RS-06-106, Additional Information Supporting the License Amendment Request to Technical Specification 3.7.3, Ultimate Heat Sink.
ML062160395 | |
Person / Time | |
---|---|
Site: | LaSalle ![]() |
Issue date: | 08/04/2006 |
From: | Benyak D Exelon Generation Co, Exelon Nuclear |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
RS-06-106 | |
Download: ML062160395 (29) | |
Text
RS-06-106 10 CFR 50.90 August 4, 2006 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D . C. 20555 LaSalle County Station, Units 1 and 2 Facility Operating License Nos. NPF-1 1 and NPF-18 NRC Docket Nos. 50-373 and 50374
Subject:
Additional Information Supporting the License Amendment Request to Technical Specification 3.7.3, "Ultimate Heat Sink" References : 1 . Letter from K. R. Jury (Exelon Generation Company, LLC) to U .S. NRC, "Request for a License Amendment to Technical Specification 3.7.3, Ultimate Heat Sink," dated March 13, 2006
- 2. U.S . NRC to C. M. Crane (Exelon Generation Company, LLC), "LaSalle County Power Station, Units 1 and 2 - Request for Additional Information Related to Ultimate Heat Sink License Amendment Request," dated June 15, 2006
- 3. Letter from J . A. Bauer (Exelon Generation Company, LLC), "Additional Information Supporting the License Amendment Request to Technical Specification 3.7.3, "Ultimate Heat Sink," dated July 13, 2006 In Reference 1, Exelon Generation Company, LLC, (EGC), requested an amendment to Appendix A, Technical Specifications (TS), of Facility Operating License Nos . NPF-1 1 and NPF-18 for LaSalle County Station (LSCS) Units 1 and 2 respectively . Specifically, the proposed change increases the temperature limit of the cooling water supplied to the plant from the Core Standby Cooling System (CSCS) pond (i .e ., the Ultimate Heat Sink (UHS)) from
- 5 100OF to :5 101 .50 F. This increase is achieved by reducing the temperature measurement uncertainty by replacing the existing thermocouples with higher precision temperature measuring equipment.
In Reference 2, the NRC requested additional information to complete the review of the proposed license amendment. In Reference 3, EGC provided the additional information requested.
August 4, 2006 U. S. Nuclear Regulatory Commission Page 2 In an email dated July 19, 2006, from Stephen Sands, NRC Project Manager to Alison Mackellar, EGC Licensing Engineer ; additional information was requested to complete the review of the proposed license amendment. A telephone conference was held on July 20, 2006, between the NRC and EGC to discuss the additional questions. At that meeting EGC agreed to provide the following information to the NRC.
1 . Vendor data sheets for the newly installed equipment used to measure the UHS temperature
- 2. A more detailed calculation of the uncertainty error provides the detailed calculation requested including vendor supplied technical data .
Note that the purpose of the detailed calculation is to confirm that the original uncertainty calculation, provided in Reference 3, remains bounding. The detailed calculation was performed in accordance with EGC methodology for instrument uncertainty for safety related indicating loops.
EGC has reviewed the information supporting a finding of no significant hazards consideration that was previously provided to the NRC in Attachment 1 of Reference 1 . The supplemental information provided in this submittal does not affect the bases for concluding that the proposed license amendment does not involve a significant hazards consideration.
Should you have any questions concerning this letter, please contact Ms. Alison Mackellar at (630) 657-2817 .
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 4th day of August 2006.
Respectfully, Darin M. Benyak Manager - Licensing : LSCS Calculation L-003230, "CW Inlet Temperature Uncertainty Analysis"
Attachment 1 LaSalle County Station Calculation L-003230 CW Inlet Temperature Uncertainty Analysis
CC-AA-309-1001 Revision 1 ATTACHMENT 1 Design Analysis Cover Sheet
~ Last Page No. 1 4 Analysis No. L-003230 Revision 000 EC/ECR No. 361689 Revision 000
Title:
CW Inlet Temperature Uncertainty Analysis Station(s) LaSalle Component(s)
Unit No .: 1,2 1TE-CW010 2TE-CW010 Discipline I&C 1 TE-CW01 1 2TE-CW01 1 Description Cadet 104 1TT-CW010 2TT-CW010 Keyword Safety Class NSR 1 TT-CW01 I 2TOCW01 1 System Code CW U1 Computer Point F285 U2 Computer Point F285 Structure N/A l_U1 Computer Point F286- U2 Computer Point F286 CONTROLLED DOCUMENT REFERENCES Document No. I Document No. FrorrvTo Is this Design Analysis Safeguards? Yes No Does this Design Analysis Contain Unverified Assumptions? Yes No Z ATI/AR#
Is a Supplemental Review Required? If yes, complete Y' 0 No Attachment 3-Preparer T. J. Van Wyk Print Name J-SName (Date Reviewer V. R. Shah Print Name eyo""l Sign Name Date Method of Review 401 Detailed Review LF ji AIf t eate Ca I tff:at-yr'~ M
, Testing Review Notes:
Approver Print Name `- Sign am Date (For External Analyses Only)
Exelon Reviewer N/A Print Name Sign Name Date Approver N/A Print Name Sign Name Date Description of Revision (list affected pages for partials) :
THIS DESIGN ANALYSIS SUPERCEDES :
CALCULATION TABLE OF CONTENTS CALCULATION NO. L-003230 Revision 000 PAGE NO. 2 SECTION : PAGE NO. SUB-PAGE NO .
TABLE OF CONTENTS 2 PURPOSE / OBJECTIVE 3 METHODOLOGY AND ACCEPTANCE CRITERIA 3 ASSUMPTIONS AND LIMITATIONS 3 DESIGN INPUT 3 REFERENCES 6 CALCULATIONS 7
SUMMARY
AND CONCLUSIONS (Total Error) 13 ATTACHMENTS:
A. Minco@ Quotation 160056-2, January 26, 2006 Al B. Minco@ Drawing 5100995, dated 4/27/99 131 C. E-mail from Keith Jensen of Minco@ to Vikram Shah of LaSalle dated C1 70546 D. ifm efector6000 TR2432 Operating Instructions, 701724/01, dated DI -D2 02/04 (Partial)
E. Letter dated from Ameera Shah of ifm efector to Vikrarn Shah of LaSalle El T%16 F. Fluke@ 45 Dual Display Multimeter User's Manual, Rev. 4, dated F1 07/97 (Specification Page only)
G. SOLAO SDN Power Supplies Specifications for SDN 2.5-24-100P G1 H. RTP@ RTP2000 Setup and Installation Guide, UG-2000-001, dated 9/12/02 (Partial) H1 1 . Minco Report of Calibration for Platinum RTD, Model S100995PD, Serial No. P/N366 (Partial) 11-12 J. HP 34401A Multimeter User's Guide, Edition 4, printed February J1 1996 (Specification Page only)
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE 1 PURPOSE / OBJECTIVE 1 .1 The purpose of this calculation is to evaluate the loop uncertainty for the CW Inlet Temperature Indication Loops . These are revised instrument loops that were implemented by EC359060 for Unit 1 and EC359114 for Unit 2 .
1 .2 These instrument loops provide Ultimate Heat Sink (UHS) temperature indication via the Plant Process Computer (PPC). These new loop configurations replaced the existing thermocouples 1(2)CW010/01 1 (the sensing elements for computer points F2855286) with new RTD temperature sensing elements and new temperature compensators (transmitters), and relocated the computer inputs to the appropriate Input/Output (1/0) analog input cards.
2 METHODOLOGY AND ACCEPTANCE CRITERIA 2.1 The methodology used for this calculation is based on NES-EEC-20.04 "Analysis of Instrument Channel Setpoint Error and Instrument Loop Accuracy", Rev . 4 (Reference 5.1 .2) . Additionally, for calculating the average uncertainty using up to four indicating loops, the multiple test criterion of ASME PTC 19.1 (Ref. 5.1 .4), Section 3.2 was used.
