ML20209J196 | 12 July 1999 | Special Rept 99-001:on 990528,smoke Detectors Failed to Alarm During Performance of Routine Channel Functional Testing.Applicable TRM Interim Compensatory Measure of Establishing Roving Hourly Fire Patrol Was Implemented | |
ML20203B558 | 4 December 1997 | Special Rept 97-003:on 971111,valid Failure of Div 2 EDG Occurred,Due to Jacket Water Leak.Failure Reported,Per Plant Technical Requirements Manual Section 7.7.2.2 | |
ML20211P231 | 16 October 1997 | Special Rept 97-02:on 970916,during Routine Monthly Surveillance Run,Jacket Water Leak Developed at Dresser Coupling Joint.Jacket Water Leak Repaired & EDG Sucessfully Retested & Returned to Operable Status | |
ML20217Q696 | 26 August 1997 | Special Rept 97-001:on 970730,valid Failure of Div 1 EDG Occurred Due to Jacket Water Leak.Faulty Lube Oil Temp Switch Was Replaced & Jacket Water Leak Was Repaired | |
ML20134N060 | 15 November 1996 | Special Rept 96-003:on 961016,smoke Detector in Zone 1-3 of Hot Machine Shop/Turbine Bldg Covered to Allow for Welding & Grinding in Area.Hourly Firewatch Established to Patrol & Inspect Affected Portion of Zone | |
ML20134L906 | 11 November 1996 | Special Rept 96-002:on 961010,valid Failure of Div 2 EDG Occurred.Caused by Loose Barring Device Pivot Bolt.Bolt Tightened & Staked & Root Cause Evaluation Is Being Conducted | |
ML20101N068 | 1 April 1996 | Special rept:96/001 on 960229,EDG Failed.Cause by Failed Shuttle Valve.C/A:Valve Replaced | |
ML20095K396 | 21 December 1995 | Special Rept:On 951127,valid Failure of Div 1 EDG Occurred. Exact Sequence of Events Could Not Be Determined.Insps Done W/No Abnormalities Discovered | |
ML20095H252 | 15 December 1995 | Special Rept:On 951117,invalid Failure of Div 13 HPCS EDG Occurred.Caused by Faulty Sync Check Relay in Paralleling Circuit.Sync Check Relay Repaired | |
ML20087F933 | 11 August 1995 | Special Rept 95-003:on 950728,acccident Range Monitor Exceeds TRM Allowed Down Time.Interface Box Replaced,Calibr Restarted & Tested Satisfactory | |
ML20086E139 | 30 June 1995 | RO 95-002:on 950605,invalid Failure of Division 13,HPCS EDG Occurred.Surveillance Procedures Used for ECCS Testing Will Be Evaluated to Provide Alternate Method for Initiating Trip Signals,Thereby Eliminating Need for Finger Relays | |
ML20081K170 | 23 March 1995 | Special Rept:On 950307,wind Speed & Direction for Channels a & B Disabled.Caused by Lightning Striking Meteorological Monitoring Tower.Lco 95-0254 Written to Document Event | |
ML20078S346 | 14 December 1994 | Special Rept:On 941117,EDG 12 Was Started for Maint Run Following Maint Outage & Run Was Successfully Completed | Coast down |
ML20065S300 | 11 May 1994 | Special Rept 94-004:on 940411,during Monthly Functional Test,Invalid Failure of EDG 13 Occurred Due to Personnel Error.Troubleshooting Run Performed & EDG Subsequently Tested Satisfactorily | |
ML20065L044 | 13 April 1994 | Special Rept 94-003:on 940327,lightning Strike Occurred on Meteorological Monitoring Tower,Rendering Meteorological Monitoring Instrumentation Channels Inoperable for More than Seven Days.Available Sensors Replaced as of 940412 | |
ML20064J051 | 14 March 1994 | Special Rept on 940228,wind Direction Indicator Located at Meterological Facility Did Not Change in Response to Wind Changes.Wind Direction Sensor Replaced & Readings Verified W/B Indicator | |
ML20063H673 | 14 February 1994 | Special Rept 94-001:on 940113,Div 2 Sdg 12 Experienced Invalid Failure During Surveillance Due to False High Jacket Water Temp Signal Generated by Faulty Jacket Water Temp Switch.Switch Replaced & Tested | |
