Duke Energy Sites Annual Assessment Meeting Presentation Slides April 23, 2024
ML24100A806
Person / Time
Site: Oconee, Mcguire, Catawba, Harris, Brunswick, Robinson, McGuire  Duke Energy icon.png
Issue date: 04/09/2024
From: Sarah Temple
NRC/RGN-II/DRP/RPB1
To:
References
Download: ML24100A806 (1)


Text

2023 ANNUAL ASSESSMENT

CATAWBA MCGUIRE OCONEE BRUNSWICK

Reactor Oversight Process Nuclear Regulatory Commission Region II

HARRIS ROBINSON

If unable to hear audio, dial 301-576-2978, passcode: 250834548#

PURPOSE

Discuss licensee Address findings and Information Meeting with performance in 2023 Performance Indicators a Q&A Session

If unable to hear audio, dial 301-576-2978, passcode: 250834548#

2 AGENDA

  • Review Reactor Oversight Process
  • Annual Assessment Summary
  • Catawba Nuclear Station
  • McGuire Nuclear Station
  • Oconee Nuclear Station
  • Brunswick Steam Electric Plant
  • Shearon Harris Nuclear Power Plant
  • H.B. Robinson Steam Electric Plant
  • Closing Remarks
  • NRC available for public questions

If unable to hear audio, dial 301-576-2978, passcode: 250834548#

3

Introductions

Eric Stamm - Branch Chief for Catawba, McGuire, & Oconee

Matthew Fannon - Branch Chief for Brunswick & Harris

Ryan Taylor - Acting Branch Chief for Robinson

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 4 NRC Mission Statement

The NRC licenses and regulates the nation's civilian use of radioactive materials to provide reasonable assurance of adequate protection of public health and safety and to promote the common defense and security and to protect the environment

If unable to hear audio, dial 301-576-2978, passcode: 250834548#5 NRC REACTOR OVERSIGHT PROCESS

1 2 NRC NRC 3

4

Implemented in each Involves inspection and Executed by regional and of the NRCs four assessment activities resident inspectors regions

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 6 Reactor Oversight Framework

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 7 Reactor Oversight Inputs and Oversight

INCREASING SAFET Y SIGNIFICANCE

GREEN WHITE Y E L LOW RED Performance Performance within an Performance outside Related cornerstone Signals a significant Indicators expected level; expected range; objectives are being met; reduction in safety Cornerstone objectives Cornerstone objectives Minimal reduction in the margin in the area are met are still being met safety margin measured Findings Very low safety or security Low to moderate safety Substantial safety or High safety or security significance or security significance security significance significance

Oversight Baseline Inspection Requires additional NRC Requires more NRC Requires most NRC oversight oversight oversight

INCREASING NRC OVERSIGHT

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 8 RESIDENT INSPECTOR PROGRAM

  • Resident inspectors live in the communities they serve
  • Perform inspections at nuclear power plants
  • Provide daily oversight of plant activities

If unable to hear audio, dial 301-576-2978, passcode: 250834548#

9 9 NRC Annual Assessment Summary

CATAWBA NUCLEAR STATION

If unable to hear audio, dial 301-576-2978, passcode: 250834548#10 Catawba Nuclear Station:

Introductions

  • Regional Personnel
  • Catawba Nuclear Station Resident Inspectors
  • David Rivard - Senior Resident Inspector
  • Anny Wang - Resident Inspector

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 11 Catawba Nuclear Station:

Annual Assessment Summary

Duke Energy operated the plant safely and in a manner that preserved the public health and safety and protected the environment

All findings associated with Catawba Nuclear Station in 2023 were Green 3 - Green non-cited violations

All Performance Indicators were Green

If unable to hear audio, dial 301-576-2978, passcode: 250834548#12 Catawba Nuclear Station:

Annual Assessment Summary

Catawba Units 1 and 2 remained in the Licensee Response Column of the NRCs ROP Action Matrix in all quarters of 2023

