ML21271A199

From kanterella
Jump to navigation Jump to search
License Amendment Request (LAR) 21-01, Chapter 3 16 Omaha Public Power District, Offsite Dose Calculation Manual CAC 2
ML21271A199
Person / Time
Site: Fort Calhoun 
(DPR-040)
Issue date: 08/03/2021
From: Marcellus M
Omaha Public Power District
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21271A178 List: ... further results
References
LIC-21-0005
Download: ML21271A199 (124)


Text

Page 1 of 124 (Req Reviews: Rad Review, ISR, RP)

CH-ODCM-0001 Off-Site Dose Calculation Manual (ODCM)

Revision 37 Safety Classification:

Usage Level:

Non-Safety Reference Change No.:

EC 70719 Reason for Change:

Specify Restricted Areas and remove reference to withdrawn reg guide.

Preparer:

Matt Marcellus Fort Calhoun Station

CH-ODCM-0001 Reference Use Page 2 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table of Contents PART I 1.0 PURPOSE AND SCOPE................................................................................................. 6 1.1 Purpose..................................................................................................................... 6 1.2 Scope........................................................................................................................ 6 2.0 DEFINITIONS.................................................................................................................. 6 3.0 INSTRUMENTATION.................................................................................................... 10 3.1 Radioactive Liquid Effluent Instrumentation............................................................ 10 3.2 Radioactive Gaseous Effluent Instrumentation....................................................... 13 4.0 RADIOACTIVE EFFLUENTS........................................................................................ 17 4.1 Radioactive Liquid Effluents.................................................................................... 17 4.2 Radioactive Gaseous Effluents............................................................................... 23 4.3 Uranium Fuel Cycle................................................................................................. 29 5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP).................. 30 5.1 Monitoring Program................................................................................................. 30 5.2 Land Use Survey..................................................................................................... 45 5.3 Interlaboratory Comparison Program...................................................................... 46 6.0 ADMINISTRATIVE CONTROLS.................................................................................... 47 6.1 Responsibilities....................................................................................................... 47 6.2 Radioactive Effluent Reporting Requirements......................................................... 47 6.3 Change Mechanism................................................................................................ 52 6.4 Meteorological Data................................................................................................ 52 6.5 References.............................................................................................................. 53 7.0 BASIS............................................................................................................................ 55 7.1 Instrumentation....................................................................................................... 55 7.2 Radioactive Effluents............................................................................................... 55 7.3 Radiological Environmental Monitoring................................................................... 60 7.4 Abnormal Release or Abnormal Discharge Reporting............................................. 61

CH-ODCM-0001 Reference Use Page 3 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

List of Tables PART I Table 1.2 - Frequency Notation............................................................................................... 8 Table 1.3 - Radiological Effluent Controls Program Technical Specification Implementation.. 9 Table 3.1.1 - Radioactive Liquid Effluent Monitoring Instrumentation.................................... 11 Table 3.1.2 - Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements....................................................................................................... 12 Table 3.2.1 - Radioactive Gaseous Effluent Monitoring Instrumentation............................... 14 Table 3.2.2 - Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements.................................................................................. 16 Table 4.1 - Radioactive Liquid Effluent Sampling and Analysis............................................. 19 Table 4.2 - Radioactive Airborne Effluent Sampling and Analysis......................................... 24 Table 4.3 - Sampler Deposition/Transportation Correction Factors....................................... 26 Table 5.1 - Radiological Environmental Monitoring Program................................................. 32 Table 5.2 - Radiological Environmental Sampling Locations And Media............................... 35 Table 5.3 - Detection Capabilities for Environmental Sample Analysis Lower Limit of Detection (LLD)................................................................................................... 43 Table 5.4 - Reporting Levels for Radioactivity Concentrations in Environmental Samples...................................................................................... 44 List of Figures PART I Figure 1 - Environmental Radiological Sampling Points....................................................... 41 Figure 2 - 40CFR190 Sampling Points................................................................................. 42

CH-ODCM-0001 Reference Use Page 4 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table of Contents PART II 1.0 EFFLUENT MONITOR SETPOINTS............................................................................. 64 1.1 Liquid Effluents........................................................................................................ 64 1.2 Airborne Effluents.................................................................................................... 67 2.0 EFFLUENT CONCENTRATIONS................................................................................. 73 2.1 Liquid Effluent Concentrations................................................................................ 73 2.2 Airborne Effluent Concentrations............................................................................ 73 3.0 RADIOACTIVE EFFLUENT DOSE CALCULATIONS................................................... 75 3.1 Liquid Effluent Dose Calculations............................................................................ 75 3.2 Airborne Effluent Dose Calculations........................................................................ 79 4.0 LOWER LIMIT OF DETECTION (LLD)......................................................................... 91

CH-ODCM-0001 Reference Use Page 5 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

List of Tables PART II Table 1 - Deleted................................................................................................................... 67 Table 2 - Deleted................................................................................................................... 92 Table 3 - Bioaccumulation Factors........................................................................................ 92 Table 4 - Highest Potential Exposure Pathways for Estimating Dose.................................... 93 Table 5 - Stable Element Transfer Data................................................................................ 94 Table 6 - Recommended Values for Uap to Be Used for the Maximum Exposed Individual in Lieu of Site Specific Data................................................................... 95 Table 7 - Animal Consumption Rates.................................................................................... 95 Table 8 - External Dose Factors for Standing on Contaminated Ground............................... 96 Table 9 - Inhalation Dose Factors for Adult........................................................................... 99 Table 10 - Inhalation Dose Factors for Teenager................................................................ 102 Table 11 - Inhalation Dose Factors for Child....................................................................... 105 Table 12 - Inhalation Dose Factors for Infant...................................................................... 108 Table 13 - Ingestion Dose Factors for Adult........................................................................ 111 Table 14 - Ingestion Dose Factors for Teenager................................................................. 114 Table 15 - Ingestion Dose Factors for Child........................................................................ 117 Table 16 - Ingestion Dose Factors for Infant....................................................................... 120 Table 17 - Recommended Values for Other Parameters..................................................... 123 List of Figures PART II Figure 1 - Exclusion and Site Boundary Map........................................................................ 68 Figure 2 - Deleted..

Figure 3 - Deleted Figure 4 - Airborne Effluent Discharge Pathways.................................................................. 69 Figure 5 - Airborne Radioactive Waste Disposal System...................................................... 70

CH-ODCM-0001 Reference Use Page 6 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 1.0 PURPOSE AND SCOPE 1.1 Purpose 1.1.1 The purpose of the ODCM is to provide methodologies for and parameters necessary for calculating offsite doses, determination of gaseous and liquid radiation monitor set points, and administrative controls for effluent instrumentation, Radiological Effluent Tech Specs (RETS), and the Radiological Environmental Monitoring Program (REMP).

1.2 Scope 1.2.1 Radioactive effluents are generated from station activities. These controls provide methodologies ensuring these effluents are properly monitored and quantified to promote accurate dose reporting. Additional controls ensure station equipment and processes are used to minimize release to the environment. The combination of minimizing release, accurately reporting dose, and monitoring the facility environs provides the basis for ensuring that station activities are not negatively impacting public health and the environment.

2.0 DEFINITIONS 2.1 Abnormal Discharge - The unplanned or uncontrolled emission of an effluent (i.e.,

containing facility-related, licensed radioactive material) into the unrestricted area.

2.2 Abnormal Release - The unplanned or uncontrolled emission of an effluent (i.e.,

containing facility-related, licensed radioactive material).

2.3 Channel Check - A CHANNEL CHECK shall be the qualitative assessment of channel behavior during operation by observation. This determination shall include, where possible, comparison of the channel indication and/or status with other indications and/or status derived from independent instrument channels measuring the same parameter.

2.4 Channel Function Test - Injection of a simulated signal into the channel to verify that it is functional, including any alarm and/or trip initiating action.

2.5 Effluent Concentration Limit (ECL) - Radionuclide limits listed in 10 CFR Part 20, Appendix B, Table 2, Column 1.

2.6 Member(s) of the Public - Member(s) of the Public means any individual except when that individual is receiving occupational dose.

CH-ODCM-0001 Reference Use Page 7 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 2.7 Functional-Functionality - A system, subsystem, train, component or device shall be FUNCTIONAL or have FUNCTIONALITY when it is capable of performing its specified function(s) and when all necessary attendant instrumentation, controls, normal or emergency electrical power sources, cooling and seal water, lubrication, and other auxiliary equipment that are required for the system, subsystem, train, component, or device to perform its function(s) are also capable of performing their related support function(s).

2.8 Residual Radioactivity - Residual radioactivity means radioactivity in structures, materials, soils, ground water, and other media at a site resulting from activities under the licensee's control. This includes radioactivity from all licensed and unlicensed sources used by the licensee, but it excludes background radiation. It also includes radioactive materials remaining at the site as a result of routine or accidental releases of radioactive material at the site and previous burials at the site, even if those burials were made in accordance with the provisions of 10 CFR Part 20.

2.9 Restricted Area - An area to which access is limited by the licensee for the purpose of protecting individuals against undue risks from exposure to radiation and radioactive materials.

2.10 Site Boundary - The Site Boundary is the line beyond which the land is neither owned, or leased, nor controlled by the licensee.

2.11 Source Check - A SOURCE CHECK shall be the qualitative assessment of channel response when the channel sensor is exposed to a source of increased radioactivity.

2.12 Special Liquid - Non-routine release pathway in which normally non-radioactive liquid streams found to contain radioactive material, are non-routine, and will be treated on a case specific basis if and when this occurs.

2.13 Unrestricted Area - An UNRESTRICTED AREA shall be any area at or beyond the SITE BOUNDARY access to which is not controlled by the licensee for purposes of protection of individuals from exposure to radiation and radioactive materials, or any area within the SITE BOUNDARY used for residential quarters or for industrial, commercial, institutional, and/or recreational purposes.

2.14 Venting - VENTING shall be the controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration, or other operating condition, in such a manner that replacement air or gas is not provided or required during VENTING. Vent, used in system names, does not imply a VENTING process.

2.15 Water Effluent Concentration (WEC) - Radionuclide limits listed in 10 CFR Part 20, Appendix B, Table 2, Column 2.

CH-ODCM-0001 Reference Use Page 8 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 1.2 - Frequency Notation The surveillance intervals are defined as follows:

Notation Title FrequencyA S

Shift At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> D

Daily At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> W

Weekly At least once per 7 days BW Biweekly At least once per 14 days M

Monthly At least once per 31 days Q

Quarterly At least once per 92 days SA Semiannual At least once per 184 days A

Annually At least once per 366 days R

At least once per 18 months P

Prior to Prior to each release (Performance within 24 hrs.)

A. Each surveillance requirement shall be performed within the specified surveillance interval with a maximum allowable extension not to exceed 25 percent of the specified surveillance interval.

CH-ODCM-0001 Reference Use Page 9 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 1.3 - Radiological Effluent Controls Program Implementation NO-FC-10 Appendix E ODCM Implementing Step E.2.1.3.a 3.1.1, 3.2.1 E.2.1.3.b 4.1.1 E.2.1.3.c Table 4.1, Table 4.2 E.2.1.3.d 4.1.2 E.2.1.3.e 4.1.2B.1, 4.2.2B.1 E.2.1.3.f 4.1.3A, 4.2.4A E.2.1.3.g 4.2.2 E.2.1.3.h 4.2.3 E.2.1.3.i 4.3.1 E.3.1.3.a 5.1.1 E.3.1.3.b 5.2.1 E.3.1.3.c 5.3.1 E.1.2 6.3, 6.2.1D E.4.1 6.2.1 E.4.2 6.2.2

CH-ODCM-0001 Reference Use Page 10 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.0 INSTRUMENTATION 3.1 Radioactive Liquid Effluent Instrumentation 3.1.1 Limiting Condition for Operation A. The radioactive liquid effluent monitoring instrumentation channels shown in Table 3.1.1 shall be FUNCTIONAL with their alarm/trip setpoints set to ensure that the limits of Specification 3.1.1 are not exceeded. The alarm/trip setpoints of these channels shall be determined in accordance with Part II of the Off-Site Dose Calculation Manual.

APPLICABILITY: At all times ACTION:

1. With a radioactive liquid effluent monitoring instrumentation channel alarm/trip setpoint less conservative than required by the above specification, immediately suspend the releases of radioactive liquid effluents monitored by the affected channel or declare the channel non-functional.
2. With less than the minimum number of radioactive liquid effluent monitoring instrumentation channels functional, take the action shown in Table 3.1.1. Restore non-functional effluent monitoring instrumentation to FUNCTIONAL status within 30 days and, if unsuccessful, explain in the next Annual Radiological Effluent Release Report why this non-functionality was not corrected in a timely manner. The reporting requirement is limited to the following instrumentation that monitors effluent stream: RM-055.

3.1.2 Surveillance Requirements A. Each radioactive liquid effluent monitoring instrumentation channel shall be demonstrated FUNCTIONAL by performance of the CHANNEL CHECK, SOURCE CHECK, CALIBRATION, and CHANNEL FUNCTIONAL TEST at the frequencies shown in Table 3.1.2.

CH-ODCM-0001 Reference Use Page 11 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 3.1.1 - Radioactive Liquid Effluent Monitoring Instrumentation Instrument Minimum Channels Functional Action

1.

Radioactivity Monitor Providing Alarm and Automatic Termination of Release.

1.1 Liquid Radwaste Effluent Line (RM-055) 1 1, 4

2.

Flow Rate Measurement Device 2.1 Liquid Radwaste Effluent Line 1

2

3.

Radioactivity Recorder 3.1 Liquid Radwaste Effluent Line 1

3 Table Notation ACTION 1 With the number of channels FUNCTIONAL less than required by the Minimum Channels FUNCTIONAL requirement, effluent releases may continue provided that prior to initiating a release:

1. At least two independent samples are analyzed in accordance with applicable chemistry procedures.
2. At least two qualified individuals independently verify the release rate calculations.

ACTION 2 With the number of channels FUNCTIONAL less than required by the Minimum Channels FUNCTIONAL requirement, effluent releases may continue provided the flow rate is determined at least once per four hours during the actual release.

ACTION 3 With the number of channels FUNCTIONAL less than required by the Minimum Channels FUNCTIONAL requirement, effluent releases may continue provided the radioactivity is recorded manually at least once per four hours during the actual release.

ACTION 4 During the performance of source checks the effluent radiation monitor is unable to respond, hence is considered non-functional. Effluent releases may continue uninterrupted during the performance of source checks provided the operator is stationed at the monitor during the check. If the effluent radiation monitor fails the source check, carryout the action(s) of the Off-Site Dose Calculation Manual for the non-functional monitor or terminate the effluent release.

CH-ODCM-0001 Reference Use Page 12 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 3.1.2 - Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Instrument Channel Check Channel Source Check Calibration Function Test

1.

Radioactivity Monitor Providing Alarm and Automatic Isolation 1.1 RM-055 R

Q P

CH-ODCM-0001 Reference Use Page 13 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.2 Radioactive Gaseous Effluent Instrumentation 3.2.1 Limiting Condition for Operation A. The radioactive gaseous effluent monitoring instrumentation channels shown in Table 3.2.1 shall be FUNCTIONAL to ensure that the limits of Specification 3.2.1 are not exceeded.

APPLICABILITY: At all times ACTION:

1. With less than the minimum number of radioactive gaseous effluent monitoring instrumentation channels functional, take the action shown in Table 3.2.1. Restore non-functional effluent monitoring instrumentation to FUNCTIONAL status within 30 days and, if unsuccessful, explain in the next Annual Radiological Effluent Release Report why this non-functionality was not corrected in a timely manner. The reporting requirement is limited to the following instrumentation that monitors effluent streams: RM-043, RM-052 and Particulate Air Samplers.

3.2.2 Surveillance Requirements A. Each radioactive gaseous effluent monitoring instrumentation channel shall be demonstrated FUNCTIONAL by performance of the CHANNEL CHECK, CALIBRATION, and CHANNEL FUNCTIONAL TEST at the frequencies shown in Table 3.2.2.

CH-ODCM-0001 Reference Use Page 14 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 3.2.1 - Radioactive Gaseous Effluent Monitoring Instrumentation Instrument Minimum Channels Functional Action

1.

Forced Draft releases 1.1 Particulate-Auxiliary Bldg. Exhaust Stack (RM-052) 1 1,4 1.2 Particulate-Laboratory and Radwaste Processing Building Stack (RM-043) 1 2

1.3 Particulate air sampler-Portable filtered ventilation systems discharge 1

5

2.

Unventilated building opening 2.1 Particulate air sampler-open doorway/ open rollup door 1

6

3.

Open-air demolition 3.1 Particulate air samplers (4 air samplers at each open-air location) 4 7

4.

Flow Rate Measurement Devices 4.1 Auxiliary Building Exhaust Stack 1

3 4.2 Laboratory and Radwaste Processing Building Stack 1

3 4.3 Hand-held anemometer 1

3

CH-ODCM-0001 Reference Use Page 15 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 3.2.1 Radioactive Gaseous Effluent Monitoring Instrumentation Table Notation ACTION 1 If the Auxiliary Building Exhaust Stack Particulate Sampler is non-functional, ventilation of the Auxiliary Building may continue through the Auxiliary Building Exhaust Stack provided sample collection in accordance with Table 4.2 using auxiliary sample collection equipment is initiated within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the declaration of non-functionality by the ISFSI Shift Supervisor (ISS).

ACTION 2 If the Particulate Sampler is non-functional, ventilation of the LRWPB may continue via the LRWPB Stack provided sample collection using auxiliary sample collection equipment is initiated within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the declaration of non-functionality, by the ISFSI Shift Supervisor (ISS), in accordance with Table 4.2.

ACTION 3 With the number of channels FUNCTIONAL less than required by the Minimum Channels FUNCTIONAL requirement, effluent releases may continue provided the flowrate is estimated or recorded manually at least once per four hours during the actual release.

ACTION 4 During the ventilation of airborne effluents from the Auxiliary Building Exhaust Stack at least one Auxiliary Building Exhaust fan shall be in operation.

ACTION 5 If portable air sampler monitoring the discharged of a portable filtered ventilation unit OR its associated flowmeter is non-functional, active decommissioning may continue provided the portable air sampler is replaced within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of declaration of non-functionality. If air sampler is unable to be replaced within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, secure the release fan AND cease active decommissioning in the area monitored by the non-functioning air sampler.

ACTION 6 If portable air sampler monitoring open doorways in unventilated building flowpaths OR its associated flowmeter is non-functional, active decommissioning may continue provided the portable air sampler is replaced within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of declaration of non-functionality. If air sampler is unable to be replaced within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, close the door associated with this air sampler OR cease active decommissioning work until the air sampler can be replaced.

ACTION 7 If any of the 4 air samplers monitoring air around an open-air demolition location OR their associated flowmeters are non-functional, active decommissioning may continue provided the portable air sampler is replaced within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of declaration of non-functionality. If the open-air demolition location is unable to be monitored by 4 air samplers, cease active open-air decommissioning at the affected location.

CH-ODCM-0001 Reference Use Page 16 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 3.2.2 - Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Instrument Channel Check Calibration Channel Function Test Source Check

1.

Flowrate Monitors 1.1 RM-043 Sampler D

R Q

1.2 RM-052 Sampler D

R Q

1.3 Auxiliary Bldg Exhaust Stack D

R Q

1.4 Laboratory and Radwaste Process Bldg Exhaust Stack D

R Q

Operations Check Air Flow Calibration

2.

Environmental Monitors 2.1 RM-023 - Sample Station #40 M

A 2.2 RM-024 - Sample Station #41 M

A 2.3 RM-025 - Sample Station #28 2.4 RM-026 - Sample Station #36 2.5 RM-027 - Sample Station #37 M

A 2.6 RM-028 - Sample Station #38 2.7 RM-029 - Sample Station #39 2.8 RM-035 - Sample Station #1 2.9 RM-036 - Sample Station #2 M

A 2.10 RM-037 - Sample Station #3 2.11 RM-038 - Sample Station #4 M

A 2.12 RM-039 - Sample Station #5 2.13 RM-040 - Sample Station #32 M

A

3.

Decommissioning portable air sampler flowmeters 3.1 All sample stations W1 A

1-Operation check performed only when the unit is started to support active decommissioning.

CH-ODCM-0001 Reference Use Page 17 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 4.0 RADIOACTIVE EFFLUENTS 4.1 Radioactive Liquid Effluents 4.1.1 Concentration A. Limiting Condition for Operation

1. The release rate of radioactive material in liquid effluents shall be controlled such that the instantaneous concentrations for radionuclides do not exceed the values specified in 10 CFR Part 20 for liquid effluents at site discharge. To support facility operations, RP/Chemistry supervision may increase this limit up to the limit specified in QATR Appendix E, E.2.1.3.b.
2. QATR Appendix E, E.2.1.3.b establishes the administrative control limit on concentration of radioactive material, other than dissolved or entrained noble gases, released in liquid effluents to unrestricted areas conforming to ten times 10 CFR Part 20.1001-20.2401, Appendix B, Table 2, Column 2.

APPLICABILITY: At all times ACTION:

a.

When the concentration of radioactive material released at site discharge exceeds the above limits, appropriate corrective actions shall be taken immediately to restore concentrations within the above limits.

CH-ODCM-0001 Reference Use Page 18 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

B. Surveillance Requirements i

NOTE i

Radioactive liquid waste includes water used for fire suppression in areas of the facility that may contain radioactivity. These liquids are required to be monitored prior to release.

1. Radioactive liquid waste shall be sampled and analyzed according to the sampling and analysis program in Table 4.1.
2. The results of the radioactivity analysis shall be used with the calculational methods in Part II of the Off-Site Dose Calculation Manual.
3. To assure that the concentration at the point of release is maintained within the limits of QATR Appendix E, E.2.1.3.b.
4. Records shall be maintained of the radioactive concentrations and volume before dilution of each batch of liquid effluent released and of the average dilution flow and length of time over which each discharge occurred. Analytical results shall be submitted to the Commission in accordance with Part I, Section 6.0 of the Off-Site Dose Calculation Manual.

CH-ODCM-0001 Reference Use Page 19 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 4.1 - Radioactive Liquid Effluent Sampling and Analysis A.