2.2 The instrumentation evaluated in this calculation provides indication (via the Plant Process Computer) for Ultimate Heat Sink Temperature. This is a non-safety indication loop, but the indication is used to verify the Technical Specification SR 3.7.3.1 is met. In accordance with Reference 5.1 .2, Appendix D, a Level 3 evaluation is appropriate for this analysis. However, in response to questions during the NRC review of the License Amendment Request to increase the UHS temperature surveillance requirement value, this analysis will evaluate all uncertainty terms and determine the total uncertainty value using methodology consistent with safety-related indicating loops (Reference 5.1 .2, Appendix D, Level 2).
2.3 Temperature, humidity and pressure errors, when available from the manufacturer, are to be evaluated with respect to the conditions specified in the station EQ Zones . If not provided, an evaluation must be made to ensure that the environmental conditions are bounded by the manufacturer's specified operational limits. If the environmental conditions are bounded, these error effects are considered to be included in the manufacturer's reference accuracy.
2.4 Published instrument vendor specifications are considered to be based on sufficiently large the samples so that the probability and confidence level mess 2a criteria, unless stated otherwise by the vendor (Reference 5.1 .2, Appendix A, Section 8.0) .
2.5 For normal error analysis, normal vibrations and seismic effects are considered negligible or capable of being calibrated out in accordance with Appendix I of Reference 5.1 .2.
2.6 The calibration standard error is considered negligible; the calibration standard error (STD) is more accurate than the M&TE by a ratio of at least 4:1 (Reference 5.1 .2, Appendix A, Section 5.1 .4) .
2.7 The insulation resistance error is considered negligible unless the instrumentation is expected to operate in an abnormal or harsh environment (Reference 5.1 .2, Appendix A, Section 7.0) .
2.8 Reference 5.1 .2, Appendix I states that the effects of normal radiation are small and accounted for in the periodic calibration process . Outside of containment during normal operation, the uncertainty introduced by radiation effects on components is considered to be negligible.
3 ASSUMPTIONS AND LIMITATIONS 3.1 Evaluation of M&TE errors for the digital multimeter is based on the assumption that the test equipment listed in Section 4.5 is used.
3.2 It is assumed that the calibration standard of the equipment utilized is more accurate than the M&TE equipment by a ratio of at least 4:1 such that the calibration standard errors can be considered
CALCULATION PAGE NO. L-003230 Revision 000 PAGE NO. 4 of 14 CALCULATION negligible with respect to the M&TE specification per its Section2.6. This is considered a reasonable assumption since M&TE equipment 4 certified to required accuracy under laboratory conditions .
4 DESIGN INPUTS 4.1 The new instrument loops will consist of the following components: high accuracy RTD temperature elements, temperature transmitters, precision input resistors at the field input to the 1/0 card, and the D/A conversion in the PPC 1/0 equipment. The loop components evaluated in this document have the following specifications :
4.1 .1 New Minco RTDs; in the existing thermowells (replacing the existing thermocouples) . The new RTDs have the following performance specifications (Ref. 5.4.1) :
Repeatability: +/-0.20F
[The RTDs are designed to EN60751 Class A specifications with high precision and repeatability requirements . Thus, this specification could be considered to be at a 36 confidence level . However, for conservatism, this specification will be used as a 26 value.]
Drift: 10.1 OF/year (Ref. 5.4.3)
[The study in Reference 5.5.3 shows that RTDs are inherently stable, and after the first few months following installation RTDs attain a stable condition from which it may not drift sufficiently to exceed accuracy limits. RTD cross-calibration is performed to identify if an element has experienced the significant drift . Although RTDs; am not separately calibrated, for conservatism the vendor's drift value will be expanded using the loop calibration interval of 4 years (+ 1 year late factor).]
4.1 .2 The resistance value equivalent to the temperature value of interest (101 .50F) for the RTDs was obtained from the Minco, calibration reports for the RTDs installed at LaSalle (Ref. 5.4.10). The highest of the four resistance values was 115 .0135 . This value will be used to determine the M&TE error for the indicating loop (applied to Module 2). The change in resistance per 1 OF change in temperature (0.214YOF) was also obtained using the actual resistance values in the calibration reports for 101 .50F and =50F.
4.1 .3 New ifm@ efector600 TR2432 temperature transmitter modules . These new modules have the following performance specification (Ref.5.4.4, 5.4.5) :
Accuracy (includes drift) : +/-0.540F / 2 years
`Temperature Drift' : +/-0.1% of measured range/ 100C
[Note : Ref. 5.4.5 indicates that the accuracy specification includes drift error and is warranted to hold the accuracy and drift within the specified value for 2 years. It further states that testing is performed on 100% of the devices after production to verify conformance with these specifications . Therefore, these values are 36 confidence level. It also states that the accuracy specification includes the resolution error and electronic component drift, and that there are no other environmental influences that will affect the accuracy specification .]
4.1 .4 PPC 110 input card. The 1/0 input cards have the following performance specification (Ref.5.4.9) : f2a)
Accuracy: +/-0.025% of full scale (30OF to 1200F) 4.2 RTD extension wire has the identical conductor types as the RTD, and therefore there is no emf drop or change in conductor size at the point of connection on the RTD (Ref. 5 .4.2) .
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO. 5 of 14 4.3 The Instrument Loop power supply is a SOLID SDN 2.5-24-100P (Ref. 5.4.8), which has the following performance specifications : [2a]
Output tolerance : + 2% overall (combined Line, load, time, and temperature related changes)
Temperature range : -10°C to 60"C Humidity : < 90% RH, non-condensing 4.4 The precision signal resistor at the input terminals of the 1/0 card (Module 3) is a high-precision resistor with a tolerance of +/- 0.02% (Reference 5.3.2) [2a]
4.5 The loop is calibrated using a variable resistance input (to simulate the RTD input), measured with either a Fluke 45 DMM or an HP 34401A, and reading the indicated temperature at the PPC . The calibration procedures (Ref. 5.2.1 and 5.2.2) each specify that one loop will be calibrated using either the Fluke 45 OR the HP 34401 A. The other loop must be calibrated using the other DMM .
4 .5.1 Reference Accuracy for the Fluke 45 (medium speed) on the 3000 range is:
(+/- 0.05% reading + 2 LSD + 0.020) (Ref. 5.4.6) [2a]
4.5.2 Reference Accuracy for the H P 34401A on the 1 k9l range is:
+/- (0.01% reading + 0.001% range) (Ref. 5.4.7) [2a]
Temperature coefficient for the HP 34401A on the 1W range is (for OOC to 180 C and 28 0C to 550C):
+/- (0.0006% of reading + 0.0001% of range /'C) (Ref. 5.4.7) [2(T]
4 .6 LOCAL SERVICE ENVIRONMENTS (Ref. 5.5,2) 1:7--- Table 4.6 RTDs lfm efector6OO TR2432 Plant Process Computer Zone ClA Location
-- Turbine l3lcig Control Room (Computer Room)
Temperature 831 F to 102 1 F 50 to 104'F (Normal : 65 to 851 F)
Pressure 0 Iwo 0.125 to +3 .0 "wc I
Humidity 39 to 47% RH_ 12 .6 to 90% RH (see note belomd
[Note: Per reference 5 .5.2, the no expected humidity this zone is 20 to 50% RH]
4.7 Calibration Tolerance The calibration tolerance for these indication loops is +/- 0.540 F. Per Ref . 5.1 .2, this is a &T value.