ML20058D248 | 23 November 1993 | Special Rept 93-005:on 931019,during Insp of Low Pressure Turbine Rotor C,Several Recordable Indications Identified. Caused by Stress Corrosion Cracking.Existing Condition Acceptable W/O Restriction for Continued Operations | |
ML20058C939 | 16 November 1993 | Special Rept 93-006:on 931109,area Radiation Monitors Were Inoperable Due to Performance of Plant Surveillance Containment/Drywell High Range Area Radiation Monitor Calibr.Arm Returned to Operable Status | |
ML20059G758 | 2 November 1993 | Special Rept:On 930926,TS Violation Occurred Due to SSW Pump House Strong Motion Accelerometer Recorder Calibration Failure.Ordered New Replacement Parts | |
ML20057B262 | 13 September 1993 | Special Rept 93-003:on 930812,invalid Failure of EDG 12 Occurred Due to Leaking Jacket Water Coupling.Coupling Gaskets Replaced & Coupling Satisfactorily Checked for Leaks | |
ML20116L685 | 13 November 1992 | Special Rept 92-008:on 921014,emergency Diesel Generator 11 Failed Due to Water in Cylinder.Caused by Crack in Cylinder Head.Head Replaced & EDG 11 Retested | Nondestructive Examination |
ML20116K784 | 11 November 1992 | Special Rept 92-007:on 921013,EDG 11 Started But Start Signal Indicating Light Did Not Illuminate & Local Operator Unable to Verify EDG Acceleration.Possibly Caused by Blown Bulb.Edg 11 Functional Test Successfully Performed | |
ML20115E193 | 15 October 1992 | Special Rept 92-006:on 920915,EDG 11 Tripped While Preparing to Perform Function Test of EDG 11 Per Surveillance Procedure 06-OP-1P75-M-0001.Caused by Leaking Reset Air Tubing Connection.Technicians Trained | |
ML20105C859 | 15 September 1992 | Special Rept 92-005:on 920818,emergency Diesel Generator 11 Tripped Due to High Vibration Signal During Maint Run. Instructions Will Be Issued to Perform Simulated Diesel Run as post-maint Partial Check of Pneumatic Computer | |
ML20099A986 | 23 July 1992 | Special Rept 92-004:on 920623,SDG 11 Tripped Due to High Vibration Signal.Caused by Loose Screw Due to Inadequate Procedure.Maint Procedure Governing Calibr of Vibration Sensors Will Be Revised | |
ML20101H725 | 26 June 1992 | Special Rept 92-003-00:on 920525,Div 1 Standby DG 11 Experienced Nonvalid Failure.Caused by Excessive Contact Resistance.Comprehensive Loading Increased on One of Six Sets of Contacts in Svc & Selector Switch Bypassed | |
ML20098D164 | 15 May 1992 | Special Rept 92-002:on 920505,containment & Drywell Accident Range Area Radiation Monitors Removed from Svc for More than 72 H.Preplanned Alternate Method of Monitoring Area Radiation Monitors Established to Work Area | |
ML20090A391 | 27 February 1992 | Special Rept 92-001:on 920128,diesel Generator 11 Output Breaker Would Not Close During Monthly Functional Surveillance,Preventing Generator from Being Loaded to Grid. Power Converter Assembly for Tachometer Replaced | |
ML20082B667 | 9 July 1991 | Special Rept 91-005:on 910618,invalid Failure of Emergency Diesel Generator 11 Occurred.Caused by Loose Terminal Connection in Paralleling Circuitry at Generator Breaker. Connection Tightened & Generator Tested Sastisfactorily | |
ML20079C330 | 12 June 1991 | Special Rept:On 910513,emergency Diesel Generator II Failed During Monthly Standby Diesel Generator Functional Test. While Reaching Max Load,Oscillations Observed in Dc Field Volt,Dc Field Amps & Ac Amps | |
ML20072U561 | 12 April 1991 | Special Rept 89-001-01:on 890201,output Breaker for DG 12 Failed to Close While Attempting to Parallel Generator W/ Energized Bus.Caused by Malfunction of Tachometer Transmitter.Upgraded Transmitters Installed | |
ML20070D346 | 25 February 1991 | Special Rept 91-003:on 910127,smoke Detectors Found Covered W/Plastic Bags in Panel 1H13P733,rendering Detectors Inoperable.Plastic Bags Removed & Surveillance Resumed | Fire Watch |
