Letter Sequence Request |
---|
|
|
MONTHYEARML22140A0252022-05-20020 May 2022 Tn America, LLC, Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 0 Project stage: Request ML22224A0412022-08-12012 August 2022 Tn Americas, LLC, Submittal of Response to Request for Supplemental Information - Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 1 Project stage: Supplement ML22313A0462022-12-21021 December 2022 Letter-Review of Amd18 CoC No. 1004 Request for Additional Information Project stage: RAI ML23069A2882023-01-20020 January 2023 Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Proposed CoC 1004 Amendment 18 Appendix B Technical Specifications (Rev. 2) Project stage: Other ML23069A2862023-01-20020 January 2023 Description of Amendment 18 Changes Not Related to Request for Additional Information Project stage: Request ML23069A2852023-01-20020 January 2023 Blended Cement Impact Evaluation on Renewed CoC 1004 Project stage: Other ML23020A9212023-01-20020 January 2023 Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Request for Additional Information Non-Proprietary Responses Project stage: Request ML23027A0562023-01-27027 January 2023 Response to Request for Additional Information Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 3 (Docket No. 72-1004, CAC No. 001028, EPID: L-2022-LLA-0079) Project stage: Response to RAI ML23047A0282023-02-16016 February 2023 Supplemental Response to Request for Additional Information - Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 4 (Docket No. 72-1004, CAC No. 001028, EPID: L-2022- Project stage: Supplement ML23293A3042023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix a Project stage: Other ML23293A3032023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix B Project stage: Other ML23293A3022023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix C Project stage: Other ML23293A3012023-11-0808 November 2023 Final Certificate of Compliance for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel Project stage: Approval ML23293A3002023-11-0808 November 2023 Final Safety Evaluation Report for the Standardized Nuhoms Horizontal Modular Storage System for Irradiated Nuclear Fuel Project stage: Approval ML23293A2992023-11-0808 November 2023 Amendment No. 18 to Certificate of Compliance No. 1004 for the Standardized NUHOMS System (Docket No. 72-1004, CAC No. 001028, (Enterprise Project Identifier: L-2022-LLA-0079) Project stage: Other 2023-01-20
[Table View] |
|
---|
Category:Legal-Affidavit
MONTHYEARML23095A1012023-04-0505 April 2023 Tn Americas LLC, Third Supplemental Response to Request for Additional Information Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 6 ML23067A0772023-03-0808 March 2023 Tn Americas LLC, Second Supplemental Response to Request for Additional Information for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Non-Proprietary ML23020A9212023-01-20020 January 2023 Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Request for Additional Information Non-Proprietary Responses ML22334A2442022-11-30030 November 2022 Tn Americas LLC, Affidavit ML22140A0252022-05-20020 May 2022 Tn America, LLC, Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 0 ML22094A2082022-03-16016 March 2022 Meeting Slides Affidavit - Notarized ML21356A0322021-12-22022 December 2021 Tn Americas LLC, Supplemental Response to Request for Additional Information - Proposed Alternative to the ASME Code, NG-4230 Tack Welds for Renewed Certificate of Compliance No. CoC 1004, Amendment Nos. 13, 14, 15, 16 and 17 ML21253A1052021-09-10010 September 2021 Proposed Alternative to the ASME Code, NG-4230 Tack Welds, Docket 72-1004, CoC 1004, for Recent Amendments ML21215A5592021-08-0303 August 2021 Tn Americas LLC, NUH-003, Updated Final Safety Analysis Report (UFSAR) for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel, Revision 20 ML21022A3962021-01-22022 January 2021 NUH-003, Updated Final Safety Analysis Report (UFSAR) for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel, Revision 19 ML20366A1062020-12-29029 December 2020 Tn Americas LLC Updated Licensing Plans ML20255A2062020-09-11011 September 2020 Tn America, LLC - Response to Request for Additional Information - Application for Amendment 17 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 1 (Docket No. 72-1004, CAC No. 001028, EPID: L- ML17363A2772017-12-14014 December 2017 Tn Americas LLC - Response to First Request for Additional Information on Application for Amendment 15 to Standardized Nuhoms for Spent Fuel Storage Casks, Revision 2, Enclosures 1,3,4,& 5 2023-04-05
[Table view] Category:Letter
MONTHYEARML23293A2992023-11-0808 November 2023 Amendment No. 18 to Certificate of Compliance No. 1004 for the Standardized NUHOMS System (Docket No. 72-1004, CAC No. 001028, (Enterprise Project Identifier: L-2022-LLA-0079) ML23284A0642023-10-11011 October 2023 Supplement to Submittal of Biennial Reports of 72.48 Evaluations Performed for the Standardized NUHOMS System, Certificate of Compliance (CoC) 1004, for the Periods 07/26/2016 to 07/25/2018 and 7/28/2020 to 7/27/2022, Docket 72-1004 ML23206A0172023-09-29029 September 2023 Congressional Letters: List of Approved Spent Fuel Storage Casks: Tn Americas LLC Standardized NUHOMS Horizontal Modular Storage System, Certificate of Compliance No. 1004, Renewed Amendment No.18 ML23095A1012023-04-0505 April 2023 Tn Americas LLC, Third Supplemental Response to Request for Additional Information Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 6 ML23067A0772023-03-0808 March 2023 Tn Americas LLC, Second Supplemental Response to Request for Additional Information for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Non-Proprietary ML23047A0282023-02-16016 February 2023 Supplemental Response to Request for Additional Information - Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 4 (Docket No. 72-1004, CAC No. 001028, EPID: L-2022- ML23030A6682023-01-30030 January 2023 Independent Spent Fuel Storage Installation ((Isfsi) - Submittal of Cask Registration for Spent Fuel Storage ML23027A0562023-01-27027 January 2023 Response to Request for Additional Information Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 3 (Docket No. 72-1004, CAC No. 001028, EPID: L-2022-LLA-0079) ML23020A9212023-01-20020 