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO. 6 of 14 I
REFERENCES 5.1 METHODOLOGY 5.1 .1 ANS MSKS67 .04- Part 1-1994, "Setpoints for Nuclear Safety Related Instrumentation" 5.1 .2 NES-EIC-20.04, "Analysis of Instrument Channel Setpoint Error and Instrument Loop Accuracy,"
Revision 4 5.1 .3 ANSI/ISA TR67.04 .09, "Graded Approaches to Setpoint Determination," dated 10/15/05 5 .1 .4 ASME PTC 19.1, Part 1, "Measurement Uncertainty," 1985 5.2 PROCEDURES 5.2.1 LIP-CW-501 [New loop-specific calibration procedure in development; tracked by CAP process]
5.2.2 LIP-CW-601 [New loop-specific calibration procedure in development ; tracked by CAP process]
5.3 LASALLE STATION DRAWINGS 5.3.1 1 E- 1 (2)-4022ZC "Schematic Diagram, Circulating Water System CW Pt. 3," as revised by EC359060 and EC359114 .
5.3.2 1 E-1 (2)-4707AA, "Wiring Diagram Analog Input Cabinet 1(2}C91-P607 AlTs 1,2,3,4 Left Side," as revised by EC359060 and EC359114 .
5.4 VENDOR PRODUCT INFORMATION 5.4.1 Minco@ Quotation 160056-2, January 26, 2006 5.4.2 Minco@ Drawing S100995, dated 4/27/99 5.4.3 E-mail from Keith Johnson or Minco@ to Vikram Shah of LaSalle dated 7/25/06 5.4.4 ifm efector6008 TR2432 Operating Instructions, 701724/01, dated 02/04 5.4.5 Letter from Ameera Shah of ifrn efector to Vikrarn Shah of LaSalle dated 7/26/06 5.4.6 Fluke@ 45 Dual Display Multimeter Users Manual, Revision 4, dated 07/97 5.4.7 HP 34401A Multimeter User's Guide, Edition 4, printed February 1996 5.4.8 SOLAO SDN Power Supplies Specifications for SDN 2 .5-24-100P 5.4.9 RTP@ 8436 Series Analog Input Cards Technical Manual, 981-0021-211A, Rev. A, dated 04-96 5.4.10 Minco Report of Calibration for Platinum RTD, Model S100995PD, Serial No. P/N366 5.5 OTHER REFERENCES 5.5.1 LaSalle Technical Specifications, Sections 3.7.3, B 3.7.3, Amendments 178/164 5.5.2 LaSalle UFSAR, Rev. 16, Tables 3.11-18 and 3.11-24 5.5.3 EPRI TR-103099, "Effects of Resistance Temperature Detector Aging on Cross-Calibration Techniques," Final Report dated June 1994
CALCULATION PAGE NO. 1"003230 Revision 000 PAGE NO. 7 of 14 CALCULATION CALCULATIONS
&I RTD ERRORS (MODULE 1) 6.1 .1 Random Errors al 6.1 .1 .1 RTD Reference Accuracy RAI The RTD Reference Accuracy is +/-0.20F (Section 4.1 .1) . This is a 2a value.
RA1 2,, 0.2"F / 2 RAI 0.1 °F 6.1 .1 .2 RTD Calibration Error CALI The RTDs am not separately calibrated . Therefore, there is no calibration tolerance for this module . (The loop calibration tolerance is applied to Module 2, which is the module that is adjusted during loop calibration .)
CAL1 = 0 6.1 .1 .3 RTD Setting Tolerance ST1 The RTDs are not separately calibrated . Therefore, there is no setting tolerance for this module .
(The loop calibration tolerance is applied to Module 2, which is the module that is adjusted during loop calibration.)
ST1 0 6.1 .1 .4 Random Input Errors al in The RTDs are the first modules in the loop. Therefore, al in 0 6.1 .1 .5 , Drift Error DI The RTD Drift value (IDE) specified by the vendor is +/- 0.1 Wyear. [2a] The RTDs are not separately calibrated : RTD cross-calibration is performed to identify if an RTD has experienced significant drift . For conservatism the vendor's drift value will be expanded using the loop calibration interval (Section 4 .1 .1), The interval for these indicating loops is 4 years. The 25% late factor is 1 year. (VDP is the vendor drift period, or 1 year in this case.)
D 1 2, [IDEJ x [(SI + LF)NDp)]112
[0.1 F] x [(4 years + 1 year)/1 year]' /'
0.1 0 F x 2.236 0.2240F D1 0.112°F 6 .1 .1 .6 RTD Random Error (71 cri +/- [(RA1 n)2 +(CAL1 )2 +(ST1 )2 +(all in)2 +{D1)2]1/2
+/- [(0 .1 °F)2 + (0)2 + (0)2 + (0)2 + (0 .112)2]1/2
+/- 0.150 'F (11 +/- 0.150 'F
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO. 8 of 14 6.1 .2 Non-Random Errors Eel RTDs are passive devices that produce a resistance signal proportional to temperature .
affected As such, they are not by the following non-random effects .
Humidity Effects : eHl = 0 Static Pressure Effects : eSP1 = 0 Ambient Pressure Effects : ePl = 0 Power Supply Effects : eVl = 0 Seismic Effects : eS1 = 0 Effects Radiation : eR1 = 0 Process Effects: ePrl = 0 6.1 .2.1 Insulation Resistance Errors eIRl Insulation Resistance error is to be evaluated where actuation functions are expected to operate in an abnormal or harsh environment (Section 2.7) . There are no terminal blocks in 100% relative humidity areas, therefore, eIR1 0 6.1 .2.2 Resistance Drop of the Extension Wire eRD1 Since the RTD extension wires are made of the same material as the RTD itself, there is no emf rise or drop across the RTD head terminals (Section 4.2) eRDl = 0 6.1-2.3 Temperature Errors eTl RTDs are designed to exhibit a precise temperature effect that is used to develop the input signal to the loop. Since the RTDs are designed to function at temperatures well above the system design temperature, there is no temperature error other than the reference accuracy error. Therefore, eT1 0 6.1 .2.4 Non-Random Input Errors el in The RTD is the first module in the loop . Therefore, el in 0 6.1 .2.5 Non-Random Error Eel Eel eHl + eSPI + ePl + eVl + eSl + eRl + eTl + eIRl + ePrl + eIR1 + eRD1 + elfin 0+0+0+0+0+0+0+0+0+0+0+O=O'F Eel O'F 6.2 TEMPERATURE TRANSMITTER ERRORS (MODULE 2) 6.2.1 Random Error a2 6.2.1 .1 Reference Accuracy RA2 Reference Accuracy is 0.540F (Section 4.1 .3) . This is a 3a value .
RA2 0.54'F / 3 1 0.18°F
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO. 9 of 14 Per Reference 5.4.5, this accuracy includes drift and is warranted for 2 years. The calibration interval is 4 years . The 25% late factor is 1 year. (VDP is the vendor drift period, or 2 years in this case.) The formula for applying the surveillance interval to Drift will be applied to the entire RA2 error term .
RA2 +/- [IDE] x [(SI + LF)NDP)]"2
+/- [0.180 F] x [(4years + I year)/2 years)f
+/- [0.18 0 F] x [1 .581139]
RA2 :t 0.285'F 6.2 .1 .2 Calibration Error CAL2 The loop is calibrated using a variable resistance input, measured with a Fluke 189 DMM, and reading the indicated temperature at the PPC .