NRC plans to conduct routine baseline inspections at the Catawba Nuclear Station for 2023

If unable to hear audio, dial 301-576-2978, passcode: 250834548#13 NRC Annual Assessment Summary

MCGUIRE NUCLEAR STATION

If unable to hear audio, dial 301-576-2978, passcode: 250834548#14 McGuire Nuclear Station:

Introductions

  • Regional Personnel
  • McGuire Nuclear Station Resident Inspectors
  • Frank Young - Resident Inspector

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 15 McGuire Nuclear Station:

Annual Assessment Summary

  • Duke Energy operated the plant safely and in a manner that preserved the public health and safety and protected the environment
  • All findings associated with McGuire Nuclear Station in 2023 were Green
  • 4 - Green non-cited violations
  • All Performance Indicators were Green

If unable to hear audio, dial 301-576-2978, passcode: 250834548#16 McGuire Nuclear Station:

Annual Assessment Summary

  • McGuire Units 1 and 2 remained in the Licensee Response Column of the NRCs ROP Action Matrix for the last quarter of 2023
  • NRC plans to conduct routine baseline inspections at the McGuire Nuclear Station for 2024

If unable to hear audio, dial 301-576-2978, passcode: 250834548#17 NRC Annual Assessment Summary

OCONEE NUCLEAR STATION

If unable to hear audio, dial 301-576-2978, passcode: 250834548#18 Oconee Nuclear Station:

Introductions

  • Regional Personnel
  • Oconee Nuclear Station Resident Inspectors
  • Nick Smalley - Senior Resident Inspector
  • Evan Robinson - Resident Inspector

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 19 Oconee Nuclear Station:

Annual Assessment Summary

  • Duke Energy operated the plant safely and in a manner that preserved the public health and safety and protected the environment
  • All findings associated with Oconee Nuclear Station in 2023 were Green
  • 10 - Green non-cited violations
  • 1 - Green notice of violation
  • 1 - Green finding
  • 3 - traditional enforcement violations
  • All Performance Indicators were Green

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 20 NRC Annual Assessment Summary OCONEE NUCLEAR STATION

  • Oconee Units 1, 2, and 3 remained in the Licensee Response Column of the NRCs ROP Action Matrix for the last quarter of 2023
  • NRC plans to conduct routine baseline inspections at the Oconee Nuclear Station for 2024

If unable to hear audio, dial 301-576-2978, passcode: 250834548#

21 NRC Annual Assessment Summary

BRUNSWICK STEAM ELECTRIC PLANT

If unable to hear audio, dial 301-576-2978, passcode: 250834548#22 Brunswick Steam Electric Plant:

Introductions

  • Regional Personnel
  • Brunswick Steam Electric Plant Resident Inspectors
  • Coleman Curran - Resident Inspector

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 23 Brunswick Steam Electric Plant:

Annual Assessment Summary

  • Duke Energy operated the plant safely and in a manner that preserved the public health and safety and protected the environment
  • All findings associated with Brunswick Steam Electric Plant in 2023 were Green
  • 3 - Green non-cited violations
  • All Performance Indicators were Green

If unable to hear audio, dial 301-576-2978, passcode: 250834548#24 Brunswick Steam Electric Plant:

Annual Assessment Summary

  • Brunswick Steam Electric Plant Units 1 and 2 remained in the Licensee Response Column of the NRCs ROP Action Matrix for the last quarter of 2023
  • NRC plans to conduct routine baseline inspections at the Brunswick Steam Electric Plant for 2024

If unable to hear audio, dial 301-576-2978, passcode: 250834548#25 NRC Annual Assessment Summary

SHEARON HARRIS NUCLEAR POWER PLANT

If unable to hear audio, dial 301-576-2978, passcode: 250834548#26 Shearon Harris Nuclear Power Plant:

Introductions

  • Regional Personnel
  • Shearon Harris Nuclear Power Plant Resident Inspectors

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 27 Shearon Harris Nuclear Power Plant:

Annual Assessment Summary

  • Duke Energy operated the plant safely and in a manner that preserved the public health and safety and protected the environment
  • One Greater than Green violation was identified in 2023
  • The remaining findings associated with Shearon Harris Nuclear Power Plant in 2023 were Green
  • 6 - Green non-cited violations
  • 2 - Green findings
  • All Performance Indicators were Green

If unable to hear audio, dial 301-576-2978, passcode: 250834548#28 Shearon Harris Nuclear Power Plant:

Annual Assessment Summary

  • Shearon Harris Nuclear Power Plant Unit 1 transitioned into the Regulatory Response Column of the NRCs ROP Action Matrix due to a Greater-than -green finding identified in the security cornerstone in the 2nd quarter of 2023
  • On December 7, 2023, the NRC completed a supplemental inspection in accordance with Inspection Procedure 95001 and determined that completed or planned corrective actions were sufficient to address the performance issue that led to the Greater than Green finding
  • NRC plans to conduct routine baseline inspections at the Shearon Harris Nuclear Power Plant for 2024

If unable to hear audio, dial 301-576-2978, passcode: 250834548#29 NRC Annual Assessment Summary

H.B. ROBINSON STEAM ELECTRIC PLANT

If unable to hear audio, dial 301-576-2978, passcode: 250834548#30 H.B. Robinson Steam Electric Plant:

Introductions

  • Regional Personnel
  • H.B. Robinson Steam Electric Plant Resident Inspectors
  • Vanna Gaffney - Resident Inspector

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 31 H.B. Robinson Steam Electric Plant:

Annual Assessment Summary

  • Duke Energy operated the plant safely and in a manner that preserved the public health and safety and protected the environment
  • All findings associated with H.B. Robinson Steam Electric Plant in 2023 were Green
  • 5 - Green non-cited violations
  • 1 - Green finding
  • All Performance Indicators were Green

If unable to hear audio, dial 301-576-2978, passcode: 250834548#32 H.B. Robinson Steam Electric Plant:

Annual Assessment Summary

  • H.B. Robinson Steam Electric Plant Unit 2 was in the Licensee Response Column of the NRCs ROP Action Matrix for the entire 2023 assessment period
  • NRC plans to conduct routine baseline inspections at the H.B.

Robinson Steam Electric Plant for 2024

If unable to hear audio, dial 301-576-2978, passcode: 250834548#33 CONTACT THE NRC

Web: https://www.nrc.gov

Report an Emergency - 301-816-5100

Safety Concern or Allegations - 1-800- 695-7403 l allegation@nrc.gov

Questions/Information - OPA2.Resource@nrc.gov or 404-997-4417

If unable to hear audio, dial 301-576-2978, passcode: 250834548# 34 CONTACT THE RESIDENT INSPECTORS

Catawba NRC resident inspectors Brunswick NRC resident inspectors (404) 997-5134 (404) 997-5121 (404) 997-5131 (404) 997-5123 McGuire NRC resident inspectors Harris NRC resident inspectors (404) 997-5171 (404) 997-5151 (404) 997-5173 (404) 997-5153 Oconee NRC resident inspectors Robinson NRC resident inspectors (404) 997-5211 (404) 997-5221 (404) 997-5213 (404) 997-5223 (404) 997-5214

If unable to hear audio, dial 301-576-2978, passcode: 250834548#

35 NRC ON SOCIAL MEDIA

Twitter: https://twitter.com/nrcgov Facebook: https://www.facebook.com/nrcgov/

Instagram: https://www.instagram.com/nrcgov/

YouTube: https://www.youtube.com/user/NRCgov Flickr: https://www.flickr.com/photos/nrcgov/sets LinkedIn: https://www.linkedin.com/company/u-s--nuclear -regulatory-commission/

GovDelivery: https://service.govdelivery.com/accounts/USNRC/subscriber/new

If unable to hear audio, dial 301-576-2978, passcode: 250834548#

36 GENERAL QUESTIONS