Liquid Releases Sampling Frequency Type of Activity Analysis Lower Limit of Detection (LLD) (Ci/ml) A Each Batch Principal Gamma Emitters B 5.0E-07 Monthly Composite C H-3 1.0E-05 Monthly Composite C Gross Alpha 1.0E-07 Quarterly Composite C Sr-89, Sr-90 5.0E-08 Quarterly Composite C Fe-55, Ni-63 1.0E-06 NOTES:

A. LLD is defined in Part II of the Off-Site Dose Calculation Manual.

B. The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, and Ce-141 for fission and corrosion products. Ce-144 shall also be measured, but with a LLD of 5.0E-06.

C. To be representative of the average quantities and concentrations of radioactive materials in liquid effluents, samples should be collected in proportion to the rate of flow of the effluent stream. Prior to analyses, all samples taken for the composite should be mixed in order for the composite sample to be representative of the average effluent release.

CH-ODCM-0001 Reference Use Page 20 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 4.1.2 Dose from Radioactive Liquid Effluents A. Limiting Condition for Operation

1. The dose or dose commitment to an individual in unrestricted areas from radioactive materials in liquid effluents shall be limited to the following:
a.

During any calendar quarter: Less than or equal to 1.5 mrem to the total body and 5 mrem to any organ; and

b.

During any calendar year: Less than or equal to 3 mrem to the total body and 10 mrem to any organ.

APPLICABILITY: At all times ACTION:

a.

If the dose contribution, due to the cumulative release of radioactive materials in liquid effluents, exceeds the annual or quarterly dose objectives, submit a Special Report to the NRC, per Section 6.2.4, within 30 days.

B. Surveillance Requirements

1. Cumulative dose contributions from liquid effluents for the current calendar quarter and the current calendar year shall be determined in accordance with the methodology and parameters in Part II of the Off-Site Dose Calculation Manual at least once per quarter.

CH-ODCM-0001 Reference Use Page 21 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 4.1.3 Liquid Radwaste Treatment A. Limiting Condition for Operation

1. The Liquid Radwaste Treatment System shall be FUNCTIONAL, and appropriate portions of these systems shall be used to reduce releases of radioactivity when the projected doses due to the liquid effluent, from each unit, to UNRESTRICTED AREAS would exceed 0.06 mrem to the whole body or 0.2 mrem to any organ in a 31-day period.

APPLICABILITY: At all times ACTION:

a.

With radioactive liquid waste being discharged without treatment and in excess of the above limits and any portion of the Liquid Radwaste Treatment System not in operation, prepare and submit to the Nuclear Regulatory Commission within 30 days, pursuant to 10 CFR 50, Appendix I, a Special Report that includes the following information:

1)

Explanation of why liquid radwaste was being discharged without treatment, identification of equipment or subsystem(s) not functional and reasons for non-functionality.

2)

Action(s) taken to restore the non-functional equipment to functional status.

3)

Summary description of action(s) taken to prevent a recurrence.

B. Surveillance Requirements

1. Dose due to liquid releases shall be projected frequently and at least once per quarter, in accordance with the methodology and parameters in Part II of the Off-Site Dose Calculation Manual, when Liquid Radwaste Treatment Systems are not fully FUNCTIONAL.
2. FUNCTIONAL is defined as follows:

CH-ODCM-0001 Reference Use Page 22 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

a.

A filtration/ion exchange (FIX) system will be utilized for processing liquid radwaste. The system consists of a booster pump, charcoal pretreatment filter, and pressure vessels containing organic/inorganic resins, which can be configured for optimum performance. The effluent from the FIX system is directed to storage tanks for release.

4.1.3B.2 (continued)

b.

Waste filters (WD-17A and WD-17B) are used only on those occasions when considered necessary, otherwise the flows from the low activity fluids may bypass the filters. No credit for decontamination factors (iodines, Cs, Rb, others) was taken for these filters during the 10 CFR Part 50 Appendix I dose design objective evaluation; therefore, the non-functionality of these filters does not affect the dose contributions to any individual in the unrestricted areas via liquid pathways. The non-functionality of waste filters will not be considered a reportable event in accordance with the Action listed above.

4.1.4 Liquid Holdup Tanks Tanks included in this Specification are those outdoor tanks that are not surrounded by liners, dikes, or walls capable of holding the tanks contents and that do not have tank overflows and surrounding area drains connected to the liquid radwaste treatment system.

A. Limiting Condition for Operation

1. The quantity of radioactive material contained in each unprotected outdoor liquid holdup tank shall not exceed 10 curies, excluding tritium and dissolved or entrained noble gases.

APPLICABILITY: At all times ACTION:

a.

When the quantity of radioactive material in any unprotected outdoor liquid holdup tank exceeds 10 curies, excluding tritium and dissolved or entrained noble gasses, immediately suspend all additions of radioactive material to the tank and within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> reduce the tank contents to within the limit.

B. Surveillance Requirements

CH-ODCM-0001 Reference Use Page 23 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

1. The quantity of radioactive material contained in each outdoor liquid holdup tank shall be determined to be within the above limit by analyzing a representative sample of the tanks contents at least once per 7 days when radioactive material is being added to the tank.

4.2 Radioactive Gaseous Effluents 4.2.1 Concentration A. Limiting Condition for Operation

1. The release rate of radioactive material in airborne effluents shall be controlled such that the instantaneous concentrations of radionuclides does not exceed the values specified in 10 CFR Part 20 for airborne effluents at the unrestricted area boundary.

APPLICABILITY: At all times ACTION:

a.

When the concentration of radioactive material released to unrestricted areas exceeds the above limits, appropriate corrective actions shall be taken immediately to restore concentrations within the above limits.

B. Surveillance Requirements i

NOTE i

Radioactive gaseous wastes include atmospheres in areas where gaseous fire suppression systems are utilized or where smoke is produced as a result of fire in areas of the facility that may contain radioactivity. These atmospheres are required to be monitored prior to gaseous release to unrestricted areas.

1. Radioactive gaseous wastes shall be sampled and analyzed according to the sampling and analysis program of Table 4.2. The results of the radioactivity analysis shall be used to assure the limits in Step 4.2.1A are not exceeded.

CH-ODCM-0001 Reference Use Page 24 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 4.2 - Radioactive Airborne Effluent Sampling and Analysis A.

Auxiliary Building Exhaust Stack D Sampling Frequency Type of Activity Analysis Lower Limit of Detection (LLD) (Ci/ml) A Weekly (Particulate Sample)

Principal Gamma Emitters B 1.0E-11 Weekly Tritium (H-3) 1.0E-06 Monthly Composite C Gross Alpha 1.0E-11 Quarterly Composite (Particulate Samples)

Sr-89, Sr-90 1.0E-11 B.

Laboratory and Radwaste Building Exhaust Stack D Sampling Frequency Type of Activity Analysis Lower Limit of Detection (LLD) (Ci/ml) A Weekly (Particulate Sample)

Principal Gamma Emitters B 1.0E-11 Monthly Composite C Gross Alpha 1.0E-11 Quarterly Composite (Particulate Sample)

Sr-89, Sr-90 1.0E-11 C.

Forced Draft Exhaust discharge Sampling Frequency Type of Activity Analysis Lower Limit of Detection (LLD) (Ci/ml) A Weekly (Particulate Sample)

Principal Gamma Emitters B 1.0E-11 Monthly Composite C Gross Alpha 1.0E-11 Quarterly Composite (Particulate Sample)

Sr-90 1.0E-11 D.

Unventilated building doorways Sampling Frequency Type of Activity Analysis Lower Limit of Detection (LLD) (Ci/ml) A Weekly (Particulate Sample)

Principal Gamma Emitters B 1.0E-11 Monthly Composite C Gross Alpha 1.0E-11 Quarterly Composite (Particulate Sample)

Sr-90 1.0E-11

CH-ODCM-0001 Reference Use Page 25 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

E.

Open-Air Demolition locations Sampling Frequency Type of Activity Analysis Lower Limit of Detection (LLD) (Ci/ml) A Weekly (Particulate Sample)

Principal Gamma Emitters B 1.0E-11 Monthly Composite C Gross Alpha 1.0E-11 Quarterly Composite (Particulate Sample)

Sr-90 1.0E-11 NOTES:

A. LLD is defined in Part II of the Off-Site Dose Calculation Manual.

B. The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, and Ce-144 for particulate releases.

C. Frequency requirement may be satisfied using weekly gross alpha results from particulate sampling media.

D. Particulate samples shall be corrected for sampler deposition/transportation efficiency by using the approved software programs or by multiplying the activity obtained by the associated sampler multiplication factor (See Table 4.3).

CH-ODCM-0001 Reference Use Page 26 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 4.3 - Sampler Deposition/Transportation Correction Factors Sampler Sample Particulate DF ACTMULT RM-052 AB 0.638 1.567 RM-043 LRWPB 0.809 1.236 Portable Air Sampler Forced Draft, Unventilated Building, Open-Air 1.00 1.00 ACRONYM DEFINITIONS:

AB - Auxiliary Building Exhaust Stack LRWPB - Laboratory and Rad Waste Processing Building DF - Deposition Factor ACTMULT - Activity multiplication factor to correct for sample loss.

CH-ODCM-0001 Reference Use Page 27 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 4.2.2 Dose - H-3 and Radioactive Material in Particulate Form with Half-Lives Greater than 8 Days (Other than Noble Gases)

A. Limiting Condition for Operation

1. The dose to an individual or dose commitment to any organ of an individual in unrestricted areas due to the release of H-3 and radioactive materials in particulate form with half-lives greater than eight days (excluding noble gases) in airborne effluents shall be limited to the following:
a.

During any calendar quarter: Less than or equal to 7.5 mrem to any organ; and

b.

During any calendar year: Less than or equal to 15 mrem to any organ.

APPLICABILITY: At all times ACTION:

a.

If the dose contribution, due to the cumulative release of H-3 and radioactive materials in particulate form with half-lives greater than eight days, exceeds the annual or quarterly dose objectives, submit a Special Report to the NRC per Section 6.2.4, within 30 days.

B. Surveillance Requirements

1. The radiation dose contributions from H-3 and radioactive materials in particulate form with half-lives greater than eight days (excluding noble gases) in airborne effluents shall be determined, in accordance with the methodologies and parameters of Part II of the Off-Site Dose Calculation Manual, on a quarterly basis.

4.2.3 Gaseous Radwaste Treatment A. Limiting Condition for Operation

1. In accordance with QATR Appendix E, E.2.1.3.f, the Ventilation Exhaust Systems shall be FUNCTIONAL, and appropriate portions of these systems shall be used to reduce the releases of radioactivity when the projected doses in 31 days due to gaseous effluent releases to areas at and beyond the SITE BOUNDARY would exceed:

CH-ODCM-0001 Reference Use Page 28 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

a.

0.2 mrad to air from gamma radiation, or

b.

0.4 mrad to air from beta radiation, or

c.

0.3 mrem to any organ of a MEMBER OF THE PUBLIC APPLICABILITY: At all times ACTION:

a.

With radioactive gaseous waste being discharged without treatment and in excess of the above limits, prepare and submit a report to the Nuclear Regulatory Commission within 30 days, pursuant to 10 CFR 50, Appendix I, a special report that includes the following information:

1)

Identification of equipment or subsystem(s) not functional and reasons for non-functionality.

2)

Action(s) taken to restore the non-functional equipment to functional status.

3)

Summary description of action(s) taken to prevent a recurrence.

B. Surveillance Requirements

1. Dose due to gaseous releases shall be projected frequently and at least once per quarter, in accordance with the methodology and parameters in Part II of the Off-Site Dose Calculation Manual, when Ventilation Exhaust Systems are not fully FUNCTIONAL.
2. FUNCTIONAL is defined as follows:
a.

Ventilation Exhaust Systems

1)

The radioactive effluents from the controlled access area of the auxiliary building are filtered by the HEPA filters in the auxiliary building ventilation system. If the radioactive effluents are discharged without the HEPA filters and it is confirmed that one half of the annual dose objective will be exceeded during the calendar quarter, a special report shall be submitted to the Commission pursuant to Section 4.2.3A.

CH-ODCM-0001 Reference Use Page 29 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 4.3 Uranium Fuel Cycle 4.3.1 Total Dose-Uranium Fuel Cycle A. Limiting Condition for Operation

1. The dose to any real individual from uranium fuel cycle sources shall be limited to 25 mrem to the total body or any organ (except the thyroid, which shall be limited to 75 mrem) during each calendar year.

APPLICABILITY: At all times ACTION:

a.

With the calculated dose from the release of radioactive materials in liquid or gaseous effluents exceeding twice the limits of specifications 4.1.2A, or 4.2.2A, calculations shall be made including direct radiation contribution from the facility and outside storage tanks to determine whether the above limits have been exceeded. If such is the case, in lieu of any other report required by Section 6.2, prepare and submit a Special Report to the Commission pursuant to QATR Appendix E, E.2.1 that defines the corrective action to be taken to reduce subsequent releases to prevent recurrence of exceeding the above limits and includes the schedule for achieving conformance with the above limits. This Special Report, as defined in 10 CFR Part 20.2203(a)(4) and 20.2203(b), shall include an analysis that estimates the radiation exposure (dose) to a MEMBER OF THE PUBLIC from uranium fuel cycle sources, including all effluent pathways and direct radiation, for the calendar year that includes the release(s) covered by this report. It shall also describe levels of radiation and concentration of radioactive material involved, and the cause of exposure levels or concentrations. If the estimated dose(s) exceeds the above limits, and if the release condition resulting in the violation of 40 CFR Part 190 or 10 CFR Part 72.104 has not already been corrected, the Special Report shall include a request for a variance in accordance with the provisions of 40 CFR Part 190 or 10 CFR Part 72.104. Submittal of the report is considered a timely request, and a variance is granted until staff action on the request is complete.

CH-ODCM-0001 Reference Use Page 30 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 4.3.1 (continued)

B. Surveillance Requirements

1. Cumulative dose contributions from liquid and gaseous effluents shall be determined in accordance with surveillance requirements 4.1.2B and 4.2.2B and in accordance with the methodology and parameters in Part II of the Off-Site Dose Calculation Manual.

5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP) 5.1 Monitoring Program 5.1.1 Limiting Condition for Operation A. The Radiological Environmental Monitoring Program shall be conducted as specified in Table 5.1.

APPLICABILITY: At all times ACTION:

1. Analytical results of this program and deviations from the sampling schedule shall be reported to the Nuclear Regulatory Commission in the Annual Radiological Environmental Operating Report (Section 6.2).
2. If the level of radioactivity from calculated doses leads to a higher exposure pathway to individuals, this pathway shall be added to the Radiological Environmental Monitoring Program. Modifications to the program shall be reported in the Annual Radiological Environmental Operating Report to the Nuclear Regulatory Commission.
3. If the level of radioactivity in an environmental sampling medium exceeds the reporting level specified in Table 5.4, and the activity is attributable to facility operation, a Special Report shall be prepared and submitted to the Nuclear Regulatory Commission within 30 days (Section 6.2.4). The detection capabilities of the equipment used for the analysis of environmental samples must meet the requirements of Table 5.3 for Lower Level of Detection (LLD).

CH-ODCM-0001 Reference Use Page 31 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 5.1.1A (continued)

4. If the level of radioactivity in a sample from either an onsite or offsite well, performed per the Site Groundwater Protection Program, exceeds the reporting level specified in Table 5.4, and the activity is attributable to facility operation, a Special Report shall be prepared and submitted to the Nuclear Regulatory Commission within 30 days (Section 6.2.4). The detection capabilities of the equipment used for the analysis of environmental samples must meet the requirements of Table 5.3 for Lower Level of Detection (LLD). Copies of the Special Report will be forwarded to State/Local authorities.

[AR 39127]

5. If the level of radioactivity from either an onsite or offsite well, performed per the Site Groundwater Protection Program exceeds the reporting level specified in Table 5.4, and the activity is attributable to facility operations, state and local authorities shall be notified by the end of the next business day. NRC shall be notified per FCSI-RA-105, Reporting of Events and Conditions. [AR 39127]
6. Radiological environmental sampling locations and the media that is utilized for analysis are presented in Table 5.2. Sampling locations are also illustrated on the map, Figure 1. Details of the quarterly emergency TLD locations are contained in test CH-FT-RV-0003, Environmental Sample Collection - Quarterly/Environmental Dosimeters (TLDs). Each TLD sample location contains one dosimeter that is exchanged quarterly for REMP sampling and as needed for Emergency Planning Zone monitoring.
7. Deviations from the monitoring program, presented in this section and detailed in Table 5.2, are permitted if specimens are unobtainable due to mitigating circumstances such as hazardous conditions, seasonal unavailability, malfunction of equipment, or if a person discontinues participation in the program, etc. If the equipment malfunctions, corrective actions will be completed as soon as practicable. If a person no longer supplies samples, a replacement will be made if possible. All deviations from the sampling schedule will be described in the Annual Radiological Environmental Operating Report, pursuant to Section 6.2.

5.1.2 Surveillance Requirements A. The Radiological Environmental Monitoring Program (REMP) samples shall be collected and analyzed in accordance with Tables 5.1, 5.2, and 5.3.

CH-ODCM-0001 Reference Use Page 32 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.1 - Radiological Environmental Monitoring Program Exposure Pathway and/or Sample Collection Site A Type of Analysis B Frequency

1. Direct Radiation A. 14 TLD indicator stations.

B. An inner-ring of 16 stations, one in each cardinal sector in the general area of the unrestricted area boundary and within 2.5 miles.

C. An outer-ring of 16 background stations, one in each cardinal sector located outside of the inner-ring, but not closer than approximately 2.5 miles and one additional remote background station for a total of 17.F D. Other TLDs may be placed at special interest locations beyond the Restricted Area where either a MEMBER OF THE PUBLIC or Omaha Public Power District employees have routine access.

Gamma dose Gamma dose Gamma dose Gamma dose Quarterly Quarterly Quarterly Quarterly

2. Air Monitoring A. Indicator Stations
1. Three stations in the general area of the unrestricted area boundary
2. City of Blair
3. Desoto Township B. One background station F Filter for Gross Beta C Filter for Gamma Isotopic Weekly Quarterly composite of weekly filters
3. Water A. Missouri River at nearest downstream drinking water intake.

B. Missouri River downstream near the mixing zone.

C. Missouri River upstream of Facility intake (background)F.

Gamma Isotopic, H-3 Monthly for Gamma isotopic analysis.

Quarterly composite for H-3 Analysis

4. Milk D A. Nearest milk animal (cow or goat) within 5 miles B. Milk animal (cow or goat) between 5 miles and 18.75 miles (background)F.

Gamma Isotopic Monthly

CH-ODCM-0001 Reference Use Page 33 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.1 - Radiological Environmental Monitoring Program Exposure Pathway and/or Sample Collection Site A Type of Analysis B Frequency

5. Fish A. Four fish samples within vicinity of Facility discharge.

B. One background sample upstream of Facility discharge.

Gamma Isotopic Once per season (May to October)

6. Vegetables or Food Products E A. One sample in the highest exposure pathway.

B. One sample from onsite crop field C. One sample outside of 5 miles (background)F.

Gamma Isotopic Once per season (May to October)

7. Groundwater A. Three samples from sources potentially affected by facility operations.

B. One sample outside of 5 miles (background)F.

H3, Gross Beta, Gamma Isotopic, Sr-90 Quarterly

8. Vegetation in lieu of milk A. One sample at the highest annual average D/Q offsite location.

B. One sample at the second highest annual average D/Q offsite location.

C. One sample outside of 5 miles (background) F.

Gamma Isotopic Monthly (when available)

CH-ODCM-0001 Reference Use Page 34 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

NOTES:

A. See Table 5.3 for required detection limits.

B. The Lower Limit of Detection (LLD) for analysis is defined in the Off-Site Dose Calculation Manual in accordance with the wording of NUREG-1301.

C. When a gross beta count indicates radioactivity greater than 2.5E-13 Ci/ml or 0.25 pCi/m3, (ten times the yearly mean), a gamma spectral analysis will be performed.

D. If milk samples are temporarily not available at a sampling site due to mitigating circumstances, then vegetation (broadleaf, pasture grass, etc.) shall be collected as an alternate sample at the site. If there are no milk producers within the entire 5-mile radius of the facility, then vegetation shall be collected monthly, when available, at two offsite locations having the highest calculated annual average ground level D/Q and a background locale. (Reference Off-Site Dose Calculation Manual, Part II, Table 4 "Highest Potential Exposure Pathways for Estimating Dose")

E. Samples should be collected from garden plots of 500 ft2 or more.

F. This sample may not be located in the least prevalent wind direction. The Branch Technical Position paper, Table 1, subnote "d" says this regarding background information, or control locations. "The purpose of this sample is to obtain background information. If it is not practical to establish control locations in accordance with the distance and wind direction criteria, other sites which provide valid background data may be substituted".

CH-ODCM-0001 Reference Use Page 35 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.2 - Radiological Environmental Sampling Locations And Media Sample Station No.

Approximate Collection Sites Approximate Distance from Center of Containment (miles)

Approximate Direction (degrees from true north)

Sector Air Monitoring TLD Water Milk Sedi-ment Fish Vegetables and Food Products Ground-water Airborne Particulate 1

Onsite Station, 110-meter weather tower 0.53 293°/WNW P

X 2C,E Onsite Station, adjacent to old plant access road 0.59 207°/SSW K

X X

3 Offsite Station, Intersection of Hwy. 75 and farm access road 0.94 145°/SE G

X 4

Blair OPPD office 2.86 305°/NW Q

X X

5A 6

Fort Calhoun, NE City Hall 5.18 150°/SSE H

X 7

Fence around intake gate, Desoto Wildlife Refuge 2.07 102°/ESE F

X 8

Onsite Station, entrance to Plant Site from Hwy. 75 0.55 191°/S J

X 9

Onsite Station, NW of Plant 0.68 305°/NW Q

X 10 Onsite Station, WSW of Plant 0.61 242°/WSW M

X 11 Offsite Station, SE of Plant 1.07 39°/SE G

X

CH-ODCM-0001 Reference Use Page 36 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.2 - Radiological Environmental Sampling Locations And Media Sample Station No.

