CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Q iv is the release rate of radionuclides, i, in gaseous effluents from all vent releases (µCi/sec)
To comply with this specification, the effluent radiation monitor has a setpoint corresponding to an offsite total body dose rate at or below the limit (see Part II Section 2.6). In addition, compliance is assessed by calculating offsite total body dose rate based on periodic samples obtained per station procedures.
4.2.1.2 Noble Gas: Skin Dose Rate RECS limits the skin dose rate due to noble gases in gaseous effluents released from a site to areas at and beyond the site boundary to less than or equal to a dose rate of 3000 mrem/yr at all times. (See Part I Section 12.4.1)
In accordance with NUREG-0133 methodology, the skin dose rate due to noble gases released in gaseous effluents is calculated by the following expression:
D Skin = i[(Li*(/Q)s + 1.1*Bi)* Q is + (Li + 1.1*Mi)*(( /Q)v*Q iv)] (4-2) where:
D Skin is the instantaneous dose rate to the skin due to radioactive materials (noble gasses) released in gaseous effluents from the site (mrem/yr)
Li is the skin dose factor due to beta emissions for each identified noble gas radionuclide (mrem*m3/yr*µCi). Reference table 4-13.
(/Q)s is the highest calculated annual average relative concentration for areas at or beyond the unrestricted area boundary for elevated stack releases (sec/m3).
1.1 is the unit conversion constant to convert air dose to skin dose (mrem/mrad).
Bi is the constant for long term releases (greater than 500 hr/yr) for each identified noble gas radionuclide accounting for the gamma radiation from the elevated finite plume (mrad*sec/yr*µCi).
Q is is the release rate of radionuclides, i, in gaseous effluents from a free standing (elevated) stack (µCi/sec).
Mi is the air dose factor due to gamma emissions for each identified noble gas radionuclide (mrad*m3/yr*µCi). Reference table 4-13.
II.4-3 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual
(/Q)v is the highest calculated annual average relative concentration for areas at or beyond the unrestricted area boundary for vent releases (sec/m3).
Q iv is the release rate of radionuclides, i, in gaseous effluents from all vent releases (µCi/sec).
To comply with this specification, gaseous effluent radiation monitors have setpoints corresponding to an offsite skin dose rate at or below the limit (see Part II Section 2.6). In addition, compliance is assessed by calculating offsite skin dose rate based on periodic samples obtained per station procedures.
4.2.1.3 Non-Noble Gas Radionuclides: Organ Dose Rate RECS limits the dose rate to any organ, due to radioactive materials in gaseous effluents released from a site to areas at and beyond the site boundary, to less than or equal to a dose rate of 1500 mrem/yr (See Part I Section 12.4.1)
Typically the adult is considered to be the limiting receptor in calculating dose rate to organs due to inhalation of non-noble gas radionuclides in gaseous effluents.
In accordance with NUREG 0133 Methodology, the dose rate to any adult organ due to inhalation is calculated by the following expression:
D inhalja = iPIi*[(/Q)s*Q is + (/Q)v*Q iv] (4-3)
D inhaljais the instantaneous dose rate to organ (j) of an individual in ager group (a) due to inhalation of non noble gas radioactive materials released in gaseous effluents from the site (mrem/yr)
PIi is the inhalation dose rate factor for each identified non noble gas radionuclide, i, (mrem*m3/yr*µCi). Pi inhalation dose rate factors are calculated in accordance with the following:
PIi = K(BR)DFAi where:
PIi is the inhalation dose rate factor (mrem*m3/yr*µCi).
K is a constant of unit conversion = 1E+06 (pCi/µCi).
BR is the breathing rate of the age group of interest (m3/yr).
DFAi is the inhalation dose factor (mrem/pCi)
II.4-4 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual
(/Q)s is the highest calculated annual average relative concentration for areas at or beyond the unrestricted area boundary for elevated stack releases (sec/m3).
Q is is the release rate of radionuclides, i, in gaseous effluents from a free standing (elevated) stack (µCi/sec).
(/Q)v is the highest calculated annual average relative concentration for areas at or beyond the unrestricted area boundary for vent releases (sec/m3).
Q iv is the release rate of radionuclides, i, in gaseous effluents from all vent releases (µCi/sec).
RECS requires the dose rate due to non-noble gas radioactive materials in airborne effluents be determined to be within the above limit in accordance with a sampling and analysis program specified in Part I Table R12.4.1-1.
The adult organ dose rate due to inhalation is calculated in each sector at the location of the highest offsite /Q (see Table 4-3). The result for the sector with the highest organ inhalation dose rate is compared to the limit.
4.2.2 Time Averaged Dose from Noble Gas 4.2.2.1 Gamma Air Dose RECS limits the gamma air dose due to noble gas effluents released from each reactor unit to areas at and beyond the unrestricted area boundary to the following:
- Less than or equal to 5 mrad per calendar quarter.
- Less than or equal to 10 mrad per calendar year.
In accordance with NUREG 0133 Methodology, the gamma air dose due to noble gases released in gaseous effluents is calculated by the following expression:
D = 3.17E-08*i{Mi[(/Q)v*Qiv+(/q)v*qiv]+[Bi*Qis+bi*qis]} (4-4) where:
D is the dose to air due to gamma radiation from noble gas radiation released in gaseous effluents (mrad) 3.17E-08 is a conversion constant (yr/sec).
Mi is the air dose factor due to gamma emissions for each identified noble gas radionuclide (mrad*m3/yr*µCi). Reference table 4-13.
II.4-5 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual
(/Q)v is the highest calculated annual average relative concentration for areas at or beyond the unrestricted area boundary for long term (greater than 500 hr/yr) vent releases (sec/m3).
Qiv is the average release of noble gas radionuclides in gaseous effluents, i, for long term (greater than 500 hr/yr) vent releases (µCi).
(/q)v is the relative concentration for areas at or beyond the unrestricted area boundary for short term (equal to or less than 500 hr/yr) vent releases (sec/m3).
qiv is the average release of noble gas radionuclides, i, in gaseous releases, i, for short term (equal to or less than 500 hr/yr) vent releases (µCi).
Bi is the constant for long term releases (greater than 500 hr/yr) for each identified noble gas radionuclide accounting for the gamma radiation from the elevated finite plume (mrad*sec/yr*µCi).
Qis is the average release of noble gas radionuclides in gaseous effluents, i, for long term (greater than 500 hr/yr) releases from a free standing (elevated) stack (µCi).
bi is the constant for short term releases (equal to or less than 500 hr/yr) for each identified noble gas radionuclide accounting for the gamma radiation from the elevated finite plume (mrad*sec/yr*µCi).
qis is the average release of noble gas radionuclides in gaseous effluents, i, for short term (equal to or less than 500 hr/yr) releases from a free standing (elevated) stack (µCi).
RECS Section 12.4.2, RSR 12.4.2.1, and Section 12.4.5, RSR 12.4.5.1 require determination of cumulative and projected gamma air dose contributions due to noble gases for the current calendar quarter and the current calendar year at least once per 31 days.
Gamma air dose is calculated for the sector with the highest offsite (/Q) and is compared with the RECS limits on gamma air dose.
For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.
II.4-6 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual 4.2.2.2 Beta Air Dose RECS limits beta air dose due to noble gases in gaseous effluents released from each reactor unit to areas at and beyond the unrestricted area boundary to the following:
- Less than or equal to 10 mrad per calendar quarter.
- Less than or equal to 20 mrad per calendar year.
In accordance with NUREG 0133 Methodology, the beta air dose due to noble gases released in gaseous effluents is calculated by the following expression:
D = 3.17E-08*i{Ni[(/Q)v*Qiv + (/q)v*qiv + (/Q)s*Qis + (/q)s*qis]} (4-5) where:
D is the dose to air due to beta radiation from noble gas radiation released in gaseous effluents (mrad) 3.17E-08 is a conversion constant (yr/sec).
Ni is the air dose factor due to beta emissions for each identified noble gas radionuclide (mrad*m3/yr*µCi). Reference table 4-13.
(/Q)v is the highest calculated annual average relative concentration for areas at or beyond the unrestricted area boundary for long term (greater than 500 hr/yr) vent releases (sec/m3).
Qiv is the average release of noble gas radionuclides in gaseous effluents, i, for long term (greater than 500 hr/yr) vent releases (µCi).
(/q)v is the relative concentration for areas at or beyond the unrestricted area boundary for short term (equal to or less than 500 hr/yr) vent releases (sec/m3).
qiv is the average release of noble gas radionuclides, i, in gaseous releases, i, for short term (equal to or less than 500 hr/yr) vent releases (µCi).
(/Q)s is the highest calculated annual average relative concentration for areas at or beyond the unrestricted area boundary for long term (greater than 500 hr/yr) releases from a free standing (elevated) stack (sec/m3).
Qis is the average release of noble gas radionuclides in gaseous effluents, i, for long term (greater than 500 hr/yr) releases from a free standing (elevated) stack (µCi).
II.4-7 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual
(/q)s is the relative concentration for areas at or beyond the unrestricted area boundary for short term (equal to or less than 500 hr/yr) releases from a free standing (elevated) stack (sec/m3).
qis is the average release of noble gas radionuclides in gaseous effluents, i, for short term (equal to or less than 500 hr/yr) releases from a free standing (elevated) stack (µCi).
RECS Section 12.4.2, RSR 12.4.2.1, and Section 12.4.5, RSR 12.4.5.1 require determination of cumulative and projected beta air dose contributions due to noble gases for the current calendar quarter and the current calendar year at least once per 31 days.
Beta air dose is calculated for the sector with the highest offsite (/Q) and is compared with the RECS limit on beta air dose.
For a release attributable to a processing or effluent system shared by more than one reactor unit, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.
4.2.2.3 Whole Body Dose The total (or whole) body dose, to any receiver is due, in part, to gamma radiation emitted from radioactivity in airborne effluents. This component is added to others to demonstrate compliance to the requirements of 40CFR190 and 10CFR20.
In accordance with NUREG 0133 Methodology, the total body dose component due to gamma radiation from noble gases released in gaseous effluents is calculated by the following expression:
DTB = 3.17E-08
- t
- D TB (4-6) where:
DTB is the total (or whole) body dose due to gamma radiation from noble gas radionuclides released in gaseous effluents (mrem) 3.17E-08 is a conversion constant (yr/sec).
t is the number of seconds in the period of interest (sec)
D TB is the instantaneous dose rate to the total body due to radioactive materials (noble gasses) released in gaseous effluents from the site (mrem/yr)
II.4-8 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual The total body dose is also calculated for the 40CFR190 and 10CFR20 compliance assessments. In some cases, the total body dose may be required in 10CFR50 Appendix I assessments (See Part II Table 1-1).
4.2.2.4 Skin Dose There is no regulatory requirement to evaluate skin dose. However, this component is evaluated for reference as there is skin dose design objective contained in 10CFR50 Appendix I. Note that in the unlikely event that if beta air dose guideline is exceeded, then the skin dose will require evaluation.
In accordance with NUREG 0133 Methodology, the part of skin dose due to noble gases released in gaseous effluents is calculated by the following expression:
DSkin = 3.17E-08
- t
- D Skin (4-7) where:
DSkin is the skin dose due to beta and gamma radiation from noble gas radionuclides released in gaseous effluents (mrem) 3.17E-08 is a conversion constant (yr/sec).
t is the number of seconds in the period of interest (sec)
D Skin is the instantaneous dose rate to the total body due to radioactive materials (noble gasses) released in gaseous effluents from the site (mrem/yr) 4.2.3 Time Averaged Dose from Non-Noble Gas Radionuclides RECS provides the following limits, based on 10CFR50 Appendix I, on the dose to a member of the public from specified non-noble gas radionuclides in gaseous effluents released from each reactor unit to areas at and beyond the unrestricted area boundary:
- Less than or equal to 7.5 mrem to any organ during any calendar quarter
- Less than or equal to 15 mrem to any organ during any calendar year The individual dose components are also required as part of the 40CFR190 assessments and combined as part of the 10CFR20 assessment (Part II Table 1-1).
The dose due to radionuclides deposited on the ground is considered to be a component of the deep dose equivalent for 10CFR20 and 40CFR190 compliance and an organ (and total body) dose component for 10CFR50 Appendix I compliance.
II.4-9 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual The dose is calculated for releases in the time period under consideration.
In accordance with NUREG-0133 methodology, time averaged dose from non noble gas radionuclides can be calculated using the following equation and the pathway specific R dose factor defined in the subsections below:
DNNG = 3.17E-08*i{Ri[Ws*Qis + ws*qis + Wv*Qiv + wv*qiv]} (4-8)
Where:
DNNG is the committed dose equivalent (CDE) due to non noble gas radionuclides in gaseous effluents (mrem) 3.17E-08 is a conversion constant (yr/sec).
Ri is the dose factor for each identified radionuclide, i (m2*mrem*sec/yr*µCi for (D/Q) calculations, or mrem*m3/yr*µCi for (/Q) calculations)
W is the dispersion parameter for estimating the dose to an individual at the controlling location for long term (greater than 500 hr/yr) releases:
W = (/Q) for the inhalation pathway (sec/m3)
W = (D/Q) for the food and ground pathways (m-2)
Qi is the release of radionuclides, radioactive materials in particulate form, and radionuclides other than noble gasses in gaseous effluents, i, for long term (greater than 500 hr/yr) releases (µCi).
w is the dispersion parameter for estimating the dose to an individual at the controlling location for long term (equal to or less than 500 hr/yr) releases:
w = (/q) for the inhalation pathway (sec/m3) w = (D/q) for the food and ground pathways (m-2) qi is the release of radionuclides, radioactive materials in particulate form, and radionuclides other than noble gasses in gaseous effluents, i, for short term (equal to or less than 500 hr/yr) releases (µCi).
RECS Section 12.4.3, RSR 12.4.3.1, and Section 12.4.5, RSR 12.4.5.1 require cumulative and projected dose contributions for the current calendar quarter and the current calendar year for the specified non-noble gas radionuclides in airborne effluents to be determined at least once per 31 days.
II.4-10 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual To comply with this specification, each nuclear power station obtains and analyzes samples in accordance with the radioactive gaseous waste or gaseous effluent sampling and analysis program in its RETS. For each organ of each age group considered (adult/teenager/child/infant), the dose for each pathway is calculated in every sector (except for sectors over water bodies). The calculation is based on the location assumptions discussed below in conjunction with the pathway equations. For each organ of each age group, the doses are summed in each sector over all pathways.
The result for the sector with the highest total dose is compared to the limit. The values used for (X/Q) and (D/Q) are shown in Table 4-3 through Table 4-5 and correspond to the applicable pathway location.
For a release attributable to a processing or effluent system shared by more than one reactor, the dose due to an individual unit is obtained by proportioning the effluents among the units sharing the system.
The dose evaluated is also included as part of the 10CFR20 and 40CFR190 assessment (See Part II Section 5).
4.2.3.1 Ground Plane The dose due to ground deposition of radioactivity is considered to be a total body dose component.
Dose due to the ground plane pathway can be calculated using the methodology described in 4.2.3 and the ground plane dose factor (RGi) defined below:
RGi = K'*K"*SF*DFGi*(1-exp(-i*t))/i) (4-9) where:
RGi is the ground plane dose factor for each identified radionuclide, i (m2*mrem*sec/yr*µCi)
K' is a constant of unit conversion = 1E+06 (pCi/µCi)
K" is a constant of unit conversion = 8760 (hr/yr)
SF is the shielding factor (dimensionless)
DFGi is the ground plane dose conversion factor for the ith radionuclide (mrem*m3/hr*pCi) i is the decay constant for the ith radionuclide (sec-1) t is the exposure time (sec)
II.4-11 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Note that ground plane dose factors are only given for the total body and no age group. Doses to other organs are assumed to be equal to the total body dose. All age groups are assumed to receive the same dose.
The deep dose equivalent (DDE) due to ground deposition is determined for each sector using the highest calculated offsite value of D/Q for that sector.
The ground plane exposure pathway is considered to exist at all locations.
4.2.3.2 Inhalation The committed dose equivalent (CDE) due to the inhalation pathway can be calculated using the methodology described in 4.2.3 and the inhalation dose factor (RIi) defined below:
RIi = K'*(BR)a*(DFAi)a (4-10) where:
RIi is the inhalation dose factor for each identified radionuclide, i (mrem*m3/yr*µCi)
K' is a constant of unit conversion = 1E+06 (pCi/µCi)
(BR)a is the breathing rate of the receptor age group (a) (m3/yr)
(DFAi)a is the organ inhalation dose factor for the receptor of age group (a) for the ith radionuclide (mrem/pCi)
The inhalation exposure pathway is considered to exist at all locations.
The CDE due to inhalation is determined for each sector using the highest calculated offsite value of X/Q for that sector.
4.2.3.3 Ingestion: Vegetation Food ingestion pathway doses are calculated at locations indicated by the land use census survey. If no real pathway exists within 5 miles of the station, the cow-milk pathway is assumed to be located at 5 miles. Food pathway calculations are not made for sectors in which the offsite regions near the station are over bodies of water.
Dose due to the vegetation ingestion pathway can be calculated using the methodology described in 4.2.3 and the vegetation dose factor (RVi) defined below:
II.4-12 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual RVi = K'*[r/(Yv*(i+w))]*DFLia*[(ULa*fL*exp(-i*tL)) + (USa*fg*exp(-i*th))] (4-11a) or in the case of tritium:
RVi = K'
- K * [(ULa
- fL) + (USa
- fg)] *(DFLi)a * [0.75(0.5/H)] (4-11b) or in the case of C-14:
RVi = K'
- K * [(ULa
- fL) + (USa
- fg)] *(DFLi)a
- p * [0.11 / 0.16] (4-11c) where:
RVi is the vegetation dose factor for each identified radionuclide, i (m2*mrem*sec/yr*µCi)
K' is a constant of unit conversion = 1E+06 (pCi/µCi) r is the fraction of deposited activity retained on vegetation/grass (dimensionless)
Yv is the vegetation areal density (kg/m2) i is the decay constant for the ith radionuclide (sec-1) w is the decay constant for removal of activity on leaf and plant surfaces by weathering = 5.73E-07 (sec-1)
(DFLi)a is the organ ingestion dose factor for the ith radionuclide for the receptor in age group (a) (mrem/pCi)
ULa is the consumption rate of fresh leafy vegetation by the receptor in age group (a) (kg/yr) fL is the fraction of the annual intake of fresh leafy vegetation grown locally (dimensionless) tL is the average time between harvest of leafy vegetation and its consumption (sec)
USa is the consumption rate of stored vegetation by the receptor in age group (a) (kg/yr) fg is the fraction of the annual intake of stored vegetation grown locally (dimensionless)
II.4-13 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual th is the average time between harvest of stored vegetation and its consumption (sec)
K is a constant of unit conversion = 1E+03 (g/kg)
H is the absolute humidity of the atmosphere (g/m3) 0.75 is the fraction of total feed that is water (dimensionless) 0.5 is the ratio of the specific activity of the feed water to atmospheric water (dimensionless) p is the fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of total annual release time (for C-14 atmospheric releases) to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.
0.11 is the fraction of total plant mass that is natural carbon (dimensionless) 0.16 is the concentration of natural carbon in the atmosphere (g/m3) 4.2.3.4 Ingestion: Milk Dose due to the milk ingestion pathway can be calculated using the methodology described in 4.2.3 and the milk dose factor (RCi) defined below:
RCi = K'*((QF*Uap)/(i+w))*Fm*r*(DFLi)a*[((fp*fs)/Yp) +
(((1-fp*fs)*exp(-i*th))/Ys)]*exp(-i*tf) (4-12a) or in the case of tritium:
RCi = K'*K*Fm*QF*Uap*(DFLi)a*[0.75(0.5/H)] (4-12b) or in the case of C-14:
RCi = K'
- K
- Fm
- QF
- Uap * (DFLi)a
- p * [0.11 / 0.16] (4-12c) where:
RCi is the milk dose factor for each identified radionuclide, i (m2*mrem*sec/yr*µCi or mrem*m3/yr*µCi)
K' is a constant of unit conversion = 1E+06 (pCi/µCi)
II.4-14 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual QF is the animals consumption rate (kg/day, wet weight)
Uap is the receptors milk consumption rate for age group (a) (L/yr) i is the decay constant for the ith radionuclide (sec-1) w is the decay constant for removal of activity on leaf and plant surfaces by weathering = 5.73E-07 (sec-1)
Fm is the stable element transfer coefficient (day/L) r is the fraction of deposited activity retained on vegetation/grass (dimensionless)
(DFLi)a is the organ ingestion dose factor for the ith radionuclide for the receptor in age group (a) (mrem/pCi) fp is the fraction of the year that the animal is on pasture (dimensionless) fs is the fraction of the feed that is pasture grass while the animal is on pasture (dimensionless)
Yp is the agricultural productivity by unit area of pasture feed grass (kg/m2) th is the transport time from pasture, to harvest, to animal, to milk, to receptor (sec)
Ys is the agricultural productivity by unit area of stored feed (kg/m2) tf is the transport time from pasture, to animal, to milk, to receptor (sec)
K is a constant of unit conversion = 1E+03 (g/kg)
H is the absolute humidity of the atmosphere (g/m3) 0.75 is the fraction of total feed that is water (dimensionless) 0.5 is the ratio of the specific activity of the feed water to atmospheric water (dimensionless) p is the fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of total annual release time (for C-14 atmospheric releases) to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.
II.4-15 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual 0.11 is the fraction of total plant mass that is natural carbon (dimensionless) 0.16 is the concentration of natural carbon in the atmosphere (g/m3) 4.2.3.5 Ingestion: Meat Dose due to the meat ingestion pathway can be calculated using the methodology described in 4.2.3 and the meat dose factor (RMi) defined below:
RMi = K'*((QF*Uap)/(i+w))*Ff*r*DFLia*[((fp*fs)/Yp) +
(((1-fp*fs)*exp(-i*th))/Ys)]*exp(-i*tf) (4-13a) or in the case of tritium:
RMi = K'
- K
- Ff
- QF
- Uap * (DFLi)a * [0.75(0.5/H)] (4-13b) or in the case of C-14:
RMi = K'
- K
- Ff
- QF
- Uap * (DFLi)a
- p *[0.11 / 0.16] (4-13c) where:
RMi is the meat dose factor for each identified radionuclide, i (m2*mrem*sec/yr*µCi)
K' is the animals consumption rate (kg/day, wet weight)
QF is the animals consumption rate (kg/day, wet weight)
Uap is the receptors meat consumption rate for age group (a) (kg/yr) i is the decay constant for the ith radionuclide (sec-1) w is the decay constant for removal of activity on leaf and plant surfaces by weathering = 5.73E-07 (sec-1)
Ff is the stable element transfer coefficient (day/kg) r is the fraction of deposited activity retained on vegetation/grass (dimensionless)
(DFLi)a is the organ ingestion dose factor for the ith radionuclide for the receptor in age group (a) (mrem/pCi) fp is the fraction of the year that the animal is on pasture (dimensionless)
II.4-16 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual fs is the fraction of the feed that is pasture grass while the animal is on pasture (dimensionless)
Yp is the agricultural productivity by unit area of pasture feed grass (kg/m2) th is the transport time from crop field to receptor (sec)
Ys is the agricultural productivity by unit area of stored feed (kg/m2) tf is the transport time from pasture to receptor (sec)
K is a constant of unit conversion = 1E+03 (g/kg)
H is the absolute humidity of the atmosphere (g/m3) 0.75 is the fraction of total feed that is water (dimensionless) 0.5 is the ratio of the specific activity of the feed water to atmospheric water (dimensionless) p is the fractional equilibrium ratio (4400 hrs/8760 hrs). The ratio of total annual release time (for C-14 atmospheric releases) to the total annual time during which photosynthesis occurs (taken to be 4400 hrs), under the condition that the value of p should never exceed unity. For continuous C-14 releases, p is taken to be unity.
0.11 is the fraction of total plant mass that is natural carbon (dimensionless) 0.16 is the concentration of natural carbon in the atmosphere (g/m3)
II.4-17 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-1 Critical Ranges Nearest Dairy Unrestricted Area Restricted Area Nearest Residentb Direction Farm within 5 Boundarya (m) Boundary (m) (m) milesc (m)
N 1036 1036 6300 None NNE 1378 1378 2575 None NE 2408 1609 3400 None ENE 4450 1079 5300 None E 1996 833 5200 None ESE 1465 845 2300 None SE 969 969 2700 None SSE 838 698 2900 None S 829 620 2400 None SSW 835 835 1100 None SW 628 628 1600 None WSW 533 533 2400 None W 524 524 2400 None WNW 643 643 1400 None NW 762 762 2900 None NNW 890 890 2700 None a Used in calculating the meteorological dose factors in Tables 4-3, 4-4, 4-6, and 4-7.
b The distances are rounded to the nearest conservative 100 meters.
c Used in calculating the D/Q values in Table 4-5. The distances are rounded to the nearest conservative 100 meters. A default value of 8000 meters is used when there are no dairies within 5 miles.
II.4-18 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-2 Average Wind Speeds Downwind Average Wind Speed (m/sec)a Direction Elevated Vent Ground Level N 9.7 7.7 4.9 NNE 10.1 8.0 5.1 NE 9.2 7.4 4.9 ENE 9.0 7.2 4.8 E 9.5 7.8 5.2 ESE 9.7 8.4 5.9 SE 8.1 7.4 5.9 SSE 7.4 8.7 5.0 S 6.7 5.9 4.3 SSW 5.6 3.7 2.9 SW 5.5 4.1 3.1 WSW 6.9 5.4 3.9 W 7.6 6.5 4.5 WNW 7.5 6.3 4.3 NW 7.5 6.2 3.9 NNW 8.3 6.7 4.3 a Based on LaSalle site meteorological data, January 1978 through December 1987. See Sargent & Lundy, Analysis and Technology Division, LaSalle calculation no. ATD-0164, revisions 0, 1, 2, and 3.
II.4-19 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-3 X/Q and D/Q Maxima at or Beyond the Unrestricted Area Boundary Ground Level Release Mixed Mode (Vent) Elevated (Stack)
Direction Distance X/Q D/Q Distance X/Q D/Q Distance X/Q Distance D/Q (meters) (sec/m3) (m-2) (meters) (sec/m3) (m-2) (meters) (sec/m3) (meters) (m-2)
N 1036 1.43E-06 9.09E-09 1036 4.73E-07 5.23E-09 6437 5.15E-09 1609 3.97E-10 NNE 1378 9.84E-07 6.85E-09 1378 4.01E-07 4.38E-09 5633 6.21E-09 1609 5.08E-10 NE 2408 4.43E-07 2.72E-09 2408 2.13E-07 1.81E-09 5633 6.42E-09 2408 1.74E-10 ENE 4450 1.70E-07 7.55E-10 4450 8.62E-08 4.89E-10 5633 5.38E-09 4450 1.53E-10 E 1996 5.52E-07 3.45E-09 1996 2.29E-07 2.24E-09 5633 6.60E-09 1996 1.84E-10 ESE 1465 9.07E-07 7.12E-09 1465 3.78E-07 4.92E-09 5633 8.46E-09 1609 6.75E-10 SE 969 1.05E-06 8.48E-09 969 3.80E-07 5.16E-09 5633 8.16E-09 1609 6.70E-10 SSE 838 1.16E-06 1.09E-08 838 4.68E-07 7.21E-09 6437 5.76E-09 1609 4.57E-10 S 829 1.40E-06 9.82E-09 829 3.76E-07 4.69E-09 6437 5.71E-09 1609 4.51E-10 SSW 835 1.21E-06 8.31E-09 835 3.00E-07 3.58E-09 6437 5.50E-09 1609 4.13E-10 SW 628 1.32E-06 1.32E-08 628 5.01E-07 8.29E-09 5633 6.52E-09 1609 5.47E-10 WSW 533 1.59E-06 1.70E-08 533 6.77E-07 1.13E-08 6437 6.13E-09 1609 4.80E-10 W 524 3.29E-06 2.33E-08 524 9.40E-07 1.13E-08 6437 4.32E-09 1609 2.99E-10 WNW 643 2.22E-06 1.26E-08 643 5.31E-07 5.80E-09 6437 3.41E-09 1609 2.53E-10 NW 762 1.88E-06 9.48E-09 762 4.33E-07 4.12E-09 7242 3.03E-09 1609 2.07E-10 NNW 890 1.63E-06 8.40E-09 890 4.18E-07 3.90E-09 7242 3.38E-09 1609 2.30E-10 LaSalle Site Meteorological Data 2000-2009 II.4-20 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-4
/Q and D/Q Maxima at or Beyond the Restricted Area Boundary Ground Level Release Mixed Mode (Vent) Elevated (Stack)
Direction Distance X/Q D/Q Distance X/Q D/Q Distance X/Q Distance D/Q (meters) (sec/m3) (m-2) (meters) (sec/m3) (m-2) (meters) (sec/m3) (meters) (m-2)
N 1036 1.43E-06 9.09E-09 1036 4.73E-07 5.23E-09 6437 5.15E-09 1609 3.97E-10 NNE 1378 9.84E-07 6.85E-09 1378 4.01E-07 4.38E-09 5633 6.21E-09 1609 5.08E-10 NE 1609 7.99E-07 5.44E-09 1609 3.48E-07 3.53E-09 5633 6.42E-09 1609 5.43E-10 ENE 1079 1.28E-06 8.67E-09 1079 4.49E-07 5.11E-09 5633 5.38E-09 1609 4.62E-10 E 833 2.13E-06 1.50E-08 833 6.95E-07 9.04E-09 5633 6.60E-09 1609 5.23E-10 ESE 845 2.14E-06 1.78E-08 845 7.66E-07 1.18E-08 5633 8.46E-09 1609 6.75E-10 SE 969 1.05E-06 8.48E-09 969 3.80E-07 5.16E-09 5633 8.16E-09 1609 6.70E-10 SSE 698 1.52E-06 1.46E-08 698 5.88E-07 9.45E-09 6437 5.76E-09 1609 4.57E-10 S 620 2.16E-06 1.56E-08 620 5.25E-07 6.94E-09 6437 5.71E-09 1609 4.51E-10 SSW 835 1.21E-06 8.31E-09 835 3.00E-07 3.58E-09 6437 5.50E-09 1609 4.13E-10 SW 628 1.32E-06 1.32E-08 628 5.01E-07 8.29E-09 5633 6.52E-09 1609 5.47E-10 WSW 533 1.59E-06 1.70E-08 533 6.77E-07 1.13E-08 6437 6.13E-09 1609 4.80E-10 W 524 3.29E-06 2.33E-08 524 9.40E-07 1.13E-08 6437 4.32E-09 1609 2.99E-10 WNW 643 2.22E-06 1.26E-08 643 5.31E-07 5.80E-09 6437 3.41E-09 1609 2.53E-10 NW 762 1.88E-06 9.48E-09 762 4.33E-07 4.12E-09 7242 3.03E-09 1609 2.07E-10 NNW 890 1.63E-06 8.40E-09 890 4.18E-07 3.90E-09 7242 3.38E-09 1609 2.30E-10 LaSalle Site Meteorological Data 2000-2009 II.4-21 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-5 (Page 1 of 2)
X/Q and D/Q at the Nearest Meat Animal Locations Within 5 Miles Direction Distance Ground Level Release Mixed Mode (Vent) Elevated (Stack)
X/Q D/Q X/Q D/Q X/Q D/Q miles meters (sec/m3) (m-2) (sec/m3) (m-2) (sec/m3) (m-2)
N 4.0 6400 1.11E-07 3.87E-10 5.69E-08 2.45E-10 5.15E-09 1.12E-10 NNE 1.7 2800 3.54E-07 2.03E-09 1.70E-07 1.35E-09 4.33E-09 3.44E-10 NE 3.5 5600 1.43E-07 6.19E-10 8.01E-08 4.21E-10 6.42E-09 1.75E-10 ENE 3.8 6116 1.11E-07 4.29E-10 6.01E-08 2.81E-10 5.39E-09 1.37E-10 E 5.0 8000 8.34E-08 2.99E-10 4.69E-08 2.05E-10 6.25E-09 1.07E-10 ESE 5.0 8000 8.37E-08 3.64E-10 5.10E-08 2.71E-10 7.82E-09 1.41E-10 SE 4.7 7600 5.41E-08 2.39E-10 3.66E-08 1.67E-10 7.71E-09 1.54E-10 SSE 4.7 7600 4.46E-08 2.41E-10 3.32E-08 1.93E-10 5.58E-09 1.06E-10 S 4.7 7600 5.45E-08 2.14E-10 3.86E-08 1.45E-10 5.60E-09 1.01E-10 SSW 5.0 8000 4.39E-08 1.67E-10 3.27E-08 1.10E-10 5.38E-09 8.37E-11 SW 5.0 8000 3.02E-08 1.69E-10 2.44E-08 1.37E-10 6.20E-09 1.11E-10 WSW 1.5 2400 1.69E-07 1.40E-09 1.10E-07 1.10E-09 2.75E-09 4.02E-10 W 3.0 4800 1.25E-07 5.58E-10 7.21E-08 3.33E-10 3.97E-09 1.34E-10 WNW 3.0 4800 1.15E-07 4.14E-10 5.35E-08 2.33E-10 3.17E-09 1.09E-10 NW 4.0 6400 8.73E-08 2.46E-10 4.06E-08 1.30E-10 3.02E-09 6.37E-11 NNW 4.6 7403 8.11E-08 2.15E-10 3.83E-08 1.16E-10 3.38E-09 5.50E-11 LaSalle Site Meteorological Data 2000-2009 II.4-22 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-5 (Page 2 of 2)
X/Q and D/Q at the Nearest Milk Cow Locations Within 5 Miles Direction Distance Ground Level Release Mixed Mode (Vent) Elevated (Stack)
X/Q D/Q X/Q D/Q X/Q D/Q miles meters (sec/m3) (m-2) (sec/m3) (m-2) (sec/m3) (m-2)
N 5.0 8000 8.26E-08 2.59E-10 4.43E-08 1.65E-10 4.96E-09 7.82E-11 NNE 5.0 8000 8.80E-08 3.16E-10 5.06E-08 2.15E-10 5.82E-09 9.32E-11 NE 5.0 8000 8.95E-08 3.27E-10 5.28E-08 2.24E-10 6.05E-09 1.01E-10 ENE 5.0 8000 7.76E-08 2.65E-10 4.42E-08 1.75E-10 5.12E-09 8.92E-11 E 5.0 8000 8.34E-08 2.99E-10 4.69E-08 2.05E-10 6.25E-09 1.07E-10 ESE 5.0 8000 8.37E-08 3.64E-10 5.10E-08 2.71E-10 7.82E-09 1.41E-10 SE 5.0 8000 5.03E-08 2.17E-10 3.44E-08 1.53E-10 7.56E-09 1.41E-10 SSE 5.0 8000 4.14E-08 2.20E-10 3.11E-08 1.76E-10 5.49E-09 9.73E-11 S 5.0 8000 5.06E-08 1.95E-10 3.62E-08 1.33E-10 5.52E-09 9.30E-11 SSW 5.0 8000 4.39E-08 1.67E-10 3.27E-08 1.10E-10 5.38E-09 8.37E-11 SW 5.0 8000 3.02E-08 1.69E-10 2.44E-08 1.37E-10 6.20E-09 1.11E-10 WSW 5.0 8000 2.86E-08 1.67E-10 2.33E-08 1.38E-10 5.89E-09 1.01E-10 W 5.0 8000 6.20E-08 2.24E-10 4.01E-08 1.36E-10 4.25E-09 6.30E-11 WNW 5.0 8000 5.82E-08 1.66E-10 3.07E-08 9.52E-11 3.35E-09 5.15E-11 NW 5.0 8000 6.52E-08 1.64E-10 3.20E-08 8.77E-11 2.99E-09 4.45E-11 NNW 5.0 8000 7.34E-08 1.87E-10 3.53E-08 1.01E-10 3.34E-09 4.83E-11 LaSalle Site Meteorological Data 2000-2009 II.4-23 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 1 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Kr-83m Based on Sargent & Lundy, Analysis and Technology Division, LaSalle calculation no. ATD-0164, revisions 0, 1, 2, and 3.
II.4-24 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 2 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Kr-85m II.4-25 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 3 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Kr-85 II.4-26 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 4 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Kr-87 II.4-27 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 5 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Kr-88 II.4-28 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 6 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Kr-89 II.4-29 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 7 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Kr-90 II.4-30 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 8 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Xe-131m II.4-31 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 9 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Xe-133m II.4-32 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 10 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Xe-133 II.4-33 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 11 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Xe-135m II.4-34 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 12 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Xe-135 II.4-35 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 13 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Xe-137 II.4-36 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 14 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Xe-138 II.4-37 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-6 (Page 15 of 15)
Maximum Offsite Finite Plume Gamma Dose Factors Based on 1 cm Depth at the Unrestricted Area Boundary for Ar-41 II.4-38 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-7 Deleted II.4-39 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-8 Parameters for Calculations of N-16 Skyshine Radiation From LaSalle Location Occupancy Occupancy Shielding Distance Number Activity Hours Factorc Factor Rk K OHka OFk SFk (m)
Living at home 1 (nearest 8360 0.95 0.7 1100b resident) 2 Fishing 400 0.05 1.0 2100 Living at 3 National Guard 2500 0.7 2400 Facility Mh = 5 K = 2.28 E-5 mrem / (MWe-hr)
These parameters are used to obtain an initial estimate of skyshine dose to the maximally exposed member of the public using ODCM Part II, Section 5, Equation 5-1. If desired, more realistic parameters could be used in place of these to refine the estimate. For example, one could determine whether the nearest resident really fishes the specified number of hours at the specified location.
Notes:
a The amount of time in a year that a maximally exposed fisherman would spend fishing near the site is estimates as 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> per week for 8 months per year. This yields an estimate of:
months 8
12 Hours year 52 weeks = 416 hours0.00481 days <br />0.116 hours <br />6.878307e-4 weeks <br />1.58288e-4 months <br /> Week months year year 12 year b Distance to nearest residence. (See Table 4-1) c The OFk is the quotient of the number of hours a location is occupied and the number of hours in a year. Thus, OHk
/8760 hours = OFk rounded to the nearest 0.01 digit.
In determining the maximally exposed individual, the following possibilities were considered: the nearest resident, fisherman, and persons at the National Guard facility north of the site. The annual exposre time and .location of a maximally exposed fisherman were estimated on the basis of discussion with a member of the station staff. The nearest resident was found to have the greatest exposure to skyshine. For details, see Based on Sargent & Lundy, Nuclear Safeguards and Licensing Division, LaSalle calculation no. ATD-0139, N-16 Skyshine Ground Level Doses from LaSalle Turbine Systems & Piping, Revision 0.
II.4-40 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-9 (page 1 of 2)
Elevated Level Joint Frequency Distribution Table Summary 375 Foot Elevation Data NOTE: Wind direction in tables are presented in wind from and not wind to direction.
II.4-41 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-9 (page 2 of 2)
Elevated Level Joint Frequency Distribution Table Summary 375 Foot Elevation Data II.4-42 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-10 (Page 1 of 2)
Mid Elevation Joint Frequency Distribution Table Summaries 200 Foot Elevation Data NOTE: Wind direction in tables are presented in wind from and not wind to direction.
II.4-43 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-10 (Page 2 of 2)
Mid Elevation Joint Frequency Distribution Table Summaries 200 Foot Elevation Data II.4-44 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-11 (Page 1 of 2)
Ground Level Joint Frequency Distribution Table Summary 33 Foot Elevation Data NOTE: Wind direction in tables are presented in wind from and not wind to direction.
II.4-45 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-11 (Page 2 of 2)
Ground Level Joint Frequency Distribution Table Summary 33 Foot Elevation Data II.4-46 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-12 Station Characteristics STATION: LaSalle LOCATION: Six miles South of Marseilles, Illinois - LaSalle County CHARATERISTICS OF ELEVATED RELEASE POINT
- 1) Release Height = 112.8 ma 2) Diameter = 5.64 m
- 3) Exit Speed = 14.7 m/sa 4) Heat Content = 0 Kcal/sa CHARATERISTICS OF VENT STACK RELEASE POINT: NOT APPLICABLE
- 1) Release Height = ______ma 2) Diameter = ______m
- 3) Exit Speed = ______m/sa CHARATERISTICS OF GROUND LEVEL RELEASE
- 1) Release Height = 0 m
- 2) Building Factor (D) = 56.4 ma METEOROLOGICAL DATA A 400 foot tower is located 725 meters Southeast of elevated release point.
Release Point Wind Speed & Direction Differential Temperature Elevated 375 ft 375 - 33 ft Vent (N/A) (N/A)
Ground 33 ft 200 - 33 ft a Used in calculating the meteorological and dose factors in Tables 4-3, and 4-5 through 4-7.
II.4-47 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4 - 13 Dose Factors for Noble Gases Beta Air Beta Skin Gamma Air Gamma Total Dose Factor Dose Factor Dose Factor Body Dose Factor Ni Li Mi Ki Nuclide (mrad/yr per (mrem/yr per (mrad/yr per (mrem/yr per uCi/m3) uCi/m3) uCi/m3) uCi/m3)
Kr-83m 2.88E+02 --- 1.93E+01 7.56E-02 Kr-85m 1.97E+03 1.46E+03 1.23E+03 1.17E+03 Kr-85 1.95E+03 1.34E+03 1.72E+01 1.61E+01 Kr-87 1.03E+04 9.73E+03 6.17E+03 5.92E+03 Kr-88 2.93E+03 2.37E+03 1.52E+04 1.47E+04 Kr-89 1.06E+04 1.01E+04 1.73E+04 1.66E+04 Kr-90 7.83E+03 7.29E+03 1.63E+04 1.56E+04 Xe- 1.11E+03 4.76E+02 1.56E+02 9.15E+01 131m Xe- 1.48E+03 9.94E+02 3.27E+02 2.51E+02 133m Xe-133 1.05E+03 3.06E+02 3.53E+02 2.94E+02 Xe- 7.39E+02 7.11E+02 3.36E+03 3.12E+03 135m Xe-135 2.46E+03 1.86E+03 1.92E+03 1.81E+03 Xe-137 1.27E+04 1.22E+04 1.51E+03 1.42E+03 Xe-138 4.75E+03 4.13E+03 9.21E+03 8.83E+03 Ar-41 3.28E+03 2.69E+03 9.30E+03 8.84E+03 Source: Table B-1 of Reference 6.
II.4-48 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4 - 14 (Page 1 of 3)
External Dose Factors for Standing on Contaminated Ground DFGij (mrem/hr per pCi/ m2)
Whole Body Element Dose Factor Reference Element Dose Factor Reference H-3 0.00E+00 6 Be-7 5.95E-10 99 C-14 0.00E+00 6 F-18 1.19E-08 99 Na-22 2.42E-08 99 Na-24 2.50E-08 6 Mg-27 1.14E-08 99 Mg-28 1.48E-08 99 Al-26 2.95E-08 99 Al-28 2.00E-08 99 P-32 0.00E+00 6 Cl-38 1.70E-08 99 Ar-41 1.39E-08 99 K-40 2.22E-09 99 K-42 4.64E-09 99 K-43 1.19E-08 99 Ca-47 1.14E-08 99 Sc-44 2.50E-08 99 Sc-46m 1.21E-09 99 Sc-46 2.24E-08 99 Sc-47 1.46E-09 99 Ti-44 1.95E-09 99 V-48 3.21E-08 99 Cr-51 2.20E-10 6 Mn-52m 2.79E-08 99 Mn-52 3.80E-08 99 Mn-54 5.80E-09 6 Mn-56 1.10E-08 6 Fe-52 9.12E-09 99 Fe-55 0.00E+00 6 Fe-59 8.00E-09 6 Co-57 1.65E-09 99 Co-58 7.00E-09 6 Co-60 1.70E-08 6 Ni-63 0.00E+00 6 Ni-65 3.70E-09 6 Cu-64 1.50E-09 6 Cu-67 1.52E-09 99 Cu-68 8.60E-091 -- Zn-65 4.00E-09 6 Zn-69m 5.06E-09 99 Zn-69 0.00E+00 6 Ga-66 2.70E-08 99 Ga-67 1.89E-09 99 Ga-68 1.24E-08 99 Ga-72 3.00E-08 99 Ge-77 1.34E-08 99 As-72 2.23E-08 99 As-73 1.16E-10 99 As-74 9.41E-09 99 As-76 6.46E-09 99 As-77 1.79E-10 99 Se-73 1.38E-08 99 Se-75 4.98E-09 99 Br-77 3.84E-09 99 Br-80 2.01E-09 99 Br-82 3.00E-08 99 Br-83 6.40E-11 6 Br-84 1.20E-08 6 Br-85 0.00E+00 6 Kr-79 3.07E-09 99 Kr-81 1.59E-10 99 Kr-83m 1.42E-11 99 Kr-85m 2.24E-09 99 Kr-85 1.35E-10 99 Kr-87 1.03E-08 99 Kr-88 2.07E-08 99 Kr-90 1.56E-08 99 Rb-84 1.07E-08 99 Rb-86 6.30E-10 6 Rb-87 0.00E+00 99 Rb-88 3.50E-09 6 Rb-89 1.50E-08 6 Sr-85 6.16E-09 99 Sr-87m 3.92E-09 99 Sr-89 5.60E-13 6 Sr-90 1.84E-11 99 Sr-91 7.10E-09 6 Sr-92 9.00E-09 6 Y-86 4.00E-08 99 Y-87 5.53E-09 99 Y-88 2.88E-08 99 Y-90 2.20E-12 6 Y-91m 3.80E-09 6 Y-91 2.40E-11 6 Y-92 1.60E-09 6 Y-93 5.70E-10 6 Zr-95 5.00E-09 6 Zr-97 5.50E-09 6 Nb-94 1.84E-08 99 Nb-95 5.10E-09 6 Nb-97m 8.57E-09 99 Nb-97 8.48E-09 99 Mo-99 1.90E-09 6 Tc-99m 9.60E-10 6 Tc-101 2.70E-09 6 Tc-104 1.83E-081 -- Ru-97 2.99E-09 99 Ru-103 3.60E-09 6 Ru-105 4.50E-09 6 Ru/Rh-106 5.76E-093 6, 99 Pc-109 3.80E-10 99 Cc-109 1.12E-10 99 In-111 5.11E-09 99 In-115m 2.01E-09 99 In-116 0.00E+002 --
Sn-113 1.15E-09 99 Sn-117m 1.96E-08 99 Sn-119m 7.05E-11 99 Sb-117 0.00E+002 --
Sb-122 2.71E-091 -- Sb-124 1.16E-081 --
Sb-125 4.56E-09 99 Sb-126 7.13E-10 99 Ag-108m 1.92E-08 99 Ag-108 1.14E-09 99 Ag-110m 1.80E-08 6 Ag-111 6.75E-10 99 Te-121m 2.65E-09 99 Te-121 6.75E-09 99 II.4-49 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4 - 14 (Page 2 of 3)
External Dose Factors for Standing on Contaminated Ground DFGij (mrem/hr per pCi/ m2)
Whole Body Element Dose Factor Reference Element Dose Factor Reference Te-123m 1.88E-09 99 Te-125m 3.50E-11 6 Te-125 0.00E+002 -- Te-127m 1.10E-12 6 Te-127 1.00E-11 6 Te-129m 7.70E-10 6 Te-129 7.10E-10 6 Te-131m 8.40E-09 6 Te-131 2.20E-09 6 Te-I-132 3.40E-095 6 Te-134 1.05E-08 99 I-123 2.12E-09 99 I-124 1.23E-08 99 I-125 2.89E-10 99 I-130 1.40E-08 6 I-131 2.80E-09 6 I-133 3.70E-09 6 I-134 1.60E-08 6 I-135 1.20E-08 6 Xe-127 3.44E-09 99 Xe-129m 5.57E-10 99 Xe-131m 2.13E-10 99 Xe-133m 4.81E-10 99 Xe-133 5.91E-10 99 Xe-135m 5.23E-09 99 Xe-135 3.36E-09 99 Xe-137 4.26E-09 99 Xe-138 1.30E-08 99 Cs-129 3.39E-09 99 Cs-132 8.40E-09 99 Cs-134 1.20E-08 6 Cs-136 1.50E-08 6 Cs-137/Ba-137m 1.14E-084 6, 99 Cs-138 2.10E-08 6 Cs-139 5.15E-09 99 Ba-131 5.74E-09 99 Ba-133m 8.10E-10 99 Ba-133 4.85E-09 99 Ba-135m 7.26E-10 99 Ba-137m 7.17E-09 99 Ba-137 0.00E+002 -- Ba-139 2.40E-09 6 Ba-La-140 1.71E-086 6 Ba-141 4.30E-09 6 Ba-142 7.90E-09 6 La-142 1.50E-08 6 Ce-139 2.04E-09 99 Ce-141 5.50E-10 6 Ce-143 2.20E-09 6 Ce-Pr-144 5.20E-107 6 Pr-142 1.84E-09 99 Pr-143 0.00E+00 6 Nc-147 1.00E-09 6 Nc-149 5.32E-09 99 Pm-145 3.38E-10 99 Pm-148m 2.35E-08 99 Pm-148 7.22E-09 99 Pm-149 5.32E-10 99 Sm-153 8.95E-10 99 Eu-152 1.30E-08 99 Eu-154 1.41E-08 99 Eu-155 8.27E-10 99 Gc-153 1.46E-09 99 Dy-157 4.39E-09 99 Er-169 6.12E-14 99 Er-171 5.11E-09 99 Tm-170 3.41E-10 99 Yb-169 4.12E-09 99 Yb-175 4.94E-10 99 Lu-177 4.60E-10 99 Hf-181 6.67E-09 99 Ta-182 1.42E-08 99 Ta-183 2.93E-091 -- W-187 3.10E-09 6 Re-188 1.89E-09 99 Os-191 9.83E-10 99 Ir-194 2.31E-09 99 Pt-195m 9.79E-10 99 Pt-197 3.57E-10 99 Au-195m 2.54E-09 99 Au-195 1.14E-09 99 Au-198 5.19E-09 99 Au-199 1.18E-09 99 Hg-197 9.33E-10 99 Hg-203 2.89E-09 99 Tl-201 1.24E-09 99 Tl-206 0.00E+002 -- Tl-208 3.58E-08 99 Pb-203 3.88E-09 99 Pb-210 3.57E-11 99 Pb-212 1.91E-09 99 Pb-214 3.18E-09 99 Bi-206 3.74E-08 99 Bi-207 1.77E-08 99 Bi-214 1.71E-08 99 Ra-226 8.78E-11 99 Th-232 8.14E-12 99 U-238 7.98E-12 99 Np-239 9.50E-10 6 Am-241 3.48E-10 99 1 Valued derived by comparing the percentage and MeV of the nuclide's gammas and then comparing to Cesium-137, as a value was not available in the literature.
2 0.0 due to low yield and short half-life. A value was not available in the literature.
II.4-50 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4 - 14 (Page 3 of 3)
External Dose Factors for Standing on Contaminated Ground DFGij (mrem/hr per pCi/ m2) 3 Value is the sum of Ru-106 (1.50E-9) and Rh-106 (4.26E-9). The Rh-106 value is from Reference 99 and the Ru-106 value is from Reference 6.
4 Value is the sum of Cs-137 (4.20E-9) and Ba-137m (7.17E-9). The values are from references 6 and 99, respectively.
5 Value is the sum of Te-132 (1.70E-9) and I-132 (1.70E-9).
6 Value is the sum of Ba-140 (2.10E-9) and La-140 (1.50E-8) from reference 6. In Reference 6, see Table E-6.
7 Value is the sum of Ce-144 (3.20E-10) and Pr-144 (2.00E-10) from reference 6.
Note: Dose assessments for 10CFR20 and 40CFR190 compliance are made for an adult only.
Dose assessments for 10CFR50 Appendix are made using dose factors of Regulatory Guide 1.109 (Reference 6) for all age groups.
II.4-51 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 1 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Kr-83m Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 1.93E-10 1.43E-08 1.43E-08 NNE 1378 2.73E-10 4.24E-08 4.24E-08 NE 2408 3.21E-10 9.37E-08 9.37E-08 ENE 4450 2.73E-10 1.25E-07 1.25E-07 E 1996 2.54E-10 5.39E-08 5.39E-08 ESE 1465 2.64E-10 2.83E-08 2.83E-08 SE 969 2.32E-10 8.97E-09 8.97E-09 SSE 838 1.62E-10 6.53E-09 6.53E-09 S 829 1.70E-10 1.37E-08 1.37E-08 SSW 835 1.51E-10 8.61E-09 8.61E-09 SW 628 2.16E-10 4.62E-09 4.62E-09 WSW 533 2.05E-10 5.53E-10 5.53E-10 W 524 1.70E-10 4.24E-10 4.24E-10 WNW 643 1.23E-10 1.11E-09 1.11E-09 NW 762 1.06E-10 1.41E-09 1.41E-09 NNW 890 1.27E-10 2.89E-09 2.89E-09 II.4-52 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 2 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Kr-85m Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 2.60E-05 3.86E-05 3.86E-05 NNE 1378 2.51E-05 3.72E-05 3.72E-05 NE 2408 1.69E-05 2.51E-05 2.51E-05 ENE 4450 8.36E-06 1.24E-05 1.24E-05 E 1996 1.69E-05 2.50E-05 2.50E-05 ESE 1465 2.40E-05 3.56E-05 3.56E-05 SE 969 3.18E-05 4.72E-05 4.72E-05 SSE 838 2.60E-05 3.86E-05 3.86E-05 S 829 2.66E-05 3.96E-05 3.96E-05 SSW 835 2.54E-05 3.78E-05 3.78E-05 SW 628 3.90E-05 5.79E-05 5.79E-05 WSW 533 4.13E-05 6.13E-05 6.13E-05 W 524 3.52E-05 5.23E-05 5.23E-05 WNW 643 2.37E-05 3.52E-05 3.52E-05 NW 762 1.96E-05 2.91E-05 2.91E-05 NNW 890 2.12E-05 3.15E-05 3.15E-05 II.4-53 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 3 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Kr-85 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 4.71E-07 7.14E-07 7.14E-07 NNE 1378 4.35E-07 6.59E-07 6.59E-07 NE 2408 2.79E-07 4.23E-07 4.23E-07 ENE 4450 1.30E-07 1.97E-07 1.97E-07 E 1996 2.87E-07 4.35E-07 4.35E-07 ESE 1465 4.16E-07 6.31E-07 6.31E-07 SE 969 5.76E-07 8.72E-07 8.72E-07 SSE 838 4.85E-07 7.35E-07 7.35E-07 S 829 5.04E-07 7.64E-07 7.64E-07 SSW 835 4.83E-07 7.32E-07 7.32E-07 SW 628 7.33E-07 1.11E-06 1.11E-06 WSW 533 7.82E-07 1.19E-06 1.19E-06 W 524 6.68E-07 1.01E-06 1.01E-06 WNW 643 4.47E-07 6.77E-07 6.77E-07 NW 762 3.68E-07 5.58E-07 5.58E-07 NNW 890 3.94E-07 5.96E-07 5.96E-07 II.4-54 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 4 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Kr-87 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 1.56E-04 2.35E-04 2.35E-04 NNE 1378 1.42E-04 2.13E-04 2.13E-04 NE 2408 8.74E-05 1.31E-04 1.31E-04 ENE 4450 3.76E-05 5.66E-05 5.66E-05 E 1996 9.12E-05 1.37E-04 1.37E-04 ESE 1465 1.35E-04 2.04E-04 2.04E-04 SE 969 1.92E-04 2.88E-04 2.88E-04 SSE 838 1.63E-04 2.45E-04 2.45E-04 S 829 1.70E-04 2.55E-04 2.55E-04 SSW 835 1.62E-04 2.44E-04 2.44E-04 SW 628 2.48E-04 3.73E-04 3.73E-04 WSW 533 2.66E-04 4.01E-04 4.01E-04 W 524 2.27E-04 3.41E-04 3.41E-04 WNW 643 1.51E-04 2.27E-04 2.27E-04 NW 762 1.24E-04 1.86E-04 1.86E-04 NNW 890 1.32E-04 1.98E-04 1.98E-04 II.4-55 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 5 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Kr-88 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 4.07E-04 6.11E-04 6.11E-04 NNE 1378 3.70E-04 5.56E-04 5.56E-04 NE 2408 2.38E-04 3.57E-04 3.57E-04 ENE 4450 1.11E-04 1.67E-04 1.67E-04 E 1996 2.47E-04 3.71E-04 3.71E-04 ESE 1465 3.56E-04 5.35E-04 5.35E-04 SE 969 4.95E-04 7.44E-04 7.44E-04 SSE 838 4.23E-04 6.35E-04 6.35E-04 S 829 4.44E-04 6.67E-04 6.67E-04 SSW 835 4.26E-04 6.40E-04 6.40E-04 SW 628 6.36E-04 9.54E-04 9.54E-04 WSW 533 6.80E-04 1.02E-03 1.02E-03 W 524 5.81E-04 8.72E-04 8.72E-04 WNW 643 3.89E-04 5.84E-04 5.84E-04 NW 762 3.21E-04 4.82E-04 4.82E-04 NNW 890 3.42E-04 5.14E-04 5.14E-04 II.4-56 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 6 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Kr-89 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 2.85E-04 4.28E-04 4.28E-04 NNE 1378 2.47E-04 3.71E-04 3.71E-04 NE 2408 1.13E-04 1.70E-04 1.70E-04 ENE 4450 2.89E-05 4.35E-05 4.35E-05 E 1996 1.23E-04 1.85E-04 1.85E-04 ESE 1465 2.23E-04 3.34E-04 3.34E-04 SE 969 3.62E-04 5.45E-04 5.45E-04 SSE 838 3.08E-04 4.63E-04 4.63E-04 S 829 3.11E-04 4.67E-04 4.67E-04 SSW 835 2.92E-04 4.39E-04 4.39E-04 SW 628 5.16E-04 7.75E-04 7.75E-04 WSW 533 5.77E-04 8.68E-04 8.68E-04 W 524 4.85E-04 7.29E-04 7.29E-04 WNW 643 3.04E-04 4.57E-04 4.57E-04 NW 762 2.37E-04 3.55E-04 3.55E-04 NNW 890 2.46E-04 3.70E-04 3.70E-04 II.4-57 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 7 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-131m Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 5.60E-06 8.50E-06 8.50E-06 NNE 1378 5.55E-06 8.53E-06 8.53E-06 NE 2408 3.99E-06 6.29E-06 6.29E-06 ENE 4450 2.18E-06 3.58E-06 3.58E-06 E 1996 3.86E-06 6.02E-06 6.02E-06 ESE 1465 5.32E-06 8.18E-06 8.18E-06 SE 969 6.83E-06 1.04E-05 1.04E-05 SSE 838 5.53E-06 8.36E-06 8.36E-06 S 829 5.67E-06 8.57E-06 8.57E-06 SSW 835 5.39E-06 8.15E-06 8.15E-06 SW 628 8.24E-06 1.24E-05 1.24E-05 WSW 533 8.66E-06 1.30E-05 1.30E-05 W 524 7.39E-06 1.11E-05 1.11E-05 WNW 643 5.00E-06 7.53E-06 7.53E-06 NW 762 4.14E-06 6.25E-06 6.25E-06 NNW 890 4.51E-06 6.82E-06 6.82E-06 II.4-58 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 8 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-133m Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 4.54E-06 7.05E-06 7.05E-06 NNE 1378 4.43E-06 6.98E-06 6.98E-06 NE 2408 3.13E-06 5.11E-06 5.11E-06 ENE 4450 1.70E-06 2.91E-06 2.91E-06 E 1996 3.06E-06 4.91E-06 4.91E-06 ESE 1465 4.24E-06 6.69E-06 6.69E-06 SE 969 5.54E-06 8.60E-06 8.60E-06 SSE 838 4.54E-06 7.01E-06 7.01E-06 S 829 4.68E-06 7.23E-06 7.23E-06 SSW 835 4.46E-06 6.88E-06 6.88E-06 SW 628 6.79E-06 1.05E-05 1.05E-05 WSW 533 7.17E-06 1.10E-05 1.10E-05 W 524 6.12E-06 9.39E-06 9.39E-06 WNW 643 4.12E-06 6.34E-06 6.34E-06 NW 762 3.41E-06 5.25E-06 5.25E-06 NNW 890 3.69E-06 5.70E-06 5.70E-06 II.4-59 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 9 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-133 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 3.86E-06 5.83E-06 5.83E-06 NNE 1378 3.98E-06 6.08E-06 6.08E-06 NE 2408 3.02E-06 4.74E-06 4.74E-06 ENE 4450 1.76E-06 2.86E-06 2.86E-06 E 1996 2.85E-06 4.42E-06 4.42E-06 ESE 1465 3.82E-06 5.85E-06 5.85E-06 SE 969 4.71E-06 7.11E-06 7.11E-06 SSE 838 3.73E-06 5.61E-06 5.61E-06 S 829 3.79E-06 5.71E-06 5.71E-06 SSW 835 3.59E-06 5.40E-06 5.40E-06 SW 628 5.50E-06 8.25E-06 8.25E-06 WSW 533 5.72E-06 8.56E-06 8.56E-06 W 524 4.88E-06 7.30E-06 7.30E-06 WNW 643 3.32E-06 4.97E-06 4.97E-06 NW 762 2.77E-06 4.15E-06 4.15E-06 NNW 890 3.04E-06 4.58E-06 4.58E-06 II.4-60 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 10 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-135m Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 7.99E-05 1.21E-04 1.21E-04 NNE 1378 7.23E-05 1.10E-04 1.10E-04 NE 2408 4.11E-05 6.23E-05 6.23E-05 ENE 4450 1.46E-05 2.21E-05 2.21E-05 E 1996 4.32E-05 6.55E-05 6.55E-05 ESE 1465 6.81E-05 1.03E-04 1.03E-04 SE 969 9.95E-05 1.51E-04 1.51E-04 SSE 838 8.38E-05 1.27E-04 1.27E-04 S 829 8.60E-05 1.30E-04 1.30E-04 SSW 835 8.18E-05 1.24E-04 1.24E-04 SW 628 1.31E-04 1.98E-04 1.98E-04 WSW 533 1.42E-04 2.15E-04 2.15E-04 W 524 1.20E-04 1.82E-04 1.82E-04 WNW 643 7.87E-05 1.19E-04 1.19E-04 NW 762 6.36E-05 9.64E-05 9.64E-05 NNW 890 6.76E-05 1.02E-04 1.02E-04 II.4-61 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 11 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-135 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 4.50E-05 6.76E-05 6.76E-05 NNE 1378 4.26E-05 6.40E-05 6.40E-05 NE 2408 2.82E-05 4.24E-05 4.24E-05 ENE 4450 1.36E-05 2.05E-05 2.05E-05 E 1996 2.84E-05 4.27E-05 4.27E-05 ESE 1465 4.08E-05 6.12E-05 6.12E-05 SE 969 5.50E-05 8.26E-05 8.26E-05 SSE 838 4.55E-05 6.84E-05 6.84E-05 S 829 4.69E-05 7.05E-05 7.05E-05 SSW 835 4.48E-05 6.74E-05 6.74E-05 SW 628 6.85E-05 1.03E-04 1.03E-04 WSW 533 7.27E-05 1.09E-04 1.09E-04 W 524 6.22E-05 9.34E-05 9.34E-05 WNW 643 4.17E-05 6.26E-05 6.26E-05 NW 762 3.44E-05 5.17E-05 5.17E-05 NNW 890 3.71E-05 5.57E-05 5.57E-05 II.4-62 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 12 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-137 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 2.34E-05 3.53E-05 3.53E-05 NNE 1378 2.04E-05 3.08E-05 3.08E-05 NE 2408 8.68E-06 1.31E-05 1.31E-05 ENE 4450 1.69E-06 2.55E-06 2.55E-06 E 1996 9.48E-06 1.43E-05 1.43E-05 ESE 1465 1.80E-05 2.73E-05 2.73E-05 SE 969 2.99E-05 4.53E-05 4.53E-05 SSE 838 2.51E-05 3.80E-05 3.80E-05 S 829 2.51E-05 3.79E-05 3.79E-05 SSW 835 2.34E-05 3.53E-05 3.53E-05 SW 628 4.28E-05 6.47E-05 6.47E-05 WSW 533 4.81E-05 7.27E-05 7.27E-05 W 524 4.03E-05 6.09E-05 6.09E-05 WNW 643 2.51E-05 3.79E-05 3.79E-05 NW 762 1.93E-05 2.92E-05 2.92E-05 NNW 890 2.01E-05 3.04E-05 3.04E-05 II.4-63 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 13 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-138 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 2.47E-04 3.71E-04 3.71E-04 NNE 1378 2.24E-04 3.37E-04 3.37E-04 NE 2408 1.38E-04 2.07E-04 2.07E-04 ENE 4450 5.80E-05 8.72E-05 8.72E-05 E 1996 1.44E-04 2.17E-04 2.17E-04 ESE 1465 2.15E-04 3.22E-04 3.22E-04 SE 969 3.04E-04 4.56E-04 4.56E-04 SSE 838 2.58E-04 3.87E-04 3.87E-04 S 829 2.69E-04 4.03E-04 4.03E-04 SSW 835 2.57E-04 3.86E-04 3.86E-04 SW 628 3.92E-04 5.89E-04 5.89E-04 WSW 533 4.21E-04 6.32E-04 6.32E-04 W 524 3.59E-04 5.39E-04 5.39E-04 WNW 643 2.39E-04 3.58E-04 3.58E-04 NW 762 1.96E-04 2.94E-04 2.94E-04 NNW 890 2.09E-04 3.13E-04 3.13E-04 II.4-64 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 14 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Xe-139 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 1.23E-05 1.84E-05 1.84E-05 NNE 1378 8.83E-06 1.33E-05 1.33E-05 NE 2408 2.03E-06 3.04E-06 3.04E-06 ENE 4450 3.82E-07 5.73E-07 5.73E-07 E 1996 2.51E-06 3.77E-06 3.77E-06 ESE 1465 6.50E-06 9.77E-06 9.77E-06 SE 969 1.51E-05 2.27E-05 2.27E-05 SSE 838 1.30E-05 1.95E-05 1.95E-05 S 829 1.20E-05 1.80E-05 1.80E-05 SSW 835 1.00E-05 1.50E-05 1.50E-05 SW 628 2.90E-05 4.36E-05 4.36E-05 WSW 533 3.67E-05 5.51E-05 5.51E-05 W 524 3.07E-05 4.61E-05 4.61E-05 WNW 643 1.67E-05 2.51E-05 2.51E-05 NW 762 1.12E-05 1.69E-05 1.69E-05 NNW 890 1.06E-05 1.59E-05 1.59E-05 II.4-65 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-15 (page 15 of 15)