6.2.1 .2.1 Measurement & Test Equipment Error MTE2 H01 34401 Reference Accuracy is the manufacturer's accuracy (10.01% reading + 0.001% of range for the 1 k92) as a 2a value (Section 5.4.6) . The highest reading of interest is 101 .5'F. The Minco calibration reports for the RTDs show that the highest resistance value for this temperature is 115.0130 . (Section 4.1 .2)
RAMTE N, 0.01 % x 115.01352 + (0.00001 x 100052}
=10 .011552+0 .0152=0 .021552 0.0215Q x 1 OF/0.21492 = 0.100°F RAMTE2 = :t 0.050OF The manufacturer also specifies a Temperature coefficient for this range (1 kn) for OOC to 180C and 280C to 550C as 0.0006% of reading + 0.0001% of range per °C. The normal turbine building ambient temperature in the zone where the transmitter is installed varies from 830F to 1020F(Ref. 5.5 .2) . For additional conservatism, this range is expanded to 75OF to 1020F (or 23.90C to 38.90C). The lower temperature (23 .90C) is within the range where the coefficient is not applicable, so the applicable AT is: (38 .90C - 280 C) or 10.91C TEMTE22, =1(0.0006% x 115 .0130) + (0.000001 x 10000)
=+/-0.0006952 +0.001Q=+/-0.001690
= +/- 0.0016952 x 1 F/0.2140 = 0.00789O F O
RAMTE2 = :t 0.00395OF The temperature error is a degradation of the specified accuracy and is not considered an additional random error. Therefore, the total M&TE error for the H P 34401 A is:
MTE2 = +/- f(O .0500F)2 + (0.00395-F)2]1,'2 MTE2 = +/- 0.0502'F Fluke 45 (medium speed)
Reference Accuracy is the manufacturer's accuracy [1(0 .05°I° reading + 2 LSD + 0.02Q)] as a 26 value (Section 5.4.6) . [The LSD for the Fluke 45 is 0.01Q.] The highest reading of interest is 101 .5'F. The Minco calibration reports for the RTDs show that the highest resistance value for this temperature is 115.0130. (Section 4.1 .2)
RA2, = 1(0 .05% x 115 .0130) + [(2 x 0.0152) + 0.020]
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO. 10 of 14 0.057592 + 0.040 = 0.097592 0.097592 x 1 "F/0.2140 = 0.456c F MTE2 = :t 0.228'F The Fluke 45 (med . speed) M&TE error is bounding and will be used to evaluate total loop uncertainty .
6.2.1 .2.2 Calibration Standard Error STD2 The calibration standard error is evaluated as negligible (Section 3.2) .
STD2 = 0 6.2.1 .2.3 Loop Calibration Tolerance ST2 The calibration tolerance for this indicating loop is +/- 0.540F (Section 4.7) . [3(y]
ST2 +/- 0.540 F / 3 ST2 +/- 0.18OF 6.2.1 .2.4 Calibration Error CAL2 The total calibration error for the M&TE is:
CAI 9 +/- [(MTE2)2 + (STD2)2 + (ST2) 2]'i2
+/- [(0 .228'F)2 + (0)2 + (018)2]' 2 CAL2
- 0.29'F 6.2.1 .3 Ambient Temperature Error crT2 The vendor states the "temperature drift" error for the temperature transmitter as O.i°l° of measuring range / 100C (Ref. 4.1 .3) [3a] . This is applied in this calculation as an ambient temperature error. Measuring range: 30 to 120'F = 90'F.
The normal turbine building ambient temperature in the zone where the transmitter is installed varies from 830 F to 1020F(Ref. 5.5.2) . For additional conservatism, this range is expanded to 750F to 102'F (27'F difference) .
(YT2 * (0.1%
- Span)
- [(0 .001
- 900F)/10 0C x (270F x 5°F/8°C) 10.1519°F/3 6T2 t 0.051 *F 6.2.1 .4 Random Input Error a2in o2lin cyl :t 0.160'F 6.2.1 .5 Power Supply Effects o2PS The transmitter specifications are valid for voltages between 20 and 30 vDC. The 24-volt power supply variability is less than 2% all errors combined (4.3) . This is equal to 23.5vDC to 24.5vDC. Therefore, o2PS = 0 'F 6.2.1 .6 Total Random Error cr2
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO. 11 of 14 (72 +/- [(RA2)2 + (CAL2 )2+ ((TT2)2 + ((y2in)2 + (a2pS)2]112 62 +/- [(0 .285'F) 2 + (0.2900F) 2 + (0.051 -F) 2 + {0.150°F)2 + (00F)2f/2 o2 :t 0.436F 6.2.2 Non-Random Error Eel 6.2.2.1 Humidity Error e2H No humidity effect errors are provided in the manufacturer's specifications, and the humidity conditions at the instrument location are within the operating limits of the module . Humidity errors are negligible during normal conditions. (Reference 5 .1 .2, Appendix 1) e2H = 0 6.2.2.2 Radiation Error e2R No radiation errors are provided in the manufacturer's specifications . Per Section 2.8, it is reasonable to consider the normal radiation effect as negligible. Therefore, e2R = 0 6.2.2.3 Seismic Error e2S No seismic effect errors are provided in the manufacturer's specifications . A seismic event defines a particular type of accident condition . Therefore, there is no seismic error for normal operating conditions e2S = 0 6.2.2.4 Static Pressure Offset Error e2SP The transmitter is an electrical device and therefore not affected by static pressure.
e2SP = 0 6.2.2 .5 Ambient Pressure Error e2P The transmitter is an electrical device and therefore not affected by ambient pressure.
e2P = 0 6.2.2.6 Process Error e2Pr The transmitter receives an analog input from an RTD . Any errors associated with the conversion of temperature to resistance have been accounted for as RTD errors . Therefore, e2Pr = 0 6.2.2.7 Non-Random Input Error e2lin eNn = 101 = 0 6.2.2.8 Total Non-Random Error 1e2 Eel e2H + e2R + e2S + e2SP + e2P + e2Pr + e2in 0+0+0+0+0+0+0 Eel 0 6.3 PPC 110 MODULE ERRORS (MODULE 3)
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO . 12 of 14 6.3.1 Random Error a3 6.3-1 .1 Reference Accuracy RA3 Reference Accuracy is +/- 0.025% calibrated range (Ref. 5.4.9) . The calibrated range is 30OF to 120-F (120OF - 30OF = 900F) .
RA321 +/-0.00025 x 90OF = 0.02250F RA3 10.0113°F 6.3.1 .2 Calibration Error CAL3 The 1/0 module is not separately calibrated ; indication is verified during loop calibration, CAL3 = :tO'F 6.3.1 .3 Drift Error D3 The vendor does not specify a drift error specification for the 1/0 module .
D3 :t O'F 6.3.1 .4 Random Input Error cr3in a3in a2 0.437*F 6.3.1 .5 Total Random Error 0 Q = +/- RRA3)2 + (CAL3 )2 + (6D3)2 + (a3in) 2+ {63r}2}1/2 a3 = +/- [{0 .0113°F)2 + (0.0-F)2 + (0-F)2 + (0.4360F)2]112 03 =
- 0.436*F 6.3.2 Non-Random Error 1e3 6.3-2.1 Humidity Error e3H No humidity effect errors are provided by the manufacturer' ; specified RH for PPC equipment is 20 to 80% RH. The 1/0 module is located in EQ Zone C 1 A, (Section 4.6), where expected RH levels are 20 to 50%. Humidity errors are negligible. (Reference 5.1 .2, Appendix 1) e3H = 0 6.3.2.2 Radiation Error e3R No radiation errors are provided in the manufacturer's specifications . Per Section 2.8, it is reasonable to consider the normal radiation effect as negligible. Therefore, e3R = 0 6.3-2.3 Seismic Error e2S No seismic effect errors are provided in the manufacturer's specifications . A seismic event defines a particular accident condition . Therefore, there is no seismic error for normal operating conditions e3S = 0 6.3.2.4 Static Pressure Offset Error e3SP
CALCULATION PAGE CALCULATION NO. L-003230 Revision 000 PAGE NO . 13 of 14 1
The 1/0 module is an electrical device and therefore not affected by static pressure.