Approximate Collection Sites Approximate Distance from Center of Containment (miles)

Approximate Direction (degrees from true north)

Sector Air Monitoring TLD Water Milk Sedi-ment Fish Vegetables and Food Products Ground-water Airborne Particulate 12 Metropolitan Utilities Dist., Florence Treatment Plant North Omaha, NE 14.3 154°/SSE H

X 13 West bank Missouri River, downstream from Plant discharge 0.45 108°/ESE F

X X

14D Upstream from Intake Bldg, west bank of river 0.09 4°/N A

X X

15 Smith Farm 1.99 134°/SE G

X 16A 17A 18A 19A 20B,D,F Mohr Dairy 9.86 186°/S J

X X

X 21A 22 Fish Sampling Area, Missouri River 0.08 (R.M. 645.0) 6°/N A

X 23D Fish Sampling Area, Missouri River 17.9 (R.M. 666.0) 358°/N A

X 24A 25A 26A 27A

CH-ODCM-0001 Reference Use Page 37 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.2 - Radiological Environmental Sampling Locations And Media Sample Station No.

Approximate Collection Sites Approximate Distance from Center of Containment (miles)

Approximate Direction (degrees from true north)

Sector Air Monitoring TLD Water Milk Sedi-ment Fish Vegetables and Food Products Ground-water Airborne Particulate 28 Alvin Pechnik Farm 0.94 163 H

X 29A 30A 31A 32D Valley Substation #902 19.6 221°/SW L

X X

33A 34A 35 Onsite Farm Field 0.52 118°/ESE F

X 36 Offsite Station Intersection Hwy 75/Co.

Rd. P37 0.75 227°/SW L

X 37 Offsite Station Desoto Township 1.57 144°/SE G

X X

38A 39A 40A 41B,C Dowler Acreage 0.73 175°/S J

X X

42 Sector A-1 1.94 0°/NORTH A

X 43 Sector B-1 1.97 16°/NNE B

X 44 Sector C-1 1.56 41°/NE C

X 45 Sector D-1 1.34 71°/ENE D

X 46 Sector E-1 1.54 90°/EAST E

X 47 Sector F-1 0.45 108°/ESE F

X

CH-ODCM-0001 Reference Use Page 38 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.2 - Radiological Environmental Sampling Locations And Media Sample Station No.

Approximate Collection Sites Approximate Distance from Center of Containment (miles)

Approximate Direction (degrees from true north)

Sector Air Monitoring TLD Water Milk Sedi-ment Fish Vegetables and Food Products Ground-water Airborne Particulate 48 Sector G-1 1.99 134°/SE G

X 49 Sector H-1 1.04 159°/SSE H

X 50 Sector J-1 0.71 179°/SOUTH J

X 51 Sector K-1 0.61 205°/SSW K

X 52 Sector L-1 0.74 229°/SW L

X 53 Sector M-1 0.93 248°/WSW M

X 54 Sector N-1 1.31 266°/WEST N

X 55 Sector P-1 0.60 291°/WNW P

X 56 Sector Q-1 0.67 307°/NW Q

X 57 Sector R-1 2.32 328°/NNW R

X 58D Sector A-2 4.54 350°/NORTH A

X 59D Sector B-2 2.95 26°/NNE B

X 60D Sector C-2 3.32 50°/NE C

X 61D Sector D-2 3.11 75°/ENE D

X 62D Sector E-2 2.51 90°/EAST E

X 63D Sector F-2 2.91 110°/ESE F

X 64D Sector G-2 3.00 140°/SE G

X 65D Sector H-2 2.58 154°/SSE H

X 66D Sector J-2 3.53 181°/SOUTH J

X 67D Sector K-2 2.52 205°/SSW K

X 68D Sector L-2 2.77 214°/SW L

X 69D Sector M-2 2.86 243°/WSW M

X

CH-ODCM-0001 Reference Use Page 39 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.2 - Radiological Environmental Sampling Locations And Media Sample Station No.

Approximate Collection Sites Approximate Distance from Center of Containment (miles)

Approximate Direction (degrees from true north)

Sector Air Monitoring TLD Water Milk Sedi-ment Fish Vegetables and Food Products Ground-water Airborne Particulate 70D Sector N-2 2.54 263°/WEST N

X 71D Sector P-2 2.99 299°/WNW P

X 72D Sector Q-2 3.37 311°/NW Q

X 73D Sector R-2 3.81 328°/NNW R

X 74 D. Miller Farm 0.65 203°/SSW K

X 75B,C Lomp Acreage 0.65 163°/SSE H

X X

X 76A 77G River N-1 0.17 328°/NNW R

X 78G River S-1 0.14 85°/EAST E

X 79G Lagoon S-1 0.24 131°/SE G

X 80G Parking S-1 0.27 158°/SSE H

X 81G Training W-1 0.28 194°/SSW K

X 82G Switchyard S-1 0.21 219°/SW L

X 83G Switchyard SE-1 0.14 231°/SW L

X 84G Switchyard NE-1 0.18 256°/WSW M

X 85G Switchyard W-1 0.29 233°/WEST L

X 86G Switchyard N-1 0.24 262°/WEST N

X 87G Range S-1 0.20 286°/WNW P

X 88G Mausoleum E-1 0.37 216°/SW L

X 89 C, Miller 3.30 210°/SSW K

X

CH-ODCM-0001 Reference Use Page 40 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

NOTES:

A.

Location is either not in use or currently discontinued and is documented in the table for reference only.

B.

If milk samples are temporarily not available at a sampling site due to mitigating circumstances, then vegetation (broadleaf, pasture grass, etc.) shall be collected as an alternate sample at the site. If there are no milk producers within the entire 5-mile radius of the facility, then vegetation shall be collected monthly, when available, at two offsite locations having the highest calculated annual average ground level D/Q and a background locale. (Reference Off-Site Dose Calculation Manual, Part II, Table 4 "Highest Potential Exposure Pathways for Estimating Dose")

C.

Locations represent highest potential exposure pathways as determined by the biennial Land Use Survey, performed in accordance with Part I, Section 7.3.2, of the Off-Site Dose Calculation Manual and are monitored as such.

D.

Background location (control). All other locations are indicators.

E.

Location for monitoring Sector K High Exposure Pathway Resident Receptor for inhalation.

F.

When broad leaf (pasture grasses) are being collected in lieu of milk, background broad leaf samples will be collected at a background locale.

G.

Location for special interest monitoring general dose to the public per 40CFR190 (Figure 2)

CH-ODCM-0001 Reference Use Page 41 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Figure 1 - Environmental Radiological Sampling Points

(*)

Locations currently discontinued are not illustrated.

CH-ODCM-0001 Reference Use Page 42 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Figure 2-40CFR190 Sampling Points

CH-ODCM-0001 Reference Use Page 43 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.3 - Detection Capabilities for Environmental Sample Analysis Lower Limit of Detection (LLD) A, B, C Sample Units Gross Beta H-3 Mn-54 Fe-59 Co-58, Co-60 Zn-65 Zr-95 Nb-95 Cs-134 Cs-137 Ba-140 La-140 Water pCi/L 4

2.0E+03 1.5E+01 3.0E+01 1.5E+01 3.0E+01 1.5E+01 1.5E+01 1.5E+01 1.8E+01 1.5E+01 Fish pCi/kg (wet) 1.3E+02 2.6E+02 1.3E+02 2.6E+02 1.3E+02 1.5E+02 Milk pCi/L 1.5E+01 1.8E+01 1.5E+01 Airborne Particulates pCi/m3 1.0E-02 1.0E-02 1.0E-02 Sediment pCi/kg (dry) 1.5E+02 1.8E+02 Grass or Broad Leaf Vegetation/

Vegetables or Food Products pCi/kg (wet) 6.0E+01 8.0E+01 A. This list does not mean that only these nuclides are to be considered. Other peaks that are identifiable as Facility effluents, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating Report pursuant to Part I, Section 6.2, of the Off-Site Dose Calculation Manual.

B. Required detection capabilities for thermoluminescent dosimeters used for environmental measurements shall be in accordance with the recommendations of Regulatory Guide 4.13.

C. The LLD is defined in Part II of the Off-Site Dose Calculation Manual.

CH-ODCM-0001 Reference Use Page 44 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5.4 - Reporting Levels for Radioactivity Concentrations in Environmental Samples A Sample Units H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-95 Nb-95 Cs-134 Cs-137 Ba-140 La-140 Water pCi/L 2.0E+04 1.0E+03 4.0E+02 1.0E+03 3.0E+02 3.0E+02 4.0E+02 4.0E+02 3.0E+01 5.0E+01 2.0E+02 Fish pCi/kg (wet) 3.0E+04 1.0E+04 3.0E+04 1.0E+04 2.0E+04 1.0E+03 2.0E+03 Milk pCi/L 6.0E+01 7.0E+01 3.0E+02 Airborne Particulates pCi/m3 1.0E+01 2.0E+01 Grass or Broad Leaf Vegetation/

Vegetables or Food Products pCi/kg (wet) 1.0E+03 2.0E+03 A. A Non-routine report shall be submitted when more than one of the radionuclides listed above are detected in the sampling medium and:

1 1 2 2 3 3.... 1.0 When radionuclides other than those listed above are detected and are the result of Facility effluents, this report shall be submitted if the potential annual dose to a member of the general public is equal to or greater than the dose objectives of Part I, Section 4.1 and 4.2, of the Off-Site Dose Calculation Manual. This report is not required if the measured level of radioactivity was not the result of Facility effluents; however, in such an event, the condition shall be reported and described in the Annual Radiological Environmental Operating Report.

CH-ODCM-0001 Reference Use Page 45 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 5.2 Land Use Survey 5.2.1 Limiting Condition for Operation A. A Land Use Survey shall identify the location of the nearest milk animal, nearest meat animal, nearest vegetable garden, nearest groundwater source and the nearest residence in each of the 16 cardinal sectors within a distance of five miles. The survey shall be conducted under the following conditions:

1. Within a one-mile radius from the Facility site, enumeration by door-to-door or equivalent counting techniques.
2. Within a Five-mile radius, enumeration may be conducted door-to-door or by using referenced information from county agricultural agents or other reliable sources.

APPLICABILITY: At all times ACTION:

a.

If it is learned from this survey that milk animals, vegetable gardens and resident receptors are present at a location which yields a calculated dose greater than 20% from previously sampled location(s), the new location(s) shall be added to the monitoring program. Milk and vegetable garden sampling location(s) having the lowest calculated dose may then be dropped from the monitoring program at the end of the grazing and/or growing season during which the survey was conducted and the new location added to the monitoring program.

Groundwater monitoring is based on a determination if source(s) are potentially affected by facility operations.

Modifications to the air monitoring locations, vegetable garden sampling locations, and milk sampling locations will be made as soon as practicable. The Nuclear Regulatory Commission shall be notified of modifications to the program in the Annual Radiological Environmental Operating Report (Section 6.2).

CH-ODCM-0001 Reference Use Page 46 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 5.2.1A.2 (continued)

b.

If it is learned from this survey that a pathway for dose to a MEMBER OF THE GENERAL PUBLIC no longer exists, an additional pathway has been identified or site specific factors affecting the dose calculations for a pathway have changed, then this information should be documented in the Land Use Survey, the Annual Radiological Environmental Operating Report and the Annual Radioactive Effluent Release Report.

This information can be used to increase the accuracy of the dose models for the Annual Radioactive Effluent Release Report as well as dose estimates performed during the reporting period (i.e., quarterly dose estimates).

5.2.2 Surveillance Requirements A. A land use survey shall be conducted once per 24 months between the dates of June 1 and October 1. The results of the land use survey shall be submitted to the Nuclear Regulatory Commission in the Annual Radiological Environmental Operating Report (Section 6.2) for the year it was performed.

5.3 Interlaboratory Comparison Program 5.3.1 Limiting Condition for Operation A. Analyses shall be performed on radioactive materials as part of an Interlaboratory Comparison Program that has been approved by the Nuclear Regulatory Commission.

APPLICABILITY: At all times ACTION:

1. With analysis not being performed as required above, report the corrective actions taken to prevent a recurrence to the Commission in the Annual Radiological Environmental Operating Report (Section 6.2).

5.3.2 Surveillance Requirements A. The results of these analyses shall be included in the Annual Radiological Environmental Operating Report (Section 6.2).

CH-ODCM-0001 Reference Use Page 47 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 6.0 ADMINISTRATIVE CONTROLS 6.1 Responsibilities 6.1.1 FCS RP/Chemistry Department is responsible for the implementation and maintenance of the Off-Site Dose Calculation Manual.

6.1.2 ISFSI Shift Supervisor (ISS) is responsible for the compliance with the Off-Site Dose Calculation Manual in the operation of Fort Calhoun Station.

6.2 Radioactive Effluent Reporting Requirements The reporting requirements for radioactive effluents stated in this Section are to provide assurance that the limits set forth in Part I of the Off-Site Dose Calculation Manual are complied with. These reports will meet the requirements for documentation of radioactive effluents contained in 10 CFR Part 50.36a; Reg.

Guide 1.21, Rev. 2; and Reg. Guide 1.109, Rev. 1.

6.2.1 Annual Radioactive Effluent Release Report A report covering the operation of the Fort Calhoun Station during the previous calendar year shall be submitted prior to May 1 of each year per the requirements of QATR Appendix E, E.4.1 and 10 CFR Part 50.

The Radioactive Effluent Release Report shall include:

A. A summary of the quantities of radioactive liquid and airborne effluents and solid waste released from the facility as outlined in Regulatory Guide 1.21, Revision 2.

B. A summary of the historical average meteorological data that provides joint frequency distributions of wind direction and wind speed by atmospheric stability class will be included in the annual report.

C. An assessment of radiation doses from the radioactive liquid and airborne effluents released from the unit during each calendar quarter as outlined in Regulatory Guide 1.21, Revision 2. The assessment of radiation doses shall be performed in accordance with calculational methodology of the Regulatory Guide 1.109, Revision 1.

D. Changes to the Process Control Program (PCP) or to the Offsite Dose Calculation Manual (ODCM) made during the reporting period. Each change shall be identified by markings in the margin of the affected pages clearly indicating the area of the page that was changed and shall indicate the date the change was implemented.

CH-ODCM-0001 Reference Use Page 48 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 6.2.1 (continued)

E. A list and description of abnormal releases or abnormal discharges from the site to unrestricted areas of radioactive materials in gaseous and liquid effluents made during the reporting period.

F. An explanation of why instrumentation designated in Part I, Sections 3.1.1 and 3.2, of the Off-Site Dose Calculation Manual, was not restored to FUNCTIONAL status within 30 days.

G. A description of any major design changes or modifications made to the Liquid and/or Gaseous Radwaste Treatment Systems or Ventilation Exhaust Systems during the reporting period.

H. An explanation of why the liquid and/or gaseous radwaste treatment systems were not FUNCTIONAL, causing the limits of specifications 4.1.3A and 4.2.3A to be exceeded.

I.

The results of sampling from offsite and onsite groundwater wells per the Site Groundwater Protection Plan. [AR 39127]

J. Non-routine planned discharges (e.g., discharges from remediation efforts like pumping contaminated groundwater from a leak).

6.2.2 Annual Radiological Environmental Operating Report The Annual Radiological Environmental Operating Report for the previous one year of operation shall be submitted prior to May 1 of each year. This report contains the data gathered from the Radiological Environmental Monitoring Program. The content of the report shall include:

A. Summarized and tabulated results of the radiological environmental sampling/analysis activities. In the event that some results are not available, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted as soon as possible in a supplementary report.

B. Interpretations and statistical evaluation of the results, including an assessment of the observed impacts of the facility operation and environment.

C. The results of participation in a NRC approved Interlaboratory Comparison Program.

D. The results of land use survey required by Section 5.2.

E. A map of the current environmental monitoring sample locations.

CH-ODCM-0001 Reference Use Page 49 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 6.2.3 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report.

The Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report must be submitted within 60 days after the end of the 12-month monitoring period, per 10 CFR 72.44(d)(3).

A. A Summary of the quantity of each of the principal radionuclides released to the environment in liquid and in gaseous effluents during the previous 12 months and such other information as may be required by the Commission to estimate maximum potential radiation dose commitment to the public resulting from effluent releases.

6.2.4 Special Report If the limits or requirements of Sections 4.1.2A, 4.1.3A, 4.2.2A, 4.3.1A, and/or 5.1.1A.3 and/or 5.1.1A.4 are exceeded, a Special Report shall be issued to the Commission, pursuant to QATR Appendix E, E.2. This report shall include: [AR 39127]

A. The results of an investigation to identify the causes for exceeding the specification.

B. Define and initiate a program of action to reduce levels to within the specification limits.

C. The report shall also include an evaluation of any release conditions, environmental factors, or other aspects necessary to explain the condition.

6.2.5 EPA 40 CFR Part 190 Reporting Requirements With the calculated dose from the release of radioactive materials in liquid or gaseous effluents exceeding twice the limits of dose from specifications 4.1.2A or 4.2.2A, calculations shall be made including direct radiation calculations, to prepare and submit a special report to the Commission within 30 days and limit the subsequent releases such that the dose to any real individual from uranium fuel cycle sources is limited to 25 mrem to the total body or any organ (except thyroid, which is limited to 75 mrem) over the calendar year. This special report shall include an analysis which demonstrates that radiation exposures to any member of the public from uranium fuel cycle sources (including all effluent pathways and direct radiation) are less than the 40 CFR Part 190 standard. Otherwise, obtain a variance from the Commission to permit releases which exceed the 40 CFR Part 190 standard. The submittal of the report is to be considered a timely request and a variance is granted pending the final action on the variance request from the Commission.

CH-ODCM-0001 Reference Use Page 50 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 6.2.6 ISFSI 10 CFR Part 72.104 Reporting Requirements The regulatory requirements of 10CFR20, 10CFR72 and 40CFR190 each limit total dose to individual members of the public without regard to specific pathways. The only significant exposure pathways for light water reactors included in 10CFR20, 10CFR72 and 40CFR190 not addressed by 10CFR50 Appendix I are the direct radiation pathway and exposure from on-site activity by members of the public.

The 10CFR72.104 dose limits are the same as those specified in 40CFR190.

ISFSI dose contribution is in the form of direct radiation as no liquid or gas releases are expected to occur. If the dose limits of 40CFR190 or 10CFR72.104 are exceeded, a special report to the NRC, as well as an appropriate request for exemption/variance, is required to be submitted to the NRC.

The requirement that the dose limits of 10CFR72.104 apply to any real individual is controlled for ISFSI activities in the ISFSI 72.212 report.

Therefore, for the purposes of analyzing dose from the ISFSI, the member of the public as defined in 40CFR190 is the same as for the real individual.

The external Total Body Dose is comprised of:

1) Total Body Dose due to noble gas radionuclides in gaseous effluents
2) Dose due to radioactive waste and the ISFSI
3) Total Body Dose due to radioactivity deposited on the ground (this dose is accounted for in the determination of the non-noble gas dose and is not considered here)

CH-ODCM-0001 Reference Use Page 51 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Dose from onsite storage (such as the ISFSI) is given by:

D,osf = max of :

(TLD dose from indicator TLD i - average of all background TLDs)

  • occupancy factor at TLD i Neutron dose is found by multiplying gamma dose by a neutron/gamma ratio determined from other site TLDs around the ISFSI.

The Total Body Dose, external is given by:

D,ext = D,tb + D,osf Where D,ext is the external dose D,tb is the total body dose D,osf is the dose from on-site storage The Total Dose is then given by:

D,tot = D,ext + D,liq + D,nng Where D,tot is the total dose D,ext is the external dose D,liq is the dose from liquid effluents D,nng is the dose from non-noble gases Dose Limits Total Body, annual 25 mrem Thyroid, annual 75 mrem Other Organs, annual 25 mrem

CH-ODCM-0001 Reference Use Page 52 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 6.3 Change Mechanism The Off-Site Dose Calculation Manual is the controlling document for all radioactive effluent releases. It is defined as a procedure under the guidance of QATR Section 5.

It will be revised and reviewed by an Independent Safety Review (ISR) and approved by the Plant Manager in accordance with QATR Appendix E, E.1.2. All changes to the Off-Site Dose Calculation Manual will be forwarded to the Nuclear Regulatory Commission during the next reporting period for the Annual Radioactive Effluent Release Report in accordance with the requirements of QATR Appendix E, E.1.2.

6.4 Meteorological Data The 5 year historical Average /Q is utilized to determine the concentrations of radionuclides at the unrestricted area boundary. It is also the factor used in conjunction with the parameters and methodologies in Part II, of the Off-Site Dose Calculation Manual to determine unrestricted area dose on a quarterly bases or as needed. It is based on an average of the highest calculated sector /Q values, using all 16 sectors for previous multiple years Annual Radioactive Effluent Release Reports, and the XOQDOQ plume trajectory model. An additional 10 percent will be added to the average for unrestricted area dose estimates performed quarterly for conservatism. XOQDOQ model conforms with the Nuclear Regulatory Commissions Regulatory Guide 1.111.

Historical average meteorological data will be utilized in the preparation of the Annual Radioactive Effluent Release Report. Prior years of data is used to calculate the joint frequency table, the dispersion coefficients and deposition factors in all 16 sectors.

These are used in the calculation of doses to individuals in unrestricted areas as a result of the operation of Fort Calhoun Station. The models used, GASPAR 2 and LADTAP 2, meet the intent of Nuclear Regulatory Commissions Reg. Guide 1.109 and 1.21 for the reporting of doses due to routine radioactive effluent releases.

CH-ODCM-0001 Reference Use Page 53 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 6.5 References 6.5.1 Regulatory Guide 1.109, Rev. 1 - Calculation of Annual Dose to man from Routine Releases of Reactor Effluents for the purpose of evaluation compliance with 10 CFR Part 50, Appendix I 6.5.2 Regulatory Guide 1.111, Rev. 1 - Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors.

6.5.3 Regulatory Guide 1.113, Rev. 1 - Estimating Aquatic Dispersion of Effluents from Accidental and Routine Releases for the purpose of Implementing Appendix I.

6.5.4 NRC Branch Technical Position, March 1978 6.5.5 NUREG-0133 - Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants.

6.5.6 NUREG-1301 - Offsite Dose Calculation Manual Guidance.

6.5.7 Regulatory Guide 1.21, Rev. 2 - Measuring, Evaluating, and Reporting Radioactivity in solid wastes and Releases of Radioactivity Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants.

