Path Forward for NRC Review of RNP Topical Reports for SLR 1

May 22, 2024

AGENDA Pressurize Thermal Shock Screening Criteria 2

Purpose of Request for Topical Report Review and Approval Regulatory Path Summary of Topical Reports

PURPOSE Pressurize Thermal Shock Screening Criteria 3

To discuss path forward for review of topical reports Support timely submittal of the RNP SLR application in 2nd quarter 2025 Submit topical reports for NRC review/approval

  • Increase efficiency of SLR application review/approval
  • Allow staff to meet 18-month review schedule Provide demonstration of compliance to 10 CFR 50.61 for weld #W5214 for 70 Effective Full Power Years (i.e., 80 years of operation)
  • Utilize an acceptable methodology to meet PTS screening criteria

Regulatory Path Utilize an acceptable methodology in 10 CFR 50.61 to develop RTNDT for weld

  1. W5214.
  • 10 CFR 50.61(a)(5) - RTNDT(U) means the reference temperature for a reactor vessel material in the pre-service or unirradiated condition, evaluated according to the procedures in the ASME Code, Paragraph NB-2331 or other methods approved by the Director, Office of Nuclear Reactor Regulation.

Develop RTT0 with 2019 Edition ASME Subsection NB-2331(a)(5) based on fracture toughness.

Duke will illustrate in the SLR application that the RTNDT for weld #W5214 succeeds in satisfying the PTS screening criteria for 80 years.

4

Summary WCAP-18909 NP

Purpose:

Measure initial unirradiated fracture toughness-based reference temperature RTT0 for #W5214 weld material Develop T0 with fracture toughness test of unirradiated specimen

  • ASTM E1921 Develop material specific RTT0 with fracture toughness results

Duke will develop RTT0 for #W5214 and shows the PTS screening criterion are met for 80 years

  • RTNDT(U) = RTT0 = T0 + 35F + 2
  • RTPTS = RTT0 + Charpy Shift + Margin 5

Summary WCAP-18933 NP

Purpose:

Measure irradiated RTT0 for Robinson #W5214 weld material

  • Note: Duke will submit revised WCAP-18933 to focus review only on #W5214 material Develop irradiated T0 with fracture toughness test
  • ASTM E1921 Develop material specific RTT0 with fracture toughness results

Illustrate that the difference between the irradiated RTT0 and the Charpy-based RTPTS methods is minimal to demonstrate margin for the PTS screening criterion 6

Conclusion Provisions in 10 CFR 50.61(a)(5) allow the use of 2019 Edition ASME Subsection NB-2331(a)(5) to develop RTT0.

Duke requests review and approval of WCAP-18909 and WCAP-18933.

  • Duke will resubmit WCAP-18933 to limit NRC review and approval of only the material associated with the weld #W5214.

Duke will utilize these WCAPs as input to demonstrate weld material #W5214 satisfies the 10 CFR 50.61 screening criterion in the SLR application for 80 years (70 EFPY).

7

NRC Feedback NRC FEEDBACK 8