 Issue dateTitleTopic
ML20217N43825 October 1999Safety Evaluation Supporting Amend 17 to License DPR-9
ML20217P35522 October 1999LER 99-S01-00:on 990922,loaded 9mm Handgun Was Discovered on Truck Cargo Area of Vehicle Inside Protected Area.Caused by Inadequate Vehicle Search.Guidance in Procedures & Security Training to Address Multiple Vehicle Searches Was ProvidedContraband
Stolen
ML20217G21615 October 1999Errata Pages 2 & 3 for Safety Evaluation Supporting Amend 168 Issued to FOL DPR-63 Issued on 990921.New Pages Change Description of Flow Control Trip Ref Cards to Be Consistent with Application for AmendFuel cladding
ML20217D30613 October 1999SER Accepting Licensee Proposed Changes to Edwin I Hatch Nuclear Plant Emergency Classification Scheme to Add Emergency Action Levels Related to Operation of Independent Spent Fuel Storage InstallationEarthquake
ML20217C91212 October 1999SER Input Authorizing Licensee Proposed Request to Modify Definition of Core Alteration in Section 1.0 of TS & Update Sections 3/4.1,3.4.3 & 3/4.9 to Reflect Proposed Definition ChangeShutdown Margin
Spiral reload
ML20217F90930 September 1999Monthly Operating Repts for Sept 1999 for LaSalle County Stations,Units 1 & 2.WithCoast down
ML20216J92530 September 1999Suppl to Special Rept:On 990621,11 Containment Hydrogen Monitoring Sys Chart Recorder Was Indicating Below Normal Operating Range.Caused by Excessive Wear on Valve Body & Discs of Bypass Pump.Sample Pump Replaced
ML20217D12630 September 1999Monthly Operating Rept for Sept 1999 for Monticello Nuclear Generating Plant.With
ML20217K46330 September 1999Monthly Operating Rept for Sept 1999 for Nine Mile Point, Unit 1.With
HL-5845, Monthly Operating Repts for Sept 1999 for Ei Hatch Nuclear Plant.With30 September 1999Monthly Operating Repts for Sept 1999 for Ei Hatch Nuclear Plant.With
ML17300B38130 September 1999Monthly Operating Repts for Sept 1999 for Pvngs,Units 1,2 & 3.With 991007 Ltr
NRC-99-0095, Monthly Operating Rept for Sept 1999 for Fermi 2.With30 September 1999Monthly Operating Rept for Sept 1999 for Fermi 2.With
U-603277, Monthly Operating Rept for Sept 1999 for Clinton Power Station,Unit 1.With30 September 1999Monthly Operating Rept for Sept 1999 for Clinton Power Station,Unit 1.With
ML20217H52230 September 1999Monthly Operating Repts for Sept 1999 for Byron Station, Units 1 & 2.With
ML20217D12130 September 1999Monthly Operating Repts for Sept 1999 for Lgs,Units 1 & 2. with
ML20217P63529 September 1999Non-proprietary Rev 6 to HI-982083, Licensing Rept for Spent Fuel Rack Installation at Byron & Braidwood Nuclear StationsSafe Shutdown Earthquake
Operating Basis Earthquake
Earthquake
ML20217A16922 September 1999Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers
ML20212F73021 September 1999Special Rept:On 990907,CR Operators Declared 12 Containment Hydrogen Monitoring Sys Inoperable for Planned Maint.Cause of Low Flow Condition Was Determined to Be Foreign Matl. Replaced Sample Pump Valve Discs
ML20212B90814 September 1999Special Rept:On 990901, 12 Containment Hydrogen Monitoring Sys Was Declared Inoperable for Planned Maint.Caused by Planned Maint Being Performed as Corrective Action.Check Valves with O Rings Were Replaced
ML20212A66413 September 1999Safety Evaluation Authorizing Relief Request RR-V-16 for Third 10 Yr Interval Inservice Testing Program
ML20212A88613 September 1999Safety Evaluation Authorizing First & Second 10 Yr Interval Inservice Insp Plan Requestss for Relief RR-01Hydrostatic
Nondestructive Examination
VT-2
Incorporated by reference
Liquid penetrant
Pressure boundary leak
ML20212B92631 August 1999Monthly Operating Repts for Aug 1999 for Byron Station,Units 1 & 2.With
ML20212A44831 August 1999Monthly Operating Repts for Aug 1999 for Limerick Generating Station,Units 1 & 2.With
U-603267, Monthly Operating Rept for Aug 1999 for Clinton Power Station,Unit 1.With31 August 1999Monthly Operating Rept for Aug 1999 for Clinton Power Station,Unit 1.With
ML20216F51431 August 1999Rept on Status of Public Petitions Under 10CFR2.206Unanalyzed Condition