6.5.8 Code of Federal Regulations, Title 10, Part 20 6.5.9 Code of Federal Regulations, Title 10, Part 50 6.5.10 Code of Federal Regulations, Title 10, Part 72 6.5.11 Code of Federal Regulations, Title 40, Part 190 6.5.12 Fort Calhoun Revised Environmental Report (Unit No. 1)-1972 6.5.13 NO-FC-10, Quality Assurance Topical Report 6.5.14 Defueled Safety Analysis Report 6.5.15 AR 12357, Implement Recommendations of Memo FC-0133-92, Part I, Table 3.2.1 Action 4, of the Off-Site Calculation Manual 6.5.16 AR 39127, NEI Industry Initiative on Groundwater Protection

CH-ODCM-0001 Reference Use Page 54 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 6.5.17 Regulatory Guide 4.1, Rev. 2 - Radiological Environmental Monitoring for Nuclear Power Plants 6.5.18 FC-19-001, ODCM rev 29 Change Support Document 6.5.19 FC-18-005, Habits of the Real Individual in Vicinity of Fort Calhoun Station, X/Q, Direct Radiation Dose Calculation

CH-ODCM-0001 Reference Use Page 55 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 7.0 BASIS 7.1 Instrumentation 7.1.1 Radioactive Liquid Effluent Instrumentation The Radioactive liquid effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive material in liquid effluents during actual or potential releases of liquid effluents. The Alarm/Trip setpoints for these instruments shall be calculated in accordance with Part II of the Offsite Dose Calculation Manual to ensure that the alarm/trip will occur prior to exceeding the limits of 10 CFR Part 20. The FUNCTIONALITY and use of this instrumentation is consistent with the requirements of DSAR-Appendix G Criterion 17 - Monitoring Radioactive Releases, Criterion 18 -

Monitoring Fuel and Waste Storage, and Criterion 70 - Control of Release of Radioactivity to the Environment.

7.1.2 Radioactive Gaseous Effluent Instrumentation The Radioactive gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive material in gaseous effluents during actual or potential releases of gaseous effluents.

7.2 Radioactive Effluents 7.2.1 Radioactive Liquid Effluents A. Concentration This specification is provided to ensure that the concentration of radioactive materials released in liquid waste effluents from the site to unrestricted areas will be less than 10 times the concentration levels specified in 10 CFR Part 20, Appendix B, Table II, Column 2. This limitation provides additional assurance that the levels of radioactive materials in bodies of water outside the site will result in exposures within (1) the Section II.A design objectives of Appendix I, 10 CFR Part 50, and (2) the limits of 10 CFR Part 20.1001-20.2401 to the population.

CH-ODCM-0001 Reference Use Page 56 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

B. Dose This specification is provided to implement the requirements of Sections II.A, III.A and IV.A of Appendix I, 10 CFR Part 50. The Limiting Condition for Operation implements the guides set forth in Section II.A of Appendix I. The ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents will be kept "as low as is reasonably achievable". Also, with fresh water sites with drinking water supplies which can be potentially affected by facility operations, there is reasonable assurance that the operation of the facility will not result in radionuclide concentrations in the finished drinking water that are in excess of the requirements of 40 CFR Part 141. The dose calculation methodology and parameters in Part II of the Off-Site Dose Calculation Manual, implement the requirements in Section III.A that conformance with the guides of Appendix I is to be shown by calculational procedures based on models and data such that the actual exposure of an individual through appropriate pathways is unlikely to be substantially underestimated. The equations specified in Part II of the Off-Site Dose Calculation Manual, for calculating the doses due to the actual release rates of radioactive material in liquid effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I,"

Revision 1, October 1977, and Regulatory Guide 1.113, "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," April 1977.

C. Liquid Waste Treatment System The FUNCTIONALITY of the liquid radwaste treatment system ensures that this system will be available for use whenever liquid effluents require treatment prior to release to the environment. The requirement that appropriate portions of this system be used when specified provides assurance that the releases of radioactive materials in liquid effluents will be kept "as low as is reasonably achievable". This specification implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50 and design objective and in Section II.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the liquid radwaste treatment system were specified to ensure the design objectives set forth in Section II.A of Appendix I, 10 CFR Part 50 for liquid effluents are not exceeded.

CH-ODCM-0001 Reference Use Page 57 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

D. Liquid Holdup Tanks Restricting the quantity of radioactive material contained in the specified tanks provides assurance that in the event of an uncontrolled release of the tanks contents, the resulting concentrations would be less than the limits of 10 CFR Part 20, Appendix B, Table II, Column 2, at the nearest potable water supply and the nearest surface water supply in an unrestricted area.

7.2.2 Radioactive Gaseous Effluents A. Concentration This specification, in conjunction with Steps 4.2.2A, is provided to ensure that the dose at or beyond the Site Boundary from gaseous effluents will be within the annual dose limits of 10 CFR Part 20 for MEMBERS OF THE PUBLIC. The release rate of radioactive material in airborne effluents shall be controlled such that the instantaneous concentrations for these radionuclides do not exceed the values specified in 10 CFR Part 20 for airborne effluents at the unrestricted area boundary.

CH-ODCM-0001 Reference Use Page 58 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

B. Dose - Radioactive Material in Particulate Form with Half-Lives Greater than Eight Days (Other than Noble Gases) and Tritium This specification is provided to implement the requirements of Sections II.C, III.A and IV.A of Appendix I, 10 CFR Part 50. The Limiting Condition For Operation implements the guides set forth in Section II.C of Appendix I. The ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I assure that the releases of radioactive material in gaseous effluents will be kept as low as is reasonably achievable. The surveillance requirements implement the requirements in Section III.A of Appendix I that conform with the guides of Appendix I to be shown by calculational procedures based on models and data such that the actual exposure of an individual through the appropriate pathways is unlikely to be substantially underestimated. The release rate specification for radioactive material in particulate form with half-lives greater than eight days (other than noble gases) and tritium are dependent on the existing radionuclide pathways to man in the areas at or beyond the site boundary. The pathways that were examined in the development of these calculations were: 1) individual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man, and 4) deposition on the ground with subsequent exposure of man.

C. Gaseous Waste Treatment The FUNCTIONALITY of the ventilation exhaust treatment systems ensures that the systems will be available for use whenever gaseous effluents require treatment prior to release to the environment. The requirement that appropriate portions of this system be used when specified provides assurance that the releases of radioactive materials in gaseous effluents will be kept as low as is reasonably achievable. This specification implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50 and design objective and in Section II.D of Appendix I to 10 CFR Part 50.

The specified limits governing the use of appropriate portions of the systems were specified to ensure the design objectives set forth in Section II.B and II.C of Appendix I, 10 CFR Part 50 for gaseous effluents are not exceeded.

CH-ODCM-0001 Reference Use Page 59 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

D. Total Dose - Uranium Fuel Cycle This specification is provided to meet the dose limitations of 40 CFR Part 190 that have been incorporated into 10 CFR Part 20.1301(d). This requires the preparation and submittal of a Special Report whenever the calculated doses due to releases of radioactivity and to radiation from uranium fuel cycle sources exceed 25 mRems to the total body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mRems. It is highly unlikely that the resultant dose to a MEMBER OF THE PUBLIC will exceed the dose limits of 40 CFR Part 190 if the facility remains within twice the dose design objectives of Appendix I, 10 CFR Part 50, and if direct radiation doses (including outside storage tanks, etc.) are kept small. The Special Report shall describe a course of action that should result in the limitation of the annual dose to a MEMBER OF THE PUBLIC to within the 40 CFR Part 190 limits. For purposes of the Special Report, it may be assumed that the dose commitment to the MEMBER OF THE PUBLIC from other uranium fuel cycle sources is negligible, with the exception that dose contributions from other nuclear fuel cycle facilities at the same site or within a radius of 8 km must be considered. If the dose to any MEMBER OF THE PUBLIC is estimated to exceed the requirements of 40 CFR Part 190, the Special Report, with a request for a variance (provided the release conditions resulting in violation of 40 CFR Part 190 have not already been corrected), in accordance with the provisions of 40 CFR Part 190.11 and 10 CFR Part 20.2203(a)(4) and 20.2203(b) is considered to be a timely request and fulfills the requirements 40 CFR Part 190 until NRC staff action is completed. The variance only relates to the limits of 40 CFR Part 190, and does not apply in any way to the other requirements for dose limitation of 10 CFR Part 20. An individual is not considered a MEMBER OF THE PUBLIC during any period in which he/she is engaged in carrying out any operation that is part of the nuclear fuel cycle. Demonstration of compliance with the limits of 40 CFR Part 190 or with the design objectives of Appendix I to 10 CFR Part 50 will be considered to demonstrate compliance with the 0.1 rem limit of 10 CFR Part 20.1301.

CH-ODCM-0001 Reference Use Page 60 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 7.3 Radiological Environmental Monitoring 7.3.1 Monitoring Program The radiological environmental monitoring program required by this specification provides measurements of radiation and radioactive materials in those exposure pathways and for radionuclides which lead to the highest potential radiation exposures of individuals resulting from the station operation. This monitoring program thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and modeling of the environmental exposure pathways. The initially specified monitoring program was effective for at least the first three years of commercial operation.

Following this period, program changes are initiated based on operational experience.

7.3.2 Land Use Survey This specification is provided to ensure that changes in the use of unrestricted areas are identified and that modifications to the monitoring program are made if required by the results of this survey. The frequency of the Land Use Survey has been reduced to a biennial requirement in site procedures because persons knowledgeable in land use census monitor usage characteristics perform routine REMP sampling. This approach allows knowledge gained during sample collection to be integrated into the program, maintaining its effectiveness. The best survey information from door to door, aerial or consulting with local agricultural authorities, or equivalent, shall be used. This survey satisfies the requirements of Section IV.B.3 of Appendix I to 10 CFR Part 50. Restricting the survey to gardens of greater than 500 square feet provides assurance that significant exposure pathways via leafy vegetables will be identified and monitored since a garden of this size is the minimum required to produce the quantity (26 kg/year) of leafy vegetables assumed in Regulatory Guide 1.109 for consumption by a child.

To determine this minimum garden size, the following assumptions were used, 1) that 20% of the garden was used for growing broad leaf vegetation (i.e., similar to lettuce and cabbage), and 2) a vegetation yield of 2 kg/m2.

For milk, the survey is restricted to only milk animals (cow or goat) producing milk for human consumption. Air monitoring stations are strategically located to monitor the resident receptors who could potentially receive the highest doses from airborne radioactive material. For groundwater, samples shall be taken when sources are determined to potentially be affected by facility operations, and when sources are tapped for drinking or irrigation purposes in areas where the hydraulic gradient or recharge properties are suitable for contamination. Guidance provided in the Branch Technical Position and QATR Appendix E, E.3.1.3 is used to meet the intent of NUREG-1301.

CH-ODCM-0001 Reference Use Page 61 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 7.3.3 Interlaboratory Comparison Program The requirement for participation in an Interlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of a quality assurance program for environmental monitoring in order to demonstrate that the results are reasonably valid for the purposes of Section IV.B.2 of Appendix I to 10 CFR Part 50.

7.4 Abnormal Release or Abnormal Discharge Reporting 7.4.1 Specific information should be reported concerning abnormal (airborne and/or liquid) releases on site and abnormal discharges to the unrestricted area. The report should describe each event in a way that would enable the NRC to adequately understand how the material was released and if there was a discharge to the unrestricted area. The report should describe the potential impact on the ingestion exposure pathway involving surface water and ground water, as applicable. The report should also describe the impact (if any) on other affected exposure pathways (e.g., inhalation from pond evaporation).

7.4.2 The following are the thresholds for reporting abnormal releases and abnormal discharges in the supplemental information section:

A. Abnormal release or Abnormal Discharges that are voluntarily reported to local authorities under NEI 07-07, Industry Ground Water Protection Initiative. [AR 39127]

B. Abnormal release or Abnormal discharges estimated to exceed 100 gallons of radioactive liquid where the presence of licensed radioactive material is positively identified (either in the on-site environs or in the source of the leak or spill) as greater than the minimum detectable activity for the laboratory instrumentation.

C. Abnormal releases to on-site areas that result in detectable residual radioactivity after remediation.

D. Abnormal releases that result in a high effluent radiation alarm without an anticipated trip occurring.

E. Abnormal discharges to an unrestricted area.

CH-ODCM-0001 Reference Use Page 62 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 7.4.3 Information on Abnormal releases or Abnormal discharges should include the following, as applicable:

Date and duration Location Volume Estimated activity of each radionuclide Effluent monitoring results (if any)

On-site monitoring results (is any)

Depth to the local water table Classification(s) of subsurface aquifer(s) (e.g., drinking water, unfit for drinking water, not used for drinking water)

Size and extent of any ground water plume Expected movement/mobility of any ground water plume Land use characteristics (e.g., water used for irrigation)

Remedial actions considered or taken and results obtained Calculated member of the public dose attributable to the release Calculated member of the public dose attributable to the discharge Actions taken to prevent recurrence, as applicable Whether the NRC was notified, the date(s), and the contact organization

CH-ODCM-0001 Reference Use Page 63 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

PART II CALCULATIONS

CH-ODCM-0001 Reference Use Page 64 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 1.0 EFFLUENT MONITOR SETPOINTS 1.1 Liquid Effluents 1.1.1 There is one liquid discharge pathway to the Missouri River. This pathway empties into the circulating water system which discharges to the Missouri River (see Figure 1).

1.1.2 The flowrate for dilution water varies with the number dilution pumps in service 1.1.3 QATR Appendix E, E.2.1.3.b establishes the administrative control limit on concentration of radioactive material, other than dissolved or entrained noble gases, released in liquid effluents to unrestricted areas conforming to ten times 10 CFR Part 20.1001-20.2401, Appendix B, Table 2, Column 2.

1.1.4 The liquid effluent monitoring instrumentation ALERT setpoints shall be established low enough to ensure that the concentration of radioactive material released in liquid effluents at site discharge will be less than the concentrations specified in 10 CFR Part 20, Appendix B, Table 2, Column 2.

1.1.5 The liquid effluent monitoring instrumentation HIGH ALARM setpoints shall be established low enough to ensure that the concentration of radioactive material released in liquid effluents at site discharge will be less than 10 times the concentrations specified in 10 CFR Part 20, Appendix B, Table 2, Column 2.

1.1.6 Cs-137 is used to calibrate the liquid effluent monitors.

CH-ODCM-0001 Reference Use Page 65 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 1.1.7 Liquid Effluent Radiation Monitor A. Overboard Discharge Header Monitor (RM-055)

1. This process radiation monitor provides control of the waste tank effluent by monitoring the overboard header prior to its discharge into the circulating water discharge tunnel. The concentration of activity at discharge is controlled below ten times the 10 CFR Part 20 limit of 1.0E-06 Ci/ml at site discharge for unidentified isotopes by the high alarm setpoint which closes the overboard flow control valve.
2. The following calculations for maximum concentration and alarm setpoints are valid for radioactive liquid releases of tank discharge.
3. The maximum allowable concentration in the overboard discharge header is:

1.005

Where:

1.0E-05 Ci/ml = Ten times 10 CFR Part 20 Limit for unidentified radionuclides at site discharge (10 CFR Part 20, Appendix B, Note 2).

F

= Total dilution flow in the discharge tunnel (gpm).

f

= Maximum tank discharge flow rate (gpm).

CMAX

= Maximum allowable activity in discharge header (Ci/ml).

CH-ODCM-0001 Reference Use Page 66 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 1.1.7A (continued)

The High Alarm Setpoint (CPM):

0.75 Where:

0.75

= An administrative correction factor which includes the following:

25% tolerance to account for the difference in detector sensitivity for the range of isotopes detected.

Sf

= Detector sensitivity factor (CPM/Ci/ml). (Sensitivity based on Cs-137).

K3

= Allocation factor for Waste Liquid Releases (1)

CMAX

= Maximum allowable concentration in discharge header (Ci/ml).

B

= Background (CPM)

The Alert Setpoint will be chosen less than or equal to one tenth (1/10) the value of the high alarm setpoint value so that significant increases in activity will be identified prior to exceeding an Unrestricted Area fractional sum of 1.0. It will also provide additional time for corrective actions prior to exceeding the Alarm Setpoint.

CH-ODCM-0001 Reference Use Page 67 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 1.2 Airborne Effluents 1.2.1 There are multiple air effluent discharge pathways at the Fort Calhoun Station during decommissioning with three different mechanisms of release:

Forced draft ventilation, Unventilated building release, and Open-air demolition.

Forced draft ventilation uses installed or portable filtered ventilation units with a fan with a rated cfm as the release rate. Monitoring of forced draft ventilation includes utilizing presently installed system monitors such as RM-052, and RM-043. When portable ventilation systems are used, the air particulate sample head shall directly sample the airborne effluent discharge flowpath.

Unventilated building releases in which the dimension of an open doorway coupled with windspeed blowing through the doorway are used to calculate the release rate. Unventilated building releases shall be monitored with a portable air sampler located outside of the doorway at any time the door is open, and active decommissioning that could generate airborne is in progress.

Open-air demolition releases are rubble and building debris containing low level radioactive material may be wind-blown as a release. Other Open-air releases may include building demolition in which the structure of the building is demolished to the point where it becomes inaccurate to use doorway area as a release point each location shall be documented as they are established. Airborne effluent monitoring during Open-air demolition shall be accomplished by placing 4 air samplers in 4 general opposing directions around the area to be sampled, placed in areas that will not obstruct decommissioning activities around the area.

Table 1 - Deleted

CH-ODCM-0001 Reference Use Page 68 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Figure 1 - Exclusion and Site Boundary Map

CH-ODCM-0001 Reference Use Page 69 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Figure 2 - Deleted Figure 3 - Deleted Figure 4 - Airborne Effluent Discharge Pathways

CH-ODCM-0001 Reference Use Page 70 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Figure 4 - Airborne Effluent Discharge Pathways (continued)

FORCED DRAFT AIR SAMPLER WITH EXHAUST TRUNK DISCHARGE FORCED DRAFT AIR SAMPLER WITH OUTLET PLENUM

CH-ODCM-0001 Reference Use Page 71 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

UNVENTILATED BUILDING RELEASE AIR SAMPLERS Figure 4 - Airborne Effluent Discharge Pathways (continued)

OPEN-AIR DEMOLITION AIR SAMPLERS

CH-ODCM-0001 Reference Use Page 72 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Figure 5 - Airborne Radioactive Waste Disposal System

CH-ODCM-0001 Reference Use Page 73 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 2.0 EFFLUENT CONCENTRATIONS 2.1 Liquid Effluent Concentrations 2.1.1 The concentration of radioactive material in liquid effluents, after dilution, will be limited to the concentrations as specified in 10 CFR Part 20, Appendix B, Table 2, Column 2. For liquid releases the analyses will be performed in accordance with Part I, Table 4.1, of the Off-Site Dose Calculation Manual, and the concentration of each radionuclide at site discharge will be calculated, based on the following equation:

1

Radionuclide concentration at site discharge:

Where:

Ai

= concentration at site discharge for radionuclide (I), in Ci/ml.

ai

= concentration of radionuclide (I) in the undiluted effluent, in Ci/ml.

f

= undiluted effluent flowrate, in gpm.

F

= total diluted effluent flowrate in gpm.

weci = water effluent concentration limit for radionuclide (I) per 10 CFR Part 20, Appendix B, Table 2, Column 2.

i NOTE i

In addition to the above defined method, Notes 1 through 4 of 10 CFR Part 20, Appendix B, will also be applicable.

2.2 Airborne Effluent Concentrations 2.2.1 The concentration at the unrestricted area boundary, due to airborne effluent releases, will be limited to less than Appendix B, Table 2, Column 1, values.

2.2.2 To determine the concentration and air effluent concentration (aec) fraction summation at the unrestricted area boundary, the following equations will be used:

CH-ODCM-0001 Reference Use Page 74 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

1

Where:

Ai

= Concentration of radionuclide (I) at the unrestricted area boundary K0

= Constant of unit conversion. (1.0E-6 m3/cc)

ECLi = Effluent concentration limit (10 CFR Part 20, Appendix B, Table 2, Column 1 value for radionuclide(I))

Qi

= The release rate of radionuclide (I) in airborne effluents from all vent releases (in Ci/sec.)

(/Q) = Annual Average Dispersion Factor at the Unrestricted Area Boundary from Part II, Table 4, of the Off-Site Dose Calculation Manual.

2.2.3 As appropriate, simultaneous releases from all release pathways will be considered in evaluating compliance with the release rate limits of 10 CFR Part 20. Historical annual average dispersion parameters, as presented in Table 4, may be used for evaluating the airborne effluent dose rate.

CH-ODCM-0001 Reference Use Page 75 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.0 RADIOACTIVE EFFLUENT DOSE CALCULATIONS 3.1 Liquid Effluent Dose Calculations 3.1.1 Three pathways for human exposure to liquid releases from FCS to the Missouri River exists: 1) fish, 2) drinking water, and 3) Shoreline deposition.

Fish are considered to be taken from the vicinity of the facility discharge.

The drinking water for Omaha is located 19 miles downstream from FCS.

The dilution factors for these pathways are derived from the Revised Environmental Report for FCS, (1974), (page 4-29 and 4-31). This report states that during Low-Low river conditions, the concentration at Omaha's water intake will be < 14% of the concentration at discharge from FCS and will average 3%. This equates to a dilution factor of 7.14, which is used to calculate the maximum dose to an individual from liquid pathways and a dilution factor of 33.33, for calculating the average dose. All pathways combine to give the dose to an individual in unrestricted areas.

3.1.2 10 CFR Part 50, Appendix I restricts the dose to individuals in the unrestricted areas from radioactive materials in liquid effluents from the Fort Calhoun Station to the following limits:

during any calendar quarter 1.5 mrem to total body 5.0 mrem to any organ and during any calendar year 3.0 mrem to total body 10.0 mrem to any organ The following calculational methods shall be used for determining the dose or dose commitment from liquid effluents.