January 2023 Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Request for Additional Information Non-Proprietary Responses ML22355A0932023-01-0606 January 2023 Orano Tn Americas - USNRC Inspection Report 72-1004/2022-203 ML23005A1712023-01-0404 January 2023 Independent Spent Fuel Storage Installation (Isfsi), Submittal of Cask Registration for Spent Fuel Storage ML22313A0462022-12-21021 December 2022 Letter-Review of Amd18 CoC No. 1004 Request for Additional Information ML22224A0412022-08-12012 August 2022 Tn Americas, LLC, Submittal of Response to Request for Supplemental Information - Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 1 ML22165A2782022-07-0505 July 2022 Inspection Report 2022 Orano Corporate Inspection ML22140A0252022-05-20020 May 2022 Tn America, LLC, Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 0 NG-22-0047, Registration of Independent Spent Fuel Installation Storage Cask and Notification of Permanent Removal of All Spent Fuel Assemblies from the Spent Fuel Pool2022-04-11011 April 2022 Registration of Independent Spent Fuel Installation Storage Cask and Notification of Permanent Removal of All Spent Fuel Assemblies from the Spent Fuel Pool NG-22-0042, Registration of Independent Spent Fuel Installation Storage Casks2022-04-0808 April 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0030, Registration of Independent Spent Fuel Installation Storage Casks2022-03-23023 March 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22063B1652022-03-16016 March 2022 U.S. Nuclear Regulatory Commission Inspection Report No. 721004/2022201 and 07201042/2022201 NG-22-0025, Registration of Independent Spent Fuel Installation Storage Casks2022-03-0808 March 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0021, Registration of Independent Spent Fuel Installation Storage Casks2022-02-24024 February 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0014, Registration of Independent Spent Fuel Installation Storage Casks2022-02-10010 February 2022 Registration of Independent Spent Fuel Installation Storage Casks ML22025A1692022-02-0303 February 2022 Code Alternative Approval Letter for Certain CoC 1004 Amendments NG-22-0009, Registration of Independent Spent Fuel Installation Storage Casks2022-01-20020 January 2022 Registration of Independent Spent Fuel Installation Storage Casks NG-22-0001, Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61BTH Type 2 Dry Shielded Canister2022-01-0606 January 2022 Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61BTH Type 2 Dry Shielded Canister ML21356A0322021-12-22022 December 2021 Tn Americas LLC, Supplemental Response to Request for Additional Information - Proposed Alternative to the ASME Code, NG-4230 Tack Welds for Renewed Certificate of Compliance No. CoC 1004, Amendment Nos. 13, 14, 15, 16 and 17 NG-21-0038, Registration of Independent Spent Fuel Installation Storage Casks2021-12-22022 December 2021 Registration of Independent Spent Fuel Installation Storage Casks NG-21-0035, Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61 Bth Type 2 Dry Shielded Canister2021-12-10010 December 2021 Supplement to Exemption Request for Failed Fuel Can Weight in a Certificate of Compliance 1004 Renewed Amendment 17 61 Bth Type 2 Dry Shielded Canister ML21323A0572021-11-19019 November 2021 Tn Americas, LLC - Response to Request for Additional Information - Proposed Alternative to the ASME Code, NG-4230 Tack Welds for Renewed Certificate of Compliance No. CoC 1004, Amendment Nos. 13, 14, 15, 16 and 17 ML21292A3312021-11-0303 November 2021 CoC 1004 - Proposed ASME Code Alternative RAI 1 - Letter ML21253A1052021-09-10010 September 2021 Proposed Alternative to the ASME Code, NG-4230 Tack Welds, Docket 72-1004, CoC 1004, for Recent Amendments ML21215A5592021-08-0303 August 2021 Tn Americas LLC, NUH-003, Updated Final Safety Analysis Report (UFSAR) for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel, Revision 20 ML21179B0272021-06-28028 June 2021 Independent Spent Storage Installation, Submittal of Cask Registration for Spent Fuel Storage ML21168A2662021-06-17017 June 2021 Independent Spent Fuel Storage Installation (ISFSI) - Submittal of Cask Registration for Spent Fuel Storage ML21109A3272021-05-0505 May 2021 Issuance of Certificate of Compliance No. 1004, Renewed Amendment No. 17, for the Standardized NUHOMS System ML21067A6302021-03-0808 March 2021 Orano Tn - Replacement Pages for NUH-003, Updated Final Safety Analysis Report (UFSAR) for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel, Revision 19 ML21022A3962021-01-22022 January 2021 NUH-003, Updated Final Safety Analysis Report (UFSAR) for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel, Revision 19 ML20366A1062020-12-29029 December 2020 Tn Americas LLC Updated Licensing Plans PLA-7900, Registration for the Use of Dry Fuel Storage Modules F-6, F-7, and F-8 (PLA-7900)2020-10-14014 October 2020 Registration for the Use of Dry Fuel Storage Modules F-6, F-7, and F-8 (PLA-7900) NG-20-0083, Registration of Independent Spent Fuel Installation Storage Casks2020-10-12012 October 2020 Registration of Independent Spent Fuel Installation Storage Casks PLA-7896, Registration for the Use of Dry Fuel Storage Modules G-8, F-4, and F-5 (PLA-7896)2020-09-28028 September 2020 Registration for the Use of Dry Fuel Storage Modules G-8, F-4, and F-5 (PLA-7896) NG-20-0082, Registration of Independent Spent Fuel Installation Storage Casks2020-09-28028 September 2020 Registration of Independent Spent Fuel Installation Storage Casks ML20255A2062020-09-11011 September 2020 Tn America, LLC - Response to Request for Additional Information - Application for Amendment 17 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 1 (Docket No. 72-1004, CAC No. 001028, EPID: L- PLA-7890, Registration for the Use of Dry Fuel Storage Modules G-6 and G-7 (PLA-7890)2020-09-10010 September 2020 Registration for the Use of Dry Fuel Storage Modules G-6 and G-7 (PLA-7890) ML20245E2542020-08-31031 August 2020 Amendment No. 17 to Certificate of Compliance No. 1004 for the Standardized NUHOMS System - Request for Additional Information PLA-7888, Talen Energy - Susquehanna Steam Electric Station, Registration for the Use of Dry Fuel Storage Modules G-4 and G-5, PLA-78882020-08-25025 August 2020 Talen Energy - Susquehanna Steam Electric Station, Registration for the Use of Dry Fuel Storage Modules G-4 and G-5, PLA-7888 ML20226A0652020-08-21021 August 2020 Standardized NUHOMS Hsm, Amendment 16, (Graded Approach) Finalization Letter (Docket No. 72-1004) NG-20-0067, Registration of Independent Spent Fuel Installation Storage Casks2020-08-12012 August 2020 Registration of Independent Spent Fuel Installation Storage Casks RNP-RA/20-0234, Independent Spent Fuel Storage Installation, Registration of Use of Spent Fuel Casks2020-07-23023 July 2020 Independent Spent Fuel Storage Installation, Registration of Use of Spent Fuel Casks ML20188A1372020-07-0202 July 2020 Acceptance Review of Request for Amendment No. 17 to Certificate of Compliance No. 1004 for the Standardized NUHOMS System 2023-09-29