Maximum Bi and Vi at or Beyond the Unrestricted Area Boundary for Ar-41 Total Body Gamma Air Annual Annual 500 hour0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> Direction Distance Vi Bi bi (meters) (mrem*sec) (mrad*sec) (mrad*sec)
(yr*µCi) (yr*µCi) (yr*µCi)
N 1036 3.05E-04 4.57E-04 4.57E-04 NNE 1378 2.75E-04 4.13E-04 4.13E-04 NE 2408 1.70E-04 2.55E-04 2.55E-04 ENE 4450 7.37E-05 1.11E-04 1.11E-04 E 1996 1.78E-04 2.67E-04 2.67E-04 ESE 1465 2.63E-04 3.95E-04 3.95E-04 SE 969 3.74E-04 5.61E-04 5.61E-04 SSE 838 3.19E-04 4.79E-04 4.79E-04 S 829 3.34E-04 5.01E-04 5.01E-04 SSW 835 3.20E-04 4.80E-04 4.80E-04 SW 628 4.85E-04 7.28E-04 7.28E-04 WSW 533 5.22E-04 7.83E-04 7.83E-04 W 524 4.44E-04 6.67E-04 6.67E-04 WNW 643 2.96E-04 4.44E-04 4.44E-04 NW 762 2.43E-04 3.64E-04 3.64E-04 NNW 890 2.58E-04 3.87E-04 3.87E-04 II.4-66 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-16 (Page 1 of 4)
Infant Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 6.63E+00 6.63E+00 6.63E+00 6.63E+00 6.63E+00 6.63E+00 0.00E+00 C-14 8.93E+02 1.91E+02 1.91E+02 1.91E+02 1.91E+02 1.91E+02 1.91E+02 0.00E+00 NA-22 3.70E+03 3.70E+03 3.70E+03 3.70E+03 3.70E+03 3.70E+03 3.70E+03 0.00E+00 NA-24 2.19E+02 2.19E+02 2.19E+02 2.19E+02 2.19E+02 2.19E+02 2.19E+02 0.00E+00 P-32 6.25E+04 3.68E+03 2.42E+03 0.00E+00 0.00E+00 0.00E+00 8.46E+02 0.00E+00 CA-41 1.41E+04 0.00E+00 1.54E+03 0.00E+00 0.00E+00 0.00E+00 7.20E+00 0.00E+00 SC-46 1.41E+00 2.03E+00 6.34E-01 0.00E+00 1.34E+00 0.00E+00 1.32E+03 0.00E+00 CR-51 0.00E+00 0.00E+00 5.25E-01 3.42E-01 7.48E-02 6.66E-01 1.53E+01 0.00E+00 MN-54 0.00E+00 7.49E+02 1.70E+02 0.00E+00 1.66E+02 0.00E+00 2.75E+02 0.00E+00 FE-55 5.23E+02 3.38E+02 9.04E+01 0.00E+00 0.00E+00 1.65E+02 4.29E+01 0.00E+00 MN-56 0.00E+00 1.22E+00 2.11E-01 0.00E+00 1.05E+00 0.00E+00 1.11E+02 0.00E+00 CO-57 0.00E+00 4.33E+01 7.04E+01 0.00E+00 0.00E+00 0.00E+00 1.47E+02 0.00E+00 CO-58 0.00E+00 1.35E+02 3.37E+02 0.00E+00 0.00E+00 0.00E+00 3.36E+02 0.00E+00 FE-59 1.15E+03 2.01E+03 7.92E+02 0.00E+00 0.00E+00 5.94E+02 9.61E+02 0.00E+00 CO-60 0.00E+00 4.07E+02 9.60E+02 0.00E+00 0.00E+00 0.00E+00 9.68E+02 0.00E+00 NI-59 1.78E+03 5.46E+02 3.08E+02 0.00E+00 0.00E+00 0.00E+00 2.70E+01 0.00E+00 NI-63 2.39E+04 1.48E+03 8.29E+02 0.00E+00 0.00E+00 0.00E+00 7.35E+01 0.00E+00 CU-64 0.00E+00 1.19E+01 5.52E+00 0.00E+00 2.02E+01 0.00E+00 2.45E+02 0.00E+00 NI-65 6.53E+00 7.39E-01 3.36E-01 0.00E+00 0.00E+00 0.00E+00 5.62E+01 0.00E+00 ZN-65 6.92E+02 2.37E+03 1.09E+03 0.00E+00 1.15E+03 0.00E+00 2.01E+03 0.00E+00 ZN-69m 3.09E+01 6.30E+01 5.74E+00 0.00E+00 2.55E+01 0.00E+00 8.73E+02 0.00E+00 ZN-69 4.44E-04 8.00E-04 5.95E-05 0.00E+00 3.32E-04 0.00E+00 6.52E-02 0.00E+00 SE-79 0.00E+00 7.91E+02 1.47E+02 0.00E+00 9.15E+02 0.00E+00 2.10E+01 0.00E+00 BR-82 0.00E+00 0.00E+00 3.78E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 4.21E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 2.20E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.80E-76 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 6.29E+03 3.11E+03 0.00E+00 0.00E+00 0.00E+00 1.61E+02 0.00E+00 RB-87 0.00E+00 3.35E+03 1.33E+03 0.00E+00 0.00E+00 0.00E+00 2.25E+01 0.00E+00 RB-88 0.00E+00 1.25E-11 6.85E-12 0.00E+00 0.00E+00 0.00E+00 1.22E-11 0.00E+00 RB-89 0.00E+00 9.88E-14 6.80E-14 0.00E+00 0.00E+00 0.00E+00 3.36E-14 0.00E+00 SR-89 9.39E+04 0.00E+00 2.69E+03 0.00E+00 0.00E+00 0.00E+00 1.93E+03 0.00E+00 SR-90 1.07E+06 0.00E+00 2.16E+04 0.00E+00 0.00E+00 0.00E+00 8.70E+03 0.00E+00 Y-90 2.88E+00 0.00E+00 7.71E-02 0.00E+00 0.00E+00 0.00E+00 3.97E+03 0.00E+00 SR-91 7.85E+02 0.00E+00 2.84E+01 0.00E+00 0.00E+00 0.00E+00 9.29E+02 0.00E+00 Y-91m 1.33E-06 0.00E+00 4.54E-08 0.00E+00 0.00E+00 0.00E+00 4.44E-03 0.00E+00 Y-91 4.23E+01 0.00E+00 1.13E+00 0.00E+00 0.00E+00 0.00E+00 3.03E+03 0.00E+00 II.4-67 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-16 (Page 2 of 4)
Infant Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 3.36E+01 0.00E+00 1.25E+00 0.00E+00 0.00E+00 0.00E+00 3.62E+02 0.00E+00 Y-92 2.75E-02 0.00E+00 7.73E-04 0.00E+00 0.00E+00 0.00E+00 5.25E+02 0.00E+00 Y-93 4.02E-01 0.00E+00 1.09E-02 0.00E+00 0.00E+00 0.00E+00 3.17E+03 0.00E+00 NB-93m 4.63E+00 1.25E+00 3.92E-01 0.00E+00 1.22E+00 0.00E+00 1.50E+02 0.00E+00 NB-95 1.57E+00 6.45E-01 3.73E-01 0.00E+00 4.63E-01 0.00E+00 5.45E+02 0.00E+00 NB-97 1.70E-05 3.64E-06 1.31E-06 0.00E+00 2.84E-06 0.00E+00 1.15E+00 0.00E+00 ZR-93 7.27E+00 3.46E+00 2.09E+00 0.00E+00 1.02E+01 0.00E+00 9.00E+02 0.00E+00 ZR-95 7.72E+00 1.88E+00 1.33E+00 0.00E+00 2.03E+00 0.00E+00 9.37E+02 0.00E+00 ZR-97 3.41E-01 5.85E-02 2.67E-02 0.00E+00 5.90E-02 0.00E+00 3.73E+03 0.00E+00 MO-93 0.00E+00 2.13E+03 6.86E+01 0.00E+00 4.26E+02 0.00E+00 4.56E+01 0.00E+00 MO-99 0.00E+00 1.13E+03 2.20E+02 0.00E+00 1.69E+03 0.00E+00 3.72E+02 0.00E+00 TC-99 4.07E+01 5.50E+01 1.71E+01 0.00E+00 4.63E+02 5.35E+00 2.38E+02 0.00E+00 TC-99m 1.82E-02 3.75E-02 4.83E-01 0.00E+00 4.03E-01 1.96E-02 1.09E+01 0.00E+00 TC-101 4.66E-17 5.87E-17 5.81E-16 0.00E+00 6.98E-16 3.20E-17 9.98E-15 0.00E+00 RU-103 5.53E+01 0.00E+00 1.85E+01 0.00E+00 1.15E+02 0.00E+00 6.72E+02 0.00E+00 RU-105 7.87E-01 0.00E+00 2.65E-01 0.00E+00 5.79E+00 0.00E+00 3.13E+02 0.00E+00 RU-106 9.07E+02 0.00E+00 1.13E+02 0.00E+00 1.07E+03 0.00E+00 6.89E+03 0.00E+00 RH-105 3.25E+01 2.12E+01 1.43E+01 0.00E+00 5.90E+01 0.00E+00 5.27E+02 0.00E+00 PD-107 0.00E+00 4.48E+01 3.18E+00 0.00E+00 2.56E+02 0.00E+00 3.56E+01 0.00E+00 PD-109 0.00E+00 3.04E+01 7.35E+00 0.00E+00 1.12E+02 0.00E+00 7.47E+02 0.00E+00 AG-110m 3.75E+01 2.73E+01 1.81E+01 0.00E+00 3.91E+01 0.00E+00 1.42E+03 0.00E+00 AG-111 1.87E+01 7.26E+00 3.85E+00 0.00E+00 1.52E+01 0.00E+00 1.73E+03 0.00E+00 CD-113m 0.00E+00 6.67E+02 2.46E+01 0.00E+00 5.05E+02 0.00E+00 1.00E+03 0.00E+00 CD-115m 0.00E+00 5.31E+02 1.84E+01 0.00E+00 2.77E+02 0.00E+00 3.02E+03 0.00E+00 SN-123 9.36E+03 1.46E+02 2.44E+02 1.47E+02 0.00E+00 0.00E+00 2.47E+03 0.00E+00 SN-125 2.69E+03 5.02E+01 1.20E+02 4.94E+01 0.00E+00 0.00E+00 4.03E+03 0.00E+00 SN-126 2.08E+04 2.73E+02 6.78E+02 7.20E+01 0.00E+00 0.00E+00 9.49E+02 0.00E+00 SB-124 8.02E+02 1.18E+01 2.48E+02 2.13E+00 0.00E+00 5.02E+02 2.47E+03 0.00E+00 SB-125 4.63E+02 4.48E+00 9.53E+01 5.80E-01 0.00E+00 2.68E+02 6.18E+02 0.00E+00 SB-126 2.95E+02 5.79E+00 1.07E+02 2.27E+00 0.00E+00 1.86E+02 3.06E+03 0.00E+00 SB-127 7.68E+01 1.37E+00 2.38E+01 9.78E-01 0.00E+00 3.96E+01 2.03E+03 0.00E+00 TE-125m 8.73E+02 2.92E+02 1.18E+02 2.94E+02 0.00E+00 0.00E+00 4.16E+02 0.00E+00 TE-127m 2.20E+03 7.29E+02 2.66E+02 6.35E+02 5.41E+03 0.00E+00 8.86E+02 0.00E+00 TE-127 1.55E+01 5.18E+00 3.33E+00 1.26E+01 3.78E+01 0.00E+00 3.25E+02 0.00E+00 TE-129m 3.73E+03 1.28E+03 5.74E+02 1.43E+03 9.32E+03 0.00E+00 2.23E+03 0.00E+00 TE-129 8.23E-03 2.84E-03 1.92E-03 6.89E-03 2.05E-02 0.00E+00 6.58E-01 0.00E+00 TE-133m 1.80E-03 8.25E-04 7.88E-04 1.59E-03 5.62E-03 0.00E+00 8.90E-02 0.00E+00 II.4-68 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-16 (Page 3 of 4)
Infant Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 6.57E-05 3.30E-05 3.39E-05 5.88E-05 2.22E-04 0.00E+00 7.53E-04 0.00E+00 I-129 1.08E+03 7.99E+02 5.84E+02 5.12E+05 9.46E+02 0.00E+00 1.60E+01 0.00E+00 I-130 1.15E+02 2.54E+02 1.02E+02 2.84E+04 2.79E+02 0.00E+00 5.44E+01 0.00E+00 I-131 1.30E+03 1.53E+03 6.71E+02 5.02E+05 1.78E+03 0.00E+00 5.45E+01 0.00E+00 TE-131m 4.34E+02 1.75E+02 1.44E+02 3.54E+02 1.20E+03 0.00E+00 2.94E+03 0.00E+00 TE-131 1.42E-08 5.24E-09 3.98E-09 1.27E-08 3.63E-08 0.00E+00 5.73E-07 0.00E+00 I-132 1.68E+00 3.41E+00 1.22E+00 1.60E+02 3.81E+00 0.00E+00 2.76E+00 0.00E+00 TE-132 7.04E+02 3.49E+02 3.25E+02 5.15E+02 2.18E+03 0.00E+00 1.29E+03 0.00E+00 I-133 3.16E+02 4.60E+02 1.35E+02 8.36E+04 5.40E+02 0.00E+00 7.78E+01 0.00E+00 CS-134m 3.77E-01 6.27E-01 3.17E-01 0.00E+00 2.42E-01 5.56E-02 4.96E-01 0.00E+00 CS-134 1.42E+04 2.65E+04 2.67E+03 0.00E+00 6.82E+03 2.79E+03 7.19E+01 0.00E+00 I-134 2.48E-03 5.08E-03 1.81E-03 1.18E-01 5.68E-03 0.00E+00 5.25E-03 0.00E+00 I-135 3.90E+01 7.75E+01 2.83E+01 6.95E+03 8.64E+01 0.00E+00 2.80E+01 0.00E+00 CS-135 5.01E+03 4.56E+03 2.37E+02 0.00E+00 1.30E+03 4.93E+02 1.65E+01 0.00E+00 CS-136 1.68E+03 4.95E+03 1.85E+03 0.00E+00 1.97E+03 4.04E+02 7.52E+01 0.00E+00 CS-137 1.97E+04 2.30E+04 1.63E+03 0.00E+00 6.18E+03 2.50E+03 7.19E+01 0.00E+00 CS-138 3.37E-06 5.47E-06 2.65E-06 0.00E+00 2.73E-06 4.26E-07 8.75E-06 0.00E+00 CS-139 1.02E-22 1.40E-22 5.34E-23 0.00E+00 7.22E-23 1.09E-23 8.78E-24 0.00E+00 BA-139 8.18E-02 5.42E-05 2.37E-03 0.00E+00 3.26E-05 3.29E-05 5.18E+00 0.00E+00 BA-140 6.27E+03 6.27E+00 3.23E+02 0.00E+00 1.49E+00 3.85E+00 1.54E+03 0.00E+00 LA-140 6.46E-01 2.55E-01 6.56E-02 0.00E+00 0.00E+00 0.00E+00 2.99E+03 0.00E+00 BA-141 2.19E-11 1.50E-14 6.92E-13 0.00E+00 9.03E-15 9.14E-15 2.68E-10 0.00E+00 LA-141 1.32E-02 3.82E-03 6.66E-04 0.00E+00 0.00E+00 0.00E+00 4.38E+02 0.00E+00 CE-141 2.93E+00 1.79E+00 2.11E-01 0.00E+00 5.52E-01 0.00E+00 9.24E+02 0.00E+00 BA-142 3.84E-20 3.20E-23 1.89E-21 0.00E+00 1.84E-23 1.93E-23 1.58E-19 0.00E+00 LA-142 2.22E-04 8.14E-05 1.95E-05 0.00E+00 0.00E+00 0.00E+00 1.38E+01 0.00E+00 CE-143 4.33E-01 2.88E+02 3.28E-02 0.00E+00 8.37E-02 0.00E+00 1.68E+03 0.00E+00 PR-143 2.99E+00 1.12E+00 1.48E-01 0.00E+00 4.15E-01 0.00E+00 1.58E+03 0.00E+00 CE-144 1.12E+02 4.59E+01 6.28E+00 0.00E+00 1.85E+01 0.00E+00 6.43E+03 0.00E+00 PR-144 2.96E-15 1.14E-15 1.49E-16 0.00E+00 4.14E-16 0.00E+00 5.32E-11 0.00E+00 ND-147 2.02E+00 2.07E+00 1.27E-01 0.00E+00 7.99E-01 0.00E+00 1.31E+03 0.00E+00 PM-147 1.46E+01 1.23E+00 5.99E-01 0.00E+00 1.84E+00 0.00E+00 3.49E+02 0.00E+00 PM-148m 6.16E+00 1.56E+00 1.23E+00 0.00E+00 1.79E+00 0.00E+00 2.03E+03 0.00E+00 PM-148 2.23E+00 3.22E-01 1.62E-01 0.00E+00 3.85E-01 0.00E+00 3.44E+03 0.00E+00 PM-149 4.44E-01 5.83E-02 2.54E-02 0.00E+00 7.09E-02 0.00E+00 1.57E+03 0.00E+00 PM-151 1.74E-01 2.53E-02 1.28E-02 0.00E+00 3.01E-02 0.00E+00 1.17E+03 0.00E+00 SM-151 1.09E+01 2.51E+00 5.42E-01 0.00E+00 1.71E+00 0.00E+00 2.10E+02 0.00E+00 II.4-69 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-16 (Page 4 of 4)
Infant Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 2.43E-01 1.88E-01 1.44E-02 0.00E+00 3.94E-02 0.00E+00 9.84E+02 0.00E+00 EU-152 2.54E+01 6.74E+00 5.69E+00 0.00E+00 1.89E+01 0.00E+00 5.99E+02 0.00E+00 EU-154 9.94E+01 1.38E+01 8.29E+00 0.00E+00 3.75E+01 0.00E+00 1.73E+03 0.00E+00 EU-155 2.04E+01 2.35E+00 1.22E+00 0.00E+00 5.27E+00 0.00E+00 3.15E+03 0.00E+00 EU-156 4.20E+00 2.60E+00 4.12E-01 0.00E+00 1.20E+00 0.00E+00 2.46E+03 0.00E+00 TB-160 9.71E+00 0.00E+00 1.21E+00 0.00E+00 2.76E+00 0.00E+00 1.29E+03 0.00E+00 HO-166m 4.71E+01 1.01E+01 8.02E+00 0.00E+00 1.34E+01 0.00E+00 3.77E-17 0.00E+00 W-181 3.32E+00 1.02E+00 1.14E-01 0.00E+00 0.00E+00 0.00E+00 1.43E+01 0.00E+00 W-185 1.36E+02 4.24E+01 4.84E+00 0.00E+00 0.00E+00 0.00E+00 6.07E+02 0.00E+00 W-187 2.40E+01 1.67E+01 5.77E+00 0.00E+00 0.00E+00 0.00E+00 9.81E+02 0.00E+00 NP-239 3.61E-01 3.23E-02 1.82E-02 0.00E+00 6.44E-02 0.00E+00 9.33E+02 0.00E+00 U-232 9.12E+05 0.00E+00 8.14E+04 0.00E+00 8.93E+04 0.00E+00 2.65E+03 0.00E+00 U-233 1.91E+05 0.00E+00 1.46E+04 0.00E+00 4.07E+04 0.00E+00 2.45E+03 0.00E+00 U-234 1.84E+05 0.00E+00 1.43E+04 0.00E+00 3.99E+04 0.00E+00 2.40E+03 0.00E+00 U-235 1.76E+05 0.00E+00 1.34E+04 0.00E+00 3.74E+04 0.00E+00 3.05E+03 0.00E+00 U-236 1.76E+05 0.00E+00 1.37E+04 0.00E+00 3.80E+04 0.00E+00 2.25E+03 0.00E+00 U-237 1.77E+01 0.00E+00 4.72E+00 0.00E+00 4.40E+01 0.00E+00 7.55E+02 0.00E+00 U-238 1.68E+05 0.00E+00 1.25E+04 0.00E+00 3.50E+04 0.00E+00 2.15E+03 0.00E+00 NP-237 9.04E+04 5.99E+03 3.96E+03 0.00E+00 2.39E+04 0.00E+00 3.10E+03 0.00E+00 NP-238 3.97E+00 9.98E-02 6.14E-02 0.00E+00 2.18E-01 0.00E+00 1.33E+03 0.00E+00 PU-238 4.82E+04 5.65E+03 1.28E+03 0.00E+00 4.56E+03 0.00E+00 2.85E+03 0.00E+00 PU-239 5.20E+04 5.84E+03 1.33E+03 0.00E+00 4.82E+03 0.00E+00 2.60E+03 0.00E+00 PU-240 5.20E+04 5.84E+03 1.33E+03 0.00E+00 4.82E+03 0.00E+00 2.65E+03 0.00E+00 PU-241 1.60E+03 6.63E+01 3.32E+01 0.00E+00 1.19E+02 0.00E+00 5.46E+01 0.00E+00 PU-242 4.82E+04 5.61E+03 1.28E+03 0.00E+00 4.63E+03 0.00E+00 2.55E+03 0.00E+00 PU-244 5.61E+04 6.44E+03 1.47E+03 0.00E+00 5.31E+03 0.00E+00 3.80E+03 0.00E+00 AM-241 5.50E+04 4.78E+04 4.11E+03 0.00E+00 2.47E+04 0.00E+00 2.90E+03 0.00E+00 AM-242m 5.69E+04 4.60E+04 4.26E+03 0.00E+00 2.50E+04 0.00E+00 3.65E+03 0.00E+00 AM-243 5.42E+04 4.63E+04 3.99E+03 0.00E+00 2.40E+04 0.00E+00 3.40E+03 0.00E+00 CM-242 5.15E+03 4.77E+03 3.42E+02 0.00E+00 9.85E+02 0.00E+00 3.09E+03 0.00E+00 CM-243 5.27E+04 4.33E+04 3.38E+03 0.00E+00 1.23E+04 0.00E+00 3.05E+03 0.00E+00 CM-244 4.44E+04 3.65E+04 2.86E+03 0.00E+00 1.02E+04 0.00E+00 2.95E+03 0.00E+00 CM-245 6.74E+04 5.46E+04 4.26E+03 0.00E+00 1.63E+04 0.00E+00 2.75E+03 0.00E+00 CM-246 6.67E+04 5.46E+04 4.26E+03 0.00E+00 1.62E+04 0.00E+00 2.70E+03 0.00E+00 CM-247 6.52E+04 5.39E+04 4.18E+03 0.00E+00 1.60E+04 0.00E+00 3.55E+03 0.00E+00 CM-248 5.39E+05 4.45E+05 3.45E+04 0.00E+00 1.32E+05 0.00E+00 5.73E+04 0.00E+00 CF-252 4.59E+04 0.00E+00 1.11E+03 0.00E+00 0.00E+00 0.00E+00 1.13E+04 0.00E+00 II.4-70 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-17 (Page 1 of 4)
Child Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 6.75E+00 6.75E+00 6.75E+00 6.75E+00 6.75E+00 6.75E+00 0.00E+00 C-14 7.04E+02 1.41E+02 1.41E+02 1.41E+02 1.41E+02 1.41E+02 1.41E+02 0.00E+00 NA-22 3.42E+03 3.42E+03 3.42E+03 3.42E+03 3.42E+03 3.42E+03 3.42E+03 0.00E+00 NA-24 1.94E+02 1.94E+02 1.94E+02 1.94E+02 1.94E+02 1.94E+02 1.94E+02 0.00E+00 P-32 4.69E+04 2.19E+03 1.81E+03 0.00E+00 0.00E+00 0.00E+00 1.30E+03 0.00E+00 CA-41 2.02E+04 0.00E+00 2.21E+03 0.00E+00 0.00E+00 0.00E+00 1.11E+01 0.00E+00 SC-46 1.14E+00 1.57E+00 6.03E-01 0.00E+00 1.39E+00 0.00E+00 2.29E+03 0.00E+00 CR-51 0.00E+00 0.00E+00 5.12E-01 2.84E-01 7.76E-02 5.19E-01 2.71E+01 0.00E+00 MN-54 0.00E+00 6.22E+02 1.66E+02 0.00E+00 1.74E+02 0.00E+00 5.22E+02 0.00E+00 FE-55 6.69E+02 3.55E+02 1.10E+02 0.00E+00 0.00E+00 2.01E+02 6.58E+01 0.00E+00 MN-56 0.00E+00 7.72E-01 1.74E-01 0.00E+00 9.34E-01 0.00E+00 1.12E+02 0.00E+00 CO-57 0.00E+00 2.87E+01 5.80E+01 0.00E+00 0.00E+00 0.00E+00 2.35E+02 0.00E+00 CO-58 0.00E+00 1.04E+02 3.19E+02 0.00E+00 0.00E+00 0.00E+00 6.08E+02 0.00E+00 FE-59 9.53E+02 1.54E+03 7.68E+02 0.00E+00 0.00E+00 4.47E+02 1.61E+03 0.00E+00 CO-60 0.00E+00 3.08E+02 9.08E+02 0.00E+00 0.00E+00 0.00E+00 1.71E+03 0.00E+00 NI-59 2.34E+03 6.23E+02 3.97E+02 0.00E+00 0.00E+00 0.00E+00 4.13E+01 0.00E+00 NI-63 3.13E+04 1.68E+03 1.07E+03 0.00E+00 0.00E+00 0.00E+00 1.13E+02 0.00E+00 CU-64 0.00E+00 7.41E+00 4.48E+00 0.00E+00 1.79E+01 0.00E+00 3.48E+02 0.00E+00 NI-65 4.76E+00 4.48E-01 2.62E-01 0.00E+00 0.00E+00 0.00E+00 5.49E+01 0.00E+00 ZN-65 7.96E+02 2.12E+03 1.32E+03 0.00E+00 1.34E+03 0.00E+00 3.73E+02 0.00E+00 ZN-69m 2.26E+01 3.85E+01 4.55E+00 0.00E+00 2.24E+01 0.00E+00 1.25E+03 0.00E+00 ZN-69 3.22E-04 4.66E-04 4.31E-05 0.00E+00 2.83E-04 0.00E+00 2.94E-02 0.00E+00 SE-79 0.00E+00 4.91E+02 1.09E+02 0.00E+00 7.98E+02 0.00E+00 3.22E+01 0.00E+00 BR-82 0.00E+00 0.00E+00 3.47E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 3.07E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 1.76E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.31E-76 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 3.83E+03 2.35E+03 0.00E+00 0.00E+00 0.00E+00 2.46E+02 0.00E+00 RB-87 0.00E+00 2.30E+03 1.07E+03 0.00E+00 0.00E+00 0.00E+00 3.45E+01 0.00E+00 RB-88 0.00E+00 7.37E-12 5.12E-12 0.00E+00 0.00E+00 0.00E+00 3.61E-13 0.00E+00 RB-89 0.00E+00 6.25E-14 5.55E-14 0.00E+00 0.00E+00 0.00E+00 5.45E-16 0.00E+00 SR-89 7.63E+04 0.00E+00 2.18E+03 0.00E+00 0.00E+00 0.00E+00 2.95E+03 0.00E+00 SR-90 1.49E+06 0.00E+00 3.00E+04 0.00E+00 0.00E+00 0.00E+00 1.33E+04 0.00E+00 Y-90 2.10E+00 0.00E+00 5.62E-02 0.00E+00 0.00E+00 0.00E+00 5.98E+03 0.00E+00 SR-91 5.82E+02 0.00E+00 2.20E+01 0.00E+00 0.00E+00 0.00E+00 1.29E+03 0.00E+00 Y-91m 9.71E-07 0.00E+00 3.53E-08 0.00E+00 0.00E+00 0.00E+00 1.90E-03 0.00E+00 Y-91 3.48E+01 0.00E+00 9.32E-01 0.00E+00 0.00E+00 0.00E+00 4.64E+03 0.00E+00 II.4-71 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-17 (Page 2 of 4)
Child Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 2.44E+01 0.00E+00 9.79E-01 0.00E+00 0.00E+00 0.00E+00 4.62E+02 0.00E+00 Y-92 2.00E-02 0.00E+00 5.72E-04 0.00E+00 0.00E+00 0.00E+00 5.78E+02 0.00E+00 Y-93 2.91E-01 0.00E+00 8.00E-03 0.00E+00 0.00E+00 0.00E+00 4.34E+03 0.00E+00 NB-93m 6.11E+00 1.53E+00 5.01E-01 0.00E+00 1.65E+00 0.00E+00 2.30E+02 0.00E+00 NB-95 1.30E+00 5.05E-01 3.61E-01 0.00E+00 4.74E-01 0.00E+00 9.34E+02 0.00E+00 NB-97 1.25E-05 2.25E-06 1.05E-06 0.00E+00 2.50E-06 0.00E+00 6.95E-01 0.00E+00 ZR-93 9.72E+00 3.64E+00 2.59E+00 0.00E+00 1.41E+01 0.00E+00 1.38E+03 0.00E+00 ZR-95 6.72E+00 1.48E+00 1.31E+00 0.00E+00 2.11E+00 0.00E+00 1.54E+03 0.00E+00 ZR-97 2.49E-01 3.59E-02 2.12E-02 0.00E+00 5.16E-02 0.00E+00 5.45E+03 0.00E+00 MO-93 0.00E+00 1.40E+03 5.04E+01 0.00E+00 3.70E+02 0.00E+00 7.10E+01 0.00E+00 MO-99 0.00E+00 6.83E+02 1.69E+02 0.00E+00 1.46E+03 0.00E+00 5.65E+02 0.00E+00 TC-99 3.11E+01 3.47E+01 1.25E+01 0.00E+00 4.09E+02 3.07E+00 3.64E+02 0.00E+00 TC-99m 1.35E-02 2.65E-02 4.39E-01 0.00E+00 3.85E-01 1.34E-02 1.51E+01 0.00E+00 TC-101 3.40E-17 3.55E-17 4.51E-16 0.00E+00 6.06E-16 1.88E-17 1.13E-16 0.00E+00 RU-103 4.22E+01 0.00E+00 1.62E+01 0.00E+00 1.06E+02 0.00E+00 1.09E+03 0.00E+00 RU-105 5.77E-01 0.00E+00 2.09E-01 0.00E+00 5.07E+00 0.00E+00 3.76E+02 0.00E+00 RU-106 6.81E+02 0.00E+00 8.49E+01 0.00E+00 9.19E+02 0.00E+00 1.06E+04 0.00E+00 RH-105 2.37E+01 1.27E+01 1.09E+01 0.00E+00 5.06E+01 0.00E+00 7.87E+02 0.00E+00 PD-107 0.00E+00 2.75E+01 2.33E+00 0.00E+00 2.30E+02 0.00E+00 5.46E+01 0.00E+00 PD-109 0.00E+00 1.78E+01 5.33E+00 0.00E+00 9.54E+01 0.00E+00 1.05E+03 0.00E+00 AG-110m 3.13E+01 2.12E+01 1.69E+01 0.00E+00 3.94E+01 0.00E+00 2.52E+03 0.00E+00 AG-111 1.38E+01 4.31E+00 2.85E+00 0.00E+00 1.30E+01 0.00E+00 2.64E+03 0.00E+00 CD-113m 0.00E+00 5.94E+02 2.53E+01 0.00E+00 6.11E+02 0.00E+00 1.53E+03 0.00E+00 CD-115m 0.00E+00 3.40E+02 1.45E+01 0.00E+00 2.53E+02 0.00E+00 4.63E+03 0.00E+00 SN-123 7.72E+03 9.58E+01 1.88E+02 1.02E+02 0.00E+00 0.00E+00 3.79E+03 0.00E+00 SN-125 1.99E+03 3.00E+01 8.93E+01 3.12E+01 0.00E+00 0.00E+00 6.18E+03 0.00E+00 SN-126 1.94E+04 2.42E+02 5.51E+02 6.64E+01 0.00E+00 0.00E+00 1.46E+03 0.00E+00 SB-124 6.43E+02 8.34E+00 2.25E+02 1.42E+00 0.00E+00 3.57E+02 4.02E+03 0.00E+00 SB-125 4.17E+02 3.21E+00 8.73E+01 3.86E-01 0.00E+00 2.32E+02 9.95E+02 0.00E+00 SB-126 2.49E+02 3.81E+00 8.95E+01 1.46E+00 0.00E+00 1.19E+02 5.02E+03 0.00E+00 SB-127 5.64E+01 8.73E-01 1.96E+01 6.28E-01 0.00E+00 2.45E+01 3.18E+03 0.00E+00 TE-125m 6.60E+02 1.79E+02 8.80E+01 1.85E+02 0.00E+00 0.00E+00 6.37E+02 0.00E+00 TE-127m 1.68E+03 4.52E+02 1.99E+02 4.01E+02 4.78E+03 0.00E+00 1.36E+03 0.00E+00 TE-127 1.13E+01 3.04E+00 2.42E+00 7.80E+00 3.20E+01 0.00E+00 4.40E+02 0.00E+00 TE-129m 2.81E+03 7.84E+02 4.36E+02 9.05E+02 8.24E+03 0.00E+00 3.42E+03 0.00E+00 TE-129 6.00E-03 1.67E-03 1.42E-03 4.28E-03 1.75E-02 0.00E+00 3.73E-01 0.00E+00 TE-133m 1.33E-03 5.39E-04 6.68E-04 1.03E-03 5.12E-03 0.00E+00 4.11E-02 0.00E+00 II.4-72 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-17 (Page 3 of 4)
Child Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 4.90E-05 2.20E-05 2.94E-05 3.88E-05 2.04E-04 0.00E+00 2.24E-04 0.00E+00 I-129 8.09E+02 4.97E+02 4.44E+02 3.25E+05 8.38E+02 0.00E+00 2.50E+01 0.00E+00 I-130 8.67E+01 1.75E+02 9.03E+01 1.93E+04 2.62E+02 0.00E+00 8.20E+01 0.00E+00 I-131 9.59E+02 9.65E+02 5.48E+02 3.19E+05 1.58E+03 0.00E+00 8.59E+01 0.00E+00 TE-131m 3.18E+02 1.10E+02 1.17E+02 2.26E+02 1.06E+03 0.00E+00 4.46E+03 0.00E+00 TE-131 1.03E-08 3.15E-09 3.08E-09 7.91E-09 3.13E-08 0.00E+00 5.43E-08 0.00E+00 I-132 1.25E+00 2.30E+00 1.06E+00 1.07E+02 3.52E+00 0.00E+00 2.71E+00 0.00E+00 TE-132 5.29E+02 2.34E+02 2.83E+02 3.41E+02 2.17E+03 0.00E+00 2.36E+03 0.00E+00 I-133 2.31E+02 2.86E+02 1.08E+02 5.31E+04 4.76E+02 0.00E+00 1.15E+02 0.00E+00 CS-134m 2.79E-01 4.13E-01 2.70E-01 0.00E+00 2.18E-01 3.60E-02 5.22E-01 0.00E+00 CS-134 1.36E+04 2.23E+04 4.71E+03 0.00E+00 6.92E+03 2.48E+03 1.20E+02 0.00E+00 I-134 1.85E-03 3.43E-03 1.58E-03 7.90E-02 5.25E-03 0.00E+00 2.28E-03 0.00E+00 I-135 2.89E+01 5.21E+01 2.46E+01 4.61E+03 7.99E+01 0.00E+00 3.97E+01 0.00E+00 CS-135 4.83E+03 3.37E+03 3.45E+02 0.00E+00 1.19E+03 3.96E+02 2.52E+01 0.00E+00 CS-136 1.33E+03 3.66E+03 2.37E+03 0.00E+00 1.95E+03 2.91E+02 1.29E+02 0.00E+00 CS-137 1.90E+04 1.82E+04 2.69E+03 0.00E+00 5.94E+03 2.14E+03 1.14E+02 0.00E+00 CS-138 2.47E-06 3.43E-06 2.17E-06 0.00E+00 2.41E-06 2.60E-07 1.58E-06 0.00E+00 CS-139 7.39E-23 8.21E-23 3.95E-23 0.00E+00 6.17E-23 6.22E-24 7.39E-27 0.00E+00 BA-139 5.94E-02 3.17E-05 1.72E-03 0.00E+00 2.77E-05 1.87E-05 3.43E+00 0.00E+00 BA-140 4.71E+03 4.13E+00 2.75E+02 0.00E+00 1.34E+00 2.46E+00 2.39E+03 0.00E+00 LA-140 4.78E-01 1.67E-01 5.63E-02 0.00E+00 0.00E+00 0.00E+00 4.66E+03 0.00E+00 BA-141 1.60E-11 8.93E-15 5.19E-13 0.00E+00 7.73E-15 5.25E-14 9.09E-12 0.00E+00 LA-141 9.59E-03 2.24E-03 4.85E-04 0.00E+00 0.00E+00 0.00E+00 4.97E+02 0.00E+00 CE-141 2.29E+00 1.14E+00 1.69E-01 0.00E+00 5.00E-01 0.00E+00 1.42E+03 0.00E+00 BA-142 2.82E-20 2.03E-23 1.57E-21 0.00E+00 1.64E-23 1.19E-23 3.68E-22 0.00E+00 LA-142 1.63E-04 5.20E-05 1.63E-05 0.00E+00 0.00E+00 0.00E+00 1.03E+01 0.00E+00 CE-143 3.16E-01 1.71E+02 2.48E-02 0.00E+00 7.19E-02 0.00E+00 2.51E+03 0.00E+00 PR-143 2.23E+00 6.70E-01 1.11E-01 0.00E+00 3.63E-01 0.00E+00 2.41E+03 0.00E+00 CE-144 1.21E+02 3.79E+01 6.45E+00 0.00E+00 2.10E+01 0.00E+00 9.89E+03 0.00E+00 PR-144 2.15E-15 6.65E-16 1.08E-16 0.00E+00 3.52E-16 0.00E+00 1.43E-12 0.00E+00 ND-147 1.57E+00 1.27E+00 9.87E-02 0.00E+00 6.99E-01 0.00E+00 2.02E+03 0.00E+00 PM-147 1.85E+01 1.32E+00 7.10E-01 0.00E+00 2.33E+00 0.00E+00 5.35E+02 0.00E+00 PM-148m 5.95E+00 1.18E+00 1.18E+00 0.00E+00 1.76E+00 0.00E+00 3.34E+03 0.00E+00 PM-148 1.65E+00 1.98E-01 1.28E-01 0.00E+00 3.37E-01 0.00E+00 5.29E+03 0.00E+00 PM-149 3.23E-01 3.43E-02 1.86E-02 0.00E+00 6.07E-02 0.00E+00 2.34E+03 0.00E+00 PM-151 1.27E-01 1.54E-02 1.00E-02 0.00E+00 2.61E-02 0.00E+00 1.75E+03 0.00E+00 SM-151 1.49E+01 2.22E+00 6.99E-01 0.00E+00 2.29E+00 0.00E+00 3.22E+02 0.00E+00 II.4-73 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-17 (Page 4 of 4)
Child Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.78E-01 1.11E-01 1.07E-02 0.00E+00 3.37E-02 0.00E+00 1.47E+03 0.00E+00 EU-152 3.58E+01 6.52E+00 7.74E+00 0.00E+00 2.75E+01 0.00E+00 1.07E+03 0.00E+00 EU-154 1.34E+02 1.21E+01 1.10E+01 0.00E+00 5.29E+01 0.00E+00 2.80E+03 0.00E+00 EU-155 2.81E+01 2.02E+00 1.58E+00 0.00E+00 7.57E+00 0.00E+00 5.06E+03 0.00E+00 EU-156 3.20E+00 1.71E+00 3.55E-01 0.00E+00 1.10E+00 0.00E+00 3.89E+03 0.00E+00 TB-160 9.62E+00 0.00E+00 1.19E+00 0.00E+00 2.86E+00 0.00E+00 2.13E+03 0.00E+00 HO-166m 6.29E+01 1.32E+01 1.11E+01 0.00E+00 1.87E+01 0.00E+00 5.82E-17 0.00E+00 W-181 2.46E+00 6.04E-01 8.30E-02 0.00E+00 0.00E+00 0.00E+00 2.20E+01 0.00E+00 W-185 1.00E+02 2.50E+01 3.51E+00 0.00E+00 0.00E+00 0.00E+00 9.33E+02 0.00E+00 W-187 1.76E+01 1.04E+01 4.68E+00 0.00E+00 0.00E+00 0.00E+00 1.47E+03 0.00E+00 NP-239 2.64E-01 1.89E-02 1.33E-02 0.00E+00 5.48E-02 0.00E+00 1.40E+03 0.00E+00 U-232 1.02E+06 0.00E+00 7.34E+04 0.00E+00 7.80E+04 0.00E+00 4.06E+03 0.00E+00 U-233 2.17E+05 0.00E+00 1.31E+04 0.00E+00 3.55E+04 0.00E+00 3.76E+03 0.00E+00 U-234 2.08E+05 0.00E+00 1.29E+04 0.00E+00 3.48E+04 0.00E+00 3.68E+03 0.00E+00 U-235 1.99E+05 0.00E+00 1.21E+04 0.00E+00 3.27E+04 0.00E+00 4.68E+03 0.00E+00 U-236 1.99E+05 0.00E+00 1.23E+04 0.00E+00 3.34E+04 0.00E+00 3.45E+03 0.00E+00 U-237 1.31E+01 0.00E+00 3.47E+00 0.00E+00 3.77E+01 0.00E+00 1.15E+03 0.00E+00 U-238 1.90E+05 0.00E+00 1.13E+04 0.00E+00 3.05E+04 0.00E+00 3.30E+03 0.00E+00 NP-237 1.30E+05 8.56E+03 5.70E+03 0.00E+00 3.52E+04 0.00E+00 4.75E+03 0.00E+00 NP-238 2.88E+00 5.83E-02 4.49E-02 0.00E+00 1.86E-01 0.00E+00 2.00E+03 0.00E+00 PU-238 6.93E+04 8.03E+03 1.84E+03 0.00E+00 6.70E+03 0.00E+00 4.37E+03 0.00E+00 PU-239 7.51E+04 8.03E+03 1.93E+03 0.00E+00 7.10E+03 0.00E+00 3.99E+03 0.00E+00 PU-240 7.45E+04 8.33E+03 1.93E+03 0.00E+00 7.10E+03 0.00E+00 4.06E+03 0.00E+00 PU-241 2.25E+03 9.20E+01 4.68E+01 0.00E+00 1.72E+02 0.00E+00 8.38E+01 0.00E+00 PU-242 6.93E+04 8.03E+03 1.86E+03 0.00E+00 6.81E+03 0.00E+00 3.91E+03 0.00E+00 PU-244 8.09E+04 9.20E+04 2.13E+03 0.00E+00 7.86E+03 0.00E+00 5.82E+03 0.00E+00 AM-241 7.92E+04 6.81E+04 5.94E+03 0.00E+00 3.63E+04 0.00E+00 4.45E+03 0.00E+00 AM-242m 8.15E+04 6.52E+04 6.05E+03 0.00E+00 3.67E+04 0.00E+00 5.59E+03 0.00E+00 AM-243 7.80E+04 6.58E+04 5.72E+03 0.00E+00 3.53E+04 0.00E+00 5.21E+03 0.00E+00 CM-242 5.10E+03 4.07E+03 3.39E+02 0.00E+00 1.09E+03 0.00E+00 4.74E+03 0.00E+00 CM-243 7.45E+04 6.05E+04 4.80E+03 0.00E+00 1.79E+04 0.00E+00 4.67E+03 0.00E+00 CM-244 6.29E+04 5.09E+04 4.03E+03 0.00E+00 1.48E+04 0.00E+00 4.52E+03 0.00E+00 CM-245 9.72E+04 7.80E+04 6.11E+03 0.00E+00 2.39E+04 0.00E+00 4.22E+03 0.00E+00 CM-246 9.61E+04 7.80E+04 6.11E+03 0.00E+00 2.39E+04 0.00E+00 4.14E+03 0.00E+00 CM-247 9.37E+04 7.68E+04 6.00E+03 0.00E+00 2.35E+04 0.00E+00 5.44E+03 0.00E+00 CM-248 7.80E+05 6.35E+05 4.96E+04 0.00E+00 1.94E+05 0.00E+00 8.79E+04 0.00E+00 CF-252 6.11E+04 0.00E+00 1.48E+03 0.00E+00 0.00E+00 0.00E+00 1.72E+04 0.00E+00 II.4-74 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-18 (Page 1 of 4)
Teen Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 3.52E+00 3.52E+00 3.52E+00 3.52E+00 3.52E+00 3.52E+00 0.00E+00 C-14 2.36E+02 4.73E+01 4.73E+01 4.73E+01 4.73E+01 4.73E+01 4.73E+01 0.00E+00 NA-22 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 0.00E+00 NA-24 7.69E+01 7.69E+01 7.69E+01 7.69E+01 7.69E+01 7.69E+01 7.69E+01 0.00E+00 P-32 1.57E+04 9.72E+02 6.08E+02 0.00E+00 0.00E+00 0.00E+00 1.32E+03 0.00E+00 CA-41 1.15E+04 0.00E+00 1.24E+03 0.00E+00 0.00E+00 0.00E+00 1.14E+01 0.00E+00 SC-46 4.20E-01 8.18E-01 2.42E-01 0.00E+00 7.83E-01 0.00E+00 2.78E+03 0.00E+00 CR-51 0.00E+00 0.00E+00 2.07E-01 1.15E-01 4.54E-02 2.96E-01 3.48E+01 0.00E+00 MN-54 0.00E+00 3.43E+02 6.80E+01 0.00E+00 1.02E+02 0.00E+00 7.04E+02 0.00E+00 FE-55 2.20E+02 1.56E+02 3.64E+01 0.00E+00 0.00E+00 9.89E+01 6.75E+01 0.00E+00 MN-56 0.00E+00 3.65E-01 6.50E-02 0.00E+00 4.63E-01 0.00E+00 2.41E+01 0.00E+00 CO-57 0.00E+00 1.38E+01 2.32E+01 0.00E+00 0.00E+00 0.00E+00 2.58E+02 0.00E+00 CO-58 0.00E+00 5.63E+01 1.30E+02 0.00E+00 0.00E+00 0.00E+00 7.76E+02 0.00E+00 FE-59 3.39E+02 7.91E+02 3.06E+02 0.00E+00 0.00E+00 2.50E+02 1.87E+03 0.00E+00 CO-60 0.00E+00 1.64E+02 3.68E+02 0.00E+00 0.00E+00 0.00E+00 2.13E+03 0.00E+00 NI-59 7.68E+02 2.71E+02 1.30E+02 0.00E+00 0.00E+00 0.00E+00 4.26E+01 0.00E+00 NI-63 1.03E+04 7.28E+02 3.49E+02 0.00E+00 0.00E+00 0.00E+00 1.16E+02 0.00E+00 CU-64 0.00E+00 3.48E+00 1.64E+00 0.00E+00 8.80E+00 0.00E+00 2.70E+02 0.00E+00 NI-65 1.61E+00 2.05E-01 9.36E-02 0.00E+00 0.00E+00 0.00E+00 1.11E+01 0.00E+00 ZN-65 3.35E+02 1.16E+03 5.42E+02 0.00E+00 7.44E+02 0.00E+00 4.92E+02 0.00E+00 ZN-69m 7.63E+00 1.80E+01 1.65E+00 0.00E+00 1.09E+01 0.00E+00 9.89E+02 0.00E+00 ZN-69 1.08E-04 2.06E-04 1.44E-05 0.00E+00 1.35E-04 0.00E+00 3.80E-04 0.00E+00 SE-79 0.00E+00 2.17E+02 3.65E+01 0.00E+00 3.78E+02 0.00E+00 3.32E+01 0.00E+00 BR-82 0.00E+00 0.00E+00 1.40E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 1.03E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 6.42E-07 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 4.38E-77 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.70E+03 8.00E+02 0.00E+00 0.00E+00 0.00E+00 2.52E+02 0.00E+00 RB-87 0.00E+00 1.02E+03 3.56E+02 0.00E+00 0.00E+00 0.00E+00 3.56E+01 0.00E+00 RB-88 0.00E+00 3.30E-12 1.76E-12 0.00E+00 0.00E+00 0.00E+00 2.83E-19 0.00E+00 RB-89 0.00E+00 2.94E-14 2.08E-14 0.00E+00 0.00E+00 0.00E+00 4.50E-23 0.00E+00 SR-89 2.54E+04 0.00E+00 7.29E+02 0.00E+00 0.00E+00 0.00E+00 3.03E+03 0.00E+00 SR-90 5.94E+05 0.00E+00 1.19E+04 0.00E+00 0.00E+00 0.00E+00 1.36E+04 0.00E+00 Y-90 7.01E-01 0.00E+00 1.89E-02 0.00E+00 0.00E+00 0.00E+00 5.78E+03 0.00E+00 SR-91 1.96E+02 0.00E+00 7.79E+00 0.00E+00 0.00E+00 0.00E+00 8.88E+02 0.00E+00 Y-91m 3.28E-07 0.00E+00 1.25E-08 0.00E+00 0.00E+00 0.00E+00 1.55E-05 0.00E+00 Y-91 1.16E+01 0.00E+00 3.12E-01 0.00E+00 0.00E+00 0.00E+00 4.77E+03 0.00E+00 II.4-75 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-18 (Page 2 of 4)
Teen Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 8.25E+00 0.00E+00 3.52E-01 0.00E+00 0.00E+00 0.00E+00 2.10E+02 0.00E+00 Y-92 6.72E-03 0.00E+00 1.94E-04 0.00E+00 0.00E+00 0.00E+00 1.84E+02 0.00E+00 Y-93 9.79E-02 0.00E+00 2.68E-03 0.00E+00 0.00E+00 0.00E+00 2.99E+03 0.00E+00 NB-93m 2.00E+00 6.58E-01 1.65E-01 0.00E+00 7.68E-01 0.00E+00 2.37E+02 0.00E+00 NB-95 4.74E-01 2.63E-01 1.45E-01 0.00E+00 2.55E-01 0.00E+00 1.12E+03 0.00E+00 NB-97 4.23E-06 1.05E-06 3.83E-07 0.00E+00 1.23E-06 0.00E+00 2.51E-02 0.00E+00 ZR-93 3.22E+00 1.59E+00 8.67E-01 0.00E+00 5.62E+00 0.00E+00 1.50E+03 0.00E+00 ZR-95 2.39E+00 7.53E-01 5.18E-01 0.00E+00 1.11E+00 0.00E+00 1.74E+03 0.00E+00 ZR-97 8.43E-02 1.67E-02 7.69E-03 0.00E+00 2.53E-02 0.00E+00 4.52E+03 0.00E+00 MO-93 0.00E+00 6.17E+02 1.69E+01 0.00E+00 1.77E+02 0.00E+00 7.51E+01 0.00E+00 MO-99 0.00E+00 3.10E+02 5.90E+01 0.00E+00 7.08E+02 0.00E+00 5.54E+02 0.00E+00 TC-99 1.04E+01 1.53E+01 4.17E+00 0.00E+00 1.94E+02 1.58E+00 3.75E+02 0.00E+00 TC-99m 4.85E-03 1.35E-02 1.75E-01 0.00E+00 2.02E-01 7.52E-03 8.89E+00 0.00E+00 TC-101 1.14E-17 1.62E-17 1.60E-16 0.00E+00 2.94E-16 9.90E-18 2.78E-24 0.00E+00 RU-103 1.47E+01 0.00E+00 6.29E+00 0.00E+00 5.19E+01 0.00E+00 1.23E+03 0.00E+00 RU-105 1.95E-01 0.00E+00 7.57E-02 0.00E+00 2.46E+00 0.00E+00 1.57E+02 0.00E+00 RU-106 2.28E+02 0.00E+00 2.87E+01 0.00E+00 4.40E+02 0.00E+00 1.09E+04 0.00E+00 RH-105 7.96E+00 5.75E+00 3.77E+00 0.00E+00 2.44E+01 0.00E+00 7.32E+02 0.00E+00 PD-107 0.00E+00 1.21E+01 7.80E-01 0.00E+00 1.09E+02 0.00E+00 5.62E+01 0.00E+00 PD-109 0.00E+00 7.87E+00 1.79E+00 0.00E+00 4.55E+01 0.00E+00 7.94E+02 0.00E+00 AG-110m 1.19E+01 1.13E+01 6.86E+00 0.00E+00 2.15E+01 0.00E+00 3.17E+03 0.00E+00 AG-111 4.61E+00 1.91E+00 9.61E-01 0.00E+00 6.22E+00 0.00E+00 2.67E+03 0.00E+00 CD-113m 0.00E+00 2.63E+02 8.44E+00 0.00E+00 2.90E+02 0.00E+00 1.58E+03 0.00E+00 CD-115m 0.00E+00 1.50E+02 4.85E+00 0.00E+00 1.20E+02 0.00E+00 4.75E+03 0.00E+00 SN-123 2.58E+03 4.23E+01 6.27E+01 3.39E+01 0.00E+00 0.00E+00 3.90E+03 0.00E+00 SN-125 6.68E+02 1.33E+01 3.02E+01 1.04E+01 0.00E+00 0.00E+00 6.29E+03 0.00E+00 SN-126 6.75E+03 1.26E+02 1.92E+02 3.31E+01 0.00E+00 0.00E+00 1.50E+03 0.00E+00 SB-124 2.24E+02 4.13E+00 8.74E+01 5.08E-01 0.00E+00 1.96E+02 4.52E+03 0.00E+00 SB-125 1.44E+02 1.58E+00 3.38E+01 1.38E-01 0.00E+00 1.27E+02 1.12E+03 0.00E+00 SB-126 9.00E+01 1.84E+00 3.23E+01 5.09E-01 0.00E+00 6.45E+01 5.33E+03 0.00E+00 SB-127 1.93E+01 4.13E-01 7.29E+00 2.17E-01 0.00E+00 1.31E+01 3.28E+03 0.00E+00 TE-125m 2.22E+02 7.99E+01 2.96E+01 6.19E+01 0.00E+00 0.00E+00 6.54E+02 0.00E+00 TE-127m 5.61E+02 1.99E+02 6.67E+01 1.33E+02 2.27E+03 0.00E+00 1.40E+03 0.00E+00 TE-127 3.78E+00 1.34E+00 8.13E-01 2.61E+00 1.53E+01 0.00E+00 2.92E+02 0.00E+00 TE-129m 9.39E+02 3.49E+02 1.49E+02 3.03E+02 3.93E+03 0.00E+00 3.53E+03 0.00E+00 TE-129 2.01E-03 7.48E-04 4.88E-04 1.43E-03 8.42E-03 0.00E+00 1.10E-02 0.00E+00 TE-133m 4.59E-04 2.61E-04 2.54E-04 3.64E-04 2.58E-03 0.00E+00 1.05E-03 0.00E+00 II.4-76 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-18 (Page 3 of 4)
Teen Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 1.70E-05 1.09E-05 1.14E-05 1.39E-05 1.04E-04 0.00E+00 6.31E-07 0.00E+00 I-129 2.71E+02 2.28E+02 3.81E+02 2.78E+05 4.08E+02 0.00E+00 2.66E+01 0.00E+00 I-130 3.06E+01 8.85E+01 3.53E+01 7.22E+03 1.36E+02 0.00E+00 6.80E+01 0.00E+00 I-131 3.26E+02 4.57E+02 2.45E+02 1.33E+05 7.86E+02 0.00E+00 9.03E+01 0.00E+00 TE-131m 1.08E+02 5.16E+01 4.31E+01 7.77E+01 5.38E+02 0.00E+00 4.14E+03 0.00E+00 TE-131 3.48E-09 1.43E-09 1.09E-09 2.68E-09 1.52E-08 0.00E+00 2.85E-10 0.00E+00 I-132 4.37E-01 1.14E+00 4.10E-01 3.85E+01 1.80E+00 0.00E+00 4.98E-01 0.00E+00 TE-132 1.83E+02 1.16E+02 1.09E+02 1.22E+02 1.11E+03 0.00E+00 3.66E+03 0.00E+00 I-133 7.84E+01 1.33E+02 4.06E+01 1.86E+04 2.33E+02 0.00E+00 1.01E+02 0.00E+00 CS-134m 9.72E-02 2.01E-01 1.04E-01 0.00E+00 1.12E-01 1.97E-02 1.34E-01 0.00E+00 CS-134 4.87E+03 1.15E+04 5.32E+03 0.00E+00 3.64E+03 1.39E+03 1.43E+02 0.00E+00 I-134 6.44E-04 1.71E-03 6.13E-04 2.84E-02 2.69E-03 0.00E+00 2.25E-05 0.00E+00 I-135 1.01E+01 2.60E+01 9.63E+00 1.67E+03 4.10E+01 0.00E+00 2.88E+01 0.00E+00 CS-135 1.62E+03 1.48E+03 3.47E+02 0.00E+00 5.66E+02 2.05E+02 2.60E+01 0.00E+00 CS-136 4.87E+02 1.92E+03 1.29E+03 0.00E+00 1.04E+03 1.64E+02 1.54E+02 0.00E+00 CS-137 6.52E+03 8.67E+03 3.02E+03 0.00E+00 2.95E+03 1.15E+03 1.23E+02 0.00E+00 CS-138 8.39E-07 1.61E-06 8.06E-07 0.00E+00 1.19E-06 1.38E-07 7.31E-10 0.00E+00 CS-139 2.48E-23 3.66E-23 1.34E-23 0.00E+00 2.95E-23 3.23E-24 1.70E-38 0.00E+00 BA-139 1.99E-02 1.40E-05 5.81E-04 0.00E+00 1.32E-05 9.67E-06 1.78E-01 0.00E+00 BA-140 1.61E+03 1.97E+00 1.04E+02 0.00E+00 6.69E-01 1.33E+00 2.48E+03 0.00E+00 LA-140 1.65E-01 8.10E-02 2.15E-02 0.00E+00 0.00E+00 0.00E+00 4.65E+03 0.00E+00 BA-141 5.35E-12 4.00E-15 1.79E-13 0.00E+00 3.71E-15 2.74E-15 1.14E-17 0.00E+00 LA-141 3.21E-03 9.87E-04 1.63E-04 0.00E+00 0.00E+00 0.00E+00 1.75E+02 0.00E+00 CE-141 7.66E-01 5.12E-01 5.88E-02 0.00E+00 2.41E-01 0.00E+00 1.46E+03 0.00E+00 BA-142 9.65E-21 9.65E-24 5.94E-22 0.00E+00 8.17E-24 6.42E-24 2.96E-32 0.00E+00 LA-142 5.57E-05 2.47E-05 6.16E-06 0.00E+00 0.00E+00 0.00E+00 7.53E-01 0.00E+00 CE-143 1.06E-01 7.74E+01 8.64E-03 0.00E+00 3.47E-02 0.00E+00 2.33E+03 0.00E+00 PR-143 7.43E-01 2.97E-01 3.70E-02 0.00E+00 1.73E-01 0.00E+00 2.45E+03 0.00E+00 CE-144 4.05E+01 1.67E+01 2.17E+00 0.00E+00 1.00E+01 0.00E+00 1.02E+04 0.00E+00 PR-144 7.17E-16 2.94E-16 3.64E-17 0.00E+00 1.68E-16 0.00E+00 7.91E-19 0.00E+00 ND-147 5.29E-01 5.75E-01 3.45E-02 0.00E+00 3.38E-01 0.00E+00 2.08E+03 0.00E+00 PM-147 6.11E+00 5.80E-01 2.36E-01 0.00E+00 1.11E+00 0.00E+00 5.51E+02 0.00E+00 PM-148m 2.39E+00 6.06E-01 4.74E-01 0.00E+00 9.18E-01 0.00E+00 3.82E+03 0.00E+00 PM-148 5.57E-01 9.06E-02 4.56E-02 0.00E+00 1.64E-01 0.00E+00 5.40E+03 0.00E+00 PM-149 1.08E-01 1.52E-02 6.22E-03 0.00E+00 2.89E-02 0.00E+00 2.23E+03 0.00E+00 PM-151 4.29E-02 7.08E-03 3.58E-03 0.00E+00 1.27E-02 0.00E+00 1.59E+03 0.00E+00 SM-151 5.08E+00 9.78E-01 2.29E-01 0.00E+00 1.07E+00 0.00E+00 3.32E+02 0.00E+00 II.4-77 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-18 (Page 4 of 4)
Teen Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 5.94E-02 4.92E-02 3.62E-03 0.00E+00 1.61E-02 0.00E+00 1.39E+03 0.00E+00 EU-152 1.43E+01 3.43E+00 3.03E+00 0.00E+00 1.60E+01 0.00E+00 1.26E+03 0.00E+00 EU-154 4.60E+01 5.94E+00 4.19E+00 0.00E+00 2.65E+01 0.00E+00 3.14E+03 0.00E+00 EU-155 1.01E+01 9.78E-01 6.05E-01 0.00E+00 3.82E+00 0.00E+00 5.61E+03 0.00E+00 EU-156 1.09E+00 8.19E-01 1.34E-01 0.00E+00 5.51E-01 0.00E+00 4.19E+03 0.00E+00 TB-160 3.75E+00 0.00E+00 4.68E-01 0.00E+00 1.48E+00 0.00E+00 2.43E+03 0.00E+00 HO-166m 2.08E+01 6.40E+00 4.63E+00 0.00E+00 9.37E+00 0.00E+00 5.82E-17 0.00E+00 W-181 8.24E-01 2.66E-01 2.78E-02 0.00E+00 0.00E+00 0.00E+00 2.26E+01 0.00E+00 W-185 3.36E+01 1.11E+01 1.17E+00 0.00E+00 0.00E+00 0.00E+00 9.56E+02 0.00E+00 W-187 6.00E+00 4.89E+00 1.71E+00 0.00E+00 0.00E+00 0.00E+00 1.32E+03 0.00E+00 NP-239 8.84E-02 8.34E-03 4.63E-03 0.00E+00 2.62E-02 0.00E+00 1.34E+03 0.00E+00 U-232 3.43E+05 0.00E+00 2.45E+04 0.00E+00 3.71E+04 0.00E+00 4.19E+03 0.00E+00 U-233 7.22E+04 0.00E+00 4.39E+03 0.00E+00 1.69E+04 0.00E+00 3.87E+03 0.00E+00 U-234 6.93E+04 0.00E+00 4.30E+03 0.00E+00 1.66E+04 0.00E+00 3.79E+03 0.00E+00 U-235 6.64E+04 0.00E+00 4.04E+03 0.00E+00 1.55E+04 0.00E+00 4.82E+03 0.00E+00 U-236 6.64E+04 0.00E+00 4.13E+03 0.00E+00 1.59E+04 0.00E+00 3.56E+03 0.00E+00 U-237 4.36E+00 0.00E+00 1.16E+00 0.00E+00 1.79E+01 0.00E+00 1.16E+03 0.00E+00 U-238 6.35E+04 0.00E+00 3.78E+03 0.00E+00 1.46E+04 0.00E+00 3.39E+03 0.00E+00 NP-237 7.74E+04 5.56E+03 3.41E+03 0.00E+00 2.52E+04 0.00E+00 4.90E+03 0.00E+00 NP-238 9.64E-01 2.58E-02 1.50E-02 0.00E+00 8.85E-02 0.00E+00 1.89E+03 0.00E+00 PU-238 3.90E+04 5.00E+03 1.06E+03 0.00E+00 4.54E+03 0.00E+00 4.50E+03 0.00E+00 PU-239 4.45E+04 5.41E+03 1.17E+03 0.00E+00 4.99E+03 0.00E+00 4.11E+03 0.00E+00 PU-240 4.45E+04 5.40E+03 1.17E+03 0.00E+00 4.98E+03 0.00E+00 4.19E+03 0.00E+00 PU-241 1.02E+03 4.89E+01 2.15E+01 0.00E+00 9.95E+01 0.00E+00 8.62E+01 0.00E+00 PU-242 4.13E+04 5.20E+03 1.13E+03 0.00E+00 4.80E+03 0.00E+00 4.03E+03 0.00E+00 PU-244 4.82E+04 5.94E+03 1.29E+03 0.00E+00 5.50E+03 0.00E+00 6.00E+03 0.00E+00 AM-241 4.65E+04 4.38E+04 3.35E+03 0.00E+00 2.51E+04 0.00E+00 4.58E+03 0.00E+00 AM-242m 4.70E+04 4.14E+04 3.38E+03 0.00E+00 2.50E+04 0.00E+00 5.76E+03 0.00E+00 AM-243 4.63E+04 4.28E+04 3.27E+03 0.00E+00 2.46E+04 0.00E+00 5.37E+03 0.00E+00 CM-242 1.71E+03 1.80E+03 1.13E+02 0.00E+00 5.16E+02 0.00E+00 4.88E+03 0.00E+00 CM-243 3.78E+04 3.51E+04 2.38E+03 0.00E+00 1.11E+04 0.00E+00 4.82E+03 0.00E+00 CM-244 2.93E+04 2.78E+04 1.86E+03 0.00E+00 8.67E+03 0.00E+00 4.66E+03 0.00E+00 CM-245 5.76E+04 5.07E+04 3.55E+03 0.00E+00 1.66E+04 0.00E+00 4.34E+03 0.00E+00 CM-246 5.72E+04 5.07E+04 3.55E+03 0.00E+00 1.65E+04 0.00E+00 4.27E+03 0.00E+00 CM-247 5.57E+04 4.99E+04 3.49E+03 0.00E+00 1.63E+04 0.00E+00 5.61E+03 0.00E+00 CM-248 4.63E+05 4.11E+05 2.88E+04 0.00E+00 1.34E+05 0.00E+00 9.02E+04 0.00E+00 CF-252 2.02E+04 0.00E+00 4.87E+02 0.00E+00 0.00E+00 0.00E+00 1.78E+04 0.00E+00 II.4-78 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-19 (Page 1 of 4)
Adult Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 4.99E+00 4.99E+00 4.99E+00 4.99E+00 4.99E+00 4.99E+00 0.00E+00 C-14 2.37E+02 4.73E+01 4.73E+01 4.73E+01 4.73E+01 4.73E+01 4.73E+01 0.00E+00 NA-22 1.45E+03 1.45E+03 1.45E+03 1.45E+03 1.45E+03 1.45E+03 1.45E+03 0.00E+00 NA-24 8.14E+01 8.14E+01 8.14E+01 8.14E+01 8.14E+01 8.14E+01 8.14E+01 0.00E+00 P-32 1.57E+04 9.76E+02 6.07E+02 0.00E+00 0.00E+00 0.00E+00 1.77E+03 0.00E+00 CA-41 1.54E+04 0.00E+00 1.67E+03 0.00E+00 0.00E+00 0.00E+00 1.53E+01 0.00E+00 SC-46 4.57E-01 8.88E-01 2.58E-01 0.00E+00 8.29E-01 0.00E+00 4.32E+03 0.00E+00 CR-51 0.00E+00 0.00E+00 2.19E-01 1.31E-01 4.82E-02 2.91E-01 5.51E+01 0.00E+00 MN-54 0.00E+00 3.80E+02 7.26E+01 0.00E+00 1.13E+02 0.00E+00 1.17E+03 0.00E+00 FE-55 2.29E+02 1.58E+02 3.69E+01 0.00E+00 0.00E+00 8.83E+01 9.08E+01 0.00E+00 MN-56 0.00E+00 3.81E-01 6.75E-02 0.00E+00 4.83E-01 0.00E+00 1.21E+01 0.00E+00 CO-57 0.00E+00 1.46E+01 2.42E+01 0.00E+00 0.00E+00 0.00E+00 3.70E+02 0.00E+00 CO-58 0.00E+00 6.18E+01 1.38E+02 0.00E+00 0.00E+00 0.00E+00 1.25E+03 0.00E+00 FE-59 3.59E+02 8.43E+02 3.23E+02 0.00E+00 0.00E+00 2.36E+02 2.81E+03 0.00E+00 CO-60 0.00E+00 1.78E+02 3.93E+02 0.00E+00 0.00E+00 0.00E+00 3.35E+03 0.00E+00 NI-59 8.13E+02 2.79E+02 1.36E+02 0.00E+00 0.00E+00 0.00E+00 5.75E+01 0.00E+00 NI-63 1.08E+04 7.51E+02 3.63E+02 0.00E+00 0.00E+00 0.00E+00 1.57E+02 0.00E+00 CU-64 0.00E+00 3.61E+00 1.69E+00 0.00E+00 9.09E+00 0.00E+00 3.07E+02 0.00E+00 NI-65 1.62E+00 2.11E-01 9.61E-02 0.00E+00 0.00E+00 0.00E+00 5.34E+00 0.00E+00 ZN-65 4.03E+02 1.28E+03 5.79E+02 0.00E+00 8.57E+02 0.00E+00 8.07E+02 0.00E+00 ZN-69m 7.74E+00 1.86E+01 1.70E+00 0.00E+00 1.12E+01 0.00E+00 1.13E+03 0.00E+00 ZN-69 1.08E-04 2.08E-04 1.44E-05 0.00E+00 1.35E-04 0.00E+00 3.12E-05 0.00E+00 SE-79 0.00E+00 2.19E+02 3.66E+01 0.00E+00 3.79E+02 0.00E+00 4.48E+01 0.00E+00 BR-82 0.00E+00 0.00E+00 1.49E+02 0.00E+00 0.00E+00 0.00E+00 1.71E+02 0.00E+00 BR-83 0.00E+00 0.00E+00 1.03E-01 0.00E+00 0.00E+00 0.00E+00 1.49E-01 0.00E+00 BR-84 0.00E+00 0.00E+00 6.64E-07 0.00E+00 0.00E+00 0.00E+00 5.21E-12 0.00E+00 BR-85 0.00E+00 0.00E+00 4.40E-77 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.73E+03 8.04E+02 0.00E+00 0.00E+00 0.00E+00 3.40E+02 0.00E+00 RB-87 0.00E+00 1.03E+03 3.57E+02 0.00E+00 0.00E+00 0.00E+00 4.80E+01 0.00E+00 RB-88 0.00E+00 3.36E-12 1.78E-12 0.00E+00 0.00E+00 0.00E+00 4.64E-23 0.00E+00 RB-89 0.00E+00 3.06E-14 2.15E-14 0.00E+00 0.00E+00 0.00E+00 1.78E-27 0.00E+00 SR-89 2.55E+04 0.00E+00 7.32E+02 0.00E+00 0.00E+00 0.00E+00 4.09E+03 0.00E+00 SR-90 7.26E+05 0.00E+00 1.46E+04 0.00E+00 0.00E+00 0.00E+00 1.82E+04 0.00E+00 Y-90 7.04E-01 0.00E+00 1.89E-02 0.00E+00 0.00E+00 0.00E+00 7.47E+03 0.00E+00 SR-91 1.97E+02 0.00E+00 7.95E+00 0.00E+00 0.00E+00 0.00E+00 9.37E+02 0.00E+00 Y-91m 3.31E-07 0.00E+00 1.28E-08 0.00E+00 0.00E+00 0.00E+00 9.71E-07 0.00E+00 Y-91 1.17E+01 0.00E+00 3.12E-01 0.00E+00 0.00E+00 0.00E+00 6.43E+03 0.00E+00 II.4-79 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-19 (Page 2 of 4)
Adult Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 8.32E+00 0.00E+00 3.60E-01 0.00E+00 0.00E+00 0.00E+00 1.65E+02 0.00E+00 Y-92 6.72E-03 0.00E+00 1.96E-04 0.00E+00 0.00E+00 0.00E+00 1.18E+02 0.00E+00 Y-93 9.80E-02 0.00E+00 2.71E-03 0.00E+00 0.00E+00 0.00E+00 3.11E+03 0.00E+00 NB-93m 2.12E+00 6.93E-01 1.71E-01 0.00E+00 7.97E-01 0.00E+00 3.20E+02 0.00E+00 NB-95 5.13E-01 2.85E-01 1.53E-01 0.00E+00 2.82E-01 0.00E+00 1.73E+03 0.00E+00 NB-97 4.29E-06 1.08E-06 3.96E-07 0.00E+00 1.27E-06 0.00E+00 4.00E-03 0.00E+00 ZR-93 3.48E+00 1.95E-01 9.08E-02 0.00E+00 7.39E-01 0.00E+00 2.03E+02 0.00E+00 ZR-95 2.52E+00 8.08E-01 5.47E-01 0.00E+00 1.27E+00 0.00E+00 2.56E+03 0.00E+00 ZR-97 8.56E-02 1.73E-02 7.90E-03 0.00E+00 2.61E-02 0.00E+00 5.35E+03 0.00E+00 MO-93 0.00E+00 6.26E+02 1.69E+01 0.00E+00 1.78E+02 0.00E+00 1.02E+02 0.00E+00 MO-99 0.00E+00 3.17E+02 6.02E+01 0.00E+00 7.17E+02 0.00E+00 7.34E+02 0.00E+00 TC-99 1.04E+01 1.55E+01 4.18E+00 0.00E+00 1.95E+02 1.32E+00 5.07E+02 0.00E+00 TC-99m 5.17E-03 1.46E-02 1.86E-01 0.00E+00 2.22E-01 7.16E-03 8.64E+00 0.00E+00 TC-101 1.15E-17 1.66E-17 1.63E-16 0.00E+00 2.99E-16 8.50E-18 5.00E-29 0.00E+00 RU-103 1.53E+01 0.00E+00 6.58E+00 0.00E+00 5.83E+01 0.00E+00 1.78E+03 0.00E+00 RU-105 1.97E-01 0.00E+00 7.78E-02 0.00E+00 2.55E+00 0.00E+00 1.21E+02 0.00E+00 RU-106 2.29E+02 0.00E+00 2.90E+01 0.00E+00 4.42E+02 0.00E+00 1.48E+04 0.00E+00 RH-105 7.97E+00 5.83E+00 3.84E+00 0.00E+00 2.48E+01 0.00E+00 9.29E+02 0.00E+00 PD-107 0.00E+00 1.23E+01 7.83E-01 0.00E+00 1.10E+02 0.00E+00 7.59E+01 0.00E+00 PD-109 0.00E+00 7.95E+00 1.79E+00 0.00E+00 4.54E+01 0.00E+00 8.80E+02 0.00E+00 AG-110m 1.33E+01 1.23E+01 7.31E+00 0.00E+00 2.42E+01 0.00E+00 5.03E+03 0.00E+00 AG-111 4.62E+00 1.93E+00 9.63E-01 0.00E+00 6.24E+00 0.00E+00 3.55E+03 0.00E+00 CD-113m 0.00E+00 2.65E+02 8.50E+00 0.00E+00 2.92E+02 0.00E+00 2.13E+03 0.00E+00 CD-115m 0.00E+00 1.52E+02 4.85E+00 0.00E+00 1.21E+02 0.00E+00 6.40E+03 0.00E+00 SN-123 2.58E+03 4.28E+01 6.31E+01 3.64E+01 0.00E+00 0.00E+00 5.26E+03 0.00E+00 SN-125 6.70E+02 1.35E+01 3.04E+01 1.12E+01 0.00E+00 0.00E+00 8.36E+03 0.00E+00 SN-126 7.04E+03 1.39E+02 2.00E+02 4.10E+01 0.00E+00 0.00E+00 2.03E+03 0.00E+00 SB-124 2.32E+02 4.38E+00 9.20E+01 5.63E-01 0.00E+00 1.81E+02 6.59E+03 0.00E+00 SB-125 1.49E+02 1.67E+00 3.55E+01 1.52E-01 0.00E+00 1.15E+02 1.64E+03 0.00E+00 SB-126 9.32E+01 1.90E+00 3.36E+01 5.70E-01 0.00E+00 5.71E+01 7.62E+03 0.00E+00 SB-127 1.96E+01 4.30E-01 7.54E+00 2.36E-01 0.00E+00 1.17E+01 4.49E+03 0.00E+00 TE-125m 2.22E+02 8.04E+01 2.97E+01 6.68E+01 9.03E+02 0.00E+00 8.86E+02 0.00E+00 TE-127m 5.62E+02 2.01E+02 6.85E+01 1.44E+02 2.28E+03 0.00E+00 1.89E+03 0.00E+00 TE-127 3.77E+00 1.35E+00 8.15E-01 2.79E+00 1.53E+01 0.00E+00 2.97E+02 0.00E+00 TE-129m 9.48E+02 3.54E+02 1.50E+02 3.26E+02 3.96E+03 0.00E+00 4.78E+03 0.00E+00 TE-129 2.01E-03 7.56E-04 4.90E-04 1.54E-03 8.46E-03 0.00E+00 1.52E-03 0.00E+00 TE-133m 4.71E-04 2.75E-04 2.65E-04 3.99E-04 2.72E-03 0.00E+00 9.44E-05 0.00E+00 II.4-80 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-19 (Page 3 of 4)
Adult Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 1.76E-05 1.15E-05 7.07E-06 1.54E-05 1.12E-04 0.00E+00 1.95E-08 0.00E+00 I-129 2.73E+02 2.34E+02 7.68E+02 6.03E+05 5.03E+02 0.00E+00 3.70E+01 0.00E+00 I-130 3.21E+01 9.48E+01 3.74E+01 8.04E+03 1.48E+02 0.00E+00 8.16E+01 0.00E+00 I-131 3.32E+02 4.75E+02 2.72E+02 1.56E+05 8.14E+02 0.00E+00 1.25E+02 0.00E+00 TE-131m 1.09E+02 5.34E+01 4.45E+01 8.46E+01 5.41E+02 0.00E+00 5.31E+03 0.00E+00 TE-131 3.51E-09 1.47E-09 1.11E-09 2.89E-09 1.54E-08 0.00E+00 4.97E-10 0.00E+00 I-132 4.55E-01 1.22E+00 4.26E-01 4.26E+01 1.94E+00 0.00E+00 2.28E-01 0.00E+00 TE-132 1.89E+02 1.22E+02 1.15E+02 1.35E+02 1.18E+03 0.00E+00 5.78E+03 0.00E+00 I-133 7.93E+01 1.38E+02 4.21E+01 2.03E+04 2.41E+02 0.00E+00 1.24E+02 0.00E+00 CS-134m 1.01E-01 2.12E-01 1.08E-01 0.00E+00 1.15E-01 1.81E-02 7.48E-02 0.00E+00 CS-134 5.18E+03 1.23E+04 1.01E+04 0.00E+00 3.99E+03 1.32E+03 2.16E+02 0.00E+00 I-134 6.69E-04 1.82E-03 6.50E-04 3.15E-02 2.89E-03 0.00E+00 1.58E-06 0.00E+00 I-135 1.05E+01 2.75E+01 1.01E+01 1.81E+03 4.40E+01 0.00E+00 3.10E+01 0.00E+00 CS-135 1.63E+03 1.50E+03 6.66E+02 0.00E+00 5.68E+02 1.70E+02 3.51E+01 0.00E+00 CS-136 5.28E+02 2.09E+03 1.50E+03 0.00E+00 1.16E+03 1.59E+02 2.37E+02 0.00E+00 CS-137 6.64E+03 9.08E+03 5.95E+03 0.00E+00 3.08E+03 1.02E+03 1.76E+02 0.00E+00 CS-138 8.54E-07 1.69E-06 8.36E-07 0.00E+00 1.24E-06 1.22E-07 7.20E-12 0.00E+00 CS-139 2.49E-23 3.71E-23 1.35E-23 0.00E+00 2.97E-23 2.70E-24 8.03E-46 0.00E+00 BA-139 1.99E-02 1.42E-05 5.83E-04 0.00E+00 1.33E-05 8.05E-06 3.53E-02 0.00E+00 BA-140 1.65E+03 2.07E+00 1.08E+02 0.00E+00 7.03E-01 1.18E+00 3.39E+03 0.00E+00 LA-140 1.69E-01 8.54E-02 2.26E-02 0.00E+00 0.00E+00 0.00E+00 6.27E+03 0.00E+00 BA-141 5.38E-12 4.06E-15 1.82E-13 0.00E+00 3.78E-15 2.31E-15 2.53E-21 0.00E+00 LA-141 3.22E-03 9.99E-04 1.63E-04 0.00E+00 0.00E+00 0.00E+00 1.19E+02 0.00E+00 CE-141 7.72E-01 5.22E-01 5.92E-02 0.00E+00 2.42E-01 0.00E+00 2.00E+03 0.00E+00 BA-142 9.84E-21 1.01E-23 6.19E-22 0.00E+00 8.55E-24 5.73E-24 1.39E-38 0.00E+00 LA-142 5.70E-05 2.59E-05 6.46E-06 0.00E+00 0.00E+00 0.00E+00 1.89E-01 0.00E+00 CE-143 1.07E-01 7.90E+01 8.74E-03 0.00E+00 3.48E-02 0.00E+00 2.95E+03 0.00E+00 PR-143 7.47E-01 3.00E-01 3.70E-02 0.00E+00 1.73E-01 0.00E+00 3.27E+03 0.00E+00 CE-144 4.06E+01 1.70E+01 2.18E+00 0.00E+00 1.01E+01 0.00E+00 1.37E+04 0.00E+00 PR-144 7.19E-16 2.98E-16 3.65E-17 0.00E+00 1.68E-16 0.00E+00 1.03E-22 0.00E+00 ND-147 5.08E-01 5.87E-01 3.51E-02 0.00E+00 3.43E-01 0.00E+00 2.82E+03 0.00E+00 PM-147 6.28E+00 5.91E-01 2.39E-01 0.00E+00 1.12E+00 0.00E+00 7.44E+02 0.00E+00 PM-148m 2.54E+00 6.57E-01 5.02E-01 0.00E+00 9.92E-01 0.00E+00 5.57E+03 0.00E+00 PM-148 5.60E-01 9.30E-02 4.68E-02 0.00E+00 1.76E-01 0.00E+00 7.30E+03 0.00E+00 PM-149 1.08E-01 1.53E-02 6.26E-03 0.00E+00 2.89E-02 0.00E+00 2.87E+03 0.00E+00 PM-151 4.33E-02 7.27E-03 3.67E-03 0.00E+00 1.30E-02 0.00E+00 2.00E+03 0.00E+00 SM-151 5.75E+00 9.92E-01 2.37E-01 0.00E+00 1.11E+00 0.00E+00 4.37E+02 0.00E+00 II.4-81 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-19 (Page 4 of 4)
Adult Drinking Water Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 5.98E-02 4.99E-02 3.64E-03 0.00E+00 1.61E-02 0.00E+00 1.78E+03 0.00E+00 EU-152 1.62E+01 3.70E+00 3.25E+00 0.00E+00 2.29E+01 0.00E+00 2.13E+03 0.00E+00 EU-154 5.12E+01 6.30E+00 4.48E+00 0.00E+00 3.02E+01 0.00E+00 4.57E+03 0.00E+00 EU-155 7.17E+00 1.02E+00 6.56E-01 0.00E+00 4.69E+00 0.00E+00 8.00E+02 0.00E+00 EU-156 1.12E+00 8.63E-01 1.39E-01 0.00E+00 5.77E-01 0.00E+00 5.91E+03 0.00E+00 TB-160 3.90E+00 0.00E+00 4.86E-01 0.00E+00 1.61E+00 0.00E+00 2.12E+03 0.00E+00 HO-166m 2.25E+01 7.02E+00 5.33E+00 0.00E+00 1.05E+01 0.00E+00 8.33E-17 0.00E+00 W-181 8.23E-01 2.68E-01 2.88E-02 0.00E+00 0.00E+00 0.00E+00 3.06E+01 0.00E+00 W-185 3.36E+01 1.12E+01 1.18E+00 0.00E+00 0.00E+00 0.00E+00 1.29E+03 0.00E+00 W-187 6.05E+00 5.06E+00 1.77E+00 0.00E+00 0.00E+00 0.00E+00 1.66E+03 0.00E+00 NP-239 8.56E-02 8.42E-03 4.64E-03 0.00E+00 2.63E-02 0.00E+00 1.73E+03 0.00E+00 U-232 3.44E+05 0.00E+00 2.46E+04 0.00E+00 3.72E+04 0.00E+00 5.65E+03 0.00E+00 U-233 7.26E+04 0.00E+00 4.40E+03 0.00E+00 1.69E+04 0.00E+00 5.23E+03 0.00E+00 U-234 6.97E+04 0.00E+00 4.31E+03 0.00E+00 1.66E+04 0.00E+00 5.12E+03 0.00E+00 U-235 6.68E+04 0.00E+00 4.05E+03 0.00E+00 1.56E+04 0.00E+00 6.51E+03 0.00E+00 U-236 6.68E+04 0.00E+00 4.13E+03 0.00E+00 1.59E+04 0.00E+00 4.80E+03 0.00E+00 U-237 4.37E+00 0.00E+00 1.16E+00 0.00E+00 1.80E+01 0.00E+00 1.54E+03 0.00E+00 U-238 6.39E+04 0.00E+00 3.78E+03 0.00E+00 1.46E+04 0.00E+00 4.58E+03 0.00E+00 NP-237 1.05E+05 7.47E+03 4.62E+03 0.00E+00 3.43E+04 0.00E+00 6.62E+03 0.00E+00 NP-238 9.69E-01 2.61E-02 1.51E-02 0.00E+00 8.84E-02 0.00E+00 2.43E+03 0.00E+00 PU-238 5.25E+04 6.65E+03 1.42E+03 0.00E+00 6.10E+03 0.00E+00 6.08E+03 0.00E+00 PU-239 6.04E+04 7.26E+03 1.59E+03 0.00E+00 6.76E+03 0.00E+00 5.55E+03 0.00E+00 PU-240 6.03E+04 7.25E+03 1.59E+03 0.00E+00 6.75E+03 0.00E+00 5.65E+03 0.00E+00 PU-241 1.31E+03 6.21E+01 2.77E+01 0.00E+00 1.27E+02 0.00E+00 1.17E+02 0.00E+00 PU-242 5.60E+04 6.99E+03 1.53E+03 0.00E+00 6.51E+03 0.00E+00 5.44E+03 0.00E+00 PU-244 6.53E+04 8.01E+03 1.76E+03 0.00E+00 7.46E+03 0.00E+00 8.11E+03 0.00E+00 AM-241 6.29E+04 5.87E+04 4.51E+03 0.00E+00 3.39E+04 0.00E+00 6.18E+03 0.00E+00 AM-242m 6.34E+04 5.52E+04 4.52E+03 0.00E+00 3.37E+04 0.00E+00 7.78E+03 0.00E+00 AM-243 6.28E+04 5.75E+04 4.42E+03 0.00E+00 3.33E+04 0.00E+00 7.25E+03 0.00E+00 CM-242 1.71E+03 1.82E+03 1.14E+02 0.00E+00 5.17E+02 0.00E+00 6.59E+03 0.00E+00 CM-243 4.99E+04 4.57E+04 3.12E+03 0.00E+00 1.46E+04 0.00E+00 6.51E+03 0.00E+00 CM-244 3.80E+04 3.56E+04 2.39E+03 0.00E+00 1.12E+04 0.00E+00 6.29E+03 0.00E+00 CM-245 7.82E+04 6.81E+04 4.80E+03 0.00E+00 2.24E+04 0.00E+00 5.87E+03 0.00E+00 CM-246 7.75E+04 6.80E+04 4.79E+03 0.00E+00 2.23E+04 0.00E+00 5.76E+03 0.00E+00 CM-247 7.56E+04 6.70E+04 4.73E+03 0.00E+00 2.20E+04 0.00E+00 7.58E+03 0.00E+00 CM-248 6.28E+05 5.53E+05 3.89E+04 0.00E+00 1.82E+05 0.00E+00 1.23E+05 0.00E+00 CF-252 2.17E+04 0.00E+00 5.24E+02 0.00E+00 0.00E+00 0.00E+00 2.40E+04 0.00E+00 II.4-82 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-20 (Page 1 of 4)