e3SP = 0 6.3.2.5 Ambient Pressure Error e3P The 1/0 module is an electrical device and therefore not affected by ambient pressure .
e3P = 0 6.3.2.6 Process Error e3Pr The 1/0 module receives an analog current input from the transmitter . Any errors associated with the conversions of temperature to resistance, and resistance to current have been accounted for as errors associated with modules 1 and 2. Therefore, e3Pr = 0 6.3.2.7 Input Signal Resistor Error e3SR e3SR (0.02% Span) (Section 4.4) 0.0002 90OF 0.018 'F e3SR =t 0.018'F 6.3.2.8 Non-Random Input Error e31n eAn = 102 = 0 6 .3.2.9 Total Non-Random Error Ye3 1e3 = e3H + WR + e3S + e3SP + e3P + e3Pr + e3SR + eln
=0+0+0+0+0+0+0.018+0 10 = 0.018 6.4
SUMMARY
AND CONCLUSION (TOTAL ERROR) 6.4.1 As discussed in Methodology Secti 2.2, bevel 2 methodology is applied for determining Total Error for this indication loop:
TE a3 + 1e3
" (0-436'F)+ 0.018°F
" OA54OF TE t 145FF In conclusion, the total uncertainty for the CW Inlet Temperature Indication loop is +/- 0.4540F 6.4.2 To obtain a more accurate value of the LIHS temperature using these instruments, the average of the available values can be taken . This assumes that the four readings are sensing the same input temperature and that there is little effect between the input and the measurement point.
- TITE-CWOIO+TTE-cwot,+T2TE-cwoio + T2TE-CW011 TCWAverage 4
CALCULATION PAGE CALCULATION NO. L-OQ323Q Revision OQQ PAGE NO. 14 of 14 The accuracy of this process is considered the same as the accuracy of summing networks addressed in References 5.1 .1 and 5.1 .2, or by the multiple test criterion of Reference 5.1 .4 Section 3.2.
In all of these cases the final random uncertainty (6) is the square root sum of the squares of the individual channel random uncertainties considering the multiplier for each of the uncertainties is one divided by the number of channels that are being averaged. The non-random uncertainty (e) will remain the same as for a single loop (Ref. 5.1 .4, Section 3.2).
r
~nT~n+nj+*~n )~
If all of the instrument loops are identical then this equation will reduce to:
B Average 4_n +
Thus for the CW temperatures, the accuracy of the average of the readings far two loops will be:
_ 0.436
+e=0.30$+0.018=0.326°F 2
Average (-
The accuracy of the average of the readings for three loops will be:
- 0~6 Average
+e=0 .252+0.018=0.270°F The accuracy of the average of the readings for four loops will be:
,~ 0.436 Lf Average =+e=0.218+0.018=0 .236°F
7300 Commerce Lane C
Minneapolis, MN 55432 U.S.A.
Customer Service Telephone : 763-571-3123 Sales Inquiries Fax : 763-571-0927 Purchase Order Fax : 763-571-0942 A critical component of your succesf E-Mail : custserv@minco .co m QUOTATION To: Vikram Shah Quote No: 160056-2 Exelon Corporation Page: 1 LaSalle County Nuclear Station Date: January 26, 2006 2601 N 21st Marseilles Road RFQ: RTD Assemblies Marseilles IL 61341-9757 Phone: 815-415-3828 CC: Thermo/Cense, Inc.
Fax: 942 Turret Court Mundelein, IL 60060 Fax Order to 763-571-0942 or Phone : 847-949-8070,8071 E-Mail Order to custserv@minco.com Fax : 847-949-8074 Please Reference Above Quote Number When Placing Your Order.
L Description uantity 1 Minco Part # ASSEMBLY ^ 1-9!
Assembly Consisting Of: I I
CGASSY CH359P2T6 FG113-1 FG750F8MI2 XS853PD157X4 i
v
= Class A sensor.
Single Element_RTD assembly____
2 Minco Part # XRT07 i 1 - 9I 425.00 Test charge for a chart of temperature readings at . 1F intervals from -272F to 932F Notes :
1 . These assemblies will replace the existing head that is on the thermowell . This is due to not knowing how long the replacement probe would need to be. The drawing does not provide all of this information to determine the proper length. Lead time for these parts is also relatively short as compared to a special probe .
- 2. 1 . Probe length is 15.6" . This is the necessary length of the probe to fit in the thermowell and fit into the connection head .
- 2. The probe diameter is .25", but will fit in the thermowell without any reduction in performance .
3 . Drift specifications on the 5852 sensor is listed as +/- .2 F per year, repeatability is also +/- .2 F. This specification assumes cycling throughout the full temperature range of the sensor, from -
50C to 260C. A smaller temperuture cycle will change the amount of drift.
D Slo 5 5100995 SPECIFICATIONS DRAWING NUMBER .
PD SENSING ELEMENT:
PD = 100 OHM +/- .06%, .00385 PLATINUM, 48 CASE LENGTH A IN .1' INCREMENTS (48 = 4.8") .
MINIMUM A 28 (2 .8") (71) ;
MAXIMUM A 480 (48.0') [12191 .
z NUMBER OF LEADS:
Y = 2 LEADS; Z 3 LEADS; X 4 LEADS .
36 LEAD LENGTH 8 IN INCHES .
r B (D A *36
[+/-1 .5]
48 0.260
- (065 .351 U.
STRIP
.5 [13] MIN SLEEVE 0
SCHEMA= DIAG nuw 1 . ELEMENT: PLATINUM .
0 0C" .1A .P . - - I- A-b- 2-LEAD MODEL 3-LEAD MODEL 4-LEAD MODEL Q V,27),
(3 EXCLUDING LEADWIRE RESISTANCE ; RIT TABLES #5-100 (*C) AND
- 6-1 00 (T).
- 3. RESISTANCE-TEMPERATURE COEFFICIENT : .00385 OHM/OHM/'C NOMINAL FROM O'C TO 100'C.
- 4. TEMPERATURE RANGE: -50'C TO 260'C (-58*F TO 5001F) .
- 5. INSULATION RESISTANCE : 1000 MEGOHMS MINIMUM AT 500 VOLTS DC, YELLOW WHITE YELLOW LEADS TO CASE WHITE (2) YELLOW (2) WHITE (2)
- 6. LEADS: AWG #22, STRANDED, TFE INSULATED, (D TOLERANCE ON LEAD LENGTH : UNLESS OTHERWISE SPEC DIMENSIONS AND TOLERANCES IN INCHES 71" (18031 AND UNDER: +2/-0" [+511-0] ; DIMENSIONS IN [ j ARE IN 1AILUMETUM 72' TO 119" [1829 TO 3023): +4/-0" [t102/-O) ; ONE PLACE (.0) *.020 [*0.51) 120" (3048) AND OVER : +6/-0" [+1521-0] . TWO PLACE (.00) 1 .010 .131
[*o251
- 8. CASE : STAINLESS STEEL, COPPER ALLOY TIP. THREE PLACE (.000) moos RESISTANCE THERMOMETER ANGLES :
CASE MAY BE CUT TO SHORTER LENGTH . USE CARE NOT TO DAMAGE PROBE TYPE, TIP-SENSITFVE LEADWIRE INSULATION . LOCATE THE SLIP-FIT TFE SLEEVE IN END OF CUT-OFF CASE TO PROTECT LEADWIRE INSULATION AT POINT OF S100995 SERIES EMERGENCE. MINIMUM A FOR CUT-OFF CASE IS 28 (2,8') [71] .