[Table view] Category:License-Dry Cask
MONTHYEARML23293A3012023-11-0808 November 2023 Final Certificate of Compliance for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel ML23293A3022023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix C ML23293A3032023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix B ML23293A3042023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix a ML22203A1192022-05-20020 May 2022 Amendment 18 Proposed CoC and Technical Specifications ML22140A0252022-05-20020 May 2022 Tn America, LLC, Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 0 ML21109A3282021-05-0404 May 2021 CoC 1004 Amendment No. 17 CoC ML21109A3292021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix a ML21109A3302021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Table of Contents ML21109A3312021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Text ML21109A3322021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Tables ML21109A3332021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Figures ML21109A3342021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix C ML20308A4872020-12-21021 December 2020 Proposed CoC 1004 Amendment No. 17 CoC ML20230A3182020-08-21021 August 2020 Final Certificate of Compliance No. 1004, Amendment 16, Model No. Standardized Nuhoms(R) Horizontal Storage Module (Hsm) ML18347B3352018-12-14014 December 2018 Final CoC 1004 Amendment 15 Certificate L-MT-18-067, Thirty (30) Day Notification Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel2018-11-0909 November 2018 Thirty (30) Day Notification Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel ML18228A5312018-10-25025 October 2018 ADAMS Reference 1: Proposed CoC No. 1004 Amendment No. 15 CoC (Memorandum to K. Morgan-Butler User Need for Rulemaking for the Standardized Nuhoms System, CoC No. 1004, Amendment No. 15) ML18088A1802018-03-22022 March 2018 to Application for Amendment 15 to Standardized Nuhoms Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Supplemental Response to First Request for Additional Information ONS-2017-066, Registration for Use of General License Spent Fuel Cask Numbers 147 and 1482017-09-20020 September 2017 Registration for Use of General License Spent Fuel Cask Numbers 147 and 148 ML17222A1502017-07-17017 July 2017 ISFSI - Cask Registration for Spent Fuel Storage Under Amended Certificate of Compliance No. 1004 L-MT-16-050, Thirty-Day Notification for Dry Shielded Canister MNP-61 BTH-1-B-2-016 Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel2016-10-20020 October 2016 Thirty-Day Notification for Dry Shielded Canister MNP-61 BTH-1-B-2-016 Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel PLA-7520, Registration for Use of Dry Fuel Storage Module D-15 and Thermal Performance Assessment2016-09-19019 September 2016 Registration for Use of Dry Fuel Storage Module D-15 and Thermal Performance Assessment ML16245A2172016-08-23023 August 2016 ISFSI - Submittal of Cask Registration for Spent Fuel Storage, Cask Certificate No. 1004 ML15190A3442015-06-22022 June 2015 Independent Fuel Storage Installation - Submittal of Cask Registration for Spent Fuel Storage PLA-7252, Registration for the Use of Dry Fuel Storage Module D-82014-11-17017 November 2014 Registration for the Use of Dry Fuel Storage Module D-8 ML13252A1422013-08-30030 August 2013 General License 30-day Cask Registration Notification and First System Thermal Performance Assessment ML11327A1442011-11-18018 November 2011 General License 30-day Cask Registration Notification ML0611604131996-01-31031 January 1996 Registration of Dry Spent Fuel Storage Cask Use and Cask Heat Transfer Characteristics 2023-11-08
[Table view] Category:ISFSI
MONTHYEARML23293A3012023-11-0808 November 2023 Final Certificate of Compliance for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel ML23293A3022023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix C ML23293A3032023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix B ML23293A3042023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix a ML22203A1192022-05-20020 May 2022 Amendment 18 Proposed CoC and Technical Specifications ML22140A0252022-05-20020 May 2022 Tn America, LLC, Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 0 ML21109A3282021-05-0404 May 2021 CoC 1004 Amendment No. 17 CoC ML21109A3292021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix a ML21109A3302021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Table of Contents ML21109A3312021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Text ML21109A3322021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Tables ML21109A3332021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Figures ML21109A3342021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix C ML20308A4872020-12-21021 December 2020 Proposed CoC 1004 Amendment No. 17 CoC ML20230A3182020-08-21021 August 2020 Final Certificate of Compliance No. 1004, Amendment 16, Model No. Standardized Nuhoms(R) Horizontal Storage Module (Hsm) ML18347B3352018-12-14014 December 2018 Final CoC 1004 Amendment 15 Certificate L-MT-18-067, Thirty (30) Day Notification Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel2018-11-0909 November 2018 Thirty (30) Day Notification Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel ML18228A5312018-10-25025 October 2018 ADAMS Reference 1: Proposed CoC No. 1004 Amendment No. 15 CoC (Memorandum to K. Morgan-Butler User Need for