Infant Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C-14 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NA-22 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NA-24 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 P-32 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CA-41 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SC-46 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CR-51 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MN-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 FE-55 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MN-56 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-57 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-58 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 FE-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-60 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-63 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CU-64 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-65 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-65 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-69m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-69 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SE-79 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-82 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-87 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-90 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-90 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-91 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-91m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-91 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-83 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-20 (Page 2 of 4)
Infant Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-92 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-93m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-95 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-97 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-95 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-97 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MO-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MO-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-99m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-101 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-103 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-105 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-106 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RH-105 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PD-107 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PD-109 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AG-110m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AG-111 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CD-113m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CD-115m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-123 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-125 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-126 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-124 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-125 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-126 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-127 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-125m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-127m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-127 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-129m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-133m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-84 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-20 (Page 3 of 4)
Infant Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-130 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-131m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-132 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-132 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-133 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-134m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-135 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-135 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-136 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-137 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-138 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-143 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PR-143 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PR-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND-147 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-147 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-148m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-148 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-149 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SM-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-85 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-20 (Page 4 of 4)
Infant Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-152 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-155 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-156 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TB-160 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 HO-166m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-181 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-185 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-187 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-239 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-232 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-233 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-234 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-235 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-236 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-237 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-237 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-239 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-240 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-241 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-242 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-244 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-241 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-242m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-243 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-242 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-243 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-244 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-245 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-246 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-247 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-248 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CF-252 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-86 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-21 (Page 1 of 4)
Child Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 8.22E-02 8.22E-02 8.22E-02 8.22E-02 8.22E-02 8.22E-02 0.00E+00 C-14 4.38E+04 8.77E+03 8.77E+03 8.77E+03 8.77E+03 8.77E+03 8.77E+03 0.00E+00 NA-22 4.63E+03 4.63E+03 4.63E+03 4.63E+03 4.63E+03 4.63E+03 4.63E+03 0.00E+00 NA-24 1.51E+02 1.51E+02 1.51E+02 1.51E+02 1.51E+02 1.51E+02 1.51E+02 0.00E+00 P-32 1.86E+06 8.69E+04 7.16E+04 0.00E+00 0.00E+00 0.00E+00 5.13E+04 0.00E+00 CA-41 1.09E+04 0.00E+00 1.19E+03 0.00E+00 0.00E+00 0.00E+00 5.99E+00 0.00E+00 SC-46 3.08E-02 4.22E-02 1.62E-02 0.00E+00 3.73E-02 0.00E+00 6.17E+01 0.00E+00 CR-51 0.00E+00 0.00E+00 1.37E+00 7.59E-01 2.07E-01 1.39E+00 7.25E+01 0.00E+00 MN-54 0.00E+00 3.36E+03 8.96E+02 0.00E+00 9.43E+02 0.00E+00 2.82E+03 0.00E+00 FE-55 9.05E+02 4.80E+02 1.49E+02 0.00E+00 0.00E+00 2.72E+02 8.89E+01 0.00E+00 MN-56 0.00E+00 1.66E-01 3.75E-02 0.00E+00 2.01E-01 0.00E+00 2.41E+01 0.00E+00 CO-57 0.00E+00 1.94E+01 3.92E+01 0.00E+00 0.00E+00 0.00E+00 1.59E+02 0.00E+00 CO-58 0.00E+00 7.02E+01 2.15E+02 0.00E+00 0.00E+00 0.00E+00 4.09E+02 0.00E+00 FE-59 1.28E+03 2.07E+03 1.03E+03 0.00E+00 0.00E+00 6.00E+02 2.16E+03 0.00E+00 CO-60 0.00E+00 2.08E+02 6.14E+02 0.00E+00 0.00E+00 0.00E+00 1.15E+03 0.00E+00 NI-59 3.17E+03 8.43E+02 5.37E+02 0.00E+00 0.00E+00 0.00E+00 5.59E+01 0.00E+00 NI-63 4.24E+04 2.27E+03 1.44E+03 0.00E+00 0.00E+00 0.00E+00 1.53E+02 0.00E+00 CU-64 0.00E+00 2.60E+00 1.57E+00 0.00E+00 6.29E+00 0.00E+00 1.22E+02 0.00E+00 NI-65 2.38E-01 2.24E-02 1.31E-02 0.00E+00 0.00E+00 0.00E+00 2.74E+00 0.00E+00 ZN-65 2.15E+04 5.73E+04 3.57E+04 0.00E+00 3.61E+04 0.00E+00 1.01E+04 0.00E+00 ZN-69m 3.34E+02 5.69E+02 6.72E+01 0.00E+00 3.30E+02 0.00E+00 1.85E+04 0.00E+00 ZN-69 1.10E-06 1.59E-06 1.47E-07 0.00E+00 9.67E-07 0.00E+00 1.00E-04 0.00E+00 SE-79 0.00E+00 1.13E+03 2.50E+02 0.00E+00 1.83E+03 0.00E+00 7.40E+01 0.00E+00 BR-82 0.00E+00 0.00E+00 1.56E+03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 5.37E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 1.53E-12 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.84E-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.02E+05 6.25E+04 0.00E+00 0.00E+00 0.00E+00 6.54E+03 0.00E+00 RB-87 0.00E+00 6.22E+04 2.88E+04 0.00E+00 0.00E+00 0.00E+00 9.33E+02 0.00E+00 RB-88 0.00E+00 1.33E-22 9.22E-23 0.00E+00 0.00E+00 0.00E+00 6.51E-24 0.00E+00 RB-89 0.00E+00 1.55E-26 1.38E-26 0.00E+00 0.00E+00 0.00E+00 1.35E-28 0.00E+00 SR-89 3.08E+04 0.00E+00 8.79E+02 0.00E+00 0.00E+00 0.00E+00 1.19E+03 0.00E+00 SR-90 6.05E+05 0.00E+00 1.22E+04 0.00E+00 0.00E+00 0.00E+00 5.41E+03 0.00E+00 Y-90 6.24E-01 0.00E+00 1.67E-02 0.00E+00 0.00E+00 0.00E+00 1.78E+03 0.00E+00 SR-91 9.84E+01 0.00E+00 3.72E+00 0.00E+00 0.00E+00 0.00E+00 2.17E+02 0.00E+00 Y-91m 1.43E-11 0.00E+00 5.21E-13 0.00E+00 0.00E+00 0.00E+00 2.81E-08 0.00E+00 Y-91 1.17E+01 0.00E+00 3.13E-01 0.00E+00 0.00E+00 0.00E+00 1.56E+03 0.00E+00 II.4-87 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-21 (Page 2 of 4)
Child Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 4.60E-01 0.00E+00 1.85E-02 0.00E+00 0.00E+00 0.00E+00 8.72E+00 0.00E+00 Y-92 6.45E-04 0.00E+00 1.85E-05 0.00E+00 0.00E+00 0.00E+00 1.86E+01 0.00E+00 Y-93 4.32E-02 0.00E+00 1.19E-03 0.00E+00 0.00E+00 0.00E+00 6.45E+02 0.00E+00 NB-93m 2.48E+03 6.19E+02 2.03E+02 0.00E+00 6.69E+02 0.00E+00 9.33E+04 0.00E+00 NB-95 5.21E+02 2.03E+02 1.45E+02 0.00E+00 1.91E+02 0.00E+00 3.75E+05 0.00E+00 NB-97 4.99E-06 9.01E-07 4.20E-07 0.00E+00 9.99E-07 0.00E+00 2.78E-01 0.00E+00 ZR-93 4.34E-01 1.62E-01 1.16E-01 0.00E+00 6.29E-01 0.00E+00 6.16E+01 0.00E+00 ZR-95 2.98E-01 6.56E-02 5.84E-02 0.00E+00 9.39E-02 0.00E+00 6.84E+01 0.00E+00 ZR-97 6.79E-03 9.81E-04 5.79E-04 0.00E+00 1.41E-03 0.00E+00 1.49E+02 0.00E+00 MO-93 0.00E+00 1.90E+02 6.81E+00 0.00E+00 5.00E+01 0.00E+00 9.61E+00 0.00E+00 MO-99 0.00E+00 8.14E+01 2.01E+01 0.00E+00 1.74E+02 0.00E+00 6.73E+01 0.00E+00 TC-99 6.32E+00 7.04E+00 2.53E+00 0.00E+00 8.29E+01 6.23E-01 7.38E+01 0.00E+00 TC-99m 6.88E-04 1.35E-03 2.24E-02 0.00E+00 1.96E-02 6.85E-04 7.68E-01 0.00E+00 TC-101 3.76E-33 3.93E-33 4.99E-32 0.00E+00 6.71E-32 2.08E-33 1.25E-32 0.00E+00 RU-103 5.66E+00 0.00E+00 2.17E+00 0.00E+00 1.42E+01 0.00E+00 1.46E+02 0.00E+00 RU-105 1.20E-02 0.00E+00 4.35E-03 0.00E+00 1.05E-01 0.00E+00 7.82E+00 0.00E+00 RU-106 9.20E+01 0.00E+00 1.15E+01 0.00E+00 1.24E+02 0.00E+00 1.43E+03 0.00E+00 RH-105 2.53E+00 1.36E+00 1.16E+00 0.00E+00 5.41E+00 0.00E+00 8.41E+01 0.00E+00 PD-107 0.00E+00 3.72E+00 3.16E-01 0.00E+00 3.11E+01 0.00E+00 7.38E+00 0.00E+00 PD-109 0.00E+00 1.30E+00 3.89E-01 0.00E+00 6.95E+00 0.00E+00 7.66E+01 0.00E+00 AG-110m 9.74E-01 6.58E-01 5.26E-01 0.00E+00 1.22E+00 0.00E+00 7.82E+01 0.00E+00 AG-111 4.09E-01 1.28E-01 8.45E-02 0.00E+00 3.86E-01 0.00E+00 7.84E+01 0.00E+00 CD-113m 0.00E+00 1.61E+03 6.84E+01 0.00E+00 1.65E+03 0.00E+00 4.14E+03 0.00E+00 CD-115m 0.00E+00 9.14E+02 3.89E+01 0.00E+00 6.79E+02 0.00E+00 1.24E+04 0.00E+00 SN-123 3.13E+05 3.88E+03 7.62E+03 4.11E+03 0.00E+00 0.00E+00 1.53E+05 0.00E+00 SN-125 7.81E+04 1.18E+03 3.50E+03 1.22E+03 0.00E+00 0.00E+00 2.42E+05 0.00E+00 SN-126 7.87E+05 9.81E+03 2.24E+04 2.69E+03 0.00E+00 0.00E+00 5.91E+04 0.00E+00 SB-124 8.64E+00 1.12E-01 3.03E+00 1.91E-02 0.00E+00 4.80E+00 5.40E+01 0.00E+00 SB-125 5.64E+00 4.34E-02 1.18E+00 5.22E-03 0.00E+00 3.14E+00 1.35E+01 0.00E+00 SB-126 3.28E+00 5.01E-02 1.18E+00 1.92E-02 0.00E+00 1.56E+00 6.61E+01 0.00E+00 SB-127 6.97E-01 1.08E-02 2.42E-01 7.76E-03 0.00E+00 3.03E-01 3.93E+01 0.00E+00 TE-125m 3.55E+03 9.62E+02 4.73E+02 9.96E+02 0.00E+00 0.00E+00 3.42E+03 0.00E+00 TE-127m 9.05E+03 2.44E+03 1.07E+03 2.16E+03 2.58E+04 0.00E+00 7.33E+03 0.00E+00 TE-127 2.50E+01 6.75E+00 5.37E+00 1.73E+01 7.13E+01 0.00E+00 9.78E+02 0.00E+00 TE-129m 1.50E+04 4.20E+03 2.33E+03 4.85E+03 4.41E+04 0.00E+00 1.83E+04 0.00E+00 TE-129 2.50E-05 6.97E-06 5.92E-06 1.78E-05 7.30E-05 0.00E+00 1.55E-03 0.00E+00 TE-133m 8.82E-07 3.57E-07 4.42E-07 6.84E-07 3.39E-06 0.00E+00 2.72E-05 0.00E+00 II.4-88 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-21 (Page 3 of 4)
Child Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 1.73E-09 7.79E-10 1.04E-09 1.37E-09 7.21E-09 0.00E+00 7.91E-09 0.00E+00 I-129 1.64E+02 1.01E+02 9.00E+01 6.59E+04 1.70E+02 0.00E+00 5.07E+00 0.00E+00 I-130 8.98E+00 1.81E+01 9.35E+00 2.00E+03 2.71E+01 0.00E+00 8.49E+00 0.00E+00 I-131 1.86E+02 1.88E+02 1.07E+02 6.20E+04 3.08E+02 0.00E+00 1.67E+01 0.00E+00 TE-131m 1.30E+03 4.51E+02 4.80E+02 9.27E+02 4.36E+03 0.00E+00 1.83E+04 0.00E+00 TE-131 1.20E-16 3.65E-17 3.56E-17 9.16E-17 3.62E-16 0.00E+00 6.29E-16 0.00E+00 I-132 6.83E-03 1.25E-02 5.77E-03 5.82E-01 1.92E-02 0.00E+00 1.48E-02 0.00E+00 TE-132 2.57E+03 1.14E+03 1.38E+03 1.66E+03 1.06E+04 0.00E+00 1.15E+04 0.00E+00 I-133 3.14E+01 3.89E+01 1.47E+01 7.22E+03 6.48E+01 0.00E+00 1.57E+01 0.00E+00 CS-134m 4.29E-01 6.35E-01 4.15E-01 0.00E+00 3.35E-01 5.54E-02 8.03E-01 0.00E+00 CS-134 3.68E+05 6.04E+05 1.27E+05 0.00E+00 1.87E+05 6.72E+04 3.26E+03 0.00E+00 I-134 2.84E-08 5.28E-08 2.43E-08 1.21E-06 8.07E-08 0.00E+00 3.50E-08 0.00E+00 I-135 1.67E+00 3.00E+00 1.42E+00 2.66E+02 4.61E+00 0.00E+00 2.29E+00 0.00E+00 CS-135 1.31E+05 9.11E+04 9.34E+03 0.00E+00 3.21E+04 1.07E+04 6.82E+02 0.00E+00 CS-136 3.51E+04 9.65E+04 6.25E+04 0.00E+00 5.14E+04 7.67E+03 3.39E+03 0.00E+00 CS-137 5.15E+05 4.93E+05 7.28E+04 0.00E+00 1.61E+05 5.78E+04 3.09E+03 0.00E+00 CS-138 1.24E-11 1.72E-11 1.09E-11 0.00E+00 1.21E-11 1.30E-12 7.93E-12 0.00E+00 CS-139 1.75E-44 1.95E-44 9.35E-45 0.00E+00 1.46E-44 1.47E-45 1.75E-48 0.00E+00 BA-139 7.93E-06 4.23E-09 2.30E-07 0.00E+00 3.69E-09 2.49E-09 4.58E-04 0.00E+00 BA-140 2.48E+02 2.17E-01 1.45E+01 0.00E+00 7.07E-02 1.30E-01 1.26E+02 0.00E+00 LA-140 1.32E-01 4.60E-02 1.55E-02 0.00E+00 0.00E+00 0.00E+00 1.28E+03 0.00E+00 BA-141 1.18E-24 6.62E-28 3.85E-26 0.00E+00 5.73E-28 3.89E-27 6.74E-25 0.00E+00 LA-141 3.93E-04 9.16E-05 1.99E-05 0.00E+00 0.00E+00 0.00E+00 2.04E+01 0.00E+00 CE-141 3.06E-02 1.53E-02 2.27E-03 0.00E+00 6.69E-03 0.00E+00 1.90E+01 0.00E+00 BA-142 8.46E-42 6.09E-45 4.72E-43 0.00E+00 4.93E-45 3.58E-45 1.10E-43 0.00E+00 LA-142 2.95E-07 9.40E-08 2.94E-08 0.00E+00 0.00E+00 0.00E+00 1.86E-02 0.00E+00 CE-143 3.33E-03 1.80E+00 2.61E-04 0.00E+00 7.57E-04 0.00E+00 2.64E+01 0.00E+00 PR-143 7.35E-01 2.21E-01 3.65E-02 0.00E+00 1.20E-01 0.00E+00 7.93E+02 0.00E+00 CE-144 1.63E+00 5.12E-01 8.72E-02 0.00E+00 2.84E-01 0.00E+00 1.34E+02 0.00E+00 PR-144 2.08E-28 6.45E-29 1.05E-29 0.00E+00 3.41E-29 0.00E+00 1.39E-25 0.00E+00 ND-147 5.16E-01 4.18E-01 3.24E-02 0.00E+00 2.29E-01 0.00E+00 6.62E+02 0.00E+00 PM-147 6.26E+00 4.47E-01 2.40E-01 0.00E+00 7.89E-01 0.00E+00 1.81E+02 0.00E+00 PM-148m 1.99E+00 3.97E-01 3.97E-01 0.00E+00 5.89E-01 0.00E+00 1.12E+03 0.00E+00 PM-148 5.23E-01 6.28E-02 4.07E-02 0.00E+00 1.07E-01 0.00E+00 1.68E+03 0.00E+00 PM-149 9.34E-02 9.93E-03 5.38E-03 0.00E+00 1.76E-02 0.00E+00 6.78E+02 0.00E+00 PM-151 3.20E-02 3.89E-03 2.53E-03 0.00E+00 6.60E-03 0.00E+00 4.42E+02 0.00E+00 SM-151 5.04E+00 7.50E-01 2.36E-01 0.00E+00 7.76E-01 0.00E+00 1.09E+02 0.00E+00 II.4-89 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-21 (Page 4 of 4)
Child Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 5.03E-02 3.13E-02 3.02E-03 0.00E+00 9.53E-03 0.00E+00 4.16E+02 0.00E+00 EU-152 1.21E+01 2.21E+00 2.62E+00 0.00E+00 9.31E+00 0.00E+00 3.62E+02 0.00E+00 EU-154 4.53E+01 4.08E+00 3.72E+00 0.00E+00 1.79E+01 0.00E+00 9.47E+02 0.00E+00 EU-155 9.49E+00 6.83E-01 5.35E-01 0.00E+00 2.56E+00 0.00E+00 1.71E+03 0.00E+00 EU-156 1.06E+00 5.66E-01 1.17E-01 0.00E+00 3.65E-01 0.00E+00 1.28E+03 0.00E+00 TB-160 3.24E+00 0.00E+00 4.02E-01 0.00E+00 9.63E-01 0.00E+00 7.18E+02 0.00E+00 HO-166m 2.13E+01 4.45E+00 3.76E+00 0.00E+00 6.34E+00 0.00E+00 1.97E-17 0.00E+00 W-181 3.98E+01 9.77E+00 1.34E+00 0.00E+00 0.00E+00 0.00E+00 3.56E+02 0.00E+00 W-185 1.62E+03 4.05E+02 5.67E+01 0.00E+00 0.00E+00 0.00E+00 1.51E+04 0.00E+00 W-187 2.02E+02 1.19E+02 5.36E+01 0.00E+00 0.00E+00 0.00E+00 1.68E+04 0.00E+00 NP-239 3.08E-02 2.21E-03 1.56E-03 0.00E+00 6.40E-03 0.00E+00 1.64E+02 0.00E+00 U-232 2.77E+04 0.00E+00 1.98E+03 0.00E+00 2.11E+03 0.00E+00 1.10E+02 0.00E+00 U-233 5.86E+03 0.00E+00 3.54E+02 0.00E+00 9.61E+02 0.00E+00 1.02E+02 0.00E+00 U-234 5.62E+03 0.00E+00 3.48E+02 0.00E+00 9.42E+02 0.00E+00 9.96E+01 0.00E+00 U-235 5.39E+03 0.00E+00 3.26E+02 0.00E+00 8.84E+02 0.00E+00 1.27E+02 0.00E+00 U-236 5.39E+03 0.00E+00 3.34E+02 0.00E+00 9.03E+02 0.00E+00 9.33E+01 0.00E+00 U-237 3.35E-01 0.00E+00 8.91E-02 0.00E+00 9.68E-01 0.00E+00 2.96E+01 0.00E+00 U-238 5.15E+03 0.00E+00 3.06E+02 0.00E+00 8.25E+02 0.00E+00 8.92E+01 0.00E+00 NP-237 1.76E+04 1.16E+03 7.71E+02 0.00E+00 4.77E+03 0.00E+00 6.43E+02 0.00E+00 NP-238 3.31E-01 6.70E-03 5.16E-03 0.00E+00 2.13E-02 0.00E+00 2.29E+02 0.00E+00 PU-238 3.28E+03 3.80E+02 8.71E+01 0.00E+00 3.17E+02 0.00E+00 2.07E+02 0.00E+00 PU-239 3.56E+03 3.80E+02 9.13E+01 0.00E+00 3.36E+02 0.00E+00 1.89E+02 0.00E+00 PU-240 3.53E+03 3.94E+02 9.13E+01 0.00E+00 3.36E+02 0.00E+00 1.92E+02 0.00E+00 PU-241 1.07E+02 4.36E+00 2.22E+00 0.00E+00 8.16E+00 0.00E+00 3.97E+00 0.00E+00 PU-242 3.28E+03 3.80E+02 8.79E+01 0.00E+00 3.23E+02 0.00E+00 1.85E+02 0.00E+00 PU-244 3.83E+03 4.36E+03 1.01E+02 0.00E+00 3.72E+02 0.00E+00 2.76E+02 0.00E+00 AM-241 2.68E+04 2.30E+04 2.01E+03 0.00E+00 1.23E+04 0.00E+00 1.50E+03 0.00E+00 AM-242m 2.76E+04 2.21E+04 2.05E+03 0.00E+00 1.24E+04 0.00E+00 1.89E+03 0.00E+00 AM-243 2.64E+04 2.23E+04 1.94E+03 0.00E+00 1.19E+04 0.00E+00 1.76E+03 0.00E+00 CM-242 1.72E+03 1.37E+03 1.15E+02 0.00E+00 3.67E+02 0.00E+00 1.60E+03 0.00E+00 CM-243 2.52E+04 2.05E+04 1.62E+03 0.00E+00 6.06E+03 0.00E+00 1.58E+03 0.00E+00 CM-244 2.13E+04 1.72E+04 1.36E+03 0.00E+00 5.00E+03 0.00E+00 1.53E+03 0.00E+00 CM-245 3.29E+04 2.64E+04 2.07E+03 0.00E+00 8.09E+03 0.00E+00 1.43E+03 0.00E+00 CM-246 3.25E+04 2.64E+04 2.07E+03 0.00E+00 8.07E+03 0.00E+00 1.40E+03 0.00E+00 CM-247 3.17E+04 2.60E+04 2.03E+03 0.00E+00 7.96E+03 0.00E+00 1.84E+03 0.00E+00 CM-248 2.64E+05 2.15E+05 1.68E+04 0.00E+00 6.56E+04 0.00E+00 2.97E+04 0.00E+00 CF-252 2.07E+04 0.00E+00 5.00E+02 0.00E+00 0.00E+00 0.00E+00 5.82E+03 0.00E+00 II.4-90 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-22 (Page 1 of 4)
Teen Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 9.93E-02 9.93E-02 9.93E-02 9.93E-02 9.93E-02 9.93E-02 0.00E+00 C-14 3.41E+04 6.82E+03 6.82E+03 6.82E+03 6.82E+03 6.82E+03 6.82E+03 0.00E+00 NA-22 4.27E+03 4.27E+03 4.27E+03 4.27E+03 4.27E+03 4.27E+03 4.27E+03 0.00E+00 NA-24 1.39E+02 1.39E+02 1.39E+02 1.39E+02 1.39E+02 1.39E+02 1.39E+02 0.00E+00 P-32 1.44E+06 8.93E+04 5.59E+04 0.00E+00 0.00E+00 0.00E+00 1.21E+05 0.00E+00 CA-41 1.44E+04 0.00E+00 1.56E+03 0.00E+00 0.00E+00 0.00E+00 1.42E+01 0.00E+00 SC-46 2.62E-02 5.11E-02 1.51E-02 0.00E+00 4.89E-02 0.00E+00 1.74E+02 0.00E+00 CR-51 0.00E+00 0.00E+00 1.28E+00 7.13E-01 2.81E-01 1.83E+00 2.16E+02 0.00E+00 MN-54 0.00E+00 4.30E+03 8.53E+02 0.00E+00 1.28E+03 0.00E+00 8.82E+03 0.00E+00 FE-55 6.90E+02 4.89E+02 1.14E+02 0.00E+00 0.00E+00 3.10E+02 2.12E+02 0.00E+00 MN-56 0.00E+00 1.82E-01 3.24E-02 0.00E+00 2.31E-01 0.00E+00 1.20E+01 0.00E+00 CO-57 0.00E+00 2.17E+01 3.63E+01 0.00E+00 0.00E+00 0.00E+00 4.04E+02 0.00E+00 CO-58 0.00E+00 8.79E+01 2.03E+02 0.00E+00 0.00E+00 0.00E+00 1.21E+03 0.00E+00 FE-59 1.06E+03 2.46E+03 9.51E+02 0.00E+00 0.00E+00 7.77E+02 5.83E+03 0.00E+00 CO-60 0.00E+00 2.57E+02 5.78E+02 0.00E+00 0.00E+00 0.00E+00 3.34E+03 0.00E+00 NI-59 2.41E+03 8.51E+02 4.09E+02 0.00E+00 0.00E+00 0.00E+00 1.34E+02 0.00E+00 NI-63 3.23E+04 2.28E+03 1.10E+03 0.00E+00 0.00E+00 0.00E+00 3.63E+02 0.00E+00 CU-64 0.00E+00 2.83E+00 1.33E+00 0.00E+00 7.17E+00 0.00E+00 2.20E+02 0.00E+00 NI-65 1.86E-01 2.37E-02 1.08E-02 0.00E+00 0.00E+00 0.00E+00 1.29E+00 0.00E+00 ZN-65 2.10E+04 7.29E+04 3.40E+04 0.00E+00 4.66E+04 0.00E+00 3.09E+04 0.00E+00 ZN-69m 2.62E+02 6.17E+02 5.66E+01 0.00E+00 3.75E+02 0.00E+00 3.39E+04 0.00E+00 ZN-69 8.58E-07 1.63E-06 1.14E-07 0.00E+00 1.07E-06 0.00E+00 3.01E-06 0.00E+00 SE-79 0.00E+00 1.16E+03 1.95E+02 0.00E+00 2.02E+03 0.00E+00 1.77E+02 0.00E+00 BR-82 0.00E+00 0.00E+00 1.46E+03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 4.18E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 1.29E-12 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.43E-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.05E+05 4.93E+04 0.00E+00 0.00E+00 0.00E+00 1.55E+04 0.00E+00 RB-87 0.00E+00 6.39E+04 2.23E+04 0.00E+00 0.00E+00 0.00E+00 2.23E+03 0.00E+00 RB-88 0.00E+00 1.38E-22 7.36E-23 0.00E+00 0.00E+00 0.00E+00 1.18E-29 0.00E+00 RB-89 0.00E+00 1.69E-26 1.19E-26 0.00E+00 0.00E+00 0.00E+00 2.59E-35 0.00E+00 SR-89 2.38E+04 0.00E+00 6.81E+02 0.00E+00 0.00E+00 0.00E+00 2.83E+03 0.00E+00 SR-90 5.59E+05 0.00E+00 1.12E+04 0.00E+00 0.00E+00 0.00E+00 1.28E+04 0.00E+00 Y-90 4.83E-01 0.00E+00 1.30E-02 0.00E+00 0.00E+00 0.00E+00 3.98E+03 0.00E+00 SR-91 7.68E+01 0.00E+00 3.05E+00 0.00E+00 0.00E+00 0.00E+00 3.48E+02 0.00E+00 Y-91m 1.12E-11 0.00E+00 4.29E-13 0.00E+00 0.00E+00 0.00E+00 5.30E-10 0.00E+00 Y-91 9.07E+00 0.00E+00 2.43E-01 0.00E+00 0.00E+00 0.00E+00 3.72E+03 0.00E+00 II.4-91 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-22 (Page 2 of 4)
Teen Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 3.61E-01 0.00E+00 1.54E-02 0.00E+00 0.00E+00 0.00E+00 9.19E+00 0.00E+00 Y-92 5.03E-04 0.00E+00 1.45E-05 0.00E+00 0.00E+00 0.00E+00 1.38E+01 0.00E+00 Y-93 3.37E-02 0.00E+00 9.23E-04 0.00E+00 0.00E+00 0.00E+00 1.03E+03 0.00E+00 NB-93m 1.88E+03 6.19E+02 1.55E+02 0.00E+00 7.23E+02 0.00E+00 2.23E+05 0.00E+00 NB-95 4.42E+02 2.45E+02 1.35E+02 0.00E+00 2.37E+02 0.00E+00 1.05E+06 0.00E+00 NB-97 3.93E-06 9.75E-07 3.56E-07 0.00E+00 1.14E-06 0.00E+00 2.33E-02 0.00E+00 ZR-93 3.33E-01 1.65E-01 8.98E-02 0.00E+00 5.82E-01 0.00E+00 1.56E+02 0.00E+00 ZR-95 2.46E-01 7.75E-02 5.33E-02 0.00E+00 1.14E-01 0.00E+00 1.79E+02 0.00E+00 ZR-97 5.34E-03 1.06E-03 4.87E-04 0.00E+00 1.60E-03 0.00E+00 2.86E+02 0.00E+00 MO-93 0.00E+00 1.94E+02 5.30E+00 0.00E+00 5.55E+01 0.00E+00 2.36E+01 0.00E+00 MO-99 0.00E+00 8.56E+01 1.63E+01 0.00E+00 1.96E+02 0.00E+00 1.53E+02 0.00E+00 TC-99 4.90E+00 7.21E+00 1.96E+00 0.00E+00 9.15E+01 7.45E-01 1.76E+02 0.00E+00 TC-99m 5.74E-04 1.60E-03 2.07E-02 0.00E+00 2.38E-02 8.88E-04 1.05E+00 0.00E+00 TC-101 2.93E-33 4.17E-33 4.10E-32 0.00E+00 7.54E-32 2.54E-33 7.12E-40 0.00E+00 RU-103 4.58E+00 0.00E+00 1.96E+00 0.00E+00 1.61E+01 0.00E+00 3.82E+02 0.00E+00 RU-105 9.39E-03 0.00E+00 3.65E-03 0.00E+00 1.19E-01 0.00E+00 7.58E+00 0.00E+00 RU-106 7.15E+01 0.00E+00 9.01E+00 0.00E+00 1.38E+02 0.00E+00 3.43E+03 0.00E+00 RH-105 1.97E+00 1.43E+00 9.36E-01 0.00E+00 6.06E+00 0.00E+00 1.81E+02 0.00E+00 PD-107 0.00E+00 3.80E+00 2.45E-01 0.00E+00 3.43E+01 0.00E+00 1.76E+01 0.00E+00 PD-109 0.00E+00 1.33E+00 3.02E-01 0.00E+00 7.69E+00 0.00E+00 1.34E+02 0.00E+00 AG-110m 8.59E-01 8.13E-01 4.94E-01 0.00E+00 1.55E+00 0.00E+00 2.28E+02 0.00E+00 AG-111 3.17E-01 1.32E-01 6.62E-02 0.00E+00 4.29E-01 0.00E+00 1.84E+02 0.00E+00 CD-113m 0.00E+00 1.65E+03 5.30E+01 0.00E+00 1.82E+03 0.00E+00 9.90E+03 0.00E+00 CD-115m 0.00E+00 9.35E+02 3.02E+01 0.00E+00 7.48E+02 0.00E+00 2.96E+04 0.00E+00 SN-123 2.42E+05 3.97E+03 5.89E+03 3.18E+03 0.00E+00 0.00E+00 3.66E+05 0.00E+00 SN-125 6.07E+04 1.21E+03 2.74E+03 9.48E+02 0.00E+00 0.00E+00 5.71E+05 0.00E+00 SN-126 6.36E+05 1.18E+04 1.81E+04 3.12E+03 0.00E+00 0.00E+00 1.41E+05 0.00E+00 SB-124 6.99E+00 1.29E-01 2.73E+00 1.59E-02 0.00E+00 6.10E+00 1.41E+02 0.00E+00 SB-125 4.53E+00 4.95E-02 1.06E+00 4.33E-03 0.00E+00 3.98E+00 3.52E+01 0.00E+00 SB-126 2.75E+00 5.61E-02 9.86E-01 1.55E-02 0.00E+00 1.97E+00 1.63E+02 0.00E+00 SB-127 5.54E-01 1.18E-02 2.09E-01 6.22E-03 0.00E+00 3.77E-01 9.40E+01 0.00E+00 TE-125m 2.76E+03 9.96E+02 3.70E+02 7.72E+02 0.00E+00 0.00E+00 8.16E+03 0.00E+00 TE-127m 7.02E+03 2.49E+03 8.35E+02 1.67E+03 2.85E+04 0.00E+00 1.75E+04 0.00E+00 TE-127 1.95E+01 6.91E+00 4.19E+00 1.34E+01 7.89E+01 0.00E+00 1.50E+03 0.00E+00 TE-129m 1.17E+04 4.33E+03 1.85E+03 3.76E+03 4.88E+04 0.00E+00 4.38E+04 0.00E+00 TE-129 1.94E-05 7.21E-06 4.71E-06 1.38E-05 8.12E-05 0.00E+00 1.06E-04 0.00E+00 TE-133m 7.05E-07 4.00E-07 3.90E-07 5.59E-07 3.96E-06 0.00E+00 1.62E-06 0.00E+00 II.4-92 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-22 (Page 3 of 4)
Teen Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 1.39E-09 8.94E-10 9.34E-10 1.14E-09 8.53E-09 0.00E+00 5.17E-11 0.00E+00 I-129 1.28E+02 1.07E+02 1.79E+02 1.31E+05 1.92E+02 0.00E+00 1.25E+01 0.00E+00 I-130 7.35E+00 2.13E+01 8.49E+00 1.73E+03 3.27E+01 0.00E+00 1.63E+01 0.00E+00 I-131 1.47E+02 2.06E+02 1.11E+02 6.01E+04 3.54E+02 0.00E+00 4.07E+01 0.00E+00 TE-131m 1.02E+03 4.91E+02 4.10E+02 7.39E+02 5.12E+03 0.00E+00 3.94E+04 0.00E+00 TE-131 9.33E-17 3.85E-17 2.92E-17 7.19E-17 4.08E-16 0.00E+00 7.66E-18 0.00E+00 I-132 5.52E-03 1.44E-02 5.19E-03 4.87E-01 2.28E-02 0.00E+00 6.29E-03 0.00E+00 TE-132 2.06E+03 1.31E+03 1.23E+03 1.38E+03 1.25E+04 0.00E+00 4.13E+04 0.00E+00 I-133 2.47E+01 4.20E+01 1.28E+01 5.86E+03 7.36E+01 0.00E+00 3.18E+01 0.00E+00 CS-134m 3.47E-01 7.18E-01 3.69E-01 0.00E+00 4.00E-01 7.01E-02 4.77E-01 0.00E+00 CS-134 3.05E+05 7.19E+05 3.34E+05 0.00E+00 2.28E+05 8.72E+04 8.94E+03 0.00E+00 I-134 2.30E-08 6.09E-08 2.19E-08 1.01E-06 9.59E-08 0.00E+00 8.02E-10 0.00E+00 I-135 1.35E+00 3.47E+00 1.29E+00 2.23E+02 5.48E+00 0.00E+00 3.85E+00 0.00E+00 CS-135 1.02E+05 9.32E+04 2.18E+04 0.00E+00 3.55E+04 1.29E+04 1.63E+03 0.00E+00 CS-136 2.98E+04 1.17E+05 7.87E+04 0.00E+00 6.38E+04 1.01E+04 9.43E+03 0.00E+00 CS-137 4.09E+05 5.44E+05 1.90E+05 0.00E+00 1.85E+05 7.20E+04 7.74E+03 0.00E+00 CS-138 9.78E-12 1.88E-11 9.39E-12 0.00E+00 1.39E-11 1.61E-12 8.52E-15 0.00E+00 CS-139 1.36E-44 2.01E-44 7.37E-45 0.00E+00 1.62E-44 1.78E-45 9.33E-60 0.00E+00 BA-139 6.17E-06 4.34E-09 1.80E-07 0.00E+00 4.09E-09 2.99E-09 5.50E-05 0.00E+00 BA-140 1.97E+02 2.41E-01 1.27E+01 0.00E+00 8.17E-02 1.62E-01 3.03E+02 0.00E+00 LA-140 1.05E-01 5.16E-02 1.37E-02 0.00E+00 0.00E+00 0.00E+00 2.97E+03 0.00E+00 BA-141 9.20E-25 6.87E-28 3.07E-26 0.00E+00 6.38E-28 4.70E-28 1.96E-30 0.00E+00 LA-141 3.05E-04 9.38E-05 1.55E-05 0.00E+00 0.00E+00 0.00E+00 1.66E+01 0.00E+00 CE-141 2.38E-02 1.59E-02 1.82E-03 0.00E+00 7.47E-03 0.00E+00 4.54E+01 0.00E+00 BA-142 6.71E-42 6.71E-45 4.13E-43 0.00E+00 5.68E-45 4.47E-45 2.06E-53 0.00E+00 LA-142 2.34E-07 1.04E-07 2.58E-08 0.00E+00 0.00E+00 0.00E+00 3.16E-03 0.00E+00 CE-143 2.59E-03 1.89E+00 2.11E-04 0.00E+00 8.46E-04 0.00E+00 5.67E+01 0.00E+00 PR-143 5.68E-01 2.27E-01 2.83E-02 0.00E+00 1.32E-01 0.00E+00 1.87E+03 0.00E+00 CE-144 1.27E+00 5.25E-01 6.81E-02 0.00E+00 3.13E-01 0.00E+00 3.19E+02 0.00E+00 PR-144 1.61E-28 6.60E-29 8.17E-30 0.00E+00 3.78E-29 0.00E+00 1.78E-31 0.00E+00 ND-147 4.02E-01 4.37E-01 2.62E-02 0.00E+00 2.57E-01 0.00E+00 1.58E+03 0.00E+00 PM-147 4.79E+00 4.54E-01 1.85E-01 0.00E+00 8.67E-01 0.00E+00 4.32E+02 0.00E+00 PM-148m 1.86E+00 4.71E-01 3.69E-01 0.00E+00 7.14E-01 0.00E+00 2.97E+03 0.00E+00 PM-148 4.09E-01 6.66E-02 3.36E-02 0.00E+00 1.20E-01 0.00E+00 3.97E+03 0.00E+00 PM-149 7.24E-02 1.02E-02 4.17E-03 0.00E+00 1.94E-02 0.00E+00 1.50E+03 0.00E+00 PM-151 2.51E-02 4.14E-03 2.10E-03 0.00E+00 7.45E-03 0.00E+00 9.30E+02 0.00E+00 SM-151 3.99E+00 7.67E-01 1.80E-01 0.00E+00 8.40E-01 0.00E+00 2.60E+02 0.00E+00 II.4-93 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-22 (Page 4 of 4)
Teen Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 3.90E-02 3.23E-02 2.38E-03 0.00E+00 1.06E-02 0.00E+00 9.11E+02 0.00E+00 EU-152 1.12E+01 2.69E+00 2.37E+00 0.00E+00 1.25E+01 0.00E+00 9.91E+02 0.00E+00 EU-154 3.61E+01 4.66E+00 3.28E+00 0.00E+00 2.08E+01 0.00E+00 2.46E+03 0.00E+00 EU-155 7.94E+00 7.67E-01 4.75E-01 0.00E+00 3.00E+00 0.00E+00 4.40E+03 0.00E+00 EU-156 8.38E-01 6.28E-01 1.03E-01 0.00E+00 4.23E-01 0.00E+00 3.21E+03 0.00E+00 TB-160 2.93E+00 0.00E+00 3.65E-01 0.00E+00 1.16E+00 0.00E+00 1.89E+03 0.00E+00 HO-166m 1.63E+01 5.02E+00 3.63E+00 0.00E+00 7.35E+00 0.00E+00 4.57E-17 0.00E+00 W-181 3.09E+01 9.98E+00 1.04E+00 0.00E+00 0.00E+00 0.00E+00 8.50E+02 0.00E+00 W-185 1.26E+03 4.15E+02 4.39E+01 0.00E+00 0.00E+00 0.00E+00 3.58E+04 0.00E+00 W-187 1.59E+02 1.30E+02 4.55E+01 0.00E+00 0.00E+00 0.00E+00 3.51E+04 0.00E+00 NP-239 2.39E-02 2.26E-03 1.25E-03 0.00E+00 7.09E-03 0.00E+00 3.63E+02 0.00E+00 U-232 2.15E+04 0.00E+00 1.54E+03 0.00E+00 2.33E+03 0.00E+00 2.63E+02 0.00E+00 U-233 4.53E+03 0.00E+00 2.75E+02 0.00E+00 1.06E+03 0.00E+00 2.43E+02 0.00E+00 U-234 4.35E+03 0.00E+00 2.70E+02 0.00E+00 1.04E+03 0.00E+00 2.38E+02 0.00E+00 U-235 4.16E+03 0.00E+00 2.54E+02 0.00E+00 9.75E+02 0.00E+00 3.02E+02 0.00E+00 U-236 4.16E+03 0.00E+00 2.59E+02 0.00E+00 9.97E+02 0.00E+00 2.23E+02 0.00E+00 U-237 2.60E-01 0.00E+00 6.92E-02 0.00E+00 1.07E+00 0.00E+00 6.89E+01 0.00E+00 U-238 3.98E+03 0.00E+00 2.37E+02 0.00E+00 9.13E+02 0.00E+00 2.13E+02 0.00E+00 NP-237 2.43E+04 1.74E+03 1.07E+03 0.00E+00 7.91E+03 0.00E+00 1.54E+03 0.00E+00 NP-238 2.57E-01 6.87E-03 4.00E-03 0.00E+00 2.36E-02 0.00E+00 5.04E+02 0.00E+00 PU-238 4.28E+03 5.48E+02 1.16E+02 0.00E+00 4.99E+02 0.00E+00 4.94E+02 0.00E+00 PU-239 4.89E+03 5.94E+02 1.28E+02 0.00E+00 5.48E+02 0.00E+00 4.51E+02 0.00E+00 PU-240 4.88E+03 5.93E+02 1.28E+02 0.00E+00 5.47E+02 0.00E+00 4.60E+02 0.00E+00 PU-241 1.12E+02 5.37E+00 2.36E+00 0.00E+00 1.09E+01 0.00E+00 9.46E+00 0.00E+00 PU-242 4.53E+03 5.72E+02 1.24E+02 0.00E+00 5.27E+02 0.00E+00 4.42E+02 0.00E+00 PU-244 5.29E+03 6.52E+02 1.42E+02 0.00E+00 6.04E+02 0.00E+00 6.58E+02 0.00E+00 AM-241 3.64E+04 3.44E+04 2.63E+03 0.00E+00 1.97E+04 0.00E+00 3.59E+03 0.00E+00 AM-242m 3.68E+04 3.25E+04 2.65E+03 0.00E+00 1.96E+04 0.00E+00 4.52E+03 0.00E+00 AM-243 3.63E+04 3.36E+04 2.57E+03 0.00E+00 1.93E+04 0.00E+00 4.21E+03 0.00E+00 CM-242 1.34E+03 1.41E+03 8.87E+01 0.00E+00 4.04E+02 0.00E+00 3.82E+03 0.00E+00 CM-243 2.97E+04 2.75E+04 1.87E+03 0.00E+00 8.72E+03 0.00E+00 3.78E+03 0.00E+00 CM-244 2.30E+04 2.18E+04 1.46E+03 0.00E+00 6.80E+03 0.00E+00 3.65E+03 0.00E+00 CM-245 4.52E+04 3.98E+04 2.79E+03 0.00E+00 1.30E+04 0.00E+00 3.41E+03 0.00E+00 CM-246 4.48E+04 3.97E+04 2.78E+03 0.00E+00 1.30E+04 0.00E+00 3.35E+03 0.00E+00 CM-247 4.37E+04 3.91E+04 2.74E+03 0.00E+00 1.28E+04 0.00E+00 4.40E+03 0.00E+00 CM-248 3.63E+05 3.22E+05 2.26E+04 0.00E+00 1.05E+05 0.00E+00 7.08E+04 0.00E+00 CF-252 1.58E+04 0.00E+00 3.82E+02 0.00E+00 0.00E+00 0.00E+00 1.39E+04 0.00E+00 II.4-94 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-23 (Page 1 of 4)
Adult Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 0.00E+00 C-14 3.13E+04 6.26E+03 6.26E+03 6.26E+03 6.26E+03 6.26E+03 6.26E+03 0.00E+00 NA-22 4.17E+03 4.17E+03 4.17E+03 4.17E+03 4.17E+03 4.17E+03 4.17E+03 0.00E+00 NA-24 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.34E+02 0.00E+00 P-32 1.32E+06 8.22E+04 5.11E+04 0.00E+00 0.00E+00 0.00E+00 1.49E+05 0.00E+00 CA-41 1.77E+04 0.00E+00 1.92E+03 0.00E+00 0.00E+00 0.00E+00 1.76E+01 0.00E+00 SC-46 2.62E-02 5.09E-02 1.48E-02 0.00E+00 4.75E-02 0.00E+00 2.48E+02 0.00E+00 CR-51 0.00E+00 0.00E+00 1.24E+00 7.43E-01 2.74E-01 1.65E+00 3.13E+02 0.00E+00 MN-54 0.00E+00 4.37E+03 8.34E+02 0.00E+00 1.30E+03 0.00E+00 1.34E+04 0.00E+00 FE-55 6.59E+02 4.55E+02 1.06E+02 0.00E+00 0.00E+00 2.54E+02 2.61E+02 0.00E+00 MN-56 0.00E+00 1.74E-01 3.09E-02 0.00E+00 2.21E-01 0.00E+00 5.55E+00 0.00E+00 CO-57 0.00E+00 2.09E+01 3.48E+01 0.00E+00 0.00E+00 0.00E+00 5.31E+02 0.00E+00 CO-58 0.00E+00 8.84E+01 1.98E+02 0.00E+00 0.00E+00 0.00E+00 1.79E+03 0.00E+00 FE-59 1.02E+03 2.41E+03 9.23E+02 0.00E+00 0.00E+00 6.73E+02 8.03E+03 0.00E+00 CO-60 0.00E+00 2.56E+02 5.66E+02 0.00E+00 0.00E+00 0.00E+00 4.82E+03 0.00E+00 NI-59 2.34E+03 8.03E+02 3.91E+02 0.00E+00 0.00E+00 0.00E+00 1.65E+02 0.00E+00 NI-63 3.12E+04 2.16E+03 1.05E+03 0.00E+00 0.00E+00 0.00E+00 4.51E+02 0.00E+00 CU-64 0.00E+00 2.69E+00 1.26E+00 0.00E+00 6.79E+00 0.00E+00 2.30E+02 0.00E+00 NI-65 1.72E-01 2.23E-02 1.02E-02 0.00E+00 0.00E+00 0.00E+00 5.67E-01 0.00E+00 ZN-65 2.31E+04 7.36E+04 3.33E+04 0.00E+00 4.92E+04 0.00E+00 4.64E+04 0.00E+00 ZN-69m 2.43E+02 5.84E+02 5.34E+01 0.00E+00 3.53E+02 0.00E+00 3.56E+04 0.00E+00 ZN-69 7.89E-07 1.51E-06 1.05E-07 0.00E+00 9.81E-07 0.00E+00 2.27E-07 0.00E+00 SE-79 0.00E+00 1.07E+03 1.79E+02 0.00E+00 1.85E+03 0.00E+00 2.19E+02 0.00E+00 BR-82 0.00E+00 0.00E+00 1.42E+03 0.00E+00 0.00E+00 0.00E+00 1.63E+03 0.00E+00 BR-83 0.00E+00 0.00E+00 3.84E-02 0.00E+00 0.00E+00 0.00E+00 5.53E-02 0.00E+00 BR-84 0.00E+00 0.00E+00 1.23E-12 0.00E+00 0.00E+00 0.00E+00 9.62E-18 0.00E+00 BR-85 0.00E+00 0.00E+00 1.31E-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 9.75E+04 4.54E+04 0.00E+00 0.00E+00 0.00E+00 1.92E+04 0.00E+00 RB-87 0.00E+00 5.90E+04 2.05E+04 0.00E+00 0.00E+00 0.00E+00 2.76E+03 0.00E+00 RB-88 0.00E+00 1.29E-22 6.83E-23 0.00E+00 0.00E+00 0.00E+00 1.78E-33 0.00E+00 RB-89 0.00E+00 1.62E-26 1.14E-26 0.00E+00 0.00E+00 0.00E+00 9.39E-40 0.00E+00 SR-89 2.18E+04 0.00E+00 6.27E+02 0.00E+00 0.00E+00 0.00E+00 3.50E+03 0.00E+00 SR-90 6.26E+05 0.00E+00 1.26E+04 0.00E+00 0.00E+00 0.00E+00 1.57E+04 0.00E+00 Y-90 4.45E-01 0.00E+00 1.19E-02 0.00E+00 0.00E+00 0.00E+00 4.72E+03 0.00E+00 SR-91 7.08E+01 0.00E+00 2.86E+00 0.00E+00 0.00E+00 0.00E+00 3.37E+02 0.00E+00 Y-91m 1.04E-11 0.00E+00 4.02E-13 0.00E+00 0.00E+00 0.00E+00 3.05E-11 0.00E+00 Y-91 8.35E+00 0.00E+00 2.23E-01 0.00E+00 0.00E+00 0.00E+00 4.60E+03 0.00E+00 II.4-95 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-23 (Page 2 of 4)
Adult Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 3.34E-01 0.00E+00 1.44E-02 0.00E+00 0.00E+00 0.00E+00 6.61E+00 0.00E+00 Y-92 4.61E-04 0.00E+00 1.35E-05 0.00E+00 0.00E+00 0.00E+00 8.07E+00 0.00E+00 Y-93 3.09E-02 0.00E+00 8.54E-04 0.00E+00 0.00E+00 0.00E+00 9.81E+02 0.00E+00 NB-93m 1.83E+03 5.98E+02 1.47E+02 0.00E+00 6.88E+02 0.00E+00 2.76E+05 0.00E+00 NB-95 4.39E+02 2.44E+02 1.31E+02 0.00E+00 2.41E+02 0.00E+00 1.48E+06 0.00E+00 NB-97 3.65E-06 9.23E-07 3.37E-07 0.00E+00 1.08E-06 0.00E+00 3.40E-03 0.00E+00 ZR-93 3.31E-01 1.85E-02 8.62E-03 0.00E+00 7.02E-02 0.00E+00 1.92E+01 0.00E+00 ZR-95 2.38E-01 7.63E-02 5.17E-02 0.00E+00 1.20E-01 0.00E+00 2.42E+02 0.00E+00 ZR-97 4.97E-03 1.00E-03 4.58E-04 0.00E+00 1.51E-03 0.00E+00 3.10E+02 0.00E+00 MO-93 0.00E+00 1.80E+02 4.87E+00 0.00E+00 5.11E+01 0.00E+00 2.92E+01 0.00E+00 MO-99 0.00E+00 8.03E+01 1.53E+01 0.00E+00 1.82E+02 0.00E+00 1.86E+02 0.00E+00 TC-99 4.49E+00 6.69E+00 1.81E+00 0.00E+00 8.41E+01 5.68E-01 2.19E+02 0.00E+00 TC-99m 5.60E-04 1.58E-03 2.02E-02 0.00E+00 2.40E-02 7.76E-04 9.37E-01 0.00E+00 TC-101 2.71E-33 3.91E-33 3.84E-32 0.00E+00 7.04E-32 2.00E-33 1.18E-44 0.00E+00 RU-103 4.36E+00 0.00E+00 1.88E+00 0.00E+00 1.66E+01 0.00E+00 5.09E+02 0.00E+00 RU-105 8.71E-03 0.00E+00 3.44E-03 0.00E+00 1.13E-01 0.00E+00 5.33E+00 0.00E+00 RU-106 6.58E+01 0.00E+00 8.33E+00 0.00E+00 1.27E+02 0.00E+00 4.26E+03 0.00E+00 RH-105 1.81E+00 1.33E+00 8.73E-01 0.00E+00 5.63E+00 0.00E+00 2.11E+02 0.00E+00 PD-107 0.00E+00 3.52E+00 2.25E-01 0.00E+00 3.16E+01 0.00E+00 2.18E+01 0.00E+00 PD-109 0.00E+00 1.23E+00 2.78E-01 0.00E+00 7.03E+00 0.00E+00 1.36E+02 0.00E+00 AG-110m 8.80E-01 8.14E-01 4.83E-01 0.00E+00 1.60E+00 0.00E+00 3.32E+02 0.00E+00 AG-111 2.92E-01 1.22E-01 6.08E-02 0.00E+00 3.94E-01 0.00E+00 2.24E+02 0.00E+00 CD-113m 0.00E+00 1.52E+03 4.89E+01 0.00E+00 1.68E+03 0.00E+00 1.23E+04 0.00E+00 CD-115m 0.00E+00 8.69E+02 2.77E+01 0.00E+00 6.89E+02 0.00E+00 3.65E+04 0.00E+00 SN-123 2.22E+05 3.68E+03 5.43E+03 3.13E+03 0.00E+00 0.00E+00 4.53E+05 0.00E+00 SN-125 5.58E+04 1.12E+03 2.53E+03 9.30E+02 0.00E+00 0.00E+00 6.96E+05 0.00E+00 SN-126 6.08E+05 1.20E+04 1.73E+04 3.54E+03 0.00E+00 0.00E+00 1.75E+05 0.00E+00 SB-124 6.64E+00 1.25E-01 2.63E+00 1.61E-02 0.00E+00 5.17E+00 1.88E+02 0.00E+00 SB-125 4.29E+00 4.79E-02 1.02E+00 4.36E-03 0.00E+00 3.31E+00 4.72E+01 0.00E+00 SB-126 2.61E+00 5.30E-02 9.41E-01 1.60E-02 0.00E+00 1.60E+00 2.13E+02 0.00E+00 SB-127 5.17E-01 1.13E-02 1.98E-01 6.21E-03 0.00E+00 3.06E-01 1.18E+02 0.00E+00 TE-125m 2.54E+03 9.20E+02 3.40E+02 7.64E+02 1.03E+04 0.00E+00 1.01E+04 0.00E+00 TE-127m 6.45E+03 2.31E+03 7.86E+02 1.65E+03 2.62E+04 0.00E+00 2.16E+04 0.00E+00 TE-127 1.78E+01 6.39E+00 3.85E+00 1.32E+01 7.25E+01 0.00E+00 1.40E+03 0.00E+00 TE-129m 1.08E+04 4.03E+03 1.71E+03 3.71E+03 4.51E+04 0.00E+00 5.44E+04 0.00E+00 TE-129 1.78E-05 6.69E-06 4.34E-06 1.37E-05 7.48E-05 0.00E+00 1.34E-05 0.00E+00 TE-133m 6.63E-07 3.88E-07 3.73E-07 5.61E-07 3.83E-06 0.00E+00 1.33E-07 0.00E+00 II.4-96 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-23 (Page 3 of 4)
Adult Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 1.32E-09 8.66E-10 5.31E-10 1.16E-09 8.38E-09 0.00E+00 1.47E-12 0.00E+00 I-129 1.18E+02 1.01E+02 3.31E+02 2.60E+05 2.17E+02 0.00E+00 1.60E+01 0.00E+00 I-130 7.08E+00 2.09E+01 8.24E+00 1.77E+03 3.26E+01 0.00E+00 1.80E+01 0.00E+00 I-131 1.37E+02 1.96E+02 1.12E+02 6.43E+04 3.36E+02 0.00E+00 5.18E+01 0.00E+00 TE-131m 9.53E+02 4.66E+02 3.88E+02 7.38E+02 4.72E+03 0.00E+00 4.63E+04 0.00E+00 TE-131 8.65E-17 3.61E-17 2.73E-17 7.11E-17 3.79E-16 0.00E+00 1.22E-17 0.00E+00 I-132 5.27E-03 1.41E-02 4.94E-03 4.94E-01 2.25E-02 0.00E+00 2.65E-03 0.00E+00 TE-132 1.95E+03 1.26E+03 1.19E+03 1.40E+03 1.22E+04 0.00E+00 5.98E+04 0.00E+00 I-133 2.29E+01 3.99E+01 1.22E+01 5.87E+03 6.97E+01 0.00E+00 3.59E+01 0.00E+00 CS-134m 3.29E-01 6.93E-01 3.54E-01 0.00E+00 3.76E-01 5.92E-02 2.44E-01 0.00E+00 CS-134 2.98E+05 7.09E+05 5.80E+05 0.00E+00 2.29E+05 7.62E+04 1.24E+04 0.00E+00 I-134 2.19E-08 5.94E-08 2.13E-08 1.03E-06 9.45E-08 0.00E+00 5.18E-11 0.00E+00 I-135 1.29E+00 3.37E+00 1.24E+00 2.22E+02 5.40E+00 0.00E+00 3.80E+00 0.00E+00 CS-135 9.35E+04 8.63E+04 3.83E+04 0.00E+00 3.27E+04 9.78E+03 2.02E+03 0.00E+00 CS-136 2.96E+04 1.17E+05 8.41E+04 0.00E+00 6.50E+04 8.92E+03 1.33E+04 0.00E+00 CS-137 3.82E+05 5.23E+05 3.42E+05 0.00E+00 1.77E+05 5.90E+04 1.01E+04 0.00E+00 CS-138 9.13E-12 1.80E-11 8.93E-12 0.00E+00 1.32E-11 1.31E-12 7.69E-17 0.00E+00 CS-139 1.25E-44 1.87E-44 6.80E-45 0.00E+00 1.50E-44 1.36E-45 4.04E-67 0.00E+00 BA-139 5.65E-06 4.03E-09 1.65E-07 0.00E+00 3.76E-09 2.28E-09 1.00E-05 0.00E+00 BA-140 1.84E+02 2.32E-01 1.21E+01 0.00E+00 7.88E-02 1.33E-01 3.80E+02 0.00E+00 LA-140 9.91E-02 4.99E-02 1.32E-02 0.00E+00 0.00E+00 0.00E+00 3.67E+03 0.00E+00 BA-141 8.48E-25 6.41E-28 2.86E-26 0.00E+00 5.96E-28 3.64E-28 4.00E-34 0.00E+00 LA-141 2.80E-04 8.70E-05 1.42E-05 0.00E+00 0.00E+00 0.00E+00 1.04E+01 0.00E+00 CE-141 2.20E-02 1.49E-02 1.68E-03 0.00E+00 6.90E-03 0.00E+00 5.68E+01 0.00E+00 BA-142 6.28E-42 6.45E-45 3.95E-43 0.00E+00 5.45E-45 3.65E-45 8.84E-60 0.00E+00 LA-142 2.19E-07 9.97E-08 2.48E-08 0.00E+00 0.00E+00 0.00E+00 7.28E-04 0.00E+00 CE-143 2.39E-03 1.77E+00 1.95E-04 0.00E+00 7.78E-04 0.00E+00 6.60E+01 0.00E+00 PR-143 5.24E-01 2.10E-01 2.60E-02 0.00E+00 1.21E-01 0.00E+00 2.29E+03 0.00E+00 CE-144 1.17E+00 4.88E-01 6.27E-02 0.00E+00 2.89E-01 0.00E+00 3.95E+02 0.00E+00 PR-144 1.48E-28 6.15E-29 7.53E-30 0.00E+00 3.47E-29 0.00E+00 2.13E-35 0.00E+00 ND-147 3.54E-01 4.09E-01 2.45E-02 0.00E+00 2.39E-01 0.00E+00 1.96E+03 0.00E+00 PM-147 4.52E+00 4.25E-01 1.72E-01 0.00E+00 8.03E-01 0.00E+00 5.35E+02 0.00E+00 PM-148m 1.81E+00 4.69E-01 3.58E-01 0.00E+00 7.07E-01 0.00E+00 3.97E+03 0.00E+00 PM-148 3.78E-01 6.27E-02 3.16E-02 0.00E+00 1.19E-01 0.00E+00 4.93E+03 0.00E+00 PM-149 6.66E-02 9.42E-03 3.85E-03 0.00E+00 1.78E-02 0.00E+00 1.77E+03 0.00E+00 PM-151 2.33E-02 3.90E-03 1.97E-03 0.00E+00 6.97E-03 0.00E+00 1.07E+03 0.00E+00 SM-151 4.14E+00 7.13E-01 1.71E-01 0.00E+00 7.97E-01 0.00E+00 3.15E+02 0.00E+00 II.4-97 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-23 (Page 4 of 4)
Adult Fish Ait mrem*mL/hr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 3.60E-02 3.00E-02 2.19E-03 0.00E+00 9.70E-03 0.00E+00 1.07E+03 0.00E+00 EU-152 1.17E+01 2.66E+00 2.34E+00 0.00E+00 1.65E+01 0.00E+00 1.53E+03 0.00E+00 EU-154 3.68E+01 4.53E+00 3.22E+00 0.00E+00 2.17E+01 0.00E+00 3.28E+03 0.00E+00 EU-155 5.15E+00 7.31E-01 4.71E-01 0.00E+00 3.37E+00 0.00E+00 5.75E+02 0.00E+00 EU-156 7.84E-01 6.07E-01 9.79E-02 0.00E+00 4.05E-01 0.00E+00 4.16E+03 0.00E+00 TB-160 2.79E+00 0.00E+00 3.48E-01 0.00E+00 1.15E+00 0.00E+00 1.52E+03 0.00E+00 HO-166m 1.62E+01 5.05E+00 3.84E+00 0.00E+00 7.55E+00 0.00E+00 5.99E-17 0.00E+00 W-181 2.83E+01 9.24E+00 9.90E-01 0.00E+00 0.00E+00 0.00E+00 1.05E+03 0.00E+00 W-185 1.15E+03 3.85E+02 4.05E+01 0.00E+00 0.00E+00 0.00E+00 4.45E+04 0.00E+00 W-187 1.47E+02 1.23E+02 4.31E+01 0.00E+00 0.00E+00 0.00E+00 4.04E+04 0.00E+00 NP-239 2.13E-02 2.09E-03 1.15E-03 0.00E+00 6.52E-03 0.00E+00 4.29E+02 0.00E+00 U-232 1.98E+04 0.00E+00 1.41E+03 0.00E+00 2.14E+03 0.00E+00 3.25E+02 0.00E+00 U-233 4.18E+03 0.00E+00 2.53E+02 0.00E+00 9.73E+02 0.00E+00 3.01E+02 0.00E+00 U-234 4.01E+03 0.00E+00 2.48E+02 0.00E+00 9.54E+02 0.00E+00 2.94E+02 0.00E+00 U-235 3.84E+03 0.00E+00 2.33E+02 0.00E+00 8.97E+02 0.00E+00 3.74E+02 0.00E+00 U-236 3.84E+03 0.00E+00 2.38E+02 0.00E+00 9.16E+02 0.00E+00 2.76E+02 0.00E+00 U-237 2.39E-01 0.00E+00 6.36E-02 0.00E+00 9.82E-01 0.00E+00 8.39E+01 0.00E+00 U-238 3.68E+03 0.00E+00 2.18E+02 0.00E+00 8.39E+02 0.00E+00 2.64E+02 0.00E+00 NP-237 3.02E+04 2.15E+03 1.33E+03 0.00E+00 9.88E+03 0.00E+00 1.90E+03 0.00E+00 NP-238 2.37E-01 6.38E-03 3.68E-03 0.00E+00 2.16E-02 0.00E+00 5.93E+02 0.00E+00 PU-238 5.29E+03 6.70E+02 1.43E+02 0.00E+00 6.14E+02 0.00E+00 6.12E+02 0.00E+00 PU-239 6.08E+03 7.31E+02 1.60E+02 0.00E+00 6.80E+02 0.00E+00 5.59E+02 0.00E+00 PU-240 6.07E+03 7.30E+02 1.60E+02 0.00E+00 6.80E+02 0.00E+00 5.69E+02 0.00E+00 PU-241 1.32E+02 6.25E+00 2.79E+00 0.00E+00 1.28E+01 0.00E+00 1.17E+01 0.00E+00 PU-242 5.64E+03 7.04E+02 1.54E+02 0.00E+00 6.55E+02 0.00E+00 5.48E+02 0.00E+00 PU-244 6.58E+03 8.06E+02 1.77E+02 0.00E+00 7.51E+02 0.00E+00 8.16E+02 0.00E+00 AM-241 4.52E+04 4.23E+04 3.24E+03 0.00E+00 2.44E+04 0.00E+00 4.45E+03 0.00E+00 AM-242m 4.56E+04 3.97E+04 3.25E+03 0.00E+00 2.43E+04 0.00E+00 5.60E+03 0.00E+00 AM-243 4.52E+04 4.14E+04 3.18E+03 0.00E+00 2.39E+04 0.00E+00 5.21E+03 0.00E+00 CM-242 1.23E+03 1.31E+03 8.18E+01 0.00E+00 3.71E+02 0.00E+00 4.73E+03 0.00E+00 CM-243 3.59E+04 3.29E+04 2.25E+03 0.00E+00 1.05E+04 0.00E+00 4.68E+03 0.00E+00 CM-244 2.73E+04 2.56E+04 1.72E+03 0.00E+00 8.03E+03 0.00E+00 4.52E+03 0.00E+00 CM-245 5.62E+04 4.90E+04 3.45E+03 0.00E+00 1.61E+04 0.00E+00 4.22E+03 0.00E+00 CM-246 5.57E+04 4.89E+04 3.45E+03 0.00E+00 1.61E+04 0.00E+00 4.14E+03 0.00E+00 CM-247 5.44E+04 4.82E+04 3.40E+03 0.00E+00 1.58E+04 0.00E+00 5.45E+03 0.00E+00 CM-248 4.52E+05 3.97E+05 2.80E+04 0.00E+00 1.31E+05 0.00E+00 8.81E+04 0.00E+00 CF-252 1.56E+04 0.00E+00 3.77E+02 0.00E+00 0.00E+00 0.00E+00 1.72E+04 0.00E+00 II.4-98 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-24 (Page 1 of 4)
Infant Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 0.00E+00 C-14 2.65E+04 5.31E+03 5.31E+03 5.31E+03 5.31E+03 5.31E+03 5.31E+03 0.00E+00 NA-22 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 0.00E+00 NA-24 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 0.00E+00 P-32 2.03E+06 1.12E+05 7.74E+04 0.00E+00 0.00E+00 0.00E+00 1.61E+04 0.00E+00 CA-41 1.05E+05 0.00E+00 1.14E+04 0.00E+00 0.00E+00 9.72E+07 4.14E+02 0.00E+00 SC-46 5.25E+05 7.57E+05 2.37E+05 0.00E+00 4.98E+05 0.00E+00 3.07E+04 0.00E+00 CR-51 0.00E+00 0.00E+00 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 0.00E+00 MN-54 0.00E+00 2.53E+04 4.98E+03 0.00E+00 4.98E+03 1.00E+06 7.06E+03 0.00E+00 FE-55 1.97E+04 1.18E+04 3.33E+03 0.00E+00 0.00E+00 8.69E+04 1.10E+03 0.00E+00 MN-56 0.00E+00 1.54E+00 2.21E-01 0.00E+00 1.10E+00 1.25E+04 7.17E+04 0.00E+00 CO-57 0.00E+00 6.51E+02 6.41E+02 0.00E+00 0.00E+00 3.79E+05 4.86E+03 0.00E+00 CO-58 0.00E+00 1.22E+03 1.82E+03 0.00E+00 0.00E+00 7.77E+05 1.11E+04 0.00E+00 FE-59 1.36E+04 2.35E+04 9.48E+03 0.00E+00 0.00E+00 1.02E+06 2.48E+04 0.00E+00 CO-60 0.00E+00 8.02E+03 1.18E+04 0.00E+00 0.00E+00 4.51E+06 3.19E+04 0.00E+00 NI-59 2.53E+04 7.62E+03 4.34E+03 0.00E+00 0.00E+00 7.67E+04 8.88E+02 0.00E+00 NI-63 3.39E+05 2.04E+04 1.16E+04 0.00E+00 0.00E+00 2.09E+05 2.42E+03 0.00E+00 CU-64 0.00E+00 1.88E+00 7.74E-01 0.00E+00 3.98E+00 9.30E+03 1.50E+04 0.00E+00 NI-65 2.39E+00 2.84E-01 1.23E-01 0.00E+00 0.00E+00 8.12E+03 5.01E+04 0.00E+00 ZN-65 1.93E+04 6.26E+04 3.11E+04 0.00E+00 3.25E+04 6.47E+05 5.14E+04 0.00E+00 ZN-69m 1.26E+01 2.58E+01 2.34E+00 0.00E+00 1.04E+01 2.67E+04 4.09E+04 0.00E+00 ZN-69 5.39E-02 9.67E-02 7.18E-03 0.00E+00 4.02E-02 1.47E+03 1.32E+04 0.00E+00 SE-79 0.00E+00 3.15E+03 5.88E+02 0.00E+00 3.46E+03 4.19E+05 4.84E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 1.33E+04 0.00E+00 0.00E+00 0.00E+00 1.40E-15 0.00E+00 BR-83 0.00E+00 0.00E+00 3.81E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 4.00E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 2.04E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.90E+05 8.82E+04 0.00E+00 0.00E+00 0.00E+00 3.04E+03 0.00E+00 RB-87 0.00E+00 1.24E+05 4.93E+04 0.00E+00 0.00E+00 0.00E+00 8.37E+02 0.00E+00 RB-88 0.00E+00 5.57E+02 2.87E+02 0.00E+00 0.00E+00 0.00E+00 3.39E+02 0.00E+00 RB-89 0.00E+00 3.21E+02 2.06E+02 0.00E+00 0.00E+00 0.00E+00 6.82E+01 0.00E+00 SR-89 3.98E+05 0.00E+00 1.14E+04 0.00E+00 0.00E+00 2.03E+06 6.40E+04 0.00E+00 SR-90 4.09E+07 0.00E+00 2.59E+06 0.00E+00 0.00E+00 1.12E+07 1.31E+05 0.00E+00 Y-90 3.29E+03 0.00E+00 8.82E+01 0.00E+00 0.00E+00 2.69E+05 1.04E+05 0.00E+00 SR-91 9.56E+01 0.00E+00 3.46E+00 0.00E+00 0.00E+00 5.26E+04 7.34E+04 0.00E+00 Y-91m 4.07E-01 0.00E+00 1.39E-02 0.00E+00 0.00E+00 2.79E+03 2.35E+03 0.00E+00 Y-91 5.88E+05 0.00E+00 1.57E+04 0.00E+00 0.00E+00 2.45E+06 7.03E+04 0.00E+00 II.4-99 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-24 (Page 2 of 4)
Infant Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 1.05E+01 0.00E+00 3.91E-01 0.00E+00 0.00E+00 2.38E+04 1.40E+05 0.00E+00 Y-92 1.64E+01 0.00E+00 4.61E-01 0.00E+00 0.00E+00 2.45E+04 1.27E+05 0.00E+00 Y-93 1.50E+02 0.00E+00 4.07E+00 0.00E+00 0.00E+00 7.64E+04 1.67E+05 0.00E+00 NB-93m 1.93E+05 5.03E+04 1.61E+04 0.00E+00 5.15E+04 2.93E+05 3.46E+03 0.00E+00 NB-95 1.57E+04 6.43E+03 3.78E+03 0.00E+00 4.72E+03 4.79E+05 1.27E+04 0.00E+00 NB-97 3.42E-01 7.29E-02 2.63E-02 0.00E+00 5.70E-02 3.32E+03 2.69E+04 0.00E+00 ZR-93 3.14E+05 1.33E+05 8.65E+04 0.00E+00 4.47E+05 1.92E+06 2.07E+04 0.00E+00 ZR-95 1.15E+05 2.79E+04 2.03E+04 0.00E+00 3.11E+04 1.75E+06 2.17E+04 0.00E+00 ZR-97 1.50E+02 2.56E+01 1.17E+01 0.00E+00 2.59E+01 1.10E+05 1.40E+05 0.00E+00 MO-93 0.00E+00 9.04E+03 3.11E+02 0.00E+00 2.16E+03 4.76E+05 5.26E+03 0.00E+00 MO-99 0.00E+00 1.65E+02 3.23E+01 0.00E+00 2.65E+02 1.35E+05 4.87E+04 0.00E+00 TC-99 2.93E+02 3.75E+02 1.24E+02 0.00E+00 3.49E+03 9.48E+05 1.09E+04 0.00E+00 TC-99m 1.40E-03 2.88E-03 3.72E-02 0.00E+00 3.11E-02 8.11E+02 2.03E+03 0.00E+00 TC-101 6.51E-05 8.23E-05 8.12E-04 0.00E+00 9.79E-04 5.84E+02 8.44E+02 0.00E+00 RU-103 2.02E+03 0.00E+00 6.79E+02 0.00E+00 4.24E+03 5.52E+05 1.61E+04 0.00E+00 RU-105 1.22E+00 0.00E+00 4.10E-01 0.00E+00 8.99E-01 1.57E+04 4.84E+04 0.00E+00 RU-106 8.68E+04 0.00E+00 1.09E+04 0.00E+00 1.07E+05 1.16E+07 1.64E+05 0.00E+00 RH-105 1.16E+01 7.57E+00 5.08E+00 0.00E+00 2.10E+01 2.91E+04 1.92E+04 0.00E+00 PD-107 0.00E+00 6.89E+01 5.75E+01 0.00E+00 3.85E+03 8.88E+04 1.03E+03 0.00E+00 PD-109 0.00E+00 5.49E+00 1.47E+00 0.00E+00 1.79E+01 2.35E+04 3.99E+04 0.00E+00 AG-110m 9.98E+03 7.22E+03 5.00E+03 0.00E+00 1.09E+04 3.67E+06 3.30E+04 0.00E+00 AG-111 5.25E+02 2.03E+02 1.09E+02 0.00E+00 4.27E+02 2.88E+05 4.23E+04 0.00E+00 CD-113m 0.00E+00 9.34E+05 3.70E+04 0.00E+00 8.12E+05 1.96E+06 2.31E+04 0.00E+00 CD-115m 0.00E+00 2.42E+05 8.67E+03 0.00E+00 1.32E+05 2.06E+06 7.03E+04 0.00E+00 SN-123 2.93E+05 5.89E+03 1.02E+04 5.98E+03 0.00E+00 3.11E+06 5.71E+04 0.00E+00 SN-125 1.41E+04 3.51E+02 8.40E+02 3.46E+02 0.00E+00 9.00E+05 1.02E+05 0.00E+00 SN-126 1.16E+06 2.02E+04 4.93E+04 5.38E+03 0.00E+00 6.90E+06 2.31E+04 0.00E+00 SB-124 3.79E+04 5.56E+02 1.20E+04 1.01E+02 0.00E+00 2.65E+06 5.91E+04 0.00E+00 SB-125 5.45E+04 4.77E+02 1.09E+04 6.23E+01 0.00E+00 1.64E+06 1.47E+04 0.00E+00 SB-126 4.31E+03 8.41E+01 1.55E+02 3.29E+01 0.00E+00 9.63E+05 7.46E+04 0.00E+00 SB-127 3.95E+02 7.06E+00 1.23E+02 5.04E+00 0.00E+00 2.16E+05 5.29E+04 0.00E+00 TE-125m 4.76E+03 1.99E+03 6.58E+02 1.62E+03 0.00E+00 4.47E+05 1.29E+04 0.00E+00 TE-127m 1.67E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.31E+06 2.73E+04 0.00E+00 TE-127 2.23E+00 9.53E-01 4.89E-01 1.85E+00 4.86E+00 1.04E+04 2.44E+04 0.00E+00 TE-129m 1.41E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 0.00E+00 TE-129 7.88E-02 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.00E+03 2.63E+04 0.00E+00 TE-133m 8.58E-02 5.03E-02 3.84E-02 7.73E-02 2.41E-01 5.49E+03 2.23E+04 0.00E+00 II.4-100 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-24 (Page 3 of 4)
Infant Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 4.45E-02 2.86E-02 2.35E-02 4.07E-02 1.34E-01 4.10E+03 3.54E+03 0.00E+00 I-129 3.02E+04 2.23E+04 1.62E+04 1.46E+07 2.63E+04 0.00E+00 2.97E+02 0.00E+00 I-130 6.36E+03 1.39E+04 5.57E+03 1.60E+06 1.53E+04 0.00E+00 1.99E+03 0.00E+00 I-131 3.79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 0.00E+00 1.06E+03 0.00E+00 TE-131m 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+05 1.19E+05 0.00E+00 TE-131 1.74E-02 8.22E-03 5.00E-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 0.00E+00 I-132 1.69E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 0.00E+00 1.90E+03 0.00E+00 TE-132 3.72E+02 2.37E+02 1.76E+02 2.79E+02 1.04E+03 3.40E+05 4.41E+04 0.00E+00 I-133 1.32E+04 1.92E+04 5.60E+03 3.56E+06 2.24E+04 0.00E+00 2.16E+03 0.00E+00 CS-134m 1.85E+02 2.94E+02 1.55E+02 0.00E+00 1.19E+02 2.80E+01 1.62E+02 0.00E+00 CS-134 3.96E+05 7.03E+05 7.45E+04 0.00E+00 1.90E+05 7.97E+04 1.33E+03 0.00E+00 I-134 9.21E+02 1.88E+03 6.65E+02 4.45E+04 2.09E+03 0.00E+00 1.29E+03 0.00E+00 I-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 0.00E+00 1.83E+03 0.00E+00 CS-135 1.40E+05 1.21E+05 6.62E+03 0.00E+00 3.61E+04 1.41E+04 3.05E+02 0.00E+00 CS-136 4.83E+04 1.35E+05 5.29E+04 0.00E+00 5.64E+04 1.18E+04 1.43E+03 0.00E+00 CS-137 5.49E+05 6.12E+05 4.55E+04 0.00E+00 1.72E+05 7.13E+04 1.33E+03 0.00E+00 CS-138 5.05E+02 7.81E+02 3.98E+02 0.00E+00 4.10E+02 6.54E+01 8.76E+02 0.00E+00 CS-139 3.25E+02 4.24E+02 1.71E+02 0.00E+00 2.31E+02 3.54E+01 1.86E+01 0.00E+00 BA-139 1.48E+00 9.84E-04 4.30E-02 0.00E+00 5.92E-04 5.95E+03 5.10E+04 0.00E+00 BA-140 5.60E+04 5.60E+01 2.90E+03 0.00E+00 1.34E+01 1.60E+06 3.84E+04 0.00E+00 LA-140 5.05E+02 2.00E+02 5.15E+01 0.00E+00 0.00E+00 1.68E+05 8.48E+04 0.00E+00 BA-141 1.57E-01 1.08E-04 4.97E-03 0.00E+00 6.50E-05 2.97E+03 4.75E+03 0.00E+00 LA-141 6.79E+00 1.96E+00 3.43E-01 0.00E+00 0.00E+00 1.71E+04 8.34E+04 0.00E+00 CE-141 2.77E+04 1.67E+04 1.99E+03 0.00E+00 5.25E+03 5.17E+05 2.16E+04 0.00E+00 BA-142 3.98E-02 3.30E-05 1.96E-03 0.00E+00 1.90E-05 1.55E+03 6.93E+02 0.00E+00 LA-142 1.03E+00 3.77E-01 9.04E-02 0.00E+00 0.00E+00 8.22E+03 5.95E+04 0.00E+00 CE-143 2.93E+02 1.93E+02 2.21E+01 0.00E+00 5.64E+01 1.16E+05 4.97E+04 0.00E+00 PR-143 1.40E+04 5.24E+03 6.99E+02 0.00E+00 1.97E+03 4.33E+05 3.72E+04 0.00E+00 CE-144 3.19E+06 1.21E+06 1.76E+05 0.00E+00 5.38E+05 9.84E+06 1.48E+05 0.00E+00 PR-144 4.79E-02 1.85E-02 2.41E-03 0.00E+00 6.72E-03 1.61E+03 4.28E+03 0.00E+00 ND-147 7.94E+03 8.13E+03 5.00E+02 0.00E+00 3.15E+03 3.22E+05 3.12E+04 0.00E+00 PM-147 5.47E+05 4.30E+04 2.18E+04 0.00E+00 6.90E+04 6.37E+05 8.05E+03 0.00E+00 PM-148m 7.00E+04 1.74E+04 1.39E+04 0.00E+00 2.03E+04 1.71E+06 4.72E+04 0.00E+00 PM-148 4.68E+03 6.75E+01 3.42E+02 0.00E+00 8.06E+02 4.48E+05 8.46E+04 0.00E+00 PM-149 4.34E+02 5.71E+01 2.49E+01 0.00E+00 6.94E+01 9.10E+04 4.21E+04 0.00E+00 PM-151 1.05E+02 1.54E+01 7.77E+00 0.00E+00 1.82E+01 4.55E+04 3.61E+04 0.00E+00 SM-151 4.73E+05 9.03E+04 2.28E+04 0.00E+00 7.34E+04 4.17E+05 4.84E+03 0.00E+00 II.4-101 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-24 (Page 4 of 4)