ML20065U432 | 27 December 1990 | Special Rept 90-003-00:on 901127,diesel Generator Declared Inoperable During Performance of Monthly Functional Surveillance in Accordance W/Tech Spec 4.8.1.1.2.Monitoring of Diesel Generator Performed to Provide Corrective Actions | |
AECM-90-0138, Special Rept:On 900627,fire Detection Instrumentation Declared Inoperable & Firewatch Established as Required by Tech Spec 3.3.7.9.Detectors Restored to Svc | 31 July 1990 | Special Rept:On 900627,fire Detection Instrumentation Declared Inoperable & Firewatch Established as Required by Tech Spec 3.3.7.9.Detectors Restored to Svc | |
AECM-89-0168, Special Rept 89-007/0:on 890804,diesel Generator 13 Failed to Properly Load During Monthly Functional Surveillance. Caused by Failure of Motor Operator Potentiometer in Governor Control Circuit.Potentiometer Replaced | 31 August 1989 | Special Rept 89-007/0:on 890804,diesel Generator 13 Failed to Properly Load During Monthly Functional Surveillance. Caused by Failure of Motor Operator Potentiometer in Governor Control Circuit.Potentiometer Replaced | |
AECM-89-0127, Special Rept 89-006/0:on 890603,smoke Detector NSP65N627H in Fire Zone 2-04 of Auxiliary Bldg Continuously Alarmed & Failed to Reset.Caused by Steam Leakage in RWCU Sys Recirculation Pump B Room.Leakage Repaired | 29 June 1989 | Special Rept 89-006/0:on 890603,smoke Detector NSP65N627H in Fire Zone 2-04 of Auxiliary Bldg Continuously Alarmed & Failed to Reset.Caused by Steam Leakage in RWCU Sys Recirculation Pump B Room.Leakage Repaired | |
AECM-89-0118, Special Rept 89-005/0:on 890606,meteorological Monitoring Instrumentation Channels a & B Removed from Svc for Planned Maint Due to Environ Degrading of Equipment.Terminal Boxes & Cabling Replaced & Instrumentation Returned to Svc | 21 June 1989 | Special Rept 89-005/0:on 890606,meteorological Monitoring Instrumentation Channels a & B Removed from Svc for Planned Maint Due to Environ Degrading of Equipment.Terminal Boxes & Cabling Replaced & Instrumentation Returned to Svc | |
AECM-89-0104, Special Rept 88-007/1:on 881214,field Amps,Line Amps & Generator MVARs Began Oscillating During Diesel Generator 11 Surveillance.Caused by Number 1 Rectifier Bridge Circuit. Diesel Generator Restarted,Loaded & Surveillance Completed | 31 May 1989 | Special Rept 88-007/1:on 881214,field Amps,Line Amps & Generator MVARs Began Oscillating During Diesel Generator 11 Surveillance.Caused by Number 1 Rectifier Bridge Circuit. Diesel Generator Restarted,Loaded & Surveillance Completed | |
AECM-89-104, Special Rept 88-007/1:on 881214,field Amps,Line Amps & Generator MVARs Began Oscillating During Diesel Generator 11 Surveillance.Caused by Number 1 Rectifier Bridge Circuit. Diesel Generator Restarted,Loaded & Surveillance Completed | 31 May 1989 | Special Rept 88-007/1:on 881214,field Amps,Line Amps & Generator MVARs Began Oscillating During Diesel Generator 11 Surveillance.Caused by Number 1 Rectifier Bridge Circuit. Diesel Generator Restarted,Loaded & Surveillance Completed | |
AECM-89-0091, Special Rept 89-004/0:on 890405,smoke Detector in Fire Zone 1-03 of Control Bldg Spuriously Alarmed.Smoke Detector Alarm Declared Inoperable.Cause Not Determined.Detector Cleaned, Retested & Returned to Svc on 890428 | 5 May 1989 | Special Rept 89-004/0:on 890405,smoke Detector in Fire Zone 1-03 of Control Bldg Spuriously Alarmed.Smoke Detector Alarm Declared Inoperable.Cause Not Determined.Detector Cleaned, Retested & Returned to Svc on 890428 | Hourly Fire Watch |