Rulemaking for the Standardized Nuhoms System, CoC No. 1004, Amendment No. 15) ML18088A1802018-03-22022 March 2018 to Application for Amendment 15 to Standardized Nuhoms Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Supplemental Response to First Request for Additional Information ONS-2017-066, Registration for Use of General License Spent Fuel Cask Numbers 147 and 1482017-09-20020 September 2017 Registration for Use of General License Spent Fuel Cask Numbers 147 and 148 ML17222A1502017-07-17017 July 2017 ISFSI - Cask Registration for Spent Fuel Storage Under Amended Certificate of Compliance No. 1004 L-MT-16-050, Thirty-Day Notification for Dry Shielded Canister MNP-61 BTH-1-B-2-016 Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel2016-10-20020 October 2016 Thirty-Day Notification for Dry Shielded Canister MNP-61 BTH-1-B-2-016 Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel PLA-7520, Registration for Use of Dry Fuel Storage Module D-15 and Thermal Performance Assessment2016-09-19019 September 2016 Registration for Use of Dry Fuel Storage Module D-15 and Thermal Performance Assessment ML16245A2172016-08-23023 August 2016 ISFSI - Submittal of Cask Registration for Spent Fuel Storage, Cask Certificate No. 1004 ML15190A3442015-06-22022 June 2015 Independent Fuel Storage Installation - Submittal of Cask Registration for Spent Fuel Storage PLA-7252, Registration for the Use of Dry Fuel Storage Module D-82014-11-17017 November 2014 Registration for the Use of Dry Fuel Storage Module D-8 ML13252A1422013-08-30030 August 2013 General License 30-day Cask Registration Notification and First System Thermal Performance Assessment ML11327A1442011-11-18018 November 2011 General License 30-day Cask Registration Notification ML0611604131996-01-31031 January 1996 Registration of Dry Spent Fuel Storage Cask Use and Cask Heat Transfer Characteristics 2023-11-08
[Table view] Category:(Amend) DKT 72
MONTHYEARML23293A3012023-11-0808 November 2023 Final Certificate of Compliance for the Standardized NUHOMS Horizontal Modular Storage System for Irradiated Nuclear Fuel ML23293A3022023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix C ML23293A3032023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix B ML23293A3042023-11-0808 November 2023 Final NUHOMS 1004 Amendment 18, Appendix a ML22203A1192022-05-20020 May 2022 Amendment 18 Proposed CoC and Technical Specifications ML22140A0252022-05-20020 May 2022 Tn America, LLC, Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 0 ML21109A3282021-05-0404 May 2021 CoC 1004 Amendment No. 17 CoC ML21109A3292021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix a ML21109A3302021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Table of Contents ML21109A3312021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Text ML21109A3322021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Tables ML21109A3332021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix B Figures ML21109A3342021-05-0404 May 2021 CoC 1004 Amendment No. 17 Appendix C ML20308A4872020-12-21021 December 2020 Proposed CoC 1004 Amendment No. 17 CoC ML20230A3182020-08-21021 August 2020 Final Certificate of Compliance No. 1004, Amendment 16, Model No. Standardized Nuhoms(R) Horizontal Storage Module (Hsm) ML18347B3352018-12-14014 December 2018 Final CoC 1004 Amendment 15 Certificate L-MT-18-067, Thirty (30) Day Notification Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel2018-11-0909 November 2018 Thirty (30) Day Notification Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel ML18228A5312018-10-25025 October 2018 ADAMS Reference 1: Proposed CoC No. 1004 Amendment No. 15 CoC (Memorandum to K. Morgan-Butler User Need for Rulemaking for the Standardized Nuhoms System, CoC No. 1004, Amendment No. 15) ML18088A1802018-03-22022 March 2018 to Application for Amendment 15 to Standardized Nuhoms Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Supplemental Response to First Request for Additional Information ONS-2017-066, Registration for Use of General License Spent Fuel Cask Numbers 147 and 1482017-09-20020 September 2017 Registration for Use of General License Spent Fuel Cask Numbers 147 and 148 ML17222A1502017-07-17017 July 2017 ISFSI - Cask Registration for Spent Fuel Storage Under Amended Certificate of Compliance No. 1004 L-MT-16-050, Thirty-Day Notification for Dry Shielded Canister MNP-61 BTH-1-B-2-016 Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel2016-10-20020 October 2016 Thirty-Day Notification for Dry Shielded Canister MNP-61 BTH-1-B-2-016 Pursuant to 10 CFR 72.212, Conditions of General License Issued Under 10 CFR 72.210, for the Storage of Spent Fuel PLA-7520, Registration for Use of Dry Fuel Storage Module D-15 and Thermal Performance Assessment2016-09-19019 September 2016 Registration for Use of Dry Fuel Storage Module D-15 and Thermal Performance Assessment ML16245A2172016-08-23023 August 2016 ISFSI - Submittal of Cask Registration for Spent Fuel Storage, Cask Certificate No. 1004 ML15190A3442015-06-22022 June 2015 Independent Fuel Storage Installation - Submittal of Cask Registration for Spent Fuel Storage PLA-7252, Registration for the Use of Dry Fuel Storage Module D-82014-11-17017 November 2014 Registration for the Use of Dry Fuel Storage Module D-8 ML13252A1422013-08-30030 August 2013 General License 30-day Cask Registration Notification and First System Thermal Performance Assessment ML11327A1442011-11-18018 November 2011 General License 30-day Cask Registration Notification ML0611604131996-01-31031 January 1996 Registration of Dry Spent Fuel Storage Cask Use and Cask Heat Transfer Characteristics 2023-11-08
[Table view] |
Text
May 20, 2022 E-60447 Orano TN 7160 Riverwood Drive Suite 200 U. S. Nuclear Regulatory Commission Columbia, MD 21046 Attn: Document Control Desk USA Tel: 410-910-6900 One White Flint North Fax: 434-260-8480 11555 Rockville Pike Rockville, MD 20852
Subject:
Application for Amendment 18 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks, Revision 0 (Docket No. 72-1004)
In accordance with 10 CFR 72.244, TN Americas LLC herewith submits its application to amend Certificate of Compliance (CoC) No. 1004 for the Standardized NUHOMS System. The scope of Amendment 18 is described in Enclosure 2.