Infant Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 2.14E+02 1.65E+02 1.27E+01 0.00E+00 3.46E+01 5.18E+04 2.70E+04 0.00E+00 EU-152 1.10E+06 2.48E+05 2.41E+05 0.00E+00 8.32E+05 2.07E+06 1.38E+04 0.00E+00 EU-154 4.14E+06 4.84E+05 3.43E+05 0.00E+00 1.60E+06 4.27E+06 3.98E+04 0.00E+00 EU-155 8.36E+05 8.01E+04 4.84E+04 0.00E+00 2.21E+05 7.28E+05 7.27E+04 0.00E+00 EU-156 2.18E+04 1.34E+04 2.16E+03 0.00E+00 6.27E+03 8.57E+05 5.80E+04 0.00E+00 TB-160 1.57E+05 0.00E+00 1.96E+04 0.00E+00 4.48E+04 1.55E+06 3.00E+04 0.00E+00 HO-166m 2.03E+05 4.30E+05 3.51E+05 0.00E+00 5.91E+05 2.87E+06 2.31E+04 0.00E+00 W-181 6.80E+01 2.04E+01 2.34E+00 0.00E+00 0.00E+00 1.86E+04 3.68E+02 0.00E+00 W-185 2.20E+03 6.76E+02 7.81E+01 0.00E+00 0.00E+00 6.27E+05 1.57E+04 0.00E+00 W-187 1.30E+01 9.02E+00 3.12E+00 0.00E+00 0.00E+00 3.96E+04 3.56E+04 0.00E+00 NP-239 3.71E+02 3.32E+01 1.88E+01 0.00E+00 6.62E+01 5.95E+04 2.49E+04 0.00E+00 U-232 3.60E+08 0.00E+00 2.98E+07 0.00E+00 3.36E+07 2.09E+09 6.10E+04 0.00E+00 U-233 7.62E+07 0.00E+00 5.36E+06 0.00E+00 1.53E+07 4.98E+08 5.64E+04 0.00E+00 U-234 7.31E+07 0.00E+00 5.25E+06 0.00E+00 1.50E+07 4.89E+08 5.53E+04 0.00E+00 U-235 7.01E+07 0.00E+00 4.93E+06 0.00E+00 1.41E+07 4.59E+08 7.03E+04 0.00E+00 U-236 7.01E+07 0.00E+00 5.04E+06 0.00E+00 1.44E+07 4.69E+08 5.19E+04 0.00E+00 U-237 4.55E+02 0.00E+00 1.21E+02 0.00E+00 1.13E+03 1.28E+05 1.83E+04 0.00E+00 U-238 6.71E+07 0.00E+00 4.61E+06 0.00E+00 1.32E+07 4.28E+08 4.96E+04 0.00E+00 NP-237 4.03E+09 2.39E+09 1.76E+08 0.00E+00 1.08E+09 4.89E+08 7.14E+04 0.00E+00 NP-238 3.74E+03 8.47E+02 5.82E+01 0.00E+00 2.06E+02 1.29E+05 3.61E+04 0.00E+00 PU-238 3.77E+09 2.35E+09 1.78E+08 0.00E+00 6.50E+08 1.26E+09 6.57E+04 0.00E+00 PU-239 4.10E+09 2.46E+09 1.88E+08 0.00E+00 6.93E+08 1.19E+09 5.99E+04 0.00E+00 PU-240 4.10E+09 2.45E+09 1.88E+08 0.00E+00 6.92E+08 1.19E+09 6.10E+04 0.00E+00 PU-241 1.18E+08 2.59E+07 4.35E+06 0.00E+00 1.61E+07 1.07E+06 1.26E+03 0.00E+00 PU-242 3.81E+09 2.37E+09 1.81E+08 0.00E+00 6.68E+08 1.14E+09 5.88E+04 0.00E+00 PU-244 4.44E+09 2.72E+09 2.07E+08 0.00E+00 7.64E+08 1.31E+09 8.76E+04 0.00E+00 AM-241 4.41E+09 2.73E+09 1.83E+08 0.00E+00 1.11E+09 5.68E+08 6.69E+04 0.00E+00 AM-242m 4.55E+09 2.60E+09 1.89E+08 0.00E+00 1.12E+09 2.30E+08 8.41E+04 0.00E+00 AM-243 4.34E+09 2.63E+09 1.78E+08 0.00E+00 1.08E+09 5.39E+08 7.84E+04 0.00E+00 CM-242 1.79E+08 1.21E+08 7.98E+06 0.00E+00 2.37E+07 4.16E+08 7.14E+04 0.00E+00 CM-243 3.46E+09 2.13E+09 1.48E+08 0.00E+00 5.47E+08 5.94E+08 7.03E+04 0.00E+00 CM-244 2.90E+09 1.78E+09 1.24E+08 0.00E+00 4.49E+08 5.71E+08 6.80E+04 0.00E+00 CM-245 4.51E+09 2.74E+09 1.90E+08 0.00E+00 7.32E+08 5.49E+08 6.34E+04 0.00E+00 CM-246 4.48E+09 2.74E+09 1.90E+08 0.00E+00 7.32E+08 5.59E+08 6.23E+04 0.00E+00 CM-247 4.35E+09 2.70E+09 1.86E+08 0.00E+00 7.21E+08 5.49E+08 8.19E+04 0.00E+00 CM-248 3.61E+10 2.23E+10 1.54E+09 0.00E+00 5.94E+09 4.52E+09 1.32E+06 0.00E+00 CF-252 3.32E+09 0.00E+00 1.41E+08 0.00E+00 0.00E+00 1.92E+09 2.59E+05 0.00E+00 II.4-102 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-25 (Page 1 of 4)
Child Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 0.00E+00 C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 0.00E+00 NA-22 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 0.00E+00 NA-24 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 0.00E+00 P-32 2.61E+06 1.14E+05 9.88E+04 0.00E+00 0.00E+00 0.00E+00 4.22E+04 0.00E+00 CA-41 2.61E+05 0.00E+00 2.85E+04 0.00E+00 0.00E+00 2.67E+08 1.09E+03 0.00E+00 SC-46 7.29E+05 9.99E+05 3.85E+05 0.00E+00 8.84E+05 0.00E+00 9.07E+04 0.00E+00 CR-51 0.00E+00 0.00E+00 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 0.00E+00 MN-54 0.00E+00 4.29E+04 9.51E+03 0.00E+00 1.00E+04 1.58E+06 2.29E+04 0.00E+00 FE-55 4.74E+04 2.52E+04 7.77E+03 0.00E+00 0.00E+00 1.11E+05 2.87E+03 0.00E+00 MN-56 0.00E+00 1.66E+00 3.12E-01 0.00E+00 1.67E+00 1.31E+04 1.23E+05 0.00E+00 CO-57 0.00E+00 9.03E+02 1.07E+03 0.00E+00 0.00E+00 5.07E+05 1.32E+04 0.00E+00 CO-58 0.00E+00 1.77E+03 3.16E+03 0.00E+00 0.00E+00 1.11E+06 3.44E+04 0.00E+00 FE-59 2.07E+04 3.35E+04 1.67E+04 0.00E+00 0.00E+00 1.27E+06 7.07E+04 0.00E+00 CO-60 0.00E+00 1.31E+04 2.26E+04 0.00E+00 0.00E+00 7.07E+06 9.62E+04 0.00E+00 NI-59 6.14E+04 1.73E+04 1.05E+04 0.00E+00 0.00E+00 1.01E+05 2.33E+03 0.00E+00 NI-63 8.21E+05 4.63E+04 2.80E+04 0.00E+00 0.00E+00 2.75E+05 6.33E+03 0.00E+00 CU-64 0.00E+00 1.99E+00 1.07E+00 0.00E+00 6.03E+00 9.58E+03 3.67E+04 0.00E+00 NI-65 2.99E+00 2.96E-01 1.64E-01 0.00E+00 0.00E+00 8.18E+03 8.40E+04 0.00E+00 ZN-65 4.26E+04 1.13E+05 7.03E+04 0.00E+00 7.14E+04 9.95E+05 1.63E+04 0.00E+00 ZN-69m 1.58E+01 2.69E+01 3.18E+00 0.00E+00 1.56E+01 2.72E+04 1.00E+05 0.00E+00 ZN-69 6.70E-02 9.66E-02 8.92E-03 0.00E+00 5.85E-02 1.42E+03 1.02E+04 0.00E+00 SE-79 0.00E+00 4.55E+03 9.62E+02 0.00E+00 6.33E+03 5.51E+05 1.27E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 2.09E+04 0.00E+00 0.00E+00 0.00E+00 3.70E-15 0.00E+00 BR-83 0.00E+00 0.00E+00 4.74E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 5.48E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 2.53E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.98E+05 1.14E+05 0.00E+00 0.00E+00 0.00E+00 7.99E+03 0.00E+00 RB-87 0.00E+00 1.17E+05 5.07E+04 0.00E+00 0.00E+00 0.00E+00 1.10E+03 0.00E+00 RB-88 0.00E+00 5.62E+02 3.66E+02 0.00E+00 0.00E+00 0.00E+00 1.72E+01 0.00E+00 RB-89 0.00E+00 3.45E+02 2.90E+02 0.00E+00 0.00E+00 0.00E+00 1.89E+00 0.00E+00 SR-89 5.99E+05 0.00E+00 1.72E+04 0.00E+00 0.00E+00 2.16E+06 1.67E+05 0.00E+00 SR-90 1.01E+08 0.00E+00 6.44E+06 0.00E+00 0.00E+00 1.48E+07 3.43E+05 0.00E+00 Y-90 4.11E+03 0.00E+00 1.11E+02 0.00E+00 0.00E+00 2.62E+05 2.68E+05 0.00E+00 SR-91 1.21E+02 0.00E+00 4.59E+00 0.00E+00 0.00E+00 5.33E+04 1.74E+05 0.00E+00 Y-91m 5.07E-01 0.00E+00 1.84E-02 0.00E+00 0.00E+00 2.81E+03 1.72E+03 0.00E+00 Y-91 9.14E+05 0.00E+00 2.44E+04 0.00E+00 0.00E+00 2.63E+06 1.84E+05 0.00E+00 II.4-103 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-25 (Page 2 of 4)
Child Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 1.31E+01 0.00E+00 5.25E-01 0.00E+00 0.00E+00 2.40E+04 2.42E+05 0.00E+00 Y-92 2.04E+01 0.00E+00 5.81E-01 0.00E+00 0.00E+00 2.39E+04 2.39E+05 0.00E+00 Y-93 1.87E+02 0.00E+00 5.11E+00 0.00E+00 0.00E+00 7.44E+04 3.89E+05 0.00E+00 NB-93m 4.70E+05 1.17E+05 3.85E+04 0.00E+00 1.26E+05 3.85E+05 9.07E+03 0.00E+00 NB-95 2.35E+04 9.18E+03 6.55E+03 0.00E+00 8.62E+03 6.14E+05 3.70E+04 0.00E+00 NB-97 4.29E-01 7.70E-02 3.60E-02 0.00E+00 8.55E-02 3.42E+03 2.78E+04 0.00E+00 ZR-93 7.66E+05 2.89E+05 2.05E+05 0.00E+00 1.11E+06 2.63E+06 5.44E+04 0.00E+00 ZR-95 1.90E+05 4.18E+04 3.70E+04 0.00E+00 5.96E+04 2.23E+06 6.11E+04 0.00E+00 ZR-97 1.88E+02 2.72E+01 1.60E+01 0.00E+00 3.89E+01 1.13E+05 3.51E+05 0.00E+00 MO-93 0.00E+00 1.39E+04 5.00E+02 0.00E+00 3.92E+03 6.29E+05 1.40E+04 0.00E+00 MO-99 0.00E+00 1.72E+02 4.26E+01 0.00E+00 3.92E+02 1.35E+05 1.27E+05 0.00E+00 TC-99 4.96E+02 5.51E+02 1.98E+02 0.00E+00 6.48E+03 1.25E+06 2.87E+04 0.00E+00 TC-99m 1.78E-03 3.48E-03 5.77E-02 0.00E+00 5.07E-02 9.51E+02 4.81E+03 0.00E+00 TC-101 8.10E-05 8.51E-05 1.08E-03 0.00E+00 1.45E-03 5.85E+02 1.63E+01 0.00E+00 RU-103 2.79E+03 0.00E+00 1.07E+03 0.00E+00 7.03E+03 6.62E+05 4.48E+04 0.00E+00 RU-105 1.53E+00 0.00E+00 5.55E-01 0.00E+00 1.34E+00 1.59E+04 9.95E+04 0.00E+00 RU-106 1.36E+05 0.00E+00 1.69E+04 0.00E+00 1.84E+05 1.43E+07 4.29E+05 0.00E+00 RH-105 1.45E+01 7.77E+00 6.62E+00 0.00E+00 3.10E+01 2.89E+04 4.92E+04 0.00E+00 PD-107 0.00E+00 9.81E+02 9.29E+01 0.00E+00 7.29E+03 1.17E+05 2.69E+03 0.00E+00 PD-109 0.00E+00 5.48E+00 1.83E+00 0.00E+00 2.61E+01 2.28E+04 9.58E+04 0.00E+00 AG-110m 1.69E+04 1.14E+04 9.14E+03 0.00E+00 2.12E+04 5.48E+06 1.00E+05 0.00E+00 AG-111 6.70E+02 2.10E+02 1.39E+02 0.00E+00 6.33E+02 2.86E+05 1.10E+05 0.00E+00 CD-113m 0.00E+00 1.82E+06 7.84E+04 0.00E+00 1.90E+06 2.57E+06 6.03E+04 0.00E+00 CD-115m 0.00E+00 2.92E+05 1.25E+04 0.00E+00 2.19E+05 2.17E+06 1.84E+05 0.00E+00 SN-123 4.77E+05 7.92E+03 1.55E+04 8.40E+03 0.00E+00 3.55E+06 1.50E+05 0.00E+00 SN-125 1.83E+04 3.68E+02 1.09E+03 3.81E+02 0.00E+00 8.99E+05 2.65E+05 0.00E+00 SN-126 2.31E+06 3.85E+04 8.73E+04 1.05E+04 0.00E+00 1.12E+07 6.03E+04 0.00E+00 SB-124 5.66E+06 7.40E+02 2.00E+04 1.26E+02 0.00E+00 3.24E+06 1.64E+05 0.00E+00 SB-125 9.84E+04 7.59E+02 1.99E+04 9.10E+01 0.00E+00 2.32E+06 4.03E+04 0.00E+00 SB-126 6.36E+03 9.69E+01 2.28E+03 3.70E+01 0.00E+00 1.06E+06 2.10E+05 0.00E+00 SB-127 5.03E+02 7.73E+00 1.74E+02 5.59E+00 0.00E+00 2.28E+05 1.41E+05 0.00E+00 TE-125m 6.73E+03 2.33E+03 9.14E+02 1.92E+03 0.00E+00 4.77E+05 3.38E+04 0.00E+00 TE-127m 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 0.00E+00 TE-127 2.77E+00 9.51E-01 6.11E-01 1.96E+00 7.07E+00 1.00E+04 5.62E+04 0.00E+00 TE-129m 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 0.00E+00 TE-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 0.00E+00 TE-133m 1.08E-01 5.59E-02 5.55E-02 8.58E-02 3.74E-01 5.92E+03 1.76E+04 0.00E+00 II.4-104 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-25 (Page 3 of 4)
Child Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 5.66E-02 3.26E-02 3.48E-02 4.59E-02 2.11E-01 4.55E+03 1.80E+03 0.00E+00 I-129 3.89E+04 2.37E+04 2.11E+04 1.58E+07 4.00E+04 0.00E+00 7.96E+02 0.00E+00 I-130 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 0.00E+00 5.11E+03 0.00E+00 I-131 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 0.00E+00 2.84E+03 0.00E+00 TE-131m 1.34E+02 5.92E+01 5.07E+01 9.77E+01 4.00E+02 2.06E+05 3.08E+05 0.00E+00 TE-131 2.17E-02 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 1.33E+03 0.00E+00 I-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25E+03 0.00E+00 3.20E+03 0.00E+00 TE-132 4.81E+02 2.72E+02 2.63E+02 3.18E+02 1.77E+03 3.77E+05 1.38E+05 0.00E+00 I-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 0.00E+00 5.48E+03 0.00E+00 CS-134m 2.34E+02 3.30E+02 2.26E+02 0.00E+00 1.83E+02 3.09E+01 2.93E+02 0.00E+00 CS-134 6.51E+05 1.01E+06 2.25E+05 0.00E+00 3.30E+05 1.21E+05 3.85E+03 0.00E+00 I-134 1.17E+03 2.16E+03 9.95E+02 5.07E+04 3.30E+03 0.00E+00 9.55E+02 0.00E+00 I-135 4.92E+03 8.73E+03 4.14E+03 7.92E+05 1.34E+04 0.00E+00 4.44E+03 0.00E+00 CS-135 2.31E+05 1.53E+05 1.65E+04 0.00E+00 5.66E+04 1.93E+04 8.03E+02 0.00E+00 CS-136 6.51E+04 1.71E+05 1.16E+05 0.00E+00 9.55E+04 1.45E+04 4.18E+03 0.00E+00 CS-137 9.07E+05 8.25E+05 1.28E+05 0.00E+00 2.82E+05 1.04E+05 3.62E+03 0.00E+00 CS-138 6.33E+02 8.40E+02 5.55E+02 0.00E+00 6.22E+02 6.81E+01 2.70E+02 0.00E+00 CS-139 4.03E+02 4.26E+02 2.15E+02 0.00E+00 3.36E+02 3.46E+01 2.68E-02 0.00E+00 BA-139 1.84E+00 9.84E-04 5.37E-02 0.00E+00 8.62E-04 5.77E+03 5.77E+04 0.00E+00 BA-140 7.40E+04 6.48E+01 4.33E+03 0.00E+00 2.11E+01 1.74E+06 1.02E+05 0.00E+00 LA-140 6.44E+02 2.25E+02 7.55E+01 0.00E+00 0.00E+00 1.83E+05 2.26E+05 0.00E+00 BA-141 1.96E-01 1.09E-04 6.36E-03 0.00E+00 9.47E-05 2.92E+03 2.75E+02 0.00E+00 LA-141 8.47E+00 1.96E+00 4.26E-01 0.00E+00 0.00E+00 1.66E+04 1.62E+05 0.00E+00 CE-141 3.92E+04 1.95E+04 2.90E+03 0.00E+00 8.55E+03 5.44E+05 5.66E+04 0.00E+00 BA-142 5.00E-02 3.60E-05 2.79E-03 0.00E+00 2.91E-05 1.64E+03 2.74E+00 0.00E+00 LA-142 1.30E+00 4.11E-01 1.29E-01 0.00E+00 0.00E+00 8.70E+03 7.59E+04 0.00E+00 CE-143 3.66E+02 1.99E+02 2.88E+01 0.00E+00 8.36E+01 1.15E+05 1.27E+05 0.00E+00 PR-143 1.85E+04 5.55E+03 9.14E+02 0.00E+00 3.00E+03 4.33E+05 9.73E+04 0.00E+00 CE-144 6.77E+06 2.12E+06 3.62E+05 0.00E+00 1.17E+06 1.20E+07 3.89E+05 0.00E+00 PR-144 5.96E-02 1.85E-02 3.00E-03 0.00E+00 9.77E-03 1.57E+03 1.97E+02 0.00E+00 ND-147 1.08E+04 8.73E+03 6.81E+02 0.00E+00 4.81E+03 3.28E+05 8.21E+04 0.00E+00 PM-147 1.30E+06 9.32E+04 5.03E+04 0.00E+00 1.65E+05 8.14E+05 2.11E+04 0.00E+00 PM-148m 1.22E+05 2.42E+04 2.42E+04 0.00E+00 3.60E+04 2.12E+06 1.32E+05 0.00E+00 PM-148 5.96E+03 7.18E+02 4.63E+02 0.00E+00 1.22E+03 4.59E+05 2.22E+05 0.00E+00 PM-149 5.44E+02 5.77E+01 3.13E+01 0.00E+00 1.02E+02 8.88E+04 1.08E+05 0.00E+00 PM-151 1.32E+02 1.60E+01 1.04E+01 0.00E+00 2.72E+01 4.59E+04 9.55E+04 0.00E+00 SM-151 1.16E+06 1.76E+05 5.51E+04 0.00E+00 1.81E+05 5.48E+05 1.27E+04 0.00E+00 II.4-105 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-25 (Page 4 of 4)
Child Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 2.68E+02 1.67E+02 1.61E+01 0.00E+00 5.07E+01 5.07E+04 6.92E+04 0.00E+00 EU-152 2.75E+06 5.07E+05 5.96E+05 0.00E+00 2.12E+06 3.33E+06 4.22E+04 0.00E+00 EU-154 1.01E+07 9.21E+05 8.40E+05 0.00E+00 4.03E+06 6.14E+06 1.10E+05 0.00E+00 EU-155 2.07E+06 1.50E+05 1.18E+05 0.00E+00 5.59E+05 1.03E+06 1.99E+05 0.00E+00 EU-156 2.92E+04 1.57E+04 3.24E+03 0.00E+00 1.01E+04 9.40E+05 1.57E+05 0.00E+00 TB-160 2.88E+05 0.00E+00 3.58E+04 0.00E+00 8.58E+04 1.98E+06 8.44E+04 0.00E+00 HO-166m 4.96E+06 1.04E+06 8.77E+05 0.00E+00 1.48E+06 4.18E+06 6.03E+04 0.00E+00 W-181 9.84E+01 2.41E+01 3.33E+00 0.00E+00 0.00E+00 2.11E+04 9.66E+02 0.00E+00 W-185 3.07E+03 7.70E+02 1.08E+02 0.00E+00 0.00E+00 6.88E+05 4.11E+04 0.00E+00 W-187 1.63E+01 9.66E+00 4.33E+00 0.00E+00 0.00E+00 4.11E+04 9.10E+04 0.00E+00 NP-239 4.66E+02 3.35E+01 2.35E+01 0.00E+00 9.73E+01 5.81E+04 6.40E+04 0.00E+00 U-232 8.10E+08 0.00E+00 5.77E+07 0.00E+00 6.18E+07 2.75E+09 1.60E+05 0.00E+00 U-233 1.72E+08 0.00E+00 1.04E+07 0.00E+00 2.82E+07 6.55E+08 1.48E+05 0.00E+00 U-234 1.65E+08 0.00E+00 1.02E+07 0.00E+00 2.76E+07 6.44E+08 1.45E+05 0.00E+00 U-235 1.58E+08 0.00E+00 9.58E+06 0.00E+00 2.59E+07 6.03E+08 1.84E+05 0.00E+00 U-236 1.58E+08 0.00E+00 9.81E+06 0.00E+00 2.65E+07 6.18E+08 1.36E+05 0.00E+00 U-237 5.81E+02 0.00E+00 1.54E+02 0.00E+00 1.68E+03 1.26E+05 4.77E+04 0.00E+00 U-238 1.51E+08 0.00E+00 8.95E+06 0.00E+00 2.42E+07 5.66E+08 1.30E+05 0.00E+00 NP-237 1.01E+10 5.99E+09 4.40E+08 0.00E+00 2.74E+09 6.44E+08 1.87E+05 0.00E+00 NP-238 4.66E+03 8.51E+02 7.29E+01 0.00E+00 3.02E+02 1.25E+05 9.25E+04 0.00E+00 PU-238 9.44E+09 5.92E+09 4.48E+08 0.00E+00 1.65E+09 2.25E+09 1.72E+05 0.00E+00 PU-239 1.03E+10 6.22E+09 4.74E+08 0.00E+00 1.77E+09 2.12E+09 1.57E+05 0.00E+00 PU-240 1.03E+10 6.22E+09 4.70E+08 0.00E+00 1.76E+09 2.11E+09 1.60E+05 0.00E+00 PU-241 2.94E+08 6.48E+07 1.08E+07 0.00E+00 4.07E+07 1.87E+06 3.29E+03 0.00E+00 PU-242 9.58E+09 5.99E+09 4.55E+08 0.00E+00 1.70E+09 2.04E+09 1.54E+05 0.00E+00 PU-244 1.12E+10 6.85E+09 5.22E+08 0.00E+00 1.95E+09 2.33E+09 2.29E+05 0.00E+00 AM-241 1.10E+10 6.81E+09 4.59E+08 0.00E+00 2.82E+09 7.47E+08 1.75E+05 0.00E+00 AM-242m 1.14E+10 6.51E+09 4.70E+08 0.00E+00 2.85E+09 3.01E+08 2.21E+05 0.00E+00 AM-243 1.09E+10 6.59E+09 4.44E+08 0.00E+00 2.75E+09 7.10E+08 2.05E+05 0.00E+00 CM-242 3.51E+08 2.10E+08 1.55E+07 0.00E+00 4.96E+07 4.85E+08 1.87E+05 0.00E+00 CM-243 8.58E+09 5.25E+09 3.68E+08 0.00E+00 1.38E+09 7.77E+08 1.84E+05 0.00E+00 CM-244 7.18E+09 4.37E+09 3.07E+08 0.00E+00 1.13E+09 7.47E+08 1.78E+05 0.00E+00 CM-245 1.13E+10 6.81E+09 4.74E+08 0.00E+00 1.86E+09 7.22E+08 1.66E+05 0.00E+00 CM-246 1.12E+10 6.81E+09 4.74E+08 0.00E+00 1.86E+09 7.36E+08 1.63E+05 0.00E+00 CM-247 1.09E+10 6.73E+09 4.66E+08 0.00E+00 1.83E+09 7.22E+08 2.15E+05 0.00E+00 CM-248 9.07E+10 5.55E+10 3.85E+09 0.00E+00 1.51E+10 5.96E+09 3.46E+06 0.00E+00 CF-252 8.07E+09 0.00E+00 3.45E+08 0.00E+00 0.00E+00 2.45E+09 6.81E+05 0.00E+00 II.4-106 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-26 (Page 1 of 4)
Teen Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 0.00E+00 C-14 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 0.00E+00 NA-22 1.41E+05 1.41E+05 1.41E+05 1.41E+05 1.41E+05 1.41E+05 1.41E+05 0.00E+00 NA-24 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 0.00E+00 P-32 1.89E+06 1.10E+05 7.16E+04 0.00E+00 0.00E+00 0.00E+00 9.28E+04 0.00E+00 CA-41 3.24E+05 0.00E+00 3.50E+04 0.00E+00 1.08E+06 8.08E+08 2.38E+05 0.00E+00 SC-46 5.79E+05 1.13E+06 3.34E+05 7.50E+01 3.07E+01 2.10E+04 3.00E+03 0.00E+00 CR-51 0.00E+00 0.00E+00 1.35E+02 7.50E+01 3.07E+01 2.10E+04 3.00E+03 0.00E+00 MN-54 0.00E+00 5.11E+04 8.40E+03 0.00E+00 1.27E+04 1.98E+06 6.68E+04 0.00E+00 FE-55 3.34E+04 2.38E+04 5.54E+03 0.00E+00 0.00E+00 1.24E+05 6.39E+03 0.00E+00 MN-56 0.00E+00 1.70E+00 2.52E-01 0.00E+00 1.79E+00 1.52E+04 5.74E+04 0.00E+00 CO-57 0.00E+00 9.44E+02 9.20E+02 0.00E+00 0.00E+00 5.86E+05 3.14E+04 0.00E+00 CO-58 0.00E+00 2.07E+03 2.78E+03 0.00E+00 0.00E+00 1.34E+06 9.52E+04 0.00E+00 FE-59 1.59E+04 3.70E+04 1.43E+04 0.00E+00 0.00E+00 1.53E+06 1.78E+05 0.00E+00 CO-60 0.00E+00 1.51E+04 1.98E+04 0.00E+00 0.00E+00 8.72E+06 2.59E+05 0.00E+00 NI-59 4.35E+04 1.62E+04 7.39E+03 0.00E+00 0.00E+00 1.13E+05 5.18E+03 0.00E+00 NI-63 5.80E+05 4.34E+04 1.98E+04 0.00E+00 0.00E+00 3.07E+05 1.42E+04 0.00E+00 CU-64 0.00E+00 2.03E+00 8.48E-01 0.00E+00 6.41E+00 1.11E+04 6.14E+04 0.00E+00 NI-65 2.18E+00 2.93E-01 1.27E-01 0.00E+00 0.00E+00 9.36E+03 3.67E+04 0.00E+00 ZN-65 3.86E+04 1.34E+05 6.24E+04 0.00E+00 8.64E+04 1.24E+06 4.66E+04 0.00E+00 ZN-69m 1.15E+01 2.47E+01 2.49E+00 0.00E+00 1.65E+01 3.14E+04 1.71E+05 0.00E+00 ZN-69 4.83E-02 9.20E-02 6.46E-03 0.00E+00 6.02E-02 1.58E+03 2.85E+02 0.00E+00 SE-79 0.00E+00 4.34E+03 6.97E+02 0.00E+00 6.50E+03 6.17E+05 2.82E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 1.82E+04 0.00E+00 0.00E+00 0.00E+00 8.00E-15 0.00E+00 BR-83 0.00E+00 0.00E+00 3.44E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 4.33E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.83E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.90E+05 8.40E+04 0.00E+00 0.00E+00 0.00E+00 1.77E+04 0.00E+00 RB-87 0.00E+00 1.12E+05 3.66E+04 0.00E+00 0.00E+00 0.00E+00 2.44E+03 0.00E+00 RB-88 0.00E+00 5.46E+02 2.72E+02 0.00E+00 0.00E+00 0.00E+00 2.92E-05 0.00E+00 RB-89 0.00E+00 3.52E+02 2.33E+02 0.00E+00 0.00E+00 0.00E+00 3.38E-07 0.00E+00 SR-89 4.34E+05 0.00E+00 1.25E+04 0.00E+00 0.00E+00 2.42E+06 3.71E+05 0.00E+00 SR-90 1.08E+08 0.00E+00 6.68E+06 0.00E+00 0.00E+00 1.65E+07 7.65E+05 0.00E+00 Y-90 2.98E+03 0.00E+00 8.00E+01 0.00E+00 0.00E+00 2.93E+05 5.59E+05 0.00E+00 SR-91 8.80E+01 0.00E+00 3.51E+00 0.00E+00 0.00E+00 6.07E+04 2.59E+05 0.00E+00 Y-91m 3.70E-01 0.00E+00 1.42E-02 0.00E+00 0.00E+00 3.20E+03 3.02E+01 0.00E+00 Y-91 6.61E+05 0.00E+00 1.77E+04 0.00E+00 0.00E+00 2.94E+06 4.09E+05 0.00E+00 II.4-107 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-26 (Page 2 of 4)
Teen Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 9.52E+00 0.00E+00 4.06E-01 0.00E+00 0.00E+00 2.74E+04 1.19E+05 0.00E+00 Y-92 1.47E+01 0.00E+00 4.29E-01 0.00E+00 0.00E+00 2.68E+04 1.65E+05 0.00E+00 Y-93 1.35E+02 0.00E+00 3.72E+00 0.00E+00 0.00E+00 8.32E+04 5.79E+05 0.00E+00 NB-93m 3.31E+05 1.09E+05 2.73E+04 0.00E+00 1.27E+05 4.29E+05 2.02E+04 0.00E+00 NB-95 1.86E+04 1.03E+04 5.66E+03 0.00E+00 1.00E+04 7.51E+05 9.68E+04 0.00E+00 NB-97 3.14E-01 7.78E-02 2.84E-02 0.00E+00 9.12E-02 3.93E+03 2.17E+03 0.00E+00 ZR-93 5.46E+05 2.70E+05 1.47E+05 0.00E+00 9.28E+05 2.94E+06 1.28E+05 0.00E+00 ZR-95 1.46E+05 4.58E+04 3.15E+04 0.00E+00 6.74E+04 2.69E+06 1.49E+05 0.00E+00 ZR-97 1.38E+02 2.72E+01 1.26E+01 0.00E+00 4.12E+01 1.30E+05 6.30E+05 0.00E+00 MO-93 0.00E+00 1.33E+04 3.62E+02 0.00E+00 4.05E+03 7.05E+05 3.19E+04 0.00E+00 MO-99 0.00E+00 1.69E+02 3.22E+01 0.00E+00 4.11E+02 1.54E+05 2.69E+05 0.00E+00 TC-99 3.58E+02 5.26E+02 1.43E+02 0.00E+00 6.68E+03 1.39E+06 6.39E+04 0.00E+00 TC-99m 1.38E-03 3.86E-03 4.99E-02 0.00E+00 5.76E-02 1.15E+03 6.13E+03 0.00E+00 TC-101 5.92E-05 8.40E-05 8.24E-04 0.00E+00 1.52E-03 6.67E+02 8.72E-07 0.00E+00 RU-103 2.10E+03 0.00E+00 8.96E+02 0.00E+00 7.43E+03 7.83E+05 1.09E+05 0.00E+00 RU-105 1.12E+00 0.00E+00 4.34E-01 0.00E+00 1.41E+00 1.82E+04 9.04E+04 0.00E+00 RU-106 9.84E+04 0.00E+00 1.24E+04 0.00E+00 1.90E+05 1.61E+07 9.60E+05 0.00E+00 RH-105 1.06E+01 7.58E+00 4.99E+00 0.00E+00 3.23E+01 3.27E+04 9.84E+04 0.00E+00 PD-107 0.00E+00 9.36E+02 6.71E+01 0.00E+00 7.51E+03 1.30E+05 5.99E+03 0.00E+00 PD-109 0.00E+00 5.25E+00 1.33E+00 0.00E+00 2.69E+01 2.55E+04 1.57E+05 0.00E+00 AG-110m 1.38E+04 1.31E+04 7.99E+03 0.00E+00 2.50E+04 6.75E+06 2.73E+05 0.00E+00 AG-111 4.86E+02 2.02E+02 1.02E+02 0.00E+00 6.54E+02 3.20E+05 2.40E+05 0.00E+00 CD-113m 0.00E+00 1.74E+06 5.68E+04 0.00E+00 1.94E+06 2.87E+06 1.34E+05 0.00E+00 CD-115m 0.00E+00 2.78E+05 9.12E+03 0.00E+00 2.26E+05 2.42E+06 4.08E+05 0.00E+00 SN-123 3.45E+05 7.55E+03 1.12E+04 6.04E+03 0.00E+00 3.97E+05 3.33E+05 0.00E+00 SN-125 1.33E+04 3.54E+02 7.99E+02 2.76E+02 0.00E+00 1.01E+06 5.83E+05 0.00E+00 SN-126 1.74E+06 4.31E+04 6.59E+04 1.14E+04 0.00E+00 1.38E+07 1.34E+05 0.00E+00 SB-124 4.30E+04 7.94E+02 1.68E+04 9.76E+01 0.00E+00 3.85E+06 3.98E+05 0.00E+00 SB-125 7.38E+04 8.08E+02 1.72E+04 7.04E+01 0.00E+00 2.74E+06 9.92E+04 0.00E+00 SB-126 4.95E+03 1.02E+02 1.78E+03 2.80E+01 0.00E+00 1.24E+06 4.81E+05 0.00E+00 SB-127 3.71E+02 7.94E+00 1.40E+02 4.17E+00 0.00E+00 2.65E+05 3.15E+05 0.00E+00 TE-125m 4.88E+03 2.24E+03 6.67E+02 1.40E+03 0.00E+00 5.36E+05 7.50E+04 0.00E+00 TE-127m 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 0.00E+00 TE-127 2.01E+00 9.12E-01 4.42E-01 1.42E+00 7.28E+00 1.12E+04 8.08E+04 0.00E+00 TE-129m 1.39E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06 4.05E+05 0.00E+00 TE-129 7.10E-02 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 1.62E+03 0.00E+00 TE-133m 8.08E-02 5.86E-02 4.57E-02 6.54E-02 2.46E-01 6.97E+03 9.84E+02 0.00E+00 II.4-108 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-26 (Page 3 of 4)
Teen Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 4.25E-02 3.48E-02 2.91E-02 3.57E-02 2.33E-01 5.38E+03 1.10E+01 0.00E+00 I-129 2.82E+04 2.35E+04 7.12E+04 2.93E+07 4.21E+04 0.00E+00 1.83E+03 0.00E+00 I-130 6.24E+03 1.79E+04 7.17E+03 1.49E+06 2.75E+04 0.00E+00 9.12E+03 0.00E+00 I-131 3.54E+04 4.91E+04 2.64E+04 1.46E+07 8.40E+04 0.00E+00 6.49E+03 0.00E+00 TE-131m 9.84E+01 6.01E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 6.21E+05 0.00E+00 TE-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51E+01 0.00E+00 I-132 1.59E+03 4.38E+03 1.58E+03 1.51E+05 6.92E+03 0.00E+00 1.27E+03 0.00E+00 TE-132 3.60E+02 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 0.00E+00 I-133 1.22E+04 2.05E+04 6.22E+03 2.92E+06 3.59E+04 0.00E+00 1.03E+04 0.00E+00 CS-134m 1.76E+02 3.48E+02 1.88E+02 0.00E+00 2.03E+02 3.65E+01 1.62E+02 0.00E+00 CS-134 5.02E+05 1.13E+06 5.49E+05 0.00E+00 3.75E+05 1.46E+05 9.76E+03 0.00E+00 I-134 8.88E+02 2.32E+03 8.40E+02 3.95E+04 3.66E+03 0.00E+00 2.04E+01 0.00E+00 I-135 3.70E+03 9.44E+03 3.49E+03 6.21E+05 1.49E+04 0.00E+00 6.95E+03 0.00E+00 CS-135 1.66E+05 1.46E+05 3.58E+04 0.00E+00 5.84E+04 2.16E+04 1.78E+03 0.00E+00 CS-136 5.15E+04 1.94E+05 1.37E+05 0.00E+00 1.10E+05 1.78E+04 1.09E+04 0.00E+00 CS-137 6.70E+05 8.48E+05 3.11E+05 0.00E+00 3.04E+05 1.21E+05 8.48E+03 0.00E+00 CS-138 4.66E+02 8.56E+02 4.46E+02 0.00E+00 6.62E+02 7.87E+01 2.70E-01 0.00E+00 CS-139 2.92E+02 4.10E+02 1.58E+02 0.00E+00 3.47E+02 3.89E+01 1.33E-13 0.00E+00 BA-139 1.34E+00 9.44E-04 3.90E-02 0.00E+00 8.88E-04 6.46E+03 6.45E+03 0.00E+00 BA-140 5.47E+04 6.70E+01 3.52E+03 0.00E+00 2.28E+01 2.03E+06 2.29E+05 0.00E+00 LA-140 4.79E+02 2.36E+02 6.26E+01 0.00E+00 0.00E+00 2.14E+05 4.87E+05 0.00E+00 BA-141 1.42E-01 1.06E-04 4.74E-03 0.00E+00 9.84E-05 3.29E+03 7.46E-04 0.00E+00 LA-141 6.10E+00 1.88E+00 3.10E-01 0.00E+00 0.00E+00 1.85E+04 1.23E+05 0.00E+00 CE-141 2.84E+04 1.90E+04 2.17E+03 0.00E+00 8.88E+03 6.14E+05 1.26E+05 0.00E+00 BA-142 3.70E-02 3.70E-05 2.27E-03 0.00E+00 3.14E-05 1.91E+03 4.79E-10 0.00E+00 LA-142 9.60E-01 4.25E-01 1.06E-01 0.00E+00 0.00E+00 1.02E+04 1.20E+04 0.00E+00 CE-143 2.66E+02 1.94E+02 2.16E+01 0.00E+00 8.64E+01 1.30E+05 2.55E+05 0.00E+00 PR-143 1.34E+04 5.31E+03 6.62E+02 0.00E+00 3.09E+03 4.83E+05 2.14E+05 0.00E+00 CE-144 4.89E+06 2.02E+06 2.62E+05 0.00E+00 1.21E+06 1.34E+07 8.64E+05 0.00E+00 PR-144 4.30E-02 1.76E-02 2.18E-03 0.00E+00 1.01E-02 1.75E+03 2.35E-04 0.00E+00 ND-147 7.86E+03 8.56E+03 5.13E+02 0.00E+00 5.02E+03 3.72E+05 1.82E+05 0.00E+00 PM-147 9.20E+05 8.80E+04 3.60E+04 0.00E+00 1.68E+05 9.12E+05 4.70E+04 0.00E+00 PM-148m 1.06E+05 2.68E+04 2.10E+04 0.00E+00 4.06E+04 2.56E+06 3.28E+05 0.00E+00 PM-148 4.35E+03 7.10E+02 3.58E+02 0.00E+00 1.28E+03 5.22E+05 4.91E+05 0.00E+00 PM-149 3.93E+02 5.51E+01 2.27E+01 0.00E+00 1.05E+02 9.92E+04 2.23E+05 0.00E+00 PM-151 9.60E+01 1.59E+01 8.08E+00 0.00E+00 2.86E+01 4.52E+04 1.82E+05 0.00E+00 SM-151 8.56E+05 1.68E+05 3.89E+04 0.00E+00 1.82E+05 6.14E+05 2.82E+04 0.00E+00 II.4-109 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-26 (Page 4 of 4)
Teen Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.94E+02 1.61E+02 1.18E+01 0.00E+00 5.25E+01 5.69E+04 1.42E+05 0.00E+00 EU-152 2.37E+06 5.75E+05 5.04E+05 0.00E+00 2.67E+06 4.01E+06 1.08E+05 0.00E+00 EU-154 7.54E+06 9.84E+05 6.88E+05 0.00E+00 4.35E+06 7.30E+06 2.67E+05 0.00E+00 EU-155 1.60E+06 1.57E+05 9.68E+04 0.00E+00 6.12E+05 1.21E+07 4.78E+05 0.00E+00 EU-156 2.16E+04 1.62E+04 2.64E+03 0.00E+00 1.09E+04 1.10E+06 3.65E+05 0.00E+00 TB-160 2.43E+05 0.00E+00 3.03E+04 0.00E+00 9.60E+04 3.18E+06 2.08E+05 0.00E+00 HO-166m 3.52E+06 1.25E+06 7.90E+05 0.00E+00 1.60E+06 4.99E+06 1.34E+05 0.00E+00 W-181 7.12E+01 2.30E+01 2.41E+00 0.00E+00 0.00E+00 2.36E+04 2.15E+03 0.00E+00 W-185 2.22E+03 7.34E+02 7.78E+01 0.00E+00 0.00E+00 7.68E+05 9.12E+04 0.00E+00 W-187 1.20E+01 9.76E+00 3.43E+00 0.00E+00 0.00E+00 4.74E+04 1.77E+05 0.00E+00 NP-239 3.38E+02 3.19E+01 1.77E+01 0.00E+00 1.00E+02 6.49E+04 1.32E+05 0.00E+00 U-232 5.85E+08 0.00E+00 4.18E+07 0.00E+00 6.35E+07 3.07E+09 3.57E+05 0.00E+00 U-233 1.24E+08 0.00E+00 7.54E+06 0.00E+00 2.90E+07 7.34E+08 3.30E+05 0.00E+00 U-234 1.18E+08 0.00E+00 7.38E+06 0.00E+00 2.84E+07 7.19E+08 3.23E+05 0.00E+00 U-235 1.14E+08 0.00E+00 6.94E+06 0.00E+00 2.67E+07 6.75E+08 4.10E+05 0.00E+00 U-236 1.14E+08 0.00E+00 7.09E+06 0.00E+00 2.73E+07 6.90E+08 3.03E+05 0.00E+00 U-237 4.20E+02 0.00E+00 1.12E+02 0.00E+00 1.73E+03 1.41E+05 1.03E+05 0.00E+00 U-238 1.09E+08 0.00E+00 6.48E+06 0.00E+00 2.50E+07 6.31E+08 2.90E+05 0.00E+00 NP-237 1.31E+10 8.48E+09 5.77E+08 0.00E+00 4.28E+09 7.19E+08 4.18E+05 0.00E+00 NP-238 3.38E+03 8.16E+02 5.27E+01 0.00E+00 3.10E+02 1.40E+05 1.90E+05 0.00E+00 PU-238 1.20E+10 8.24E+09 5.78E+08 0.00E+00 2.48E+09 2.50E+09 3.83E+05 0.00E+00 PU-239 1.38E+10 8.96E+09 6.44E+08 0.00E+00 2.75E+09 2.34E+09 3.50E+05 0.00E+00 PU-240 1.38E+10 8.96E+09 6.43E+08 0.00E+00 2.74E+09 2.34E+09 3.57E+05 0.00E+00 PU-241 2.99E+08 7.65E+07 1.12E+07 0.00E+00 5.18E+07 2.08E+06 7.34E+03 0.00E+00 PU-242 1.28E+10 8.64E+09 6.20E+08 0.00E+00 2.65E+09 2.26E+09 3.43E+05 0.00E+00 PU-244 1.50E+10 9.92E+09 7.10E+08 0.00E+00 3.03E+09 2.58E+09 5.11E+05 0.00E+00 AM-241 1.42E+10 9.60E+09 5.68E+08 0.00E+00 4.26E+09 8.40E+08 3.90E+05 0.00E+00 AM-242m 1.43E+10 9.04E+09 5.72E+08 0.00E+00 4.24E+09 3.37E+08 4.91E+05 0.00E+00 AM-243 1.42E+10 9.36E+09 5.56E+08 0.00E+00 4.17E+09 7.93E+08 4.58E+05 0.00E+00 CM-242 2.54E+08 2.01E+08 1.13E+07 0.00E+00 5.12E+07 5.41E+08 4.17E+05 0.00E+00 CM-243 9.52E+09 6.64E+09 4.00E+08 0.00E+00 1.87E+09 8.72E+08 4.10E+05 0.00E+00 CM-244 7.35E+09 5.22E+09 3.10E+08 0.00E+00 1.45E+09 8.40E+08 3.97E+05 0.00E+00 CM-245 1.46E+10 9.76E+09 6.02E+08 0.00E+00 2.82E+09 8.08E+08 3.70E+05 0.00E+00 CM-246 1.45E+10 9.76E+09 6.02E+08 0.00E+00 2.81E+09 8.24E+08 3.63E+05 0.00E+00 CM-247 1.42E+10 9.52E+09 5.93E+08 0.00E+00 2.77E+09 8.08E+08 4.78E+05 0.00E+00 CM-248 1.18E+11 7.86E+10 4.89E+09 0.00E+00 2.28E+10 6.66E+09 7.70E+06 0.00E+00 CF-252 5.73E+09 0.00E+00 2.46E+08 0.00E+00 0.00E+00 2.74E+09 1.51E+06 0.00E+00 II.4-110 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-27 (Page 1 of 4)
Adult Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 0.00E+00 C-14 1.82E+04 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 0.00E+00 NA-22 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 0.00E+00 NA-24 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 0.00E+00 P-32 1.32E+06 7.71E+04 5.01E+04 0.00E+00 0.00E+00 0.00E+00 8.64E+04 0.00E+00 CA-41 3.06E+05 0.00E+00 3.30E+04 0.00E+00 0.00E+00 3.06E+04 2.29E+03 0.00E+00 SC-46 4.41E+05 8.56E+05 2.49E+05 0.00E+00 7.99E+05 0.00E+00 2.58E+05 0.00E+00 CR-51 0.00E+00 0.00E+00 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 0.00E+00 MN-54 0.00E+00 3.96E+04 6.30E+03 0.00E+00 9.84E+03 1.40E+06 7.74E+04 0.00E+00 FE-55 2.46E+04 1.70E+04 3.94E+03 0.00E+00 0.00E+00 7.21E+04 6.03E+03 0.00E+00 MN-56 0.00E+00 1.24E+00 1.83E-01 0.00E+00 1.30E+00 9.44E+03 2.02E+04 0.00E+00 CO-57 0.00E+00 6.92E+02 6.71E+02 0.00E+00 0.00E+00 3.70E+05 3.14E+04 0.00E+00 CO-58 0.00E+00 1.58E+03 2.07E+03 0.00E+00 0.00E+00 9.28E+05 1.06E+05 0.00E+00 FE-59 1.18E+04 2.78E+04 1.06E+04 0.00E+00 0.00E+00 1.02E+06 1.88E+05 0.00E+00 CO-60 0.00E+00 1.15E+04 1.48E+04 0.00E+00 0.00E+00 5.97E+06 2.85E+05 0.00E+00 NI-59 3.25E+04 1.17E+04 5.42E+03 0.00E+00 0.00E+00 6.56E+04 4.89E+03 0.00E+00 NI-63 4.32E+05 3.14E+04 1.45E+04 0.00E+00 0.00E+00 1.78E+05 1.34E+04 0.00E+00 CU-64 0.00E+00 1.46E+00 6.15E-01 0.00E+00 4.62E+00 6.78E+03 4.90E+04 0.00E+00 NI-65 1.54E+00 2.10E-01 9.12E-02 0.00E+00 0.00E+00 5.60E+03 1.23E+04 0.00E+00 ZN-65 3.24E+04 1.03E+05 4.66E+04 0.00E+00 6.90E+04 8.64E+05 5.34E+04 0.00E+00 ZN-69m 8.16E+00 1.96E+01 1.79E+00 0.00E+00 1.18E+01 1.90E+04 1.37E+05 0.00E+00 ZN-69 3.38E-02 6.51E-02 4.52E-03 0.00E+00 4.22E-02 9.20E+02 1.63E+01 0.00E+00 SE-79 0.00E+00 3.06E+03 4.87E+02 0.00E+00 4.55E+03 3.58E+05 2.66E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 1.35E+04 0.00E+00 0.00E+00 0.00E+00 1.04E+04 0.00E+00 BR-83 0.00E+00 0.00E+00 2.41E+02 0.00E+00 0.00E+00 0.00E+00 2.32E+02 0.00E+00 BR-84 0.00E+00 0.00E+00 3.13E+02 0.00E+00 0.00E+00 0.00E+00 1.64E-03 0.00E+00 BR-85 0.00E+00 0.00E+00 1.28E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.35E+05 5.90E+04 0.00E+00 0.00E+00 0.00E+00 1.66E+04 0.00E+00 RB-87 0.00E+00 3.87E+02 2.57E+04 0.00E+00 0.00E+00 0.00E+00 2.30E+03 0.00E+00 RB-88 0.00E+00 3.87E+02 1.93E+02 0.00E+00 0.00E+00 0.00E+00 3.34E-09 0.00E+00 RB-89 0.00E+00 2.56E+02 1.70E+02 0.00E+00 0.00E+00 0.00E+00 9.28E-12 0.00E+00 SR-89 3.04E+05 0.00E+00 8.72E+03 0.00E+00 0.00E+00 1.40E+06 3.50E+05 0.00E+00 SR-90 9.92E+07 0.00E+00 6.10E+06 0.00E+00 0.00E+00 9.60E+06 7.22E+05 0.00E+00 Y-90 2.09E+03 0.00E+00 5.61E+01 0.00E+00 0.00E+00 1.70E+05 5.06E+05 0.00E+00 SR-91 6.19E+01 0.00E+00 2.50E+00 0.00E+00 0.00E+00 3.65E+04 1.91E+05 0.00E+00 Y-91m 2.61E-01 0.00E+00 1.02E-02 0.00E+00 0.00E+00 1.92E+03 1.33E+00 0.00E+00 Y-91 4.62E+05 0.00E+00 1.24E+04 0.00E+00 0.00E+00 1.70E+06 3.85E+05 0.00E+00 II.4-111 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-27 (Page 2 of 4)
Adult Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 6.74E+00 0.00E+00 2.91E-01 0.00E+00 0.00E+00 1.65E+04 4.30E+04 0.00E+00 Y-92 1.03E+01 0.00E+00 3.02E-01 0.00E+00 0.00E+00 1.57E+04 7.35E+04 0.00E+00 Y-93 9.44E+01 0.00E+00 2.61E+00 0.00E+00 0.00E+00 4.85E+04 4.22E+05 0.00E+00 NB-93m 2.48E+05 8.08E+04 1.99E+04 0.00E+00 9.28E+04 2.49E+05 1.90E+04 0.00E+00 NB-95 1.41E+04 7.82E+03 4.21E+03 0.00E+00 7.74E+03 5.05E+05 1.04E+05 0.00E+00 NB-97 2.22E-01 5.62E-02 2.05E-02 0.00E+00 6.54E-02 2.40E+03 2.42E+02 0.00E+00 ZR-93 4.18E+05 2.34E+04 1.10E+04 0.00E+00 8.88E+04 1.70E+05 1.21E+04 0.00E+00 ZR-95 1.07E+05 3.44E+04 2.33E+04 0.00E+00 5.42E+04 1.77E+06 1.50E+05 0.00E+00 ZR-97 9.68E+01 1.96E+01 9.04E+00 0.00E+00 2.97E+01 7.87E+04 5.23E+05 0.00E+00 MO-93 0.00E+00 9.36E+03 2.54E+02 0.00E+00 2.84E+03 4.09E+05 3.03E+04 0.00E+00 MO-99 0.00E+00 1.21E+02 2.30E+01 0.00E+00 2.91E+02 9.12E+04 2.48E+05 0.00E+00 TC-99 2.50E+02 3.71E+02 1.00E+02 0.00E+00 4.68E+03 8.08E+05 6.03E+04 0.00E+00 TC-99m 1.03E-03 2.91E-03 3.70E-02 0.00E+00 4.42E-02 7.64E+02 4.16E+03 0.00E+00 TC-101 4.18E-05 6.02E-05 5.90E-04 0.00E+00 1.08E-03 3.99E+02 1.09E-11 0.00E+00 RU-103 1.53E+03 0.00E+00 6.58E+02 0.00E+00 5.83E+03 5.05E+05 1.10E+05 0.00E+00 RU-105 7.90E-01 0.00E+00 3.11E-01 0.00E+00 1.02E+00 1.10E+04 4.82E+04 0.00E+00 RU-106 6.91E+04 0.00E+00 8.72E+03 0.00E+00 1.34E+05 9.36E+06 9.12E+05 0.00E+00 RH-105 7.39E+00 5.38E+00 3.54E+00 0.00E+00 2.29E+01 1.93E+04 8.72E+04 0.00E+00 PD-107 0.00E+00 6.62E+02 4.70E+01 0.00E+00 5.26E+03 7.58E+04 5.65E+03 0.00E+00 PD-109 0.00E+00 3.70E+00 9.28E-01 0.00E+00 1.88E+01 1.48E+04 1.22E+05 0.00E+00 AG-110m 1.08E+04 1.00E+04 5.94E+03 0.00E+00 1.97E+04 4.63E+06 3.02E+05 0.00E+00 AG-111 3.40E+02 1.42E+02 7.10E+01 0.00E+00 4.59E+02 1.86E+05 2.23E+05 0.00E+00 CD-113m 0.00E+00 1.23E+06 3.98E+04 0.00E+00 1.37E+06 1.66E+06 1.27E+05 0.00E+00 CD-115m 0.00E+00 1.97E+05 6.36E+03 0.00E+00 1.58E+05 1.41E+06 3.84E+05 0.00E+00 SN-123 2.42E+05 5.34E+03 7.86E+03 4.54E+03 0.00E+00 2.30E+06 3.14E+05 0.00E+00 SN-125 9.28E+03 2.50E+02 5.62E+02 2.07E+02 0.00E+00 5.90E+05 5.45E+05 0.00E+00 SN-126 1.26E+06 3.34E+04 4.80E+04 9.84E+03 0.00E+00 9.36E+06 1.27E+05 0.00E+00 SB-124 3.12E+04 5.89E+02 1.22E+04 7.55E+01 0.00E+00 2.48E+06 4.06E+05 0.00E+00 SB-125 5.34E+04 5.95E+02 1.26E+04 5.40E+01 0.00E+00 1.74E+06 1.01E+05 0.00E+00 SB-126 3.60E+03 7.30E+01 1.30E+03 2.20E+01 0.00E+00 7.66E+05 4.81E+05 0.00E+00 SB-127 2.64E+02 5.78E+00 1.02E+02 3.18E+00 0.00E+00 1.64E+05 3.02E+05 0.00E+00 TE-125m 3.42E+03 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 0.00E+00 TE-127m 1.26E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 0.00E+00 TE-127 1.40E+00 6.42E-01 3.10E-01 1.06E+00 5.10E+00 6.51E+03 5.74E+04 0.00E+00 TE-129m 9.76E+03 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 0.00E+00 TE-129 4.98E-02 2.39E-02 1.24E-02 3.90E-02 1.87E-01 1.94E+03 1.57E+02 0.00E+00 TE-133m 5.79E-02 4.32E-02 3.34E-02 5.02E-02 2.99E-01 4.41E+03 4.39E+02 0.00E+00 II.4-112 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-27 (Page 3 of 4)
Adult Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 3.07E-02 2.58E-02 1.26E-02 2.75E-02 1.74E-01 3.47E+03 2.38E-01 0.00E+00 I-129 1.98E+04 1.69E+04 5.53E+04 4.43E+07 3.62E+04 0.00E+00 1.78E+03 0.00E+00 I-130 4.58E+03 1.34E+04 5.28E+03 1.14E+06 2.09E+04 0.00E+00 7.69E+03 0.00E+00 I-131 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 0.00E+00 6.28E+03 0.00E+00 TE-131m 6.99E+01 4.36E+01 2.90E+01 5.50E+01 3.09E+02 1.46E+05 5.56E+05 0.00E+00 TE-131 1.11E-02 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 0.00E+00 I-132 1.16E+03 3.26E+03 1.16E+03 1.14E+05 5.18E+03 0.00E+00 4.06E+02 0.00E+00 TE-132 2.60E+02 2.15E+02 1.62E+02 1.90E+02 1.46E+03 2.88E+05 5.10E+05 0.00E+00 I-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 0.00E+00 8.88E+03 0.00E+00 CS-134m 1.27E+02 2.56E+02 1.38E+02 0.00E+00 1.46E+02 2.34E+01 6.34E+01 0.00E+00 CS-134 3.73E+05 8.48E+05 7.28E+05 0.00E+00 2.87E+05 9.76E+04 1.04E+04 0.00E+00 I-134 6.44E+02 1.73E+03 6.15E+02 2.98E+04 2.75E+03 0.00E+00 1.01E+00 0.00E+00 I-135 2.68E+03 6.98E+03 2.57E+03 4.48E+05 1.11E+04 0.00E+00 5.25E+03 0.00E+00 CS-135 1.17E+05 1.03E+05 4.79E+04 0.00E+00 4.09E+04 1.26E+04 1.69E+03 0.00E+00 CS-136 3.90E+04 1.46E+05 1.10E+05 0.00E+00 8.56E+04 1.20E+04 1.17E+04 0.00E+00 CS-137 4.78E+05 6.21E+05 4.28E+05 0.00E+00 2.22E+05 7.52E+04 8.40E+03 0.00E+00 CS-138 3.31E+02 6.21E+02 3.24E+02 0.00E+00 4.80E+02 4.86E+01 1.86E-03 0.00E+00 CS-139 2.05E+02 2.90E+02 1.11E+02 0.00E+00 2.44E+02 2.27E+01 4.39E-21 0.00E+00 BA-139 9.36E-01 6.66E-04 2.74E-02 0.00E+00 6.22E-04 3.76E+03 8.96E+02 0.00E+00 BA-140 3.90E+04 4.90E+01 2.57E+03 0.00E+00 1.67E+01 1.27E+06 2.18E+05 0.00E+00 LA-140 3.44E+02 1.74E+02 4.58E+01 0.00E+00 0.00E+00 1.36E+05 4.58E+05 0.00E+00 BA-141 1.00E-01 7.53E-05 3.36E-03 0.00E+00 7.00E-05 1.94E+03 1.16E-07 0.00E+00 LA-141 4.27E+00 1.33E+00 2.17E-01 0.00E+00 0.00E+00 1.08E+04 5.85E+04 0.00E+00 CE-141 1.99E+04 1.35E+04 1.53E+03 0.00E+00 6.26E+03 3.62E+05 1.20E+05 0.00E+00 BA-142 2.63E-02 2.70E-05 1.66E-03 0.00E+00 2.29E-05 1.19E+03 1.57E-16 0.00E+00 LA-142 6.83E-01 3.10E-01 7.72E-02 0.00E+00 0.00E+00 6.33E+03 2.11E+03 0.00E+00 CE-143 1.86E+02 1.38E+02 1.53E+01 0.00E+00 6.08E+01 7.98E+04 2.26E+05 0.00E+00 PR-143 9.36E+03 3.75E+03 4.64E+02 0.00E+00 2.16E+03 2.81E+05 2.00E+05 0.00E+00 CE-144 3.43E+06 1.43E+06 1.84E+05 0.00E+00 8.48E+05 7.78E+06 8.16E+05 0.00E+00 PR-144 3.01E-02 1.25E-02 1.53E-03 0.00E+00 7.05E-03 1.02E+03 2.15E-08 0.00E+00 ND-147 5.27E+03 6.10E+03 3.65E+02 0.00E+00 3.56E+03 2.21E+05 1.73E+05 0.00E+00 PM-147 6.70E+05 6.30E+04 2.55E+04 0.00E+00 1.19E+05 5.28E+05 4.43E+04 0.00E+00 PM-148m 7.86E+04 2.03E+04 1.55E+04 0.00E+00 3.08E+04 1.71E+06 3.34E+05 0.00E+00 PM-148 3.07E+03 5.10E+02 2.56E+02 0.00E+00 9.60E+02 3.13E+05 4.64E+05 0.00E+00 PM-149 2.75E+02 3.90E+01 1.59E+01 0.00E+00 7.35E+01 5.77E+04 2.00E+05 0.00E+00 PM-151 6.80E+01 1.14E+01 5.77E+00 0.00E+00 2.04E+01 3.15E+04 1.60E+05 0.00E+00 SM-151 6.87E+05 1.18E+05 2.84E+04 0.00E+00 1.33E+05 3.56E+05 2.60E+04 0.00E+00 II.4-113 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-27 (Page 4 of 4)
Adult Inhalation Pi mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.36E+02 1.14E+02 8.32E+00 0.00E+00 3.67E+01 3.31E+04 1.26E+05 0.00E+00 EU-152 1.90E+06 4.33E+05 3.81E+05 0.00E+00 2.68E+06 2.74E+06 1.27E+05 0.00E+00 EU-154 5.92E+06 7.28E+05 5.18E+05 0.00E+00 3.49E+06 4.67E+06 2.72E+05 0.00E+00 EU-155 8.08E+05 1.14E+05 7.37E+04 0.00E+00 5.27E+05 7.57E+05 4.76E+04 0.00E+00 EU-156 1.54E+04 1.18E+04 1.92E+03 0.00E+00 7.96E+03 6.85E+05 3.60E+05 0.00E+00 TB-160 1.77E+05 0.00E+00 2.20E+04 0.00E+00 7.28E+04 1.54E+06 2.14E+05 0.00E+00 HO-166m 2.70E+06 8.40E+05 6.40E+05 0.00E+00 1.26E+06 3.15E+06 1.27E+05 0.00E+00 W-181 4.98E+01 1.62E+01 1.74E+00 0.00E+00 0.00E+00 1.37E+04 2.02E+03 0.00E+00 W-185 1.56E+03 5.18E+02 5.45E+01 0.00E+00 0.00E+00 4.46E+05 8.56E+04 0.00E+00 W-187 8.48E+00 7.08E+00 2.48E+00 0.00E+00 0.00E+00 2.90E+04 1.55E+05 0.00E+00 NP-239 2.30E+02 2.26E+01 1.24E+01 0.00E+00 7.00E+01 3.76E+04 1.19E+05 0.00E+00 U-232 4.11E+08 0.00E+00 2.93E+07 0.00E+00 4.45E+07 1.78E+09 3.37E+05 0.00E+00 U-233 8.72E+07 0.00E+00 5.28E+06 0.00E+00 2.03E+07 4.26E+08 3.11E+05 0.00E+00 U-234 8.32E+07 0.00E+00 5.17E+06 0.00E+00 1.99E+07 4.18E+08 3.05E+05 0.00E+00 U-235 8.00E+07 0.00E+00 4.86E+06 0.00E+00 1.87E+07 3.92E+08 3.87E+05 0.00E+00 U-236 8.00E+07 0.00E+00 4.96E+06 0.00E+00 1.91E+07 4.00E+08 2.86E+05 0.00E+00 U-237 2.94E+02 0.00E+00 7.82E+01 0.00E+00 1.21E+03 8.16E+04 9.60E+04 0.00E+00 U-238 7.66E+07 0.00E+00 4.54E+06 0.00E+00 1.74E+07 3.66E+08 2.73E+05 0.00E+00 NP-237 1.25E+10 8.00E+09 5.50E+08 0.00E+00 4.08E+09 4.18E+08 3.94E+05 0.00E+00 NP-238 2.37E+03 5.76E+02 3.69E+01 0.00E+00 2.18E+02 8.16E+04 1.70E+05 0.00E+00 PU-238 1.14E+10 7.77E+09 5.52E+08 0.00E+00 2.37E+09 1.46E+09 3.62E+05 0.00E+00 PU-239 1.33E+10 8.56E+09 6.20E+08 0.00E+00 2.64E+09 1.38E+09 3.30E+05 0.00E+00 PU-240 1.32E+10 8.56E+09 6.18E+08 0.00E+00 2.63E+09 1.38E+09 3.37E+05 0.00E+00 PU-241 2.74E+08 6.95E+07 1.03E+07 0.00E+00 4.74E+07 1.22E+06 6.92E+03 0.00E+00 PU-242 1.22E+10 8.24E+09 5.97E+08 0.00E+00 2.54E+09 1.32E+09 3.24E+05 0.00E+00 PU-244 1.43E+10 9.44E+09 6.83E+08 0.00E+00 2.91E+09 1.51E+09 4.82E+05 0.00E+00 AM-241 1.34E+10 9.04E+09 5.37E+08 0.00E+00 4.03E+09 4.85E+08 3.68E+05 0.00E+00 AM-242m 1.36E+10 8.48E+09 5.38E+08 0.00E+00 4.01E+09 1.95E+08 4.63E+05 0.00E+00 AM-243 1.34E+10 8.80E+09 5.26E+08 0.00E+00 3.96E+09 4.60E+08 4.32E+05 0.00E+00 CM-242 1.78E+08 1.42E+08 7.87E+06 0.00E+00 3.58E+07 3.14E+08 3.93E+05 0.00E+00 CM-243 8.80E+09 6.09E+09 3.69E+08 0.00E+00 1.72E+09 5.05E+08 3.87E+05 0.00E+00 CM-244 6.70E+09 4.70E+09 2.81E+08 0.00E+00 1.31E+09 4.85E+08 3.74E+05 0.00E+00 CM-245 1.39E+10 9.12E+09 5.71E+08 0.00E+00 2.66E+09 4.68E+08 3.49E+05 0.00E+00 CM-246 1.38E+10 9.12E+09 5.70E+08 0.00E+00 2.66E+09 4.77E+08 3.43E+05 0.00E+00 CM-247 1.34E+10 8.96E+09 5.62E+08 0.00E+00 2.62E+09 4.68E+08 4.50E+05 0.00E+00 CM-248 1.12E+11 7.41E+10 4.63E+09 0.00E+00 2.16E+10 3.86E+09 7.27E+06 0.00E+00 CF-252 4.34E+09 0.00E+00 1.86E+08 0.00E+00 0.00E+00 1.59E+09 1.42E+06 0.00E+00 II.4-114 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-28 (Page 1 of 4)
All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C-14 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NA-22 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.31E+10 NA-24 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.39E+07 P-32 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CA-41 1.98E+10 1.98E+10 1.98E+10 1.98E+10 1.98E+10 1.98E+10 1.98E+10 2.33E+10 SC-46 8.33E+08 8.33E+08 8.33E+08 8.33E+08 8.33E+08 8.33E+08 8.33E+08 9.61E+08 CR-51 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 5.51E+06 MN-54 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.63E+09 FE-55 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MN-56 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 1.07E+06 CO-57 1.88E+08 1.88E+08 1.88E+08 1.88E+08 1.88E+08 1.88E+08 1.88E+08 2.07E+08 CO-58 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 4.44E+08 FE-59 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 3.21E+08 CO-60 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.89E+10 NI-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-63 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CU-64 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.88E+05 NI-65 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 3.45E+05 ZN-65 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 8.59E+08 ZN-69m 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.49E+06 ZN-69 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SE-79 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-82 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.47E+07 BR-83 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 7.08E+03 BR-84 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.36E+05 BR-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 1.03E+07 RB-87 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-88 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.78E+04 RB-89 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.48E+05 SR-89 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.51E+04 SR-90 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-90 4.49E+03 4.49E+03 4.49E+03 4.49E+03 4.49E+03 4.49E+03 4.49E+03 5.31E+03 SR-91 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.51E+06 Y-91m 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.16E+05 Y-91 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.21E+06 II.4-115 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-28 (Page 2 of 4)
All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 8.63E+05 Y-92 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 2.14E+05 Y-93 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 2.51E+05 NB-93m 2.54E+06 2.54E+06 2.54E+06 2.54E+06 2.54E+06 2.54E+06 2.54E+06 3.09E+08 NB-95 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.61E+08 NB-97 1.76E+05 1.76E+05 1.76E+05 1.76E+05 1.76E+05 1.76E+05 1.76E+05 2.07E+05 ZR-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-95 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.84E+08 ZR-97 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 3.44E+06 MO-93 1.32E+08 1.32E+08 1.32E+08 1.32E+08 1.32E+08 1.32E+08 1.32E+08 5.39E+09 MO-99 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 4.63E+06 TC-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-99m 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 2.11E+05 TC-101 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.26E+04 RU-103 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.26E+08 RU-105 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 7.21E+05 RU-106 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 5.07E+08 RH-105 7.43E+05 7.43E+05 7.43E+05 7.43E+05 7.43E+05 7.43E+05 7.43E+05 8.67E+05 PD-107 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PD-109 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.71E+04 AG-110m 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 4.01E+09 AG-111 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.20E+06 CD-113m 6.87E+06 6.87E+06 6.87E+06 6.87E+06 6.87E+06 6.87E+06 6.87E+06 7.76E+06 CD-115m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-123 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.38E+09 SN-125 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.86E+06 SN-126 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.80E+10 SB-124 5.98E+08 5.98E+08 5.98E+08 5.98E+08 5.98E+08 5.98E+08 5.98E+08 6.90E+08 SB-125 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.71E+09 SB-126 8.44E+07 8.44E+07 8.44E+07 8.44E+07 8.44E+07 8.44E+07 8.44E+07 9.48E+07 SB-127 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.94E+07 TE-125m 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 2.13E+06 TE-127m 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 1.08E+05 TE-127 2.98E+03 2.98E+03 2.98E+03 2.98E+03 2.98E+03 2.98E+03 2.98E+03 3.28E+03 TE-129m 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 2.31E+07 TE-129 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 3.10E+04 TE-133m 4.41E+05 4.41E+05 4.41E+05 4.41E+05 4.41E+05 4.41E+05 4.41E+05 5.00E+05 II.4-116 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-28 (Page 3 of 4)
All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.66E+04 I-129 2.61E+09 2.61E+09 2.61E+09 2.61E+09 2.61E+09 2.61E+09 2.61E+09 4.35E+09 I-130 5.51E+06 5.51E+06 5.51E+06 5.51E+06 5.51E+06 5.51E+06 5.51E+06 6.69E+06 I-131 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 2.09E+07 TE-131m 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 9.46E+06 TE-131 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 3.45E+07 I-132 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.46E+06 TE-132 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.98E+06 I-133 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.98E+06 CS-134m 5.73E+04 5.73E+04 5.73E+04 5.73E+04 5.73E+04 5.73E+04 5.73E+04 6.74E+04 CS-134 6.91E+09 6.91E+09 6.91E+09 6.91E+09 6.91E+09 6.91E+09 6.91E+09 8.06E+09 I-134 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 5.30E+05 I-135 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.95E+06 CS-135 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-136 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.71E+08 CS-137 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 2.05E+10 CS-138 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 4.10E+05 CS-139 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.59E+04 BA-139 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.19E+05 BA-140 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.35E+07 LA-140 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 2.18E+07 BA-141 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.75E+04 LA-141 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.51E+04 CE-141 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.54E+07 BA-142 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 5.11E+04 LA-142 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 9.11E+05 CE-143 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.63E+06 PR-143 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-144 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 8.04E+07 PR-144 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 2.11E+03 ND-147 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 1.01E+07 PM-147 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-148m 4.45E+08 4.45E+08 4.45E+08 4.45E+08 4.45E+08 4.45E+08 4.45E+08 2.58E+09 PM-148 1.89E+07 1.89E+07 1.89E+07 1.89E+07 1.89E+07 1.89E+07 1.89E+07 2.18E+07 PM-149 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.90E+04 PM-151 1.99E+06 1.99E+06 1.99E+06 1.99E+06 1.99E+06 1.99E+06 1.99E+06 2.08E+06 SM-151 2.49E+08 2.49E+08 2.49E+08 2.49E+08 2.49E+08 2.49E+08 2.49E+08 1.09E+09 II.4-117 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-28 (Page 4 of 4)
All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.46E+05 EU-152 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.54E+10 EU-154 1.74E+10 1.74E+10 1.74E+10 1.74E+10 1.74E+10 1.74E+10 1.74E+10 2.00E+10 EU-155 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.90E+08 EU-156 8.82E+07 8.82E+07 8.82E+07 8.82E+07 8.82E+07 8.82E+07 8.82E+07 1.01E+08 TB-160 4.75E+08 4.75E+08 4.75E+08 4.75E+08 4.75E+08 4.75E+08 4.75E+08 5.53E+08 HO-166m 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.75E+10 W-181 1.94E+05 1.94E+05 1.94E+05 1.94E+05 1.94E+05 1.94E+05 1.94E+05 2.59E+05 W-185 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-187 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.73E+06 NP-239 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.98E+06 U-232 1.31E+07 1.31E+07 1.31E+07 1.31E+07 1.31E+07 1.31E+07 1.31E+07 1.36E+08 U-233 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.62E+10 U-234 3.67E+06 3.67E+06 3.67E+06 3.67E+06 3.67E+06 3.67E+06 3.67E+06 9.22E+08 U-235 1.86E+10 1.86E+10 1.86E+10 1.86E+10 1.86E+10 1.86E+10 1.86E+10 2.32E+10 U-236 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.04E+08 U-237 5.16E+06 5.16E+06 5.16E+06 5.16E+06 5.16E+06 5.16E+06 5.16E+06 6.71E+06 U-238 6.38E+08 6.38E+08 6.38E+08 6.38E+08 6.38E+08 6.38E+08 6.38E+08 8.70E+08 NP-237 8.12E+09 8.12E+09 8.12E+09 8.12E+09 8.12E+09 8.12E+09 8.12E+09 9.28E+09 NP-238 4.53E+06 4.53E+06 4.53E+06 4.53E+06 4.53E+06 4.53E+06 4.53E+06 5.18E+06 PU-238 6.71E+06 6.71E+06 6.71E+06 6.71E+06 6.71E+06 6.71E+06 6.71E+06 9.30E+07 PU-239 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.46E+07 PU-240 7.53E+06 7.53E+06 7.53E+06 7.53E+06 7.53E+06 7.53E+06 7.53E+06 1.04E+08 PU-241 1.41E+07 1.41E+07 1.41E+07 1.41E+07 1.41E+07 1.41E+07 1.41E+07 2.09E+07 PU-242 6.38E+06 6.38E+06 6.38E+06 6.38E+06 6.38E+06 6.38E+06 6.38E+06 9.28E+07 PU-244 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.58E+09 AM-241 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.47E+09 AM-242m 1.41E+08 1.41E+08 1.41E+08 1.41E+08 1.41E+08 1.41E+08 1.41E+08 9.76E+08 AM-243 7.53E+09 7.53E+09 7.53E+09 7.53E+09 7.53E+09 7.53E+09 7.53E+09 8.69E+09 CM-242 6.86E+05 6.86E+05 6.86E+05 6.86E+05 6.86E+05 6.86E+05 6.86E+05 2.87E+06 CM-243 9.47E+09 9.47E+09 9.47E+09 9.47E+09 9.47E+09 9.47E+09 9.47E+09 1.19E+10 CM-244 1.00E+07 1.00E+07 1.00E+07 1.00E+07 1.00E+07 1.00E+07 1.00E+07 6.21E+07 CM-245 5.50E+09 5.50E+09 5.50E+09 5.50E+09 5.50E+09 5.50E+09 5.50E+09 6.95E+09 CM-246 5.79E+06 5.79E+06 5.79E+06 5.79E+06 5.79E+06 5.79E+06 5.79E+06 8.68E+07 CM-247 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.51E+10 CM-248 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.95E+10 CF-252 4.86E+10 4.86E+10 4.86E+10 4.86E+10 4.86E+10 4.86E+10 4.86E+10 5.30E+10 II.4-118 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-29 (Page 1 of 4)
Infant Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 0.00E+00 C-14 2.65E+04 5.31E+03 5.31E+03 5.31E+03 5.31E+03 5.31E+03 5.31E+03 0.00E+00 NA-22 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 0.00E+00 NA-24 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 0.00E+00 P-32 2.03E+06 1.12E+05 7.74E+04 0.00E+00 0.00E+00 0.00E+00 1.61E+04 0.00E+00 CA-41 1.05E+05 0.00E+00 1.14E+04 0.00E+00 0.00E+00 9.72E+07 4.14E+02 0.00E+00 SC-46 5.25E+05 7.57E+05 2.37E+05 0.00E+00 4.98E+05 0.00E+00 3.07E+04 0.00E+00 CR-51 0.00E+00 0.00E+00 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 0.00E+00 MN-54 0.00E+00 2.53E+04 4.98E+03 0.00E+00 4.98E+03 1.00E+06 7.06E+03 0.00E+00 FE-55 1.97E+04 1.18E+04 3.33E+03 0.00E+00 0.00E+00 8.69E+04 1.10E+03 0.00E+00 MN-56 0.00E+00 1.54E+00 2.21E-01 0.00E+00 1.10E+00 1.25E+04 7.17E+04 0.00E+00 CO-57 0.00E+00 6.51E+02 6.41E+02 0.00E+00 0.00E+00 3.79E+05 4.86E+03 0.00E+00 CO-58 0.00E+00 1.22E+03 1.82E+03 0.00E+00 0.00E+00 7.77E+05 1.11E+04 0.00E+00 FE-59 1.36E+04 2.35E+04 9.48E+03 0.00E+00 0.00E+00 1.02E+06 2.48E+04 0.00E+00 CO-60 0.00E+00 8.02E+03 1.18E+04 0.00E+00 0.00E+00 4.51E+06 3.19E+04 0.00E+00 NI-59 2.53E+04 7.62E+03 4.34E+03 0.00E+00 0.00E+00 7.67E+04 8.88E+02 0.00E+00 NI-63 3.39E+05 2.04E+04 1.16E+04 0.00E+00 0.00E+00 2.09E+05 2.42E+03 0.00E+00 CU-64 0.00E+00 1.88E+00 7.74E-01 0.00E+00 3.98E+00 9.30E+03 1.50E+04 0.00E+00 NI-65 2.39E+00 2.84E-01 1.23E-01 0.00E+00 0.00E+00 8.12E+03 5.01E+04 0.00E+00 ZN-65 1.93E+04 6.26E+04 3.11E+04 0.00E+00 3.25E+04 6.47E+05 5.14E+04 0.00E+00 ZN-69m 1.26E+01 2.58E+01 2.34E+00 0.00E+00 1.04E+01 2.67E+04 4.09E+04 0.00E+00 ZN-69 5.39E-02 9.67E-02 7.18E-03 0.00E+00 4.02E-02 1.47E+03 1.32E+04 0.00E+00 SE-79 0.00E+00 3.15E+03 5.88E+02 0.00E+00 3.46E+03 4.19E+05 4.84E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 1.33E+04 0.00E+00 0.00E+00 0.00E+00 1.40E-15 0.00E+00 BR-83 0.00E+00 0.00E+00 3.81E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 4.00E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 2.04E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.90E+05 8.82E+04 0.00E+00 0.00E+00 0.00E+00 3.04E+03 0.00E+00 RB-87 0.00E+00 1.24E+05 4.93E+04 0.00E+00 0.00E+00 0.00E+00 8.37E+02 0.00E+00 RB-88 0.00E+00 5.57E+02 2.87E+02 0.00E+00 0.00E+00 0.00E+00 3.39E+02 0.00E+00 RB-89 0.00E+00 3.21E+02 2.06E+02 0.00E+00 0.00E+00 0.00E+00 6.82E+01 0.00E+00 SR-89 3.98E+05 0.00E+00 1.14E+04 0.00E+00 0.00E+00 2.03E+06 6.40E+04 0.00E+00 SR-90 4.09E+07 0.00E+00 2.59E+06 0.00E+00 0.00E+00 1.12E+07 1.31E+05 0.00E+00 Y-90 3.29E+03 0.00E+00 8.82E+01 0.00E+00 0.00E+00 2.69E+05 1.04E+05 0.00E+00 SR-91 9.56E+01 0.00E+00 3.46E+00 0.00E+00 0.00E+00 5.26E+04 7.34E+04 0.00E+00 Y-91m 4.07E-01 0.00E+00 1.39E-02 0.00E+00 0.00E+00 2.79E+03 2.35E+03 0.00E+00 Y-91 5.88E+05 0.00E+00 1.57E+04 0.00E+00 0.00E+00 2.45E+06 7.03E+04 0.00E+00 II.4-119 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-29 (Page 2 of 4)