AECM-89-0089, Special Rept 89-003/0:on 890404,fluctuations in Exciter Volts & Amps Observed in Diesel Generator During Monthly Surveillance.Caused by High Resistance Across Set of Normally Closed Contacts on Relay Resulting from Oxidation | 4 May 1989 | Special Rept 89-003/0:on 890404,fluctuations in Exciter Volts & Amps Observed in Diesel Generator During Monthly Surveillance.Caused by High Resistance Across Set of Normally Closed Contacts on Relay Resulting from Oxidation | |
AECM-89-0056, Special Rept 89-002:on 890225,turbine Bldg Ventilation Exhaust Accident Range Radiation Monitor Removed from Svc. Channels 3 & 4 Failed & Channel 4 Remained in Check Source. Monitor Retested Satisfactorily & Restored to Svc on 890302 | 9 March 1989 | Special Rept 89-002:on 890225,turbine Bldg Ventilation Exhaust Accident Range Radiation Monitor Removed from Svc. Channels 3 & 4 Failed & Channel 4 Remained in Check Source. Monitor Retested Satisfactorily & Restored to Svc on 890302 | |
AECM-89-0048, Special Rept:On 890201,diesel Generator Failed to Load During Test.Caused by Malfunction of Tachometer Transmitter. Transmitter Replaced & Diesel Generator Functional Test Successfully Completed | 2 March 1989 | Special Rept:On 890201,diesel Generator Failed to Load During Test.Caused by Malfunction of Tachometer Transmitter. Transmitter Replaced & Diesel Generator Functional Test Successfully Completed | |
AECM-88-0205, Followup Ro:Re Incident Involving Stuck Peripheral Orifice Fuel Assembly During Second Refueling Outage.Stuck Bundle Successfully Removed W/O Complications.No Plans Exist to Reuse Formerly Stuck Assembly | 15 November 1988 | Followup Ro:Re Incident Involving Stuck Peripheral Orifice Fuel Assembly During Second Refueling Outage.Stuck Bundle Successfully Removed W/O Complications.No Plans Exist to Reuse Formerly Stuck Assembly | Enforcement Discretion |
ML20205P344 | 4 November 1988 | Special Rept 88-004:on 881021,containment Ventilation Exhaust Accident Range Radiation Monitor Removed from Svc. Erratic Readings Observed During Surveillance.Caused by Damaged Cable Assembly.Channel 2 Tube Replaced | |
AECM-88-0217, Corrected Special Rept 88-006:on 881021,inoperability of Accident Range Radiation Monitor Discovered.Caused by Damaged Cable Assembly.Cable Assembly Replaced | 4 November 1988 | Corrected Special Rept 88-006:on 881021,inoperability of Accident Range Radiation Monitor Discovered.Caused by Damaged Cable Assembly.Cable Assembly Replaced | |
AECM-88-217, Special Rept 88-004:on 881021,containment Ventilation Exhaust Accident Range Radiation Monitor Removed from Svc. Erratic Readings Observed During Surveillance.Caused by Damaged Cable Assembly.Channel 2 Tube Replaced | 4 November 1988 | Special Rept 88-004:on 881021,containment Ventilation Exhaust Accident Range Radiation Monitor Removed from Svc. Erratic Readings Observed During Surveillance.Caused by Damaged Cable Assembly.Channel 2 Tube Replaced | |
AECM-88-0181, Special Rept 88-005/0:on 880829,post-accident Monitoring Instrument for Standby Gas Treatment B Subsystem Exhaust Declared Inoperable & Left Inoperable for More than 72 H. Caused by Time Spent to Procure Replacement Part | 12 September 1988 | Special Rept 88-005/0:on 880829,post-accident Monitoring Instrument for Standby Gas Treatment B Subsystem Exhaust Declared Inoperable & Left Inoperable for More than 72 H. Caused by Time Spent to Procure Replacement Part | Grab sample |
AECM-88-0156, Final Special Rept on Events Re Interaction of Activities Associated W/Units 2 & 1,including Control of Chlorine Stored in Unit 2 Controlled Area & Leakage of Const Water Sys in Control Bldg | 9 August 1988 | Final Special Rept on Events Re Interaction of Activities Associated W/Units 2 & 1,including Control of Chlorine Stored in Unit 2 Controlled Area & Leakage of Const Water Sys in Control Bldg | New Resident Inspector |