Enclosure 3 includes a mark-up of proposed changes to the CoC document.
Enclosure 4 provides a complete revision to the CoC Appendix A Inspections, Tests and Evaluations (ITE) with proposed changes tracked. Enclosure 5 provides a complete revision to the CoC Appendix B Technical Specifications (TS) with proposed changes tracked. Enclosure 6 provides a complete revision to the CoC Appendix C ASME Code Alternatives with proposed changes tracked. The proprietary version of the Updated Final Safety Analysis Report (UFSAR) changed pages and drawings associated with Amendment 18 are included as Enclosure 7 with a footer on each changed page annotated as 72-1004 Amendment 18, Revision 0, May 2022. New drawings are indicated as Revision 0A, and revised drawings show alpha-numeric revision numbers and clouds surrounding the changed drawing information. The public version of these UFSAR changed pages and drawings is provided as Enclosure 8.
In order to document the evaluation of Amendment 18 structures, systems, and components (SSCs) for extended operation, Enclosure 9 provides the impact of these SSCs on CoC 1004 renewal. Enclosure 10 provides a listing of computer files contained on the Enclosure 11 hard drive being submitted in support of this amendment. Enclosure 11 contains file formats and sizes not allowed by the NRC EIE application process, so they are provided separately on one computer drive.
Enclosures transmitted herein contain SUNSI. When separated from enclosures, this transmittal document is decontrolled.
E-60447 Document Control Desk Page 2 of 2 Certain portions of this submittal include proprietary information, which may not be used for any purpose other than to support the NRC staffs review of the application. In accordance with 10 CFR 2.390, TN Americas LLC is providing an affidavit (Enclosure 1), specifically requesting that this proprietary information be withheld from public disclosure.
TN Americas LLC looks forward to working with the NRC staff on this amendment application and requests that the staff assign appropriate priority for review of this application in order for Amendment 18 to become effective by November 2023.
Should you have any questions regarding this submittal, please do not hesitate to contact Mr.
Douglas Yates at 434-832-3101, or me at 410-910-6859.
Prakash Narayanan Chief Technical Officer cc: Chris Allen (NRC DFM)
Enclosures:
- 1. Affidavit Pursuant to 10 CFR 2.390
- 2. Description, Justification, and Evaluation of Amendment 18 Changes
- 3. Proposed Certificate of Compliance No. 1004 Amendment 18, Revision 0 Markup
- 4. Proposed CoC Appendix A Inspections, Tests, and Evaluations, CoC 1004 Amendment 18, Revision 0
- 5. Proposed CoC Appendix B Technical Specifications, CoC 1004 Amendment 18, Revision 0
- 6. Proposed CoC Appendix C ASME Code Alternatives, CoC 1004 Amendment 18, Revision 0
- 7. Proposed Amendment 18, Revision 0 Changes to the Standardized NUHOMS System Updated Final Safety Analysis Report (Proprietary Version)
- 8. Proposed Amendment 18, Revision 0 Changes to the Standardized NUHOMS System Updated Final Safety Analysis Report (Public Version)
- 9. Amendment 18 Impacts on CoC 1004 Renewal
- 10. Listing of Computer Files Contained in Enclosure 11
- 11. Certain Computer Files Associated with Certificate of Compliance 1004 Amendment 18 (Proprietary) (contained on one hard drive)
Enclosure 1 to E-60447 AFFIDAVIT PURSUANT TO 10 CFR 2.390 TN Americas LLC )
State of North Carolina) ss.
County of Guilford )
I, Prakash Narayanan, depose and say that I am the Chief Technical Officer of TN Americas LLC, duly authorized to execute this affidavit, and have reviewed or caused to have reviewed the information that is identified as proprietary and referenced in the paragraph immediately below. I am submitting this affidavit in conformance with the provisions of 10 CFR 2.390 of the Commission's regulations for withholding this information.
The information for which proprietary treatment is sought meets the provisions of paragraph (a) (4) of Section 2.390 of the Commission's regulations. The information is contained in Enclosures 7 and 11, as listed below:
- Enclosure 11 - Certain computer files associated with Proposed CoC 1004 Amendment 18 This document has been appropriately designated as proprietary.
T have personal knowledge of the criteria and procedures utilized by TN Americas LLC in designating information as a trade secret, privileged or as confidential commercial or financial information.
Pursuant to the provisions of paragraph (b) (4) of Section 2.390 of the Commission's regulations, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure, included in the above referenced document, should be withheld.