Infant Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 1.05E+01 0.00E+00 3.91E-01 0.00E+00 0.00E+00 2.38E+04 1.40E+05 0.00E+00 Y-92 1.64E+01 0.00E+00 4.61E-01 0.00E+00 0.00E+00 2.45E+04 1.27E+05 0.00E+00 Y-93 1.50E+02 0.00E+00 4.07E+00 0.00E+00 0.00E+00 7.64E+04 1.67E+05 0.00E+00 NB-93m 1.93E+05 5.03E+04 1.61E+04 0.00E+00 5.15E+04 2.93E+05 3.46E+03 0.00E+00 NB-95 1.57E+04 6.43E+03 3.78E+03 0.00E+00 4.72E+03 4.79E+05 1.27E+04 0.00E+00 NB-97 3.42E-01 7.29E-02 2.63E-02 0.00E+00 5.70E-02 3.32E+03 2.69E+04 0.00E+00 ZR-93 3.14E+05 1.33E+05 8.65E+04 0.00E+00 4.47E+05 1.92E+06 2.07E+04 0.00E+00 ZR-95 1.15E+05 2.79E+04 2.03E+04 0.00E+00 3.11E+04 1.75E+06 2.17E+04 0.00E+00 ZR-97 1.50E+02 2.56E+01 1.17E+01 0.00E+00 2.59E+01 1.10E+05 1.40E+05 0.00E+00 MO-93 0.00E+00 9.04E+03 3.11E+02 0.00E+00 2.16E+03 4.76E+05 5.26E+03 0.00E+00 MO-99 0.00E+00 1.65E+02 3.23E+01 0.00E+00 2.65E+02 1.35E+05 4.87E+04 0.00E+00 TC-99 2.93E+02 3.75E+02 1.24E+02 0.00E+00 3.49E+03 9.48E+05 1.09E+04 0.00E+00 TC-99m 1.40E-03 2.88E-03 3.72E-02 0.00E+00 3.11E-02 8.11E+02 2.03E+03 0.00E+00 TC-101 6.51E-05 8.23E-05 8.12E-04 0.00E+00 9.79E-04 5.84E+02 8.44E+02 0.00E+00 RU-103 2.02E+03 0.00E+00 6.79E+02 0.00E+00 4.24E+03 5.52E+05 1.61E+04 0.00E+00 RU-105 1.22E+00 0.00E+00 4.10E-01 0.00E+00 8.99E-01 1.57E+04 4.84E+04 0.00E+00 RU-106 8.68E+04 0.00E+00 1.09E+04 0.00E+00 1.07E+05 1.16E+07 1.64E+05 0.00E+00 RH-105 1.16E+01 7.57E+00 5.08E+00 0.00E+00 2.10E+01 2.91E+04 1.92E+04 0.00E+00 PD-107 0.00E+00 6.89E+01 5.75E+01 0.00E+00 3.85E+03 8.88E+04 1.03E+03 0.00E+00 PD-109 0.00E+00 5.49E+00 1.47E+00 0.00E+00 1.79E+01 2.35E+04 3.99E+04 0.00E+00 AG-110m 9.98E+03 7.22E+03 5.00E+03 0.00E+00 1.09E+04 3.67E+06 3.30E+04 0.00E+00 AG-111 5.25E+02 2.03E+02 1.09E+02 0.00E+00 4.27E+02 2.88E+05 4.23E+04 0.00E+00 CD-113m 0.00E+00 9.34E+05 3.70E+04 0.00E+00 8.12E+05 1.96E+06 2.31E+04 0.00E+00 CD-115m 0.00E+00 2.42E+05 8.67E+03 0.00E+00 1.32E+05 2.06E+06 7.03E+04 0.00E+00 SN-123 2.93E+05 5.89E+03 1.02E+04 5.98E+03 0.00E+00 3.11E+06 5.71E+04 0.00E+00 SN-125 1.41E+04 3.51E+02 8.40E+02 3.46E+02 0.00E+00 9.00E+05 1.02E+05 0.00E+00 SN-126 1.16E+06 2.02E+04 4.93E+04 5.38E+03 0.00E+00 6.90E+06 2.31E+04 0.00E+00 SB-124 3.79E+04 5.56E+02 1.20E+04 1.01E+02 0.00E+00 2.65E+06 5.91E+04 0.00E+00 SB-125 5.45E+04 4.77E+02 1.09E+04 6.23E+01 0.00E+00 1.64E+06 1.47E+04 0.00E+00 SB-126 4.31E+03 8.41E+01 1.55E+02 3.29E+01 0.00E+00 9.63E+05 7.46E+04 0.00E+00 SB-127 3.95E+02 7.06E+00 1.23E+02 5.04E+00 0.00E+00 2.16E+05 5.29E+04 0.00E+00 TE-125m 4.76E+03 1.99E+03 6.58E+02 1.62E+03 0.00E+00 4.47E+05 1.29E+04 0.00E+00 TE-127m 1.67E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.31E+06 2.73E+04 0.00E+00 TE-127 2.23E+00 9.53E-01 4.89E-01 1.85E+00 4.86E+00 1.04E+04 2.44E+04 0.00E+00 TE-129m 1.41E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 0.00E+00 TE-129 7.88E-02 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.00E+03 2.63E+04 0.00E+00 TE-133m 8.58E-02 5.03E-02 3.84E-02 7.73E-02 2.41E-01 5.49E+03 2.23E+04 0.00E+00 II.4-120 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-29 (Page 3 of 4)
Infant Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 4.45E-02 2.86E-02 2.35E-02 4.07E-02 1.34E-01 4.10E+03 3.54E+03 0.00E+00 I-129 3.02E+04 2.23E+04 1.62E+04 1.46E+07 2.63E+04 0.00E+00 2.97E+02 0.00E+00 I-130 6.36E+03 1.39E+04 5.57E+03 1.60E+06 1.53E+04 0.00E+00 1.99E+03 0.00E+00 I-131 3.79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 0.00E+00 1.06E+03 0.00E+00 TE-131m 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+05 1.19E+05 0.00E+00 TE-131 1.74E-02 8.22E-03 5.00E-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 0.00E+00 I-132 1.69E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 0.00E+00 1.90E+03 0.00E+00 TE-132 3.72E+02 2.37E+02 1.76E+02 2.79E+02 1.04E+03 3.40E+05 4.41E+04 0.00E+00 I-133 1.32E+04 1.92E+04 5.60E+03 3.56E+06 2.24E+04 0.00E+00 2.16E+03 0.00E+00 CS-134m 1.85E+02 2.94E+02 1.55E+02 0.00E+00 1.19E+02 2.80E+01 1.62E+02 0.00E+00 CS-134 3.96E+05 7.03E+05 7.45E+04 0.00E+00 1.90E+05 7.97E+04 1.33E+03 0.00E+00 I-134 9.21E+02 1.88E+03 6.65E+02 4.45E+04 2.09E+03 0.00E+00 1.29E+03 0.00E+00 I-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 0.00E+00 1.83E+03 0.00E+00 CS-135 1.40E+05 1.21E+05 6.62E+03 0.00E+00 3.61E+04 1.41E+04 3.05E+02 0.00E+00 CS-136 4.83E+04 1.35E+05 5.29E+04 0.00E+00 5.64E+04 1.18E+04 1.43E+03 0.00E+00 CS-137 5.49E+05 6.12E+05 4.55E+04 0.00E+00 1.72E+05 7.13E+04 1.33E+03 0.00E+00 CS-138 5.05E+02 7.81E+02 3.98E+02 0.00E+00 4.10E+02 6.54E+01 8.76E+02 0.00E+00 CS-139 3.25E+02 4.24E+02 1.71E+02 0.00E+00 2.31E+02 3.54E+01 1.86E+01 0.00E+00 BA-139 1.48E+00 9.84E-04 4.30E-02 0.00E+00 5.92E-04 5.95E+03 5.10E+04 0.00E+00 BA-140 5.60E+04 5.60E+01 2.90E+03 0.00E+00 1.34E+01 1.60E+06 3.84E+04 0.00E+00 LA-140 5.05E+02 2.00E+02 5.15E+01 0.00E+00 0.00E+00 1.68E+05 8.48E+04 0.00E+00 BA-141 1.57E-01 1.08E-04 4.97E-03 0.00E+00 6.50E-05 2.97E+03 4.75E+03 0.00E+00 LA-141 6.79E+00 1.96E+00 3.43E-01 0.00E+00 0.00E+00 1.71E+04 8.34E+04 0.00E+00 CE-141 2.77E+04 1.67E+04 1.99E+03 0.00E+00 5.25E+03 5.17E+05 2.16E+04 0.00E+00 BA-142 3.98E-02 3.30E-05 1.96E-03 0.00E+00 1.90E-05 1.55E+03 6.93E+02 0.00E+00 LA-142 1.03E+00 3.77E-01 9.04E-02 0.00E+00 0.00E+00 8.22E+03 5.95E+04 0.00E+00 CE-143 2.93E+02 1.93E+02 2.21E+01 0.00E+00 5.64E+01 1.16E+05 4.97E+04 0.00E+00 PR-143 1.40E+04 5.24E+03 6.99E+02 0.00E+00 1.97E+03 4.33E+05 3.72E+04 0.00E+00 CE-144 3.19E+06 1.21E+06 1.76E+05 0.00E+00 5.38E+05 9.84E+06 1.48E+05 0.00E+00 PR-144 4.79E-02 1.85E-02 2.41E-03 0.00E+00 6.72E-03 1.61E+03 4.28E+03 0.00E+00 ND-147 7.94E+03 8.13E+03 5.00E+02 0.00E+00 3.15E+03 3.22E+05 3.12E+04 0.00E+00 PM-147 5.47E+05 4.30E+04 2.18E+04 0.00E+00 6.90E+04 6.37E+05 8.05E+03 0.00E+00 PM-148m 7.00E+04 1.74E+04 1.39E+04 0.00E+00 2.03E+04 1.71E+06 4.72E+04 0.00E+00 PM-148 4.68E+03 6.75E+01 3.42E+02 0.00E+00 8.06E+02 4.48E+05 8.46E+04 0.00E+00 PM-149 4.34E+02 5.71E+01 2.49E+01 0.00E+00 6.94E+01 9.10E+04 4.21E+04 0.00E+00 PM-151 1.05E+02 1.54E+01 7.77E+00 0.00E+00 1.82E+01 4.55E+04 3.61E+04 0.00E+00 SM-151 4.73E+05 9.03E+04 2.28E+04 0.00E+00 7.34E+04 4.17E+05 4.84E+03 0.00E+00 II.4-121 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-29 (Page 4 of 4)
Infant Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 2.14E+02 1.65E+02 1.27E+01 0.00E+00 3.46E+01 5.18E+04 2.70E+04 0.00E+00 EU-152 1.10E+06 2.48E+05 2.41E+05 0.00E+00 8.32E+05 2.07E+06 1.38E+04 0.00E+00 EU-154 4.14E+06 4.84E+05 3.43E+05 0.00E+00 1.60E+06 4.27E+06 3.98E+04 0.00E+00 EU-155 8.36E+05 8.01E+04 4.84E+04 0.00E+00 2.21E+05 7.28E+05 7.27E+04 0.00E+00 EU-156 2.18E+04 1.34E+04 2.16E+03 0.00E+00 6.27E+03 8.57E+05 5.80E+04 0.00E+00 TB-160 1.57E+05 0.00E+00 1.96E+04 0.00E+00 4.48E+04 1.55E+06 3.00E+04 0.00E+00 HO-166m 2.03E+05 4.30E+05 3.51E+05 0.00E+00 5.91E+05 2.87E+06 2.31E+04 0.00E+00 W-181 6.80E+01 2.04E+01 2.34E+00 0.00E+00 0.00E+00 1.86E+04 3.68E+02 0.00E+00 W-185 2.20E+03 6.76E+02 7.81E+01 0.00E+00 0.00E+00 6.27E+05 1.57E+04 0.00E+00 W-187 1.30E+01 9.02E+00 3.12E+00 0.00E+00 0.00E+00 3.96E+04 3.56E+04 0.00E+00 NP-239 3.71E+02 3.32E+01 1.88E+01 0.00E+00 6.62E+01 5.95E+04 2.49E+04 0.00E+00 U-232 3.60E+08 0.00E+00 2.98E+07 0.00E+00 3.36E+07 2.09E+09 6.10E+04 0.00E+00 U-233 7.62E+07 0.00E+00 5.36E+06 0.00E+00 1.53E+07 4.98E+08 5.64E+04 0.00E+00 U-234 7.31E+07 0.00E+00 5.25E+06 0.00E+00 1.50E+07 4.89E+08 5.53E+04 0.00E+00 U-235 7.01E+07 0.00E+00 4.93E+06 0.00E+00 1.41E+07 4.59E+08 7.03E+04 0.00E+00 U-236 7.01E+07 0.00E+00 5.04E+06 0.00E+00 1.44E+07 4.69E+08 5.19E+04 0.00E+00 U-237 4.55E+02 0.00E+00 1.21E+02 0.00E+00 1.13E+03 1.28E+05 1.83E+04 0.00E+00 U-238 6.71E+07 0.00E+00 4.61E+06 0.00E+00 1.32E+07 4.28E+08 4.96E+04 0.00E+00 NP-237 4.03E+09 2.39E+09 1.76E+08 0.00E+00 1.08E+09 4.89E+08 7.14E+04 0.00E+00 NP-238 3.74E+03 8.47E+02 5.82E+01 0.00E+00 2.06E+02 1.29E+05 3.61E+04 0.00E+00 PU-238 3.77E+09 2.35E+09 1.78E+08 0.00E+00 6.50E+08 1.26E+09 6.57E+04 0.00E+00 PU-239 4.10E+09 2.46E+09 1.88E+08 0.00E+00 6.93E+08 1.19E+09 5.99E+04 0.00E+00 PU-240 4.10E+09 2.45E+09 1.88E+08 0.00E+00 6.92E+08 1.19E+09 6.10E+04 0.00E+00 PU-241 1.18E+08 2.59E+07 4.35E+06 0.00E+00 1.61E+07 1.07E+06 1.26E+03 0.00E+00 PU-242 3.81E+09 2.37E+09 1.81E+08 0.00E+00 6.68E+08 1.14E+09 5.88E+04 0.00E+00 PU-244 4.44E+09 2.72E+09 2.07E+08 0.00E+00 7.64E+08 1.31E+09 8.76E+04 0.00E+00 AM-241 4.41E+09 2.73E+09 1.83E+08 0.00E+00 1.11E+09 5.68E+08 6.69E+04 0.00E+00 AM-242m 4.55E+09 2.60E+09 1.89E+08 0.00E+00 1.12E+09 2.30E+08 8.41E+04 0.00E+00 AM-243 4.34E+09 2.63E+09 1.78E+08 0.00E+00 1.08E+09 5.39E+08 7.84E+04 0.00E+00 CM-242 1.79E+08 1.21E+08 7.98E+06 0.00E+00 2.37E+07 4.16E+08 7.14E+04 0.00E+00 CM-243 3.46E+09 2.13E+09 1.48E+08 0.00E+00 5.47E+08 5.94E+08 7.03E+04 0.00E+00 CM-244 2.90E+09 1.78E+09 1.24E+08 0.00E+00 4.49E+08 5.71E+08 6.80E+04 0.00E+00 CM-245 4.51E+09 2.74E+09 1.90E+08 0.00E+00 7.32E+08 5.49E+08 6.34E+04 0.00E+00 CM-246 4.48E+09 2.74E+09 1.90E+08 0.00E+00 7.32E+08 5.59E+08 6.23E+04 0.00E+00 CM-247 4.35E+09 2.70E+09 1.86E+08 0.00E+00 7.21E+08 5.49E+08 8.19E+04 0.00E+00 CM-248 3.61E+10 2.23E+10 1.54E+09 0.00E+00 5.94E+09 4.52E+09 1.32E+06 0.00E+00 CF-252 3.32E+09 0.00E+00 1.41E+08 0.00E+00 0.00E+00 1.92E+09 2.59E+05 0.00E+00 II.4-122 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-30 (Page 1 of 4)
Child Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 0.00E+00 C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 0.00E+00 NA-22 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 0.00E+00 NA-24 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 0.00E+00 P-32 2.61E+06 1.14E+05 9.88E+04 0.00E+00 0.00E+00 0.00E+00 4.22E+04 0.00E+00 CA-41 2.61E+05 0.00E+00 2.85E+04 0.00E+00 0.00E+00 2.67E+08 1.09E+03 0.00E+00 SC-46 7.29E+05 9.99E+05 3.85E+05 0.00E+00 8.84E+05 0.00E+00 9.07E+04 0.00E+00 CR-51 0.00E+00 0.00E+00 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 0.00E+00 MN-54 0.00E+00 4.29E+04 9.51E+03 0.00E+00 1.00E+04 1.58E+06 2.29E+04 0.00E+00 FE-55 4.74E+04 2.52E+04 7.77E+03 0.00E+00 0.00E+00 1.11E+05 2.87E+03 0.00E+00 MN-56 0.00E+00 1.66E+00 3.12E-01 0.00E+00 1.67E+00 1.31E+04 1.23E+05 0.00E+00 CO-57 0.00E+00 9.03E+02 1.07E+03 0.00E+00 0.00E+00 5.07E+05 1.32E+04 0.00E+00 CO-58 0.00E+00 1.77E+03 3.16E+03 0.00E+00 0.00E+00 1.11E+06 3.44E+04 0.00E+00 FE-59 2.07E+04 3.35E+04 1.67E+04 0.00E+00 0.00E+00 1.27E+06 7.07E+04 0.00E+00 CO-60 0.00E+00 1.31E+04 2.26E+04 0.00E+00 0.00E+00 7.07E+06 9.62E+04 0.00E+00 NI-59 6.14E+04 1.73E+04 1.05E+04 0.00E+00 0.00E+00 1.01E+05 2.33E+03 0.00E+00 NI-63 8.21E+05 4.63E+04 2.80E+04 0.00E+00 0.00E+00 2.75E+05 6.33E+03 0.00E+00 CU-64 0.00E+00 1.99E+00 1.07E+00 0.00E+00 6.03E+00 9.58E+03 3.67E+04 0.00E+00 NI-65 2.99E+00 2.96E-01 1.64E-01 0.00E+00 0.00E+00 8.18E+03 8.40E+04 0.00E+00 ZN-65 4.26E+04 1.13E+05 7.03E+04 0.00E+00 7.14E+04 9.95E+05 1.63E+04 0.00E+00 ZN-69m 1.58E+01 2.69E+01 3.18E+00 0.00E+00 1.56E+01 2.72E+04 1.00E+05 0.00E+00 ZN-69 6.70E-02 9.66E-02 8.92E-03 0.00E+00 5.85E-02 1.42E+03 1.02E+04 0.00E+00 SE-79 0.00E+00 4.55E+03 9.62E+02 0.00E+00 6.33E+03 5.51E+05 1.27E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 2.09E+04 0.00E+00 0.00E+00 0.00E+00 3.70E-15 0.00E+00 BR-83 0.00E+00 0.00E+00 4.74E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 5.48E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 2.53E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.98E+05 1.14E+05 0.00E+00 0.00E+00 0.00E+00 7.99E+03 0.00E+00 RB-87 0.00E+00 1.17E+05 5.07E+04 0.00E+00 0.00E+00 0.00E+00 1.10E+03 0.00E+00 RB-88 0.00E+00 5.62E+02 3.66E+02 0.00E+00 0.00E+00 0.00E+00 1.72E+01 0.00E+00 RB-89 0.00E+00 3.45E+02 2.90E+02 0.00E+00 0.00E+00 0.00E+00 1.89E+00 0.00E+00 SR-89 5.99E+05 0.00E+00 1.72E+04 0.00E+00 0.00E+00 2.16E+06 1.67E+05 0.00E+00 SR-90 1.01E+08 0.00E+00 6.44E+06 0.00E+00 0.00E+00 1.48E+07 3.43E+05 0.00E+00 Y-90 4.11E+03 0.00E+00 1.11E+02 0.00E+00 0.00E+00 2.62E+05 2.68E+05 0.00E+00 SR-91 1.21E+02 0.00E+00 4.59E+00 0.00E+00 0.00E+00 5.33E+04 1.74E+05 0.00E+00 Y-91m 5.07E-01 0.00E+00 1.84E-02 0.00E+00 0.00E+00 2.81E+03 1.72E+03 0.00E+00 Y-91 9.14E+05 0.00E+00 2.44E+04 0.00E+00 0.00E+00 2.63E+06 1.84E+05 0.00E+00 II.4-123 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-30 (Page 2 of 4)
Child Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 1.31E+01 0.00E+00 5.25E-01 0.00E+00 0.00E+00 2.40E+04 2.42E+05 0.00E+00 Y-92 2.04E+01 0.00E+00 5.81E-01 0.00E+00 0.00E+00 2.39E+04 2.39E+05 0.00E+00 Y-93 1.87E+02 0.00E+00 5.11E+00 0.00E+00 0.00E+00 7.44E+04 3.89E+05 0.00E+00 NB-93m 4.70E+05 1.17E+05 3.85E+04 0.00E+00 1.26E+05 3.85E+05 9.07E+03 0.00E+00 NB-95 2.35E+04 9.18E+03 6.55E+03 0.00E+00 8.62E+03 6.14E+05 3.70E+04 0.00E+00 NB-97 4.29E-01 7.70E-02 3.60E-02 0.00E+00 8.55E-02 3.42E+03 2.78E+04 0.00E+00 ZR-93 7.66E+05 2.89E+05 2.05E+05 0.00E+00 1.11E+06 2.63E+06 5.44E+04 0.00E+00 ZR-95 1.90E+05 4.18E+04 3.70E+04 0.00E+00 5.96E+04 2.23E+06 6.11E+04 0.00E+00 ZR-97 1.88E+02 2.72E+01 1.60E+01 0.00E+00 3.89E+01 1.13E+05 3.51E+05 0.00E+00 MO-93 0.00E+00 1.39E+04 5.00E+02 0.00E+00 3.92E+03 6.29E+05 1.40E+04 0.00E+00 MO-99 0.00E+00 1.72E+02 4.26E+01 0.00E+00 3.92E+02 1.35E+05 1.27E+05 0.00E+00 TC-99 4.96E+02 5.51E+02 1.98E+02 0.00E+00 6.48E+03 1.25E+06 2.87E+04 0.00E+00 TC-99m 1.78E-03 3.48E-03 5.77E-02 0.00E+00 5.07E-02 9.51E+02 4.81E+03 0.00E+00 TC-101 8.10E-05 8.51E-05 1.08E-03 0.00E+00 1.45E-03 5.85E+02 1.63E+01 0.00E+00 RU-103 2.79E+03 0.00E+00 1.07E+03 0.00E+00 7.03E+03 6.62E+05 4.48E+04 0.00E+00 RU-105 1.53E+00 0.00E+00 5.55E-01 0.00E+00 1.34E+00 1.59E+04 9.95E+04 0.00E+00 RU-106 1.36E+05 0.00E+00 1.69E+04 0.00E+00 1.84E+05 1.43E+07 4.29E+05 0.00E+00 RH-105 1.45E+01 7.77E+00 6.62E+00 0.00E+00 3.10E+01 2.89E+04 4.92E+04 0.00E+00 PD-107 0.00E+00 9.81E+02 9.29E+01 0.00E+00 7.29E+03 1.17E+05 2.69E+03 0.00E+00 PD-109 0.00E+00 5.48E+00 1.83E+00 0.00E+00 2.61E+01 2.28E+04 9.58E+04 0.00E+00 AG-110m 1.69E+04 1.14E+04 9.14E+03 0.00E+00 2.12E+04 5.48E+06 1.00E+05 0.00E+00 AG-111 6.70E+02 2.10E+02 1.39E+02 0.00E+00 6.33E+02 2.86E+05 1.10E+05 0.00E+00 CD-113m 0.00E+00 1.82E+06 7.84E+04 0.00E+00 1.90E+06 2.57E+06 6.03E+04 0.00E+00 CD-115m 0.00E+00 2.92E+05 1.25E+04 0.00E+00 2.19E+05 2.17E+06 1.84E+05 0.00E+00 SN-123 4.77E+05 7.92E+03 1.55E+04 8.40E+03 0.00E+00 3.55E+06 1.50E+05 0.00E+00 SN-125 1.83E+04 3.68E+02 1.09E+03 3.81E+02 0.00E+00 8.99E+05 2.65E+05 0.00E+00 SN-126 2.31E+06 3.85E+04 8.73E+04 1.05E+04 0.00E+00 1.12E+07 6.03E+04 0.00E+00 SB-124 5.66E+06 7.40E+02 2.00E+04 1.26E+02 0.00E+00 3.24E+06 1.64E+05 0.00E+00 SB-125 9.84E+04 7.59E+02 1.99E+04 9.10E+01 0.00E+00 2.32E+06 4.03E+04 0.00E+00 SB-126 6.36E+03 9.69E+01 2.28E+03 3.70E+01 0.00E+00 1.06E+06 2.10E+05 0.00E+00 SB-127 5.03E+02 7.73E+00 1.74E+02 5.59E+00 0.00E+00 2.28E+05 1.41E+05 0.00E+00 TE-125m 6.73E+03 2.33E+03 9.14E+02 1.92E+03 0.00E+00 4.77E+05 3.38E+04 0.00E+00 TE-127m 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 0.00E+00 TE-127 2.77E+00 9.51E-01 6.11E-01 1.96E+00 7.07E+00 1.00E+04 5.62E+04 0.00E+00 TE-129m 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 0.00E+00 TE-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 0.00E+00 TE-133m 1.08E-01 5.59E-02 5.55E-02 8.58E-02 3.74E-01 5.92E+03 1.76E+04 0.00E+00 II.4-124 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-30 (Page 3 of 4)
Child Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 5.66E-02 3.26E-02 3.48E-02 4.59E-02 2.11E-01 4.55E+03 1.80E+03 0.00E+00 I-129 3.89E+04 2.37E+04 2.11E+04 1.58E+07 4.00E+04 0.00E+00 7.96E+02 0.00E+00 I-130 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 0.00E+00 5.11E+03 0.00E+00 I-131 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 0.00E+00 2.84E+03 0.00E+00 TE-131m 1.34E+02 5.92E+01 5.07E+01 9.77E+01 4.00E+02 2.06E+05 3.08E+05 0.00E+00 TE-131 2.17E-02 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 1.33E+03 0.00E+00 I-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25E+03 0.00E+00 3.20E+03 0.00E+00 TE-132 4.81E+02 2.72E+02 2.63E+02 3.18E+02 1.77E+03 3.77E+05 1.38E+05 0.00E+00 I-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 0.00E+00 5.48E+03 0.00E+00 CS-134m 2.34E+02 3.30E+02 2.26E+02 0.00E+00 1.83E+02 3.09E+01 2.93E+02 0.00E+00 CS-134 6.51E+05 1.01E+06 2.25E+05 0.00E+00 3.30E+05 1.21E+05 3.85E+03 0.00E+00 I-134 1.17E+03 2.16E+03 9.95E+02 5.07E+04 3.30E+03 0.00E+00 9.55E+02 0.00E+00 I-135 4.92E+03 8.73E+03 4.14E+03 7.92E+05 1.34E+04 0.00E+00 4.44E+03 0.00E+00 CS-135 2.31E+05 1.53E+05 1.65E+04 0.00E+00 5.66E+04 1.93E+04 8.03E+02 0.00E+00 CS-136 6.51E+04 1.71E+05 1.16E+05 0.00E+00 9.55E+04 1.45E+04 4.18E+03 0.00E+00 CS-137 9.07E+05 8.25E+05 1.28E+05 0.00E+00 2.82E+05 1.04E+05 3.62E+03 0.00E+00 CS-138 6.33E+02 8.40E+02 5.55E+02 0.00E+00 6.22E+02 6.81E+01 2.70E+02 0.00E+00 CS-139 4.03E+02 4.26E+02 2.15E+02 0.00E+00 3.36E+02 3.46E+01 2.68E-02 0.00E+00 BA-139 1.84E+00 9.84E-04 5.37E-02 0.00E+00 8.62E-04 5.77E+03 5.77E+04 0.00E+00 BA-140 7.40E+04 6.48E+01 4.33E+03 0.00E+00 2.11E+01 1.74E+06 1.02E+05 0.00E+00 LA-140 6.44E+02 2.25E+02 7.55E+01 0.00E+00 0.00E+00 1.83E+05 2.26E+05 0.00E+00 BA-141 1.96E-01 1.09E-04 6.36E-03 0.00E+00 9.47E-05 2.92E+03 2.75E+02 0.00E+00 LA-141 8.47E+00 1.96E+00 4.26E-01 0.00E+00 0.00E+00 1.66E+04 1.62E+05 0.00E+00 CE-141 3.92E+04 1.95E+04 2.90E+03 0.00E+00 8.55E+03 5.44E+05 5.66E+04 0.00E+00 BA-142 5.00E-02 3.60E-05 2.79E-03 0.00E+00 2.91E-05 1.64E+03 2.74E+00 0.00E+00 LA-142 1.30E+00 4.11E-01 1.29E-01 0.00E+00 0.00E+00 8.70E+03 7.59E+04 0.00E+00 CE-143 3.66E+02 1.99E+02 2.88E+01 0.00E+00 8.36E+01 1.15E+05 1.27E+05 0.00E+00 PR-143 1.85E+04 5.55E+03 9.14E+02 0.00E+00 3.00E+03 4.33E+05 9.73E+04 0.00E+00 CE-144 6.77E+06 2.12E+06 3.62E+05 0.00E+00 1.17E+06 1.20E+07 3.89E+05 0.00E+00 PR-144 5.96E-02 1.85E-02 3.00E-03 0.00E+00 9.77E-03 1.57E+03 1.97E+02 0.00E+00 ND-147 1.08E+04 8.73E+03 6.81E+02 0.00E+00 4.81E+03 3.28E+05 8.21E+04 0.00E+00 PM-147 1.30E+06 9.32E+04 5.03E+04 0.00E+00 1.65E+05 8.14E+05 2.11E+04 0.00E+00 PM-148m 1.22E+05 2.42E+04 2.42E+04 0.00E+00 3.60E+04 2.12E+06 1.32E+05 0.00E+00 PM-148 5.96E+03 7.18E+02 4.63E+02 0.00E+00 1.22E+03 4.59E+05 2.22E+05 0.00E+00 PM-149 5.44E+02 5.77E+01 3.13E+01 0.00E+00 1.02E+02 8.88E+04 1.08E+05 0.00E+00 PM-151 1.32E+02 1.60E+01 1.04E+01 0.00E+00 2.72E+01 4.59E+04 9.55E+04 0.00E+00 SM-151 1.16E+06 1.76E+05 5.51E+04 0.00E+00 1.81E+05 5.48E+05 1.27E+04 0.00E+00 II.4-125 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-30 (Page 4 of 4)
Child Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 2.68E+02 1.67E+02 1.61E+01 0.00E+00 5.07E+01 5.07E+04 6.92E+04 0.00E+00 EU-152 2.75E+06 5.07E+05 5.96E+05 0.00E+00 2.12E+06 3.33E+06 4.22E+04 0.00E+00 EU-154 1.01E+07 9.21E+05 8.40E+05 0.00E+00 4.03E+06 6.14E+06 1.10E+05 0.00E+00 EU-155 2.07E+06 1.50E+05 1.18E+05 0.00E+00 5.59E+05 1.03E+06 1.99E+05 0.00E+00 EU-156 2.92E+04 1.57E+04 3.24E+03 0.00E+00 1.01E+04 9.40E+05 1.57E+05 0.00E+00 TB-160 2.88E+05 0.00E+00 3.58E+04 0.00E+00 8.58E+04 1.98E+06 8.44E+04 0.00E+00 HO-166m 4.96E+06 1.04E+06 8.77E+05 0.00E+00 1.48E+06 4.18E+06 6.03E+04 0.00E+00 W-181 9.84E+01 2.41E+01 3.33E+00 0.00E+00 0.00E+00 2.11E+04 9.66E+02 0.00E+00 W-185 3.07E+03 7.70E+02 1.08E+02 0.00E+00 0.00E+00 6.88E+05 4.11E+04 0.00E+00 W-187 1.63E+01 9.66E+00 4.33E+00 0.00E+00 0.00E+00 4.11E+04 9.10E+04 0.00E+00 NP-239 4.66E+02 3.35E+01 2.35E+01 0.00E+00 9.73E+01 5.81E+04 6.40E+04 0.00E+00 U-232 8.10E+08 0.00E+00 5.77E+07 0.00E+00 6.18E+07 2.75E+09 1.60E+05 0.00E+00 U-233 1.72E+08 0.00E+00 1.04E+07 0.00E+00 2.82E+07 6.55E+08 1.48E+05 0.00E+00 U-234 1.65E+08 0.00E+00 1.02E+07 0.00E+00 2.76E+07 6.44E+08 1.45E+05 0.00E+00 U-235 1.58E+08 0.00E+00 9.58E+06 0.00E+00 2.59E+07 6.03E+08 1.84E+05 0.00E+00 U-236 1.58E+08 0.00E+00 9.81E+06 0.00E+00 2.65E+07 6.18E+08 1.36E+05 0.00E+00 U-237 5.81E+02 0.00E+00 1.54E+02 0.00E+00 1.68E+03 1.26E+05 4.77E+04 0.00E+00 U-238 1.51E+08 0.00E+00 8.95E+06 0.00E+00 2.42E+07 5.66E+08 1.30E+05 0.00E+00 NP-237 1.01E+10 5.99E+09 4.40E+08 0.00E+00 2.74E+09 6.44E+08 1.87E+05 0.00E+00 NP-238 4.66E+03 8.51E+02 7.29E+01 0.00E+00 3.02E+02 1.25E+05 9.25E+04 0.00E+00 PU-238 9.44E+09 5.92E+09 4.48E+08 0.00E+00 1.65E+09 2.25E+09 1.72E+05 0.00E+00 PU-239 1.03E+10 6.22E+09 4.74E+08 0.00E+00 1.77E+09 2.12E+09 1.57E+05 0.00E+00 PU-240 1.03E+10 6.22E+09 4.70E+08 0.00E+00 1.76E+09 2.11E+09 1.60E+05 0.00E+00 PU-241 2.94E+08 6.48E+07 1.08E+07 0.00E+00 4.07E+07 1.87E+06 3.29E+03 0.00E+00 PU-242 9.58E+09 5.99E+09 4.55E+08 0.00E+00 1.70E+09 2.04E+09 1.54E+05 0.00E+00 PU-244 1.12E+10 6.85E+09 5.22E+08 0.00E+00 1.95E+09 2.33E+09 2.29E+05 0.00E+00 AM-241 1.10E+10 6.81E+09 4.59E+08 0.00E+00 2.82E+09 7.47E+08 1.75E+05 0.00E+00 AM-242m 1.14E+10 6.51E+09 4.70E+08 0.00E+00 2.85E+09 3.01E+08 2.21E+05 0.00E+00 AM-243 1.09E+10 6.59E+09 4.44E+08 0.00E+00 2.75E+09 7.10E+08 2.05E+05 0.00E+00 CM-242 3.51E+08 2.10E+08 1.55E+07 0.00E+00 4.96E+07 4.85E+08 1.87E+05 0.00E+00 CM-243 8.58E+09 5.25E+09 3.68E+08 0.00E+00 1.38E+09 7.77E+08 1.84E+05 0.00E+00 CM-244 7.18E+09 4.37E+09 3.07E+08 0.00E+00 1.13E+09 7.47E+08 1.78E+05 0.00E+00 CM-245 1.13E+10 6.81E+09 4.74E+08 0.00E+00 1.86E+09 7.22E+08 1.66E+05 0.00E+00 CM-246 1.12E+10 6.81E+09 4.74E+08 0.00E+00 1.86E+09 7.36E+08 1.63E+05 0.00E+00 CM-247 1.09E+10 6.73E+09 4.66E+08 0.00E+00 1.83E+09 7.22E+08 2.15E+05 0.00E+00 CM-248 9.07E+10 5.55E+10 3.85E+09 0.00E+00 1.51E+10 5.96E+09 3.46E+06 0.00E+00 CF-252 8.07E+09 0.00E+00 3.45E+08 0.00E+00 0.00E+00 2.45E+09 6.81E+05 0.00E+00 II.4-126 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-31 (Page 1 of 4)
Teen Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 0.00E+00 C-14 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 0.00E+00 NA-22 1.41E+05 1.41E+05 1.41E+05 1.41E+05 1.41E+05 1.41E+05 1.41E+05 0.00E+00 NA-24 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 0.00E+00 P-32 1.89E+06 1.10E+05 7.16E+04 0.00E+00 0.00E+00 0.00E+00 9.28E+04 0.00E+00 CA-41 3.24E+05 0.00E+00 3.50E+04 0.00E+00 1.08E+06 8.08E+08 2.38E+05 0.00E+00 SC-46 5.79E+05 1.13E+06 3.34E+05 7.50E+01 3.07E+01 2.10E+04 3.00E+03 0.00E+00 CR-51 0.00E+00 0.00E+00 1.35E+02 7.50E+01 3.07E+01 2.10E+04 3.00E+03 0.00E+00 MN-54 0.00E+00 5.11E+04 8.40E+03 0.00E+00 1.27E+04 1.98E+06 6.68E+04 0.00E+00 FE-55 3.34E+04 2.38E+04 5.54E+03 0.00E+00 0.00E+00 1.24E+05 6.39E+03 0.00E+00 MN-56 0.00E+00 1.70E+00 2.52E-01 0.00E+00 1.79E+00 1.52E+04 5.74E+04 0.00E+00 CO-57 0.00E+00 9.44E+02 9.20E+02 0.00E+00 0.00E+00 5.86E+05 3.14E+04 0.00E+00 CO-58 0.00E+00 2.07E+03 2.78E+03 0.00E+00 0.00E+00 1.34E+06 9.52E+04 0.00E+00 FE-59 1.59E+04 3.70E+04 1.43E+04 0.00E+00 0.00E+00 1.53E+06 1.78E+05 0.00E+00 CO-60 0.00E+00 1.51E+04 1.98E+04 0.00E+00 0.00E+00 8.72E+06 2.59E+05 0.00E+00 NI-59 4.35E+04 1.62E+04 7.39E+03 0.00E+00 0.00E+00 1.13E+05 5.18E+03 0.00E+00 NI-63 5.80E+05 4.34E+04 1.98E+04 0.00E+00 0.00E+00 3.07E+05 1.42E+04 0.00E+00 CU-64 0.00E+00 2.03E+00 8.48E-01 0.00E+00 6.41E+00 1.11E+04 6.14E+04 0.00E+00 NI-65 2.18E+00 2.93E-01 1.27E-01 0.00E+00 0.00E+00 9.36E+03 3.67E+04 0.00E+00 ZN-65 3.86E+04 1.34E+05 6.24E+04 0.00E+00 8.64E+04 1.24E+06 4.66E+04 0.00E+00 ZN-69m 1.15E+01 2.47E+01 2.49E+00 0.00E+00 1.65E+01 3.14E+04 1.71E+05 0.00E+00 ZN-69 4.83E-02 9.20E-02 6.46E-03 0.00E+00 6.02E-02 1.58E+03 2.85E+02 0.00E+00 SE-79 0.00E+00 4.34E+03 6.97E+02 0.00E+00 6.50E+03 6.17E+05 2.82E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 1.82E+04 0.00E+00 0.00E+00 0.00E+00 8.00E-15 0.00E+00 BR-83 0.00E+00 0.00E+00 3.44E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 4.33E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.83E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.90E+05 8.40E+04 0.00E+00 0.00E+00 0.00E+00 1.77E+04 0.00E+00 RB-87 0.00E+00 1.12E+05 3.66E+04 0.00E+00 0.00E+00 0.00E+00 2.44E+03 0.00E+00 RB-88 0.00E+00 5.46E+02 2.72E+02 0.00E+00 0.00E+00 0.00E+00 2.92E-05 0.00E+00 RB-89 0.00E+00 3.52E+02 2.33E+02 0.00E+00 0.00E+00 0.00E+00 3.38E-07 0.00E+00 SR-89 4.34E+05 0.00E+00 1.25E+04 0.00E+00 0.00E+00 2.42E+06 3.71E+05 0.00E+00 SR-90 1.08E+08 0.00E+00 6.68E+06 0.00E+00 0.00E+00 1.65E+07 7.65E+05 0.00E+00 Y-90 2.98E+03 0.00E+00 8.00E+01 0.00E+00 0.00E+00 2.93E+05 5.59E+05 0.00E+00 SR-91 8.80E+01 0.00E+00 3.51E+00 0.00E+00 0.00E+00 6.07E+04 2.59E+05 0.00E+00 Y-91m 3.70E-01 0.00E+00 1.42E-02 0.00E+00 0.00E+00 3.20E+03 3.02E+01 0.00E+00 Y-91 6.61E+05 0.00E+00 1.77E+04 0.00E+00 0.00E+00 2.94E+06 4.09E+05 0.00E+00 II.4-127 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-31 (Page 2 of 4)
Teen Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 9.52E+00 0.00E+00 4.06E-01 0.00E+00 0.00E+00 2.74E+04 1.19E+05 0.00E+00 Y-92 1.47E+01 0.00E+00 4.29E-01 0.00E+00 0.00E+00 2.68E+04 1.65E+05 0.00E+00 Y-93 1.35E+02 0.00E+00 3.72E+00 0.00E+00 0.00E+00 8.32E+04 5.79E+05 0.00E+00 NB-93m 3.31E+05 1.09E+05 2.73E+04 0.00E+00 1.27E+05 4.29E+05 2.02E+04 0.00E+00 NB-95 1.86E+04 1.03E+04 5.66E+03 0.00E+00 1.00E+04 7.51E+05 9.68E+04 0.00E+00 NB-97 3.14E-01 7.78E-02 2.84E-02 0.00E+00 9.12E-02 3.93E+03 2.17E+03 0.00E+00 ZR-93 5.46E+05 2.70E+05 1.47E+05 0.00E+00 9.28E+05 2.94E+06 1.28E+05 0.00E+00 ZR-95 1.46E+05 4.58E+04 3.15E+04 0.00E+00 6.74E+04 2.69E+06 1.49E+05 0.00E+00 ZR-97 1.38E+02 2.72E+01 1.26E+01 0.00E+00 4.12E+01 1.30E+05 6.30E+05 0.00E+00 MO-93 0.00E+00 1.33E+04 3.62E+02 0.00E+00 4.05E+03 7.05E+05 3.19E+04 0.00E+00 MO-99 0.00E+00 1.69E+02 3.22E+01 0.00E+00 4.11E+02 1.54E+05 2.69E+05 0.00E+00 TC-99 3.58E+02 5.26E+02 1.43E+02 0.00E+00 6.68E+03 1.39E+06 6.39E+04 0.00E+00 TC-99m 1.38E-03 3.86E-03 4.99E-02 0.00E+00 5.76E-02 1.15E+03 6.13E+03 0.00E+00 TC-101 5.92E-05 8.40E-05 8.24E-04 0.00E+00 1.52E-03 6.67E+02 8.72E-07 0.00E+00 RU-103 2.10E+03 0.00E+00 8.96E+02 0.00E+00 7.43E+03 7.83E+05 1.09E+05 0.00E+00 RU-105 1.12E+00 0.00E+00 4.34E-01 0.00E+00 1.41E+00 1.82E+04 9.04E+04 0.00E+00 RU-106 9.84E+04 0.00E+00 1.24E+04 0.00E+00 1.90E+05 1.61E+07 9.60E+05 0.00E+00 RH-105 1.06E+01 7.58E+00 4.99E+00 0.00E+00 3.23E+01 3.27E+04 9.84E+04 0.00E+00 PD-107 0.00E+00 9.36E+02 6.71E+01 0.00E+00 7.51E+03 1.30E+05 5.99E+03 0.00E+00 PD-109 0.00E+00 5.25E+00 1.33E+00 0.00E+00 2.69E+01 2.55E+04 1.57E+05 0.00E+00 AG-110m 1.38E+04 1.31E+04 7.99E+03 0.00E+00 2.50E+04 6.75E+06 2.73E+05 0.00E+00 AG-111 4.86E+02 2.02E+02 1.02E+02 0.00E+00 6.54E+02 3.20E+05 2.40E+05 0.00E+00 CD-113m 0.00E+00 1.74E+06 5.68E+04 0.00E+00 1.94E+06 2.87E+06 1.34E+05 0.00E+00 CD-115m 0.00E+00 2.78E+05 9.12E+03 0.00E+00 2.26E+05 2.42E+06 4.08E+05 0.00E+00 SN-123 3.45E+05 7.55E+03 1.12E+04 6.04E+03 0.00E+00 3.97E+05 3.33E+05 0.00E+00 SN-125 1.33E+04 3.54E+02 7.99E+02 2.76E+02 0.00E+00 1.01E+06 5.83E+05 0.00E+00 SN-126 1.74E+06 4.31E+04 6.59E+04 1.14E+04 0.00E+00 1.38E+07 1.34E+05 0.00E+00 SB-124 4.30E+04 7.94E+02 1.68E+04 9.76E+01 0.00E+00 3.85E+06 3.98E+05 0.00E+00 SB-125 7.38E+04 8.08E+02 1.72E+04 7.04E+01 0.00E+00 2.74E+06 9.92E+04 0.00E+00 SB-126 4.95E+03 1.02E+02 1.78E+03 2.80E+01 0.00E+00 1.24E+06 4.81E+05 0.00E+00 SB-127 3.71E+02 7.94E+00 1.40E+02 4.17E+00 0.00E+00 2.65E+05 3.15E+05 0.00E+00 TE-125m 4.88E+03 2.24E+03 6.67E+02 1.40E+03 0.00E+00 5.36E+05 7.50E+04 0.00E+00 TE-127m 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 0.00E+00 TE-127 2.01E+00 9.12E-01 4.42E-01 1.42E+00 7.28E+00 1.12E+04 8.08E+04 0.00E+00 TE-129m 1.39E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06 4.05E+05 0.00E+00 TE-129 7.10E-02 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 1.62E+03 0.00E+00 TE-133m 8.08E-02 5.86E-02 4.57E-02 6.54E-02 2.46E-01 6.97E+03 9.84E+02 0.00E+00 II.4-128 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-31 (Page 3 of 4)
Teen Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 4.25E-02 3.48E-02 2.91E-02 3.57E-02 2.33E-01 5.38E+03 1.10E+01 0.00E+00 I-129 2.82E+04 2.35E+04 7.12E+04 2.93E+07 4.21E+04 0.00E+00 1.83E+03 0.00E+00 I-130 6.24E+03 1.79E+04 7.17E+03 1.49E+06 2.75E+04 0.00E+00 9.12E+03 0.00E+00 I-131 3.54E+04 4.91E+04 2.64E+04 1.46E+07 8.40E+04 0.00E+00 6.49E+03 0.00E+00 TE-131m 9.84E+01 6.01E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 6.21E+05 0.00E+00 TE-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51E+01 0.00E+00 I-132 1.59E+03 4.38E+03 1.58E+03 1.51E+05 6.92E+03 0.00E+00 1.27E+03 0.00E+00 TE-132 3.60E+02 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 0.00E+00 I-133 1.22E+04 2.05E+04 6.22E+03 2.92E+06 3.59E+04 0.00E+00 1.03E+04 0.00E+00 CS-134m 1.76E+02 3.48E+02 1.88E+02 0.00E+00 2.03E+02 3.65E+01 1.62E+02 0.00E+00 CS-134 5.02E+05 1.13E+06 5.49E+05 0.00E+00 3.75E+05 1.46E+05 9.76E+03 0.00E+00 I-134 8.88E+02 2.32E+03 8.40E+02 3.95E+04 3.66E+03 0.00E+00 2.04E+01 0.00E+00 I-135 3.70E+03 9.44E+03 3.49E+03 6.21E+05 1.49E+04 0.00E+00 6.95E+03 0.00E+00 CS-135 1.66E+05 1.46E+05 3.58E+04 0.00E+00 5.84E+04 2.16E+04 1.78E+03 0.00E+00 CS-136 5.15E+04 1.94E+05 1.37E+05 0.00E+00 1.10E+05 1.78E+04 1.09E+04 0.00E+00 CS-137 6.70E+05 8.48E+05 3.11E+05 0.00E+00 3.04E+05 1.21E+05 8.48E+03 0.00E+00 CS-138 4.66E+02 8.56E+02 4.46E+02 0.00E+00 6.62E+02 7.87E+01 2.70E-01 0.00E+00 CS-139 2.92E+02 4.10E+02 1.58E+02 0.00E+00 3.47E+02 3.89E+01 1.33E-13 0.00E+00 BA-139 1.34E+00 9.44E-04 3.90E-02 0.00E+00 8.88E-04 6.46E+03 6.45E+03 0.00E+00 BA-140 5.47E+04 6.70E+01 3.52E+03 0.00E+00 2.28E+01 2.03E+06 2.29E+05 0.00E+00 LA-140 4.79E+02 2.36E+02 6.26E+01 0.00E+00 0.00E+00 2.14E+05 4.87E+05 0.00E+00 BA-141 1.42E-01 1.06E-04 4.74E-03 0.00E+00 9.84E-05 3.29E+03 7.46E-04 0.00E+00 LA-141 6.10E+00 1.88E+00 3.10E-01 0.00E+00 0.00E+00 1.85E+04 1.23E+05 0.00E+00 CE-141 2.84E+04 1.90E+04 2.17E+03 0.00E+00 8.88E+03 6.14E+05 1.26E+05 0.00E+00 BA-142 3.70E-02 3.70E-05 2.27E-03 0.00E+00 3.14E-05 1.91E+03 4.79E-10 0.00E+00 LA-142 9.60E-01 4.25E-01 1.06E-01 0.00E+00 0.00E+00 1.02E+04 1.20E+04 0.00E+00 CE-143 2.66E+02 1.94E+02 2.16E+01 0.00E+00 8.64E+01 1.30E+05 2.55E+05 0.00E+00 PR-143 1.34E+04 5.31E+03 6.62E+02 0.00E+00 3.09E+03 4.83E+05 2.14E+05 0.00E+00 CE-144 4.89E+06 2.02E+06 2.62E+05 0.00E+00 1.21E+06 1.34E+07 8.64E+05 0.00E+00 PR-144 4.30E-02 1.76E-02 2.18E-03 0.00E+00 1.01E-02 1.75E+03 2.35E-04 0.00E+00 ND-147 7.86E+03 8.56E+03 5.13E+02 0.00E+00 5.02E+03 3.72E+05 1.82E+05 0.00E+00 PM-147 9.20E+05 8.80E+04 3.60E+04 0.00E+00 1.68E+05 9.12E+05 4.70E+04 0.00E+00 PM-148m 1.06E+05 2.68E+04 2.10E+04 0.00E+00 4.06E+04 2.56E+06 3.28E+05 0.00E+00 PM-148 4.35E+03 7.10E+02 3.58E+02 0.00E+00 1.28E+03 5.22E+05 4.91E+05 0.00E+00 PM-149 3.93E+02 5.51E+01 2.27E+01 0.00E+00 1.05E+02 9.92E+04 2.23E+05 0.00E+00 PM-151 9.60E+01 1.59E+01 8.08E+00 0.00E+00 2.86E+01 4.52E+04 1.82E+05 0.00E+00 SM-151 8.56E+05 1.68E+05 3.89E+04 0.00E+00 1.82E+05 6.14E+05 2.82E+04 0.00E+00 II.4-129 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-31 (Page 4 of 4)
Teen Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.94E+02 1.61E+02 1.18E+01 0.00E+00 5.25E+01 5.69E+04 1.42E+05 0.00E+00 EU-152 2.37E+06 5.75E+05 5.04E+05 0.00E+00 2.67E+06 4.01E+06 1.08E+05 0.00E+00 EU-154 7.54E+06 9.84E+05 6.88E+05 0.00E+00 4.35E+06 7.30E+06 2.67E+05 0.00E+00 EU-155 1.60E+06 1.57E+05 9.68E+04 0.00E+00 6.12E+05 1.21E+07 4.78E+05 0.00E+00 EU-156 2.16E+04 1.62E+04 2.64E+03 0.00E+00 1.09E+04 1.10E+06 3.65E+05 0.00E+00 TB-160 2.43E+05 0.00E+00 3.03E+04 0.00E+00 9.60E+04 3.18E+06 2.08E+05 0.00E+00 HO-166m 3.52E+06 1.25E+06 7.90E+05 0.00E+00 1.60E+06 4.99E+06 1.34E+05 0.00E+00 W-181 7.12E+01 2.30E+01 2.41E+00 0.00E+00 0.00E+00 2.36E+04 2.15E+03 0.00E+00 W-185 2.22E+03 7.34E+02 7.78E+01 0.00E+00 0.00E+00 7.68E+05 9.12E+04 0.00E+00 W-187 1.20E+01 9.76E+00 3.43E+00 0.00E+00 0.00E+00 4.74E+04 1.77E+05 0.00E+00 NP-239 3.38E+02 3.19E+01 1.77E+01 0.00E+00 1.00E+02 6.49E+04 1.32E+05 0.00E+00 U-232 5.85E+08 0.00E+00 4.18E+07 0.00E+00 6.35E+07 3.07E+09 3.57E+05 0.00E+00 U-233 1.24E+08 0.00E+00 7.54E+06 0.00E+00 2.90E+07 7.34E+08 3.30E+05 0.00E+00 U-234 1.18E+08 0.00E+00 7.38E+06 0.00E+00 2.84E+07 7.19E+08 3.23E+05 0.00E+00 U-235 1.14E+08 0.00E+00 6.94E+06 0.00E+00 2.67E+07 6.75E+08 4.10E+05 0.00E+00 U-236 1.14E+08 0.00E+00 7.09E+06 0.00E+00 2.73E+07 6.90E+08 3.03E+05 0.00E+00 U-237 4.20E+02 0.00E+00 1.12E+02 0.00E+00 1.73E+03 1.41E+05 1.03E+05 0.00E+00 U-238 1.09E+08 0.00E+00 6.48E+06 0.00E+00 2.50E+07 6.31E+08 2.90E+05 0.00E+00 NP-237 1.31E+10 8.48E+09 5.77E+08 0.00E+00 4.28E+09 7.19E+08 4.18E+05 0.00E+00 NP-238 3.38E+03 8.16E+02 5.27E+01 0.00E+00 3.10E+02 1.40E+05 1.90E+05 0.00E+00 PU-238 1.20E+10 8.24E+09 5.78E+08 0.00E+00 2.48E+09 2.50E+09 3.83E+05 0.00E+00 PU-239 1.38E+10 8.96E+09 6.44E+08 0.00E+00 2.75E+09 2.34E+09 3.50E+05 0.00E+00 PU-240 1.38E+10 8.96E+09 6.43E+08 0.00E+00 2.74E+09 2.34E+09 3.57E+05 0.00E+00 PU-241 2.99E+08 7.65E+07 1.12E+07 0.00E+00 5.18E+07 2.08E+06 7.34E+03 0.00E+00 PU-242 1.28E+10 8.64E+09 6.20E+08 0.00E+00 2.65E+09 2.26E+09 3.43E+05 0.00E+00 PU-244 1.50E+10 9.92E+09 7.10E+08 0.00E+00 3.03E+09 2.58E+09 5.11E+05 0.00E+00 AM-241 1.42E+10 9.60E+09 5.68E+08 0.00E+00 4.26E+09 8.40E+08 3.90E+05 0.00E+00 AM-242m 1.43E+10 9.04E+09 5.72E+08 0.00E+00 4.24E+09 3.37E+08 4.91E+05 0.00E+00 AM-243 1.42E+10 9.36E+09 5.56E+08 0.00E+00 4.17E+09 7.93E+08 4.58E+05 0.00E+00 CM-242 2.54E+08 2.01E+08 1.13E+07 0.00E+00 5.12E+07 5.41E+08 4.17E+05 0.00E+00 CM-243 9.52E+09 6.64E+09 4.00E+08 0.00E+00 1.87E+09 8.72E+08 4.10E+05 0.00E+00 CM-244 7.35E+09 5.22E+09 3.10E+08 0.00E+00 1.45E+09 8.40E+08 3.97E+05 0.00E+00 CM-245 1.46E+10 9.76E+09 6.02E+08 0.00E+00 2.82E+09 8.08E+08 3.70E+05 0.00E+00 CM-246 1.45E+10 9.76E+09 6.02E+08 0.00E+00 2.81E+09 8.24E+08 3.63E+05 0.00E+00 CM-247 1.42E+10 9.52E+09 5.93E+08 0.00E+00 2.77E+09 8.08E+08 4.78E+05 0.00E+00 CM-248 1.18E+11 7.86E+10 4.89E+09 0.00E+00 2.28E+10 6.66E+09 7.70E+06 0.00E+00 CF-252 5.73E+09 0.00E+00 2.46E+08 0.00E+00 0.00E+00 2.74E+09 1.51E+06 0.00E+00 II.4-130 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-32 (Page 1 of 4)
Adult Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 0.00E+00 C-14 1.82E+04 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 0.00E+00 NA-22 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 0.00E+00 NA-24 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 0.00E+00 P-32 1.32E+06 7.71E+04 5.01E+04 0.00E+00 0.00E+00 0.00E+00 8.64E+04 0.00E+00 CA-41 3.06E+05 0.00E+00 3.30E+04 0.00E+00 0.00E+00 3.06E+04 2.29E+03 0.00E+00 SC-46 4.41E+05 8.56E+05 2.49E+05 0.00E+00 7.99E+05 0.00E+00 2.58E+05 0.00E+00 CR-51 0.00E+00 0.00E+00 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 0.00E+00 MN-54 0.00E+00 3.96E+04 6.30E+03 0.00E+00 9.84E+03 1.40E+06 7.74E+04 0.00E+00 FE-55 2.46E+04 1.70E+04 3.94E+03 0.00E+00 0.00E+00 7.21E+04 6.03E+03 0.00E+00 MN-56 0.00E+00 1.24E+00 1.83E-01 0.00E+00 1.30E+00 9.44E+03 2.02E+04 0.00E+00 CO-57 0.00E+00 6.92E+02 6.71E+02 0.00E+00 0.00E+00 3.70E+05 3.14E+04 0.00E+00 CO-58 0.00E+00 1.58E+03 2.07E+03 0.00E+00 0.00E+00 9.28E+05 1.06E+05 0.00E+00 FE-59 1.18E+04 2.78E+04 1.06E+04 0.00E+00 0.00E+00 1.02E+06 1.88E+05 0.00E+00 CO-60 0.00E+00 1.15E+04 1.48E+04 0.00E+00 0.00E+00 5.97E+06 2.85E+05 0.00E+00 NI-59 3.25E+04 1.17E+04 5.42E+03 0.00E+00 0.00E+00 6.56E+04 4.89E+03 0.00E+00 NI-63 4.32E+05 3.14E+04 1.45E+04 0.00E+00 0.00E+00 1.78E+05 1.34E+04 0.00E+00 CU-64 0.00E+00 1.46E+00 6.15E-01 0.00E+00 4.62E+00 6.78E+03 4.90E+04 0.00E+00 NI-65 1.54E+00 2.10E-01 9.12E-02 0.00E+00 0.00E+00 5.60E+03 1.23E+04 0.00E+00 ZN-65 3.24E+04 1.03E+05 4.66E+04 0.00E+00 6.90E+04 8.64E+05 5.34E+04 0.00E+00 ZN-69m 8.16E+00 1.96E+01 1.79E+00 0.00E+00 1.18E+01 1.90E+04 1.37E+05 0.00E+00 ZN-69 3.38E-02 6.51E-02 4.52E-03 0.00E+00 4.22E-02 9.20E+02 1.63E+01 0.00E+00 SE-79 0.00E+00 3.06E+03 4.87E+02 0.00E+00 4.55E+03 3.58E+05 2.66E+04 0.00E+00 BR-82 0.00E+00 0.00E+00 1.35E+04 0.00E+00 0.00E+00 0.00E+00 1.04E+04 0.00E+00 BR-83 0.00E+00 0.00E+00 2.41E+02 0.00E+00 0.00E+00 0.00E+00 2.32E+02 0.00E+00 BR-84 0.00E+00 0.00E+00 3.13E+02 0.00E+00 0.00E+00 0.00E+00 1.64E-03 0.00E+00 BR-85 0.00E+00 0.00E+00 1.28E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 1.35E+05 5.90E+04 0.00E+00 0.00E+00 0.00E+00 1.66E+04 0.00E+00 RB-87 0.00E+00 3.87E+02 2.57E+04 0.00E+00 0.00E+00 0.00E+00 2.30E+03 0.00E+00 RB-88 0.00E+00 3.87E+02 1.93E+02 0.00E+00 0.00E+00 0.00E+00 3.34E-09 0.00E+00 RB-89 0.00E+00 2.56E+02 1.70E+02 0.00E+00 0.00E+00 0.00E+00 9.28E-12 0.00E+00 SR-89 3.04E+05 0.00E+00 8.72E+03 0.00E+00 0.00E+00 1.40E+06 3.50E+05 0.00E+00 SR-90 9.92E+07 0.00E+00 6.10E+06 0.00E+00 0.00E+00 9.60E+06 7.22E+05 0.00E+00 Y-90 2.09E+03 0.00E+00 5.61E+01 0.00E+00 0.00E+00 1.70E+05 5.06E+05 0.00E+00 SR-91 6.19E+01 0.00E+00 2.50E+00 0.00E+00 0.00E+00 3.65E+04 1.91E+05 0.00E+00 Y-91m 2.61E-01 0.00E+00 1.02E-02 0.00E+00 0.00E+00 1.92E+03 1.33E+00 0.00E+00 Y-91 4.62E+05 0.00E+00 1.24E+04 0.00E+00 0.00E+00 1.70E+06 3.85E+05 0.00E+00 II.4-131 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-32 (Page 2 of 4)
Adult Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 6.74E+00 0.00E+00 2.91E-01 0.00E+00 0.00E+00 1.65E+04 4.30E+04 0.00E+00 Y-92 1.03E+01 0.00E+00 3.02E-01 0.00E+00 0.00E+00 1.57E+04 7.35E+04 0.00E+00 Y-93 9.44E+01 0.00E+00 2.61E+00 0.00E+00 0.00E+00 4.85E+04 4.22E+05 0.00E+00 NB-93m 2.48E+05 8.08E+04 1.99E+04 0.00E+00 9.28E+04 2.49E+05 1.90E+04 0.00E+00 NB-95 1.41E+04 7.82E+03 4.21E+03 0.00E+00 7.74E+03 5.05E+05 1.04E+05 0.00E+00 NB-97 2.22E-01 5.62E-02 2.05E-02 0.00E+00 6.54E-02 2.40E+03 2.42E+02 0.00E+00 ZR-93 4.18E+05 2.34E+04 1.10E+04 0.00E+00 8.88E+04 1.70E+05 1.21E+04 0.00E+00 ZR-95 1.07E+05 3.44E+04 2.33E+04 0.00E+00 5.42E+04 1.77E+06 1.50E+05 0.00E+00 ZR-97 9.68E+01 1.96E+01 9.04E+00 0.00E+00 2.97E+01 7.87E+04 5.23E+05 0.00E+00 MO-93 0.00E+00 9.36E+03 2.54E+02 0.00E+00 2.84E+03 4.09E+05 3.03E+04 0.00E+00 MO-99 0.00E+00 1.21E+02 2.30E+01 0.00E+00 2.91E+02 9.12E+04 2.48E+05 0.00E+00 TC-99 2.50E+02 3.71E+02 1.00E+02 0.00E+00 4.68E+03 8.08E+05 6.03E+04 0.00E+00 TC-99m 1.03E-03 2.91E-03 3.70E-02 0.00E+00 4.42E-02 7.64E+02 4.16E+03 0.00E+00 TC-101 4.18E-05 6.02E-05 5.90E-04 0.00E+00 1.08E-03 3.99E+02 1.09E-11 0.00E+00 RU-103 1.53E+03 0.00E+00 6.58E+02 0.00E+00 5.83E+03 5.05E+05 1.10E+05 0.00E+00 RU-105 7.90E-01 0.00E+00 3.11E-01 0.00E+00 1.02E+00 1.10E+04 4.82E+04 0.00E+00 RU-106 6.91E+04 0.00E+00 8.72E+03 0.00E+00 1.34E+05 9.36E+06 9.12E+05 0.00E+00 RH-105 7.39E+00 5.38E+00 3.54E+00 0.00E+00 2.29E+01 1.93E+04 8.72E+04 0.00E+00 PD-107 0.00E+00 6.62E+02 4.70E+01 0.00E+00 5.26E+03 7.58E+04 5.65E+03 0.00E+00 PD-109 0.00E+00 3.70E+00 9.28E-01 0.00E+00 1.88E+01 1.48E+04 1.22E+05 0.00E+00 AG-110m 1.08E+04 1.00E+04 5.94E+03 0.00E+00 1.97E+04 4.63E+06 3.02E+05 0.00E+00 AG-111 3.40E+02 1.42E+02 7.10E+01 0.00E+00 4.59E+02 1.86E+05 2.23E+05 0.00E+00 CD-113m 0.00E+00 1.23E+06 3.98E+04 0.00E+00 1.37E+06 1.66E+06 1.27E+05 0.00E+00 CD-115m 0.00E+00 1.97E+05 6.36E+03 0.00E+00 1.58E+05 1.41E+06 3.84E+05 0.00E+00 SN-123 2.42E+05 5.34E+03 7.86E+03 4.54E+03 0.00E+00 2.30E+06 3.14E+05 0.00E+00 SN-125 9.28E+03 2.50E+02 5.62E+02 2.07E+02 0.00E+00 5.90E+05 5.45E+05 0.00E+00 SN-126 1.26E+06 3.34E+04 4.80E+04 9.84E+03 0.00E+00 9.36E+06 1.27E+05 0.00E+00 SB-124 3.12E+04 5.89E+02 1.22E+04 7.55E+01 0.00E+00 2.48E+06 4.06E+05 0.00E+00 SB-125 5.34E+04 5.95E+02 1.26E+04 5.40E+01 0.00E+00 1.74E+06 1.01E+05 0.00E+00 SB-126 3.60E+03 7.30E+01 1.30E+03 2.20E+01 0.00E+00 7.66E+05 4.81E+05 0.00E+00 SB-127 2.64E+02 5.78E+00 1.02E+02 3.18E+00 0.00E+00 1.64E+05 3.02E+05 0.00E+00 TE-125m 3.42E+03 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 0.00E+00 TE-127m 1.26E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 0.00E+00 TE-127 1.40E+00 6.42E-01 3.10E-01 1.06E+00 5.10E+00 6.51E+03 5.74E+04 0.00E+00 TE-129m 9.76E+03 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 0.00E+00 TE-129 4.98E-02 2.39E-02 1.24E-02 3.90E-02 1.87E-01 1.94E+03 1.57E+02 0.00E+00 TE-133m 5.79E-02 4.32E-02 3.34E-02 5.02E-02 2.99E-01 4.41E+03 4.39E+02 0.00E+00 II.4-132 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-32 (Page 3 of 4)
Adult Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 3.07E-02 2.58E-02 1.26E-02 2.75E-02 1.74E-01 3.47E+03 2.38E-01 0.00E+00 I-129 1.98E+04 1.69E+04 5.53E+04 4.43E+07 3.62E+04 0.00E+00 1.78E+03 0.00E+00 I-130 4.58E+03 1.34E+04 5.28E+03 1.14E+06 2.09E+04 0.00E+00 7.69E+03 0.00E+00 I-131 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 0.00E+00 6.28E+03 0.00E+00 TE-131m 6.99E+01 4.36E+01 2.90E+01 5.50E+01 3.09E+02 1.46E+05 5.56E+05 0.00E+00 TE-131 1.11E-02 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 0.00E+00 I-132 1.16E+03 3.26E+03 1.16E+03 1.14E+05 5.18E+03 0.00E+00 4.06E+02 0.00E+00 TE-132 2.60E+02 2.15E+02 1.62E+02 1.90E+02 1.46E+03 2.88E+05 5.10E+05 0.00E+00 I-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 0.00E+00 8.88E+03 0.00E+00 CS-134m 1.27E+02 2.56E+02 1.38E+02 0.00E+00 1.46E+02 2.34E+01 6.34E+01 0.00E+00 CS-134 3.73E+05 8.48E+05 7.28E+05 0.00E+00 2.87E+05 9.76E+04 1.04E+04 0.00E+00 I-134 6.44E+02 1.73E+03 6.15E+02 2.98E+04 2.75E+03 0.00E+00 1.01E+00 0.00E+00 I-135 2.68E+03 6.98E+03 2.57E+03 4.48E+05 1.11E+04 0.00E+00 5.25E+03 0.00E+00 CS-135 1.17E+05 1.03E+05 4.79E+04 0.00E+00 4.09E+04 1.26E+04 1.69E+03 0.00E+00 CS-136 3.90E+04 1.46E+05 1.10E+05 0.00E+00 8.56E+04 1.20E+04 1.17E+04 0.00E+00 CS-137 4.78E+05 6.21E+05 4.28E+05 0.00E+00 2.22E+05 7.52E+04 8.40E+03 0.00E+00 CS-138 3.31E+02 6.21E+02 3.24E+02 0.00E+00 4.80E+02 4.86E+01 1.86E-03 0.00E+00 CS-139 2.05E+02 2.90E+02 1.11E+02 0.00E+00 2.44E+02 2.27E+01 4.39E-21 0.00E+00 BA-139 9.36E-01 6.66E-04 2.74E-02 0.00E+00 6.22E-04 3.76E+03 8.96E+02 0.00E+00 BA-140 3.90E+04 4.90E+01 2.57E+03 0.00E+00 1.67E+01 1.27E+06 2.18E+05 0.00E+00 LA-140 3.44E+02 1.74E+02 4.58E+01 0.00E+00 0.00E+00 1.36E+05 4.58E+05 0.00E+00 BA-141 1.00E-01 7.53E-05 3.36E-03 0.00E+00 7.00E-05 1.94E+03 1.16E-07 0.00E+00 LA-141 4.27E+00 1.33E+00 2.17E-01 0.00E+00 0.00E+00 1.08E+04 5.85E+04 0.00E+00 CE-141 1.99E+04 1.35E+04 1.53E+03 0.00E+00 6.26E+03 3.62E+05 1.20E+05 0.00E+00 BA-142 2.63E-02 2.70E-05 1.66E-03 0.00E+00 2.29E-05 1.19E+03 1.57E-16 0.00E+00 LA-142 6.83E-01 3.10E-01 7.72E-02 0.00E+00 0.00E+00 6.33E+03 2.11E+03 0.00E+00 CE-143 1.86E+02 1.38E+02 1.53E+01 0.00E+00 6.08E+01 7.98E+04 2.26E+05 0.00E+00 PR-143 9.36E+03 3.75E+03 4.64E+02 0.00E+00 2.16E+03 2.81E+05 2.00E+05 0.00E+00 CE-144 3.43E+06 1.43E+06 1.84E+05 0.00E+00 8.48E+05 7.78E+06 8.16E+05 0.00E+00 PR-144 3.01E-02 1.25E-02 1.53E-03 0.00E+00 7.05E-03 1.02E+03 2.15E-08 0.00E+00 ND-147 5.27E+03 6.10E+03 3.65E+02 0.00E+00 3.56E+03 2.21E+05 1.73E+05 0.00E+00 PM-147 6.70E+05 6.30E+04 2.55E+04 0.00E+00 1.19E+05 5.28E+05 4.43E+04 0.00E+00 PM-148m 7.86E+04 2.03E+04 1.55E+04 0.00E+00 3.08E+04 1.71E+06 3.34E+05 0.00E+00 PM-148 3.07E+03 5.10E+02 2.56E+02 0.00E+00 9.60E+02 3.13E+05 4.64E+05 0.00E+00 PM-149 2.75E+02 3.90E+01 1.59E+01 0.00E+00 7.35E+01 5.77E+04 2.00E+05 0.00E+00 PM-151 6.80E+01 1.14E+01 5.77E+00 0.00E+00 2.04E+01 3.15E+04 1.60E+05 0.00E+00 SM-151 6.87E+05 1.18E+05 2.84E+04 0.00E+00 1.33E+05 3.56E+05 2.60E+04 0.00E+00 II.4-133 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-32 (Page 4 of 4)
Adult Inhalation Ri mrem*m3/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.36E+02 1.14E+02 8.32E+00 0.00E+00 3.67E+01 3.31E+04 1.26E+05 0.00E+00 EU-152 1.90E+06 4.33E+05 3.81E+05 0.00E+00 2.68E+06 2.74E+06 1.27E+05 0.00E+00 EU-154 5.92E+06 7.28E+05 5.18E+05 0.00E+00 3.49E+06 4.67E+06 2.72E+05 0.00E+00 EU-155 8.08E+05 1.14E+05 7.37E+04 0.00E+00 5.27E+05 7.57E+05 4.76E+04 0.00E+00 EU-156 1.54E+04 1.18E+04 1.92E+03 0.00E+00 7.96E+03 6.85E+05 3.60E+05 0.00E+00 TB-160 1.77E+05 0.00E+00 2.20E+04 0.00E+00 7.28E+04 1.54E+06 2.14E+05 0.00E+00 HO-166m 2.70E+06 8.40E+05 6.40E+05 0.00E+00 1.26E+06 3.15E+06 1.27E+05 0.00E+00 W-181 4.98E+01 1.62E+01 1.74E+00 0.00E+00 0.00E+00 1.37E+04 2.02E+03 0.00E+00 W-185 1.56E+03 5.18E+02 5.45E+01 0.00E+00 0.00E+00 4.46E+05 8.56E+04 0.00E+00 W-187 8.48E+00 7.08E+00 2.48E+00 0.00E+00 0.00E+00 2.90E+04 1.55E+05 0.00E+00 NP-239 2.30E+02 2.26E+01 1.24E+01 0.00E+00 7.00E+01 3.76E+04 1.19E+05 0.00E+00 U-232 4.11E+08 0.00E+00 2.93E+07 0.00E+00 4.45E+07 1.78E+09 3.37E+05 0.00E+00 U-233 8.72E+07 0.00E+00 5.28E+06 0.00E+00 2.03E+07 4.26E+08 3.11E+05 0.00E+00 U-234 8.32E+07 0.00E+00 5.17E+06 0.00E+00 1.99E+07 4.18E+08 3.05E+05 0.00E+00 U-235 8.00E+07 0.00E+00 4.86E+06 0.00E+00 1.87E+07 3.92E+08 3.87E+05 0.00E+00 U-236 8.00E+07 0.00E+00 4.96E+06 0.00E+00 1.91E+07 4.00E+08 2.86E+05 0.00E+00 U-237 2.94E+02 0.00E+00 7.82E+01 0.00E+00 1.21E+03 8.16E+04 9.60E+04 0.00E+00 U-238 7.66E+07 0.00E+00 4.54E+06 0.00E+00 1.74E+07 3.66E+08 2.73E+05 0.00E+00 NP-237 1.25E+10 8.00E+09 5.50E+08 0.00E+00 4.08E+09 4.18E+08 3.94E+05 0.00E+00 NP-238 2.37E+03 5.76E+02 3.69E+01 0.00E+00 2.18E+02 8.16E+04 1.70E+05 0.00E+00 PU-238 1.14E+10 7.77E+09 5.52E+08 0.00E+00 2.37E+09 1.46E+09 3.62E+05 0.00E+00 PU-239 1.33E+10 8.56E+09 6.20E+08 0.00E+00 2.64E+09 1.38E+09 3.30E+05 0.00E+00 PU-240 1.32E+10 8.56E+09 6.18E+08 0.00E+00 2.63E+09 1.38E+09 3.37E+05 0.00E+00 PU-241 2.74E+08 6.95E+07 1.03E+07 0.00E+00 4.74E+07 1.22E+06 6.92E+03 0.00E+00 PU-242 1.22E+10 8.24E+09 5.97E+08 0.00E+00 2.54E+09 1.32E+09 3.24E+05 0.00E+00 PU-244 1.43E+10 9.44E+09 6.83E+08 0.00E+00 2.91E+09 1.51E+09 4.82E+05 0.00E+00 AM-241 1.34E+10 9.04E+09 5.37E+08 0.00E+00 4.03E+09 4.85E+08 3.68E+05 0.00E+00 AM-242m 1.36E+10 8.48E+09 5.38E+08 0.00E+00 4.01E+09 1.95E+08 4.63E+05 0.00E+00 AM-243 1.34E+10 8.80E+09 5.26E+08 0.00E+00 3.96E+09 4.60E+08 4.32E+05 0.00E+00 CM-242 1.78E+08 1.42E+08 7.87E+06 0.00E+00 3.58E+07 3.14E+08 3.93E+05 0.00E+00 CM-243 8.80E+09 6.09E+09 3.69E+08 0.00E+00 1.72E+09 5.05E+08 3.87E+05 0.00E+00 CM-244 6.70E+09 4.70E+09 2.81E+08 0.00E+00 1.31E+09 4.85E+08 3.74E+05 0.00E+00 CM-245 1.39E+10 9.12E+09 5.71E+08 0.00E+00 2.66E+09 4.68E+08 3.49E+05 0.00E+00 CM-246 1.38E+10 9.12E+09 5.70E+08 0.00E+00 2.66E+09 4.77E+08 3.43E+05 0.00E+00 CM-247 1.34E+10 8.96E+09 5.62E+08 0.00E+00 2.62E+09 4.68E+08 4.50E+05 0.00E+00 CM-248 1.12E+11 7.41E+10 4.63E+09 0.00E+00 2.16E+10 3.86E+09 7.27E+06 0.00E+00 CF-252 4.34E+09 0.00E+00 1.86E+08 0.00E+00 0.00E+00 1.59E+09 1.42E+06 0.00E+00 II.4-134 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-33 (Page 1 of 4)
Infant Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C-14 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NA-22 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NA-24 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 P-32 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CA-41 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SC-46 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CR-51 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MN-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 FE-55 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MN-56 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-57 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-58 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 FE-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-60 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-63 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CU-64 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-65 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-65 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-69m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-69 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SE-79 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-82 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-87 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-90 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-90 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-91 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-91m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-91 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-135 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-33 (Page 2 of 4)
Infant Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-92 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-93m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-95 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-97 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-95 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-97 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MO-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MO-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-99m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-101 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-103 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-105 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-106 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RH-105 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PD-107 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PD-109 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AG-110m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AG-111 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CD-113m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CD-115m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-123 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-125 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-126 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-124 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-125 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-126 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-127 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-125m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-127m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-127 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-129m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-133m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-136 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-33 (Page 3 of 4)
Infant Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-130 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-131m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-132 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-132 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-133 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-134m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-135 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-135 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-136 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-137 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-138 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-143 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PR-143 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PR-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND-147 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-147 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-148m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-148 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-149 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SM-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-137 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-33 (Page 4 of 4)
Infant Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-152 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-155 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-156 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TB-160 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 HO-166m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-181 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-185 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-187 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-239 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-232 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-233 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-234 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-235 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-236 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-237 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-237 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-239 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-240 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-241 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-242 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-244 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-241 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-242m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-243 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-242 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-243 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-244 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-245 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-246 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-247 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-248 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CF-252 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-138 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-34 (Page 1 of 4)