THE RESISTANCE THERMOMETER WILL MEET THE RESISTANCE-TEMPERATURE RELATIONSHIP AND TOLERANCES SPECIFIED IN IEC 751, CLASS A.
Print Date : 07/28/2006 10 :12
VanWyk, Thomas J.
From :
Sent:
To :
Keith Jensen [Keith.Jensen@minco.com]
Wednesday, July 26, 2006 9:22 AM Shah, Vikrarn R.
E C1 Rev. 5 U003230 Attachment P g (I C LPage (S I (hnal)
Subject:
Fwd: Exelon Corporation 100995,pdf
>>> Keith Jensen 7/25/2006 3 :50 PM >>>
Vikram Shah 815-415-3828 Exelon Corporation Marsailles IL vikram .shah@exelon .com XS853PD157X4 RFQ 160056-2 The S100995 probe meets the EN60751 Class A +/- 0 .06% @ OC sensor accuracy requirements Minco estimates the drift per year over the range of 30F to 120F would be expected to be around OAF or less (PHP)
The drawing is attached Keith Jensen 763-586-2908 Applications Engineer MINCO PRODUCTS INC .
Minneapolis MN keith .jensen@minco .com
L-(1032 3 0 Attachment D Page D1 Bedienungsanleitung Operating instructions Notice utilisateurs efI-2ICLor1S9i Auswerteelektronik fur Temperatursensoren Control monitor for temperature sensors Amplificateur pour sondes de temperature TR2432
L-003230 Rev. 0 Attachment D Page 1)2 (final)
Technical data Operating voltage [V] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 . . . 30 DC 1)
Current rating [MA]
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 Short-circuit prot., reverse polarity prat. / overload prat.,
watchdog Voltage drop N] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . : . . . . . . . . .. . . < 2 Current consumption [MA] . . . . . . . . . . . . . . < 552)
Constant current sensor [MA] . . . . . . . . . . * * . * . * . * . * . * . . .. .0.2
. . .(Pt
. . 1000
. element)
Constant current sensor [MA] . . . . . . . . . . . . . . . . . . . 2.0 (Pt 100 element)
Power-on delay time [s] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 .5 Response time switching output [ms] . . . . . . . . . . . . . . . . . . . . . . . . . 130 Analogue output (measuring range scaleable) . . . . . . 4 . .. 20 mA 0 .. . 10V Max. load current output [S)] . . . . . . . . . . . (U8 - 10) x 50; 700 at UB = 24 V Min. load with voltage output [0] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 Response time analogue output [ms] . . . . . . . . . . . . . . . . . . . . . . . . . . 3841 Accuracy Switching output [°C-1°F]
.. . . . . . . . . . . . . . . . . . . . . . . . . . .
- 0.3 /
- 0.54 I Analog output [0C/0F] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- 0 .31 +/- 0 .54 /
Display [IC/°F] . . . . . . . . . . . . . . . . . . . . . . . . . . . +/- (0.3 0.54 + Y2 Digit)
Resolution Switching output [0CrF] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1/0.1 Analogue output [0C/0F] . . . . . . . . I . . . . . . . . . . . . . . . . . . . . . . . 0.1/0 .1 Display [IC/IF] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1/0.1 Temperature drift [% 4 value of measuring range(l 0 K] . . . . . . . . . . . +/- 0.1 Housing material stainless steel {304S15); EPDM/X (S- antoprene) ;
PC (Macrolon); Pocan; FPM (Viton)
Operating temperature [OC] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 .. .+70 Storage temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 ...+85 Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 67, 111 Insulation resistance [MQ] . . . . . . . . . . . . . . . . . . . . . . . . > 100 (500 V DC)
Shock resistance [g] . . . . . . . . . . . . . . . . . . 50 (DIN / IEC 68-2-27, 11 ms)
Vibration resistance [g] . . . . . . . . . . . . . 20 (DIN , * / IEC 68-2-6, 10 - 2000 Hz)
EMC EN 61000-4-2 ESD: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4/8 KV EN 61000-4-3 HF radiated: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 V/m EN 61000-4-4 Burst: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 KV EN 61000-4-6 HF conducted: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10V to EN50178, SEW, PEU, referring to UL see page 21 (Electrical connection).
- 2) 41 mA when the display is switched off; the values apply to the operating voltage = 24 V and unloaded outputs.
29
L-003230 Rev. 0 Attachment E Page E I (final)
[gliale Dmv, PA 19341 # # Nw 800-329-0436 0 vvtoozi July 26, 2006 Mr. Vikram Shah Exelon Corporation 2601 N 21 st Rd .
Marseilles, Illinois 61341
Dear Vikram:
This letter is in response to your concern about the specifications of the ifm efector TR2432 temperature sensor. The following points should clarify the questions that you had :
" After production, 100% of the sensors are verified and tested to the specifications listed on our datasheet.
" The analog accuracy specification of (+/- 0.540F) already includes the analog resolution value of (0 .1'F), and is inclusive of any electronic component drift.
" The temperature drift specification is the electronic drift that occurs for every 10°C change in temperature that occurs in the application . This drift is in addition to the accuracy specification.
" There are no other environmental influences that will affect the accuracy specification.
" These sensors have a warranty period of 2 years.
Phase contact me if you have any further questions, or if you require any additional information .
Best regards, Arneera Shah Product Support Engineer Fluid Sensors Team
SPECIFICATIONS - OHMS L-003230 Rev . 0 Attachment F Attachment F: Fluke 45 Accuracy Specifications .Page F1 (final OHMS Resolution Typical Full Max Current Range Accuracy Full Scale Through the Slow Medium Fast Voltage Unknown 3000 - 10 MO 100 M0 0.05% + 2 + 0.020 0.25 1 mA 3 k0 - 100 M0 10 0.05%+2 0.24 120 yA 30 kn - 10 100 0,05%+2 0.29 14,uA 300 kO - 100 10012 0,05%+2 0.29 1 .5,uA 3 MO - 1000 1 kO 0.06%+2 0.3 150 pA 30 M0 - 1 kO 10 kO 0.25%+3 2.25 320 pA 300 MO* - 100 kO 1 M0 2% 2.9 320 pA 1000 1 m0 - - 0.050/b + 8 + 0.0212 0.09 1 mA 100012 10 m0 - - 0.05% + 8 + 0.0212 0.10 120 /pA 101<0 100 mfg - - 0.05%+8 0.11 14 NA 100 kit 1n - - 0.05%+8 0.11 1.5 pA 1000 kn 100 - - 0.06%+8 0.12 150 fjA 10 Mn 1000 - - 0.25%+6 1.5 150 pA 100 MO* 100 kn - - 2%+2 2.75 320 fjA
- Because of the method used to measure resistance, the 100 Mn (slow) and 300 Mil (medium and fast) ranges cannot measure below 3.2 Mil and 20 MO, respectively. "UL" (underload) is shown on the display for resistances below these nominal points, and the computer interface outputs "+1 E-9".
Open Circuit Voltage 3.2 volts maximum on the 1000, 3000,30 M0,100 MID, and 300 M0 ranges, 1 .5 volts maximum on all other ranges .
Input Protection 500V do or rms ac on all ranges
L-003230 Rev. 0 chnient G age Gl (final)
SDN TM Specifications (Single Phase)
Catalog Number Description SON 2.5-24-100P SON 4-24-t00LP SON 5-24-100P' SDN 10-24-100P SON 20-24-100P Input Nominal Voltage 115/230 VAC auto select
-AC Range 85-1321176-264 VAC
-DC Range'90-375 VDC 210-375 VDC N/A
-Frequency 47 - 63 Hz Nominal Current' 1 .3A,10 .7A 2 .1A11 .0A 2.2A/1 .0A 5A12Atyp . 9A/3 .9A
-inrush current max . typ. < 25 A typ . < 20 A typ. < 40 A Efficiency (Losses') > 87 .5% typ (8.6 W) > 88% typ (13 .1 W) > 68%typ (16.4 W) > 88% typ (32 .7 W) > 90% typ (48 W)
Power Factor Correction Units Fulfill EN61000-3-2 Output Nominal Voltage 24 VDC (22 .5 - 28 .5 VDC adj .) 24 VDC (22.5 - 25 .5 VDC adi.) 24 VDC (22.5 - 28.5 VOC adi .)