- 1) The information sought to be withheld from public disclosure involves portions of the UFSAR, and analysis computer files, all related to the design of the Standardized NUHOMS dry spent fuel storage system, which are owned and have been held in confidence by TN Americas LLC.
- 2) The information is of a type customarily held in confidence by TN Americas LLC, and not customarily disclosed to the public. TN Americas LLC has a rational basis for determining the types of information customarily held in confidence by it.
- 3) Public disclosure of the information is likely to cause substantial harm to the competitive position of TN Americas LLC, because the information consists of descriptions of the design of dry spent fuel storage systems, the application of which provide a competitive economic advantage. The availability of such information to competitors would enable them to modify their product to better compete with TN Americas LLC, take marketing or other actions to improve their product's position or impair the position of TN Americas LLC's product, and avoid developing similar data and analyses in support of their processes, methods or apparatus.
Further the deponent sayeth not.
Prakash Narayanan Chief Technical Officer, TN Americas LLC North Carolina Guilford County Sub c ibed and sworn before me this 10 th day of May, 2022.
My Commission Expires ..l..!2.JJJf..J~f
Enclosure 2 to E-60447 DESCRIPTION, JUSTIFICATION, AND EVALUATION OF AMENDMENT 18 CHANGES INTRODUCTION The scope of Amendment 18 to the Standardized NUHOMS Certificate of Compliance (CoC)
No. 1004 includes the changes described below.
Change No. 1:
Provide for a 24PTH improved basket design using staggered plates similar to EOS-37PTH to simplify construction, reduce weight and improve fabricability. In CoC Appendix B Technical Specifications (TS), Table 1-1l, PWR Fuel Specification for the Fuel to be Stored in the NUHOMS - 24PTH DSC weight limit was increased from 1682 lbs to 1715 lbs for fuel assembly plus CC based on the lighter Type 3 basket. In addition, the total weight of the FFC and all its contents is deleted. For consistency with the two other DSCs that contain a similar total weight of the FFC plus all its contents statement, this statement is also deleted from Table 1-1e for the 32PT DSC and from Table 1-1t for the 61BTH DSC. CoC Appendix A, Inspections, Tests and Evaluations (ITE), has a new section added to address the high strength low alloy steel used in the new Type 3 basket design for the 24PTH DSC. In addition, transfer cask does rate values were updated and simplified for the 24PTH DSC.
The CoC Appendix A (ITE), Appendix B TS, Appendix C ASME Code Alternatives and Updated Final Safety Analysis (UFSAR) have been revised accordingly, as described further in this enclosure. The CoC, appendices and UFSAR were revised to differentiate 24PTH Type 3 basket requirements from the existing 24PTH Type 1 and Type 2 basket requirements as necessary.
Lastly, the CoC 1004 renewal impact evaluation in Enclosure 9, with the main focus on the new Type 3 basket SSC changes, uses the latest Interim Staff Guidance on fuel retrievability as documented in ISG-2 Revision 2. As a result, Chapters 12 and P.1 have been updated to reflect ISG-2 Revision 2.
Change No. 2:
Deletion of Appendix A ITE requirement for initial HSM delta T measurement with a loaded DSC.
Change No. 3:
Clarifies Appendix B TS Section 4.3.2 language related to transfer casks with liquid neutron shields regarding the OS197L TC, which is significantly different than other TC models.
Change No. 4:
Updated Appendix C ASME Code Alternatives Table C-12 to add code alternative NG-4231.1 as approved on February 3, 2022, ML22025A169 Page 1 of 8
Enclosure 2 to E-60447 Change No. 5:
Change Appendix B TS Section 4.3.2, first paragraph, by removing a reference to 10 CFR Part 20 to clarify language indicating that the site specific evaluation in accordance with 10 CFR 72.212 is to demonstrate compliance with 10 CFR 72.104.
Change No. 6:
Clarify TC/DSC annulus draining language in Appendix B TS Section 4.3.2 within the last paragraph.
Change No. 7:
Clarify in Appendix B TS LCO 3.1.3 that there is no transfer time limit associated with the 24PTH-S-LC DSC, consistent with existing UFSAR analysis.
Change No. 8:
Editorially correct CoC name/address information by adding missing space between 7160 and Riverwood Drive.
Change No. 9:
Incorporate administrative controls during short duration independent spent fuel storage installation (ISFSI) handling operations that are unanalyzed for tornado hazards in accordance with the guidance contained in NRC EGM 22-001, "Enforcement Discretion for Noncompliance of Tornado Hazards Protection Requirements at Independent Spent Fuel Storage Installations".
These changes are in UFSAR Chapter 3, the operational portions of Chapters 5, K.8, M.8, P.8, T.8, U.8, Y.8, and Z.8 and in Chapter 12.
DESCRIPTION OF THE CHANGES Changes to the Standardized NUHOMS CoC The table below provides proposed changes to the CoC pages, a brief description of the subject and/or change, and a reference to the scope item from Section 1.0 that relates to the change or changes.
Scope CoC page CoC Number Description Item Amendment number changed to 18 and 1 N/A Amendment effective Date changed to none TBD.
Added space between 7160 and 1 N/A 8 Riverwood in address.
Update ASME Code Requirements for 3 N/A 1 24PTH DSC for Type 3 Basket Page 2 of 8
Enclosure 2 to E-60447 Scope CoC page CoC Number Description Item 2 through 5 header Amendment number changed to 18 none Changes to the Standardized NUHOMS CoC 1004 Appendix A Inspections, Tests, and Evaluations The table below provides proposed changes to the ITE pages, a brief description of the subject and/or change, and a reference to the scope item from Section 1.0 that relates to the change or changes.