CH-ODCM-0001 Reference Use Page 76 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.1.3 Doses from Liquid Effluent Pathways A. Potable Water 1100

exp

Where:

Rapj

= is the total annual dose to organ(j) of individuals of age group (a) from all of the radionuclides (I) in pathway (p), in mrem/yr.

Uap

= is a usage factor that specifies the intake rate for an individual of age group (a) associated with pathway (p), in

/yr. (Table 6)

Mp

= is the mixing ratio (reciprocal of the dilution factor) at the point of withdrawal of drinking water, dimensionless.

(Table 17)

F

= is the flow rate of the liquid effluent, in ft3/ sec.

Qi

= is the annual release rate of radionuclide (I), in Ci/yr.

Daipj

= is the dose factor specific to a given age group (a),

radionuclide (I), pathway (p), and organ (j) which can be used to calculate the radiation dose from an intake of a radionuclide, in mrem/pCi. (Tables 13-16) i

= is the radiological decay constant of radionuclide (I), in hr 1.

tp

= is the average transit time required for radionuclides to reach the point of exposure. For internal dose, tp is the total time elapsed between release of the radionuclides and ingestion of water, in hours. (Table 17) 1100

= Constant (pCi

  • yr
  • ft3/Ci
  • sec
  • L)

CH-ODCM-0001 Reference Use Page 77 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.1.3 (continued)

B. Aquatic Foods 1100

exp

Where:

Rapj

= is the total annual dose to organ (j) of individuals of age group (a) from all of the radionuclides (I) in pathway (p), in mrem/yr.

Uap

= is a usage factor that specifies the intake rate for an individual of age group (a) associated with pathway (p), in kg/yr. (Table 6)

Mp

= is the mixing ratio (reciprocal of the dilution factor) at the point of harvest of aquatic food, dimensionless. (Table 17)

F

= is the flow rate of the liquid effluent, in ft3/sec.

Qi

= is the annual release rate of radionuclide (I), in Ci/yr.

Bip

= is the equilibrium bioaccumulation factor for radionuclide (I) in pathway (p) expressed as the ratio of the concentration in biota (in pCi/kg) to the radionuclide concentration in water (in pCi/liter), in (pCi/kg)/(pCi/liter). (Table 3)

Daipj

= is the dose factor specific to a given age group (a),

radionuclide (I), pathway (p), and organ (j), which can be used to calculate the radiation dose from an intake of a radionuclide, in mrem/pCi. (Tables 13-16) i

= is the radiological decay constant of radionuclide (I), in hr-1.

tp

= is the average transit time required for radionuclides to reach the point of exposure. For internal dose, tp is the total time elapsed between release of the radionuclides and ingestion of food, in hours. (Table 17) 1100

= Constant (pCi

  • yr
  • ft3/Ci
  • sec
  • L)

CH-ODCM-0001 Reference Use Page 78 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.1.3 (continued)

C. Shoreline Deposits 110,000

exp 1 exp

Where:

Rapj

= is the total annual dose to organ (j) of individuals of age group (a) from all of the radionuclides (I) in pathway (p),

in mrem/yr.

Uap

= is a usage factor that specifies the exposure time for an individual of age group (a) associated with pathway (p),

in hr/yr. (Table 6)

Mp

= is the mixing ratio (reciprocal of the dilution factor) at the point of exposure, dimensionless. (Table 17)

W

= is the shore-width factor, dimensionless. (Table 17)

F

= is the flow rate of the liquid effluent, in ft3/sec.

Qi

= is the annual release rate of radionuclide (I), in Ci/yr.

Tip

= is the radioactive half life of radionuclide (I), in days.

Daipj

= is the dose factor specific radionuclide (I) which can be used to calculate the radiation dose from exposure to a given concentration of a radionuclide in sediment, expressed as a ratio of the dose rate (in mrem/hr) and the real radionuclide concentration (in pCi/m2). (Table 8) i

= is the radiological decay constant of radionuclide (I), in hr-1.

tp

= is the average transit time required for radionuclides to reach the point of exposure, in hours. (Table 17) tb

= is the period of time for which sediment or soil is exposed to the contaminated water, in hours. (Table 17) 110,000 = Constant [(100

  • pCi
  • yr
  • ft3)/(Ci
  • sec
  • L)]

CH-ODCM-0001 Reference Use Page 79 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.2 Airborne Effluent Dose Calculations 3.2.1 Radioiodine, Tritium, and Particulates 10 CFR Part 50, Appendix I, restricts the dose to individuals in the unrestricted areas from radioactive materials in gaseous airborne from the Fort Calhoun Station to:

During any calendar quarter 7.5 mrem to any organ and During any calendar year 15 mrem to any organ The dose to an individual from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than 8 days in airborne effluents released to unrestricted areas should be determined by the following expressions:

CH-ODCM-0001 Reference Use Page 80 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) i NOTE i

In all cases, for releases of tritium, use the dispersion parameter for inhalation (/Q).

A. Annual Organ Dose from External Irradiation from Radioactivity Deposited on the Ground Plane The ground plane concentration of radionuclide (I) at distance r, in the sector at angle, with respect to the release point, may be determined by:

1.010,

1 exp Where:

CGI

= is the ground plane concentration of the radionuclide (I) at distance r, in the sector at angle, from the release point, in pCi/m2.

Qi

= is the annual release rate of radionuclide (I) to the atmosphere, in Ci/yr.

tb

= is the time period over which the accumulation is evaluated, which is assumed to be 20 years (mid-point of plant operating life). (Table 17) i(r,)

= is the annual average relative deposition of radionuclide (I) at distance r, in the sector at angle, considering depletion of the plume by deposition during transport, in m-2. Table 4 i

= is the radiological decay constant for radionuclide (I), in yr-1.

1.0x1012

= is the number of pCi/Ci

CH-ODCM-0001 Reference Use Page 81 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

The annual organ dose is then calculated using the following equation:

, 8760

Where:

CGj(r,)

= is the ground plane concentration of radionuclide (i) at distance r, in the sector at angle, in pCi/m2.

DFGij

= is the open field ground plane dose conversion factor for organ (j) from radionuclide (i), in mrem-m2/pCi-hr.

(Table 8)

DGj(r,)

= is the annual dose to the organ (j) at distance r, in the sector at angle, in mrem/yr.

Sf

= is the shielding factor that accounts for the dose reduction due to shielding provided by residential structures during occupancy, dimensionless. (Table 17) 8760

= is the number of hours in a year B. Annual Dose from Inhalation of Radionuclides in Air The annual average airborne concentration of radionuclide (i) at distance r, in the sector at angle, with respect to the release point, may be determined as:

, 3.17 10 Where:

Qi

= is the annual release rate of radionuclide (i) to the atmosphere, in Ci/yr.

i(r,)

= is the annual average ground-level concentration of radionuclide (i) in air at distance r, in the sector at angle

, in pCi/m3.

[/Q]D (r,)

= is the annual average atmosphere dispersion factor, in sec/m3 (see Reg Guide 1.111). This includes depletion (for radioiodines and particulates) and radiological decay of the plume. (Table 4) 3.17x104

= is the number of pCi/Ci divided by the number of sec/yr.

CH-ODCM-0001 Reference Use Page 82 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

The annual dose associated with inhalation of all radionuclides to organ (j) of an individual in age group (a), is then:

Where:

DAja(r,)

= is the annual dose to organ (j) of an individual in the age group (a) at distance r, in the sector at angle, due to inhalation, in mrem/yr.

Ra

= is the annual air intake for individuals in the age group (a), in m3/yr. (Table 6) i(r,)

= is the annual average ground-level concentration of radionuclide (i) in air at distance r, in the sector at angle

, in pCi/m3.

DFAija

= is the inhalation dose factor for radionuclide (i), organ (j), and age group (a), in mrem/pCi. (Tables 9-12)

CH-ODCM-0001 Reference Use Page 83 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.2.2 Concentrations of Radionuclides in Foods and Vegetation from Atmospheric Releases A. Parameters for Calculating Concentrations in Forage, Produce, and Leafy Vegetables, excluding Tritium

,, 1 exp

1 exp

exp Where:

CVi(r,)

= is the concentration of radionuclide (i) in and on vegetation at distance r, in the sector at angle, in pCi/kg.

di (r,)

= is the deposition rate of radionuclide (i) at distance r, in the sector at angle, in pCi/m2 hr.

r

= is the fraction of deposited activity retained on crops, dimensionless. (Table 17)

Ei

= is the effective removal rate constant for radionuclide (i) from crops, in hr-1.

Ei = i + w w = 0.0021/hr. (Table 17) te

= is the time period that crops are exposed to contamination during the growing season, in hours.

(Table 17)

Yv

= is the agricultural productivity (yield) in kg (wet weight)/m2. (Table 17)

Biv

= is the concentration factor for uptake of radionuclide (i) from soil by edible parts of crops, in pCi/ kg (wet weight) per pCi/kg dry soil. (Table 5) i

= is the radiological decay constant of radionuclide (I), in hr-1 tb

= is the period of time for which sediment or soil is exposed to the contaminated water, in hours (mid-point of plant life). (Table 17)

P

= is the effective "surface density" for soil, in kg (dry soil)/m2. (Table 17) th

= is the holdup time that represents the time interval between harvest and consumption of the food, in hours.

(Table 17)

Different values for the parameters te, Yv, and th, may be used to allow the use of the Equation for different purposes: estimating concentrations in produce consumed by man; in leafy vegetables consumed by man; in forage consumed directly as pasture grass by dairy cows, beef cattle, or goats; and in forage consumed as stored feed by dairy cows, beef cattle or goats. See Table 17.

CH-ODCM-0001 Reference Use Page 84 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

The deposition rate from the plume is defined by (Reg. Guide 1.109, Rev. 1, Page 1.109-26, Equa. C-6):

, 1.1 10,

Where:

di(r,)

= is the deposition rate of radionuclide (i).

i(r,)

= is the relative deposition of radionuclide (i), considering depletion and decay, in m-2 (see Reg Guide 1.111).

(Table 4) 1.1x108

= is the number of pCi/Ci (1012) divided by the number of hours per year (8760).

Qi

= is the annual release rate of radionuclide (i) to the atmosphere, in Ci/yr.

CH-ODCM-0001 Reference Use Page 85 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

B. For radioiodines, the model considers only the elemental fraction of the effluent:

, 3.3 10,

Where:

di (r, )

= The deposition rate of radioiodine (i).

3.3 x 107

= The number of pCi/Ci (1012) divided by the number of hours per year (8760), then multiplied by the amount of radioiodine emissions considered to be elemental (0.5).

i (r, )

= The relative deposition of radioiodine (i), considering depletion and decay, in m-2. (Table 4)

Qi

= The total (elemental and nonelemental) radioiodine (i) emission rate.

C. Parameters for Calculating the Concentration of Radionuclide (i) in the Animal's Feed (Milk Cow, Beef Cow, and Goat)

, 1

, 1 Where:

CVi (r,)

= is the concentration of radionuclide (i) in the animal's feed, in pCi/kg.

CPi(r,)

= is the concentration of radionuclide (i) on pasture grass (calculated using Equation 3.2.3A with th=0), in pCi/kg.

CSi(r,)

= is the concentration of radionuclide (i) in stored feeds (calculated using Equation 3.2.3A with th=90 days), in pCi/kg.

fp

= is the fraction of the year that animals graze on pasture. (Table 17) fs

= is the fraction of daily feed that is pasture grass while the animal grazes on pasture. (Table 17)

CH-ODCM-0001 Reference Use Page 86 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.2.3 Parameters for Calculating Radionuclide Concentration in Cow and Goat Milk

, exp Where:

CMi (r,)

= is the concentration of radionuclide (i) in milk, in pCi/liter.

CVi (r,)

= is the concentration of radionuclide (i) in the animal's feed, in pCi/kg.

Fm

= is the average fraction of the animal's daily intake of radionuclide (i) which appears in each liter of milk, in days/liter.

(Table 5)

QF

= is the amount of feed consumed by the animal per day, in kg/day. (Table 7) tf

= is the average transport time of the radionuclide (i) from the feed to the milk and to the receptor (a value of 2 days is assumed). (Table 17) i

= is the radiological decay constant of radionuclide (i), in days-1.

CH-ODCM-0001 Reference Use Page 87 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.2.4 Parameters for Calculating Radionuclide Concentration in Cow Meat, excluding Tritium

, exp Where:

CFi (r,)

= is the concentration of radionuclide (i) in meat, in pCi/liter.

CVi (r,)

= is the concentration of radionuclide (i) in the animal's feed, in pCi/kg.

QF

= is the amount of feed consumed by the animal per day, in kg/day. (Table 7)

Ff

= is the average fraction of the animal's daily intake of radionuclide (i) which appears in each kilogram of flesh, in days/kilogram. (Table 5) ts

= is the average time from slaughter to consumption. (Table 17) 3.2.5 Parameters for Calculating Tritium Concentrations in Vegetation The concentration of tritium in vegetation is calculated from its concentration in the air surrounding the vegetation.

, 3.17 10

, 0.750.5

1.2 10

Where:

CVT(r, )

= is the concentration of tritium in vegetation grown at distance r, in the sector at angle, in pCi/kg.

H

= is the absolute humidity of the atmosphere at distance r, in the sector at angle, in g/m3. H=8 gm/kg.

QT

= is the annual release rate of tritium, in Ci/yr.

[/Q](r,) = is the atmospheric dispersion factor, in sec/m3. (Table 4) 0.5

= is the ratio of tritium concentration in facility water to tritium concentration in atmospheric water, dimensionless.

0.75

= is the fraction of total facility mass that is water, dimensionless.

CH-ODCM-0001 Reference Use Page 88 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 3.2.6 Annual Dose from Atmospherically Released Radionuclides in Foods A. The total annual dose to organ (j) of an individual in age group (a) resulting from ingestion of all radionuclides in produce, milk, and leafy vegetables is given by:

Where:

DDja(r,)

= is the annual dose to organ (j) of an individual in age group (a) from dietary intake of atmospherically released radionuclides, in mrem/yr.

DFIija

= is the dose conversion factor for the ingestion of radionuclide (i), organ (j), and age group (a), in mrem/pCi. Tables 13-16.

UVa

= are the ingestion rates of produce (non-leafy vegetables, fruits, and grains), respectively for individuals in age group (a).

(Table 6)

UMa

= is the ingestion rate of cow milk for individuals in age group (a), in /yr. (Table 6)

UFa

= is the ingestion rate of meat for individuals in age group (a), in kg/yr. (Table 6)

ULa

= are the ingestion rates of leafy vegetables for individuals in age group (a), in kg/yr. (Table 6)

CVi (r,)

= is the concentration of radionuclide (i) in the animal's feed, in pCi/kg.

CMi (r,)

= is the concentration of radionuclide (i) in milk, in pCi/liter.

CFi (r,)

= is the concentration of radionuclide (i) in meat, in pCi/liter.

CLI (r,)

= is the concentration of radionuclide (i) in and on leafy vegetation, in pCi/kg.

fg

= Fraction of ingested produce grown in garden of interest (Table 17) f

= Fraction of leafy vegetables grown in garden of interest (Table 17)

CH-ODCM-0001 Reference Use Page 89 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

B. Calculating the Ingested Dose from Leafy and Non-Leafy (produce)

Vegetation for Radionuclide (i) to Each Organ (j) and Age Group (a)

Where:

DDja(r,)

= is the annual dose from the ingestion of radionuclide (i) to organ (j) of an individual in age group (a) from dietary intake of atmospherically released radionuclides in vegetation, in mrem/yr.

DFIija

= is the dose conversion factor for the ingestion of radionuclide (i), organ (j), and age group (a), in mrem/pci. Tables 13-16 ULa,UVa

= are the ingestion rates of leafy vegetables and produce (non-leafy vegetables, fruits, and grains), for individuals in age group (a), in kg/yr. (Table 6)

CLi

= is the concentration of radionuclide (i) in and on leafy vegetation, in pCi/kg.

CVi

= is the concentration of radionuclide (i) in and on produce, in pCi/kg.

fg

= Fraction of ingested produce grown in garden of interest (Table 17) f

= Fraction of leafy vegetables grown in garden of interest (Table 17)

CH-ODCM-0001 Reference Use Page 90 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

C. Calculation Determining the Ingested Dose from Cow Milk for Radionuclide (i), Organ (j), and Age Group (a)

Where:

DDja(r,)

= is the annual dose from the ingestion of radionuclide (i), organ (j) of an individual in age group (a) from dietary intake of atmospherically released radionuclides in cow milk, in mrem/yr.

DFIija

= is the dose conversion factor for the ingestion of radionuclide (i), organ (j), and age group (a), in mrem/pCi. (Tables 13-16)

UMa

= is the ingestion rate of cow milk for individuals in age group (a), in /yr. (Table 6)

CMi

= is the radionuclide concentration in cow milk, in pCi/kg.

Equation 3.2.4 D. Calculation Determining the Ingested Dose from Meat for Radionuclide (i) to Organ (j) and Age Group (a)

Where:

DDja(r,)

= is the annual dose from the ingestion of radionuclide (i), organ (j) of an individual in age group (a) from dietary intake of atmospherically released radionuclides in meat, in mrem/yr.

DFIija

= is the dose conversion factor for the ingestion of radionuclide (i), organ (j), and age group (a), in mrem/pCi. (Tables 13-16)

UFa

= is the ingestion rate of meat for individuals in age group (a), in kg/yr. (Table 6)

CFi

= is the radionuclide (i) concentration in meat, in pCi/kg.

CH-ODCM-0001 Reference Use Page 91 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP) 4.0 LOWER LIMIT OF DETECTION (LLD) 4.1 The lower limit of detection (LLD) for liquid and airborne effluent discharges and environmental samples referenced in Part I, Tables 4.1, 4.2 and 5.3, of the Off-Site Dose Calculation Manual, is defined as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will be detected with 95 percent probability with only 5 percent probability of falsely concluding that a blank observation represents a "real" signal.

4.2 For a particular measurement system, which may include radiochemical separation:

4.66 exp Where:

LLD

= the lower limit of detection as defined above, in either picoCuries or microCuries, per unit mass or volume as a function of the value of D Sb

= the standard deviation of the background counting rate or of the counting rate of a blank sample, as appropriate, as counts per minute E

= the counting efficiency, as counts per disintegration V

= the sample size in units of mass or volume D

= 2.22E+06 of disintegrations per minute per microCurie or 2.22 disintegrations per minute per picoCurie Y

= the fractional radiochemical yield, when applicable

= the radioactive decay constant for the particular radionuclide t

= the elapsed time between the midpoint of sample collection and time of counting Appropriate values of E, V, Y, and t should be used in the calculation.

4.3 It should be recognized that the LLD is defined as an A Priori limit representing the capability of a measurement system and not as a limit for a particular measurement.

4.4 LLD verifications will be performed on a periodic basis. This determination is to ensure that the counting system is able to detect levels of radiation at the LLD values for the specific type of analysis required. They will be performed with a blank (non-radioactive) sample in the same counting geometry as the actual sample.

CH-ODCM-0001 Reference Use Page 92 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 2 - Deleted Table 3 - Bioaccumulation Factors (pCi/kg per pCi/liter)

FRESHWATER Element Fish Invertebrate H

9.0E-01 9.0E-01 C

4.6E+03 9.1E+03 Na 1.0E+02 2.0E+02 P

1.0E+05 2.0E+04 Cr 2.0E+02 2.0E+03 Mn 4.0E+02 9.0E+04 Fe 1.0E+02 3.2E+03 Co 5.0E+01 2.0E+02 Ni 1.0E+02 1.0E+02 Cu 5.0E+01 4.0E+02 Zn 2.0E+03 1.0E+04 Br 4.2E+02 3.3E+02 Rb 2.0E+03 1.0E+03 Sr 3.0E+01 1.0E+02 Y

2.5E+01 1.0E+03 Zr 3.3E+00 6.7E+00 Nb 3.0E+04 1.0E+02 Mo 1.0E+01 1.0E+01 Tc 1.5E+01 5.0E+00 Ru 1.0E+01 3.0E+02 Rh 1.0E+01 3.0E+02 Te 4.0E+02 6.1E+03 I

1.5E+01 5.0E+00 Cs 2.0E+03 1.0E+03 Ba 4.0E+00 2.0E+02 La 2.5E+01 1.0E+03 Ce 1.0E+00 1.0E+03 Pr 2.5E+01 1.0E+03 Nd 2.5E+01 1.0E+03 W

1.2E+03 1.0E+01 Np 1.0E+01 4.0E+02

CH-ODCM-0001 Reference Use Page 93 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 4 - Highest Potential Exposure Pathways for Estimating Dose Exposure Pathway Location B Direction B Distance from Containment (miles) B

/Q A

{/Q (r,)}

(sec/m3)

D/Q A

{ (r,)}

(m-2)

Direct Exposure Site Boundary ESE 0.29 6.30E-05 N/A Inhalation Site Boundary ESE 0.29 6.30E-05 N/A Ingestion Residence NNW 0.29 N/A 2.30E-07 A.

These values are used for calculating quarterly dose estimates during the annual reporting period and are based on a 5 year historical average. Ten percent (10%) will be added to these values for dose estimates during the reporting periods. These values are periodically re-evaluated by comparing the X/Q values reported by NOAA in similar locations.

B.

The location is subject to change based on an annual evaluation and is utilized only for ingestion exposure pathway dose estimates. This location may differ from the highest ingestion exposure pathway for offsite air monitoring locations as determined by the Land Use Survey performed biennially in accordance with Part 1, Section 7.3.2, of the Off-Site Dose Calculation Manual.