Hydrostatic
ML20216E70331 August 1999Monthly Operating Rept for Aug 1999 for Monticello Nuclear Generating Plant.With
HL-5836, Monthly Operating Repts for Aug 1999 for Edwin I Hatch Nuclear Plant.With31 August 1999Monthly Operating Repts for Aug 1999 for Edwin I Hatch Nuclear Plant.With
ML20212C46031 August 1999Monthly Operating Rept for Aug 1999 for Nine Mile Point Nuclear Station,Unit 1.With
ML20212C45031 August 1999Monthly Operating Repts for Aug 1999 for LaSalle County Station,Units 1 & 2.WithCoast down
NRC-99-0067, Monthly Operating Rept for Aug 1999 for Fermi 2.With31 August 1999Monthly Operating Rept for Aug 1999 for Fermi 2.With
ML17300B32731 August 1999Monthly Operating Rept for Aug 1999 for Pvngs,Units 1,2 & 3
ML17313B07527 August 1999LER 99-002-00:on 990730,test Mode Trip Bypass for EDG Output Breakers Not Surveilled.Cause Under Investigation.Operations Personnel Conservatively Invoked SR 3.0.3 for SR 3.8.1.13. with 990827 LtrMissed surveillance
ML20211E98920 August 1999LGS Unit 2 Summary Rept for 970228 to 990525 Periodic ISI Rept Number 5Hydrostatic
VT-2
EVT-1
ML20210Q0524 August 1999Safety Evaluation Approving Relief Request 10 to License DPR-22 Per 10CFR50.55a(g)(6)(i).Inservice Exam for Relief Request 10,Parts A,B,C,D & E Impractical & Reasonable Assurance of Structural Integrity ProvidedBoric Acid
Hydrostatic
Incorporated by reference
ML20210J9272 August 1999SER Finds That Licensee Performed Appropriate Evaluations of Operational Configurations of safety-related power-operated Gate Valves to Identify Valves at Plant,Susceptible to Pressure Locking or Thermal BindingBackfit
ML20210J9632 August 1999SER Finding That Licensee Established Acceptable Program to Verify Periodically design-basis Capability of safety-related MOVs at Edwin I Hatch Nuclear Plant,Units 1 & 2Stroke time
ML20210Q66131 July 1999Monthly Operating Rept for July 1999 for Monticello Nuclear Generating Plant.With
HL-5818, Monthly Operating Repts for July 1999 for Ei Hatch Nuclear Plant,Units 1 & 2.With31 July 1999Monthly Operating Repts for July 1999 for Ei Hatch Nuclear Plant,Units 1 & 2.With
ML20210R34331 July 1999Monthly Operating Repts for July 1999 for Byron Station, Units 1 & 2.With
ML20210L70531 July 1999Monthly Operating Repts for July 1999 for Limerick Generating Station,Units 1 & 2.With
U-603245, Monthly Operating Rept for Jul 1999 for CPS Unit 1.With31 July 1999Monthly Operating Rept for Jul 1999 for CPS Unit 1.With
ML20210U45931 July 1999Monthly Operating Rept for July 1999 for Nine Mile Point, Unit 1.With
NRC-99-0065, Monthly Operating Rept for July 1999 for Fermi 2.With31 July 1999Monthly Operating Rept for July 1999 for Fermi 2.With
ML17313B06131 July 1999Monthly Operating Repts for July 1999 for Pvngs,Units 1,2 & 3.With 990810 Ltr
ML20210R06731 July 1999Monthly Operating Repts for July 1999 for LaSalle County Station,Units 1 & 2.WithZebra Mussel
Downpower
ML20211C96226 July 1999ISI Summary ReptHydrostatic
Anchor Darling
Nondestructive Examination
VT-2
Liquid penetrant
ML20210E22521 July 1999B1R09 ISI Summary Rept Spring 1999 Outage, 980309-990424Boric Acid
Hydrostatic
Nondestructive Examination
VT-2
Pressure Boundary Leakage
ML17313B01916 July 1999LER 99-005-00:on 990618,RT on Low DNBR Was Noted.Caused by Hardware Induced Calculation Error.Cr Operator Was Taken to Place Reactor in Stable Condition IAW Appropriate Operating ProcedureAnticipated operational occurrence
ML20210C1689 July 1999Seventh Refueling Outage ASME Section XI Summary ReptPacking leak
Hydrostatic
VT-2
U-603232, Special Rept:On 990531 Lpms Was Declared Inoperable Due to Receipt of High Vibration & Loose Parts Alarm Which Did Not Clear.Lpms Was Restored to Operable Status on 990707 After Alignment & Tension on Recorder Tape Drive Was Adjusted9 July 1999Special Rept:On 990531 Lpms Was Declared Inoperable Due to Receipt of High Vibration & Loose Parts Alarm Which Did Not Clear.Lpms Was Restored to Operable Status on 990707 After Alignment & Tension on Recorder Tape Drive Was Adjusted