Child Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 2.29E+03 2.29E+03 2.29E+03 2.29E+03 2.29E+03 2.29E+03 0.00E+00 C-14 3.50E+06 7.01E+05 7.01E+05 7.01E+05 7.01E+05 7.01E+05 7.01E+05 0.00E+00 NA-22 4.09E+09 4.09E+09 4.09E+09 4.09E+09 4.09E+09 4.09E+09 4.09E+09 0.00E+00 NA-24 3.71E+05 3.71E+05 3.71E+05 3.71E+05 3.71E+05 3.71E+05 3.71E+05 0.00E+00 P-32 3.37E+09 1.58E+08 1.30E+08 0.00E+00 0.00E+00 0.00E+00 9.31E+07 0.00E+00 CA-41 2.55E+10 0.00E+00 2.79E+09 0.00E+00 0.00E+00 0.00E+00 1.40E+07 0.00E+00 SC-46 7.85E+05 1.08E+06 4.14E+05 0.00E+00 9.53E+05 0.00E+00 1.57E+09 0.00E+00 CR-51 0.00E+00 0.00E+00 1.17E+05 6.50E+04 1.78E+04 1.19E+05 6.21E+06 0.00E+00 MN-54 0.00E+00 6.65E+08 1.77E+08 0.00E+00 1.86E+08 0.00E+00 5.58E+08 0.00E+00 FE-55 8.01E+08 4.25E+08 1.32E+08 0.00E+00 0.00E+00 2.40E+08 7.87E+07 0.00E+00 MN-56 0.00E+00 1.82E+01 4.11E+00 0.00E+00 2.20E+01 0.00E+00 2.64E+03 0.00E+00 CO-57 0.00E+00 2.99E+07 6.04E+07 0.00E+00 0.00E+00 0.00E+00 2.45E+08 0.00E+00 CO-58 0.00E+00 6.44E+07 1.97E+08 0.00E+00 0.00E+00 0.00E+00 3.76E+08 0.00E+00 FE-59 3.98E+08 6.43E+08 3.20E+08 0.00E+00 0.00E+00 1.86E+08 6.70E+08 0.00E+00 CO-60 0.00E+00 3.78E+08 1.12E+09 0.00E+00 0.00E+00 0.00E+00 2.10E+09 0.00E+00 NI-59 2.96E+09 7.87E+08 5.01E+08 0.00E+00 0.00E+00 0.00E+00 5.22E+07 0.00E+00 NI-63 3.95E+10 2.11E+09 1.34E+09 0.00E+00 0.00E+00 0.00E+00 1.42E+08 0.00E+00 CU-64 0.00E+00 1.09E+04 6.60E+03 0.00E+00 2.64E+04 0.00E+00 5.13E+05 0.00E+00 NI-65 1.02E+02 9.59E+00 5.60E+00 0.00E+00 0.00E+00 0.00E+00 1.17E+03 0.00E+00 ZN-65 8.13E+08 2.16E+09 1.35E+09 0.00E+00 1.36E+09 0.00E+00 3.80E+08 0.00E+00 ZN-69m 3.78E+04 6.44E+04 7.61E+03 0.00E+00 3.74E+04 0.00E+00 2.10E+06 0.00E+00 ZN-69 8.73E-06 1.26E-05 1.17E-06 0.00E+00 7.66E-06 0.00E+00 7.96E-04 0.00E+00 SE-79 0.00E+00 6.20E+08 1.37E+08 0.00E+00 1.01E+09 0.00E+00 4.06E+07 0.00E+00 BR-82 0.00E+00 0.00E+00 2.03E+06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 5.20E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 3.30E-11 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 3.59E-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 4.52E+08 2.78E+08 0.00E+00 0.00E+00 0.00E+00 2.91E+07 0.00E+00 RB-87 0.00E+00 2.90E+09 1.35E+09 0.00E+00 0.00E+00 0.00E+00 4.35E+07 0.00E+00 RB-88 0.00E+00 3.37E-22 2.34E-22 0.00E+00 0.00E+00 0.00E+00 1.65E-23 0.00E+00 RB-89 0.00E+00 3.42E-26 3.04E-26 0.00E+00 0.00E+00 0.00E+00 2.98E-28 0.00E+00 SR-89 3.60E+10 0.00E+00 1.03E+09 0.00E+00 0.00E+00 0.00E+00 1.39E+09 0.00E+00 SR-90 1.87E+12 0.00E+00 3.77E+10 0.00E+00 0.00E+00 0.00E+00 1.67E+10 0.00E+00 Y-90 2.30E+04 0.00E+00 6.17E+02 0.00E+00 0.00E+00 0.00E+00 6.56E+07 0.00E+00 SR-91 5.20E+05 0.00E+00 1.96E+04 0.00E+00 0.00E+00 0.00E+00 1.15E+06 0.00E+00 Y-91m 8.12E-09 0.00E+00 2.95E-10 0.00E+00 0.00E+00 0.00E+00 1.59E-05 0.00E+00 Y-91 1.86E+07 0.00E+00 4.99E+05 0.00E+00 0.00E+00 0.00E+00 2.48E+09 0.00E+00 II.4-139 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-34 (Page 2 of 4)
Child Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 7.07E+02 0.00E+00 2.84E+01 0.00E+00 0.00E+00 0.00E+00 1.34E+04 0.00E+00 Y-92 1.55E+00 0.00E+00 4.43E-02 0.00E+00 0.00E+00 0.00E+00 4.48E+04 0.00E+00 Y-93 2.91E+02 0.00E+00 7.98E+00 0.00E+00 0.00E+00 0.00E+00 4.34E+06 0.00E+00 NB-93m 7.64E+06 1.91E+06 6.27E+05 0.00E+00 2.06E+06 0.00E+00 2.87E+08 0.00E+00 NB-95 4.10E+05 1.60E+05 1.14E+05 0.00E+00 1.50E+05 0.00E+00 2.96E+08 0.00E+00 NB-97 3.41E-06 6.16E-07 2.88E-07 0.00E+00 6.84E-07 0.00E+00 1.90E-01 0.00E+00 ZR-93 1.23E+07 4.59E+06 3.27E+06 0.00E+00 1.78E+07 0.00E+00 1.74E+09 0.00E+00 ZR-95 3.86E+06 8.48E+05 7.55E+05 0.00E+00 1.21E+06 0.00E+00 8.85E+08 0.00E+00 ZR-97 5.68E+02 8.20E+01 4.84E+01 0.00E+00 1.18E+02 0.00E+00 1.24E+07 0.00E+00 MO-93 0.00E+00 1.77E+09 6.36E+07 0.00E+00 4.67E+08 0.00E+00 8.97E+07 0.00E+00 MO-99 0.00E+00 7.70E+06 1.91E+06 0.00E+00 1.64E+07 0.00E+00 6.37E+06 0.00E+00 TC-99 3.93E+07 4.38E+07 1.57E+07 0.00E+00 5.16E+08 3.87E+06 4.59E+08 0.00E+00 TC-99m 4.65E+00 9.12E+00 1.51E+02 0.00E+00 1.32E+02 4.63E+00 5.19E+03 0.00E+00 TC-101 1.02E-30 1.06E-30 1.35E-29 0.00E+00 1.81E-29 5.62E-31 3.38E-30 0.00E+00 RU-103 1.53E+07 0.00E+00 5.90E+06 0.00E+00 3.86E+07 0.00E+00 3.97E+08 0.00E+00 RU-105 9.01E+01 0.00E+00 3.27E+01 0.00E+00 7.92E+02 0.00E+00 5.88E+04 0.00E+00 RU-106 7.45E+08 0.00E+00 9.30E+07 0.00E+00 1.01E+09 0.00E+00 1.16E+10 0.00E+00 RH-105 1.39E+05 7.45E+04 6.37E+04 0.00E+00 2.97E+05 0.00E+00 4.62E+06 0.00E+00 PD-107 0.00E+00 3.47E+07 2.95E+06 0.00E+00 2.90E+08 0.00E+00 6.89E+07 0.00E+00 PD-109 0.00E+00 2.88E+04 8.62E+03 0.00E+00 1.54E+05 0.00E+00 1.70E+06 0.00E+00 AG-110m 3.21E+07 2.17E+07 1.73E+07 0.00E+00 4.04E+07 0.00E+00 2.58E+09 0.00E+00 AG-111 3.79E+05 1.19E+05 7.83E+04 0.00E+00 3.58E+05 0.00E+00 7.26E+07 0.00E+00 CD-113m 0.00E+00 7.42E+08 3.16E+07 0.00E+00 7.64E+08 0.00E+00 1.91E+09 0.00E+00 CD-115m 0.00E+00 1.42E+08 6.04E+06 0.00E+00 1.05E+08 0.00E+00 1.93E+09 0.00E+00 SN-123 6.54E+09 8.12E+07 1.59E+08 8.61E+07 0.00E+00 0.00E+00 3.21E+09 0.00E+00 SN-125 7.45E+07 1.12E+06 3.34E+06 1.17E+06 0.00E+00 0.00E+00 2.31E+08 0.00E+00 SN-126 2.45E+10 3.05E+08 6.95E+08 8.38E+07 0.00E+00 0.00E+00 1.84E+09 0.00E+00 SB-124 3.52E+08 4.56E+06 1.23E+08 7.77E+05 0.00E+00 1.95E+08 2.20E+09 0.00E+00 SB-125 5.00E+08 3.85E+06 1.05E+08 4.63E+05 0.00E+00 2.78E+08 1.19E+09 0.00E+00 SB-126 1.39E+07 2.12E+05 4.98E+06 8.13E+04 0.00E+00 6.62E+06 2.79E+08 0.00E+00 SB-127 8.67E+05 1.34E+04 3.01E+05 9.65E+03 0.00E+00 3.76E+05 4.88E+07 0.00E+00 TE-125m 3.51E+08 9.50E+07 4.67E+07 9.84E+07 0.00E+00 0.00E+00 3.38E+08 0.00E+00 TE-127m 1.32E+09 3.56E+08 1.57E+08 3.16E+08 3.77E+09 0.00E+00 1.07E+09 0.00E+00 TE-127 9.76E+03 2.63E+03 2.09E+03 6.76E+03 2.78E+04 0.00E+00 3.81E+05 0.00E+00 TE-129m 8.41E+08 2.35E+08 1.31E+08 2.71E+08 2.47E+09 0.00E+00 1.03E+09 0.00E+00 TE-129 1.24E-03 3.45E-04 2.94E-04 8.82E-04 3.62E-03 0.00E+00 7.70E-02 0.00E+00 TE-133m 3.48E-05 1.41E-05 1.74E-05 2.70E-05 1.34E-04 0.00E+00 1.07E-03 0.00E+00 II.4-140 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-34 (Page 3 of 4)
Child Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 5.16E-08 2.32E-08 3.10E-08 4.08E-08 2.15E-07 0.00E+00 2.36E-07 0.00E+00 I-129 5.11E+09 3.14E+09 2.80E+09 2.05E+12 5.29E+09 0.00E+00 1.58E+08 0.00E+00 I-130 6.12E+05 1.24E+06 6.37E+05 1.36E+08 1.85E+06 0.00E+00 5.78E+05 0.00E+00 I-131 1.43E+08 1.44E+08 8.17E+07 4.75E+10 2.36E+08 0.00E+00 1.28E+07 0.00E+00 TE-131m 1.54E+06 5.32E+05 5.66E+05 1.09E+06 5.15E+06 0.00E+00 2.16E+07 0.00E+00 TE-131 2.14E-15 6.51E-16 6.35E-16 1.63E-15 6.46E-15 0.00E+00 1.12E-14 0.00E+00 I-132 8.91E+01 1.64E+02 7.53E+01 7.60E+03 2.51E+02 0.00E+00 1.93E+02 0.00E+00 TE-132 6.99E+06 3.10E+06 3.74E+06 4.51E+06 2.87E+07 0.00E+00 3.12E+07 0.00E+00 I-133 3.52E+06 4.35E+06 1.65E+06 8.08E+08 7.25E+06 0.00E+00 1.75E+06 0.00E+00 CS-134m 1.06E+01 1.57E+01 1.02E+01 0.00E+00 8.26E+00 1.37E+00 1.98E+01 0.00E+00 CS-134 1.60E+10 2.63E+10 5.55E+09 0.00E+00 8.15E+09 2.93E+09 1.42E+08 0.00E+00 I-134 1.42E-04 2.64E-04 1.21E-04 6.07E-03 4.03E-04 0.00E+00 1.75E-04 0.00E+00 I-135 6.18E+04 1.11E+05 5.26E+04 9.86E+06 1.71E+05 0.00E+00 8.48E+04 0.00E+00 CS-135 6.10E+09 4.25E+09 4.36E+08 0.00E+00 1.50E+09 5.01E+08 3.18E+07 0.00E+00 CS-136 8.24E+07 2.27E+08 1.47E+08 0.00E+00 1.21E+08 1.80E+07 7.96E+06 0.00E+00 CS-137 2.39E+10 2.29E+10 3.38E+09 0.00E+00 7.46E+09 2.68E+09 1.43E+08 0.00E+00 CS-138 5.69E-11 7.91E-11 5.02E-11 0.00E+00 5.57E-11 5.99E-12 3.64E-11 0.00E+00 CS-139 2.35E-44 2.61E-44 1.26E-44 0.00E+00 1.96E-44 1.98E-45 2.35E-48 0.00E+00 BA-139 4.69E-02 2.50E-05 1.36E-03 0.00E+00 2.18E-05 1.47E-05 2.70E+00 0.00E+00 BA-140 2.77E+08 2.42E+05 1.61E+07 0.00E+00 7.89E+04 1.44E+05 1.40E+08 0.00E+00 LA-140 3.24E+03 1.13E+03 3.82E+02 0.00E+00 0.00E+00 0.00E+00 3.16E+07 0.00E+00 BA-141 1.54E-21 8.64E-25 5.02E-23 0.00E+00 7.47E-25 5.07E-24 8.79E-22 0.00E+00 LA-141 1.05E+00 2.44E-01 5.31E-02 0.00E+00 0.00E+00 0.00E+00 5.44E+04 0.00E+00 CE-141 6.56E+05 3.27E+05 4.86E+04 0.00E+00 1.43E+05 0.00E+00 4.08E+08 0.00E+00 BA-142 6.46E-39 4.65E-42 3.61E-40 0.00E+00 3.76E-42 2.74E-42 8.43E-41 0.00E+00 LA-142 3.20E-04 1.02E-04 3.19E-05 0.00E+00 0.00E+00 0.00E+00 2.02E+01 0.00E+00 CE-143 1.71E+03 9.29E+05 1.35E+02 0.00E+00 3.90E+02 0.00E+00 1.36E+07 0.00E+00 PR-143 1.46E+05 4.37E+04 7.22E+03 0.00E+00 2.37E+04 0.00E+00 1.57E+08 0.00E+00 CE-144 1.27E+08 3.98E+07 6.78E+06 0.00E+00 2.21E+07 0.00E+00 1.04E+10 0.00E+00 PR-144 4.11E-26 1.27E-26 2.07E-27 0.00E+00 6.73E-27 0.00E+00 2.74E-23 0.00E+00 ND-147 7.15E+04 5.79E+04 4.48E+03 0.00E+00 3.18E+04 0.00E+00 9.17E+07 0.00E+00 PM-147 2.21E+07 1.58E+06 8.49E+05 0.00E+00 2.79E+06 0.00E+00 6.39E+08 0.00E+00 PM-148m 2.28E+06 4.54E+05 4.54E+05 0.00E+00 6.74E+05 0.00E+00 1.28E+09 0.00E+00 PM-148 3.36E+04 4.04E+03 2.62E+03 0.00E+00 6.87E+03 0.00E+00 1.08E+08 0.00E+00 PM-149 2.94E+03 3.12E+02 1.69E+02 0.00E+00 5.52E+02 0.00E+00 2.13E+07 0.00E+00 PM-151 5.75E+02 6.99E+01 4.55E+01 0.00E+00 1.19E+02 0.00E+00 7.93E+06 0.00E+00 SM-151 1.88E+07 2.80E+06 8.81E+05 0.00E+00 2.89E+06 0.00E+00 4.06E+08 0.00E+00 II.4-141 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-34 (Page 4 of 4)
Child Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.42E+03 8.80E+02 8.49E+01 0.00E+00 2.68E+02 0.00E+00 1.17E+07 0.00E+00 EU-152 4.47E+07 8.15E+06 9.67E+06 0.00E+00 3.44E+07 0.00E+00 1.34E+09 0.00E+00 EU-154 1.66E+08 1.50E+07 1.37E+07 0.00E+00 6.57E+07 0.00E+00 3.48E+09 0.00E+00 EU-155 3.44E+07 2.48E+06 1.94E+06 0.00E+00 9.28E+06 0.00E+00 6.20E+09 0.00E+00 EU-156 2.58E+05 1.38E+05 2.86E+04 0.00E+00 8.89E+04 0.00E+00 3.13E+08 0.00E+00 TB-160 6.02E+06 0.00E+00 7.47E+05 0.00E+00 1.79E+06 0.00E+00 1.34E+09 0.00E+00 HO-166m 7.94E+07 1.66E+07 1.40E+07 0.00E+00 2.37E+07 0.00E+00 7.35E-11 0.00E+00 W-181 2.03E+06 4.98E+05 6.85E+04 0.00E+00 0.00E+00 0.00E+00 1.81E+07 0.00E+00 W-185 6.44E+07 1.61E+07 2.25E+06 0.00E+00 0.00E+00 0.00E+00 5.99E+08 0.00E+00 W-187 6.41E+04 3.80E+04 1.70E+04 0.00E+00 0.00E+00 0.00E+00 5.34E+06 0.00E+00 NP-239 2.56E+03 1.84E+02 1.29E+02 0.00E+00 5.31E+02 0.00E+00 1.36E+07 0.00E+00 U-232 1.29E+12 0.00E+00 9.24E+10 0.00E+00 9.83E+10 0.00E+00 5.12E+09 0.00E+00 U-233 2.73E+11 0.00E+00 1.65E+10 0.00E+00 4.48E+10 0.00E+00 4.74E+09 0.00E+00 U-234 2.62E+11 0.00E+00 1.62E+10 0.00E+00 4.40E+10 0.00E+00 4.65E+09 0.00E+00 U-235 2.51E+11 0.00E+00 1.52E+10 0.00E+00 4.12E+10 0.00E+00 5.90E+09 0.00E+00 U-236 2.51E+11 0.00E+00 1.56E+10 0.00E+00 4.21E+10 0.00E+00 4.35E+09 0.00E+00 U-237 3.26E+05 0.00E+00 8.65E+04 0.00E+00 9.39E+05 0.00E+00 2.87E+07 0.00E+00 U-238 2.40E+11 0.00E+00 1.43E+10 0.00E+00 3.85E+10 0.00E+00 4.16E+09 0.00E+00 NP-237 1.64E+11 1.08E+10 7.20E+09 0.00E+00 4.45E+10 0.00E+00 6.00E+09 0.00E+00 NP-238 2.50E+04 5.07E+02 3.90E+02 0.00E+00 1.62E+03 0.00E+00 1.74E+07 0.00E+00 PU-238 8.73E+10 1.01E+10 2.32E+09 0.00E+00 8.44E+09 0.00E+00 5.50E+09 0.00E+00 PU-239 9.48E+10 1.01E+10 2.43E+09 0.00E+00 8.97E+09 0.00E+00 5.04E+09 0.00E+00 PU-240 9.41E+10 1.05E+10 2.43E+09 0.00E+00 8.97E+09 0.00E+00 5.13E+09 0.00E+00 PU-241 2.82E+09 1.15E+08 5.85E+07 0.00E+00 2.15E+08 0.00E+00 1.05E+08 0.00E+00 PU-242 8.75E+10 1.01E+10 2.34E+09 0.00E+00 8.60E+09 0.00E+00 4.93E+09 0.00E+00 PU-244 1.02E+11 1.16E+11 2.68E+09 0.00E+00 9.92E+09 0.00E+00 7.35E+09 0.00E+00 AM-241 9.99E+10 8.60E+10 7.50E+09 0.00E+00 4.58E+10 0.00E+00 5.61E+09 0.00E+00 AM-242m 1.03E+11 8.23E+10 7.64E+09 0.00E+00 4.63E+10 0.00E+00 7.06E+09 0.00E+00 AM-243 9.85E+10 8.31E+10 7.23E+09 0.00E+00 4.45E+10 0.00E+00 6.58E+09 0.00E+00 CM-242 4.69E+09 3.74E+09 3.12E+08 0.00E+00 9.99E+08 0.00E+00 4.36E+09 0.00E+00 CM-243 9.36E+10 7.61E+10 6.03E+09 0.00E+00 2.25E+10 0.00E+00 5.87E+09 0.00E+00 CM-244 7.88E+10 6.37E+10 5.05E+09 0.00E+00 1.85E+10 0.00E+00 5.67E+09 0.00E+00 CM-245 1.23E+11 9.85E+10 7.72E+09 0.00E+00 3.02E+10 0.00E+00 5.32E+09 0.00E+00 CM-246 1.21E+11 9.85E+10 7.72E+09 0.00E+00 3.01E+10 0.00E+00 5.23E+09 0.00E+00 CM-247 1.18E+11 9.70E+10 7.57E+09 0.00E+00 2.97E+10 0.00E+00 6.87E+09 0.00E+00 CM-248 9.85E+11 8.01E+11 6.26E+10 0.00E+00 2.45E+11 0.00E+00 1.11E+11 0.00E+00 CF-252 7.31E+10 0.00E+00 1.77E+09 0.00E+00 0.00E+00 0.00E+00 2.06E+10 0.00E+00 II.4-142 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-35 (Page 1 of 4)
Teen Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.47E+03 1.47E+03 1.47E+03 1.47E+03 1.47E+03 1.47E+03 0.00E+00 C-14 1.45E+06 2.91E+05 2.91E+05 2.91E+05 2.91E+05 2.91E+05 2.91E+05 0.00E+00 NA-22 2.01E+09 2.01E+09 2.01E+09 2.01E+09 2.01E+09 2.01E+09 2.01E+09 0.00E+00 NA-24 2.38E+05 2.38E+05 2.38E+05 2.38E+05 2.38E+05 2.38E+05 2.38E+05 0.00E+00 P-32 1.61E+09 9.97E+07 6.24E+07 0.00E+00 0.00E+00 0.00E+00 1.35E+08 0.00E+00 CA-41 1.79E+10 0.00E+00 1.94E+09 0.00E+00 0.00E+00 0.00E+00 1.77E+07 0.00E+00 SC-46 3.61E+05 7.03E+05 2.08E+05 0.00E+00 6.73E+05 0.00E+00 2.39E+09 0.00E+00 CR-51 0.00E+00 0.00E+00 6.17E+04 3.43E+04 1.35E+04 8.81E+04 1.04E+07 0.00E+00 MN-54 0.00E+00 4.54E+08 9.01E+07 0.00E+00 1.36E+08 0.00E+00 9.32E+08 0.00E+00 FE-55 3.26E+08 2.31E+08 5.39E+07 0.00E+00 0.00E+00 1.47E+08 1.00E+08 0.00E+00 MN-56 0.00E+00 1.39E+01 2.47E+00 0.00E+00 1.76E+01 0.00E+00 9.16E+02 0.00E+00 CO-57 0.00E+00 1.79E+07 3.00E+07 0.00E+00 0.00E+00 0.00E+00 3.33E+08 0.00E+00 CO-58 0.00E+00 4.36E+07 1.00E+08 0.00E+00 0.00E+00 0.00E+00 6.01E+08 0.00E+00 FE-59 1.79E+08 4.19E+08 1.62E+08 0.00E+00 0.00E+00 1.32E+08 9.90E+08 0.00E+00 CO-60 0.00E+00 2.49E+08 5.60E+08 0.00E+00 0.00E+00 0.00E+00 3.24E+09 0.00E+00 NI-59 1.20E+09 4.24E+08 2.04E+08 0.00E+00 0.00E+00 0.00E+00 6.64E+07 0.00E+00 NI-63 1.61E+10 1.13E+09 5.45E+08 0.00E+00 0.00E+00 0.00E+00 1.81E+08 0.00E+00 CU-64 0.00E+00 8.29E+03 3.90E+03 0.00E+00 2.10E+04 0.00E+00 6.43E+05 0.00E+00 NI-65 5.55E+01 7.09E+00 3.23E+00 0.00E+00 0.00E+00 0.00E+00 3.85E+02 0.00E+00 ZN-65 4.24E+08 1.47E+09 6.87E+08 0.00E+00 9.42E+08 0.00E+00 6.23E+08 0.00E+00 ZN-69m 2.06E+04 4.87E+04 4.46E+03 0.00E+00 2.96E+04 0.00E+00 2.68E+06 0.00E+00 ZN-69 4.73E-06 9.02E-06 6.31E-07 0.00E+00 5.89E-06 0.00E+00 1.66E-05 0.00E+00 SE-79 0.00E+00 3.39E+08 5.70E+07 0.00E+00 5.91E+08 0.00E+00 5.18E+07 0.00E+00 BR-82 0.00E+00 0.00E+00 1.32E+06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 2.82E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 1.95E-11 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.94E-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 2.74E+08 1.29E+08 0.00E+00 0.00E+00 0.00E+00 4.05E+07 0.00E+00 RB-87 0.00E+00 1.59E+09 5.55E+08 0.00E+00 0.00E+00 0.00E+00 5.55E+07 0.00E+00 RB-88 0.00E+00 2.44E-22 1.30E-22 0.00E+00 0.00E+00 0.00E+00 2.09E-29 0.00E+00 RB-89 0.00E+00 2.59E-26 1.83E-26 0.00E+00 0.00E+00 0.00E+00 3.98E-35 0.00E+00 SR-89 1.51E+10 0.00E+00 4.34E+08 0.00E+00 0.00E+00 0.00E+00 1.80E+09 0.00E+00 SR-90 9.22E+11 0.00E+00 1.84E+10 0.00E+00 0.00E+00 0.00E+00 2.11E+10 0.00E+00 Y-90 1.24E+04 0.00E+00 3.34E+02 0.00E+00 0.00E+00 0.00E+00 1.02E+08 0.00E+00 SR-91 2.82E+05 0.00E+00 1.12E+04 0.00E+00 0.00E+00 0.00E+00 1.28E+06 0.00E+00 Y-91m 4.43E-09 0.00E+00 1.69E-10 0.00E+00 0.00E+00 0.00E+00 2.09E-07 0.00E+00 Y-91 7.84E+06 0.00E+00 2.10E+05 0.00E+00 0.00E+00 0.00E+00 3.21E+09 0.00E+00 II.4-143 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-35 (Page 2 of 4)
Teen Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 3.86E+02 0.00E+00 1.65E+01 0.00E+00 0.00E+00 0.00E+00 9.83E+03 0.00E+00 Y-92 8.42E-01 0.00E+00 2.43E-02 0.00E+00 0.00E+00 0.00E+00 2.31E+04 0.00E+00 Y-93 1.58E+02 0.00E+00 4.33E+00 0.00E+00 0.00E+00 0.00E+00 4.82E+06 0.00E+00 NB-93m 3.10E+06 1.02E+06 2.55E+05 0.00E+00 1.19E+06 0.00E+00 3.66E+08 0.00E+00 NB-95 1.92E+05 1.07E+05 5.87E+04 0.00E+00 1.03E+05 0.00E+00 4.56E+08 0.00E+00 NB-97 1.87E-06 4.65E-07 1.70E-07 0.00E+00 5.43E-07 0.00E+00 1.11E-02 0.00E+00 ZR-93 5.03E+06 2.48E+06 1.35E+06 0.00E+00 8.77E+06 0.00E+00 2.34E+09 0.00E+00 ZR-95 1.72E+06 5.43E+05 3.73E+05 0.00E+00 7.98E+05 0.00E+00 1.25E+09 0.00E+00 ZR-97 3.11E+02 6.15E+01 2.83E+01 0.00E+00 9.33E+01 0.00E+00 1.67E+07 0.00E+00 MO-93 0.00E+00 9.63E+08 2.64E+07 0.00E+00 2.76E+08 0.00E+00 1.17E+08 0.00E+00 MO-99 0.00E+00 5.64E+06 1.08E+06 0.00E+00 1.29E+07 0.00E+00 1.01E+07 0.00E+00 TC-99 1.63E+07 2.39E+07 6.52E+06 0.00E+00 3.04E+08 2.47E+06 5.85E+08 0.00E+00 TC-99m 2.70E+00 7.54E+00 9.77E+01 0.00E+00 1.12E+02 4.18E+00 4.95E+03 0.00E+00 TC-101 5.52E-31 7.85E-31 7.71E-30 0.00E+00 1.42E-29 4.78E-31 1.34E-37 0.00E+00 RU-103 6.82E+06 0.00E+00 2.92E+06 0.00E+00 2.40E+07 0.00E+00 5.70E+08 0.00E+00 RU-105 4.92E+01 0.00E+00 1.91E+01 0.00E+00 6.20E+02 0.00E+00 3.97E+04 0.00E+00 RU-106 3.10E+08 0.00E+00 3.90E+07 0.00E+00 5.97E+08 0.00E+00 1.48E+10 0.00E+00 RH-105 7.54E+04 5.45E+04 3.58E+04 0.00E+00 2.32E+05 0.00E+00 6.93E+06 0.00E+00 PD-107 0.00E+00 1.89E+07 1.22E+06 0.00E+00 1.71E+08 0.00E+00 8.78E+07 0.00E+00 PD-109 0.00E+00 2.06E+04 4.67E+03 0.00E+00 1.19E+05 0.00E+00 2.07E+06 0.00E+00 AG-110m 1.52E+07 1.43E+07 8.72E+06 0.00E+00 2.74E+07 0.00E+00 4.03E+09 0.00E+00 AG-111 2.02E+05 8.37E+04 4.21E+04 0.00E+00 2.72E+05 0.00E+00 1.17E+08 0.00E+00 CD-113m 0.00E+00 4.06E+08 1.30E+07 0.00E+00 4.49E+08 0.00E+00 2.44E+09 0.00E+00 CD-115m 0.00E+00 7.94E+07 2.56E+06 0.00E+00 6.35E+07 0.00E+00 2.51E+09 0.00E+00 SN-123 2.72E+09 4.46E+07 6.61E+07 3.58E+07 0.00E+00 0.00E+00 4.11E+09 0.00E+00 SN-125 3.85E+07 7.68E+05 1.74E+06 6.02E+05 0.00E+00 0.00E+00 3.63E+08 0.00E+00 SN-126 1.05E+10 1.96E+08 3.00E+08 5.17E+07 0.00E+00 0.00E+00 2.34E+09 0.00E+00 SB-124 1.54E+08 2.84E+06 6.02E+07 3.50E+05 0.00E+00 1.35E+08 3.11E+09 0.00E+00 SB-125 2.14E+08 2.34E+06 5.01E+07 2.05E+05 0.00E+00 1.88E+08 1.67E+09 0.00E+00 SB-126 7.36E+06 1.50E+05 2.64E+06 4.16E+04 0.00E+00 5.28E+06 4.36E+08 0.00E+00 SB-127 4.79E+05 1.02E+04 1.81E+05 5.39E+03 0.00E+00 3.26E+05 8.14E+07 0.00E+00 TE-125m 1.48E+08 5.34E+07 1.98E+07 4.14E+07 0.00E+00 0.00E+00 4.37E+08 0.00E+00 TE-127m 5.51E+08 1.96E+08 6.56E+07 1.31E+08 2.24E+09 0.00E+00 1.37E+09 0.00E+00 TE-127 5.29E+03 1.88E+03 1.14E+03 3.65E+03 2.14E+04 0.00E+00 4.09E+05 0.00E+00 TE-129m 3.62E+08 1.34E+08 5.73E+07 1.17E+08 1.51E+09 0.00E+00 1.36E+09 0.00E+00 TE-129 6.68E-04 2.49E-04 1.63E-04 4.77E-04 2.80E-03 0.00E+00 3.65E-03 0.00E+00 TE-133m 1.94E-05 1.10E-05 1.07E-05 1.54E-05 1.09E-04 0.00E+00 4.45E-05 0.00E+00 II.4-144 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-35 (Page 3 of 4)
Teen Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 2.89E-08 1.85E-08 1.94E-08 2.37E-08 1.77E-07 0.00E+00 1.07E-09 0.00E+00 I-129 2.12E+09 1.78E+09 2.97E+09 2.17E+12 3.19E+09 0.00E+00 2.08E+08 0.00E+00 I-130 3.49E+05 1.01E+06 4.03E+05 8.22E+07 1.55E+06 0.00E+00 7.75E+05 0.00E+00 I-131 7.68E+07 1.08E+08 5.78E+07 3.14E+10 1.85E+08 0.00E+00 2.13E+07 0.00E+00 TE-131m 8.42E+05 4.04E+05 3.37E+05 6.07E+05 4.21E+06 0.00E+00 3.24E+07 0.00E+00 TE-131 1.16E-15 4.78E-16 3.62E-16 8.93E-16 5.07E-15 0.00E+00 9.52E-17 0.00E+00 I-132 5.02E+01 1.31E+02 4.72E+01 4.43E+03 2.07E+02 0.00E+00 5.72E+01 0.00E+00 TE-132 3.90E+06 2.47E+06 2.33E+06 2.61E+06 2.37E+07 0.00E+00 7.83E+07 0.00E+00 I-133 1.93E+06 3.27E+06 9.99E+05 4.57E+08 5.74E+06 0.00E+00 2.48E+06 0.00E+00 CS-134m 5.95E+00 1.23E+01 6.33E+00 0.00E+00 6.86E+00 1.20E+00 8.20E+00 0.00E+00 CS-134 7.10E+09 1.67E+10 7.75E+09 0.00E+00 5.31E+09 2.03E+09 2.08E+08 0.00E+00 I-134 7.99E-05 2.12E-04 7.61E-05 3.53E-03 3.34E-04 0.00E+00 2.79E-06 0.00E+00 I-135 3.48E+04 8.96E+04 3.32E+04 5.76E+06 1.42E+05 0.00E+00 9.93E+04 0.00E+00 CS-135 2.53E+09 2.32E+09 5.42E+08 0.00E+00 8.84E+08 3.20E+08 4.05E+07 0.00E+00 CS-136 4.37E+07 1.72E+08 1.16E+08 0.00E+00 9.37E+07 1.48E+07 1.38E+07 0.00E+00 CS-137 1.01E+10 1.35E+10 4.69E+09 0.00E+00 4.59E+09 1.78E+09 1.92E+08 0.00E+00 CS-138 3.13E-11 6.01E-11 3.00E-11 0.00E+00 4.44E-11 5.16E-12 2.73E-14 0.00E+00 CS-139 1.28E-44 1.88E-44 6.89E-45 0.00E+00 1.52E-44 1.66E-45 8.72E-60 0.00E+00 BA-139 2.54E-02 1.79E-05 7.40E-04 0.00E+00 1.69E-05 1.23E-05 2.27E-01 0.00E+00 BA-140 1.38E+08 1.69E+05 8.90E+06 0.00E+00 5.74E+04 1.14E+05 2.13E+08 0.00E+00 LA-140 1.80E+03 8.86E+02 2.36E+02 0.00E+00 0.00E+00 0.00E+00 5.09E+07 0.00E+00 BA-141 8.36E-22 6.24E-25 2.79E-23 0.00E+00 5.79E-25 4.27E-25 1.78E-27 0.00E+00 LA-141 5.67E-01 1.74E-01 2.88E-02 0.00E+00 0.00E+00 0.00E+00 3.09E+04 0.00E+00 CE-141 2.83E+05 1.89E+05 2.17E+04 0.00E+00 8.89E+04 0.00E+00 5.40E+08 0.00E+00 BA-142 3.57E-39 3.57E-42 2.20E-40 0.00E+00 3.02E-42 2.38E-42 1.10E-50 0.00E+00 LA-142 1.77E-04 7.84E-05 1.95E-05 0.00E+00 0.00E+00 0.00E+00 2.39E+00 0.00E+00 CE-143 9.30E+02 6.77E+05 7.56E+01 0.00E+00 3.04E+02 0.00E+00 2.04E+07 0.00E+00 PR-143 7.00E+04 2.80E+04 3.49E+03 0.00E+00 1.62E+04 0.00E+00 2.30E+08 0.00E+00 CE-144 5.27E+07 2.18E+07 2.83E+06 0.00E+00 1.30E+07 0.00E+00 1.33E+10 0.00E+00 PR-144 2.22E-26 9.07E-27 1.12E-27 0.00E+00 5.20E-27 0.00E+00 2.44E-29 0.00E+00 ND-147 3.62E+04 3.94E+04 2.36E+03 0.00E+00 2.31E+04 0.00E+00 1.42E+08 0.00E+00 PM-147 9.04E+06 8.57E+05 3.49E+05 0.00E+00 1.64E+06 0.00E+00 8.15E+08 0.00E+00 PM-148m 1.17E+06 2.96E+05 2.32E+05 0.00E+00 4.48E+05 0.00E+00 1.86E+09 0.00E+00 PM-148 1.83E+04 2.98E+03 1.50E+03 0.00E+00 5.39E+03 0.00E+00 1.78E+08 0.00E+00 PM-149 1.59E+03 2.23E+02 9.14E+01 0.00E+00 4.25E+02 0.00E+00 3.28E+07 0.00E+00 PM-151 3.14E+02 5.18E+01 2.62E+01 0.00E+00 9.32E+01 0.00E+00 1.16E+07 0.00E+00 SM-151 7.92E+06 1.52E+06 3.58E+05 0.00E+00 1.67E+06 0.00E+00 5.17E+08 0.00E+00 II.4-145 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-35 (Page 4 of 4)
Teen Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 7.64E+02 6.33E+02 4.65E+01 0.00E+00 2.07E+02 0.00E+00 1.79E+07 0.00E+00 EU-152 2.20E+07 5.31E+06 4.68E+06 0.00E+00 2.46E+07 0.00E+00 1.95E+09 0.00E+00 EU-154 7.07E+07 9.12E+06 6.43E+06 0.00E+00 4.08E+07 0.00E+00 4.82E+09 0.00E+00 EU-155 1.54E+07 1.48E+06 9.18E+05 0.00E+00 5.80E+06 0.00E+00 8.50E+09 0.00E+00 EU-156 1.24E+05 9.31E+04 1.52E+04 0.00E+00 6.26E+04 0.00E+00 4.76E+08 0.00E+00 TB-160 2.94E+06 0.00E+00 3.67E+05 0.00E+00 1.16E+06 0.00E+00 1.91E+09 0.00E+00 HO-166m 3.24E+07 1.00E+07 7.23E+06 0.00E+00 1.46E+07 0.00E+00 9.09E-11 0.00E+00 W-181 8.47E+05 2.73E+05 2.86E+04 0.00E+00 0.00E+00 0.00E+00 2.33E+07 0.00E+00 W-185 2.70E+07 8.90E+06 9.42E+05 0.00E+00 0.00E+00 0.00E+00 7.69E+08 0.00E+00 W-187 3.53E+04 2.87E+04 1.01E+04 0.00E+00 0.00E+00 0.00E+00 7.78E+06 0.00E+00 NP-239 1.38E+03 1.31E+02 7.25E+01 0.00E+00 4.10E+02 0.00E+00 2.10E+07 0.00E+00 U-232 5.34E+11 0.00E+00 3.82E+10 0.00E+00 5.79E+10 0.00E+00 6.52E+09 0.00E+00 U-233 1.13E+11 0.00E+00 6.85E+09 0.00E+00 2.64E+10 0.00E+00 6.04E+09 0.00E+00 U-234 1.08E+11 0.00E+00 6.72E+09 0.00E+00 2.59E+10 0.00E+00 5.92E+09 0.00E+00 U-235 1.04E+11 0.00E+00 6.31E+09 0.00E+00 2.43E+10 0.00E+00 7.53E+09 0.00E+00 U-236 1.04E+11 0.00E+00 6.44E+09 0.00E+00 2.48E+10 0.00E+00 5.55E+09 0.00E+00 U-237 1.74E+05 0.00E+00 4.64E+04 0.00E+00 7.16E+05 0.00E+00 4.62E+07 0.00E+00 U-238 9.91E+10 0.00E+00 5.90E+09 0.00E+00 2.27E+10 0.00E+00 5.30E+09 0.00E+00 NP-237 1.21E+11 8.68E+09 5.32E+09 0.00E+00 3.94E+10 0.00E+00 7.64E+09 0.00E+00 NP-238 1.35E+04 3.62E+02 2.11E+02 0.00E+00 1.24E+03 0.00E+00 2.66E+07 0.00E+00 PU-238 6.08E+10 7.79E+09 1.65E+09 0.00E+00 7.08E+09 0.00E+00 7.01E+09 0.00E+00 PU-239 6.95E+10 8.44E+09 1.83E+09 0.00E+00 7.79E+09 0.00E+00 6.42E+09 0.00E+00 PU-240 6.94E+10 8.43E+09 1.83E+09 0.00E+00 7.78E+09 0.00E+00 6.53E+09 0.00E+00 PU-241 1.57E+09 7.56E+07 3.32E+07 0.00E+00 1.54E+08 0.00E+00 1.33E+08 0.00E+00 PU-242 6.44E+10 8.13E+09 1.76E+09 0.00E+00 7.50E+09 0.00E+00 6.29E+09 0.00E+00 PU-244 7.53E+10 9.27E+09 2.02E+09 0.00E+00 8.59E+09 0.00E+00 9.36E+09 0.00E+00 AM-241 7.25E+10 6.84E+10 5.22E+09 0.00E+00 3.92E+10 0.00E+00 7.15E+09 0.00E+00 AM-242m 7.33E+10 6.46E+10 5.27E+09 0.00E+00 3.90E+10 0.00E+00 8.99E+09 0.00E+00 AM-243 7.23E+10 6.68E+10 5.11E+09 0.00E+00 3.84E+10 0.00E+00 8.39E+09 0.00E+00 CM-242 1.95E+09 2.06E+09 1.29E+08 0.00E+00 5.90E+08 0.00E+00 5.58E+09 0.00E+00 CM-243 5.88E+10 5.45E+10 3.70E+09 0.00E+00 1.73E+10 0.00E+00 7.49E+09 0.00E+00 CM-244 4.54E+10 4.30E+10 2.88E+09 0.00E+00 1.34E+10 0.00E+00 7.21E+09 0.00E+00 CM-245 9.00E+10 7.92E+10 5.54E+09 0.00E+00 2.59E+10 0.00E+00 6.78E+09 0.00E+00 CM-246 8.93E+10 7.91E+10 5.54E+09 0.00E+00 2.58E+10 0.00E+00 6.66E+09 0.00E+00 CM-247 8.70E+10 7.79E+10 5.45E+09 0.00E+00 2.54E+10 0.00E+00 8.75E+09 0.00E+00 CM-248 7.23E+11 6.42E+11 4.50E+10 0.00E+00 2.10E+11 0.00E+00 1.41E+11 0.00E+00 CF-252 2.99E+10 0.00E+00 7.21E+08 0.00E+00 0.00E+00 0.00E+00 2.63E+10 0.00E+00 II.4-146 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-36 (Page 1 of 4)
Adult Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.29E+03 1.29E+03 1.29E+03 1.29E+03 1.29E+03 1.29E+03 0.00E+00 C-14 8.97E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 0.00E+00 NA-22 1.32E+09 1.32E+09 1.32E+09 1.32E+09 1.32E+09 1.32E+09 1.32E+09 0.00E+00 NA-24 2.68E+05 2.68E+05 2.68E+05 2.68E+05 2.68E+05 2.68E+05 2.68E+05 0.00E+00 P-32 1.40E+09 8.73E+07 5.43E+07 0.00E+00 0.00E+00 0.00E+00 1.58E+08 0.00E+00 CA-41 1.48E+10 0.00E+00 1.60E+09 0.00E+00 0.00E+00 0.00E+00 1.47E+07 0.00E+00 SC-46 2.51E+05 4.87E+05 1.41E+05 0.00E+00 4.54E+05 0.00E+00 2.37E+09 0.00E+00 CR-51 0.00E+00 0.00E+00 4.64E+04 2.78E+04 1.02E+04 6.16E+04 1.17E+07 0.00E+00 MN-54 0.00E+00 3.13E+08 5.97E+07 0.00E+00 9.31E+07 0.00E+00 9.59E+08 0.00E+00 FE-55 2.10E+08 1.45E+08 3.38E+07 0.00E+00 0.00E+00 8.08E+07 8.31E+07 0.00E+00 MN-56 0.00E+00 1.54E+01 2.74E+00 0.00E+00 1.96E+01 0.00E+00 4.93E+02 0.00E+00 CO-57 0.00E+00 1.17E+07 1.95E+07 0.00E+00 0.00E+00 0.00E+00 2.97E+08 0.00E+00 CO-58 0.00E+00 3.07E+07 6.89E+07 0.00E+00 0.00E+00 0.00E+00 6.23E+08 0.00E+00 FE-59 1.26E+08 2.96E+08 1.14E+08 0.00E+00 0.00E+00 8.28E+07 9.88E+08 0.00E+00 CO-60 0.00E+00 1.67E+08 3.69E+08 0.00E+00 0.00E+00 0.00E+00 3.14E+09 0.00E+00 NI-59 7.82E+08 2.68E+08 1.31E+08 0.00E+00 0.00E+00 0.00E+00 5.53E+07 0.00E+00 NI-63 1.04E+10 7.21E+08 3.49E+08 0.00E+00 0.00E+00 0.00E+00 1.50E+08 0.00E+00 CU-64 0.00E+00 9.15E+03 4.29E+03 0.00E+00 2.31E+04 0.00E+00 7.79E+05 0.00E+00 NI-65 5.96E+01 7.75E+00 3.54E+00 0.00E+00 0.00E+00 0.00E+00 1.97E+02 0.00E+00 ZN-65 3.17E+08 1.01E+09 4.56E+08 0.00E+00 6.75E+08 0.00E+00 6.36E+08 0.00E+00 ZN-69m 2.23E+04 5.35E+04 4.89E+03 0.00E+00 3.24E+04 0.00E+00 3.26E+06 0.00E+00 ZN-69 5.06E-06 9.67E-06 6.72E-07 0.00E+00 6.28E-06 0.00E+00 1.45E-06 0.00E+00 SE-79 0.00E+00 2.11E+08 3.52E+07 0.00E+00 3.65E+08 0.00E+00 4.31E+07 0.00E+00 BR-82 0.00E+00 0.00E+00 1.50E+06 0.00E+00 0.00E+00 0.00E+00 1.72E+06 0.00E+00 BR-83 0.00E+00 0.00E+00 3.01E+00 0.00E+00 0.00E+00 0.00E+00 4.33E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 2.14E-11 0.00E+00 0.00E+00 0.00E+00 1.68E-16 0.00E+00 BR-85 0.00E+00 0.00E+00 2.07E-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 2.19E+08 1.02E+08 0.00E+00 0.00E+00 0.00E+00 4.33E+07 0.00E+00 RB-87 0.00E+00 9.86E+08 3.43E+08 0.00E+00 0.00E+00 0.00E+00 4.62E+07 0.00E+00 RB-88 0.00E+00 2.64E-22 1.40E-22 0.00E+00 0.00E+00 0.00E+00 3.65E-33 0.00E+00 RB-89 0.00E+00 2.88E-26 2.03E-26 0.00E+00 0.00E+00 0.00E+00 1.67E-39 0.00E+00 SR-89 9.97E+09 0.00E+00 2.86E+08 0.00E+00 0.00E+00 0.00E+00 1.60E+09 0.00E+00 SR-90 6.95E+11 0.00E+00 1.40E+10 0.00E+00 0.00E+00 0.00E+00 1.75E+10 0.00E+00 Y-90 1.33E+04 0.00E+00 3.56E+02 0.00E+00 0.00E+00 0.00E+00 1.41E+08 0.00E+00 SR-91 3.02E+05 0.00E+00 1.22E+04 0.00E+00 0.00E+00 0.00E+00 1.44E+06 0.00E+00 Y-91m 4.76E-09 0.00E+00 1.84E-10 0.00E+00 0.00E+00 0.00E+00 1.40E-08 0.00E+00 Y-91 5.11E+06 0.00E+00 1.37E+05 0.00E+00 0.00E+00 0.00E+00 2.81E+09 0.00E+00 II.4-147 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-36 (Page 2 of 4)
Adult Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 4.15E+02 0.00E+00 1.79E+01 0.00E+00 0.00E+00 0.00E+00 8.21E+03 0.00E+00 Y-92 8.96E-01 0.00E+00 2.62E-02 0.00E+00 0.00E+00 0.00E+00 1.57E+04 0.00E+00 Y-93 1.68E+02 0.00E+00 4.65E+00 0.00E+00 0.00E+00 0.00E+00 5.34E+06 0.00E+00 NB-93m 2.02E+06 6.61E+05 1.63E+05 0.00E+00 7.60E+05 0.00E+00 3.05E+08 0.00E+00 NB-95 1.42E+05 7.92E+04 4.26E+04 0.00E+00 7.83E+04 0.00E+00 4.81E+08 0.00E+00 NB-97 2.02E-06 5.11E-07 1.87E-07 0.00E+00 5.96E-07 0.00E+00 1.88E-03 0.00E+00 ZR-93 3.35E+06 1.88E+05 8.74E+04 0.00E+00 7.11E+05 0.00E+00 1.95E+08 0.00E+00 ZR-95 1.17E+06 3.77E+05 2.55E+05 0.00E+00 5.91E+05 0.00E+00 1.19E+09 0.00E+00 ZR-97 3.36E+02 6.78E+01 3.10E+01 0.00E+00 1.02E+02 0.00E+00 2.10E+07 0.00E+00 MO-93 0.00E+00 6.02E+08 1.63E+07 0.00E+00 1.71E+08 0.00E+00 9.78E+07 0.00E+00 MO-99 0.00E+00 6.14E+06 1.17E+06 0.00E+00 1.39E+07 0.00E+00 1.42E+07 0.00E+00 TC-99 1.00E+07 1.49E+07 4.02E+06 0.00E+00 1.88E+08 1.27E+06 4.87E+08 0.00E+00 TC-99m 3.06E+00 8.66E+00 1.10E+02 0.00E+00 1.31E+02 4.24E+00 5.12E+03 0.00E+00 TC-101 5.93E-31 8.55E-31 8.39E-30 0.00E+00 1.54E-29 4.37E-31 2.57E-42 0.00E+00 RU-103 4.77E+06 0.00E+00 2.06E+06 0.00E+00 1.82E+07 0.00E+00 5.57E+08 0.00E+00 RU-105 5.29E+01 0.00E+00 2.09E+01 0.00E+00 6.84E+02 0.00E+00 3.24E+04 0.00E+00 RU-106 1.93E+08 0.00E+00 2.44E+07 0.00E+00 3.72E+08 0.00E+00 1.25E+10 0.00E+00 RH-105 8.04E+04 5.88E+04 3.87E+04 0.00E+00 2.50E+05 0.00E+00 9.37E+06 0.00E+00 PD-107 0.00E+00 1.18E+07 7.53E+05 0.00E+00 1.06E+08 0.00E+00 7.30E+07 0.00E+00 PD-109 0.00E+00 2.21E+04 4.98E+03 0.00E+00 1.26E+05 0.00E+00 2.45E+06 0.00E+00 AG-110m 1.05E+07 9.75E+06 5.79E+06 0.00E+00 1.92E+07 0.00E+00 3.98E+09 0.00E+00 AG-111 2.11E+05 8.82E+04 4.39E+04 0.00E+00 2.85E+05 0.00E+00 1.62E+08 0.00E+00 CD-113m 0.00E+00 2.52E+08 8.09E+06 0.00E+00 2.78E+08 0.00E+00 2.03E+09 0.00E+00 CD-115m 0.00E+00 5.34E+07 1.70E+06 0.00E+00 4.24E+07 0.00E+00 2.25E+09 0.00E+00 SN-123 1.71E+09 2.84E+07 4.18E+07 2.41E+07 0.00E+00 0.00E+00 3.49E+09 0.00E+00 SN-125 3.85E+07 7.75E+05 1.74E+06 6.42E+05 0.00E+00 0.00E+00 4.80E+08 0.00E+00 SN-126 6.77E+09 1.34E+08 1.92E+08 3.94E+07 0.00E+00 0.00E+00 1.95E+09 0.00E+00 SB-124 1.04E+08 1.96E+06 4.11E+07 2.51E+05 0.00E+00 8.07E+07 2.94E+09 0.00E+00 SB-125 1.37E+08 1.53E+06 3.25E+07 1.39E+05 0.00E+00 1.05E+08 1.50E+09 0.00E+00 SB-126 7.01E+06 1.43E+05 2.53E+06 4.29E+04 0.00E+00 4.30E+06 5.73E+08 0.00E+00 SB-127 5.19E+05 1.14E+04 1.99E+05 6.24E+03 0.00E+00 3.08E+05 1.19E+08 0.00E+00 TE-125m 9.66E+07 3.50E+07 1.29E+07 2.90E+07 3.93E+08 0.00E+00 3.86E+08 0.00E+00 TE-127m 3.49E+08 1.25E+08 4.26E+07 8.92E+07 1.42E+09 0.00E+00 1.17E+09 0.00E+00 TE-127 5.61E+03 2.02E+03 1.21E+03 4.16E+03 2.29E+04 0.00E+00 4.43E+05 0.00E+00 TE-129m 2.51E+08 9.38E+07 3.98E+07 8.63E+07 1.05E+09 0.00E+00 1.27E+09 0.00E+00 TE-129 7.13E-04 2.68E-04 1.74E-04 5.48E-04 3.00E-03 0.00E+00 5.38E-04 0.00E+00 TE-133m 2.12E-05 1.24E-05 1.19E-05 1.79E-05 1.22E-04 0.00E+00 4.24E-06 0.00E+00 II.4-148 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-36 (Page 3 of 4)
Adult Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 3.19E-08 2.09E-08 1.28E-08 2.79E-08 2.02E-07 0.00E+00 3.54E-11 0.00E+00 I-129 1.31E+09 1.13E+09 3.69E+09 2.90E+12 2.42E+09 0.00E+00 1.78E+08 0.00E+00 I-130 3.90E+05 1.15E+06 4.54E+05 9.75E+07 1.79E+06 0.00E+00 9.90E+05 0.00E+00 I-131 8.07E+07 1.15E+08 6.62E+07 3.78E+10 1.98E+08 0.00E+00 3.05E+07 0.00E+00 TE-131m 9.10E+05 4.45E+05 3.71E+05 7.05E+05 4.51E+06 0.00E+00 4.42E+07 0.00E+00 TE-131 1.25E-15 5.21E-16 3.94E-16 1.03E-15 5.47E-15 0.00E+00 1.77E-16 0.00E+00 I-132 5.57E+01 1.49E+02 5.21E+01 5.21E+03 2.37E+02 0.00E+00 2.80E+01 0.00E+00 TE-132 4.30E+06 2.78E+06 2.61E+06 3.07E+06 2.68E+07 0.00E+00 1.31E+08 0.00E+00 I-133 2.08E+06 3.61E+06 1.10E+06 5.31E+08 6.31E+06 0.00E+00 3.25E+06 0.00E+00 CS-134m 6.57E+00 1.38E+01 7.06E+00 0.00E+00 7.49E+00 1.18E+00 4.87E+00 0.00E+00 CS-134 4.67E+09 1.11E+10 9.08E+09 0.00E+00 3.59E+09 1.19E+09 1.94E+08 0.00E+00 I-134 8.84E-05 2.40E-04 8.59E-05 4.16E-03 3.82E-04 0.00E+00 2.09E-07 0.00E+00 I-135 3.85E+04 1.01E+05 3.72E+04 6.65E+06 1.62E+05 0.00E+00 1.14E+05 0.00E+00 CS-135 1.56E+09 1.44E+09 6.40E+08 0.00E+00 5.46E+08 1.63E+08 3.37E+07 0.00E+00 CS-136 4.27E+07 1.68E+08 1.21E+08 0.00E+00 9.37E+07 1.28E+07 1.91E+07 0.00E+00 CS-137 6.36E+09 8.70E+09 5.70E+09 0.00E+00 2.95E+09 9.81E+08 1.68E+08 0.00E+00 CS-138 3.39E-11 6.70E-11 3.32E-11 0.00E+00 4.92E-11 4.86E-12 2.86E-16 0.00E+00 CS-139 1.36E-44 2.03E-44 7.39E-45 0.00E+00 1.62E-44 1.48E-45 4.39E-67 0.00E+00 BA-139 2.70E-02 1.92E-05 7.91E-04 0.00E+00 1.80E-05 1.09E-05 4.79E-02 0.00E+00 BA-140 1.28E+08 1.61E+05 8.42E+06 0.00E+00 5.49E+04 9.24E+04 2.65E+08 0.00E+00 LA-140 1.97E+03 9.95E+02 2.63E+02 0.00E+00 0.00E+00 0.00E+00 7.30E+07 0.00E+00 BA-141 8.94E-22 6.76E-25 3.02E-23 0.00E+00 6.28E-25 3.83E-25 4.21E-31 0.00E+00 LA-141 6.06E-01 1.88E-01 3.08E-02 0.00E+00 0.00E+00 0.00E+00 2.24E+04 0.00E+00 CE-141 1.97E+05 1.33E+05 1.51E+04 0.00E+00 6.19E+04 0.00E+00 5.10E+08 0.00E+00 BA-142 3.88E-39 3.99E-42 2.44E-40 0.00E+00 3.37E-42 2.26E-42 5.46E-57 0.00E+00 LA-142 1.92E-04 8.75E-05 2.18E-05 0.00E+00 0.00E+00 0.00E+00 6.39E-01 0.00E+00 CE-143 9.95E+02 7.36E+05 8.14E+01 0.00E+00 3.24E+02 0.00E+00 2.75E+07 0.00E+00 PR-143 6.26E+04 2.51E+04 3.10E+03 0.00E+00 1.45E+04 0.00E+00 2.74E+08 0.00E+00 CE-144 3.29E+07 1.38E+07 1.77E+06 0.00E+00 8.16E+06 0.00E+00 1.11E+10 0.00E+00 PR-144 2.36E-26 9.81E-27 1.20E-27 0.00E+00 5.53E-27 0.00E+00 3.40E-33 0.00E+00 ND-147 3.33E+04 3.85E+04 2.30E+03 0.00E+00 2.25E+04 0.00E+00 1.85E+08 0.00E+00 PM-147 5.74E+06 5.39E+05 2.18E+05 0.00E+00 1.02E+06 0.00E+00 6.80E+08 0.00E+00 PM-148m 8.30E+05 2.15E+05 1.64E+05 0.00E+00 3.24E+05 0.00E+00 1.82E+09 0.00E+00 PM-148 1.96E+04 3.25E+03 1.64E+03 0.00E+00 6.14E+03 0.00E+00 2.55E+08 0.00E+00 PM-149 1.69E+03 2.39E+02 9.78E+01 0.00E+00 4.52E+02 0.00E+00 4.49E+07 0.00E+00 PM-151 3.38E+02 5.67E+01 2.86E+01 0.00E+00 1.01E+02 0.00E+00 1.56E+07 0.00E+00 SM-151 5.52E+06 9.52E+05 2.28E+05 0.00E+00 1.06E+06 0.00E+00 4.20E+08 0.00E+00 II.4-149 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-36 (Page 4 of 4)
Adult Vegetation Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 8.18E+02 6.82E+02 4.98E+01 0.00E+00 2.20E+02 0.00E+00 2.43E+07 0.00E+00 EU-152 1.55E+07 3.52E+06 3.09E+06 0.00E+00 2.18E+07 0.00E+00 2.03E+09 0.00E+00 EU-154 4.85E+07 5.97E+06 4.25E+06 0.00E+00 2.86E+07 0.00E+00 4.32E+09 0.00E+00 EU-155 6.71E+06 9.51E+05 6.14E+05 0.00E+00 4.39E+06 0.00E+00 7.48E+08 0.00E+00 EU-156 1.08E+05 8.35E+04 1.35E+04 0.00E+00 5.58E+04 0.00E+00 5.72E+08 0.00E+00 TB-160 1.96E+06 0.00E+00 2.45E+05 0.00E+00 8.11E+05 0.00E+00 1.07E+09 0.00E+00 HO-166m 2.16E+07 6.76E+06 5.13E+06 0.00E+00 1.01E+07 0.00E+00 8.01E-11 0.00E+00 W-181 5.33E+05 1.74E+05 1.86E+04 0.00E+00 0.00E+00 0.00E+00 1.98E+07 0.00E+00 W-185 1.73E+07 5.77E+06 6.07E+05 0.00E+00 0.00E+00 0.00E+00 6.67E+08 0.00E+00 W-187 3.79E+04 3.17E+04 1.11E+04 0.00E+00 0.00E+00 0.00E+00 1.04E+07 0.00E+00 NP-239 1.43E+03 1.40E+02 7.73E+01 0.00E+00 4.37E+02 0.00E+00 2.88E+07 0.00E+00 U-232 3.30E+11 0.00E+00 2.36E+10 0.00E+00 3.58E+10 0.00E+00 5.42E+09 0.00E+00 U-233 6.98E+10 0.00E+00 4.23E+09 0.00E+00 1.63E+10 0.00E+00 5.02E+09 0.00E+00 U-234 6.70E+10 0.00E+00 4.14E+09 0.00E+00 1.59E+10 0.00E+00 4.92E+09 0.00E+00 U-235 6.42E+10 0.00E+00 3.89E+09 0.00E+00 1.50E+10 0.00E+00 6.26E+09 0.00E+00 U-236 6.42E+10 0.00E+00 3.97E+09 0.00E+00 1.53E+10 0.00E+00 4.62E+09 0.00E+00 U-237 1.84E+05 0.00E+00 4.89E+04 0.00E+00 7.55E+05 0.00E+00 6.45E+07 0.00E+00 U-238 6.15E+10 0.00E+00 3.64E+09 0.00E+00 1.40E+10 0.00E+00 4.41E+09 0.00E+00 NP-237 1.01E+11 7.18E+09 4.44E+09 0.00E+00 3.30E+10 0.00E+00 6.36E+09 0.00E+00 NP-238 1.45E+04 3.90E+02 2.25E+02 0.00E+00 1.32E+03 0.00E+00 3.63E+07 0.00E+00 PU-238 5.04E+10 6.39E+09 1.37E+09 0.00E+00 5.86E+09 0.00E+00 5.84E+09 0.00E+00 PU-239 5.81E+10 6.98E+09 1.53E+09 0.00E+00 6.50E+09 0.00E+00 5.34E+09 0.00E+00 PU-240 5.80E+10 6.97E+09 1.53E+09 0.00E+00 6.49E+09 0.00E+00 5.43E+09 0.00E+00 PU-241 1.25E+09 5.91E+07 2.64E+07 0.00E+00 1.21E+08 0.00E+00 1.11E+08 0.00E+00 PU-242 5.39E+10 6.72E+09 1.47E+09 0.00E+00 6.26E+09 0.00E+00 5.23E+09 0.00E+00 PU-244 6.28E+10 7.70E+09 1.69E+09 0.00E+00 7.17E+09 0.00E+00 7.80E+09 0.00E+00 AM-241 6.05E+10 5.65E+10 4.33E+09 0.00E+00 3.26E+10 0.00E+00 5.94E+09 0.00E+00 AM-242m 6.09E+10 5.31E+10 4.35E+09 0.00E+00 3.24E+10 0.00E+00 7.48E+09 0.00E+00 AM-243 6.04E+10 5.53E+10 4.25E+09 0.00E+00 3.20E+10 0.00E+00 6.97E+09 0.00E+00 CM-242 1.23E+09 1.30E+09 8.15E+07 0.00E+00 3.70E+08 0.00E+00 4.71E+09 0.00E+00 CM-243 4.78E+10 4.38E+10 2.99E+09 0.00E+00 1.40E+10 0.00E+00 6.23E+09 0.00E+00 CM-244 3.63E+10 3.40E+10 2.28E+09 0.00E+00 1.07E+10 0.00E+00 6.01E+09 0.00E+00 CM-245 7.52E+10 6.55E+10 4.62E+09 0.00E+00 2.16E+10 0.00E+00 5.64E+09 0.00E+00 CM-246 7.45E+10 6.54E+10 4.61E+09 0.00E+00 2.15E+10 0.00E+00 5.54E+09 0.00E+00 CM-247 7.27E+10 6.44E+10 4.54E+09 0.00E+00 2.12E+10 0.00E+00 7.28E+09 0.00E+00 CM-248 6.04E+11 5.31E+11 3.74E+10 0.00E+00 1.75E+11 0.00E+00 1.18E+11 0.00E+00 CF-252 1.99E+10 0.00E+00 4.79E+08 0.00E+00 0.00E+00 0.00E+00 2.19E+10 0.00E+00 II.4-150 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-37 (Page 1 of 4)
Infant Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 1.36E+03 0.00E+00 C-14 3.23E+06 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 0.00E+00 NA-22 3.18E+10 3.18E+10 3.18E+10 3.18E+10 3.18E+10 3.18E+10 3.18E+10 0.00E+00 NA-24 1.54E+07 1.54E+07 1.54E+07 1.54E+07 1.54E+07 1.54E+07 1.54E+07 0.00E+00 P-32 1.60E+11 9.43E+09 6.21E+09 0.00E+00 0.00E+00 0.00E+00 2.17E+09 0.00E+00 CA-41 2.46E+10 0.00E+00 2.69E+09 0.00E+00 0.00E+00 0.00E+00 1.26E+07 0.00E+00 SC-46 1.30E+03 1.88E+03 5.86E+02 0.00E+00 1.23E+03 0.00E+00 1.22E+06 0.00E+00 CR-51 0.00E+00 0.00E+00 1.61E+05 1.05E+05 2.30E+04 2.05E+05 4.70E+06 0.00E+00 MN-54 0.00E+00 3.90E+07 8.84E+06 0.00E+00 8.64E+06 0.00E+00 1.43E+07 0.00E+00 FE-55 1.35E+08 8.73E+07 2.33E+07 0.00E+00 0.00E+00 4.27E+07 1.11E+07 0.00E+00 MN-56 0.00E+00 3.14E-02 5.42E-03 0.00E+00 2.70E-02 0.00E+00 2.85E+00 0.00E+00 CO-57 0.00E+00 8.95E+06 1.46E+07 0.00E+00 0.00E+00 0.00E+00 3.05E+07 0.00E+00 CO-58 0.00E+00 2.42E+07 6.05E+07 0.00E+00 0.00E+00 0.00E+00 6.04E+07 0.00E+00 FE-59 2.24E+08 3.92E+08 1.54E+08 0.00E+00 0.00E+00 1.16E+08 1.87E+08 0.00E+00 CO-60 0.00E+00 8.82E+07 2.08E+08 0.00E+00 0.00E+00 0.00E+00 2.10E+08 0.00E+00 NI-59 2.61E+09 7.99E+08 4.50E+08 0.00E+00 0.00E+00 0.00E+00 3.95E+07 0.00E+00 NI-63 3.49E+10 2.16E+09 1.21E+09 0.00E+00 0.00E+00 0.00E+00 1.07E+08 0.00E+00 CU-64 0.00E+00 1.86E+05 8.59E+04 0.00E+00 3.14E+05 0.00E+00 3.81E+06 0.00E+00 NI-65 3.50E+00 3.97E-01 1.80E-01 0.00E+00 0.00E+00 0.00E+00 3.02E+01 0.00E+00 ZN-65 5.55E+09 1.90E+10 8.78E+09 0.00E+00 9.23E+09 0.00E+00 1.61E+10 0.00E+00 ZN-69m 1.68E+06 3.43E+06 3.13E+05 0.00E+00 1.39E+06 0.00E+00 4.75E+07 0.00E+00 ZN-69 2.02E-11 3.63E-11 2.70E-12 0.00E+00 1.51E-11 0.00E+00 2.96E-09 0.00E+00 SE-79 0.00E+00 7.77E+09 1.44E+09 0.00E+00 9.00E+09 0.00E+00 2.07E+08 0.00E+00 BR-82 0.00E+00 0.00E+00 1.93E+08 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 9.34E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 1.26E-22 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 1.88E-300 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 2.23E+10 1.10E+10 0.00E+00 0.00E+00 0.00E+00 5.69E+08 0.00E+00 RB-87 0.00E+00 2.19E+10 8.69E+09 0.00E+00 0.00E+00 0.00E+00 1.48E+08 0.00E+00 RB-88 0.00E+00 1.87E-44 1.03E-44 0.00E+00 0.00E+00 0.00E+00 1.83E-44 0.00E+00 RB-89 0.00E+00 3.29E-52 2.26E-52 0.00E+00 0.00E+00 0.00E+00 1.12E-52 0.00E+00 SR-89 1.26E+10 0.00E+00 3.61E+08 0.00E+00 0.00E+00 0.00E+00 2.59E+08 0.00E+00 SR-90 1.86E+11 0.00E+00 3.77E+09 0.00E+00 0.00E+00 0.00E+00 1.52E+09 0.00E+00 Y-90 6.81E+02 0.00E+00 1.83E+01 0.00E+00 0.00E+00 0.00E+00 9.41E+05 0.00E+00 SR-91 2.72E+05 0.00E+00 9.83E+03 0.00E+00 0.00E+00 0.00E+00 3.21E+05 0.00E+00 Y-91m 5.67E-19 0.00E+00 1.93E-20 0.00E+00 0.00E+00 0.00E+00 1.89E-15 0.00E+00 Y-91 7.33E+04 0.00E+00 1.95E+03 0.00E+00 0.00E+00 0.00E+00 5.25E+06 0.00E+00 II.4-151 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-37 (Page 2 of 4)
Infant Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 4.64E+00 0.00E+00 1.72E-01 0.00E+00 0.00E+00 0.00E+00 5.00E+01 0.00E+00 Y-92 5.38E-04 0.00E+00 1.51E-05 0.00E+00 0.00E+00 0.00E+00 1.03E+01 0.00E+00 Y-93 2.16E+00 0.00E+00 5.87E-02 0.00E+00 0.00E+00 0.00E+00 1.70E+04 0.00E+00 NB-93m 2.52E+06 6.83E+05 2.13E+05 0.00E+00 6.67E+05 0.00E+00 8.16E+07 0.00E+00 NB-95 5.93E+05 2.44E+05 1.41E+05 0.00E+00 1.75E+05 0.00E+00 2.06E+08 0.00E+00 NB-97 3.08E-11 6.57E-12 2.37E-12 0.00E+00 5.13E-12 0.00E+00 2.07E-06 0.00E+00 ZR-93 7.94E+03 3.78E+03 2.28E+03 0.00E+00 1.11E+04 0.00E+00 9.83E+05 0.00E+00 ZR-95 6.80E+03 1.66E+03 1.18E+03 0.00E+00 1.79E+03 0.00E+00 8.26E+05 0.00E+00 ZR-97 4.06E+00 6.97E-01 3.18E-01 0.00E+00 7.03E-01 0.00E+00 4.45E+04 0.00E+00 MO-93 0.00E+00 3.49E+09 1.12E+08 0.00E+00 6.97E+08 0.00E+00 7.47E+07 0.00E+00 MO-99 0.00E+00 2.08E+08 4.06E+07 0.00E+00 3.11E+08 0.00E+00 6.85E+07 0.00E+00 TC-99 2.22E+08 3.00E+08 9.36E+07 0.00E+00 2.53E+09 2.92E+07 1.30E+09 0.00E+00 TC-99m 2.75E+01 5.67E+01 7.30E+02 0.00E+00 6.10E+02 2.96E+01 1.65E+04 0.00E+00 TC-101 2.47E-59 3.11E-59 3.07E-58 0.00E+00 3.69E-58 1.69E-59 5.28E-57 0.00E+00 RU-103 8.67E+03 0.00E+00 2.90E+03 0.00E+00 1.80E+04 0.00E+00 1.05E+05 0.00E+00 RU-105 8.05E-03 0.00E+00 2.71E-03 0.00E+00 5.92E-02 0.00E+00 3.20E+00 0.00E+00 RU-106 1.90E+05 0.00E+00 2.38E+04 0.00E+00 2.25E+05 0.00E+00 1.44E+06 0.00E+00 RH-105 3.33E+06 2.18E+06 1.46E+06 0.00E+00 6.05E+06 0.00E+00 5.41E+07 0.00E+00 PD-107 0.00E+00 9.79E+07 6.95E+06 0.00E+00 5.59E+08 0.00E+00 7.78E+07 0.00E+00 PD-109 0.00E+00 3.99E+05 9.64E+04 0.00E+00 1.47E+06 0.00E+00 9.80E+06 0.00E+00 AG-110m 3.86E+08 2.82E+08 1.86E+08 0.00E+00 4.03E+08 0.00E+00 1.46E+10 0.00E+00 AG-111 6.17E+07 2.40E+07 1.27E+07 0.00E+00 5.01E+07 0.00E+00 5.72E+09 0.00E+00 CD-113m 0.00E+00 1.74E+07 6.42E+05 0.00E+00 1.32E+07 0.00E+00 2.62E+07 0.00E+00 CD-115m 0.00E+00 1.03E+07 3.59E+05 0.00E+00 5.40E+06 0.00E+00 5.89E+07 0.00E+00 SN-123 4.57E+09 7.14E+07 1.19E+08 7.18E+07 0.00E+00 0.00E+00 1.21E+09 0.00E+00 SN-125 5.38E+08 1.00E+07 2.39E+07 9.88E+06 0.00E+00 0.00E+00 8.06E+08 0.00E+00 SN-126 1.14E+10 1.49E+08 3.70E+08 3.93E+07 0.00E+00 0.00E+00 5.18E+08 0.00E+00 SB-124 2.09E+08 3.08E+06 6.49E+07 5.56E+05 0.00E+00 1.31E+08 6.46E+08 0.00E+00 SB-125 1.50E+08 1.45E+06 3.08E+07 1.87E+05 0.00E+00 8.66E+07 1.99E+08 0.00E+00 SB-126 4.18E+07 8.19E+05 1.51E+07 3.21E+05 0.00E+00 2.63E+07 4.33E+08 0.00E+00 SB-127 4.14E+06 7.39E+04 1.28E+06 5.27E+04 0.00E+00 2.13E+06 1.10E+08 0.00E+00 TE-125m 1.51E+08 5.04E+07 2.04E+07 5.07E+07 0.00E+00 0.00E+00 7.18E+07 0.00E+00 TE-127m 4.21E+08 1.40E+08 5.10E+07 1.22E+08 1.04E+09 0.00E+00 1.70E+08 0.00E+00 TE-127 6.32E+03 2.12E+03 1.36E+03 5.14E+03 1.54E+04 0.00E+00 1.33E+05 0.00E+00 TE-129m 5.57E+08 1.91E+08 8.58E+07 2.14E+08 1.39E+09 0.00E+00 3.33E+08 0.00E+00 TE-129 2.72E-09 9.37E-10 6.35E-10 2.28E-09 6.77E-09 0.00E+00 2.17E-07 0.00E+00 TE-133m 1.90E-12 8.68E-13 8.29E-13 1.67E-12 5.92E-12 0.00E+00 9.36E-11 0.00E+00 II.4-152 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-37 (Page 3 of 4)
Infant Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 7.81E-18 3.92E-18 4.04E-18 6.99E-18 2.64E-17 0.00E+00 8.95E-17 0.00E+00 I-129 7.06E+09 5.23E+09 3.83E+09 3.36E+12 6.20E+09 0.00E+00 1.05E+08 0.00E+00 I-130 3.55E+06 7.81E+06 3.13E+06 8.75E+08 8.58E+06 0.00E+00 1.67E+06 0.00E+00 I-131 2.72E+09 3.20E+09 1.41E+09 1.05E+12 3.74E+09 0.00E+00 1.14E+08 0.00E+00 TE-131m 3.38E+06 1.36E+06 1.12E+06 2.75E+06 9.35E+06 0.00E+00 2.29E+07 0.00E+00 TE-131 3.43E-32 1.27E-32 9.62E-33 3.06E-32 8.76E-32 0.00E+00 1.38E-30 0.00E+00 I-132 1.43E+00 2.90E+00 1.03E+00 1.36E+02 3.24E+00 0.00E+00 2.35E+00 0.00E+00 TE-132 2.11E+07 1.04E+07 9.75E+06 1.54E+07 6.53E+07 0.00E+00 3.87E+07 0.00E+00 I-133 3.63E+07 5.28E+07 1.55E+07 9.60E+09 6.21E+07 0.00E+00 8.93E+06 0.00E+00 CS-134m 1.53E+00 2.54E+00 1.28E+00 0.00E+00 9.81E-01 2.26E-01 2.01E+00 0.00E+00 CS-134 3.65E+10 6.80E+10 6.87E+09 0.00E+00 1.75E+10 7.18E+09 1.85E+08 0.00E+00 I-134 1.76E-11 3.60E-11 1.28E-11 8.40E-10 4.03E-11 0.00E+00 3.73E-11 0.00E+00 I-135 1.12E+05 2.23E+05 8.14E+04 2.00E+07 2.49E+05 0.00E+00 8.08E+04 0.00E+00 CS-135 1.31E+10 1.19E+10 6.22E+08 0.00E+00 3.40E+09 1.29E+09 4.31E+07 0.00E+00 CS-136 1.98E+09 5.81E+09 2.17E+09 0.00E+00 2.32E+09 4.74E+08 8.82E+07 0.00E+00 CS-137 5.15E+10 6.02E+10 4.27E+09 0.00E+00 1.62E+10 6.55E+09 1.88E+08 0.00E+00 CS-138 8.39E-23 1.36E-22 6.61E-23 0.00E+00 6.80E-23 1.06E-23 2.18E-22 0.00E+00 CS-139 6.56E-89 8.97E-89 3.43E-89 0.00E+00 4.64E-89 6.98E-90 5.63E-90 0.00E+00 BA-139 4.27E-07 2.83E-10 1.24E-08 0.00E+00 1.70E-10 1.72E-10 2.71E-05 0.00E+00 BA-140 2.41E+08 2.41E+05 1.24E+07 0.00E+00 5.72E+04 1.48E+05 5.92E+07 0.00E+00 LA-140 4.05E+01 1.60E+01 4.11E+00 0.00E+00 0.00E+00 0.00E+00 1.88E+05 0.00E+00 BA-141 3.93E-45 2.69E-48 1.24E-46 0.00E+00 1.62E-48 1.64E-48 4.80E-44 0.00E+00 LA-141 2.93E-04 8.51E-05 1.48E-05 0.00E+00 0.00E+00 0.00E+00 9.76E+00 0.00E+00 CE-141 4.34E+04 2.64E+04 3.11E+03 0.00E+00 8.15E+03 0.00E+00 1.37E+07 0.00E+00 BA-142 2.44E-79 2.03E-82 1.20E-80 0.00E+00 1.17E-82 1.23E-82 1.01E-78 0.00E+00 LA-142 1.70E-10 6.24E-11 1.49E-11 0.00E+00 0.00E+00 0.00E+00 1.06E-05 0.00E+00 CE-143 3.97E+02 2.63E+05 3.00E+01 0.00E+00 7.67E+01 0.00E+00 1.54E+06 0.00E+00 PR-143 1.49E+03 5.55E+02 7.36E+01 0.00E+00 2.06E+02 0.00E+00 7.84E+05 0.00E+00 CE-144 2.33E+06 9.52E+05 1.30E+05 0.00E+00 3.85E+05 0.00E+00 1.33E+08 0.00E+00 PR-144 5.69E-53 2.20E-53 2.86E-54 0.00E+00 7.97E-54 0.00E+00 1.02E-48 0.00E+00 ND-147 8.81E+02 9.05E+02 5.55E+01 0.00E+00 3.49E+02 0.00E+00 5.74E+05 0.00E+00 PM-147 1.57E+04 1.32E+03 6.44E+02 0.00E+00 1.98E+03 0.00E+00 3.75E+05 0.00E+00 PM-148m 4.90E+03 1.24E+03 9.74E+02 0.00E+00 1.43E+03 0.00E+00 1.62E+06 0.00E+00 PM-148 5.57E+02 8.04E+01 4.05E+01 0.00E+00 9.60E+01 0.00E+00 8.58E+05 0.00E+00 PM-149 4.13E+01 5.42E+00 2.37E+00 0.00E+00 6.59E+00 0.00E+00 1.46E+05 0.00E+00 PM-151 6.13E+00 8.94E-01 4.52E-01 0.00E+00 1.06E+00 0.00E+00 4.14E+04 0.00E+00 SM-151 1.19E+04 2.74E+03 5.92E+02 0.00E+00 1.86E+03 0.00E+00 2.29E+05 0.00E+00 II.4-153 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-37 (Page 4 of 4)
Infant Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.90E+01 1.47E+01 1.13E+00 0.00E+00 3.07E+00 0.00E+00 7.67E+04 0.00E+00 EU-152 2.76E+04 7.34E+03 6.19E+03 0.00E+00 2.06E+04 0.00E+00 6.52E+05 0.00E+00 EU-154 1.08E+05 1.50E+04 9.01E+03 0.00E+00 4.07E+04 0.00E+00 1.88E+06 0.00E+00 EU-155 2.21E+04 2.55E+03 1.32E+03 0.00E+00 5.71E+03 0.00E+00 3.41E+06 0.00E+00 EU-156 2.23E+03 1.38E+03 2.19E+02 0.00E+00 6.37E+02 0.00E+00 1.30E+06 0.00E+00 TB-160 8.76E+03 0.00E+00 1.10E+03 0.00E+00 2.49E+03 0.00E+00 1.17E+06 0.00E+00 HO-166m 5.14E+04 1.11E+04 8.76E+03 0.00E+00 1.47E+04 0.00E+00 4.11E-14 0.00E+00 W-181 3.23E+05 9.91E+04 1.11E+04 0.00E+00 0.00E+00 0.00E+00 1.39E+06 0.00E+00 W-185 1.23E+07 3.85E+06 4.39E+05 0.00E+00 0.00E+00 0.00E+00 5.51E+07 0.00E+00 W-187 6.08E+04 4.23E+04 1.46E+04 0.00E+00 0.00E+00 0.00E+00 2.48E+06 0.00E+00 NP-239 3.65E+01 3.26E+00 1.84E+00 0.00E+00 6.51E+00 0.00E+00 9.43E+04 0.00E+00 U-232 9.95E+10 0.00E+00 8.88E+09 0.00E+00 9.74E+09 0.00E+00 2.89E+08 0.00E+00 U-233 2.09E+10 0.00E+00 1.59E+09 0.00E+00 4.44E+09 0.00E+00 2.68E+08 0.00E+00 U-234 2.01E+10 0.00E+00 1.56E+09 0.00E+00 4.36E+09 0.00E+00 2.62E+08 0.00E+00 U-235 1.92E+10 0.00E+00 1.46E+09 0.00E+00 4.08E+09 0.00E+00 3.33E+08 0.00E+00 U-236 1.92E+10 0.00E+00 1.50E+09 0.00E+00 4.15E+09 0.00E+00 2.46E+08 0.00E+00 U-237 5.39E+05 0.00E+00 1.44E+05 0.00E+00 1.34E+06 0.00E+00 2.30E+07 0.00E+00 U-238 1.84E+10 0.00E+00 1.37E+09 0.00E+00 3.82E+09 0.00E+00 2.35E+08 0.00E+00 NP-237 9.87E+07 6.54E+06 4.32E+06 0.00E+00 2.61E+07 0.00E+00 3.39E+06 0.00E+00 NP-238 3.48E+02 8.75E+00 5.39E+00 0.00E+00 1.91E+01 0.00E+00 1.17E+05 0.00E+00 PU-238 2.11E+07 2.47E+06 5.59E+05 0.00E+00 1.99E+06 0.00E+00 1.25E+06 0.00E+00 PU-239 2.27E+07 2.55E+06 5.82E+05 0.00E+00 2.11E+06 0.00E+00 1.14E+06 0.00E+00 PU-240 2.27E+07 2.55E+06 5.82E+05 0.00E+00 2.11E+06 0.00E+00 1.16E+06 0.00E+00 PU-241 6.97E+05 2.89E+04 1.45E+04 0.00E+00 5.20E+04 0.00E+00 2.38E+04 0.00E+00 PU-242 2.11E+07 2.45E+06 5.61E+05 0.00E+00 2.02E+06 0.00E+00 1.11E+06 0.00E+00 PU-244 2.45E+07 2.81E+06 6.43E+05 0.00E+00 2.32E+06 0.00E+00 1.66E+06 0.00E+00 AM-241 6.01E+07 5.22E+07 4.48E+06 0.00E+00 2.69E+07 0.00E+00 3.17E+06 0.00E+00 AM-242m 6.21E+07 5.02E+07 4.65E+06 0.00E+00 2.73E+07 0.00E+00 3.99E+06 0.00E+00 AM-243 5.92E+07 5.06E+07 4.36E+06 0.00E+00 2.62E+07 0.00E+00 3.71E+06 0.00E+00 CM-242 5.15E+06 4.77E+06 3.42E+05 0.00E+00 9.84E+05 0.00E+00 3.09E+06 0.00E+00 CM-243 5.75E+07 4.72E+07 3.69E+06 0.00E+00 1.34E+07 0.00E+00 3.33E+06 0.00E+00 CM-244 4.84E+07 3.98E+07 3.12E+06 0.00E+00 1.11E+07 0.00E+00 3.22E+06 0.00E+00 CM-245 7.36E+07 5.96E+07 4.65E+06 0.00E+00 1.78E+07 0.00E+00 3.00E+06 0.00E+00 CM-246 7.28E+07 5.96E+07 4.65E+06 0.00E+00 1.77E+07 0.00E+00 2.95E+06 0.00E+00 CM-247 7.12E+07 5.88E+07 4.57E+06 0.00E+00 1.74E+07 0.00E+00 3.88E+06 0.00E+00 CM-248 5.88E+08 4.85E+08 3.77E+07 0.00E+00 1.44E+08 0.00E+00 6.25E+07 0.00E+00 CF-252 4.94E+07 0.00E+00 1.19E+06 0.00E+00 0.00E+00 0.00E+00 1.21E+07 0.00E+00 II.4-154 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-38 (Page 1 of 4)
Child Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 8.97E+02 8.97E+02 8.97E+02 8.97E+02 8.97E+02 8.97E+02 0.00E+00 C-14 1.65E+06 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 0.00E+00 NA-22 1.90E+10 1.90E+10 1.90E+10 1.90E+10 1.90E+10 1.90E+10 1.90E+10 0.00E+00 NA-24 8.85E+06 8.85E+06 8.85E+06 8.85E+06 8.85E+06 8.85E+06 8.85E+06 0.00E+00 P-32 7.78E+10 3.64E+09 3.00E+09 0.00E+00 0.00E+00 0.00E+00 2.15E+09 0.00E+00 CA-41 2.28E+10 0.00E+00 2.49E+09 0.00E+00 0.00E+00 0.00E+00 1.25E+07 0.00E+00 SC-46 6.83E+02 9.36E+02 3.61E+02 0.00E+00 8.29E+02 0.00E+00 1.37E+06 0.00E+00 CR-51 0.00E+00 0.00E+00 1.02E+05 5.65E+04 1.54E+04 1.03E+05 5.40E+06 0.00E+00 MN-54 0.00E+00 2.10E+07 5.59E+06 0.00E+00 5.88E+06 0.00E+00 1.76E+07 0.00E+00 FE-55 1.12E+08 5.93E+07 1.84E+07 0.00E+00 0.00E+00 3.35E+07 1.10E+07 0.00E+00 MN-56 0.00E+00 1.28E-02 2.90E-03 0.00E+00 1.55E-02 0.00E+00 1.86E+00 0.00E+00 CO-57 0.00E+00 3.84E+06 7.77E+06 0.00E+00 0.00E+00 0.00E+00 3.14E+07 0.00E+00 CO-58 0.00E+00 1.21E+07 3.71E+07 0.00E+00 0.00E+00 0.00E+00 7.07E+07 0.00E+00 FE-59 1.20E+08 1.95E+08 9.69E+07 0.00E+00 0.00E+00 5.64E+07 2.03E+08 0.00E+00 CO-60 0.00E+00 4.32E+07 1.27E+08 0.00E+00 0.00E+00 0.00E+00 2.39E+08 0.00E+00 NI-59 2.22E+09 5.90E+08 3.76E+08 0.00E+00 0.00E+00 0.00E+00 3.91E+07 0.00E+00 NI-63 2.96E+10 1.59E+09 1.01E+09 0.00E+00 0.00E+00 0.00E+00 1.07E+08 0.00E+00 CU-64 0.00E+00 7.46E+04 4.51E+04 0.00E+00 1.80E+05 0.00E+00 3.50E+06 0.00E+00 NI-65 1.66E+00 1.56E-01 9.10E-02 0.00E+00 0.00E+00 0.00E+00 1.91E+01 0.00E+00 ZN-65 4.13E+09 1.10E+10 6.85E+09 0.00E+00 6.94E+09 0.00E+00 1.93E+09 0.00E+00 ZN-69m 7.96E+05 1.36E+06 1.60E+05 0.00E+00 7.88E+05 0.00E+00 4.41E+07 0.00E+00 ZN-69 9.47E-12 1.37E-11 1.26E-12 0.00E+00 8.30E-12 0.00E+00 8.62E-10 0.00E+00 SE-79 0.00E+00 3.12E+09 6.92E+08 0.00E+00 5.07E+09 0.00E+00 2.05E+08 0.00E+00 BR-82 0.00E+00 0.00E+00 1.15E+08 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 4.40E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 6.51E-23 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 8.85E-301 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 8.77E+09 5.39E+09 0.00E+00 0.00E+00 0.00E+00 5.64E+08 0.00E+00 RB-87 0.00E+00 9.75E+09 4.52E+09 0.00E+00 0.00E+00 0.00E+00 1.46E+08 0.00E+00 RB-88 0.00E+00 7.15E-45 4.97E-45 0.00E+00 0.00E+00 0.00E+00 3.51E-46 0.00E+00 RB-89 0.00E+00 1.34E-52 1.20E-52 0.00E+00 0.00E+00 0.00E+00 1.17E-54 0.00E+00 SR-89 6.62E+09 0.00E+00 1.89E+08 0.00E+00 0.00E+00 0.00E+00 2.56E+08 0.00E+00 SR-90 1.68E+11 0.00E+00 3.38E+09 0.00E+00 0.00E+00 0.00E+00 1.51E+09 0.00E+00 Y-90 3.22E+02 0.00E+00 8.62E+00 0.00E+00 0.00E+00 0.00E+00 9.17E+05 0.00E+00 SR-91 1.30E+05 0.00E+00 4.92E+03 0.00E+00 0.00E+00 0.00E+00 2.88E+05 0.00E+00 Y-91m 2.68E-19 0.00E+00 9.74E-21 0.00E+00 0.00E+00 0.00E+00 5.24E-16 0.00E+00 Y-91 3.90E+04 0.00E+00 1.04E+03 0.00E+00 0.00E+00 0.00E+00 5.20E+06 0.00E+00 II.4-155 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-38 (Page 2 of 4)
