 Issue dateTitleTopic
ML20217K91515 October 1999SER Authorizing Util Relief Request RR-ENG-2-3 for Second 10-year ISI Interval of Stp,Units 1 & 2 Pursuant to 10CFR50.55a(a)(3)(i)Nondestructive Examination
Incorporated by reference
ML20217K94415 October 1999SER Accepting Util Alternative Proposed Relief Request RR-ENG-2-4 for Second 10-year ISI Interval at Stp,Units 1 & 2 Pursuant to 10CFR50.55a(a)(3)(i)Nondestructive Examination
ML20217D05330 September 1999Rev 1 to STP Electric Generating Station Unit 2 Cycle 7 Colr
NOC-AE-000676, Monthly Operating Repts for Sept 1999 for South Texas Project,Units 1 & 2.With30 September 1999Monthly Operating Repts for Sept 1999 for South Texas Project,Units 1 & 2.With
ML20217D04830 September 1999Rev 1 to STP Electric Generating Station Unit 1 Cycle 9 Colr
ML17300B38130 September 1999Monthly Operating Repts for Sept 1999 for Pvngs,Units 1,2 & 3.With 991007 Ltr
ML20211P7819 September 1999SER Approving Second 10-year Interval Inservice Insp Program Plan Relief Request RR-ENG-2-8 (to Use Code Case N-491-2) for South Texas Project,Units 1 & 2Incorporated by reference
ML20211P8419 September 1999Safety Evaluation Supporting Alternative Proposed by Licensee to Surface Exam to Perform Boroscopic VT-1 Visual Exam of Pump Casing Welds within Pump Pits for Welds Covered by Relief Request RR-ENG-24Incorporated by reference
ML20211Q6739 September 1999Safety Evaluation Accepting First 10-yr Interval ISI Program Plan Request for Relief from ASME Code Case N-498Boric Acid
Hydrostatic
VT-2
Incorporated by reference
NOC-AE-000643, Monthly Operating Repts for Aug 1999 for South Texas Project,Units 1 & 2.With31 August 1999Monthly Operating Repts for Aug 1999 for South Texas Project,Units 1 & 2.With
ML20212E51931 August 1999Rev 3 to SG-99-04-005, STP 1RE08 Outage Condition Monitoring Rept & Final Operational Assessment
ML17300B32731 August 1999Monthly Operating Rept for Aug 1999 for Pvngs,Units 1,2 & 3
ML17313B07527 August 1999LER 99-002-00:on 990730,test Mode Trip Bypass for EDG Output Breakers Not Surveilled.Cause Under Investigation.Operations Personnel Conservatively Invoked SR 3.0.3 for SR 3.8.1.13. with 990827 LtrMissed surveillance
ML20211F45324 August 1999Safety Evaluation Supporting Licensee Proposed Alternative to Defer Partial First Period Exams of flange-to-shell Weld to Third Period & Perform Required Ultrasonic Exams,Both Manual & Automated,During Third PeriodNon-Destructive Examination
Incorporated by reference
ML20211F51123 August 1999Safety Evaluation Supporting Licensee Proposed Alternative Contained in Request for Relief RR-ENG-30Nondestructive Examination
VT-2
Incorporated by reference
ML20210C94131 July 1999Rev 1 to SG-99-07-002, South Tx,Unit 1 Cycle 9 Voltage- Based Repair Criteria 90-Day Rept, Jul 1999
ML20210R36331 July 1999Monthly Operating Repts for July 1999 for South Tx Project, Units 1 & 2.With
ML17313B06131 July 1999Monthly Operating Repts for July 1999 for Pvngs,Units 1,2 & 3.With 990810 Ltr
ML20210D91623 July 1999Safety Evaluation Accepting Inservice Testing Relief Request RR-56 Re Component Cooling Water & Safety Injection Sys Containment Isolation Check Valve Closure Test FrequencyEnforcement Discretion
Probabilistic Risk Assessment
Incorporated by reference
Foreign Material Exclusion
Large early release frequency
ML20210D44921 July 1999Revised Chapters to Operations QA Plan, Including Rev 9 to Chapter 1.0, Organization & Rev 6 to Chapter 16.0, Independent Technical Review
ML20210D48221 July 19991RE08 ISI Summary Rept for Steam Generator Tubing of South Texas Project Electric Generating Station Unit 1
ML17313B01916 July 1999LER 99-005-00:on 990618,RT on Low DNBR Was Noted.Caused by Hardware Induced Calculation Error.Cr Operator Was Taken to Place Reactor in Stable Condition IAW Appropriate Operating ProcedureAnticipated operational occurrence
NOC-AE-000583, LER 99-S03-00:on 990619,failure to Revitalize Sdg Number 11 Was Noted.Caused by Failure to Communicate Status of Sdg. Subject Sdg Revitalized on 990619 & Licensee Will Develop Security Force Instruction Re Sdgs.With15 July 1999LER 99-S03-00:on 990619,failure to Revitalize Sdg Number 11 Was Noted.Caused by Failure to Communicate Status of Sdg. Subject Sdg Revitalized on 990619 & Licensee Will Develop Security Force Instruction Re Sdgs.With
ML20207H6368 July 1999Safety Evaluation Approving 2nd 10 Yr Interval ISI Program Plan Request to Use ASME Section XI Code Case N-546 for Licenses NPF-76 & NPF-80,respectivelyNondestructive Examination
VT-2
Incorporated by reference
ML20216D7487 July 19991RE08 ISI Summary Rept for Welds & Component Supports of STP Electric Generating Station,Unit 1Nondestructive Examination
VT-2
Liquid penetrant
ML17300B31530 June 1999Monthly Operating Repts for June 1999 for Pvngs,Units 1,2 & 3.With 990714 Ltr
