Terrapower - Meeting Summary - Specified Acceptable System Radionuclide Release Design Limit (Sarrdl)
ML24059A159
Person / Time
Site: 99902100
Issue date: 02/28/2024
From: Brusselmans R
NRC/NRR/DANU/UAL1
To: Jessup W
NRC/NRR/DANU/UAL1
References
EPID L-2021-LRM-0071
Download: ML24059A159 (1)


Text

February 28, 2024 MEMORANDUM TO:

William T. Jessup, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:

Roel A. Brusselmans, Project Manager /RA/

Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF THE JULY 11, 2023, PARTIALLY CLOSED MEETING WITH TERRAPOWER, LLC, TO DISCUSS THE SPECIFIED ACCEPTABLE SYSTEM RADIONUCLIDE RELEASE DESIGN LIMITS, FUNCTIONAL CONTAINMENT, AND HYPOTHETICAL ACCIDENTS FOR THE NATRIUM DESIGN (EPID NO. L-2021-LRM-0071)

Meeting Information:

Applicant: TerraPower, LLC (TerraPower)

Project No.: 99902100 Public Meeting Notice Agencywide Documents Access and Management System (ADAMS)

Accession No.: ML23192A450 Applicant Presentation Slides: ML23180A301 Meeting Attendees: See the enclosure for a list of meeting attendees.

CONTACT:

Roel A. Brusselmans, NRR/DANU (301) 415-0673

W. Jessup 2

Meeting Summary:

On July 11, 2023, the U.S. Nuclear Regulatory Commission (NRC) staff held a partially closed public meeting with TerraPower to provide the NRC staff with an overview of the Natrium designs proposed Specified Acceptable System Radionuclide Release Design Limits (SARRDLs), functional containment, and hypothetical accidents that would need to be considered under Title 10 of the Code of Federal Regulations (10 CFR) Section 50.34, Contents of applications; technical information. Participants included representatives from TerraPower, General Electric Hitachi, Bechtel, and members of the general public. The NRC staff conducted the meeting in accordance with NRC Management Directive 3.5, Attendance at NRC Staff-Sponsored Meetings (ML21180A271).

The NRC staff began the meeting with an introduction and explained that a portion of the meeting would be closed to the public to discuss proprietary information. During the public portion of the meeting, TerraPower gave an overview of the Natrium design including a discussion of project goals, plant overview, and graphics explaining the design. TerraPower personnel provided a general overview of SARRDLs, regulations surrounding SARRDLs, and how SARRDLs were applied in the Natrium design. The TerraPower team then explained the concept of a functional containment, how it is applied in the Natrium design, what performance criteria are associated with Natrium functional containment, and how the preliminary safety analysis report will address the functional containment approach. Finally, TerraPower staff outlined its proposed approach for analyzing hypothetical accidents to demonstrate that offsite doses are within the limits of 10 CFR 50.34.

The NRC staff asked about the source of tritium that is to be accounted for in the SARRDLs, as discussed on Slide 10. TerraPower responded that tritium is a result of ternary fission and the activation of boron used as a neutron absorber in control and shield assemblies.

Regarding the major accident examples provided on Slide 21 of the presentation, the NRC staff asked what initiator was considered for the reactivity insertion event and whether external events were considered as initiators. TerraPower replied that the event under consideration was an even core-wide increase in reactivity (such as would occur from an uncontrolled rod withdrawal). TerraPower noted that it was only considering internal events for the containment demonstration and, though external events could potentially result in a more significant reactivity insertion, these were still under development at the time of the meeting.

During the closed portion of the meeting, TerraPower provided additional details regarding SARRDLs, functional containment, and how it intends to meet the requirements under 10 CFR 50.34 for the Natrium design. The NRC staff asked questions about the functional containment boundary and assumptions regarding holdup, retention, and leakage of radionuclides in the functional containment analysis. TerraPower representatives and the NRC staff discussed the next steps for future interactions regarding the Natrium reactor design.

No regulatory decisions were made as a result of this meeting.

Enclosure:

List of Meeting Attendees cc: TerraPower Natrium via GovDelivery

W. Jessup 3

SUBJECT:

SUMMARY

OF THE JULY 11, 2023, PARTIALLY CLOSED MEETING WITH TERRAPOWER, LLC, TO DISCUSS THE SPECIFIED ACCEPTABLE SYSTEM RADIONUCLIDE RELEASE DESIGN LIMITS, FUNCTIONAL CONTAINMENT, AND HYPOTHETICAL ACCIDENTS FOR THE NATRIUM DESIGN (EPID NO. L-2021-LRM-0071)

DATED: FEBRUARY 28, 2024 DISTRIBUTION:

PUBLIC RidsNrrDanuUal1 Resource RidsNrrDanu Resource MSutton, NRR DAtkinson, NRR SDevlin-Gill, NRR RBrusselmans, NRR WJessup, NRR RAnzalone, NRR ASiwy, NRR CdeMessieres, NRR MHart, NRR JSchaperow, NRR SJones, NRR ADAMS Accession Number: [ML24059A159]

NRR-001 OFFICE NRR/DANU/UAL1:PM NRR/DANU/UAL1:PM NRR/DANU/UAL1:LA NRR/DANU/UAL1:BC NAME RBrusselmans MSutton DGreene WJessup DATE 10/20/2023 10/26/2023 11/2/2023 12/22/2023 OFFICE NRR/DANU/UAL1:PM NAME RBrusselmans DATE 2/28/2024 OFFICIAL RECORD COPY

Enclosure List of Meeting Attendees

SUMMARY

OF THE JULY 11, 2023, PARTIALLY CLOSED MEETING WITH TERRAPOWER, LLC, TO DISCUSS THE SPECIFIED ACCEPTABLE SYSTEM RADIONUCLIDE RELEASE DESIGN LIMITS, FUNCTIONAL CONTAINMENT, AND HYPOTHETICAL ACCIDENTS FOR THE NATRIUM DESIGN (EPID NO. L-2021-LRM-0071)

July 11, 2023 Name Organization Mallecia Sutton U.S. Nuclear Regulatory Commission (NRC)

Roel Brusselmans NRC Andrew Proffitt NRC Stephanie Devlin-Gill NRC Alex Siwy NRC Candace de Messieres NRC Michelle Hart NRC Jason Schaperow NRC Steve Jones NRC Reed Anzalone NRC George Wilson TerraPower, LLC (TerraPower)

Ryan Sprengel TerraPower Ian Gifford TerraPower Matthew Presson TerraPower Brian Johnson TerraPower Chris Forrest TerraPower Emily Young TerraPower Hugh Luo TerraPower Jong Chang TerraPower Nick Kellenberger TerraPower Joe LaPrad TerraPower Joe Thomas TerraPower Mike Montecalvo TerraPower Steve Kline Bechtel Tim Enfinger General Electric Hitachi