CH-ODCM-0001 Reference Use Page 94 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 5 - Stable Element Transfer Data Element Biv Veg./Soil Fm (cow)

Milk (d/I)

Fm (goat)

Milk (d/I)

Ff Meat (d/kg)

H 4.8E+00 1.0E-02 1.7E-01 1.2E-02 C

5.5E+00 1.2E-02 1.0E-01 3.1E-02 Na 5.2E-02 4.0E-02 3.0E-02 P

1.1E+00 2.5E-02 2.5E-01 4.6E-02 Cr 2.5E-04 2.2E-03 2.4E-03 Mn 2.9E-02 2.5E-04 8.0E-04 Fe 6.6E-04 1.2E-03 1.3E-04 4.0E-02 Co 9.4E-03 1.0E-03 1.3E-02 Ni 1.9E-02 6.7E-03 5.3E-02 Cu 1.2E-01 1.4E-02 1.3E-02 8.0E-03 Zn 4.0E-01 3.9E-02 3.0E-02 Rb 1.3E-01 3.0E-02 3.1E-02 Sr 1.7E-02 8.0E-04 1.4E-02 6.0E-04 Y

2.6E-03 1.0E-05 4.6E-03 Zr 1.7E-04 5.0E-06 3.4E-02 Nb 9.4E-03 2.5E-03 2.8E-01 Mo 1.2E-01 7.5E-03 8.0E-03 Tc 2.5E-01 2.5E-02 4.0E-01 Ru 5.0E-02 1.0E-06 4.0E-01 Rh 1.3E+1 1.0E-02 1.5E-03 Ag 1.5E-01 5.0E-02 1.7E-02 Sb 1.1E-02 1.5E-03 4.0E-03 Te 1.3E+00 1.0E-03 7.7E-02 I

2.0E-02 6.0E-03 6.0E-02 2.9E-03 Cs 1.0E-02 1.2E-02 3.0E-01 4.0E-03 Ba 5.0E-03 4.0E-04 3.2E-03 La 2.5E-03 5.0E-06 2.0E-04 Ce 2.5E-03 1.0E-04 1.2E-03 Pr 2.5E-03 5.0E-06 4.7E-03 Nd 2.4E-03 5.0E-06 3.3E-03 W

1.8E-02 5.0E-04 1.3E-03 Pu 2.5E-04 2.0E-06 1.4E-05 Np 2.5E-03 5.0E-06 2.0E-04 Am 2.5E-04 5.0E-06 2.0E-04 Cm 2.5E-03 5.0E-06 2.0E-04

CH-ODCM-0001 Reference Use Page 95 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 6 - Recommended Values for Uap to Be Used for the Maximum Exposed Individual in Lieu of Site Specific Data Pathway Infant Child Teen Adult Fruits, vegetables, & grain (kg/yr) 520 630 520 Leafy vegetables (kg/yr) 26 42 64 Milk (/yr) 330 330 400 310 Meat & poultry (kg/yr) 41 65 110 Fish (fresh or salt)(kg/yr) 6.9 16 21 Other Seafood (kg/yr) 1.7 3.8 5

Drinking water (/yr) 330 510 510 730 Shoreline recreation (hr/yr) 14 67 12 Inhalation (m3/yr) 1400 3700 8000 8000 Table 7 - Animal Consumption Rates Animal QF Feed or Forage [Kg/day (wet weigh)]

QAW Water (/day)

Milk Cow 50 60 Beef Cattle 50 50 Goats 6

8

CH-ODCM-0001 Reference Use Page 96 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 8 - External Dose Factors for Standing on Contaminated Ground (mrem/hr per pCi/m2)

Element Total Body Skin H-3 C-14 Na-24 2.50E-08 2.90E-08 P-32 Cr-51 2.20E-10 2.60E-10 Mn-54 5.80E-09 6.80E-09 Mn-56 1.10E-08 1.30E-08 Fe-55 Fe-59 8.00E-09 9.40E-09 Co-58 7.00E-09 8.20E-09 Co-60 1.70E-08 2.00E-08 Ni-59 Ni-63 Nr-65 3.70E-09 4.30E-09 Cu-64 1.50E-09 1.70E-09 Zn-65 4.00E-09 4.60E-09 Zn-69 Br-83 6.40E-11 9.30E-11 Br-84 1.20E-08 1.40E-08 Br-85 Rb-86 6.30E-10 7.20E-10 Rb-88 3.50E-09 4.00E-09 Rb-89 1.50E-08 1.80E-08 Sr-89 5.60E-13 6.50E-13 Sr-91 7.10E-09 8.30E-09 Sr-92 9.00E-09 1.00E-08 Y-90 2.20E-12 2.60E-12 Y-91M 3.80E-09 4.40E-09 Y-91 2.40E-11 2.70E-11 Y-92 1.60E-09 1.90E-09 Y-93 5.70E-10 7.80E-10 Zr-95 5.00E-09 5.80E-09 Zr-97 5.50E-09 6.40E-09 Nb-95 5.10E-09 6.00E-09 Mo-99 1.90E-09 2.20E-09 Tc-99M 9.60E-10 1.10E-09

CH-ODCM-0001 Reference Use Page 97 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 8 - External Dose Factors for Standing on Contaminated Ground (mrem/hr per pCi/m2)

Element Total Body Skin Tc-101 2.70E-09 3.00E-09 Ru-103 3.60E-09 4.20E-09 Ru-105 4.50E-09 5.10E-09 Ru-106 1.50E-09 1.80E-09 Ag-110M 1.80E-08 2.10E-08 Sb-124 1.30E-08 1.50E-08 Sb-125 3.10E-09 3.50E-09 Te-125M 3.50E-11 4.80E-11 Te-127M 1.10E-12 1.30E-12 Te-127 1.00E-11 1.10E-11 Te-129M 7.70E-10 9.00E-10 Te-129 7.10E-10 8.40E-10 Te-131M 8.40E-09 9.90E-09 Te-131 2.20E-09 2.60E-06 Te-132 1.70E-09 2.00E-09 I-130 1.40E-08 1.70E-08 I-131 2.80E-09 3.40E-09 I-132 1.70E-08 2.00E-08 I-133 3.70E-09 4.50E-09 I-134 1.60E-08 1.90E-08 I-135 1.20E-08 1.40E-08 Cs-134 1.20E-08 1.40E-08 Cs-136 1.50E-08 1.70E-08 Cs-137 4.20E-09 4.90E-09 Cs-138 2.10E-08 2.40E-08 Ba-139 2.40E-09 2.70E-09 Ba-140 2.10E-09 2.40E-09 Ba-141 4.30E-09 4.90E-09 Ba-142 7.90E-09 9.00E-09 La-140 1.50E-08 1.70E-08 La-142 1.50E-08 1.80E-08 Ce-141 5.50E-10 6.20E-10 Ce-143 2.20E-09 2.50E-09 Ce-144 3.20E-10 3.70E-10 Pr-143 Pr-144 2.00E-10 2.30E-10

CH-ODCM-0001 Reference Use Page 98 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 8 - External Dose Factors for Standing on Contaminated Ground (mrem/hr per pCi/m2)

Element Total Body Skin Nd-147 1.00E-09 1.20E-09 W-187 3.10E-09 3.60E-09 Pu-238 1.30E-12 1.80E-11 Pu-239 7.90E-13 7.70E-12 Pu-240 1.30E-12 1.80E-11 Pu-241 4.60E-12 6.80E-12 Np-239 9.50E-10 1.10E-09 Am-241 1.80E-10 2.60E-10 Cm-242 5.50E-12 2.30E-11 Cm-243 2.30E-09 2.90E-09 Cm-244 2.90E-12 1.80E-11

CH-ODCM-0001 Reference Use Page 99 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 9 - Inhalation Dose Factors for Adult (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 8.98E-08 8.98E-08 8.98E-08 8.98E-08 8.98E-08 8.98E-08 C-14 2.27E-06 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 Na-24 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 P-32 1.65E-04 9.64E-06 6.26E-06 1.08E-05 Cr-51 1.25E-08 7.44E-09 2.85E-09 1.80E-06 4.15E-07 Mn-54 4.95E-06 7.87E-07 1.23E-06 1.75E-04 9.67E-06 Mn-56 1.55E-10 2.29E-11 1.63E-10 1.18E-06 2.53E-06 Fe-55 3.07E-06 2.12E-06 4.93E-07 9.01E-06 7.54E-07 Fe-59 1.47E-06 3.47E-06 1.32E-06 1.27E-04 2.35E-05 Co-58 1.98E-07 2.59E-07 1.16E-04 1.33E-05 Co-60 1.44E-06 1.85E-06 7.46E-04 3.56E-05 Ni-59 4.06E-06 1.46E-06 6.77E-07 8.20E-06 6.11E-07 Ni-63 5.40E-05 3.93E-06 1.81E-06 2.23E-05 1.67E-06 Ni-65 1.92E-10 2.62E-11 1.14E-11 7.00E-07 1.54E-06 Cu-64 1.83E-10 7.69E-11 5.78E-10 8.48E-07 6.12E-06 Zn-65 4.05E-06 1.29E-05 5.82E-06 8.62E-06 1.08E-04 6.68E-06 Zn-69 4.23E-12 8.14E-12 5.65E-13 5.27E-12 1.15E-07 2.04E-09 Br-83 3.01E-08 2.90E-08 Br-84 3.91E-08 2.05E-13 Br-85 1.60E-09 Rb-86 1.69E-05 7.37E-06 2.08E-06 Rb-88 4.84E-08 2.41E-08 4.18E-19 Rb-89 3.20E-08 2.12E-08 1.16E-21 Sr-89 3.80E-05 1.09E-06 1.75E-04 4.37E-05 Sr-90 3.59E-03 7.21E-05 1.20E-03 9.02E-05 Sr-91 7.74E-09 3.13E-10 4.56E-06 2.39E-05 Sr-92 8.43E-10 3.64E-11 2.06E-06 5.38E-06 Y-90 2.61E-07 7.01E-09 2.12E-05 6.32E-05 Y-91M 3.26E-11 1.27E-12 2.40E-07 1.66E-10 Y-91 5.78E-05 1.55E-06 2.13E-04 4.81E-05 Y-92 1.29E-09 3.77E-11 1.96E-06 9.19E-06 Y-93 1.18E-08 3.26E-10 6.06E-06 5.27E-05 Zr-95 1.34E-05 4.30E-06 2.91E-06 6.77E-06 2.21E-04 1.88E-05 Zr-97 1.21E-08 2.45E-09 1.13E-09 3.71E-09 9.84E-06 6.54E-05 Nb-95 1.76E-06 9.77E-07 5.26E-07 9.67E-07 6.31E-05 1.30E-05 Mo-99 1.51E-08 2.87E-09 3.64E-08 1.14E-05 3.10E-05

CH-ODCM-0001 Reference Use Page 100 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 9 - Inhalation Dose Factors for Adult (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 1.29E-13 3.64E-13 4.63E-12 5.52E-12 9.55E-08 5.20E-07 Tc-101 5.22E-15 7.52E-15 7.38E-14 1.35E-13 4.99E-08 1.36E-21 Ru-103 1.91E-07 8.23E-08 7.29E-07 6.31E-05 1.38E-05 Ru-105 9.88E-11 3.89E-11 1.27E-10 1.37E-06 6.02E-06 Ru-106 8.64E-06 1.09E-06 1.67E-05 1.17E-03 1.14E-04 Ag-110M 1.35E-06 1.25E-06 7.43E-07 2.46E-06 5.79E-04 3.78E-05 Sb-124 3.90E-06 7.36E-08 1.55E-06 9.44E-09 3.10E-04 5.08E-05 Sb-125 6.67E-06 7.44E-08 1.58E-06 6.75E-09 2.18E-04 1.26E-05 Te-125M 4.27E-07 1.98E-07 5.84E-08 1.31E-07 1.55E-06 3.92E-05 8.83E-06 Te-127M 1.58E-06 7.21E-07 1.96E-07 4.11E-07 5.72E-06 1.20E-04 1.87E-05 Te-127 1.75E-10 8.03E-11 3.87E-11 1.32E-10 6.37E-10 8.14E-07 7.17E-06 Te-129M 1.22E-06 5.84E-07 1.98E-07 4.30E-07 4.57E-06 1.45E-04 4.79E-05 Te-129 6.22E-12 2.99E-12 1.55E-12 4.87E-12 2.34E-11 2.42E-07 1.96E-08 Te-131M 8.74E-09 5.45E-09 3.63E-09 6.88E-09 3.86E-08 1.82E-05 6.95E-05 Te-131 1.39E-12 7.44E-13 4.49E-13 1.17E-12 5.46E-12 1.74E-07 2.30E-09 Te-132 3.25E-08 2.69E-08 2.02E-08 2.37E-08 1.82E-07 3.60E-05 6.37E-05 I-130 5.72E-07 1.68E-06 6.60E-07 1.42E-04 2.61E-06 9.61E-07 I-131 3.15E-06 4.47E-06 2.56E-06 1.49E-03 7.66E-06 7.85E-07 I-132 1.45E-07 4.07E-07 1.45E-07 1.43E-05 6.48E-07 5.08E-08 I-133 1.08E-06 1.85E-06 5.65E-07 2.69E-04 3.23E-06 1.11E-06 I-134 8.05E-08 2.16E-07 7.69E-08 3.73E-06 3.44E-07 1.26E-10 I-135 3.35E-07 8.73E-07 3.21E-07 5.60E-05 1.39E-06 6.56E-07 Cs-134 4.66E-05 1.06E-04 9.10E-05 3.59E-05 1.22E-05 1.30E-06 Cs-136 4.88E-06 1.83E-05 1.38E-05 1.07E-05 1.50E-06 1.46E-06 Cs-137 5.98E-05 7.76E-05 5.35E-05 2.78E-05 9.40E-06 1.05E-06 Cs-138 4.14E-08 7.76E-08 4.05E-08 6.00E-08 6.07E-09 2.33E-13 Ba-139 1.17E-10 8.32E-14 3.42E-12 7.78E-14 4.70E-07 1.12E-07 Ba-140 4.88E-06 6.13E-09 3.21E-07 2.09E-09 1.59E-04 2.73E-05 Ba-141 1.25E-11 9.41E-15 4.20E-13 8.75E-15 2.42E-07 1.45E-17 Ba-142 3.29E-12 3.38E-15 2.07E-13 2.86E-15 1.49E-07 1.96E-26 La-140 4.30E-08 2.17E-08 5.73E-09 1.70E-05 5.73E-05 La-142 8.54E-11 3.88E-11 9.65E-12 7.91E-07 2.64E-07 Ce-141 2.49E-06 1.69E-06 1.91E-07 7.83E-07 4.52E-05 1.50E-05 Ce-143 2.33E-08 1.72E-08 1.91E-09 7.60E-09 9.97E-06 2.83E-05 Ce-144 4.29E-04 1.79E-04 2.30E-05 1.06E-04 9.72E-04 1.02E-04 Pr-143 1.17E-06 4.69E-07 5.80E-08 2.70E-07 3.51E-05 2.50E-05

CH-ODCM-0001 Reference Use Page 101 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 9 - Inhalation Dose Factors for Adult (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 3.76E-12 1.56E-12 1.91E-13 8.81E-13 1.27E-07 2.69E-18 Nd-147 6.59E-07 7.62E-07 4.56E-08 4.45E-07 2.76E-05 2.16E-05 W-187 1.06E-09 8.85E-10 3.10E-10 3.63E-06 1.94E-05 Pu-238 1.43E+00 9.71E-01 6.90E-02 2.96E-01 1.82E-01 4.52E-05 Pu-239 1.66E+00 1.07E+00 7.75E-02 3.30E-01 1.72E-01 4.13E-05 Pu-240 1.65E+00 1.07E+00 7.73E-02 3.29E-01 1.72E-01 4.21E-05 Pu-241 3.42E-02 8.69E-03 1.29E-03 5.93E-03 1.52E-04 8.65E-07 Np-239 2.87E-08 2.54E-08 1.55E-09 8.75E-09 4.70E-06 1.49E-05 Am-241 1.68E+00 1.13E+00 6.71E-02 5.04E-01 6.06E-02 4.60E-05 Cm-242 2.22E-02 1.77E-02 9.84E-04 4.48E-03 3.92E-02 4.91E-05 Cm-243 1.10E+00 7.61E-01 4.61E-02 2.15E-01 6.31E-02 4.84E-05 Cm-244 8.37E-01 5.88E-01 3.51E-02 1.64E-01 6.06E-02 4.68E-05

CH-ODCM-0001 Reference Use Page 102 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 10 - Inhalation Dose Factors for Teenager (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 9.06E-08 9.06E-08 9.06E-08 9.06E-08 9.06E-08 9.06E-08 C-14 3.25E-06 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 Na-24 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 P-32 2.36E-04 1.37E-05 8.95E-06 1.16E-05 Cr-51 1.69E-08 9.37E-09 3.84E-09 2.62E-06 3.75E-07 Mn-54 6.39E-06 1.05E-06 1.59E-06 2.48E-04 8.35E-06 Mn-56 2.12E-10 3.15E-11 2.24E-10 1.90E-06 7.18E-06 Fe-55 4.18E-06 2.98E-06 6.93E-07 1.55E-05 7.99E-07 Fe-59 1.99E-06 4.62E-06 1.79E-06 1.91E-04 2.23E-05 Co-58 2.59E-07 3.47E-07 1.68E-04 1.19E-05 Co-60 1.89E-06 2.48E-06 1.09E-03 3.24E-05 Ni-59 5.44E-06 2.02E-06 9.24E-07 1.41E-05 6.48E-07 Ni-63 7.25E-05 5.43E-06 2.47E-06 3.84E-05 1.77E-06 Ni-65 2.73E-10 3.66E-11 1.59E-11 1.17E-06 4.59E-06 Cu-64 2.54E-10 1.06E-10 8.01E-10 1.39E-06 7.68E-06 Zn-65 4.82E-06 1.67E-05 7.80E-06 1.08E-05 1.55E-04 5.83E-06 Zn-69 6.04E-12 1.15E-11 8.07E-13 7.53E-12 1.98E-07 3.56E-08 Br-83 4.30E-08 Br-84 5.41E-08 Br-85 2.29E-09 Rb-86 2.38E-05 1.05E-05 2.21E-06 Rb-88 6.82E-08 3.40E-08 3.65E-15 Rb-89 4.40E-08 2.91E-08 4.22E-17 Sr-89 5.43E-05 1.56E-06 3.02E-04 4.64E-05 Sr-90 4.14E-03 8.33E-05 2.06E-03 9.56E-05 Sr-91 1.10E-08 4.39E-10 7.59E-06 3.24E-05 Sr-92 1.19E-09 5.08E-11 3.43E-06 1.49E-05 Y-90 3.73E-07 1.00E-08 3.66E-05 6.99E-05 Y-91M 4.63E-11 1.77E-12 4.00E-07 3.77E-09 Y-91 8.26E-05 2.21E-06 3.67E-04 5.11E-05 Y-92 1.84E-09 5.36E-11 3.35E-06 2.06E-05 Y-93 1.69E-08 4.65E-10 1.04E-05 7.24E-05 Zr-95 1.82E-05 5.73E-06 3.94E-06 8.42E-06 3.36E-04 1.86E-05 Zr-97 1.72E-08 3.40E-09 1.57E-09 5.15E-09 1.62E-05 7.88E-05 Nb-95 2.32E-06 1.29E-06 7.08E-07 1.25E-06 9.39E-05 1.21E-05 Mo-99 2.11E-08 4.03E-09 5.14E-08 1.92E-05 3.36E-05

CH-ODCM-0001 Reference Use Page 103 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 10 - Inhalation Dose Factors for Teenager (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 1.73E-13 4.83E-13 6.24E-12 7.20E-12 1.44E-07 7.66E-07 Tc-101 7.40E-15 1.05E-14 1.03E-13 1.90E-13 8.34E-08 1.09E-16 Ru-103 2.63E-07 1.12E-07 9.29E-07 9.79E-05 1.36E-05 Ru-105 1.40E-10 5.42E-11 1.76E-10 2.27E-06 1.13E-05 Ru-106 1.23E-05 1.55E-06 2.38E-05 2.01E-03 1.20E-04 Ag-110M 1.73E-06 1.64E-06 9.99E-07 3.13E-06 8.44E-04 3.41E-05 Sb-124 5.38E-06 9.92E-08 2.10E-06 1.22E-08 4.81E-04 4.98E-05 Sb-125 9.23E-06 1.01E-07 2.15E-06 8.80E-09 3.42E-04 1.24E-05 Te-125M 6.10E-07 2.80E-07 8.34E-08 1.75E-07 6.70E-05 9.38E-06 Te-127M 2.25E-06 1.02E-06 2.73E-07 5.48E-07 8.17E-06 2.07E-04 1.99E-05 Te-127 2.51E-10 1.14E-10 5.52E-11 1.77E-10 9.10E-10 1.40E-06 1.01E-05 Te-129M 1.74E-06 8.23E-07 2.81E-07 5.72E-07 6.49E-06 2.47E-04 5.06E-05 Te-129 8.87E-12 4.22E-12 2.20E-12 6.48E-12 3.32E-11 4.12E-07 2.02E-07 Te-131M 1.23E-08 7.51E-09 5.03E-09 9.06E-09 5.49E-08 2.97E-05 7.76E-05 Te-131 1.97E-12 1.04E-12 6.30E-13 1.55E-12 7.72E-12 2.92E-07 1.89E-09 Te-132 4.50E-08 3.63E-08 2.74E-08 3.07E-08 2.44E-07 5.61E-05 5.79E-05 I-130 7.80E-07 2.24E-06 8.96E-07 1.86E-04 3.44E-06 1.14E-06 I-131 4.43E-06 6.14E-06 3.30E-06 1.83E-03 1.05E-05 8.11E-07 I-132 1.99E-07 5.47E-07 1.97E-07 1.89E-05 8.65E-07 1.59E-07 I-133 1.52E-06 2.56E-06 7.78E-07 3.65E-04 4.49E-06 1.29E-06 I-134 1.11E-07 2.90E-07 1.05E-07 4.94E-06 4.58E-07 2.55E-09 I-135 4.62E-07 1.18E-06 4.36E-07 7.76E-05 1.86E-06 8.69E-07 Cs-134 6.28E-05 1.41E-04 6.86E-05 4.69E-05 1.83E-05 1.22E-06 Cs-136 6.44E-06 2.42E-05 1.71E-05 1.38E-05 2.22E-06 1.36E-06 Cs-137 8.38E-05 1.06E-04 3.89E-05 3.80E-05 1.51E-05 1.06E-06 Cs-138 5.82E-08 1.07E-07 5.58E-08 8.28E-08 9.84E-09 3.38E-11 Ba-139 1.67E-10 1.18E-13 4.87E-12 1.11E-13 8.08E-07 8.06E-07 Ba-140 6.84E-06 8.38E-09 4.40E-07 2.85E-09 2.54E-04 2.86E-05 Ba-141 1.78E-11 1.32E-14 5.93E-13 1.23E-14 4.11E-07 9.33E-14 Ba-142 4.62E-12 4.63E-15 2.84E-13 3.92E-15 2.39E-07 5.99E-20 La-140 5.99E-08 2.95E-08 7.82E-09 2.68E-05 6.09E-05 La-142 1.20E-10 5.31E-11 1.32E-11 1.27E-06 1.50E-06 Ce-141 3.55E-06 2.37E-06 2.71E-07 1.11E-06 7.67E-05 1.58E-05 Ce-143 3.32E-08 2.42E-08 2.70E-09 1.08E-08 1.63E-05 3.19E-05 Ce-144 6.11E-04 2.53E-04 3.28E-05 1.51E-04 1.67E-03 1.08E-04 Pr-143 1.67E-06 6.64E-07 8.28E-08 3.86E-07 6.04E-05 2.67E-05