NOC-AE-000593, Monthly Operating Repts for June 1999 for Stp,Units 1 & 2. with30 June 1999Monthly Operating Repts for June 1999 for Stp,Units 1 & 2. with
NOC-AE-000570, LER 99-S01-00:on 990527,discovered That Unescorted Access Had Been Inappropriately Granted.Caused by Failure to Follow Procedure.Util Verified That Individual Did Not Have Current Unescorted Access at STP or Any Other Util.With28 June 1999LER 99-S01-00:on 990527,discovered That Unescorted Access Had Been Inappropriately Granted.Caused by Failure to Follow Procedure.Util Verified That Individual Did Not Have Current Unescorted Access at STP or Any Other Util.With
ML20196G58223 June 1999LER 99-S02-00:on 990601,failure to Maintain Positive Control of Vital Area Security Key Was Noted.Caused by Lack of Attention to Detail.Discussed Event with Operator Involved IAW Constructive Discipline ProgramStolen
ML17313A99221 June 1999Special Rept:On 990525,RMS mini-computer Was Removed from Service to Implement Yr 2000 Mod & Was OOS Longer than 72 H Allowed.Caused by Planned Y2K Mods.Preplanned Alternate Sampling Program Was InitiatedOffsite Dose Calculation Manual
ML17313A99118 June 1999Special Rept:On 990510,loose-part Detection Sys Channel 2 Was Declared Inoperable.Caused by Malfunction of Mineral Cable Connector to Accelerometer.Licensee Will Implement Modifications Which Will Enhance loose-part Detection Sys
ML20195J68717 June 1999Safety Evaluation Supporting Proposed Alternative Contained in RR-ENG-2-5.Proposed Alternative Authorized Per 10CFR50.55a(a)(3)(i) for 2nd ISI IntervalIncorporated by reference
ML20196A23915 June 1999Change QA-042 to Rev 13 of Operations QAP, Reflecting Current Organizational Alignment for South Texas Project & Culminating Organizational Realigment That Has Been Taking Place During Past Several MonthsNondestructive Examination
Fire Protection Program
ML17313A97331 May 1999Monthly Operating Repts for May 1999 for Pvngs,Units 1,2 & 3.With 990608 Ltr
NOC-AE-000563, Monthly Operating Repts for May 1999 for Stp,Units 1 & 2. with31 May 1999Monthly Operating Repts for May 1999 for Stp,Units 1 & 2. with
ML20206U54118 May 1999Non-proprietary Errata Pages for Rev 2,Addendum 1 to WCAP-13699, Laser Welded Sleeves for 3/4 Inch Diamete Tube Feedring Type & W Preheater SGs Generic Sleeving Rept
ML17313A9287 May 1999LER 99-004-00:on 990408,PSV Lift Pressures Were Outside of TS Limits.Caused by Lift Pressure Setpoint Drift.Psvs Have Been Tested,Disassembled,Inspected,Reassembled & Certified at Wyle Labs
ML17313A92030 April 1999Monthly Operating Repts for Apr 1999 for Pvngs,Units 1,2 & 3.With 990512 Ltr
ML20206A77230 April 1999STP Electric Generating Station Unit 1 Cycle 9 Colr
NOC-AE-000543, Monthly Operating Repts for Apr 1999 for Stp,Units 1 & 2. with30 April 1999Monthly Operating Repts for Apr 1999 for Stp,Units 1 & 2. with
ML17313A89514 April 1999LER 99-003-00:on 990317,required Surveillance Requirement Not Completed Due to Deficient Procedure,Was Determined. Caused by Cognitive Personnel Error.St Procedures Revised to Require Chiller to Be Operating & Oil Temperature CheckedUltimate heat sink
Missed surveillance
ML17313A89213 April 1999LER 98-003-01:on 980902,discovered That MSSV as-found Lift Pressures Were Outside TS Limits.Caused by Bonding of Valve Disc to Nozzle Seat.Affected Valves Were Adjusted,Retested & Returned to Svc
ML17313A8899 April 1999LER 99-001-00:on 990310,RT on High Pressurizer Pressure Was Noted.Caused by Loss of Heat Removal.Cr Supervisor Was Removed from Shift Duties for Diagnostics Skills Training. with 990409 LtrShutdown Margin
ML17313A88031 March 1999Monthly Operating Repts for Mar 1999 for Pvngs,Units 1,2 & 3.With 990412 Ltr
ML20205H03231 March 1999Change QA-040 to Rev 13 of Operations QA PlanNondestructive Examination
ML17300B30731 March 1999Seismic Portion of Submittal-Only Screening Review of Palo Verde Nuclear Generating Station Units Ipeee.Safe Shutdown
Safe Shutdown Earthquake
Design basis earthquake
Earthquake
NOC-AE-000507, Monthly Operating Repts for Mar 1999 for Stp,Units 1 & 2. with31 March 1999Monthly Operating Repts for Mar 1999 for Stp,Units 1 & 2. with
ML20205A37822 March 1999STP Electric Generating Station Simulator Certification Four Yr Rept for Units 1 & 2
ML20204B27115 March 1999Safety Evaluation Authorizing 990201 Request to Authorize Alternative to Regulations Per 10CFR50.55a(a)(3)(i) That Would Revise Start of Second 120-month IST Interval to No Later than 011201Incorporated by reference
ML20207M92312 March 1999Amended Part 21 Rept Re Cooper-Bessemer Ksv EDG Power Piston Failure.Total of 198 or More Pistons Have Been Measured at Seven Different Sites.All Potentially Defective Pistons Have Been Removed from Svc Based on Encl Results