-Tolerance < t2% overall (combination Line, load, time and temperature related changes)
-Ripple' < 50 mvpP Nominal Current 2.5A(60W) 18A(92W) 5A(120W) 10A(240W) 20A(480W) 1 .6x Nominal Current 6 A 2x Nominal Current 12 A 2x Nominal Current 25 A 2x Nominal Current
-Peak Current' 4 .2 A max at 23 .8V
< 2 sec. < 2 sec. < 2 sec . < 2 sec .
-Current Limit Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)
Holdup Tuna' > 50 ms > 100 ms > looms > 20 ms Parallel Operation Single or Parallel use is selectable via Front Panel Switch (SDN4 should not be used in parallel as Class 2 rating would be violated .)
General EMC :
EN61000-6-3, -4 ; Class B EN55011, EN55022 Radiated and Conducted including Annex A .
-Emissions EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 level 3 ; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class
-Immunity 4, EN61000-4-11 ; Transient resistance according to VDE 0160/W2 over entire load range .
EN60950 ; EN50178; EN60204 ; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93168/EEC) . EN61000-3-2, IEC60079-15 (Class 1, Zone 2, Hazardous Approvals Location, Groups A, B, C, D w/ T3A temp class up to 60'C Ambient.) SEMI F47 Sag Immunity. SON2.5 & SDN4 - UL60950 testing to include approval as Class 2 power supply.
Storage : -250C . . +/-850 C Operation. -100-60 00 full power with operation to 700C possible with a linear derating to half power from 600 C to 700C (Convection cooling, Temperature no forced air required) . Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative humidity is < 90% RH, noncondensing; IEC 68-2-2, 68-2-3. For operation below -10 00, contact Technical Services .
MTSF: > 820,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> > 640,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> > 600,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> > 510,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />
- Standard Bellcore Issue 6 Method 1 Case 3 @ 40C MIL217F Q 30C Warranty 5 years Protected against continuous short-circuit, overload, open-circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529)
General Protection/Safety Safe low voltage: SELV (acc.EN60950)
Status Indicators Green LED and DC OK signal (N .O . Solid State Contactrated 200 mA 160 VOC)
Installation Fusing Internally fused. External 10 A slaw acting fusing for the input is recommended to protect input wiring.
-Input Outputs are capable of providing high currents for short periods of time for inductive load startup or switching . Fusing may be required for wire/loads if 2x Nominal
-Output O/P current rating cannot be tolerated . Continuous current overload allows for reliable fuse tripping .
Mounting Simple snap-on system for DIN Rail TS35(7,5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).
Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1 .5-6 mm2) for solid conductors. 16-12 AWG (0 .5-4 mm2) for flexible conductors .
Connections Output: Two connectors per output, connector size range: 16-10 AWG (1 .5 - 6 mm2) for solid conductors .
Fully enclosed metal housing with fine ventilation grid to keep out small parts .
25 mm above and below, 25 mm left and right, 25 mm above and below, 25 mm 70 mm above and below, 25 mm left and right,
-Free Space 10 mm in front left and right, 15 mm in front 15 mm in front 4 .88 in . x 1 .97 in . x 4 .55 in. 4 .88 in. x 2.56 in . x 4 .55 in . 4 .88 in . x 3 .26 in . x 4 .55 in . 4,88 in . x 6.88 in . x 4 .55 in.
H x W x D {(ncheslmm) (124 mm x50 mm x116 mm) (124 mm x65 mm x116 mm) (124mmx83mmx116mm) (124mmx175mmx116mm)
Wetght ((bslg) 1 lb (460g) 1 .5 Ibs (620g) 2 .2 Ibs (1100g) 3 Ibs (1520g)
Input current ratings are conservatively specified with low input, worst case efficiency and power factor. ` All peak current is calculated at 24 Volt levels.
Losses are heat dissipation in watts at full load, nominal input tine. ' Full load, 100 VAC Input § Tam =+25" C Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. ° Not UL listed for DC input.
Visit our website at www.solaheviduty.com or contact Technical Services at (800) 377-4384 with any questions .
L-003230 Rev. 0 8436/32 8-Channel Isolated Low-Level Analog Input Card Attachment H Page III (Anal) 8436/32 8-Channel Isolated Low-Level Analog Input Card The RTP8436/32 8-Channel Isolated Analog Input Card provides high accuracy low-level
(+/-160 mV) analog measurements . Sampling transformers provide channel-to-channel isolation . Very high noise immunity is characteristic of the transformer multiplexer, achieving 160 dB of common mode rejection . Immunity to noise is further enhanced with a two-pole low pass filter, set to provide 70 dB of normal mode rejection at 60 Hz.
Analog to digital conversion is performed by a 16-bit switched capacitor successive approximation AID converter . A precision voltage source provides a self-test function for the card's amplifiers and A/D converter . No field adjustments are necessary after the initial factory setup .
Specifications Input Signal Range: +/- 160 mV Multiplexer Type: 8-channel solid state multiplexer with individual transformers for complete channel-to-channel isolation Sample Rate: 50 samples per second per channel Accuracy: 0.025% of Full Scale Temperature Ranges : -25' to +850C (-130 to +185'F), storage 0* to +55oC (+320 to +131°F}, standard operating
-20* to +600C (-4* to +140'F), extended operating Note: Input measurements may not meet the accuracy specification at the upper or lower ends of the extended operating range.
Isolation : 600 VAC RMS or 400 VDC
- 1500 VAC @ 60 Hz for 60 seconds withstand Common Mode Voltage : 600 VAC RMS or 400 VDC continuous Common Mode Rejection : -160 dB at 60 Hz (10052 unbalanced)
Common Mode Crosstalk : -150 dB at 60 Hz Normal Mode Rejection : 2-pole low pass filter, -70 dB at 60 Hz Input Impedance: 5 Mf2 in parallel with 10 pF at 50 samples/second per channel Input Bias Current: 8 nA maximum at 50 samples/second per channel Input Source Impedance : 10052 maximum to meet accuracy specification
L-003230 Rev. 0 Attachment I Page 11 Report of Calibration for Platinum Resistance Thermometer Model S100995PD Serial No . P/N366
L-003230 Rev. 0 1 Attachment i 1 11521--A Pag; 12 (final) !