Child Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 2.18E+00 0.00E+00 8.75E-02 0.00E+00 0.00E+00 0.00E+00 4.13E+01 0.00E+00 Y-92 2.53E-04 0.00E+00 7.24E-06 0.00E+00 0.00E+00 0.00E+00 7.31E+00 0.00E+00 Y-93 1.01E+00 0.00E+00 2.78E-02 0.00E+00 0.00E+00 0.00E+00 1.51E+04 0.00E+00 NB-93m 2.15E+06 5.37E+05 1.77E+05 0.00E+00 5.80E+05 0.00E+00 8.10E+07 0.00E+00 NB-95 3.18E+05 1.24E+05 8.84E+04 0.00E+00 1.16E+05 0.00E+00 2.29E+08 0.00E+00 NB-97 1.46E-11 2.63E-12 1.23E-12 0.00E+00 2.92E-12 0.00E+00 8.12E-07 0.00E+00 ZR-93 6.87E+03 2.57E+03 1.83E+03 0.00E+00 9.96E+03 0.00E+00 9.75E+05 0.00E+00 ZR-95 3.83E+03 8.42E+02 7.50E+02 0.00E+00 1.21E+03 0.00E+00 8.79E+05 0.00E+00 ZR-97 1.92E+00 2.77E-01 1.64E-01 0.00E+00 3.98E-01 0.00E+00 4.20E+04 0.00E+00 MO-93 0.00E+00 1.49E+09 5.34E+07 0.00E+00 3.92E+08 0.00E+00 7.53E+07 0.00E+00 MO-99 0.00E+00 8.14E+07 2.01E+07 0.00E+00 1.74E+08 0.00E+00 6.73E+07 0.00E+00 TC-99 1.10E+08 1.23E+08 4.40E+07 0.00E+00 1.44E+09 1.08E+07 1.29E+09 0.00E+00 TC-99m 1.32E+01 2.59E+01 4.29E+02 0.00E+00 3.76E+02 1.32E+01 1.47E+04 0.00E+00 TC-101 1.16E-59 1.22E-59 1.54E-58 0.00E+00 2.08E-58 6.43E-60 3.87E-59 0.00E+00 RU-103 4.28E+03 0.00E+00 1.65E+03 0.00E+00 1.08E+04 0.00E+00 1.11E+05 0.00E+00 RU-105 3.82E-03 0.00E+00 1.39E-03 0.00E+00 3.36E-02 0.00E+00 2.49E+00 0.00E+00 RU-106 9.24E+04 0.00E+00 1.15E+04 0.00E+00 1.25E+05 0.00E+00 1.44E+06 0.00E+00 RH-105 1.57E+06 8.43E+05 7.21E+05 0.00E+00 3.36E+06 0.00E+00 5.22E+07 0.00E+00 PD-107 0.00E+00 3.88E+07 3.30E+06 0.00E+00 3.25E+08 0.00E+00 7.71E+07 0.00E+00 PD-109 0.00E+00 1.51E+05 4.53E+04 0.00E+00 8.10E+05 0.00E+00 8.92E+06 0.00E+00 AG-110m 2.09E+08 1.41E+08 1.13E+08 0.00E+00 2.63E+08 0.00E+00 1.68E+10 0.00E+00 AG-111 2.94E+07 9.21E+06 6.08E+06 0.00E+00 2.78E+07 0.00E+00 5.64E+09 0.00E+00 CD-113m 0.00E+00 1.00E+07 4.27E+05 0.00E+00 1.03E+07 0.00E+00 2.59E+07 0.00E+00 CD-115m 0.00E+00 4.29E+06 1.83E+05 0.00E+00 3.19E+06 0.00E+00 5.83E+07 0.00E+00 SN-123 2.44E+09 3.03E+07 5.95E+07 3.21E+07 0.00E+00 0.00E+00 1.20E+09 0.00E+00 SN-125 2.58E+08 3.89E+06 1.15E+07 4.03E+06 0.00E+00 0.00E+00 7.99E+08 0.00E+00 SN-126 6.85E+09 8.54E+07 1.95E+08 2.34E+07 0.00E+00 0.00E+00 5.14E+08 0.00E+00 SB-124 1.09E+08 1.41E+06 3.81E+07 2.40E+05 0.00E+00 6.03E+07 6.79E+08 0.00E+00 SB-125 8.70E+07 6.71E+05 1.82E+07 8.06E+04 0.00E+00 4.85E+07 2.08E+08 0.00E+00 SB-126 2.28E+07 3.49E+05 8.19E+06 1.34E+05 0.00E+00 1.09E+07 4.60E+08 0.00E+00 SB-127 1.97E+06 3.04E+04 6.83E+05 2.19E+04 0.00E+00 8.54E+05 1.11E+08 0.00E+00 TE-125m 7.38E+07 2.00E+07 9.84E+06 2.07E+07 0.00E+00 0.00E+00 7.12E+07 0.00E+00 TE-127m 2.08E+08 5.60E+07 2.47E+07 4.97E+07 5.93E+08 0.00E+00 1.68E+08 0.00E+00 TE-127 2.98E+03 8.02E+02 6.38E+02 2.06E+03 8.47E+03 0.00E+00 1.16E+05 0.00E+00 TE-129m 2.71E+08 7.58E+07 4.21E+07 8.75E+07 7.97E+08 0.00E+00 3.31E+08 0.00E+00 TE-129 1.28E-09 3.58E-10 3.04E-10 9.15E-10 3.75E-09 0.00E+00 7.98E-08 0.00E+00 TE-133m 9.07E-13 3.67E-13 4.54E-13 7.03E-13 3.48E-12 0.00E+00 2.80E-11 0.00E+00 II.4-156 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-38 (Page 3 of 4)
Child Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 3.77E-18 1.70E-18 2.26E-18 2.98E-18 1.57E-17 0.00E+00 1.72E-17 0.00E+00 I-129 3.43E+09 2.11E+09 1.88E+09 1.38E+12 3.55E+09 0.00E+00 1.06E+08 0.00E+00 I-130 1.73E+06 3.49E+06 1.80E+06 3.84E+08 5.22E+06 0.00E+00 1.63E+06 0.00E+00 I-131 1.30E+09 1.31E+09 7.45E+08 4.33E+11 2.15E+09 0.00E+00 1.17E+08 0.00E+00 TE-131m 1.60E+06 5.53E+05 5.89E+05 1.14E+06 5.35E+06 0.00E+00 2.24E+07 0.00E+00 TE-131 1.62E-32 4.93E-33 4.81E-33 1.24E-32 4.89E-32 0.00E+00 8.49E-32 0.00E+00 I-132 6.89E-01 1.27E+00 5.82E-01 5.87E+01 1.94E+00 0.00E+00 1.49E+00 0.00E+00 TE-132 1.02E+07 4.53E+06 5.48E+06 6.60E+06 4.21E+07 0.00E+00 4.57E+07 0.00E+00 I-133 1.72E+07 2.12E+07 8.03E+06 3.94E+09 3.54E+07 0.00E+00 8.56E+06 0.00E+00 CS-134m 7.32E-01 1.08E+00 7.08E-01 0.00E+00 5.72E-01 9.46E-02 1.37E+00 0.00E+00 CS-134 2.26E+10 3.72E+10 7.84E+09 0.00E+00 1.15E+10 4.13E+09 2.00E+08 0.00E+00 I-134 8.48E-12 1.58E-11 7.25E-12 3.62E-10 2.41E-11 0.00E+00 1.04E-11 0.00E+00 I-135 5.40E+04 9.72E+04 4.60E+04 8.61E+06 1.49E+05 0.00E+00 7.40E+04 0.00E+00 CS-135 8.19E+09 5.71E+09 5.85E+08 0.00E+00 2.01E+09 6.72E+08 4.27E+07 0.00E+00 CS-136 1.01E+09 2.78E+09 1.80E+09 0.00E+00 1.48E+09 2.21E+08 9.77E+07 0.00E+00 CS-137 3.22E+10 3.09E+10 4.55E+09 0.00E+00 1.01E+10 3.62E+09 1.93E+08 0.00E+00 CS-138 3.98E-23 5.53E-23 3.51E-23 0.00E+00 3.89E-23 4.19E-24 2.55E-23 0.00E+00 CS-139 3.07E-89 3.41E-89 1.64E-89 0.00E+00 2.56E-89 2.58E-90 3.07E-93 0.00E+00 BA-139 2.01E-07 1.07E-10 5.82E-09 0.00E+00 9.36E-11 6.30E-11 1.16E-05 0.00E+00 BA-140 1.17E+08 1.03E+05 6.84E+06 0.00E+00 3.34E+04 6.12E+04 5.93E+07 0.00E+00 LA-140 1.94E+01 6.78E+00 2.29E+00 0.00E+00 0.00E+00 0.00E+00 1.89E+05 0.00E+00 BA-141 1.85E-45 1.04E-48 6.02E-47 0.00E+00 8.96E-49 6.09E-48 1.05E-45 0.00E+00 LA-141 1.38E-04 3.22E-05 6.99E-06 0.00E+00 0.00E+00 0.00E+00 7.16E+00 0.00E+00 CE-141 2.19E+04 1.09E+04 1.62E+03 0.00E+00 4.78E+03 0.00E+00 1.36E+07 0.00E+00 BA-142 1.16E-79 8.35E-83 6.48E-81 0.00E+00 6.76E-83 4.91E-83 1.51E-81 0.00E+00 LA-142 8.10E-11 2.58E-11 8.08E-12 0.00E+00 0.00E+00 0.00E+00 5.11E-06 0.00E+00 CE-143 1.87E+02 1.02E+05 1.47E+01 0.00E+00 4.26E+01 0.00E+00 1.49E+06 0.00E+00 PR-143 7.18E+02 2.16E+02 3.56E+01 0.00E+00 1.17E+02 0.00E+00 7.75E+05 0.00E+00 CE-144 1.62E+06 5.09E+05 8.66E+04 0.00E+00 2.82E+05 0.00E+00 1.33E+08 0.00E+00 PR-144 2.68E-53 8.28E-54 1.35E-54 0.00E+00 4.38E-54 0.00E+00 1.78E-50 0.00E+00 ND-147 4.45E+02 3.60E+02 2.79E+01 0.00E+00 1.98E+02 0.00E+00 5.70E+05 0.00E+00 PM-147 1.29E+04 9.19E+02 4.94E+02 0.00E+00 1.62E+03 0.00E+00 3.72E+05 0.00E+00 PM-148m 3.06E+03 6.09E+02 6.09E+02 0.00E+00 9.03E+02 0.00E+00 1.72E+06 0.00E+00 PM-148 2.66E+02 3.20E+01 2.07E+01 0.00E+00 5.43E+01 0.00E+00 8.54E+05 0.00E+00 PM-149 1.94E+01 2.07E+00 1.12E+00 0.00E+00 3.66E+00 0.00E+00 1.41E+05 0.00E+00 PM-151 2.90E+00 3.52E-01 2.29E-01 0.00E+00 5.97E-01 0.00E+00 4.00E+04 0.00E+00 SM-151 1.05E+04 1.57E+03 4.93E+02 0.00E+00 1.62E+03 0.00E+00 2.27E+05 0.00E+00 II.4-157 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-38 (Page 4 of 4)
Child Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 8.98E+00 5.58E+00 5.39E-01 0.00E+00 1.70E+00 0.00E+00 7.43E+04 0.00E+00 EU-152 2.52E+04 4.59E+03 5.45E+03 0.00E+00 1.94E+04 0.00E+00 7.55E+05 0.00E+00 EU-154 9.42E+04 8.47E+03 7.74E+03 0.00E+00 3.72E+04 0.00E+00 1.97E+06 0.00E+00 EU-155 1.97E+04 1.42E+03 1.11E+03 0.00E+00 5.30E+03 0.00E+00 3.54E+06 0.00E+00 EU-156 1.10E+03 5.88E+02 1.22E+02 0.00E+00 3.79E+02 0.00E+00 1.33E+06 0.00E+00 TB-160 5.61E+03 0.00E+00 6.96E+02 0.00E+00 1.67E+03 0.00E+00 1.24E+06 0.00E+00 HO-166m 4.44E+04 9.30E+03 7.86E+03 0.00E+00 1.32E+04 0.00E+00 4.11E-14 0.00E+00 W-181 1.54E+05 3.79E+04 5.21E+03 0.00E+00 0.00E+00 0.00E+00 1.38E+06 0.00E+00 W-185 5.89E+06 1.47E+06 2.06E+05 0.00E+00 0.00E+00 0.00E+00 5.48E+07 0.00E+00 W-187 2.89E+04 1.71E+04 7.68E+03 0.00E+00 0.00E+00 0.00E+00 2.40E+06 0.00E+00 NP-239 1.72E+01 1.24E+00 8.71E-01 0.00E+00 3.58E+00 0.00E+00 9.17E+04 0.00E+00 U-232 7.24E+10 0.00E+00 5.18E+09 0.00E+00 5.51E+09 0.00E+00 2.87E+08 0.00E+00 U-233 1.53E+10 0.00E+00 9.26E+08 0.00E+00 2.51E+09 0.00E+00 2.65E+08 0.00E+00 U-234 1.47E+10 0.00E+00 9.09E+08 0.00E+00 2.46E+09 0.00E+00 2.60E+08 0.00E+00 U-235 1.41E+10 0.00E+00 8.52E+08 0.00E+00 2.31E+09 0.00E+00 3.30E+08 0.00E+00 U-236 1.41E+10 0.00E+00 8.72E+08 0.00E+00 2.36E+09 0.00E+00 2.44E+08 0.00E+00 U-237 2.57E+05 0.00E+00 6.83E+04 0.00E+00 7.42E+05 0.00E+00 2.27E+07 0.00E+00 U-238 1.35E+10 0.00E+00 7.98E+08 0.00E+00 2.16E+09 0.00E+00 2.33E+08 0.00E+00 NP-237 9.17E+07 6.05E+06 4.03E+06 0.00E+00 2.49E+07 0.00E+00 3.36E+06 0.00E+00 NP-238 1.64E+02 3.31E+00 2.55E+00 0.00E+00 1.05E+01 0.00E+00 1.13E+05 0.00E+00 PU-238 1.96E+07 2.27E+06 5.20E+05 0.00E+00 1.89E+06 0.00E+00 1.23E+06 0.00E+00 PU-239 2.12E+07 2.27E+06 5.45E+05 0.00E+00 2.01E+06 0.00E+00 1.13E+06 0.00E+00 PU-240 2.11E+07 2.35E+06 5.45E+05 0.00E+00 2.01E+06 0.00E+00 1.15E+06 0.00E+00 PU-241 6.35E+05 2.59E+04 1.32E+04 0.00E+00 4.86E+04 0.00E+00 2.36E+04 0.00E+00 PU-242 1.96E+07 2.27E+06 5.25E+05 0.00E+00 1.93E+06 0.00E+00 1.10E+06 0.00E+00 PU-244 2.29E+07 2.60E+07 6.01E+05 0.00E+00 2.22E+06 0.00E+00 1.65E+06 0.00E+00 AM-241 5.59E+07 4.81E+07 4.20E+06 0.00E+00 2.56E+07 0.00E+00 3.14E+06 0.00E+00 AM-242m 5.76E+07 4.61E+07 4.28E+06 0.00E+00 2.59E+07 0.00E+00 3.95E+06 0.00E+00 AM-243 5.51E+07 4.65E+07 4.04E+06 0.00E+00 2.49E+07 0.00E+00 3.68E+06 0.00E+00 CM-242 3.30E+06 2.63E+06 2.19E+05 0.00E+00 7.02E+05 0.00E+00 3.07E+06 0.00E+00 CM-243 5.26E+07 4.27E+07 3.38E+06 0.00E+00 1.27E+07 0.00E+00 3.30E+06 0.00E+00 CM-244 4.43E+07 3.59E+07 2.84E+06 0.00E+00 1.04E+07 0.00E+00 3.19E+06 0.00E+00 CM-245 6.87E+07 5.51E+07 4.32E+06 0.00E+00 1.69E+07 0.00E+00 2.98E+06 0.00E+00 CM-246 6.79E+07 5.51E+07 4.32E+06 0.00E+00 1.69E+07 0.00E+00 2.92E+06 0.00E+00 CM-247 6.62E+07 5.43E+07 4.24E+06 0.00E+00 1.66E+07 0.00E+00 3.85E+06 0.00E+00 CM-248 5.51E+08 4.48E+08 3.50E+07 0.00E+00 1.37E+08 0.00E+00 6.21E+07 0.00E+00 CF-252 4.25E+07 0.00E+00 1.03E+06 0.00E+00 0.00E+00 0.00E+00 1.20E+07 0.00E+00 II.4-158 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-39 (Page 1 of 4)
Teen Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 5.66E+02 5.66E+02 5.66E+02 5.66E+02 5.66E+02 5.66E+02 0.00E+00 C-14 6.70E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 0.00E+00 NA-22 9.19E+09 9.19E+09 9.19E+09 9.19E+09 9.19E+09 9.19E+09 9.19E+09 0.00E+00 NA-24 4.26E+06 4.26E+06 4.26E+06 4.26E+06 4.26E+06 4.26E+06 4.26E+06 0.00E+00 P-32 3.15E+10 1.95E+09 1.22E+09 0.00E+00 0.00E+00 0.00E+00 2.65E+09 0.00E+00 CA-41 1.57E+10 0.00E+00 1.70E+09 0.00E+00 0.00E+00 0.00E+00 1.56E+07 0.00E+00 SC-46 3.04E+02 5.93E+02 1.76E+02 0.00E+00 5.67E+02 0.00E+00 2.02E+06 0.00E+00 CR-51 0.00E+00 0.00E+00 4.99E+04 2.77E+04 1.09E+04 7.13E+04 8.39E+06 0.00E+00 MN-54 0.00E+00 1.40E+07 2.78E+06 0.00E+00 4.18E+06 0.00E+00 2.87E+07 0.00E+00 FE-55 4.45E+07 3.16E+07 7.36E+06 0.00E+00 0.00E+00 2.00E+07 1.37E+07 0.00E+00 MN-56 0.00E+00 7.36E-03 1.31E-03 0.00E+00 9.31E-03 0.00E+00 4.84E-01 0.00E+00 CO-57 0.00E+00 2.25E+06 3.76E+06 0.00E+00 0.00E+00 0.00E+00 4.19E+07 0.00E+00 CO-58 0.00E+00 7.94E+06 1.83E+07 0.00E+00 0.00E+00 0.00E+00 1.09E+08 0.00E+00 FE-59 5.18E+07 1.21E+08 4.67E+07 0.00E+00 0.00E+00 3.81E+07 2.86E+08 0.00E+00 CO-60 0.00E+00 2.78E+07 6.26E+07 0.00E+00 0.00E+00 0.00E+00 3.62E+08 0.00E+00 NI-59 8.82E+08 3.11E+08 1.50E+08 0.00E+00 0.00E+00 0.00E+00 4.88E+07 0.00E+00 NI-63 1.18E+10 8.35E+08 4.01E+08 0.00E+00 0.00E+00 0.00E+00 1.33E+08 0.00E+00 CU-64 0.00E+00 4.25E+04 2.00E+04 0.00E+00 1.07E+05 0.00E+00 3.29E+06 0.00E+00 NI-65 6.77E-01 8.65E-02 3.94E-02 0.00E+00 0.00E+00 0.00E+00 4.69E+00 0.00E+00 ZN-65 2.11E+09 7.32E+09 3.41E+09 0.00E+00 4.68E+09 0.00E+00 3.10E+09 0.00E+00 ZN-69m 3.26E+05 7.69E+05 7.05E+04 0.00E+00 4.67E+05 0.00E+00 4.22E+07 0.00E+00 ZN-69 3.85E-12 7.34E-12 5.13E-13 0.00E+00 4.79E-12 0.00E+00 1.35E-11 0.00E+00 SE-79 0.00E+00 1.67E+09 2.81E+08 0.00E+00 2.92E+09 0.00E+00 2.56E+08 0.00E+00 BR-82 0.00E+00 0.00E+00 5.61E+07 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 1.79E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 2.88E-23 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 3.59E-301 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 4.73E+09 2.22E+09 0.00E+00 0.00E+00 0.00E+00 7.00E+08 0.00E+00 RB-87 0.00E+00 5.24E+09 1.83E+09 0.00E+00 0.00E+00 0.00E+00 1.83E+08 0.00E+00 RB-88 0.00E+00 3.89E-45 2.07E-45 0.00E+00 0.00E+00 0.00E+00 3.33E-52 0.00E+00 RB-89 0.00E+00 7.66E-53 5.42E-53 0.00E+00 0.00E+00 0.00E+00 1.17E-61 0.00E+00 SR-89 2.67E+09 0.00E+00 7.66E+07 0.00E+00 0.00E+00 0.00E+00 3.19E+08 0.00E+00 SR-90 8.13E+10 0.00E+00 1.63E+09 0.00E+00 0.00E+00 0.00E+00 1.86E+09 0.00E+00 Y-90 1.30E+02 0.00E+00 3.51E+00 0.00E+00 0.00E+00 0.00E+00 1.07E+06 0.00E+00 SR-91 5.31E+04 0.00E+00 2.11E+03 0.00E+00 0.00E+00 0.00E+00 2.41E+05 0.00E+00 Y-91m 1.10E-19 0.00E+00 4.19E-21 0.00E+00 0.00E+00 0.00E+00 5.17E-18 0.00E+00 Y-91 1.58E+04 0.00E+00 4.24E+02 0.00E+00 0.00E+00 0.00E+00 6.48E+06 0.00E+00 II.4-159 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-39 (Page 2 of 4)
Teen Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 8.94E-01 0.00E+00 3.81E-02 0.00E+00 0.00E+00 0.00E+00 2.28E+01 0.00E+00 Y-92 1.03E-04 0.00E+00 2.98E-06 0.00E+00 0.00E+00 0.00E+00 2.83E+00 0.00E+00 Y-93 4.12E-01 0.00E+00 1.13E-02 0.00E+00 0.00E+00 0.00E+00 1.26E+04 0.00E+00 NB-93m 8.55E+05 2.81E+05 7.04E+04 0.00E+00 3.28E+05 0.00E+00 1.01E+08 0.00E+00 NB-95 1.41E+05 7.81E+04 4.30E+04 0.00E+00 7.57E+04 0.00E+00 3.34E+08 0.00E+00 NB-97 5.99E-12 1.49E-12 5.43E-13 0.00E+00 1.74E-12 0.00E+00 3.55E-08 0.00E+00 ZR-93 2.76E+03 1.36E+03 7.43E+02 0.00E+00 4.81E+03 0.00E+00 1.29E+06 0.00E+00 ZR-95 1.65E+03 5.20E+02 3.58E+02 0.00E+00 7.65E+02 0.00E+00 1.20E+06 0.00E+00 ZR-97 7.88E-01 1.56E-01 7.19E-02 0.00E+00 2.37E-01 0.00E+00 4.22E+04 0.00E+00 MO-93 0.00E+00 7.93E+08 2.17E+07 0.00E+00 2.27E+08 0.00E+00 9.65E+07 0.00E+00 MO-99 0.00E+00 4.47E+07 8.53E+06 0.00E+00 1.02E+08 0.00E+00 8.01E+07 0.00E+00 TC-99 4.46E+07 6.56E+07 1.79E+07 0.00E+00 8.33E+08 6.78E+06 1.61E+09 0.00E+00 TC-99m 5.76E+00 1.61E+01 2.08E+02 0.00E+00 2.39E+02 8.92E+00 1.05E+04 0.00E+00 TC-101 4.74E-60 6.74E-60 6.62E-59 0.00E+00 1.22E-58 4.11E-60 1.15E-66 0.00E+00 RU-103 1.81E+03 0.00E+00 7.74E+02 0.00E+00 6.38E+03 0.00E+00 1.51E+05 0.00E+00 RU-105 1.56E-03 0.00E+00 6.07E-04 0.00E+00 1.97E-02 0.00E+00 1.26E+00 0.00E+00 RU-106 3.75E+04 0.00E+00 4.73E+03 0.00E+00 7.24E+04 0.00E+00 1.80E+06 0.00E+00 RH-105 6.40E+05 4.63E+05 3.04E+05 0.00E+00 1.97E+06 0.00E+00 5.89E+07 0.00E+00 PD-107 0.00E+00 2.07E+07 1.34E+06 0.00E+00 1.87E+08 0.00E+00 9.63E+07 0.00E+00 PD-109 0.00E+00 8.10E+04 1.84E+04 0.00E+00 4.68E+05 0.00E+00 8.17E+06 0.00E+00 AG-110m 9.63E+07 9.11E+07 5.54E+07 0.00E+00 1.74E+08 0.00E+00 2.56E+10 0.00E+00 AG-111 1.19E+07 4.95E+06 2.49E+06 0.00E+00 1.61E+07 0.00E+00 6.91E+09 0.00E+00 CD-113m 0.00E+00 5.38E+06 1.73E+05 0.00E+00 5.95E+06 0.00E+00 3.23E+07 0.00E+00 CD-115m 0.00E+00 2.30E+06 7.41E+04 0.00E+00 1.84E+06 0.00E+00 7.27E+07 0.00E+00 SN-123 9.88E+08 1.62E+07 2.40E+07 1.30E+07 0.00E+00 0.00E+00 1.49E+09 0.00E+00 SN-125 1.05E+08 2.09E+06 4.73E+06 1.64E+06 0.00E+00 0.00E+00 9.86E+08 0.00E+00 SN-126 2.89E+09 5.39E+07 8.23E+07 1.42E+07 0.00E+00 0.00E+00 6.43E+08 0.00E+00 SB-124 4.59E+07 8.46E+05 1.79E+07 1.04E+05 0.00E+00 4.01E+07 9.25E+08 0.00E+00 SB-125 3.65E+07 3.99E+05 8.55E+06 3.49E+04 0.00E+00 3.21E+07 2.84E+08 0.00E+00 SB-126 9.99E+06 2.04E+05 3.59E+06 5.65E+04 0.00E+00 7.16E+06 5.91E+08 0.00E+00 SB-127 8.17E+05 1.75E+04 3.08E+05 9.18E+03 0.00E+00 5.56E+05 1.39E+08 0.00E+00 TE-125m 3.00E+07 1.08E+07 4.02E+06 8.39E+06 0.00E+00 0.00E+00 8.86E+07 0.00E+00 TE-127m 8.44E+07 2.99E+07 1.00E+07 2.01E+07 3.42E+08 0.00E+00 2.10E+08 0.00E+00 TE-127 1.21E+03 4.29E+02 2.60E+02 8.35E+02 4.90E+03 0.00E+00 9.34E+04 0.00E+00 TE-129m 1.10E+08 4.09E+07 1.74E+07 3.55E+07 4.61E+08 0.00E+00 4.13E+08 0.00E+00 TE-129 5.20E-10 1.94E-10 1.26E-10 3.71E-10 2.18E-09 0.00E+00 2.84E-09 0.00E+00 TE-133m 3.79E-13 2.15E-13 2.09E-13 3.00E-13 2.13E-12 0.00E+00 8.70E-13 0.00E+00 II.4-160 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-39 (Page 3 of 4)
Teen Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 1.59E-18 1.02E-18 1.06E-18 1.30E-18 9.72E-18 0.00E+00 5.89E-20 0.00E+00 I-129 1.39E+09 1.17E+09 1.96E+09 1.43E+12 2.10E+09 0.00E+00 1.37E+08 0.00E+00 I-130 7.38E+05 2.14E+06 8.53E+05 1.74E+08 3.29E+06 0.00E+00 1.64E+06 0.00E+00 I-131 5.37E+08 7.52E+08 4.04E+08 2.19E+11 1.29E+09 0.00E+00 1.49E+08 0.00E+00 TE-131m 6.57E+05 3.15E+05 2.63E+05 4.74E+05 3.29E+06 0.00E+00 2.53E+07 0.00E+00 TE-131 6.58E-33 2.71E-33 2.06E-33 5.07E-33 2.88E-32 0.00E+00 5.40E-34 0.00E+00 I-132 2.91E-01 7.62E-01 2.74E-01 2.57E+01 1.20E+00 0.00E+00 3.32E-01 0.00E+00 TE-132 4.29E+06 2.72E+06 2.56E+06 2.87E+06 2.61E+07 0.00E+00 8.61E+07 0.00E+00 I-133 7.07E+06 1.20E+07 3.66E+06 1.67E+09 2.10E+07 0.00E+00 9.07E+06 0.00E+00 CS-134m 3.09E-01 6.41E-01 3.29E-01 0.00E+00 3.57E-01 6.26E-02 4.26E-01 0.00E+00 CS-134 9.82E+09 2.31E+10 1.07E+10 0.00E+00 7.34E+09 2.80E+09 2.87E+08 0.00E+00 I-134 3.58E-12 9.50E-12 3.41E-12 1.58E-10 1.50E-11 0.00E+00 1.25E-13 0.00E+00 I-135 2.28E+04 5.87E+04 2.18E+04 3.78E+06 9.27E+04 0.00E+00 6.51E+04 0.00E+00 CS-135 3.33E+09 3.05E+09 7.13E+08 0.00E+00 1.16E+09 4.21E+08 5.34E+07 0.00E+00 CS-136 4.48E+08 1.76E+09 1.18E+09 0.00E+00 9.60E+08 1.51E+08 1.42E+08 0.00E+00 CS-137 1.34E+10 1.78E+10 6.20E+09 0.00E+00 6.06E+09 2.35E+09 2.53E+08 0.00E+00 CS-138 1.64E-23 3.15E-23 1.57E-23 0.00E+00 2.33E-23 2.71E-24 1.43E-26 0.00E+00 CS-139 1.25E-89 1.84E-89 6.75E-90 0.00E+00 1.49E-89 1.63E-90 8.54E-105 0.00E+00 BA-139 8.17E-08 5.75E-11 2.38E-09 0.00E+00 5.42E-11 3.96E-11 7.29E-07 0.00E+00 BA-140 4.85E+07 5.95E+04 3.13E+06 0.00E+00 2.02E+04 4.00E+04 7.48E+07 0.00E+00 LA-140 8.10E+00 3.98E+00 1.06E+00 0.00E+00 0.00E+00 0.00E+00 2.29E+05 0.00E+00 BA-141 7.52E-46 5.62E-49 2.51E-47 0.00E+00 5.21E-49 3.85E-49 1.60E-51 0.00E+00 LA-141 5.60E-05 1.72E-05 2.84E-06 0.00E+00 0.00E+00 0.00E+00 3.05E+00 0.00E+00 CE-141 8.88E+03 5.93E+03 6.81E+02 0.00E+00 2.79E+03 0.00E+00 1.70E+07 0.00E+00 BA-142 4.81E-80 4.81E-83 2.96E-81 0.00E+00 4.07E-83 3.20E-83 1.48E-91 0.00E+00 LA-142 3.35E-11 1.49E-11 3.71E-12 0.00E+00 0.00E+00 0.00E+00 4.53E-07 0.00E+00 CE-143 7.64E+01 5.56E+04 6.21E+00 0.00E+00 2.49E+01 0.00E+00 1.67E+06 0.00E+00 PR-143 2.90E+02 1.16E+02 1.44E+01 0.00E+00 6.73E+01 0.00E+00 9.54E+05 0.00E+00 CE-144 6.58E+05 2.72E+05 3.54E+04 0.00E+00 1.63E+05 0.00E+00 1.66E+08 0.00E+00 PR-144 1.08E-53 4.43E-54 5.48E-55 0.00E+00 2.54E-54 0.00E+00 1.19E-56 0.00E+00 ND-147 1.81E+02 1.97E+02 1.18E+01 0.00E+00 1.16E+02 0.00E+00 7.11E+05 0.00E+00 PM-147 5.15E+03 4.89E+02 1.99E+02 0.00E+00 9.32E+02 0.00E+00 4.65E+05 0.00E+00 PM-148m 1.49E+03 3.78E+02 2.96E+02 0.00E+00 5.73E+02 0.00E+00 2.38E+06 0.00E+00 PM-148 1.09E+02 1.77E+01 8.92E+00 0.00E+00 3.20E+01 0.00E+00 1.06E+06 0.00E+00 PM-149 7.88E+00 1.11E+00 4.54E-01 0.00E+00 2.11E+00 0.00E+00 1.63E+05 0.00E+00 PM-151 1.19E+00 1.96E-01 9.92E-02 0.00E+00 3.52E-01 0.00E+00 4.40E+04 0.00E+00 SM-151 4.35E+03 8.37E+02 1.96E+02 0.00E+00 9.17E+02 0.00E+00 2.84E+05 0.00E+00 II.4-161 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-39 (Page 4 of 4)
Teen Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 3.64E+00 3.01E+00 2.22E-01 0.00E+00 9.84E-01 0.00E+00 8.50E+04 0.00E+00 EU-152 1.22E+04 2.93E+03 2.58E+03 0.00E+00 1.36E+04 0.00E+00 1.08E+06 0.00E+00 EU-154 3.93E+04 5.06E+03 3.57E+03 0.00E+00 2.26E+04 0.00E+00 2.67E+06 0.00E+00 EU-155 8.60E+03 8.31E+02 5.14E+02 0.00E+00 3.25E+03 0.00E+00 4.76E+06 0.00E+00 EU-156 4.55E+02 3.41E+02 5.57E+01 0.00E+00 2.29E+02 0.00E+00 1.74E+06 0.00E+00 TB-160 2.65E+03 0.00E+00 3.31E+02 0.00E+00 1.05E+03 0.00E+00 1.72E+06 0.00E+00 HO-166m 1.78E+04 5.48E+03 3.97E+03 0.00E+00 8.03E+03 0.00E+00 4.99E-14 0.00E+00 W-181 6.27E+04 2.02E+04 2.12E+03 0.00E+00 0.00E+00 0.00E+00 1.72E+06 0.00E+00 W-185 2.39E+06 7.88E+05 8.33E+04 0.00E+00 0.00E+00 0.00E+00 6.81E+07 0.00E+00 W-187 1.19E+04 9.71E+03 3.40E+03 0.00E+00 0.00E+00 0.00E+00 2.63E+06 0.00E+00 NP-239 7.01E+00 6.61E-01 3.67E-01 0.00E+00 2.07E+00 0.00E+00 1.06E+05 0.00E+00 U-232 2.94E+10 0.00E+00 2.10E+09 0.00E+00 3.18E+09 0.00E+00 3.58E+08 0.00E+00 U-233 6.18E+09 0.00E+00 3.76E+08 0.00E+00 1.45E+09 0.00E+00 3.32E+08 0.00E+00 U-234 5.93E+09 0.00E+00 3.68E+08 0.00E+00 1.42E+09 0.00E+00 3.25E+08 0.00E+00 U-235 5.68E+09 0.00E+00 3.46E+08 0.00E+00 1.33E+09 0.00E+00 4.13E+08 0.00E+00 U-236 5.68E+09 0.00E+00 3.54E+08 0.00E+00 1.36E+09 0.00E+00 3.05E+08 0.00E+00 U-237 1.04E+05 0.00E+00 2.77E+04 0.00E+00 4.28E+05 0.00E+00 2.76E+07 0.00E+00 U-238 5.44E+09 0.00E+00 3.24E+08 0.00E+00 1.25E+09 0.00E+00 2.91E+08 0.00E+00 NP-237 6.63E+07 4.76E+06 2.92E+06 0.00E+00 2.16E+07 0.00E+00 4.19E+06 0.00E+00 NP-238 6.63E+01 1.77E+00 1.03E+00 0.00E+00 6.09E+00 0.00E+00 1.30E+05 0.00E+00 PU-238 1.34E+07 1.71E+06 3.63E+05 0.00E+00 1.55E+06 0.00E+00 1.54E+06 0.00E+00 PU-239 1.53E+07 1.85E+06 4.01E+05 0.00E+00 1.71E+06 0.00E+00 1.41E+06 0.00E+00 PU-240 1.52E+07 1.85E+06 4.01E+05 0.00E+00 1.71E+06 0.00E+00 1.43E+06 0.00E+00 PU-241 3.48E+05 1.67E+04 7.34E+03 0.00E+00 3.40E+04 0.00E+00 2.94E+04 0.00E+00 PU-242 1.41E+07 1.78E+06 3.87E+05 0.00E+00 1.65E+06 0.00E+00 1.38E+06 0.00E+00 PU-244 1.65E+07 2.03E+06 4.43E+05 0.00E+00 1.88E+06 0.00E+00 2.05E+06 0.00E+00 AM-241 3.98E+07 3.75E+07 2.87E+06 0.00E+00 2.15E+07 0.00E+00 3.92E+06 0.00E+00 AM-242m 4.02E+07 3.54E+07 2.89E+06 0.00E+00 2.14E+07 0.00E+00 4.94E+06 0.00E+00 AM-243 3.97E+07 3.66E+07 2.80E+06 0.00E+00 2.10E+07 0.00E+00 4.60E+06 0.00E+00 CM-242 1.34E+06 1.41E+06 8.88E+04 0.00E+00 4.05E+05 0.00E+00 3.82E+06 0.00E+00 CM-243 3.24E+07 3.00E+07 2.04E+06 0.00E+00 9.51E+06 0.00E+00 4.12E+06 0.00E+00 CM-244 2.51E+07 2.37E+07 1.59E+06 0.00E+00 7.41E+06 0.00E+00 3.98E+06 0.00E+00 CM-245 4.94E+07 4.34E+07 3.04E+06 0.00E+00 1.42E+07 0.00E+00 3.72E+06 0.00E+00 CM-246 4.90E+07 4.34E+07 3.04E+06 0.00E+00 1.42E+07 0.00E+00 3.65E+06 0.00E+00 CM-247 4.77E+07 4.27E+07 2.99E+06 0.00E+00 1.40E+07 0.00E+00 4.80E+06 0.00E+00 CM-248 3.96E+08 3.52E+08 2.47E+07 0.00E+00 1.15E+08 0.00E+00 7.73E+07 0.00E+00 CF-252 1.70E+07 0.00E+00 4.11E+05 0.00E+00 0.00E+00 0.00E+00 1.50E+07 0.00E+00 II.4-162 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-40 (Page 1 of 4)
Adult Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 4.35E+02 4.35E+02 4.35E+02 4.35E+02 4.35E+02 4.35E+02 0.00E+00 C-14 3.63E+05 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 0.00E+00 NA-22 5.29E+09 5.29E+09 5.29E+09 5.29E+09 5.29E+09 5.29E+09 5.29E+09 0.00E+00 NA-24 2.44E+06 2.44E+06 2.44E+06 2.44E+06 2.44E+06 2.44E+06 2.44E+06 0.00E+00 P-32 1.71E+10 1.06E+09 6.61E+08 0.00E+00 0.00E+00 0.00E+00 1.92E+09 0.00E+00 CA-41 1.14E+10 0.00E+00 1.24E+09 0.00E+00 0.00E+00 0.00E+00 1.14E+07 0.00E+00 SC-46 1.79E+02 3.48E+02 1.01E+02 0.00E+00 3.25E+02 0.00E+00 1.70E+06 0.00E+00 CR-51 0.00E+00 0.00E+00 2.86E+04 1.71E+04 6.30E+03 3.79E+04 7.19E+06 0.00E+00 MN-54 0.00E+00 8.41E+06 1.61E+06 0.00E+00 2.50E+06 0.00E+00 2.58E+07 0.00E+00 FE-55 2.51E+07 1.74E+07 4.05E+06 0.00E+00 0.00E+00 9.68E+06 9.95E+06 0.00E+00 MN-56 0.00E+00 4.15E-03 7.36E-04 0.00E+00 5.27E-03 0.00E+00 1.32E-01 0.00E+00 CO-57 0.00E+00 1.28E+06 2.13E+06 0.00E+00 0.00E+00 0.00E+00 3.25E+07 0.00E+00 CO-58 0.00E+00 4.71E+06 1.06E+07 0.00E+00 0.00E+00 0.00E+00 9.55E+07 0.00E+00 FE-59 2.97E+07 6.98E+07 2.68E+07 0.00E+00 0.00E+00 1.95E+07 2.33E+08 0.00E+00 CO-60 0.00E+00 1.64E+07 3.62E+07 0.00E+00 0.00E+00 0.00E+00 3.08E+08 0.00E+00 NI-59 5.05E+08 1.73E+08 8.44E+07 0.00E+00 0.00E+00 0.00E+00 3.57E+07 0.00E+00 NI-63 6.73E+09 4.66E+08 2.26E+08 0.00E+00 0.00E+00 0.00E+00 9.73E+07 0.00E+00 CU-64 0.00E+00 2.38E+04 1.12E+04 0.00E+00 6.01E+04 0.00E+00 2.03E+06 0.00E+00 NI-65 3.70E-01 4.81E-02 2.19E-02 0.00E+00 0.00E+00 0.00E+00 1.22E+00 0.00E+00 ZN-65 1.37E+09 4.37E+09 1.97E+09 0.00E+00 2.92E+09 0.00E+00 2.75E+09 0.00E+00 ZN-69m 1.79E+05 4.29E+05 3.93E+04 0.00E+00 2.60E+05 0.00E+00 2.62E+07 0.00E+00 ZN-69 2.09E-12 4.00E-12 2.78E-13 0.00E+00 2.60E-12 0.00E+00 6.01E-13 0.00E+00 SE-79 0.00E+00 9.15E+08 1.53E+08 0.00E+00 1.58E+09 0.00E+00 1.87E+08 0.00E+00 BR-82 0.00E+00 0.00E+00 3.23E+07 0.00E+00 0.00E+00 0.00E+00 3.70E+07 0.00E+00 BR-83 0.00E+00 0.00E+00 9.72E-02 0.00E+00 0.00E+00 0.00E+00 1.40E-01 0.00E+00 BR-84 0.00E+00 0.00E+00 1.61E-23 0.00E+00 0.00E+00 0.00E+00 1.26E-28 0.00E+00 BR-85 0.00E+00 0.00E+00 1.95E-301 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 2.59E+09 1.21E+09 0.00E+00 0.00E+00 0.00E+00 5.12E+08 0.00E+00 RB-87 0.00E+00 2.85E+09 9.92E+08 0.00E+00 0.00E+00 0.00E+00 1.34E+08 0.00E+00 RB-88 0.00E+00 2.14E-45 1.13E-45 0.00E+00 0.00E+00 0.00E+00 2.96E-56 0.00E+00 RB-89 0.00E+00 4.33E-53 3.05E-53 0.00E+00 0.00E+00 0.00E+00 2.52E-66 0.00E+00 SR-89 1.45E+09 0.00E+00 4.16E+07 0.00E+00 0.00E+00 0.00E+00 2.33E+08 0.00E+00 SR-90 5.38E+10 0.00E+00 1.08E+09 0.00E+00 0.00E+00 0.00E+00 1.35E+09 0.00E+00 Y-90 7.08E+01 0.00E+00 1.90E+00 0.00E+00 0.00E+00 0.00E+00 7.51E+05 0.00E+00 SR-91 2.89E+04 0.00E+00 1.17E+03 0.00E+00 0.00E+00 0.00E+00 1.38E+05 0.00E+00 Y-91m 5.98E-20 0.00E+00 2.32E-21 0.00E+00 0.00E+00 0.00E+00 1.76E-19 0.00E+00 Y-91 8.59E+03 0.00E+00 2.30E+02 0.00E+00 0.00E+00 0.00E+00 4.73E+06 0.00E+00 II.4-163 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-40 (Page 2 of 4)
Adult Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 4.88E-01 0.00E+00 2.11E-02 0.00E+00 0.00E+00 0.00E+00 9.68E+00 0.00E+00 Y-92 5.58E-05 0.00E+00 1.63E-06 0.00E+00 0.00E+00 0.00E+00 9.77E-01 0.00E+00 Y-93 2.23E-01 0.00E+00 6.17E-03 0.00E+00 0.00E+00 0.00E+00 7.08E+03 0.00E+00 NB-93m 4.91E+05 1.60E+05 3.95E+04 0.00E+00 1.84E+05 0.00E+00 7.40E+07 0.00E+00 NB-95 8.26E+04 4.59E+04 2.47E+04 0.00E+00 4.54E+04 0.00E+00 2.79E+08 0.00E+00 NB-97 3.29E-12 8.32E-13 3.04E-13 0.00E+00 9.71E-13 0.00E+00 3.07E-09 0.00E+00 ZR-93 1.62E+03 9.04E+01 4.21E+01 0.00E+00 3.43E+02 0.00E+00 9.39E+04 0.00E+00 ZR-95 9.43E+02 3.03E+02 2.05E+02 0.00E+00 4.75E+02 0.00E+00 9.59E+05 0.00E+00 ZR-97 4.33E-01 8.74E-02 4.00E-02 0.00E+00 1.32E-01 0.00E+00 2.71E+04 0.00E+00 MO-93 0.00E+00 4.35E+08 1.18E+07 0.00E+00 1.23E+08 0.00E+00 7.07E+07 0.00E+00 MO-99 0.00E+00 2.48E+07 4.71E+06 0.00E+00 5.61E+07 0.00E+00 5.74E+07 0.00E+00 TC-99 2.42E+07 3.59E+07 9.70E+06 0.00E+00 4.52E+08 3.05E+06 1.17E+09 0.00E+00 TC-99m 3.32E+00 9.38E+00 1.20E+02 0.00E+00 1.43E+02 4.60E+00 5.55E+03 0.00E+00 TC-101 2.59E-60 3.74E-60 3.66E-59 0.00E+00 6.73E-59 1.91E-60 1.12E-71 0.00E+00 RU-103 1.02E+03 0.00E+00 4.39E+02 0.00E+00 3.89E+03 0.00E+00 1.19E+05 0.00E+00 RU-105 8.57E-04 0.00E+00 3.38E-04 0.00E+00 1.11E-02 0.00E+00 5.24E-01 0.00E+00 RU-106 2.04E+04 0.00E+00 2.58E+03 0.00E+00 3.94E+04 0.00E+00 1.32E+06 0.00E+00 RH-105 3.47E+05 2.54E+05 1.67E+05 0.00E+00 1.08E+06 0.00E+00 4.04E+07 0.00E+00 PD-107 0.00E+00 1.14E+07 7.27E+05 0.00E+00 1.02E+08 0.00E+00 7.04E+07 0.00E+00 PD-109 0.00E+00 4.43E+04 9.98E+03 0.00E+00 2.53E+05 0.00E+00 4.90E+06 0.00E+00 AG-110m 5.82E+07 5.39E+07 3.20E+07 0.00E+00 1.06E+08 0.00E+00 2.20E+10 0.00E+00 AG-111 6.48E+06 2.71E+06 1.35E+06 0.00E+00 8.74E+06 0.00E+00 4.97E+09 0.00E+00 CD-113m 0.00E+00 2.94E+06 9.43E+04 0.00E+00 3.24E+06 0.00E+00 2.37E+07 0.00E+00 CD-115m 0.00E+00 1.26E+06 4.02E+04 0.00E+00 9.99E+05 0.00E+00 5.30E+07 0.00E+00 SN-123 5.36E+08 8.88E+06 1.31E+07 7.55E+06 0.00E+00 0.00E+00 1.09E+09 0.00E+00 SN-125 5.68E+07 1.15E+06 2.58E+06 9.48E+05 0.00E+00 0.00E+00 7.10E+08 0.00E+00 SN-126 1.63E+09 3.23E+07 4.64E+07 9.51E+06 0.00E+00 0.00E+00 4.70E+08 0.00E+00 SB-124 2.57E+07 4.86E+05 1.02E+07 6.24E+04 0.00E+00 2.00E+07 7.31E+08 0.00E+00 SB-125 2.04E+07 2.28E+05 4.86E+06 2.08E+04 0.00E+00 1.58E+07 2.25E+08 0.00E+00 SB-126 5.60E+06 1.14E+05 2.02E+06 3.43E+04 0.00E+00 3.43E+06 4.58E+08 0.00E+00 SB-127 4.50E+05 9.85E+03 1.73E+05 5.41E+03 0.00E+00 2.67E+05 1.03E+08 0.00E+00 TE-125m 1.63E+07 5.90E+06 2.18E+06 4.90E+06 6.63E+07 0.00E+00 6.50E+07 0.00E+00 TE-127m 4.58E+07 1.64E+07 5.58E+06 1.17E+07 1.86E+08 0.00E+00 1.54E+08 0.00E+00 TE-127 6.53E+02 2.34E+02 1.41E+02 4.84E+02 2.66E+03 0.00E+00 5.15E+04 0.00E+00 TE-129m 6.02E+07 2.25E+07 9.53E+06 2.07E+07 2.51E+08 0.00E+00 3.03E+08 0.00E+00 TE-129 2.82E-10 1.06E-10 6.88E-11 2.17E-10 1.19E-09 0.00E+00 2.13E-10 0.00E+00 TE-133m 2.10E-13 1.23E-13 1.18E-13 1.78E-13 1.22E-12 0.00E+00 4.22E-14 0.00E+00 II.4-164 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-40 (Page 3 of 4)
Adult Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 8.90E-19 5.83E-19 3.57E-19 7.78E-19 5.63E-18 0.00E+00 9.87E-22 0.00E+00 I-129 7.58E+08 6.52E+08 2.14E+09 1.68E+12 1.40E+09 0.00E+00 1.03E+08 0.00E+00 I-130 4.20E+05 1.24E+06 4.89E+05 1.05E+08 1.93E+06 0.00E+00 1.07E+06 0.00E+00 I-131 2.96E+08 4.23E+08 2.43E+08 1.39E+11 7.26E+08 0.00E+00 1.12E+08 0.00E+00 TE-131m 3.61E+05 1.77E+05 1.47E+05 2.80E+05 1.79E+06 0.00E+00 1.75E+07 0.00E+00 TE-131 3.60E-33 1.51E-33 1.14E-33 2.96E-33 1.58E-32 0.00E+00 5.10E-34 0.00E+00 I-132 1.64E-01 4.39E-01 1.54E-01 1.54E+01 7.00E-01 0.00E+00 8.25E-02 0.00E+00 TE-132 2.40E+06 1.55E+06 1.46E+06 1.72E+06 1.50E+07 0.00E+00 7.35E+07 0.00E+00 I-133 3.87E+06 6.73E+06 2.05E+06 9.89E+08 1.17E+07 0.00E+00 6.05E+06 0.00E+00 CS-134m 1.74E-01 3.65E-01 1.87E-01 0.00E+00 1.98E-01 3.12E-02 1.29E-01 0.00E+00 CS-134 5.65E+09 1.35E+10 1.10E+10 0.00E+00 4.35E+09 1.45E+09 2.35E+08 0.00E+00 I-134 2.02E-12 5.48E-12 1.96E-12 9.49E-11 8.71E-12 0.00E+00 4.77E-15 0.00E+00 I-135 1.28E+04 3.36E+04 1.24E+04 2.22E+06 5.39E+04 0.00E+00 3.80E+04 0.00E+00 CS-135 1.81E+09 1.67E+09 7.41E+08 0.00E+00 6.32E+08 1.89E+08 3.90E+07 0.00E+00 CS-136 2.63E+08 1.04E+09 7.48E+08 0.00E+00 5.78E+08 7.93E+07 1.18E+08 0.00E+00 CS-137 7.38E+09 1.01E+10 6.61E+09 0.00E+00 3.43E+09 1.14E+09 1.95E+08 0.00E+00 CS-138 9.04E-24 1.79E-23 8.85E-24 0.00E+00 1.31E-23 1.30E-24 7.62E-29 0.00E+00 CS-139 6.78E-90 1.01E-89 3.68E-90 0.00E+00 8.09E-90 7.36E-91 2.19E-112 0.00E+00 BA-139 4.42E-08 3.15E-11 1.29E-09 0.00E+00 2.94E-11 1.79E-11 7.84E-08 0.00E+00 BA-140 2.69E+07 3.38E+04 1.76E+06 0.00E+00 1.15E+04 1.93E+04 5.53E+07 0.00E+00 LA-140 4.51E+00 2.27E+00 6.01E-01 0.00E+00 0.00E+00 0.00E+00 1.67E+05 0.00E+00 BA-141 4.09E-46 3.09E-49 1.38E-47 0.00E+00 2.88E-49 1.76E-49 1.93E-55 0.00E+00 LA-141 3.04E-05 9.44E-06 1.55E-06 0.00E+00 0.00E+00 0.00E+00 1.13E+00 0.00E+00 CE-141 4.84E+03 3.28E+03 3.72E+02 0.00E+00 1.52E+03 0.00E+00 1.25E+07 0.00E+00 BA-142 2.66E-80 2.73E-83 1.67E-81 0.00E+00 2.31E-83 1.55E-83 3.74E-98 0.00E+00 LA-142 1.86E-11 8.45E-12 2.10E-12 0.00E+00 0.00E+00 0.00E+00 6.17E-08 0.00E+00 CE-143 4.16E+01 3.07E+04 3.40E+00 0.00E+00 1.35E+01 0.00E+00 1.15E+06 0.00E+00 PR-143 1.58E+02 6.33E+01 7.83E+00 0.00E+00 3.66E+01 0.00E+00 6.92E+05 0.00E+00 CE-144 3.58E+05 1.50E+05 1.92E+04 0.00E+00 8.87E+04 0.00E+00 1.21E+08 0.00E+00 PR-144 5.87E-54 2.44E-54 2.98E-55 0.00E+00 1.37E-54 0.00E+00 8.44E-61 0.00E+00 ND-147 9.42E+01 1.09E+02 6.51E+00 0.00E+00 6.36E+01 0.00E+00 5.22E+05 0.00E+00 PM-147 2.87E+03 2.70E+02 1.09E+02 0.00E+00 5.10E+02 0.00E+00 3.40E+05 0.00E+00 PM-148m 8.57E+02 2.22E+02 1.70E+02 0.00E+00 3.35E+02 0.00E+00 1.88E+06 0.00E+00 PM-148 5.93E+01 9.84E+00 4.96E+00 0.00E+00 1.86E+01 0.00E+00 7.74E+05 0.00E+00 PM-149 4.28E+00 6.05E-01 2.47E-01 0.00E+00 1.14E+00 0.00E+00 1.13E+05 0.00E+00 PM-151 6.50E-01 1.09E-01 5.51E-02 0.00E+00 1.95E-01 0.00E+00 3.00E+04 0.00E+00 SM-151 2.67E+03 4.60E+02 1.10E+02 0.00E+00 5.14E+02 0.00E+00 2.03E+05 0.00E+00 II.4-165 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-40 (Page 4 of 4)
Adult Milk Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.98E+00 1.65E+00 1.21E-01 0.00E+00 5.34E-01 0.00E+00 5.89E+04 0.00E+00 EU-152 7.51E+03 1.71E+03 1.50E+03 0.00E+00 1.06E+04 0.00E+00 9.86E+05 0.00E+00 EU-154 2.37E+04 2.91E+03 2.07E+03 0.00E+00 1.39E+04 0.00E+00 2.11E+06 0.00E+00 EU-155 3.30E+03 4.67E+02 3.02E+02 0.00E+00 2.16E+03 0.00E+00 3.68E+05 0.00E+00 EU-156 2.51E+02 1.95E+02 3.14E+01 0.00E+00 1.30E+02 0.00E+00 1.33E+06 0.00E+00 TB-160 1.49E+03 0.00E+00 1.86E+02 0.00E+00 6.16E+02 0.00E+00 8.13E+05 0.00E+00 HO-166m 1.04E+04 3.26E+03 2.47E+03 0.00E+00 4.87E+03 0.00E+00 3.86E-14 0.00E+00 W-181 3.39E+04 1.11E+04 1.18E+03 0.00E+00 0.00E+00 0.00E+00 1.26E+06 0.00E+00 W-185 1.29E+06 4.32E+05 4.54E+04 0.00E+00 0.00E+00 0.00E+00 4.99E+07 0.00E+00 W-187 6.51E+03 5.45E+03 1.90E+03 0.00E+00 0.00E+00 0.00E+00 1.78E+06 0.00E+00 NP-239 3.67E+00 3.61E-01 1.99E-01 0.00E+00 1.13E+00 0.00E+00 7.41E+04 0.00E+00 U-232 1.60E+10 0.00E+00 1.14E+09 0.00E+00 1.73E+09 0.00E+00 2.62E+08 0.00E+00 U-233 3.37E+09 0.00E+00 2.04E+08 0.00E+00 7.84E+08 0.00E+00 2.42E+08 0.00E+00 U-234 3.23E+09 0.00E+00 2.00E+08 0.00E+00 7.69E+08 0.00E+00 2.37E+08 0.00E+00 U-235 3.10E+09 0.00E+00 1.88E+08 0.00E+00 7.23E+08 0.00E+00 3.02E+08 0.00E+00 U-236 3.10E+09 0.00E+00 1.92E+08 0.00E+00 7.38E+08 0.00E+00 2.23E+08 0.00E+00 U-237 5.65E+04 0.00E+00 1.50E+04 0.00E+00 2.32E+05 0.00E+00 1.99E+07 0.00E+00 U-238 2.96E+09 0.00E+00 1.75E+08 0.00E+00 6.76E+08 0.00E+00 2.13E+08 0.00E+00 NP-237 4.87E+07 3.46E+06 2.14E+06 0.00E+00 1.59E+07 0.00E+00 3.07E+06 0.00E+00 NP-238 3.61E+01 9.72E-01 5.61E-01 0.00E+00 3.29E+00 0.00E+00 9.04E+04 0.00E+00 PU-238 9.73E+06 1.23E+06 2.64E+05 0.00E+00 1.13E+06 0.00E+00 1.13E+06 0.00E+00 PU-239 1.12E+07 1.35E+06 2.95E+05 0.00E+00 1.25E+06 0.00E+00 1.03E+06 0.00E+00 PU-240 1.12E+07 1.34E+06 2.95E+05 0.00E+00 1.25E+06 0.00E+00 1.05E+06 0.00E+00 PU-241 2.42E+05 1.15E+04 5.12E+03 0.00E+00 2.36E+04 0.00E+00 2.16E+04 0.00E+00 PU-242 1.04E+07 1.30E+06 2.84E+05 0.00E+00 1.21E+06 0.00E+00 1.01E+06 0.00E+00 PU-244 1.21E+07 1.49E+06 3.26E+05 0.00E+00 1.38E+06 0.00E+00 1.50E+06 0.00E+00 AM-241 2.92E+07 2.72E+07 2.09E+06 0.00E+00 1.57E+07 0.00E+00 2.87E+06 0.00E+00 AM-242m 2.94E+07 2.56E+07 2.10E+06 0.00E+00 1.56E+07 0.00E+00 3.61E+06 0.00E+00 AM-243 2.91E+07 2.67E+07 2.05E+06 0.00E+00 1.54E+07 0.00E+00 3.36E+06 0.00E+00 CM-242 7.27E+05 7.73E+05 4.83E+04 0.00E+00 2.19E+05 0.00E+00 2.79E+06 0.00E+00 CM-243 2.31E+07 2.12E+07 1.45E+06 0.00E+00 6.75E+06 0.00E+00 3.01E+06 0.00E+00 CM-244 1.76E+07 1.65E+07 1.11E+06 0.00E+00 5.17E+06 0.00E+00 2.91E+06 0.00E+00 CM-245 3.62E+07 3.16E+07 2.23E+06 0.00E+00 1.04E+07 0.00E+00 2.72E+06 0.00E+00 CM-246 3.59E+07 3.15E+07 2.22E+06 0.00E+00 1.04E+07 0.00E+00 2.67E+06 0.00E+00 CM-247 3.50E+07 3.11E+07 2.19E+06 0.00E+00 1.02E+07 0.00E+00 3.51E+06 0.00E+00 CM-248 2.91E+08 2.56E+08 1.80E+07 0.00E+00 8.42E+07 0.00E+00 5.68E+07 0.00E+00 CF-252 9.93E+06 0.00E+00 2.39E+05 0.00E+00 0.00E+00 0.00E+00 1.10E+07 0.00E+00 II.4-166 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-41 (Page 1 of 4)
Infant Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C-14 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NA-22 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NA-24 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 P-32 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CA-41 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SC-46 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CR-51 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MN-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 FE-55 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MN-56 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-57 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-58 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 FE-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CO-60 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-63 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CU-64 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NI-65 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-65 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-69m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZN-69 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SE-79 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-82 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-87 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-90 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-90 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-91 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-91m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-91 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-167 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-41 (Page 2 of 4)
Infant Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-92 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Y-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-93m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-95 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-97 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-95 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ZR-97 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MO-93 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MO-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-99m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TC-101 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-103 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-105 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-106 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RH-105 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PD-107 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PD-109 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AG-110m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AG-111 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CD-113m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CD-115m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-123 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-125 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SN-126 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-124 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-125 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-126 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SB-127 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-125m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-127m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-127 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-129m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-133m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-168 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-41 (Page 3 of 4)
Infant Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-130 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-131m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-132 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TE-132 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-133 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-134m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-135 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-135 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-136 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-137 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-138 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CS-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-143 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PR-143 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PR-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND-147 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-147 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-148m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-148 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-149 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PM-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SM-151 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-169 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-41 (Page 4 of 4)
Infant Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-152 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-155 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EU-156 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TB-160 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 HO-166m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-181 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-185 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 W-187 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-239 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-232 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-233 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-234 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-235 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-236 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-237 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 U-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-237 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NP-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-238 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-239 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-240 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-241 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-242 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PU-244 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-241 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-242m 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 AM-243 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-242 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-243 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-244 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-245 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-246 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-247 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CM-248 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CF-252 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 II.4-170 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-42 (Page 1 of 4)
Child Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.34E+02 1.34E+02 0.00E+00 C-14 5.29E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 0.00E+00 NA-22 1.75E+09 1.75E+09 1.75E+09 1.75E+09 1.75E+09 1.75E+09 1.75E+09 0.00E+00 NA-24 1.72E-03 1.72E-03 1.72E-03 1.72E-03 1.72E-03 1.72E-03 1.72E-03 0.00E+00 P-32 7.42E+09 3.47E+08 2.86E+08 0.00E+00 0.00E+00 0.00E+00 2.05E+08 0.00E+00 CA-41 1.42E+09 0.00E+00 1.55E+08 0.00E+00 0.00E+00 0.00E+00 7.77E+05 0.00E+00 SC-46 2.34E+05 3.21E+05 1.24E+05 0.00E+00 2.84E+05 0.00E+00 4.69E+08 0.00E+00 CR-51 0.00E+00 0.00E+00 8.79E+03 4.88E+03 1.33E+03 8.91E+03 4.66E+05 0.00E+00 MN-54 0.00E+00 8.01E+06 2.13E+06 0.00E+00 2.25E+06 0.00E+00 6.72E+06 0.00E+00 FE-55 4.57E+08 2.42E+08 7.51E+07 0.00E+00 0.00E+00 1.37E+08 4.49E+07 0.00E+00 MN-56 0.00E+00 1.64E-53 3.70E-54 0.00E+00 1.98E-53 0.00E+00 2.38E-51 0.00E+00 CO-57 0.00E+00 5.92E+06 1.20E+07 0.00E+00 0.00E+00 0.00E+00 4.85E+07 0.00E+00 CO-58 0.00E+00 1.64E+07 5.02E+07 0.00E+00 0.00E+00 0.00E+00 9.58E+07 0.00E+00 FE-59 3.76E+08 6.09E+08 3.03E+08 0.00E+00 0.00E+00 1.77E+08 6.34E+08 0.00E+00 CO-60 0.00E+00 6.93E+07 2.04E+08 0.00E+00 0.00E+00 0.00E+00 3.84E+08 0.00E+00 NI-59 2.18E+08 5.80E+07 3.69E+07 0.00E+00 0.00E+00 0.00E+00 3.85E+06 0.00E+00 NI-63 2.91E+09 1.56E+08 9.91E+07 0.00E+00 0.00E+00 0.00E+00 1.05E+07 0.00E+00 CU-64 0.00E+00 2.97E-07 1.80E-07 0.00E+00 7.19E-07 0.00E+00 1.40E-05 0.00E+00 NI-65 3.52E-53 3.31E-54 1.93E-54 0.00E+00 0.00E+00 0.00E+00 4.06E-52 0.00E+00 ZN-65 3.75E+08 1.00E+09 6.22E+08 0.00E+00 6.30E+08 0.00E+00 1.76E+08 0.00E+00 ZN-69m 2.61E-05 4.45E-05 5.25E-06 0.00E+00 2.58E-05 0.00E+00 1.45E-03 0.00E+00 ZN-69 2.87E-153 4.15E-153 3.83E-154 0.00E+00 2.52E-153 0.00E+00 2.61E-151 0.00E+00 SE-79 0.00E+00 1.29E+08 2.87E+07 0.00E+00 2.10E+08 0.00E+00 8.48E+06 0.00E+00 BR-82 0.00E+00 0.00E+00 1.52E+03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 9.52E-57 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 9.37E-270 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 5.77E+08 3.55E+08 0.00E+00 0.00E+00 0.00E+00 3.71E+07 0.00E+00 RB-87 0.00E+00 1.25E+09 5.80E+08 0.00E+00 0.00E+00 0.00E+00 1.88E+07 0.00E+00 RB-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-89 4.82E+08 0.00E+00 1.38E+07 0.00E+00 0.00E+00 0.00E+00 1.87E+07 0.00E+00 SR-90 1.57E+10 0.00E+00 3.15E+08 0.00E+00 0.00E+00 0.00E+00 1.40E+08 0.00E+00 Y-90 1.71E+02 0.00E+00 4.59E+00 0.00E+00 0.00E+00 0.00E+00 4.88E+05 0.00E+00 SR-91 2.40E-10 0.00E+00 9.05E-12 0.00E+00 0.00E+00 0.00E+00 5.29E-10 0.00E+00 Y-91m 1.09E-174 0.00E+00 3.98E-176 0.00E+00 0.00E+00 0.00E+00 2.14E-171 0.00E+00 Y-91 1.80E+06 0.00E+00 4.82E+04 0.00E+00 0.00E+00 0.00E+00 2.40E+08 0.00E+00 II.4-171 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-42 (Page 2 of 4)
Child Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 1.84E-49 0.00E+00 7.39E-51 0.00E+00 0.00E+00 0.00E+00 3.49E-48 0.00E+00 Y-92 2.41E-39 0.00E+00 6.89E-41 0.00E+00 0.00E+00 0.00E+00 6.96E-35 0.00E+00 Y-93 7.44E-12 0.00E+00 2.04E-13 0.00E+00 0.00E+00 0.00E+00 1.11E-07 0.00E+00 NB-93m 2.99E+07 7.46E+06 2.45E+06 0.00E+00 8.06E+06 0.00E+00 1.12E+09 0.00E+00 NB-95 3.10E+06 1.21E+06 8.62E+05 0.00E+00 1.13E+06 0.00E+00 2.23E+09 0.00E+00 NB-97 9.14E-119 1.65E-119 7.71E-120 0.00E+00 1.83E-119 0.00E+00 5.10E-114 0.00E+00 ZR-93 5.80E+06 2.17E+06 1.55E+06 0.00E+00 8.41E+06 0.00E+00 8.24E+08 0.00E+00 ZR-95 2.66E+06 5.85E+05 5.21E+05 0.00E+00 8.38E+05 0.00E+00 6.11E+08 0.00E+00 ZR-97 3.21E-05 4.63E-06 2.73E-06 0.00E+00 6.65E-06 0.00E+00 7.02E-01 0.00E+00 MO-93 0.00E+00 1.97E+08 7.07E+06 0.00E+00 5.19E+07 0.00E+00 9.98E+06 0.00E+00 MO-99 0.00E+00 1.15E+05 2.84E+04 0.00E+00 2.46E+05 0.00E+00 9.51E+04 0.00E+00 TC-99 2.19E+08 2.44E+08 8.75E+07 0.00E+00 2.87E+09 2.15E+07 2.56E+09 0.00E+00 TC-99m 6.20E-21 1.22E-20 2.01E-19 0.00E+00 1.77E-19 6.17E-21 6.91E-18 0.00E+00 TC-101 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-103 1.55E+08 0.00E+00 5.96E+07 0.00E+00 3.90E+08 0.00E+00 4.01E+09 0.00E+00 RU-105 9.02E-28 0.00E+00 3.27E-28 0.00E+00 7.93E-27 0.00E+00 5.88E-25 0.00E+00 RU-106 4.44E+09 0.00E+00 5.54E+08 0.00E+00 5.99E+09 0.00E+00 6.90E+10 0.00E+00 RH-105 6.08E+00 3.27E+00 2.79E+00 0.00E+00 1.30E+01 0.00E+00 2.02E+02 0.00E+00 PD-107 0.00E+00 1.93E+06 1.64E+05 0.00E+00 1.62E+07 0.00E+00 3.83E+06 0.00E+00 PD-109 0.00E+00 1.58E-06 4.72E-07 0.00E+00 8.45E-06 0.00E+00 9.31E-05 0.00E+00 AG-110m 8.39E+06 5.67E+06 4.53E+06 0.00E+00 1.06E+07 0.00E+00 6.74E+08 0.00E+00 AG-111 2.33E+05 7.29E+04 4.81E+04 0.00E+00 2.20E+05 0.00E+00 4.46E+07 0.00E+00 CD-113m 0.00E+00 5.50E+06 2.34E+05 0.00E+00 5.66E+06 0.00E+00 1.42E+07 0.00E+00 CD-115m 0.00E+00 1.78E+06 7.58E+04 0.00E+00 1.32E+06 0.00E+00 2.42E+07 0.00E+00 SN-123 8.81E+09 1.09E+08 2.15E+08 1.16E+08 0.00E+00 0.00E+00 4.32E+09 0.00E+00 SN-125 2.81E+08 4.23E+06 1.26E+07 4.39E+06 0.00E+00 0.00E+00 8.69E+08 0.00E+00 SN-126 2.72E+10 3.39E+08 7.74E+08 9.32E+07 0.00E+00 0.00E+00 2.04E+09 0.00E+00 SB-124 2.92E+07 3.79E+05 1.02E+07 6.45E+04 0.00E+00 1.62E+07 1.83E+08 0.00E+00 SB-125 2.85E+07 2.20E+05 5.97E+06 2.64E+04 0.00E+00 1.59E+07 6.80E+07 0.00E+00 SB-126 2.76E+06 4.22E+04 9.91E+05 1.62E+04 0.00E+00 1.32E+06 5.56E+07 0.00E+00 SB-127 2.54E+04 3.93E+02 8.82E+03 2.83E+02 0.00E+00 1.10E+04 1.43E+06 0.00E+00 TE-125m 5.69E+08 1.54E+08 7.59E+07 1.60E+08 0.00E+00 0.00E+00 5.49E+08 0.00E+00 TE-127m 1.77E+09 4.78E+08 2.11E+08 4.24E+08 5.06E+09 0.00E+00 1.44E+09 0.00E+00 TE-127 3.39E-10 9.13E-11 7.26E-11 2.34E-10 9.63E-10 0.00E+00 1.32E-08 0.00E+00 TE-129m 1.79E+09 5.00E+08 2.78E+08 5.77E+08 5.26E+09 0.00E+00 2.18E+09 0.00E+00 TE-129 7.10E-121 1.98E-121 1.69E-121 5.07E-121 2.08E-120 0.00E+00 4.42E-119 0.00E+00 TE-133m 8.56E-153 3.46E-153 4.29E-153 6.64E-153 3.29E-152 0.00E+00 2.64E-151 0.00E+00 II.4-172 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-42 (Page 3 of 4)
Child Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 4.72E-204 2.12E-204 2.83E-204 3.73E-204 1.97E-203 0.00E+00 2.16E-203 0.00E+00 I-129 2.06E+08 1.26E+08 1.13E+08 8.27E+10 2.13E+08 0.00E+00 6.36E+06 0.00E+00 I-130 3.04E-06 6.13E-06 3.16E-06 6.76E-04 9.17E-06 0.00E+00 2.87E-06 0.00E+00 I-131 1.65E+07 1.66E+07 9.46E+06 5.50E+09 2.73E+07 0.00E+00 1.48E+06 0.00E+00 TE-131m 7.00E+02 2.42E+02 2.58E+02 4.98E+02 2.34E+03 0.00E+00 9.82E+03 0.00E+00 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-132 1.02E-58 1.88E-58 8.65E-59 8.72E-57 2.88E-58 0.00E+00 2.21E-58 0.00E+00 TE-132 2.12E+06 9.38E+05 1.13E+06 1.37E+06 8.71E+06 0.00E+00 9.45E+06 0.00E+00 I-133 5.67E-01 7.02E-01 2.66E-01 1.30E+02 1.17E+00 0.00E+00 2.83E-01 0.00E+00 CS-134m 3.86E-47 5.72E-47 3.73E-47 0.00E+00 3.02E-47 4.99E-48 7.23E-47 0.00E+00 CS-134 9.22E+08 1.51E+09 3.19E+08 0.00E+00 4.69E+08 1.68E+08 8.16E+06 0.00E+00 I-134 1.57E-161 2.91E-161 1.34E-161 6.70E-160 4.45E-161 0.00E+00 1.93E-161 0.00E+00 I-135 6.52E-17 1.17E-16 5.55E-17 1.04E-14 1.80E-16 0.00E+00 8.94E-17 0.00E+00 CS-135 3.39E+08 2.36E+08 2.42E+07 0.00E+00 8.34E+07 2.78E+07 1.77E+06 0.00E+00 CS-136 1.62E+07 4.46E+07 2.88E+07 0.00E+00 2.37E+07 3.54E+06 1.57E+06 0.00E+00 CS-137 1.33E+09 1.28E+09 1.88E+08 0.00E+00 4.16E+08 1.50E+08 7.99E+06 0.00E+00 CS-138 4.13E-267 5.75E-267 3.64E-267 0.00E+00 4.04E-267 4.35E-268 2.65E-267 0.00E+00 CS-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-139 1.98E-101 1.06E-104 5.73E-103 0.00E+00 9.22E-105 6.21E-105 1.14E-99 0.00E+00 BA-140 4.38E+07 3.84E+04 2.56E+06 0.00E+00 1.25E+04 2.29E+04 2.22E+07 0.00E+00 LA-140 5.59E-02 1.95E-02 6.58E-03 0.00E+00 0.00E+00 0.00E+00 5.44E+02 0.00E+00 BA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-141 6.19E-37 1.44E-37 3.13E-38 0.00E+00 0.00E+00 0.00E+00 3.21E-32 0.00E+00 CE-141 2.22E+04 1.11E+04 1.64E+03 0.00E+00 4.86E+03 0.00E+00 1.38E+07 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-142 5.26E-92 1.68E-92 5.25E-93 0.00E+00 0.00E+00 0.00E+00 3.32E-87 0.00E+00 CE-143 3.17E-02 1.72E+01 2.49E-03 0.00E+00 7.21E-03 0.00E+00 2.52E+02 0.00E+00 PR-143 3.34E+04 1.00E+04 1.66E+03 0.00E+00 5.43E+03 0.00E+00 3.60E+07 0.00E+00 CE-144 2.32E+06 7.26E+05 1.24E+05 0.00E+00 4.02E+05 0.00E+00 1.89E+08 0.00E+00 PR-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND-147 1.17E+04 9.47E+03 7.33E+02 0.00E+00 5.19E+03 0.00E+00 1.50E+07 0.00E+00 PM-147 1.52E+06 1.08E+05 5.81E+04 0.00E+00 1.91E+05 0.00E+00 4.38E+07 0.00E+00 PM-148m 2.70E+05 5.37E+04 5.37E+04 0.00E+00 7.96E+04 0.00E+00 1.51E+08 0.00E+00 PM-148 3.10E+03 3.72E+02 2.41E+02 0.00E+00 6.33E+02 0.00E+00 9.95E+06 0.00E+00 PM-149 8.18E+00 8.69E-01 4.71E-01 0.00E+00 1.54E+00 0.00E+00 5.93E+04 0.00E+00 PM-151 9.00E-03 1.09E-03 7.12E-04 0.00E+00 1.86E-03 0.00E+00 1.24E+02 0.00E+00 SM-151 1.31E+06 1.95E+05 6.13E+04 0.00E+00 2.01E+05 0.00E+00 2.82E+07 0.00E+00 II.4-173 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-42 (Page 4 of 4)
Child Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.82E+00 1.13E+00 1.09E-01 0.00E+00 3.44E-01 0.00E+00 1.50E+04 0.00E+00 EU-152 3.00E+06 5.46E+05 6.49E+05 0.00E+00 2.31E+06 0.00E+00 8.98E+07 0.00E+00 EU-154 1.12E+07 1.01E+06 9.19E+05 0.00E+00 4.42E+06 0.00E+00 2.34E+08 0.00E+00 EU-155 2.33E+06 1.68E+05 1.31E+05 0.00E+00 6.28E+05 0.00E+00 4.20E+08 0.00E+00 EU-156 5.75E+04 3.08E+04 6.38E+03 0.00E+00 1.99E+04 0.00E+00 6.99E+07 0.00E+00 TB-160 5.16E+05 0.00E+00 6.41E+04 0.00E+00 1.54E+05 0.00E+00 1.14E+08 0.00E+00 HO-166m 4.86E+06 1.02E+06 8.59E+05 0.00E+00 1.45E+06 0.00E+00 4.50E-12 0.00E+00 W-181 4.49E+04 1.10E+04 1.52E+03 0.00E+00 0.00E+00 0.00E+00 4.02E+05 0.00E+00 W-185 1.61E+06 4.02E+05 5.63E+04 0.00E+00 0.00E+00 0.00E+00 1.50E+07 0.00E+00 W-187 3.21E-02 1.90E-02 8.53E-03 0.00E+00 0.00E+00 0.00E+00 2.67E+00 0.00E+00 NP-239 4.26E-01 3.06E-02 2.15E-02 0.00E+00 8.85E-02 0.00E+00 2.26E+03 0.00E+00 U-232 6.11E+09 0.00E+00 4.37E+08 0.00E+00 4.65E+08 0.00E+00 2.42E+07 0.00E+00 U-233 1.29E+09 0.00E+00 7.82E+07 0.00E+00 2.12E+08 0.00E+00 2.24E+07 0.00E+00 U-234 1.24E+09 0.00E+00 7.68E+07 0.00E+00 2.08E+08 0.00E+00 2.20E+07 0.00E+00 U-235 1.19E+09 0.00E+00 7.19E+07 0.00E+00 1.95E+08 0.00E+00 2.79E+07 0.00E+00 U-236 1.19E+09 0.00E+00 7.37E+07 0.00E+00 1.99E+08 0.00E+00 2.06E+07 0.00E+00 U-237 3.41E+03 0.00E+00 9.07E+02 0.00E+00 9.85E+03 0.00E+00 3.01E+05 0.00E+00 U-238 1.14E+09 0.00E+00 6.74E+07 0.00E+00 1.82E+08 0.00E+00 1.97E+07 0.00E+00 NP-237 4.56E+08 3.01E+07 2.00E+07 0.00E+00 1.24E+08 0.00E+00 1.67E+07 0.00E+00 NP-238 2.23E+00 4.50E-02 3.47E-02 0.00E+00 1.44E-01 0.00E+00 1.54E+03 0.00E+00 PU-238 1.70E+07 1.97E+06 4.52E+05 0.00E+00 1.64E+06 0.00E+00 1.07E+06 0.00E+00 PU-239 1.85E+07 1.97E+06 4.74E+05 0.00E+00 1.75E+06 0.00E+00 9.80E+05 0.00E+00 PU-240 1.83E+07 2.05E+06 4.74E+05 0.00E+00 1.75E+06 0.00E+00 9.99E+05 0.00E+00 PU-241 5.51E+05 2.25E+04 1.14E+04 0.00E+00 4.21E+04 0.00E+00 2.05E+04 0.00E+00 PU-242 1.70E+07 1.97E+06 4.57E+05 0.00E+00 1.67E+06 0.00E+00 9.60E+05 0.00E+00 PU-244 1.99E+07 2.26E+07 5.22E+05 0.00E+00 1.93E+06 0.00E+00 1.43E+06 0.00E+00 AM-241 2.78E+08 2.39E+08 2.08E+07 0.00E+00 1.27E+08 0.00E+00 1.56E+07 0.00E+00 AM-242m 2.86E+08 2.29E+08 2.13E+07 0.00E+00 1.29E+08 0.00E+00 1.96E+07 0.00E+00 AM-243 2.74E+08 2.31E+08 2.01E+07 0.00E+00 1.24E+08 0.00E+00 1.83E+07 0.00E+00 CM-242 1.52E+07 1.21E+07 1.01E+06 0.00E+00 3.23E+06 0.00E+00 1.41E+07 0.00E+00 CM-243 2.61E+08 2.12E+08 1.68E+07 0.00E+00 6.28E+07 0.00E+00 1.64E+07 0.00E+00 CM-244 2.20E+08 1.78E+08 1.41E+07 0.00E+00 5.17E+07 0.00E+00 1.58E+07 0.00E+00 CM-245 3.41E+08 2.74E+08 2.15E+07 0.00E+00 8.40E+07 0.00E+00 1.48E+07 0.00E+00 CM-246 3.37E+08 2.74E+08 2.15E+07 0.00E+00 8.38E+07 0.00E+00 1.45E+07 0.00E+00 CM-247 3.29E+08 2.70E+08 2.11E+07 0.00E+00 8.26E+07 0.00E+00 1.91E+07 0.00E+00 CM-248 2.74E+09 2.23E+09 1.74E+08 0.00E+00 6.81E+08 0.00E+00 3.09E+08 0.00E+00 CF-252 2.09E+08 0.00E+00 5.05E+06 0.00E+00 0.00E+00 0.00E+00 5.88E+07 0.00E+00 II.4-174 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-43 (Page 1 of 4)