CH-ODCM-0001 Reference Use Page 104 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 10 - Inhalation Dose Factors for Teenager (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 5.37E-12 2.20E-12 2.72E-13 1.26E-12 2.19E-07 2.94E-14 Nd-147 9.83E-07 1.07E-06 6.41E-08 6.28E-07 4.65E-05 2.28E-05 W-187 1.50E-09 1.22E-09 4.29E-10 5.92E-06 2.21E-05 Pu-238 1.50E+00 1.03E+00 7.22E-02 3.10E-01 3.12E-01 4.79E-05 Pu-239 1.73E+00 1.12E+00 8.05E-02 3.44E-01 2.93E-01 4.37E-05 Pu-240 1.72E+00 1.12E+00 8.04E-02 3.43E-01 2.93E-01 4.46E-05 Pu-241 3.74E-02 9.56E-03 1.40E-03 6.47E-03 2.60E-04 9.17E-07 Np-239 4.23E-08 3.60E-08 2.21E-09 1.25E-08 8.11E-06 1.65E-05 Am-241 1.77E+00 1.20E+00 7.10E-02 5.32E-01 1.05E-01 4.88E-05 Cm-242 3.17E-02 2.51E-02 1.41E-03 6.40E-03 6.76E-02 5.21E-05 Cm-243 1.19E+00 8.30E-01 5.00E-02 2.34E-01 1.09E-01 5.13E-05 Cm-244 9.19E-01 6.53E-01 3.88E-02 1.81E-01 1.05E-01 4.96E-05

CH-ODCM-0001 Reference Use Page 105 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 11 - Inhalation Dose Factors for Child (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 1.73E-07 1.73E-07 1.73E-07 1.73E-07 1.73E-07 1.73E-07 C-14 9.70E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 Na-24 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 P-32 7.04E-04 3.09E-05 2.67E-05 1.14E-05 Cr-51 4.17E-08 2.31E-08 6.57E-09 4.59E-06 2.93E-07 Mn-54 1.16E-05 2.57E-06 2.71E-06 4.26E-04 6.19E-06 Mn-56 4.48E-10 8.43E-11 4.52E-10 3.55E-06 3.33E-05 Fe-55 1.28E-05 6.80E-06 2.10E-06 3.00E-05 7.75E-07 Fe-59 5.59E-06 9.04E-06 4.51E-06 3.43E-04 1.91E-05 Co-58 4.79E-07 8.55E-07 2.99E-04 9.29E-06 Co-60 3.55E-06 6.12E-06 1.91E-03 2.60E-05 Ni-59 1.66E-05 4.67E-06 2.83E-06 2.73E-05 6.29E-07 Ni-63 2.22E-04 1.25E-05 7.56E-06 7.43E-05 1.71E-06 Ni-65 8.08E-10 7.99E-11 4.44E-11 2.21E-06 2.27E-05 Cu-64 5.39E-10 2.90E-10 1.63E-09 2.59E-06 9.92E-06 Zn-65 1.15E-05 3.06E-05 1.90E-05 1.93E-05 2.69E-04 4.41E-06 Zn-69 1.81E-11 2.61E-11 2.41E-12 1.58E-11 3.84E-07 2.75E-06 Br-83 1.28E-07 Br-84 1.48E-07 Br-85 6.84E-09 Rb-86 5.36E-05 3.09E-05 2.16E-06 Rb-88 1.52E-07 9.90E-08 4.66E-09 Rb-89 9.33E-08 7.85E-08 5.11E-10 Sr-89 1.62E-04 4.66E-06 5.83E-04 4.52E-05 Sr-90 1.04E-02 2.07E-04 3.99E-03 9.28E-05 Sr-91 3.28E-08 1.24E-09 1.44E-05 4.70E-05 Sr-92 3.54E-09 1.42E-10 6.49E-06 6.55E-05 Y-90 1.11E-06 2.99E-08 7.07E-05 7.24E-05 Y-91M 1.37E-10 4.98E-12 7.60E-07 4.64E-07 Y-91 2.47E-04 6.59E-06 7.10E-04 4.97E-05 Y-92 5.50E-09 1.57E-10 6.46E-06 6.46E-05 Y-93 5.04E-08 1.38E-09 2.01E-05 1.05E-04 Zr-95 5.13E-05 1.13E-05 1.00E-05 1.61E-05 6.03E-04 1.65E-05 Zr-97 5.07E-08 7.34E-09 4.32E-09 1.05E-08 3.06E-05 9.49E-05 Nb-95 6.35E-06 2.48E-06 1.77E-06 2.33E-06 1.66E-04 1.00E-05 Mo-99 4.66E-08 1.15E-08 1.06E-07 3.66E-05 3.42E-05

CH-ODCM-0001 Reference Use Page 106 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 11 - Inhalation Dose Factors for Child (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 4.81E-13 9.41E-13 1.56E-11 1.37E-11 2.57E-07 1.30E-06 Tc-101 2.19E-14 2.30E-14 2.91E-13 3.92E-13 1.58E-07 4.41E-09 Ru-103 7.55E-07 2.90E-07 1.90E-06 1.79E-04 1.21E-05 Ru-105 4.13E-10 1.50E-10 3.63E-10 4.30E-06 2.69E-05 Ru-106 3.68E-05 4.57E-06 4.97E-05 3.87E-03 1.16E-04 Ag-110M 4.56E-06 3.08E-06 2.47E-06 5.74E-06 1.48E-03 2.71E-05 Sb-124 1.55E-05 2.00E-07 5.41E-06 3.41E-08 8.76E-04 4.43E-05 Sb-125 2.66E-05 2.05E-07 5.59E-06 2.46E-08 6.27E-04 1.09E-05 Te-125M 1.82E-06 6.29E-07 2.47E-07 5.20E-07 1.29E-04 9.13E-06 Te-127M 6.72E-06 2.31E-06 8.16E-07 1.64E-06 1.72E-05 4.00E-04 1.93E-05 Te-127 7.49E-10 2.57E-10 1.65E-10 5.30E-10 1.91E-09 2.71E-06 1.52E-05 Te-129M 5.19E-06 1.85E-06 8.22E-07 1.71E-06 1.36E-05 4.76E-04 4.91E-05 Te-129 2.64E-11 9.45E-12 6.44E-12 1.93E-11 6.94E-11 7.93E-07 6.89E-06 Te-131M 3.63E-08 1.60E-08 1.37E-08 2.64E-08 1.08E-07 5.56E-05 8.32E-05 Te-131 5.87E-12 2.28E-12 1.78E-12 4.59E-12 1.59E-11 5.55E-07 3.60E-07 Te-132 1.30E-07 7.36E-08 7.12E-08 8.58E-08 4.79E-07 1.02E-04 3.72E-05 I-130 2.21E-06 4.43E-06 2.28E-06 4.99E-04 6.61E-06 1.38E-06 I-131 1.30E-05 1.30E-05 7.37E-06 4.39E-03 2.13E-05 7.68E-07 I-132 5.72E-07 1.10E-06 5.07E-07 5.23E-05 1.69E-06 8.65E-07 I-133 4.48E-06 5.49E-06 2.08E-06 1.04E-03 9.13E-06 1.48E-06 I-134 3.17E-07 5.84E-07 2.69E-07 1.37E-05 8.92E-07 2.58E-07 I-135 1.33E-06 2.36E-06 1.12E-06 2.14E-04 3.62E-06 1.20E-06 Cs-134 1.76E-04 2.74E-04 6.07E-05 8.93E-05 3.27E-05 1.04E-06 Cs-136 1.76E-05 4.62E-05 3.14E-05 2.58E-05 3.93E-06 1.13E-06 Cs-137 2.45E-04 2.23E-04 3.47E-05 7.63E-05 2.81E-05 9.78E-07 Cs-138 1.71E-07 2.27E-07 1.50E-07 1.68E-07 1.84E-08 7.29E-08 Ba-139 4.98E-10 2.66E-13 1.45E-11 2.33E-13 1.56E-06 1.56E-05 Ba-140 2.00E-05 1.75E-08 1.17E-06 5.71E-09 4.71E-04 2.75E-05 Ba-141 5.29E-11 2.95E-14 1.72E-12 2.56E-14 7.89E-07 7.44E-08 Ba-142 1.35E-11 9.73E-15 7.54E-13 7.87E-15 4.44E-07 7.41E-10 La-140 1.74E-07 6.08E-08 2.04E-08 4.94E-05 6.10E-05 La-142 3.50E-10 1.11E-10 3.49E-11 2.35E-06 2.05E-05 Ce-141 1.06E-05 5.28E-06 7.83E-07 2.31E-06 1.47E-04 1.53E-05 Ce-143 9.89E-08 5.37E-08 7.77E-09 2.26E-08 3.12E-05 3.44E-05 Ce-144 1.83E-03 5.72E-04 9.77E-05 3.17E-04 3.23E-03 1.05E-04 Pr-143 4.99E-06 1.50E-06 2.47E-07 8.11E-07 1.17E-04 2.63E-05

CH-ODCM-0001 Reference Use Page 107 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 11 - Inhalation Dose Factors for Child (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 1.61E-11 4.99E-12 8.10E-13 2.64E-12 4.23E-07 5.32E-08 Nd-147 2.92E-06 2.36E-06 1.84E-07 1.30E-06 8.87E-05 2.22E-05 W-187 4.41E-09 2.61E-09 1.17E-09 1.11E-05 2.46E-05 Pu-238 2.55E+00 1.60E+00 1.21E-01 4.47E-01 6.08E-01 4.65E-05 Pu-239 2.79E+00 1.68E+00 1.28E-01 4.78E-01 5.72E-01 4.24E-05 Pu-240 2.79E+00 1.68E+00 1.27E-01 4.77E-01 5.71E-01 4.33E-05 Pu-241 7.94E-02 1.75E-02 2.93E-03 1.10E-02 5.06E-04 8.90E-07 Np-239 1.26E-07 8.14E-08 6.35E-09 2.63E-08 1.57E-05 1.73E-05 Am-241 2.97E+00 1.84E+00 1.24E-01 7.63E-01 2.02E-01 4.73E-05 Cm-242 9.48E-02 5.68E-02 4.20E-03 1.34E-02 1.31E-01 5.06E-05 Cm-243 2.32E+00 1.42E+00 9.95E-02 3.74E-01 2.10E-01 4.98E-05 Cm-244 1.94E+00 1.18E+00 8.31E-02 3.06E-01 2.02E-01 4.82E-05

CH-ODCM-0001 Reference Use Page 108 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 12 - Inhalation Dose Factors for Infant (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 2.63E-07 2.63E-07 2.63E-07 2.63E-07 2.63E-07 2.63E-07 C-14 1.89E-05 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 Na-24 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 P-32 1.45E-03 8.03E-05 5.53E-05 1.15E-05 Cr-51 6.39E-08 4.11E-08 9.45E-09 9.17E-06 2.55E-07 Mn-54 1.81E-05 3.56E-06 3.56E-06 7.14E-04 5.04E-06 Mn-56 1.10E-09 1.58E-10 7.86E-10 8.95E-06 5.12E-05 Fe-55 1.41E-05 8.39E-06 2.38E-06 6.21E-05 7.82E-07 Fe-59 9.69E-06 1.68E-05 6.77E-06 7.25E-04 1.77E-05 Co-58 8.71E-07 1.30E-06 5.55E-04 7.95E-06 Co-60 5.73E-06 8.41E-06 3.22E-03 2.28E-05 Ni-59 1.81E-05 5.44E-06 3.10E-06 5.48E-05 6.34E-07 Ni-63 2.42E-04 1.46E-05 8.29E-06 1.49E-04 1.73E-06 Ni-65 1.71E-09 2.03E-10 8.79E-11 5.80E-06 3.58E-05 Cu-64 1.34E-09 5.53E-10 2.84E-09 6.64E-06 1.07E-05 Zn-65 1.38E-05 4.47E-05 2.22E-05 2.32E-05 4.62E-04 3.67E-05 Zn-69 3.85E-11 6.91E-11 5.13E-12 2.87E-11 1.05E-06 9.44E-06 Br-83 2.72E-07 Br-84 2.86E-07 Br-85 1.46E-08 Rb-86 1.36E-04 6.30E-05 2.17E-06 Rb-88 3.98E-07 2.05E-07 2.42E-07 Rb-89 2.29E-07 1.47E-07 4.87E-08 Sr-89 2.84E-04 8.15E-06 1.45E-03 4.57E-05 Sr-90 1.11E-02 2.23E-04 8.03E-03 9.36E-05 Sr-91 6.83E-08 2.47E-09 3.76E-05 5.24E-05 Sr-92 7.50E-09 2.79E-10 1.70E-05 1.00E-04 Y-90 2.35E-06 6.30E-08 1.92E-04 7.43E-05 Y-91M 2.91E-10 9.90E-12 1.99E-06 1.68E-06 Y-91 4.20E-04 1.12E-05 1.75E-03 5.02E-05 Y-92 1.17E-08 3.29E-10 1.75E-05 9.04E-05 Y-93 1.07E-07 2.91E-09 5.46E-05 1.19E-04 Zr-95 8.24E-05 1.99E-05 1.45E-05 2.22E-05 1.25E-03 1.55E-05 Zr-97 1.07E-07 1.83E-08 8.36E-09 1.85E-08 7.88E-05 1.00E-04 Nb-95 1.12E-05 4.59E-06 2.70E-06 3.37E-06 3.42E-04 9.05E-06 Mo-99 1.18E-07 2.31E-08 1.89E-07 9.63E-05 3.48E-05

CH-ODCM-0001 Reference Use Page 109 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 12 - Inhalation Dose Factors for Infant (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 9.98E-13 2.06E-12 2.66E-11 2.22E-11 5.79E-07 1.45E-06 Tc-101 4.65E-14 5.88E-14 5.80E-13 6.99E-13 4.17E-07 6.03E-07 Ru-103 1.44E-06 4.85E-07 3.03E-06 3.94E-04 1.15E-05 Ru-105 8.74E-10 2.93E-10 6.42E-10 1.12E-05 3.46E-05 Ru-106 6.20E-05 7.77E-06 7.61E-05 8.26E-03 1.17E-04 Ag-110M 7.13E-06 5.16E-06 3.57E-06 7.80E-06 2.62E-03 2.36E-05 Sb-124 2.71E-05 3.97E-07 8.56E-06 7.18E-08 1.89E-03 4.22E-05 Sb-125 3.69E-05 3.41E-07 7.78E-06 4.45E-08 1.17E-03 1.05E-05 Te-125M 3.40E-06 1.42E-06 4.70E-07 1.16E-06 3.19E-04 9.22E-06 Te-127M 1.19E-05 4.93E-06 1.48E-06 3.48E-06 2.68E-05 9.37E-04 1.95E-05 Te-127 1.59E-09 6.81E-10 3.40E-10 1.32E-09 3.47E-09 7.39E-06 1.74E-05 Te-129M 1.01E-05 4.35E-06 1.59E-06 3.91E-06 2.27E-05 1.20E-03 4.93E-05 Te-129 5.63E-11 2.48E-11 1.34E-11 4.82E-11 1.25E-10 2.14E-06 1.88E-05 Te-131M 7.62E-08 3.93E-08 2.59E-08 6.38E-08 1.89E-07 1.42E-04 8.51E-05 Te-131 1.24E-11 5.87E-12 3.57E-12 1.13E-11 2.85E-11 1.47E-06 5.87E-06 Te-132 2.66E-07 1.69E-07 1.26E-07 1.99E-07 7.39E-07 2.43E-04 3.15E-05 I-130 4.54E-06 9.91E-06 3.98E-06 1.14E-03 1.09E-05 1.42E-06 I-131 2.71E-05 3.17E-05 1.40E-05 1.06E-02 3.70E-05 7.56E-07 I-132 1.21E-06 2.53E-06 8.99E-07 1.21E-04 2.82E-06 1.36E-06 I-133 9.46E-06 1.37E-05 4.00E-06 2.54E-03 1.60E-05 1.54E-06 I-134 6.58E-07 1.34E-06 4.75E-07 3.18E-05 1.49E-06 9.21E-07 I-135 2.76E-06 5.43E-06 1.98E-06 4.97E-04 6.05E-06 1.31E-06 Cs-134 2.83E-04 5.02E-04 5.32E-05 1.36E-04 5.69E-05 9.53E-07 Cs-136 3.45E-05 9.61E-05 3.78E-05 4.03E-05 8.40E-06 1.02E-06 Cs-137 3.92E-04 4.37E-04 3.25E-05 1.23E-04 5.09E-05 9.53E-07 Cs-138 3.61E-07 5.58E-07 2.84E-07 2.93E-07 4.67E-08 6.26E-07 Ba-139 1.06E-09 7.03E-13 3.07E-11 4.23E-13 4.25E-06 3.64E-05 Ba-140 4.00E-05 4.00E-08 2.07E-06 9.59E-09 1.14E-03 2.74E-05 Ba-141 1.12E-10 7.70E-14 3.55E-12 4.64E-14 2.12E-06 3.39E-06 Ba-142 2.84E-11 2.36E-14 1.40E-12 1.36E-14 1.11E-06 4.95E-07 La-140 3.61E-07 1.43E-07 3.68E-08 1.20E-04 6.06E-05 La-142 7.36E-10 2.69E-10 6.46E-11 5.87E-06 4.25E-05 Ce-141 1.98E-05 1.19E-05 1.42E-06 3.75E-06 3.69E-04 1.54E-05 Ce-143 2.09E-07 1.38E-07 1.58E-08 4.03E-08 8.30E-05 3.55E-05 Ce-144 2.28E-03 8.65E-04 1.26E-04 3.84E-04 7.03E-03 1.06E-04 Pr-143 1.00E-05 3.74E-06 4.99E-07 1.41E-06 3.09E-04 2.66E-05

CH-ODCM-0001 Reference Use Page 110 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 12 - Inhalation Dose Factors for Infant (mrem per pCi Inhaled)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 3.42E-11 1.32E-11 1.72E-12 4.80E-12 1.15E-06 3.06E-06 Nd-147 5.67E-06 5.81E-06 3.57E-07 2.25E-06 2.30E-04 2.23E-05 W-187 9.26E-09 6.44E-09 2.23E-09 2.83E-05 2.54E-05 Pu-238 2.69E+00 1.68E+00 1.27E-01 4.64E-01 9.03E-01 4.69E-05 Pu-239 2.93E+00 1.76E+00 1.34E-01 4.95E-01 8.47E-01 4.28E-05 Pu-240 2.93E+00 1.75E+00 1.34E-01 4.94E-01 8.47E-01 4.36E-05 Pu-241 8.43E-02 1.85E-02 3.11E-03 1.15E-02 7.62E-04 8.97E-07 Np-239 2.65E-07 2.13E-07 1.34E-08 4.73E-08 4.25E-05 1.78E-05 Am-241 3.15E+00 1.95E+00 1.31E-01 7.94E-01 4.06E-01 4.78E-05 Cm-242 1.28E-01 8.65E-02 5.70E-03 1.69E-02 2.97E-01 5.10E-05 Cm-243 2.47E+00 1.52E+00 1.06E-01 3.91E-01 4.24E-01 5.02E-05 CM-244 2.07E+00 1.27E+00 8.89E-02 3.21E-01 4.08E-01 4.86E-05

CH-ODCM-0001 Reference Use Page 111 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 13 - Ingestion Dose Factors for Adult (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 5.99E-08 5.99E-08 5.99E-08 5.99E-08 5.99E-08 5.99E-08 C-14 2.84E-06 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 Na-24 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 P-32 1.93E-04 1.20E-05 7.46E-06 2.17E-05 Cr-51 2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07 Mn-54 4.57E-06 8.72E-07 1.36E-06 1.40E-05 Mn-56 1.15E-07 2.04E-08 1.46E-07 3.67E-06 Fe-55 2.75E-06 1.90E-06 4.43E-07 1.06E-06 1.09E-06 Fe-59 4.34E-06 1.02E-05 3.91E-06 2.85E-06 3.40E-05 Co-58 7.45E-07 1.67E-06 1.51E-05 Co-60 2.14E-06 4.72E-06 4.02E-05 Ni-59 9.76E-06 3.35E-06 1.63E-06 6.90E-07 Ni-63 1.30E-04 9.01E-06 4.36E-06 1.88E-06 Ni-65 5.28E-07 6.86E-08 3.13E-08 1.74E-06 Cu-64 8.33E-08 3.91E-08 2.10E-07 7.10E-06 Zn-65 4.84E-06 1.54E-05 6.96E-06 1.03E-05 9.70E-06 Zn-69 1.03E-08 1.97E-08 1.37E-09 1.28E-08 2.96E-09 Br-83 4.02E-08 5.79E-08 Br-84 5.21E-08 4.09E-13 Br-85 2.14E-09 Rb-86 2.11E-05 9.83E-06 4.16E-06 Rb-88 6.05E-08 3.21E-08 8.36E-19 Rb-89 4.01E-08 2.82E-08 2.33E-21 Sr-89 3.08E-04 8.84E-06 4.94E-05 Sr-90 8.71E-03 1.75E-04 2.19E-04 Sr-91 5.67E-06 2.29E-07 2.70E-05 Sr-92 2.15E-06 9.30E-08 4.26E-05 Y-90 9.62E-09 2.58E-10 1.02E-04 Y-91M 9.09E-11 3.52E-12 2.67E-10 Y-91 1.41E-07 3.77E-09 7.76E-05 Y-92 8.45E-10 2.47E-11 1.48E-05 Y-93 2.68E-09 7.40E-11 8.50E-05 Zr-95 3.04E-08 9.75E-09 6.60E-09 1.53E-08 3.09E-05 Zr-97 1.68E-09 3.39E-10 1.55E-10 5.12E-10 1.05E-04 Nb-95 6.22E-09 3.46E-09 1.86E-09 3.42E-09 2.10E-05 Mo-99 4.31E-06 8.20E-07 9.76E-06 9.99E-06