Scope ITE page ITE Number Description Item Cover Page N/A Amendment number changed to 18. none TOC/LOT/LOF N/A Table of Contents, etc. automated updates. none 2 2.0 Adds new basket type to table 1 3 New 2.4 HSLA Steel for Basket Structure 1 Clarifies requirements for 24PTH Type 1 and 2 baskets. The High Seismic option is 6 3.1.8 1 not applicable to 24PTH DSC with Type 3 basket.
6 3.2 Table Update and simplify dose rates for 24PTH 1 8 3.3.2 Table Update 24PTH-S-LC dose rates 1 HSM Maximum Air Exit Temperature with a 10 4.4 2 Loaded DSC is deleted.
Changes to the Standardized NUHOMS CoC 1004 Appendix B Technical Specifications The table below provides proposed changes to the TS pages, a brief description of the subject and/or change, and a reference to the scope item from Section 1.0 that relates to the change or changes.
Scope TS page TS Number Description Item Cover Page N/A Amendment number changed to 18. none TOC/LOT/LOF N/A Table of Contents, etc. automated updates. none Deleted pointer to ITE Section 4.4 which is 2-1 2.1.1 2 being deleted.
Page 3 of 8
Enclosure 2 to E-60447 Scope TS page TS Number Description Item Clarification to Time Limit for Completion of DSC Transfer for 24PTH-S-LC for existing basket Type 2. Add time limit for completion of transfer for 24PTH-S, 3-7 3.1.3 1, 7 24PTH-L and 24PH-S-LC DSCs with new Type 3 basket. Removed "DSC" from each row, as this is redundant to the column heading.
By removing mention of 10 CFR Part 20, 4.3.2, this clarifies the language to indicate that 4-3 the evaluation pursuant to 72.212 is to 5 1 paragraph st confirm limits of 72.104 are satisfied for the site.
Clarify and split out the requirements that 4-3, 4-4 4.3.2 apply to the OS197L TC, versus other TCs 3 with liquid neutron shields.
Clarify language to indicate that the neutron shield level should be monitored 4.3.2, when draining the TC/DSC annulus as 4-3, 4-4 6 Last paragraph those drain locations are close to each other, but removed the language regarding draining the DSC cavity.
Delete total weight of FFC plus contents T-5 Table 1-1e 1 sentence for failed fuel (32PT).
Delete total weight of FFC plus contents T-19 Table 1-1l 1 sentence for failed fuel (24PTH).
Increase the weight limit from 1682 lbs to T-20 Table 1-1l 1715 lbs for Maximum Assembly plus CC 1 Weight for Type 3 basket.
T-21 Table 1-1l Update decay heat for Type 3 basket. 1 Update 24PTH Intact Fuel Table to reflect T-25, T-26 Table 1-1p 1 new basket type.
Update 24PTH Damaged Fuel Table to T-27 Table 1-1q 1 reflect new basket type.
Update 24PTH Damaged/Failed Fuel T-28, T-29 Table 1-1q1 1 Table to reflect new basket type.
T-30 Table 1-1r Update 24PTH Poison Plate Table 1 Delete total weight of FFC plus contents T-32 Table 1-1t 1 sentence for failed fuel (61BTH).
F-18 Figure 1-15 Update notes to reflect Type 3 basket. 1 Page 4 of 8
Enclosure 2 to E-60447 Scope TS page TS Number Description Item Update figure title to include Type 3 F-19 Figure 1-15a 1 basket.
Changes to the Standardized NUHOMS CoC 1004 Appendix C ASME Code Alternatives The table below provides proposed changes to the TS pages, a brief description of the subject and/or change, and a reference to the scope item from Section 1.0 that relates to the change or changes.
ASME Code Alt ASME Code Alt Scope Description page Number Item Cover Page N/A Amendment number changed to 18. none LOT/Tables N/A Amendment number changed to 18. none Updated to differentiate 24PTH Type 1 and C-1 List of Tables 1 2 baskets from Type 3 Updated to indicate items are for 24PTH C-14, C-15 Table C-8 1 Type 1 and 2 baskets C-23 NG-4231.1 Addition of Approved Code Alternative 4 Changes to the Standardized NUHOMS CoC 1004 UFSAR Enclosure 7 (Proprietary version) and Enclosure 8 (Public version) provide proposed Amendment 18 changed pages for the Standardized NUHOMS UFSAR. Amendment 18 proposed UFSAR changes are tracked by italicized text and revision bars.
The following paragraphs discuss the UFSAR areas proposed for change, based on the changes described above. Editorial changes to correct spelling, grammar, etc. are also made to the changed UFSAR pages where appropriate.
In support of Change 1, changes are made to UFSAR Chapters 1, References; 12, Aging Management; Appendix P.1, General Discussion; P.2, Principal Design Criteria; P.3, Structural Evaluation; P.4, Thermal Evaluation; P.5, Shielding Evaluation; P.6, Criticality Evaluation; P.8, Operating Systems; P.9, Acceptance Tests and Maintenance Program; P.10, Radiation Protection and P.11, Accident Analyses.
In support of Change 2, a change was made to UFSAR Chapter 10, Operating Controls and Limits, to delete the ITE Bases section for ITE 4.4.
Changes 3 through 8 do not require UFSAR changes.
Page 5 of 8
Enclosure 2 to E-60447 In support of Change 9, changes are made to UFSAR Section 3.2.1, Tornado Wind Loadings; operating procedures associated with DSC insertion or retrieval at the ISFSI in Chapters 5; Appendices K.8, M.8, P.8, T.8, U.8, Y.8, Z.8, and UFSAR Section 12.3.
