor Protection Sys Actuation Occurred Due to Failure of Class 1E Power Supply Inverter. Caused by Failed Silicon Controlled Rectifier in Static Transfer Switch.Inverter Repaired + (ML17328A155)
- ML17328A156 + (ML17328A156)
- ML17328A159 + (ML17328A159)
- ML17328A161 + (ML17328A161)
- IR 05000315/1989023 + (ML17328A162)
- ML17328A163 + (ML17328A163)
- ML17328A164 + (ML17328A164)
- 05000316/LER-1989-015, :on 890821,inoperable Open Fire Damper Subj to Constraints of Tech Spec 3.7.10 Found Which Action Statement Requirements Not Implemented.Caused by Misconception by Person Developing Task Sheet for Maint Insps + (ML17328A165)
- ML17328A166 + (ML17328A166)
- IR 05000315/1989025 + (ML17328A168)
- ML17328A169 + (ML17328A169)
- ML17328A174 + (ML17328A174)
- ML17328A175 + (ML17328A175)
- ML17328A176 + (ML17328A176)
- ML17328A177 + (ML17328A177)