Teen Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 0.00E+00 C-14 2.81E+05 5.62E+04 5.62E+04 5.62E+04 5.62E+04 5.62E+04 5.62E+04 0.00E+00 NA-22 1.10E+09 1.10E+09 1.10E+09 1.10E+09 1.10E+09 1.10E+09 1.10E+09 0.00E+00 NA-24 1.08E-03 1.08E-03 1.08E-03 1.08E-03 1.08E-03 1.08E-03 1.08E-03 0.00E+00 P-32 3.93E+09 2.44E+08 1.53E+08 0.00E+00 0.00E+00 0.00E+00 3.31E+08 0.00E+00 CA-41 1.28E+09 0.00E+00 1.38E+08 0.00E+00 0.00E+00 0.00E+00 1.26E+06 0.00E+00 SC-46 1.36E+05 2.65E+05 7.87E+04 0.00E+00 2.54E+05 0.00E+00 9.04E+08 0.00E+00 CR-51 0.00E+00 0.00E+00 5.64E+03 3.13E+03 1.24E+03 8.05E+03 9.47E+05 0.00E+00 MN-54 0.00E+00 7.00E+06 1.39E+06 0.00E+00 2.09E+06 0.00E+00 1.44E+07 0.00E+00 FE-55 2.38E+08 1.69E+08 3.94E+07 0.00E+00 0.00E+00 1.07E+08 7.31E+07 0.00E+00 MN-56 0.00E+00 1.23E-53 2.19E-54 0.00E+00 1.56E-53 0.00E+00 8.10E-52 0.00E+00 CO-57 0.00E+00 4.53E+06 7.59E+06 0.00E+00 0.00E+00 0.00E+00 8.45E+07 0.00E+00 CO-58 0.00E+00 1.41E+07 3.24E+07 0.00E+00 0.00E+00 0.00E+00 1.94E+08 0.00E+00 FE-59 2.12E+08 4.95E+08 1.91E+08 0.00E+00 0.00E+00 1.56E+08 1.17E+09 0.00E+00 CO-60 0.00E+00 5.83E+07 1.31E+08 0.00E+00 0.00E+00 0.00E+00 7.60E+08 0.00E+00 NI-59 1.13E+08 4.00E+07 1.92E+07 0.00E+00 0.00E+00 0.00E+00 6.28E+06 0.00E+00 NI-63 1.52E+09 1.07E+08 5.15E+07 0.00E+00 0.00E+00 0.00E+00 1.71E+07 0.00E+00 CU-64 0.00E+00 2.21E-07 1.04E-07 0.00E+00 5.60E-07 0.00E+00 1.72E-05 0.00E+00 NI-65 1.88E-53 2.41E-54 1.10E-54 0.00E+00 0.00E+00 0.00E+00 1.30E-52 0.00E+00 ZN-65 2.50E+08 8.69E+08 4.05E+08 0.00E+00 5.56E+08 0.00E+00 3.68E+08 0.00E+00 ZN-69m 1.40E-05 3.30E-05 3.02E-06 0.00E+00 2.00E-05 0.00E+00 1.81E-03 0.00E+00 ZN-69 1.53E-153 2.91E-153 2.04E-154 0.00E+00 1.90E-153 0.00E+00 5.36E-153 0.00E+00 SE-79 0.00E+00 9.07E+07 1.52E+07 0.00E+00 1.58E+08 0.00E+00 1.39E+07 0.00E+00 BR-82 0.00E+00 0.00E+00 9.72E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-83 0.00E+00 0.00E+00 5.07E-57 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-84 0.00E+00 0.00E+00 5.42E-270 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BR-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 4.07E+08 1.91E+08 0.00E+00 0.00E+00 0.00E+00 6.02E+07 0.00E+00 RB-87 0.00E+00 8.79E+08 3.07E+08 0.00E+00 0.00E+00 0.00E+00 3.07E+07 0.00E+00 RB-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-89 2.55E+08 0.00E+00 7.29E+06 0.00E+00 0.00E+00 0.00E+00 3.03E+07 0.00E+00 SR-90 9.89E+09 0.00E+00 1.98E+08 0.00E+00 0.00E+00 0.00E+00 2.26E+08 0.00E+00 Y-90 9.06E+01 0.00E+00 2.44E+00 0.00E+00 0.00E+00 0.00E+00 7.47E+05 0.00E+00 SR-91 1.28E-10 0.00E+00 5.08E-12 0.00E+00 0.00E+00 0.00E+00 5.79E-10 0.00E+00 Y-91m 5.85E-175 0.00E+00 2.24E-176 0.00E+00 0.00E+00 0.00E+00 2.76E-173 0.00E+00 Y-91 9.54E+05 0.00E+00 2.56E+04 0.00E+00 0.00E+00 0.00E+00 3.91E+08 0.00E+00 II.4-175 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-43 (Page 2 of 4)
Teen Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 9.88E-50 0.00E+00 4.21E-51 0.00E+00 0.00E+00 0.00E+00 2.52E-48 0.00E+00 Y-92 1.28E-39 0.00E+00 3.71E-41 0.00E+00 0.00E+00 0.00E+00 3.52E-35 0.00E+00 Y-93 3.96E-12 0.00E+00 1.09E-13 0.00E+00 0.00E+00 0.00E+00 1.21E-07 0.00E+00 NB-93m 1.55E+07 5.10E+06 1.28E+06 0.00E+00 5.96E+06 0.00E+00 1.84E+09 0.00E+00 NB-95 1.79E+06 9.95E+05 5.48E+05 0.00E+00 9.65E+05 0.00E+00 4.26E+09 0.00E+00 NB-97 4.92E-119 1.22E-119 4.46E-120 0.00E+00 1.43E-119 0.00E+00 2.92E-115 0.00E+00 ZR-93 3.05E+06 1.50E+06 8.21E+05 0.00E+00 5.32E+06 0.00E+00 1.42E+09 0.00E+00 ZR-95 1.50E+06 4.73E+05 3.25E+05 0.00E+00 6.95E+05 0.00E+00 1.09E+09 0.00E+00 ZR-97 1.72E-05 3.41E-06 1.57E-06 0.00E+00 5.17E-06 0.00E+00 9.23E-01 0.00E+00 MO-93 0.00E+00 1.37E+08 3.76E+06 0.00E+00 3.94E+07 0.00E+00 1.67E+07 0.00E+00 MO-99 0.00E+00 8.27E+04 1.58E+04 0.00E+00 1.89E+05 0.00E+00 1.48E+05 0.00E+00 TC-99 1.16E+08 1.70E+08 4.65E+07 0.00E+00 2.17E+09 1.76E+07 4.17E+09 0.00E+00 TC-99m 3.53E-21 9.86E-21 1.28E-19 0.00E+00 1.47E-19 5.47E-21 6.47E-18 0.00E+00 TC-101 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-103 8.57E+07 0.00E+00 3.66E+07 0.00E+00 3.02E+08 0.00E+00 7.16E+09 0.00E+00 RU-105 4.83E-28 0.00E+00 1.87E-28 0.00E+00 6.09E-27 0.00E+00 3.90E-25 0.00E+00 RU-106 2.36E+09 0.00E+00 2.97E+08 0.00E+00 4.55E+09 0.00E+00 1.13E+11 0.00E+00 RH-105 3.25E+00 2.35E+00 1.54E+00 0.00E+00 9.96E+00 0.00E+00 2.98E+02 0.00E+00 PD-107 0.00E+00 1.35E+06 8.69E+04 0.00E+00 1.22E+07 0.00E+00 6.26E+06 0.00E+00 PD-109 0.00E+00 1.11E-06 2.51E-07 0.00E+00 6.39E-06 0.00E+00 1.11E-04 0.00E+00 AG-110m 5.06E+06 4.79E+06 2.91E+06 0.00E+00 9.13E+06 0.00E+00 1.34E+09 0.00E+00 AG-111 1.24E+05 5.13E+04 2.58E+04 0.00E+00 1.67E+05 0.00E+00 7.15E+07 0.00E+00 CD-113m 0.00E+00 3.85E+06 1.24E+05 0.00E+00 4.26E+06 0.00E+00 2.31E+07 0.00E+00 CD-115m 0.00E+00 1.25E+06 4.02E+04 0.00E+00 9.96E+05 0.00E+00 3.94E+07 0.00E+00 SN-123 4.66E+09 7.66E+07 1.13E+08 6.14E+07 0.00E+00 0.00E+00 7.05E+09 0.00E+00 SN-125 1.49E+08 2.97E+06 6.73E+06 2.33E+06 0.00E+00 0.00E+00 1.40E+09 0.00E+00 SN-126 1.50E+10 2.80E+08 4.28E+08 7.38E+07 0.00E+00 0.00E+00 3.34E+09 0.00E+00 SB-124 1.62E+07 2.98E+05 6.31E+06 3.67E+04 0.00E+00 1.41E+07 3.26E+08 0.00E+00 SB-125 1.56E+07 1.71E+05 3.66E+06 1.49E+04 0.00E+00 1.37E+07 1.22E+08 0.00E+00 SB-126 1.58E+06 3.23E+04 5.68E+05 8.94E+03 0.00E+00 1.13E+06 9.35E+07 0.00E+00 SB-127 1.38E+04 2.95E+02 5.21E+03 1.55E+02 0.00E+00 9.39E+03 2.34E+06 0.00E+00 TE-125m 3.03E+08 1.09E+08 4.05E+07 8.47E+07 0.00E+00 0.00E+00 8.94E+08 0.00E+00 TE-127m 9.41E+08 3.34E+08 1.12E+08 2.24E+08 3.82E+09 0.00E+00 2.35E+09 0.00E+00 TE-127 1.80E-10 6.38E-11 3.88E-11 1.24E-10 7.29E-10 0.00E+00 1.39E-08 0.00E+00 TE-129m 9.50E+08 3.53E+08 1.50E+08 3.07E+08 3.97E+09 0.00E+00 3.57E+09 0.00E+00 TE-129 3.76E-121 1.40E-121 9.16E-122 2.69E-121 1.58E-120 0.00E+00 2.06E-120 0.00E+00 TE-133m 4.67E-153 2.66E-153 2.58E-153 3.71E-153 2.63E-152 0.00E+00 1.07E-152 0.00E+00 II.4-176 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-43 (Page 3 of 4)
Teen Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 2.59E-204 1.67E-204 1.74E-204 2.13E-204 1.59E-203 0.00E+00 9.63E-206 0.00E+00 I-129 1.10E+08 9.21E+07 1.54E+08 1.12E+11 1.65E+08 0.00E+00 1.07E+07 0.00E+00 I-130 1.70E-06 4.91E-06 1.96E-06 4.00E-04 7.56E-06 0.00E+00 3.77E-06 0.00E+00 I-131 8.92E+06 1.25E+07 6.71E+06 3.65E+09 2.15E+07 0.00E+00 2.47E+06 0.00E+00 TE-131m 3.76E+02 1.80E+02 1.50E+02 2.71E+02 1.88E+03 0.00E+00 1.45E+04 0.00E+00 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-132 5.66E-59 1.48E-58 5.31E-59 4.99E-57 2.33E-58 0.00E+00 6.45E-59 0.00E+00 TE-132 1.16E+06 7.36E+05 6.92E+05 7.76E+05 7.06E+06 0.00E+00 2.33E+07 0.00E+00 I-133 3.05E-01 5.18E-01 1.58E-01 7.23E+01 9.09E-01 0.00E+00 3.92E-01 0.00E+00 CS-134m 2.13E-47 4.42E-47 2.27E-47 0.00E+00 2.46E-47 4.32E-48 2.94E-47 0.00E+00 CS-134 5.23E+08 1.23E+09 5.71E+08 0.00E+00 3.91E+08 1.49E+08 1.53E+07 0.00E+00 I-134 8.66E-162 2.30E-161 8.24E-162 3.83E-160 3.62E-161 0.00E+00 3.02E-163 0.00E+00 I-135 3.60E-17 9.27E-17 3.44E-17 5.96E-15 1.46E-16 0.00E+00 1.03E-16 0.00E+00 CS-135 1.80E+08 1.65E+08 3.86E+07 0.00E+00 6.31E+07 2.28E+07 2.89E+06 0.00E+00 CS-136 9.40E+06 3.70E+07 2.48E+07 0.00E+00 2.01E+07 3.17E+06 2.98E+06 0.00E+00 CS-137 7.24E+08 9.63E+08 3.36E+08 0.00E+00 3.28E+08 1.27E+08 1.37E+07 0.00E+00 CS-138 2.23E-267 4.28E-267 2.14E-267 0.00E+00 3.16E-267 3.68E-268 1.94E-270 0.00E+00 CS-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-139 1.05E-101 7.41E-105 3.07E-103 0.00E+00 6.98E-105 5.10E-105 9.39E-101 0.00E+00 BA-140 2.38E+07 2.91E+04 1.53E+06 0.00E+00 9.87E+03 1.96E+04 3.66E+07 0.00E+00 LA-140 3.05E-02 1.50E-02 3.99E-03 0.00E+00 0.00E+00 0.00E+00 8.61E+02 0.00E+00 BA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-141 3.29E-37 1.01E-37 1.67E-38 0.00E+00 0.00E+00 0.00E+00 1.79E-32 0.00E+00 CE-141 1.18E+04 7.87E+03 9.04E+02 0.00E+00 3.71E+03 0.00E+00 2.25E+07 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-142 2.85E-92 1.26E-92 3.15E-93 0.00E+00 0.00E+00 0.00E+00 3.85E-88 0.00E+00 CE-143 1.69E-02 1.23E+01 1.37E-03 0.00E+00 5.51E-03 0.00E+00 3.69E+02 0.00E+00 PR-143 1.76E+04 7.04E+03 8.78E+02 0.00E+00 4.09E+03 0.00E+00 5.80E+07 0.00E+00 CE-144 1.23E+06 5.08E+05 6.60E+04 0.00E+00 3.04E+05 0.00E+00 3.09E+08 0.00E+00 PR-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND-147 6.23E+03 6.77E+03 4.06E+02 0.00E+00 3.98E+03 0.00E+00 2.44E+07 0.00E+00 PM-147 7.93E+05 7.53E+04 3.07E+04 0.00E+00 1.44E+05 0.00E+00 7.16E+07 0.00E+00 PM-148m 1.72E+05 4.36E+04 3.41E+04 0.00E+00 6.60E+04 0.00E+00 2.74E+08 0.00E+00 PM-148 1.66E+03 2.70E+02 1.36E+02 0.00E+00 4.88E+02 0.00E+00 1.61E+07 0.00E+00 PM-149 4.33E+00 6.09E-01 2.50E-01 0.00E+00 1.16E+00 0.00E+00 8.97E+04 0.00E+00 PM-151 4.82E-03 7.96E-04 4.03E-04 0.00E+00 1.43E-03 0.00E+00 1.79E+02 0.00E+00 SM-151 7.07E+05 1.36E+05 3.19E+04 0.00E+00 1.49E+05 0.00E+00 4.61E+07 0.00E+00 II.4-177 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-43 (Page 4 of 4)
Teen Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 9.63E-01 7.97E-01 5.87E-02 0.00E+00 2.61E-01 0.00E+00 2.25E+04 0.00E+00 EU-152 1.90E+06 4.56E+05 4.02E+05 0.00E+00 2.12E+06 0.00E+00 1.68E+08 0.00E+00 EU-154 6.10E+06 7.87E+05 5.54E+05 0.00E+00 3.52E+06 0.00E+00 4.16E+08 0.00E+00 EU-155 1.33E+06 1.29E+05 7.97E+04 0.00E+00 5.03E+05 0.00E+00 7.38E+08 0.00E+00 EU-156 3.12E+04 2.34E+04 3.81E+03 0.00E+00 1.57E+04 0.00E+00 1.19E+08 0.00E+00 TB-160 3.19E+05 0.00E+00 3.98E+04 0.00E+00 1.26E+05 0.00E+00 2.07E+08 0.00E+00 HO-166m 2.55E+06 7.84E+05 5.68E+05 0.00E+00 1.15E+06 0.00E+00 7.13E-12 0.00E+00 W-181 2.39E+04 7.71E+03 8.06E+02 0.00E+00 0.00E+00 0.00E+00 6.57E+05 0.00E+00 W-185 8.55E+05 2.82E+05 2.98E+04 0.00E+00 0.00E+00 0.00E+00 2.44E+07 0.00E+00 W-187 1.73E-02 1.41E-02 4.95E-03 0.00E+00 0.00E+00 0.00E+00 3.82E+00 0.00E+00 NP-239 2.26E-01 2.14E-02 1.19E-02 0.00E+00 6.70E-02 0.00E+00 3.44E+03 0.00E+00 U-232 3.24E+09 0.00E+00 2.32E+08 0.00E+00 3.51E+08 0.00E+00 3.96E+07 0.00E+00 U-233 6.83E+08 0.00E+00 4.15E+07 0.00E+00 1.60E+08 0.00E+00 3.66E+07 0.00E+00 U-234 6.56E+08 0.00E+00 4.07E+07 0.00E+00 1.57E+08 0.00E+00 3.59E+07 0.00E+00 U-235 6.28E+08 0.00E+00 3.82E+07 0.00E+00 1.47E+08 0.00E+00 4.56E+07 0.00E+00 U-236 6.28E+08 0.00E+00 3.91E+07 0.00E+00 1.50E+08 0.00E+00 3.37E+07 0.00E+00 U-237 1.81E+03 0.00E+00 4.82E+02 0.00E+00 7.43E+03 0.00E+00 4.79E+05 0.00E+00 U-238 6.01E+08 0.00E+00 3.58E+07 0.00E+00 1.38E+08 0.00E+00 3.21E+07 0.00E+00 NP-237 4.31E+08 3.10E+07 1.90E+07 0.00E+00 1.40E+08 0.00E+00 2.73E+07 0.00E+00 NP-238 1.18E+00 3.16E-02 1.84E-02 0.00E+00 1.08E-01 0.00E+00 2.32E+03 0.00E+00 PU-238 1.52E+07 1.94E+06 4.13E+05 0.00E+00 1.77E+06 0.00E+00 1.75E+06 0.00E+00 PU-239 1.74E+07 2.11E+06 4.56E+05 0.00E+00 1.94E+06 0.00E+00 1.60E+06 0.00E+00 PU-240 1.73E+07 2.10E+06 4.56E+05 0.00E+00 1.94E+06 0.00E+00 1.63E+06 0.00E+00 PU-241 3.95E+05 1.90E+04 8.33E+03 0.00E+00 3.86E+04 0.00E+00 3.34E+04 0.00E+00 PU-242 1.61E+07 2.03E+06 4.40E+05 0.00E+00 1.87E+06 0.00E+00 1.57E+06 0.00E+00 PU-244 1.88E+07 2.31E+06 5.04E+05 0.00E+00 2.14E+06 0.00E+00 2.34E+06 0.00E+00 AM-241 2.59E+08 2.44E+08 1.86E+07 0.00E+00 1.40E+08 0.00E+00 2.55E+07 0.00E+00 AM-242m 2.61E+08 2.30E+08 1.88E+07 0.00E+00 1.39E+08 0.00E+00 3.21E+07 0.00E+00 AM-243 2.58E+08 2.38E+08 1.82E+07 0.00E+00 1.37E+08 0.00E+00 2.99E+07 0.00E+00 CM-242 8.06E+06 8.50E+06 5.35E+05 0.00E+00 2.44E+06 0.00E+00 2.30E+07 0.00E+00 CM-243 2.10E+08 1.95E+08 1.32E+07 0.00E+00 6.17E+07 0.00E+00 2.68E+07 0.00E+00 CM-244 1.63E+08 1.54E+08 1.03E+07 0.00E+00 4.81E+07 0.00E+00 2.58E+07 0.00E+00 CM-245 3.21E+08 2.82E+08 1.98E+07 0.00E+00 9.24E+07 0.00E+00 2.42E+07 0.00E+00 CM-246 3.18E+08 2.82E+08 1.97E+07 0.00E+00 9.20E+07 0.00E+00 2.38E+07 0.00E+00 CM-247 3.10E+08 2.78E+08 1.94E+07 0.00E+00 9.08E+07 0.00E+00 3.12E+07 0.00E+00 CM-248 2.58E+09 2.29E+09 1.60E+08 0.00E+00 7.49E+08 0.00E+00 5.02E+08 0.00E+00 CF-252 1.09E+08 0.00E+00 2.64E+06 0.00E+00 0.00E+00 0.00E+00 9.60E+07 0.00E+00 II.4-178 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-44 (Page 1 of 4)
Adult Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin H-3 0.00E+00 1.85E+02 1.85E+02 1.85E+02 1.85E+02 1.85E+02 1.85E+02 0.00E+00 C-14 3.33E+05 6.66E+04 6.66E+04 6.66E+04 6.66E+04 6.66E+04 6.66E+04 0.00E+00 NA-22 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 0.00E+00 NA-24 1.36E-03 1.36E-03 1.36E-03 1.36E-03 1.36E-03 1.36E-03 1.36E-03 0.00E+00 P-32 4.66E+09 2.90E+08 1.80E+08 0.00E+00 0.00E+00 0.00E+00 5.24E+08 0.00E+00 CA-41 2.03E+09 0.00E+00 2.19E+08 0.00E+00 0.00E+00 0.00E+00 2.02E+06 0.00E+00 SC-46 1.76E+05 3.41E+05 9.91E+04 0.00E+00 3.18E+05 0.00E+00 1.66E+09 0.00E+00 CR-51 0.00E+00 0.00E+00 7.05E+03 4.21E+03 1.55E+03 9.35E+03 1.77E+06 0.00E+00 MN-54 0.00E+00 9.18E+06 1.75E+06 0.00E+00 2.73E+06 0.00E+00 2.81E+07 0.00E+00 FE-55 2.93E+08 2.03E+08 4.72E+07 0.00E+00 0.00E+00 1.13E+08 1.16E+08 0.00E+00 MN-56 0.00E+00 1.52E-53 2.69E-54 0.00E+00 1.92E-53 0.00E+00 4.84E-52 0.00E+00 CO-57 0.00E+00 5.64E+06 9.37E+06 0.00E+00 0.00E+00 0.00E+00 1.43E+08 0.00E+00 CO-58 0.00E+00 1.82E+07 4.09E+07 0.00E+00 0.00E+00 0.00E+00 3.69E+08 0.00E+00 FE-59 2.66E+08 6.24E+08 2.39E+08 0.00E+00 0.00E+00 1.74E+08 2.08E+09 0.00E+00 CO-60 0.00E+00 7.52E+07 1.66E+08 0.00E+00 0.00E+00 0.00E+00 1.41E+09 0.00E+00 NI-59 1.42E+08 4.87E+07 2.37E+07 0.00E+00 0.00E+00 0.00E+00 1.00E+07 0.00E+00 NI-63 1.89E+09 1.31E+08 6.33E+07 0.00E+00 0.00E+00 0.00E+00 2.73E+07 0.00E+00 CU-64 0.00E+00 2.71E-07 1.27E-07 0.00E+00 6.84E-07 0.00E+00 2.31E-05 0.00E+00 NI-65 2.25E-53 2.92E-54 1.33E-54 0.00E+00 0.00E+00 0.00E+00 7.40E-53 0.00E+00 ZN-65 3.56E+08 1.13E+09 5.12E+08 0.00E+00 7.57E+08 0.00E+00 7.13E+08 0.00E+00 ZN-69m 1.68E-05 4.02E-05 3.68E-06 0.00E+00 2.43E-05 0.00E+00 2.45E-03 0.00E+00 ZN-69 1.81E-153 3.46E-153 2.41E-154 0.00E+00 2.25E-153 0.00E+00 5.20E-154 0.00E+00 SE-79 0.00E+00 1.08E+08 1.81E+07 0.00E+00 1.87E+08 0.00E+00 2.21E+07 0.00E+00 BR-82 0.00E+00 0.00E+00 1.22E+03 0.00E+00 0.00E+00 0.00E+00 1.40E+03 0.00E+00 BR-83 0.00E+00 0.00E+00 6.00E-57 0.00E+00 0.00E+00 0.00E+00 8.65E-57 0.00E+00 BR-84 0.00E+00 0.00E+00 6.62E-270 0.00E+00 0.00E+00 0.00E+00 5.19E-275 0.00E+00 BR-85 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-86 0.00E+00 4.87E+08 2.27E+08 0.00E+00 0.00E+00 0.00E+00 9.60E+07 0.00E+00 RB-87 0.00E+00 1.05E+09 3.64E+08 0.00E+00 0.00E+00 0.00E+00 4.90E+07 0.00E+00 RB-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RB-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SR-89 3.02E+08 0.00E+00 8.66E+06 0.00E+00 0.00E+00 0.00E+00 4.84E+07 0.00E+00 SR-90 1.43E+10 0.00E+00 2.87E+08 0.00E+00 0.00E+00 0.00E+00 3.59E+08 0.00E+00 Y-90 1.08E+02 0.00E+00 2.89E+00 0.00E+00 0.00E+00 0.00E+00 1.14E+06 0.00E+00 SR-91 1.52E-10 0.00E+00 6.14E-12 0.00E+00 0.00E+00 0.00E+00 7.23E-10 0.00E+00 Y-91m 6.98E-175 0.00E+00 2.70E-176 0.00E+00 0.00E+00 0.00E+00 2.05E-174 0.00E+00 Y-91 1.13E+06 0.00E+00 3.03E+04 0.00E+00 0.00E+00 0.00E+00 6.23E+08 0.00E+00 II.4-179 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-44 (Page 2 of 4)
Adult Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SR-92 1.18E-49 0.00E+00 5.10E-51 0.00E+00 0.00E+00 0.00E+00 2.33E-48 0.00E+00 Y-92 1.52E-39 0.00E+00 4.43E-41 0.00E+00 0.00E+00 0.00E+00 2.66E-35 0.00E+00 Y-93 4.69E-12 0.00E+00 1.30E-13 0.00E+00 0.00E+00 0.00E+00 1.49E-07 0.00E+00 NB-93m 1.95E+07 6.36E+06 1.57E+06 0.00E+00 7.31E+06 0.00E+00 2.93E+09 0.00E+00 NB-95 2.30E+06 1.28E+06 6.87E+05 0.00E+00 1.26E+06 0.00E+00 7.76E+09 0.00E+00 NB-97 5.90E-119 1.49E-119 5.45E-120 0.00E+00 1.74E-119 0.00E+00 5.50E-116 0.00E+00 ZR-93 3.90E+06 2.18E+05 1.02E+05 0.00E+00 8.27E+05 0.00E+00 2.27E+08 0.00E+00 ZR-95 1.87E+06 6.01E+05 4.07E+05 0.00E+00 9.42E+05 0.00E+00 1.90E+09 0.00E+00 ZR-97 2.07E-05 4.17E-06 1.91E-06 0.00E+00 6.30E-06 0.00E+00 1.29E+00 0.00E+00 MO-93 0.00E+00 1.65E+08 4.45E+06 0.00E+00 4.67E+07 0.00E+00 2.68E+07 0.00E+00 MO-99 0.00E+00 1.00E+05 1.90E+04 0.00E+00 2.26E+05 0.00E+00 2.32E+05 0.00E+00 TC-99 1.37E+08 2.04E+08 5.51E+07 0.00E+00 2.57E+09 1.73E+07 6.67E+09 0.00E+00 TC-99m 4.45E-21 1.26E-20 1.60E-19 0.00E+00 1.91E-19 6.16E-21 7.44E-18 0.00E+00 TC-101 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 RU-103 1.05E+08 0.00E+00 4.53E+07 0.00E+00 4.01E+08 0.00E+00 1.23E+10 0.00E+00 RU-105 5.78E-28 0.00E+00 2.28E-28 0.00E+00 7.46E-27 0.00E+00 3.53E-25 0.00E+00 RU-106 2.80E+09 0.00E+00 3.54E+08 0.00E+00 5.40E+09 0.00E+00 1.81E+11 0.00E+00 RH-105 3.84E+00 2.81E+00 1.85E+00 0.00E+00 1.19E+01 0.00E+00 4.48E+02 0.00E+00 PD-107 0.00E+00 1.61E+06 1.03E+05 0.00E+00 1.45E+07 0.00E+00 9.99E+06 0.00E+00 PD-109 0.00E+00 1.32E-06 2.97E-07 0.00E+00 7.53E-06 0.00E+00 1.46E-04 0.00E+00 AG-110m 6.68E+06 6.18E+06 3.67E+06 0.00E+00 1.22E+07 0.00E+00 2.52E+09 0.00E+00 AG-111 1.47E+05 6.13E+04 3.05E+04 0.00E+00 1.98E+05 0.00E+00 1.12E+08 0.00E+00 CD-113m 0.00E+00 4.60E+06 1.47E+05 0.00E+00 5.06E+06 0.00E+00 3.70E+07 0.00E+00 CD-115m 0.00E+00 1.49E+06 4.76E+04 0.00E+00 1.18E+06 0.00E+00 6.27E+07 0.00E+00 SN-123 5.53E+09 9.16E+07 1.35E+08 7.79E+07 0.00E+00 0.00E+00 1.13E+10 0.00E+00 SN-125 1.77E+08 3.56E+06 8.01E+06 2.95E+06 0.00E+00 0.00E+00 2.21E+09 0.00E+00 SN-126 1.85E+10 3.66E+08 5.27E+08 1.08E+08 0.00E+00 0.00E+00 5.33E+09 0.00E+00 SB-124 1.98E+07 3.74E+05 7.84E+06 4.80E+04 0.00E+00 1.54E+07 5.62E+08 0.00E+00 SB-125 1.91E+07 2.13E+05 4.55E+06 1.94E+04 0.00E+00 1.47E+07 2.10E+08 0.00E+00 SB-126 1.93E+06 3.94E+04 6.98E+05 1.18E+04 0.00E+00 1.19E+06 1.58E+08 0.00E+00 SB-127 1.66E+04 3.63E+02 6.37E+03 1.99E+02 0.00E+00 9.84E+03 3.80E+06 0.00E+00 TE-125m 3.59E+08 1.30E+08 4.81E+07 1.08E+08 1.46E+09 0.00E+00 1.43E+09 0.00E+00 TE-127m 1.12E+09 3.99E+08 1.36E+08 2.85E+08 4.53E+09 0.00E+00 3.74E+09 0.00E+00 TE-127 2.12E-10 7.62E-11 4.59E-11 1.57E-10 8.64E-10 0.00E+00 1.67E-08 0.00E+00 TE-129m 1.13E+09 4.23E+08 1.79E+08 3.90E+08 4.73E+09 0.00E+00 5.71E+09 0.00E+00 TE-129 4.47E-121 1.68E-121 1.09E-121 3.43E-121 1.88E-120 0.00E+00 3.37E-121 0.00E+00 TE-133m 5.67E-153 3.32E-153 3.19E-153 4.80E-153 3.28E-152 0.00E+00 1.14E-153 0.00E+00 II.4-180 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-44 (Page 3 of 4)
Adult Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin TE-134 3.18E-204 2.08E-204 1.28E-204 2.78E-204 2.01E-203 0.00E+00 3.53E-207 0.00E+00 I-129 1.30E+08 1.12E+08 3.66E+08 2.88E+11 2.40E+08 0.00E+00 1.77E+07 0.00E+00 I-130 2.11E-06 6.22E-06 2.45E-06 5.27E-04 9.71E-06 0.00E+00 5.35E-06 0.00E+00 I-131 1.07E+07 1.54E+07 8.80E+06 5.03E+09 2.63E+07 0.00E+00 4.05E+06 0.00E+00 TE-131m 4.51E+02 2.21E+02 1.84E+02 3.49E+02 2.23E+03 0.00E+00 2.19E+04 0.00E+00 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-132 6.97E-59 1.86E-58 6.52E-59 6.52E-57 2.97E-58 0.00E+00 3.50E-59 0.00E+00 TE-132 1.42E+06 9.18E+05 8.62E+05 1.01E+06 8.84E+06 0.00E+00 4.34E+07 0.00E+00 I-133 3.65E-01 6.35E-01 1.94E-01 9.34E+01 1.11E+00 0.00E+00 5.71E-01 0.00E+00 CS-134m 2.62E-47 5.50E-47 2.81E-47 0.00E+00 2.98E-47 4.70E-48 1.94E-47 0.00E+00 CS-134 6.58E+08 1.56E+09 1.28E+09 0.00E+00 5.06E+08 1.68E+08 2.74E+07 0.00E+00 I-134 1.06E-161 2.89E-161 1.03E-161 5.01E-160 4.60E-161 0.00E+00 2.52E-164 0.00E+00 I-135 4.43E-17 1.16E-16 4.28E-17 7.64E-15 1.86E-16 0.00E+00 1.31E-16 0.00E+00 CS-135 2.14E+08 1.97E+08 8.76E+07 0.00E+00 7.47E+07 2.24E+07 4.62E+06 0.00E+00 CS-136 1.21E+07 4.76E+07 3.43E+07 0.00E+00 2.65E+07 3.63E+06 5.41E+06 0.00E+00 CS-137 8.72E+08 1.19E+09 7.81E+08 0.00E+00 4.05E+08 1.35E+08 2.31E+07 0.00E+00 CS-138 2.68E-267 5.30E-267 2.63E-267 0.00E+00 3.90E-267 3.85E-268 2.26E-272 0.00E+00 CS-139 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BA-139 1.24E-101 8.86E-105 3.64E-103 0.00E+00 8.28E-105 5.02E-105 2.20E-101 0.00E+00 BA-140 2.87E+07 3.61E+04 1.88E+06 0.00E+00 1.23E+04 2.07E+04 5.92E+07 0.00E+00 LA-140 3.71E-02 1.87E-02 4.94E-03 0.00E+00 0.00E+00 0.00E+00 1.37E+03 0.00E+00 BA-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-141 3.90E-37 1.21E-37 1.98E-38 0.00E+00 0.00E+00 0.00E+00 1.44E-32 0.00E+00 CE-141 1.40E+04 9.50E+03 1.08E+03 0.00E+00 4.41E+03 0.00E+00 3.63E+07 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LA-142 3.45E-92 1.57E-92 3.90E-93 0.00E+00 0.00E+00 0.00E+00 1.14E-88 0.00E+00 CE-143 2.01E-02 1.48E+01 1.64E-03 0.00E+00 6.53E-03 0.00E+00 5.55E+02 0.00E+00 PR-143 2.10E+04 8.41E+03 1.04E+03 0.00E+00 4.85E+03 0.00E+00 9.18E+07 0.00E+00 CE-144 1.46E+06 6.09E+05 7.83E+04 0.00E+00 3.61E+05 0.00E+00 4.93E+08 0.00E+00 PR-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND-147 7.07E+03 8.17E+03 4.89E+02 0.00E+00 4.78E+03 0.00E+00 3.92E+07 0.00E+00 PM-147 9.64E+05 9.07E+04 3.67E+04 0.00E+00 1.71E+05 0.00E+00 1.14E+08 0.00E+00 PM-148m 2.16E+05 5.58E+04 4.27E+04 0.00E+00 8.43E+04 0.00E+00 4.73E+08 0.00E+00 PM-148 1.97E+03 3.28E+02 1.65E+02 0.00E+00 6.19E+02 0.00E+00 2.57E+07 0.00E+00 PM-149 5.14E+00 7.27E-01 2.97E-01 0.00E+00 1.37E+00 0.00E+00 1.36E+05 0.00E+00 PM-151 5.76E-03 9.67E-04 4.89E-04 0.00E+00 1.73E-03 0.00E+00 2.66E+02 0.00E+00 SM-151 9.45E+05 1.63E+05 3.90E+04 0.00E+00 1.82E+05 0.00E+00 7.19E+07 0.00E+00 II.4-181 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 4-44 (Page 4 of 4)
Adult Meat Ri m2*mrem*sec/yr*µCi Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LLI Skin SM-153 1.15E+00 9.55E-01 6.97E-02 0.00E+00 3.09E-01 0.00E+00 3.41E+04 0.00E+00 EU-152 2.55E+06 5.81E+05 5.11E+05 0.00E+00 3.60E+06 0.00E+00 3.35E+08 0.00E+00 EU-154 8.03E+06 9.87E+05 7.02E+05 0.00E+00 4.72E+06 0.00E+00 7.15E+08 0.00E+00 EU-155 1.11E+06 1.58E+05 1.02E+05 0.00E+00 7.30E+05 0.00E+00 1.24E+08 0.00E+00 EU-156 3.76E+04 2.91E+04 4.70E+03 0.00E+00 1.94E+04 0.00E+00 1.99E+08 0.00E+00 TB-160 3.92E+05 0.00E+00 4.89E+04 0.00E+00 1.62E+05 0.00E+00 2.14E+08 0.00E+00 HO-166m 3.26E+06 1.02E+06 7.72E+05 0.00E+00 1.52E+06 0.00E+00 1.21E-11 0.00E+00 W-181 2.82E+04 9.20E+03 9.86E+02 0.00E+00 0.00E+00 0.00E+00 1.05E+06 0.00E+00 W-185 1.01E+06 3.37E+05 3.55E+04 0.00E+00 0.00E+00 0.00E+00 3.90E+07 0.00E+00 W-187 2.07E-02 1.73E-02 6.04E-03 0.00E+00 0.00E+00 0.00E+00 5.66E+00 0.00E+00 NP-239 2.59E-01 2.55E-02 1.40E-02 0.00E+00 7.95E-02 0.00E+00 5.23E+03 0.00E+00 U-232 3.85E+09 0.00E+00 2.75E+08 0.00E+00 4.16E+08 0.00E+00 6.32E+07 0.00E+00 U-233 8.12E+08 0.00E+00 4.92E+07 0.00E+00 1.89E+08 0.00E+00 5.85E+07 0.00E+00 U-234 7.80E+08 0.00E+00 4.82E+07 0.00E+00 1.86E+08 0.00E+00 5.73E+07 0.00E+00 U-235 7.47E+08 0.00E+00 4.53E+07 0.00E+00 1.74E+08 0.00E+00 7.28E+07 0.00E+00 U-236 7.47E+08 0.00E+00 4.62E+07 0.00E+00 1.78E+08 0.00E+00 5.37E+07 0.00E+00 U-237 2.14E+03 0.00E+00 5.70E+02 0.00E+00 8.81E+03 0.00E+00 7.53E+05 0.00E+00 U-238 7.15E+08 0.00E+00 4.23E+07 0.00E+00 1.63E+08 0.00E+00 5.13E+07 0.00E+00 NP-237 6.91E+08 4.91E+07 3.04E+07 0.00E+00 2.26E+08 0.00E+00 4.36E+07 0.00E+00 NP-238 1.40E+00 3.78E-02 2.18E-02 0.00E+00 1.28E-01 0.00E+00 3.51E+03 0.00E+00 PU-238 2.42E+07 3.06E+06 6.56E+05 0.00E+00 2.81E+06 0.00E+00 2.80E+06 0.00E+00 PU-239 2.78E+07 3.34E+06 7.33E+05 0.00E+00 3.11E+06 0.00E+00 2.56E+06 0.00E+00 PU-240 2.78E+07 3.34E+06 7.33E+05 0.00E+00 3.11E+06 0.00E+00 2.60E+06 0.00E+00 PU-241 6.00E+05 2.85E+04 1.27E+04 0.00E+00 5.84E+04 0.00E+00 5.35E+04 0.00E+00 PU-242 2.58E+07 3.22E+06 7.06E+05 0.00E+00 3.00E+06 0.00E+00 2.51E+06 0.00E+00 PU-244 3.01E+07 3.69E+06 8.10E+05 0.00E+00 3.44E+06 0.00E+00 3.74E+06 0.00E+00 AM-241 4.14E+08 3.87E+08 2.97E+07 0.00E+00 2.23E+08 0.00E+00 4.07E+07 0.00E+00 AM-242m 4.17E+08 3.63E+08 2.98E+07 0.00E+00 2.22E+08 0.00E+00 5.12E+07 0.00E+00 AM-243 4.14E+08 3.78E+08 2.91E+07 0.00E+00 2.19E+08 0.00E+00 4.77E+07 0.00E+00 CM-242 9.56E+06 1.02E+07 6.36E+05 0.00E+00 2.89E+06 0.00E+00 3.67E+07 0.00E+00 CM-243 3.28E+08 3.00E+08 2.05E+07 0.00E+00 9.57E+07 0.00E+00 4.27E+07 0.00E+00 CM-244 2.49E+08 2.33E+08 1.57E+07 0.00E+00 7.32E+07 0.00E+00 4.12E+07 0.00E+00 CM-245 5.14E+08 4.48E+08 3.16E+07 0.00E+00 1.48E+08 0.00E+00 3.86E+07 0.00E+00 CM-246 5.10E+08 4.48E+08 3.15E+07 0.00E+00 1.47E+08 0.00E+00 3.79E+07 0.00E+00 CM-247 4.97E+08 4.41E+08 3.11E+07 0.00E+00 1.45E+08 0.00E+00 4.99E+07 0.00E+00 CM-248 4.14E+09 3.64E+09 2.56E+08 0.00E+00 1.20E+09 0.00E+00 8.06E+08 0.00E+00 CF-252 1.39E+08 0.00E+00 3.35E+06 0.00E+00 0.00E+00 0.00E+00 1.53E+08 0.00E+00 II.4-182 LASALLE ODCM PART II SECTION 4.doc
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual 5.0 TOTAL DOSE Radioactivity contained within tanks, pipes or other systems and contained radioactive material or waste stored on site can produce radiation at offsite locations. Annual offsite radiation doses near the station due to such sources were judged to be negligible in comparison with applicable limits except for doses due to BWR turbine skyshine, Independent Spent Fuel Storage Installations (ISFSI), and potential doses due to radioactive waste storage facilities (excludes radioactive material storage). Changes or modifications to the power station that may impact the offsite dose through increases to the direct radiation levels need to be evaluated on a case-by-case basis and added to the Radiological Effluent Controls (RECS) to the ODCM when applicable.
5.1 Total Dose Calculation Requirements 5.1.1 Total Effective Dose Equivalent Limits; 10CFR20 and 40CFR190 LaSalle Station is required to determine the total dose to a member of the public due to all uranium fuel cycle sources in order to assess compliance with 40CFR190 as part of demonstrating compliance with 10CFR20.
The total dose for the uranium fuel cycle is the sum of doses due to radioactivity in airborne and liquid effluents and the doses due to direct radiation from contained sources at the nuclear power station. When evaluation of total dose is required for a station, the following contributions are summed:
- Doses due to airborne and liquid effluents from the station.
- Doses due to liquid effluents from nuclear power stations upstream.
- Doses due to any onsite radioactive waste storage facilities, if applicable.
- Doses due to any onsite Independent Spent Fuel Storage Installations (ISFSI)
- Doses due to nitrogen - 16 (N16) skyshine.
10CFR20 requires compliance to dose limits expressed as "Total Effective Dose Equivalent" (TEDE). Although annual dose limits in 10CFR20 are now expressed in terms of TEDEs, 40CFR190 limits remain stated as organ dose. The NRC continues to require 10CFR50 Appendix I and 40CFR190 doses to be reported in terms of organ dose and not TEDE. Due to the fact that organ dose limits set forth in 40CFR190 are substantially lower than those of 10CFR20 (25 mrem/yr vs. 100 mrem/yr), the NRC has stated that demonstration of compliance with the dose limits in 40CFR190 will Page II.5-1 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual be deemed as demonstration of compliance with the dose limits of 10CFR20 for most facilities (Reference 104). In addition to compliance with 40CFR190, it may be necessary for a nuclear power plant to address dose from on-site activity by members of the public.
5.1.2 Total Dose Calculation Methodology There are presently two types of contained sources of radioactivity that are of concern in LaSalle Stations offsite radiological dose assessments. The first source is that due to gamma radiation from nitrogen-16 (16N) carried over to the turbine in BWR (boiling water reactor) steam. The second source is that due to radiation associated with radioactive material resident in onsite Independent Spent Fuel Storage Installations (gamma and neutron radiation) and radwaste storage facilities (gamma radiation).
Radiation from these sources contributes to the total body dose (deep dose equivalent). In addition to the total body, skin and single organ dose assessments previously described, an additional assessment is required. The additional assessment addresses radiation dose due to radioactivity contained within the nuclear power station and its structures.
5.1.3 BWR Skyshine The most significant dose component to members of the public produced by "contained sources" is nitrogen-16 (16N) within the turbine building of BWRs. Although primary side shielding is around the turbine and its piping, 16N gamma rays scattered by air molecules in the overhead air space above the turbine and piping cause a measurable "skyshine" radiation dose in the local power plant environs.
Equation 5-1 is used to evaluate skyshine dose. A complicating factor in the calculation is the practice at some stations of adding hydrogen to reactor coolant to improve coolant chemistry. The addition of hydrogen can increase the dose rate due to skyshine up to a factor of 10 times expected levels depending on injection rates and power levels (Reference 39). Increasing the hydrogen injection rate will increase the dose rates even further. (See Reference 102)
The skyshine dose determined by Equation 5-1 depends on the following factors:
- The distance of the dose recipient location from the turbine.
Page II.5-2 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual
- The number of hours per year that the location is occupied by a dose recipient.
- The total energy [MWe-hr] generated by the nuclear power station with hydrogen addition.
- The total energy [MWe-hr] generated by the nuclear power station without hydrogen addition.
5.1.4 Independent Spent Fuel Storage Installation (ISFSI) 10CFR72.104 dose limits are the same as those specified by 40CFR190.
Even a fully loaded ISFSI is not expected to become the prominent contributor to the limits in this section. ISFSI dose contribution is in the form of direct radiation as no liquid or gas releases are expected to occur. The 10CFR72.212 report prepared in accordance with ISFSI requirements assumes a certain array of casks exists on the pad. The dose contribution from this array of casks, in combination with historical uranium fuel cycle operations (e.g. LSCS 1 & 2) prior to ISFSI operations, was analyzed to be within the 40CFR190 and 10CFR72.104 limits.
If the dose limits of 40CFR190 or 10CFR72.104 are exceeded, a special report to the NRC as well as an appropriate request for exemption/variance is required to be submitted to the NRC.
The requirement that the dose limits of 10CFR72.104 apply to any real individual is controlled for ISFSI activities in the ISFSI 72.212 report. The nearest real individual to the ISFSI was also determined to be the nearest real individual to the plant. Therefore, for the purposes of analyzing dose, the member of the public as defined in 40CFR190 is the same as the real individual identified in the 72.212 report. The dose rate calculated to the nearest real individual from a fully loaded ISFSI (as listed in the 10CFR72.212 report) is 5.87E-02 mRem/year. To ensure compliance in a conservative fashion, one half of the annual ISFSI dose will be added to each Units external body dose, assuming a fully loaded ISFSI under the conditions listed in the LaSalle 10CFR72.212 report.
5.1.5 Non Fuel Waste (NFW) Storage LaSalle has implemented Non Fuel Waste (NFW) storage on site.
The waste is stored in above ground Non Fuel Waste Canisters Page II.5-3 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual (NFWCs) known as HI-SAFE storage modules. The waste is stored on the turning pads at the existing LaSalle ISFSI. A bounding study was performed based on data provided by the HI-SAFE manufacturer and Site Engineering. No liquid or gaseous releases are expected to occur, as the NFWCs are sealed under vacuum. Thus, only dose contributions due to direct radiation are considered. The study concluded that in accordance with NRC guidance, there would not be a significant contribution to offsite doses with regard to the NFW storage.
5.2 BWR Skyshine Calculation The contained onsite radioactivity source that results in the most significant offsite radiation levels at LaSalle Station is skyshine resulting from 16N decay inside turbines and steam piping.
The 16N that produces the skyshine effect is formulated through neutron activation of the oxygen atoms (oxygen-16, or 16O) in reactor coolant as the coolant passes through the operating reactor core. The 16N travels with the steam produced in the reactor to the steam driven turbine. While the 16N is in transport, it radioactively decays with a half-life of about 7 seconds and produces 6 to 7 MeV gamma rays. Typically, offsite dose points are shielded from a direct view of components containing 16N, but there can be skyshine radiation at offsite locations due to scattering of gamma rays off the mass of air above the steamlines and turbine.
The offsite dose rate due to skyshine has been found to have the following dependencies:
- The dose rate decreases as distance from the station increases.
- The dose rate increases non-linearly as the power production level increases.
- The dose rate increases when hydrogen is added to the reactor coolant, an action taken to improve reactor coolant chemistry characteristics (see Reference 39).
To calculate offsite dose due to skyshine in a given time period due to skyshine, LaSalle Station must track the following parameters:
- The total gross energy Eh produced with hydrogen being added.
- The total gross energy Eo produced without hydrogen being added.
The turbines at the site are sufficiently close to each other that energy generated by the two operating units at may be summed.
Page II.5-4 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual An initial estimate of skyshine dose is calculated per the following equation:
D Sky = (K )(E o + M h E h ) {OF K SFK e 0.007R K } (5-1)
The summation is over all locations k occupied by a hypothetical maximally exposed member of the public characterized by the parameters specified in ODCM Table 4-8. The parameters in Equation 5-1 are defined as follows:
DSsky Dose Due to N-16 Skyshine [mrem]
Gamma External direct gamma dose (deep dose equivalent) due to BWR N-16 skyshine for the time period of interest.
K Empirical Constant [mrem/(MWe-hr)]
A constant determined by fitting data measured at the each station.
Eo Electrical Energy Generated Without Hydrogen Addition [MWe-hr]
Total gross electrical energy generated without hydrogen addition in the time period of interest.
Eh Electrical Energy Generated with Hydrogen Addition [MWe-hr]
Total gross electrical energy generated with hydrogen addition in the period of interest.
Mh Multiplication Factor for Hydrogen Addition [dimensionless]
Factor applied to offsite dose rate when skyshine is present. Hydrogen addition increases main steam line radiation levels typically up to a factor of approximately 5 (see Page 8-1 of Reference 39). Mh is station specific and is given in ODCM Table 4-8.
Page II.5-5 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual OFk Occupancy Factor [dimensionless]
The fraction of time that the dose recipient spends at location k during the period of interest. See ODCM Table 4-8.
SFk Shielding Factor [dimensionless]
A dimensionless factor that accounts for shielding due to occupancy of structures.
SFk = 0.7 if there is a structure at location k; SFk = 1.0 otherwise. See ODCM Table 4-8.
0.007 Empirical Constant [m-1]
A constant determined by fitting data measured at the LaSalle station (see Reference 45).
Rk Distance [m]
Distance from the turbine to location k. See ODCM Table 4-8.
5.3 Onsite Radwaste and Rad Material Storage Facilities 5.3.1 Process Waste Storage Facilities
- Interim Radwaste Storage Facility (IRSF) structure
- Concrete vaults containing radwaste liners 5.3.2 DAW Storage Facilities
- Dry Active Waste (DAW) facilities (may include Butler buildings/warehouses)
- Seavans or other temporary warehouses 5.3.3 ISFSI Facilities
- Independent spent fuel storage installation facilities.
5.4 Methodology The external total body dose is comprised of the following parts:
- 1) Total body dose due to noble gas radionuclides in gaseous effluents (Section 4.2.1.1),
Page II.5-6 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual
- 2) Dose due to 16N skyshine (section 0) and other contained sources (section 5.3) and
- 3) Total body dose due to radioactivity deposited on the ground (Section 4.2.3.1).
The external total body dose due to radioactivity deposited on the ground is accounted for in the determination of the non-noble gas dose and is considered in section 5.5.
The total external total body dose, DEx, is given by:
DEx = DTB + DSky + DOSF (5-2)
DEx Total External Total Body Dose [mrem]
Total external total body dose due to irradiation by external sources at the location of interest.
DTB Noble Gas Total Body Dose [mrem]
External total body dose due to gamma radiation from noble gas radionuclides released in gaseous effluents at the location of interest. See Section 4.2.2.3.
DSky Dose Due to N-16 Skyshine Total Body Dose [mrem]
External total body dose due to N-16 skyshine for the period and location of interest. See Equation 5-1.
DOSF Dose From On-Site Storage Facilities [mrem]
External total body dose due to radiation from on-site storage facilities at the location of interest. See Section 5.3.
5.5 Total Dose The total dose, DTot, in the unrestricted area to a member of the public due to plant operations is given by:
D Tot = D Ex + D Liq NNG aj + D aj (5-3) where:
D Tot Total Dose To Member of Public [mrem]
Page II.5-7 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Total off-site dose to a member of public due to plant operations.
D Ex Total External Total Body Dose [mrem]
Total body dose due to external exposure to noble gases, N-16 skyshine and on-site storage facilities.
D Liq aj Liquid Effluent Dose [mrem]
Dose due to liquid effluents to age group a and organ
- j. The age group and organ with the highest dose from liquid effluents is used.
D NNG aj Non-Noble Gaseous Effluent Dose [mrem]
Dose due to non-noble gaseous effluents to age group a and organ j. The age group and organ with the highest dose from non-noble gas effluents is used.
5.6 COMPLIANCE TO TOTAL DOSE LIMITS 5.6.1 Total Effective Dose Equivalent Limit - 10CFR20 Compliance Each station's RECS limits the Total Effective Dose Equivalent (TEDE) to an annual limit of 100 mrem, as required by 10CFR20.1301 (a)(1). Demonstration of compliance with the limits of 40CFR190 (per Section 4.2.2) will be considered to demonstrate compliance with the 100 mrem/year limit.
5.6.2 Dose to a MEMBER OF THE PUBLIC in the Unrestricted Area The NRC has stated that demonstration of compliance with the limits of 40CFR190 or with the design objectives of Appendix I to 10CFR50 will be deemed to demonstrate compliance with the limits of 10CFR20.1301(a)(1). Power reactors that comply with Appendix I may also have to demonstrate that they are within the 25 mrem limit of 40CFR190 (See Reference 104).
5.6.3 Dose to a MEMBER OF THE PUBLIC in the Restricted Area Page II.5-8 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual In August of 1995, a revision to 10CFR20 was implemented that changed the definition of a member of the public. As a result, for each nuclear station, estimated doses were calculated for a member of the public who enters the site boundary, but is not authorized for unescorted access to the protected area of the site and does not enter any radiologically posted areas on the site.
Realistic assumptions were made for occupancy times and locations visited while within the site boundary.
These evaluations indicate that the doses estimated for these members of the public are well within the 10CFR20 limits.
Evaluation of the 40CFR190 dose is used to demonstrate compliance to 10CFR20 and satisfy station RECS and Technical Specifications (see ODCM Part I).
5.6.4 Total Dose due to the Uranium Fuel Cycle (40CFR190)
RECS and 40CFR190 limit the annual (calendar year) dose or dose commitment to any member of the public due to releases of radioactivity and to radiation from uranium fuel cycle sources to the following:
- Less than or equal to 25 mrem to the total body.
- Less than or equal to 25 mrem to any organ except the thyroid.
- Less than or equal to 75 mrem to the thyroid.
Total Dose Components This requirement includes the total dose from operations at the nuclear power station. This includes doses due to radioactive effluents (airborne and liquid) and dose due to direct radiation from non-effluent sources (e.g., sources contained in systems on site). It also includes dose due to plants under consideration, neighboring plants and dose due to other facilities in the uranium fuel cycle.
The operations comprising the uranium fuel cycle are specified in 40CFR190.02(b). The following are included to the extent that they directly support the production of electrical power for public use utilizing nuclear energy:
- Milling of uranium ore.
- Chemical conversion of uranium.
Page II.5-9 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual
- Isotopic enrichment of uranium.
- Fabrication of uranium fuel.
- Generation of electricity by a light-watered-cooled nuclear power plant using uranium fuel.
- Reprocessing of spent uranium fuel.
Excluded are:
- Mining operations.
- Operations at waste disposal sites.
- Transportation of any radioactive material in support of these operations.
- The re-use of recovered non-uranium special nuclear and by-product materials from the cycle.
5.7 When Compliance Assessment is Required Compliance with the 40CFR190 regulations is now required as part of demonstration of compliance to 10CFR20 regulations per 10CFR20.1301(d).
The dose due to the uranium fuel cycle is determined by equation 5-3 Page II.5-10 LaSalle ODCM Part II Section 5
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual 6.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM The Radiological Environmental Monitoring Program for the environs around LaSalle Station is given in Table 6-1.
Figure 6-1 through Figure 6-3 show sampling and monitoring locations.
II.6-1 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 1 of 8)
Radiological Environmental Monitoring Program Exposure Pathway Sampling or Collection Type and Frequency of Sample or Monitoring Location and/or Sample Frequency Analysis
- 1. Airborne Continuous sampler Radioiodine Canisters:
operation with particulate a.Radioiodine 1). Indicators-Near Field sample collection weekly, I-131 analysis weekly on and Particulates or more frequently if near field and control L-01, Nearsite No. 1, 1.5 mi (2.4 km) NNW (N 41° 16.016, W 88° 40.920) required by dust loading, samples1.
L-03, Onsite No. 3, 1.0 mi (1.6 km) ENE (N 41° 15.145, W 88° 39.174) and radioiodine canister L-05, Onsite No. 5, 0.3 mi (0.5 km) ESE (N 41° 14.520, W 88° 39.355) collection weekly. Particulate Sampler:
L-06, Nearsite No. 6, 0.4 mi (0.6 km) W (N 41° 14.602, W 88° 41.056)
Gross beta analysis following weekly filter change2 and gamma isotopic analysis3 quarterly on composite filters by location on near field and control samples.1
- 2. Indicators-Far Field L-04, Rte 170, 3.2 mi (5.1 km) E (N 41° 15.243, W 88° 36.451)
L-07, Seneca, 5.2 mi (8.4 km ) NNE (N 41° 19.093, W 88° 36.473)
L-08, Marseilles, 6.0 mi (9.7 km) NNW (N 41° 19.645, W 88° 42.925)
L-11A, Ransom, 6.0 mi (9.7 km) S (N 41° 09.405, W 88° 39.565)
II.6-2 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 2 of 8)
Radiological Environmental Monitoring Program Exposure Pathway Sampling or Collection Type and Frequency of Sample or Monitoring Location and/or Sample Frequency Analysis
- 2. Direct Radiation 1) Indicators-Inner Ring Quarterly Gamma dose on each Field L-101-1, 0.5 mi (0.8 km) N (N 41° 15.084, W 88°40.087) Dosimeter quarterly.
- a. Field Dosimeter L-101-2, 0.5 mi (0.8 km) N (N 41° 15.084, W 88°40.087)
L-102-1, 0.6 mi (1.0 km) NNE (N 41° 15.226, W 88°39.915 L-102-2, 0.6 mi (1.0 km) NNE (N 41° 15.226, W 88°39.915 L-103-1, 0.7 mi (1.1 km) NE (N 41° 15.168, W 88°39.492)
L-103-2, 0.7 mi (1.1 km) NE (N 41° 15.168, W 88°39.492)
L-104-1, 0.8 mi (1.3 km) ENE (N 41° 15.138, W 88°39.185)
L-104-2, 0.8 mi (1.3 km) ENE (N 41° 15.138, W 88°39.185)
L-105-1, 0.7 mi (1.1 km) E (N 41° 14.724, W 88°39.425)
L-105-2, 0.7 mi (1.1 km) E (N 41° 14.724, W 88°39.425)
L-106-1, 1.4 mi (2.2 km) ESE (N 41° 14.328, W 88°38.751)
L-106-2, 1.4 mi (2.2 km) ESE (N 41° 14.328, W 88°38.751)
L-107-1, 0.8 mi (1.3 km) SE (N 41° 14.308, W 88°39.502)
L-107-2, 0.8 mi (1.3 km) SE (N 41° 14.308, W 88°39.502)
L-108-1, 0.5 mi (0.8 km) SSE (N 41° 14.305, W 88°39.825)
L-108-2, 0.5 mi (0.8 km) SSE (N 41° 14.305, W 88°39.825)
L-109-1, 0.6 mi (1.0 km) S (N 41° 14.299, W 88°40.106)
L-109-2, 0.6 mi (1.0 km) S (N 41° 14.299, W 88°40.106)
L-110-1, 0.6 mi (1.0 km) SSW (N 41° 14.290, W 88°40.388)
L-110-2, 0.6 mi (1.0 km) SSW (N 41° 14.290, W 88°40.388)
L-111b-1, 0.8 mi (1.3 km) SW (N 41° 14.277, W 88°40.878)
L-111b-2, 0.8 mi (1.3 km) SW (N 41° 14.277, W 88°40.878)
L-112-1, 0.9 mi (1.4 km) WSW (N 41° 14.403, W 88°41.050)
L-112-2, 0.9 mi (1.4 km) WSW (N 41° 14.403, W 88°41.050)
L-113a-1, 0.8 mi (1.3 km) W (N 41° 14.658, W 88°41.055)
L-113a-2, 0.8 mi (1.3 km) W (N 41° 14.658, W 88°41.055)
L-114-1, 0.9 mi (1.4 km) WNW (N 41° 14.991, W 88°41.070)
L-114-2, 0.9 mi (1.4 km) WNW (N 41° 14.991, W 88°41.070)
L-115-1, 0.7 mi (1.1 km) NW (N 41° 15.054, W 88°40.529)
L-115-2, 0.7 mi (1.1 km) NW (N 41° 15.054, W 88°40.529)
L-116-1, 0.6 mi (1.0 km) NNW (N 41° 15.210, W 88°40.366)
L-116-2, 0.6 mi (1.0 km) NNW (N 41° 15.210, W 88°40.366)
II.6-3 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 3 of 8)
Radiological Environmental Monitoring Program Exposure Pathway Sampling or Collection Type and Frequency of Sample or Monitoring Location and/or Sample Frequency Analysis
- 2. Direct Radiation 2) Indicators-Outer Ring Quarterly Gamma dose on each Field (Cont'd) L-201-3, 4.0 mi (6.4 km) N (N 41° 18.205, W 88°40.162) Dosimeter quarterly.
- a. Field Dosimeter L-201-4, 4.0 mi (6.4 km) N (N 41° 18.205, W 88°40.162)
L-202-3, 3.6 mi (5.8 km) NNE (N 41° 17.793, W 88°38.287)
L-202-4, 3.6 mi (5.8 km) NNE (N 41° 17.793, W 88°38.287)
L-203-1, 4.0 mi (6.4 km) NE (N 41° 17.291, W 88°36.311)
L-203-2, 4.0 mi (6.4 km) NE (N 41° 17.291, W 88°36.311)
L-204-1, 3.2 mi (5.2 km) ENE (N 41° 15.346, W 88°36.442)
L-204-2, 3.2 mi (5.2 km) ENE (N 41° 15.346, W 88°36.442)
L-205-1, 3.2 mi (5.2 km) ESE (N 41° 14.144, W 88°36.410)
L-205-2, 3.2 mi (5.2 km) ESE (N 41° 14.144, W 88°36.410)
L-205-3, 5.1 mi (8.2 km) E (N 41° 14.774, W 88°34.209)
L-205-4, 5.1 mi (8.2 km) E (N 41° 14.774, W 88°34.209)
L-206-1, 4.3 mi (6.9 km) SE (N 41° 12.825, W 88°36.388)
L-206-2, 4.3 mi (6.9 km) SE (N 41° 12.825, W 88°36.388)
L-207-1, 4.5 mi (7.2 km) SSE (N 41° 11.476, W 88°37.546)
L-207-2, 4.5 mi (7.2 km) SSE (N 41° 11.476, W 88°37.546)
L-208-1, 4.5 mi (7.2 km) S (N 41° 10.818, W 88°39.432)
L-208-2, 4.5 mi (7.2 km) S (N 41° 10.818, W 88°39.432)
L-209-1, 4.0 mi (6.4 km) SSW (N 41° 11.662, W 88°41.173)
L-209-2, 4.0 mi (6.4 km) SSW (N 41° 11.662, W 88°41.173)
L-210-1, 3.3 mi (5.3 km) SW (N 41° 12.519, W 88°42.364)
L-210-2, 3.3 mi (5.3 km) SW (N 41° 12.519, W 88°42.364)
L-211-1, 4.5 mi (7.2 km) WSW (N 41° 12.557, W 88°44.489)
L-211-2, 4.5 mi (7.2 km) WSW (N 41° 12.557, W 88°44.489)
L-212-1, 4.0 mi (6.4 km) W(N 41° 14.095, W 88°44.508)
L-212-2, 4.0 mi (6.4 km) W (N 41° 14.095, W 88°44.508)
L-213-3, 4.9 mi (7.9 km) W (N 41° 14.402, W 88°45.674)
L-213-4, 4.9 mi (7.9 km) W (N 41° 14.402, W 88°45.674)
L-214-3, 5.1 mi (8.2 km) WNW (N 41° 16.028, W 88°45.708)
L-214-4, 5.1 mi (8.2 km) WNW (N 41° 16.028, W 88°45.708)
L-215-3, 5.0 mi (8.0 km) NW (N 41° 17.760, W 88°44.133)
L-215-4, 5.0 mi (8.0 km) NW (N 41° 17.760, W 88°44.133)
L-216-3, 5.0 mi (8.0 km) NNW (N 41° 18.823, W 88°42.087)
L-216-4, 5.0 mi (8.0 km)NNW (N 41° 18.823, W 88°42.087)
II.6-4 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 4 of 8)
Radiological Environmental Monitoring Program Exposure Pathway Sampling or Collection Type and Frequency of Sample or Monitoring Location and/or Sample Frequency Analysis
- 2. Direct Radiation 3) Indicators - Other Quarterly Gamma dose on each Field (Cont'd) Dosimeter quarterly.
- a. Field Dosimeter One at each of the airborne location given in part 1.a.1 and 1.a.2 4). Controls One at each airborne control location given in part 1.a.3 II.6-5 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 5 of 8)
Radiological Environmental Monitoring Program Exposure Pathway and/or Sampling or Collection Type and Frequency of Sample or Monitoring Location Sample Frequency Analysis
- 3. Waterborne
- a. Ground/Well 1) Indicators Quarterly Gamma isotopic3 and tritium analysis quarterly.
L-27, LSCS Onsite Well at Station (N 41° 14.665, W 88° 40.127)
L-28 #6, Marseilles Well, 4.1 mi (11.3 km ) N (N 41° 18.215, W 88° 39.430)
- 2) Control Alternate based on availability L-28 #4, Marseilles Well, 7.0 mi (10.9 km) NNW (N 41° 20.367, W 88° 42.054)
L-28 #5, Marseilles Well, 6.7 mi (10.km) NNW (N 41° 20.142, W 88° 42.563)
- b. Drinking Water There is no drinking water pathway within 6.2 mi (10 km) downstream of station.
- c. Surface Water 1) Indicator Weekly grab sample Gross beta and gamma L-40, Illinois River downstream, isotopic analysis3 on monthly 5.2 mi (8.4 km) NNW composite; tritium analysis on (N 41° 19.230, W 88° 42.048) quarterly composite.
- d. Sediments
- 1) Indicators Semiannually Gamma isotopic analysis3 L-40, Illinois River downstream, 5.2 mi (8.4 km) NNW semiannually.
(N 41° 19.230, W 88° 42.048)
L-41, Illinois River downstream 4.6 mi (7.4 km) N (N 41° 18.678, W 88° 40.368)
II.6-6 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 6 of 8)
Radiological Environmental Monitoring Program Exposure Pathway Sampling or Collection Type and Frequency of Sample or Monitoring Location and/or Sample Frequency Analysis
- 4. Ingestion
- 1) Indicators
- a. Milk At the time of this revision, there are no dairies within 6.2 Biweekly: May through Gamma isotopic3 and I-131 miles which consistently produce milk. October; monthly: November analysis4 biweekly May through April through October, monthly
- 2) Controls November through April.
L-42, Biros Dairy, 14.2 mi (22.9 km)E (N 41° 15.379, W 88° 23.823)
- b. Fish 1) Indicator Two times annually Gamma isotopic analysis3 L-35, Marseilles Pool of Illinois River, on edible portions of each 6.5 mi (10.5 km)NNW (N 41° 19.386, W 88° 42.492)
L-34, LaSalle Lake 2 mi (3.2 km) E
- 2) Control L-36, Illinois River upstream of discharge, 4.3 mi (6.9 km) NE (N 41° 17.892, W 88° 36.308)
- c. Food Products a. Indicators Annually Gamma isotopic analysis3 and I-131 analysis each Two samples from each of the four major quadrants within sample.
6.2 miles (10 km) of the station, if available.
Sample locations for food products may vary based on availability and therefore are not required to be identified here but shall be taken. Refer to most recent Land Use Census for specific garden locations.
- b. Controls Two samples within 9.3 to 18.6 miles (15 to 30 km) of the station, if available. Refer to most recent Land Use Census for specific garden locations.
II.6-7 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 7 of 8)
Radiological Environmental Monitoring Program Exposure Pathway Sampling or Collection Type and Frequency of Sample or Monitoring Location and/or Sample Frequency Analysis
- 4. Ingestion (contd) Monthly during the Gamma isotopic analysis3
NOTE--------------------------------
growing season (May and I-131 analysis on each
- d. Vegetation These vegetation samples are only required if milk sampling is through October) sample.
not performed.
- a. Indicator Samples of 3 different types of broadleaf vegetation within 10km (6.2 miles) at 2 different offsite locations in the highest D/Q sector of the station, if available Sample locations for vegetation may vary based on availability and therefore are not required to be identified here but shall be taken. Refer to most recent Land Use Census for specific vegetation locations.
- b. Control Samples of 3 different types of broadleaf vegetation within 15 to 30km (9.3 to 18.6 miles) in the lowest D/Q sector of the station, if available. Refer to most recent Land Use Census for specific vegetation loacations.
II.6-8 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Table 6-1 (Page 8 of 8)
Radiological Environmental Monitoring Program 1 Far field samples are analyzed when near field results are inconsistent with previous measurements and radioactivity is confirmed as having its origin in airborne effluents released from the station, or at the discretion of the ODCM Specialist.
2 Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thorium daughter decay. If gross beta activity in air particulate samples is greater than 10 times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.
3 Gamma isotopic analysis means the identification and quantification of gamma emitting radionuclides that may be attributable to the effluents from the station.
4 I-131 analysis means the analytical separation and counting procedure are specific for this radionuclide.
II.6-9 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Figure 6-1 Fixed Air Sampling Sites and Outer Ring Field Dosimeter Locations A
II.6-10 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Figure 6-2 Inner Ring Field Dosimeters Locations II.6-11 LaSalle ODCM Part II Section 6
CY-LA-170-301 Revision 10 September 2021 Part II, Offsite Dose Calculation Manual Figure 6-3 Ingestion and Waterborne Exposure Pathway Sample Locations II.6-12 LaSalle ODCM Part II Section 6