JUSTIFICATION OF THE NEED FOR THESE CHANGES Change 1 provides for a 24PTH improved basket design using staggered plates similar to EOS-37PTH to simplify construction, reduce weight and improve fabricability. In conjunction with the improved basket design, the weight limit was increased from 1682 lbs to 1715 lbs for Maximum Assembly plus CC Weight as a result of the weight reduction associated with the new EOS based staggered plate Type 3 basket design. In order to provide a consistent and appropriate level of detail related to fuel weights, the total weight of FFC plus all its contents requirement is deleted from Table 1-1l. For completeness, total weight requirement is also deleted from Tables 1-1e and 1-1t as well. The resulting level of detail is consistent with maximum assembly weight requirements contained in other CoC TS such as CoC 1029 and CoC 1042. Lastly, new Section 2.4 was added to Appendix A ITE to provide a discussion on the high strength low alloy steel that will be used in the new basket design. In addition, transfer cask dose rate values were updated and simplified for the 24PTH DSC. The CoC, Appendix A (ITE), Appendix B Technical Specifications (TS), Appendix C ASME Code Alternatives and Updated Final Safety Analysis (UFSAR) have been revised accordingly, as well, to differentiate 24PTH Type 3 basket requirements from the existing 24PTH basket requirements as necessary.
Justification for Removal of the Weight of the Failed Fuel Can (FFC) Plus All Its Contents The weight of the FFC plus all its contents requirement is removed from the TS, but is retained without any changes within the UFSAR. Eliminating the weight of the FFC plus it contents does not modify the system behavior beyond the allowable bounds since:
- 1. The total weight of the FFC is mostly driven by the fuel assembly weight, which is already specified within the Technical Specifications.
- 2. The weight limit of the fuel assembly also includes the weight of the non-fuel assembly hardware. It is extremely unlikely that all of the fuel assemblies within a DSC are loaded to the maximum limit, which provides additional margin to the total weight limit.
- 3. The total weight requirement remains within the UFSAR to convey the design requirements and to ensure that any modifications to the FFC remain within the applicable bounds of the UFSAR evaluation.
- 4. There are only a few locations within each DSC wherein failed fuel assemblies are stored. If the weight of the FFC exceeds the maximum specified within the UFSAR, it is evaluated using the design change and 10 CFR 72.48 process. This will ensure that all design criteria including stress allowable limits and 10CFR 72.48 requirements are satisfied.
It should also be noted that removing the FFC weight limitation from the Technical Specification is consistent with more recent approvals such as the 32PTH1 DSC in the same CoC, 32PTH2 in Amendment 3 to CoC 1029 and EOS-37PTH in Amendment 1 to CoC 1042.
Page 6 of 8
Enclosure 2 to E-60447 Change 2 removes CoC 1004 Appendix A ITE Section 4.4, HSM Maximum Air Temperature with a Loaded DSC. The purpose of this measurement was to ensure that the system is performing as designed by comparing the measured thermal performance of the cask against that predicted by the UFSAR thermal analysis for the same heat load. Operating experience from loading over 800 DSCs over more than two decades has resulted in no known delta T temperature issues and demonstrates that this requirement realistically no longer appears to be necessary and newer systems such as the CoC 1042 TS do not require this one time measurement after initial DSC loading.
Change 3 clarifies Appendix B TS Section 4.3.2 language related to transfer cask liquid neutron shields through formatting to more clearly indicate what applies to the OS197L TC.
Change 4 updates the Appendix C ASME Code Alternatives Table C-12 to add recently approved code alternative NG-4231.1. NRC approved this code alternative on February 3, 2022. ML22025A169 Change 5 improves the clarity of the Radiation Protection Program discussion by revising text in first paragraph to reflect that the evaluation pursuant to 72.212 is to confirm the limits of 72.104 for the actual site conditions.
Change 6 clarifies draining requirements language in the TS to indicate that the neutron shield level should be monitored when draining the TC/DSC annulus as those two drain locations are close to each other, but the NS level does not need to be monitored when draining the DSC cavity since the DSC cavity drain is on the opposite end of the DSC from the annulus and neutron shield drains.
Change 7 improves the clarity of the CoC 1004 Appendix B TS and is based on the existing thermal performance of the 24PTH-S-LC DSC during transfer operations in the Standardized TC. As noted in UFSAR Section P.4.6.5.2, the thermal evaluation of 24PTH-S-LC DSC with a heat load of 24 kW within the Standardized TC is performed for the following ambient conditions:
- Maximum normal ambient temperature of 100 °F with insolation, and
- Minimum normal ambient temperature of 0 °F without insolation The results of these analyses are reported in UFSAR Table P.4-14 as results for HLZC 5 and in UFSAR Table P.4-17. As shown in the UFSAR Table P.4-14, there are no time limits specified for HLZC 5 unlike the columns for HLZC 1 and 4 which demonstrates that there are no time limits required.
Change 8 corrects a formatting issue with the CoC address information.
Change 9 incorporates administrative controls during short duration ISFSI handling operations that are unanalyzed for tornado hazards in accordance with the guidance contained in EGM 22-001. These changes are in UFSAR Chapter 3, the operational portions of Chapters 5, K.8, M.8, P.8, T.8, U.8, Y.8, Z.8, and Chapter 12 and provide a defense-in-depth approach that precludes ISFSI handling operations during periods of adverse weather involving tornado hazards, or when adverse weather involving tornado hazards is predicted, and contains compensatory measures to place important to safety SSCs in an analyzed condition, as necessary.
Page 7 of 8
Enclosure 2 to E-60447 EVALUATION OF CHANGES TN has evaluated the changes described above for structural, thermal, shielding, confinement and criticality adequacy, as applicable, and has concluded that these changes to the Standardized NUHOMS System have no significant effect on safety.
The evaluations for the changes are included in Enclosure 7 (Proprietary version) and (Public version) of this submittal.
Page 8 of 8