TOM R(ohms) TOO R(ohms) T('F) R(ohms) T()F) R(ohms) 100 .0 114 .692 105 .0 115 .762 110 .0 116 .832 115 .0 117 .901 100 .1 114 .713 105 .1 115 .784 110 .1 116 .854 115 .1 117 .922 100 .2 114 .735 105 .2 115 .805 110 .2 116 .875 115 .2 117-944 100 .3 114 .756 105 .3 115 .827 110 .3 116 .896 115 .3 117 .965 100 .4 114 .777 105 .4 115 .848 110 .4 116 .918 115 .4 117 .986 100 .5 114 .799 105 .5 115 .869 110 .5 116-939 115 .5 118 .008 100 .6 114 .820 105 .6 115 .891 110 .6 116 .961 115 .6 118 .029 100 .7 114 .842 105 .7 115 .912 110 .7 116 .982 115 .7 118 .051 100 .8 114 .863 105 .8 115 .934 110 .8 117 .003 115 .8 118 .072 100 .9 114 .884 105 .9 115 .955 110 .9 117 .025 115 .9 118-093 101 .0 114 .906 106 .0 115 .976 111 .0 117-046 116 .0 118 .115 101 .1 114 .927 106 .1 115 .998 111 .1 117 .067 116 .1 118 .136 101 .2 114 .949 106 .2 116 .019 111 .2 117 .089 116 .2 118 .157 101 .3 114 .970 106 .3 116 .041 111 .3 117 .110 116 .3 118 .179 101 .4 114 .992 106 .4 116 .062 111 .4 117 .132 116 .4 118 .200 101 .S 115 .013 106 .5 116 .083 111 .5 117 .153 116 .5 118 .221 101 .6 115 .034 106 .6 116 .10S 111 .6 117 .174 116 .6 118-243 101 .7 115 .056 106 .7 116 .126 111 .7 117 .196 116 .7 118 .264 101 .8 115 .077 106 .8 116 .148 111 .8 117 .217 116 .8 118 .286 101 .9 115 .099 106 .9 116 .169 111 .9 117-238 116 .9 118,307 102 .0 115 .120 107 .0 116 .190 112 .0 117 .260 117 .0 118 .328 102 .1 115 .142 107 .1 116 .212 112 .1 117 .281 117 .1 118 .350 102 .2 115 .163 107 .2 116 .233 112 .2 117 .303 117 .2 118 .371 102 .3 115 .184 107 .3 116 .255 112 .3 117 .324 117 .3 118 .392 102 .4 115 .206 107 .4 116 .276 112 .4 117-345 117 .4 118 .414 102 .5 115 .227 107 .5 116 .297 112 .5 117 .367 117 .5 118 .435 102 .6 115 .249 107 .6 116 .319 112 .6 117 .388 117 .6 118 .456 102 .7 115 .270 107 .7 116 .340 112 .7 117 .410 117 .7 118 .478 102 .8 115 .291 107 .8 116 .362 112 .8 117 .431 117 .8 118 .499 102 .9 115 .313 107 .9 116 .383 112 .9 117 .452 117 .9 118 .520 103 .0 115 .334 108 .0 116 .404 113 .0 117 .474 118 .0 118 .542 103 .1 115 .356 108 .1 116 .426 113 .1 117 .495 118 .1 118 .563 103 .2 115 .377 108 .2 116 .447 113 .2 117 .516 118 .2 118 .585 103 .3 115 .399 108 .3 116 .469 113 .3 117 .S38 118 .3 118 .606 103 .4 115 .420 108 .4 116 .490 113 .4 117 .559 118 .4 118 .627 103 .5 115 .441 108 .S 116 .511 113 .5 117 .580 118 .5 118 .649 103 .6 115 .463 108 .6 116 .533 113 .6 117 .602 118 .6 118 .670 103 .7 115 .484 108 .7 116 .554 113 .7 117 .623 118 .7 118 .691 103 .8 115 .S06 108 .8 116 .576 113 .8 117 .64S 118 .8 118 .713 103 .9 115 .S27 108 .9 116 .597 113 .9 117-666 118 .9 118 .734 104 .0 115 .S46 109 .0 116 .618 114 .0 117 .687 119 .0 118 .75S 104 .1 11S-S70 109 .1 116 .640 114 .1 117 .709 119 .1 118 .777 104 .2 11S-S91 109 .2 116 .661 114 .2 117 .730 119 .2 118 .798 104 .3 115 .613 109 .3 116 .683 114 .3 117 .751 119 .3 118 .819 104 .4 115 .634 109 .4 116 .704 114 .4 117 .773 119 .4 118 .841 104 .5 115 .655 109 .5 116 .725 114 .5 117 .794 119 .5 118 .862 104 .6 115 .677 109 .6 116 .747 114 .6 117 .816 119 .6 118 .883 104 .7 11S .698 109 .7 116 .768 114 .7 117 .837 119 .7 118 .905 104 .8 11S .720 109 .8 116 .789 114 .8 117 .858 119 .8 118 .926 104 .9 115 .741 109 .9 116 .811 114 .9 117 .880 119 .9 118 .947 105 .0 115 .762 110 .0 116 .832 115 .0 117 .901 120 .0 118 .969
Rev . 0 Attachment A P 34401 A Accuracy Speciffic-affilmns
= J
- ------J,Page L-0032ent Attach J I30 (final)
Chapter 8 Specifications DC Characteristics DC Characteristics Accuracy Specifications +/- ( % of reading + % of range ) [ 1 ]
Temperature Test Current or 24 How [ 2] 90 Day I Year Coefficient f°C Function Range 131 Burden Voltage 23'C +/- 1'C 23'C +/- 5'C 23'C +/- 5'C 01C -18°C 28'C - 55'C DC Voltage 100.0000 mV 0.0030 + 0.0030 0.0040 + 0,0035 0,0050 + 0.0035 0.0005 + 0.0005 1 .000000 v 0.0020 + 0.0006 0.0030 + 0.0007 0.0040 + 0.0007 0.0005 + 0.0001 10 . 00000 V 0.0015 + 0.0004 0.0020 + 0.0005 0.0035 + 0.0005 0.0005 + 0.0001 100. 0000 V 0.0020 + 0.0006 0.0035 + 0.0006 0,0045 + 0.0006 0.0005 + 0.0001 1000000 V 0.0020 + 0.0006 0.0035 + 0.0010 0.0045 + 0.0010 0.0005 + 0.0001 Resistance 100.0000 n 1 mA 0.0030 + 0.0030 0.008 + 0.004 0.010 + 0.004 0.0006 + 0 .0005
[ 4] 1 .000000 ko 1 mA 0,0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0006 + 0.0001 10 . 00000 kit 100 NA 0.0020 + 0.0005 0.006 + 0.001 0.010 + 0.001 0.0006 + 0.0001 100 .0000 ko 10 pA 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0006 + 0.0001 1 .000000 Mn 5 pA 0.002 + 0,001 0.008 + 0.001 0.010 + 0,001 0.0010 + 0.0002 10,00000 Mfg 500 nA 0.015+0.041 0.420 + 1001 0.040 + 2001 0.0030 + 0.0004 100.0000 Mid 500 nA 10 Mn 0.300 + 0.010 0.800 + 0.010 0.800 + 0.010 0.1500 + 0.0002 DC Current 10. 00000 mA < al V 0.005 + 0.010 0,030 + 0.020 0.050 + 0.020 0,002 + 0.0020 100.0000 mA <0 .6V 0.01 + 0.004 0.030 + 0.005 0.050 + 0.005 0.002 + 0.0005 1 .000000 A <1 V 0.05 + 4.006 0.080 + 0N0 0.100 + 0.010 0.005 + 0,0010 3.000000 A <2V 0.10+0.020 0.120 + 0.020 0.120 + 0.020 0.005 + 0.0020 Continuity 1000.0 n 1 mA 0.002 + ONO 0.008 + 0.020 0.010 + 0.020 0.001 + 0.002 Diode Test 1 .0000 V 1 mA 0.002 + 0,010 0.008 + 0.020 0.010 + 0.020 0.001 + 0.002 DC:DC Ratio 100 mV Input Accuracy + ( Reference Accuracy to Iwo V Input Accuracy= accuracy specification for the HI-LO input signal .
Reference Accuracy= accuracy specification for thel-11-1-0 reference input signal .
Transfer Accuracy ( typical )
hour % of range error Conditions :
2 - Within 10 minutes and +/- 0.5'C .
" Within +/-10% of initial value.
" Following a 2-hour warm-up.
" Fixed range between 10% and 100% of full scale.
1
" Using 6 /2 digit slow resolution ( 100 PLC ),
" Measurements are made using accepted metrology practices.