CH-ODCM-0001 Reference Use Page 112 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 13 - Ingestion Dose Factors for Adult (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 2.47E-10 6.98E-10 8.89E-09 1.06E-08 3.42E-10 4.13E-07 Tc-101 2.54E-10 3.66E-10 3.59E-09 6.59E-09 1.87E-10 1.10E-21 Ru-103 1.85E-07 7.97E-08 7.06E-07 2.16E-05 Ru-105 1.54E-08 6.08E-09 1.99E-07 9.42E-06 Ru-106 2.75E-06 3.48E-07 5.31E-06 1.78E-04 Ag-110M 1.60E-07 1.48E-07 8.79E-08 2.91E-07 6.04E-05 Sb-124 2.80E-06 5.29E-08 1.11E-06 6.79E-09 2.18E-06 7.95E-05 Sb-125 1.79E-06 2.00E-08 4.26E-07 1.82E-09 1.38E-06 1.97E-05 Te-125M 2.68E-06 9.71E-07 3.59E-07 8.06E-07 1.09E-05 1.07E-05 Te-127M 6.77E-06 2.42E-06 8.25E-07 1.73E-06 2.75E-05 2.27E-05 Te-127 1.10E-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 8.68E-06 Te-129M 1.15E-05 4.29E-06 1.82E-06 3.95E-06 4.80E-05 5.79E-05 Te-129 3.14E-08 1.18E-08 7.65E-09 2.41E-08 1.32E-07 2.37E-08 Te-131M 1.73E-06 8.46E-07 7.05E-07 1.34E-06 8.57E-06 8.40E-05 Te-131 1.97E-08 8.23E-09 6.22E-09 1.62E-08 8.63E-08 2.79E-09 Te-132 2.52E-06 1.63E-06 1.53E-06 1.80E-06 1.57E-05 7.71E-05 I-130 7.56E-07 2.23E-06 8.80E-07 1.89E-04 3.48E-06 1.92E-06 I-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 1.57E-06 I-132 2.03E-07 5.43E-07 1.90E-07 1.90E-05 8.65E-07 1.02E-07 I-133 1.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 2.22E-06 I-134 1.06E-07 2.88E-07 1.03E-07 4.99E-06 4.58E-07 2.51E-10 I-135 4.43E-07 1.16E-06 4.28E-07 7.65E-05 1.86E-06 1.31E-06 Cs-134 6.22E-05 1.48E-04 1.21E-04 4.79E-05 1.59E-05 2.59E-06 Cs-136 6.51E-06 2.57E-05 1.85E-05 1.43E-05 1.96E-06 2.92E-06 Cs-137 7.97E-05 1.09E-04 7.14E-05 3.70E-05 1.23E-05 2.11E-06 Cs-138 5.52E-08 1.09E-07 5.40E-08 8.01E-08 7.91E-09 4.65E-13 Ba-139 9.70E-08 6.91E-11 2.84E-09 6.46E-11 3.92E-11 1.72E-07 Ba-140 2.03E-05 2.55E-08 1.33E-06 8.67E-09 1.46E-08 4.18E-05 Ba-141 4.71E-08 3.56E-11 1.59E-09 3.31E-11 2.02E-11 2.22E-17 Ba-142 2.13E-08 2.19E-11 1.34E-09 1.85E-11 1.24E-11 3.00E-26 La-140 2.50E-09 1.26E-09 3.33E-10 9.25E-05 La-142 1.28E-10 5.82E-11 1.45E-11 4.25E-07 Ce-141 9.36E-09 6.33E-09 7.18E-10 2.94E-09 2.42E-05 Ce-143 1.65E-09 1.22E-06 1.35E-10 5.37E-10 4.56E-05 Ce-144 4.88E-07 2.04E-07 2.62E-08 1.21E-07 1.65E-04 Pr-143 9.20E-09 3.69E-09 4.56E-10 2.13E-09 4.03E-05

CH-ODCM-0001 Reference Use Page 113 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 13 - Ingestion Dose Factors for Adult (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 3.01E-11 1.25E-11 1.53E-12 7.05E-12 4.33E-18 Nd-147 6.29E-09 7.27E-09 4.35E-10 4.25E-09 3.49E-05 W-187 1.03E-07 8.61E-08 3.01E-08 2.82E-05 Pu-238 6.30E-04 7.98E-05 1.71E-05 7.32E-05 7.30E-05 Pu-239 7.25E-04 8.71E-05 1.91E-05 8.11E-05 6.66E-05 Pu-240 7.24E-04 8.70E-05 1.91E-05 8.10E-05 6.78E-05 Pu-241 1.57E-05 7.45E-07 3.32E-07 1.53E-06 1.40E-06 Np-239 1.19E-09 1.17E-10 6.45E-11 3.65E-10 2.40E-05 Am-241 7.55E-04 7.05E-04 5.41E-05 4.07E-04 7.42E-05 Cm-242 2.06E-05 2.19E-05 1.37E-06 6.22E-06 7.92E-05 Cm-243 5.99E-04 5.49E-04 3.75E-05 1.75E-04 7.81E-05 Cm-244 4.56E-04 4.27E-04 2.87E-05 1.34E-04 7.55E-05

CH-ODCM-0001 Reference Use Page 114 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 14 - Ingestion Dose Factors for Teenager (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 6.04E-08 6.04E-08 6.04E-08 6.04E-08 6.04E-08 6.04E-08 C-14 4.06E-06 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 Na-24 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 P-32 2.76E-04 1.71E-05 1.07E-05 2.32E-05 Cr-51 3.60E-09 2.00E-09 7.89E-10 5.14E-09 6.05E-07 Mn-54 5.90E-06 1.17E-06 1.76E-06 1.21E-05 Mn-56 1.58E-07 2.81E-08 2.00E-07 1.04E-05 Fe-55 3.78E-06 2.68E-06 6.25E-07 1.70E-06 1.16E-06 Fe-59 5.87E-06 1.37E-05 5.29E-06 4.32E-06 3.24E-05 Co-58 9.72E-07 2.24E-06 1.34E-05 Co-60 2.81E-06 6.33E-06 3.66E-05 Ni-59 1.32E-05 4.66E-06 2.24E-06 7.31E-07 Ni-63 1.77E-04 1.25E-05 6.00E-06 1.99E-06 Ni-65 7.49E-07 9.57E-08 4.36E-08 5.19E-06 Cu-64 1.15E-07 5.41E-08 2.91E-07 8.92E-06 Zn-65 5.76E-06 2.00E-05 9.33E-06 1.28E-05 8.47E-06 Zn-69 1.47E-08 2.80E-08 1.96E-09 1.83E-08 5.16E-08 Br-83 5.74E-08 Br-84 7.22E-08 Br-85 3.05E-09 Rb-86 2.98E-05 1.40E-05 4.41E-06 Rb-88 8.52E-08 4.54E-08 7.30E-15 Rb-89 5.50E-08 3.89E-08 8.43E-17 Sr-89 4.40E-04 1.26E-05 5.24E-05 Sr-90 1.02E-02 2.04E-04 2.33E-04 Sr-91 8.07E-06 3.21E-07 3.66E-05 Sr-92 3.05E-06 1.30E-07 7.77E-05 Y-90 1.37E-08 3.69E-10 1.13E-04 Y-91M 1.29E-10 4.93E-12 6.09E-09 Y-91 2.01E-07 5.39E-09 8.24E-05 Y-92 1.21E-09 3.50E-11 3.32E-05 Y-93 3.83E-09 1.05E-10 1.17E-04 Zr-95 4.12E-08 1.30E-08 8.94E-09 1.91E-08 3.00E-05 Zr-97 2.37E-09 4.69E-10 2.16E-10 7.11E-10 1.27E-04 Nb-95 8.22E-09 4.56E-09 2.51E-09 4.42E-09 1.95E-05 Mo-99 6.03E-06 1.15E-06 1.38E-05 1.08E-05

CH-ODCM-0001 Reference Use Page 115 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 14 - Ingestion Dose Factors for Teenager (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 3.32E-10 9.26E-10 1.20E-08 1.38E-08 5.14E-10 6.08E-07 Tc-101 3.60E-10 5.12E-10 5.03E-09 9.26E-09 3.12E-10 8.75E-17 Ru-103 2.55E-07 1.09E-07 8.99E-07 2.13E-05 Ru-105 2.18E-08 8.46E-09 2.75E-07 1.76E-05 Ru-106 3.92E-06 4.94E-07 7.56E-06 1.88E-04 Ag-110M 2.05E-07 1.94E-07 1.18E-07 3.70E-07 5.45E-05 Sb-124 3.87E-06 7.13E-08 1.51E-06 8.78E-09 3.38E-06 7.80E-05 Sb-125 2.48E-06 2.71E-08 5.80E-07 2.37E-09 2.18E-06 1.93E-05 Te-125M 3.83E-06 1.38E-06 5.12E-07 1.07E-06 1.13E-05 Te-127M 9.67E-06 3.43E-06 1.15E-06 2.30E-06 3.92E-05 2.41E-05 Te-127 1.58E-07 5.60E-08 3.40E-08 1.09E-07 6.40E-07 1.22E-05 Te-129M 1.63E-05 6.05E-06 2.58E-06 5.26E-06 6.82E-05 6.12E-05 Te-129 4.48E-08 1.67E-08 1.09E-08 3.20E-08 1.88E-07 2.45E-07 Te-131M 2.44E-06 1.17E-06 9.76E-07 1.76E-06 1.22E-05 9.39E-05 Te-131 2.79E-08 1.15E-08 8.72E-09 2.15E-08 1.22E-07 2.29E-09 Te-132 3.49E-06 2.21E-06 2.08E-06 2.33E-06 2.12E-05 7.00E-05 I-130 1.03E-06 2.98E-06 1.19E-06 2.43E-04 4.59E-06 2.29E-06 I-131 5.85E-06 8.19E-06 4.40E-06 2.39E-03 1.41E-05 1.62E-06 I-132 2.79E-07 7.30E-07 2.62E-07 2.46E-05 1.15E-06 3.18E-07 I-133 2.01E-06 3.41E-06 1.04E-06 4.76E-04 5.98E-06 2.58E-06 I-134 1.46E-07 3.87E-07 1.39E-07 6.45E-06 6.10E-07 5.10E-09 I-135 6.10E-07 1.57E-06 5.82E-07 1.01E-04 2.48E-06 1.74E-06 Cs-134 8.37E-05 1.97E-04 9.14E-05 6.26E-05 2.39E-05 2.45E-06 Cs-136 8.59E-06 3.38E-05 2.27E-05 1.84E-05 2.90E-06 2.72E-06 Cs-137 1.12E-04 1.49E-04 5.19E-05 5.07E-05 1.97E-05 2.12E-06 Cs-138 7.76E-08 1.49E-07 7.45E-08 1.10E-07 1.28E-08 4.76E-11 Ba-139 1.39E-07 9.78E-11 4.05E-09 9.22E-11 6.74E-11 1.24E-06 Ba-140 2.84E-05 3.48E-08 1.83E-06 1.18E-08 2.34E-08 4.38E-05 Ba-141 6.71E-08 5.01E-11 2.24E-09 4.65E-11 3.43E-11 1.43E-13 Ba-142 2.99E-08 2.99E-11 1.84E-09 2.53E-11 1.99E-11 9.18E-20 La-140 3.48E-09 1.71E-09 4.55E-10 9.28E-05 La-142 1.79E-10 7.95E-11 1.98E-11 2.42E-06 Ce-141 1.33E-08 8.88E-09 1.02E-09 4.18E-09 2.54E-05 Ce-143 2.35E-09 1.71E-06 1.91E-10 7.67E-10 5.14E-05 Ce-144 6.96E-07 2.88E-07 3.74E-08 1.72E-07 1.75E-04 Pr-143 1.31E-08 5.23E-09 6.52E-10 3.04E-09 4.31E-05

CH-ODCM-0001 Reference Use Page 116 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 14 - Ingestion Dose Factors for Teenager (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 4.30E-11 1.76E-11 2.18E-12 1.01E-11 4.74E-14 Nd-147 9.38E-09 1.02E-08 6.11E-10 5.99E-09 3.68E-05 W-187 1.46E-07 1.19E-07 4.17E-08 3.22E-05 Pu-238 6.70E-04 8.58E-05 1.82E-05 7.80E-05 7.73E-05 Pu-239 7.65E-04 9.29E-05 2.01E-05 8.57E-05 7.06E-05 Pu-240 7.64E-04 9.27E-05 2.01E-05 8.56E-05 7.19E-05 Pu-241 1.75E-05 8.40E-07 3.69E-07 1.71E-06 1.48E-06 Np-239 1.76E-09 1.66E-10 9.22E-11 5.21E-10 2.67E-05 Am-241 7.98E-04 7.53E-04 5.75E-05 4.31E-04 7.87E-05 Cm-242 2.94E-05 3.10E-05 1.95E-06 8.89E-06 8.40E-05 Cm-243 6.50E-04 6.03E-04 4.09E-05 1.91E-04 8.28E-05 Cm-244 5.04E-04 4.77E-04 3.19E-05 1.49E-04 8.00E-05

CH-ODCM-0001 Reference Use Page 117 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 15 - Ingestion Dose Factors for Child (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 1.16E-07 1.16E-07 1.16E-07 1.16E-07 1.16E-07 1.16E-07 C-14 1.21E-05 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 Na-24 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 P-32 8.25E-04 3.86E-05 3.18E-05 2.28E-05 Cr-51 8.90E-09 4.94E-09 1.35E-09 9.02E-09 4.72E-07 Mn-54 1.07E-05 2.85E-06 3.00E-06 8.98E-06 Mn-56 3.34E-07 7.54E-08 4.04E-07 4.84E-05 Fe-55 1.15E-05 6.10E-06 1.89E-06 3.45E-06 1.13E-06 Fe-59 1.65E-05 2.67E-05 1.33E-05 7.74E-06 2.78E-05 Co-58 1.80E-06 5.51E-06 1.05E-05 Co-60 5.29E-06 1.56E-05 2.93E-05 Ni-59 4.02E-05 1.07E-05 6.82E-06 7.10E-07 Ni-63 5.38E-04 2.88E-05 1.83E-05 1.94E-06 Ni-65 2.22E-06 2.09E-07 1.22E-07 2.56E-05 Cu-64 2.45E-07 1.48E-07 5.92E-07 1.15E-05 Zn-65 1.37E-05 3.65E-05 2.27E-05 2.30E-05 6.41E-06 Zn-69 4.38E-08 6.33E-08 5.85E-09 3.84E-08 3.99E-06 Br-83 1.71E-07 Br-84 1.98E-07 Br-85 9.12E-09 Rb-86 6.70E-05 4.12E-05 4.31E-06 Rb-88 1.90E-07 1.32E-07 9.32E-09 Rb-89 1.17E-07 1.04E-07 1.02E-09 Sr-89 1.32E-03 3.77E-05 5.11E-05 Sr-90 2.56E-02 5.15E-04 2.29E-04 Sr-91 2.40E-05 9.06E-07 5.30E-05 Sr-92 9.03E-06 3.62E-07 1.71E-04 Y-90 4.11E-08 1.10E-09 1.17E-04 Y-91M 3.82E-10 1.39E-11 7.48E-07 Y-91 6.02E-07 1.61E-08 8.02E-05 Y-92 3.60E-09 1.03E-10 1.04E-04 Y-93 1.14E-08 3.13E-10 1.70E-04 Zr-95 1.16E-07 2.55E-08 2.27E-08 3.65E-08 2.66E-05 Zr-97 6.99E-09 1.01E-09 5.96E-10 1.45E-09 1.53E-04 Nb-95 2.25E-08 8.76E-09 6.26E-09 8.23E-09 1.62E-05 Mo-99 1.33E-05 3.29E-06 2.84E-05 1.10E-05

CH-ODCM-0001 Reference Use Page 118 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 15 - Ingestion Dose Factors for Child (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 9.23E-10 1.81E-09 3.00E-08 2.63E-08 9.19E-10 1.03E-06 Tc-101 1.07E-09 1.12E-09 1.42E-08 1.91E-08 5.92E-10 3.56E-09 Ru-103 7.31E-07 2.81E-07 1.84E-06 1.89E-05 Ru-105 6.45E-08 2.34E-08 5.67E-07 4.21E-05 Ru-106 1.17E-05 1.46E-06 1.58E-05 1.82E-04 Ag-110M 5.39E-07 3.64E-07 2.91E-07 6.78E-07 4.33E-05 Sb-124 1.11E-05 1.44E-07 3.89E-06 2.45E-08 6.16E-06 6.94E-05 Sb-125 7.16E-06 5.52E-08 1.50E-06 6.63E-09 3.99E-06 1.71E-05 Te-125M 1.14E-05 3.09E-06 1.52E-06 3.20E-06 1.10E-05 Te-127M 2.89E-05 7.78E-06 3.43E-06 6.91E-06 8.24E-05 2.34E-05 Te-127 4.71E-07 1.27E-07 1.01E-07 3.26E-07 1.34E-06 1.84E-05 Te-129M 4.87E-05 1.36E-05 7.56E-06 1.57E-05 1.43E-04 5.94E-05 Te-129 1.34E-07 3.74E-08 3.18E-08 9.56E-08 3.92E-07 8.34E-06 Te-131M 7.20E-06 2.49E-06 2.65E-06 5.12E-06 2.41E-05 1.01E-04 Te-131 8.30E-08 2.53E-08 2.47E-08 6.35E-08 2.51E-07 4.36E-07 Te-132 1.01E-05 4.47E-06 5.40E-06 6.51E-06 4.15E-05 4.50E-05 I-130 2.92E-06 5.90E-06 3.04E-06 6.50E-04 8.82E-06 2.76E-06 I-131 1.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 1.54E-06 I-132 8.00E-07 1.47E-06 6.76E-07 6.82E-05 2.25E-06 1.73E-06 I-133 5.92E-06 7.32E-06 2.77E-06 1.36E-03 1.22E-05 2.95E-06 I-134 4.19E-07 7.78E-07 3.58E-07 1.79E-05 1.19E-06 5.16E-07 I-135 1.75E-06 3.15E-06 1.49E-06 2.79E-04 4.83E-06 2.40E-06 Cs-134 2.34E-04 3.84E-04 8.10E-05 1.19E-04 4.27E-05 2.07E-06 Cs-136 2.35E-05 6.46E-05 4.18E-05 3.44E-05 5.13E-06 2.27E-06 Cs-137 3.27E-04 3.13E-04 4.62E-05 1.02E-04 3.67E-05 1.96E-06 Cs-138 2.28E-07 3.17E-07 2.01E-07 2.23E-07 2.40E-08 1.46E-07 Ba-139 4.14E-07 2.21E-10 1.20E-08 1.93E-10 1.30E-10 2.39E-05 Ba-140 8.31E-05 7.28E-08 4.85E-06 2.37E-08 4.34E-08 4.21E-05 Ba-141 2.00E-07 1.12E-10 6.51E-09 9.69E-11 6.58E-10 1.14E-07 Ba-142 8.74E-08 6.29E-11 4.88E-09 5.09E-11 3.70E-11 1.14E-09 La-140 1.01E-08 3.53E-09 1.19E-09 9.84E-05 La-142 5.24E-10 1.67E-10 5.23E-11 3.31E-05 Ce-141 3.97E-08 1.98E-08 2.94E-09 8.68E-09 2.47E-05 Ce-143 6.99E-09 3.79E-06 5.49E-10 1.59E-09 5.55E-05 Ce-144 2.08E-06 6.52E-07 1.11E-07 3.61E-07 1.70E-04 Pr-143 3.93E-08 1.18E-08 1.95E-09 6.39E-09 4.24E-05

CH-ODCM-0001 Reference Use Page 119 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 15 - Ingestion Dose Factors for Child (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 1.29E-10 3.99E-11 6.49E-12 2.11E-11 8.59E-08 Nd-147 2.79E-08 2.26E-08 1.75E-09 1.24E-08 3.58E-05 W-187 4.29E-07 2.54E-07 1.14E-07 3.57E-05 Pu-238 1.19E-03 1.38E-04 3.16E-05 1.15E-04 7.50E-05 Pu-239 1.29E-03 1.38E-04 3.31E-05 1.22E-04 6.85E-05 Pu-240 1.28E-03 1.43E-04 3.31E-05 1.22E-04 6.98E-05 Pu-241 3.87E-05 1.58E-06 8.04E-07 2.96E-06 1.44E-06 Np-239 5.25E-09 3.77E-10 2.65E-10 1.09E-09 2.79E-05 Am-241 1.36E-03 1.17E-03 1.02E-04 6.23E-04 7.64E-05 Cm-242 8.78E-05 7.01E-05 5.84E-06 1.87E-05 8.16E-05 Cm-243 1.28E-03 1.04E-03 8.24E-05 3.08E-04 8.03E-05 Cm-244 1.08E-03 8.74E-04 6.93E-05 2.54E-04 7.77E-05

CH-ODCM-0001 Reference Use Page 120 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 16 - Ingestion Dose Factors for Infant (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 1.76E-07 1.76E-07 1.76E-07 1.76E-07 1.76E-07 1.76E-07 C-14 2.37E-05 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 Na-24 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 P-32 1.70E-03 1.00E-04 6.59E-05 2.30E-05 Cr-51 1.41E-08 9.20E-09 2.01E-09 1.79E-08 4.11E-07 Mn-54 1.99E-05 4.51E-06 4.41E-06 7.31E-06 Mn-56 8.18E-07 1.41E-07 7.03E-07 7.43E-05 Fe-55 1.39E-05 8.98E-06 2.40E-06 4.36E-06 1.14E-06 Fe-59 3.08E-05 5.38E-05 2.12E-05 1.59E-05 2.57E-05 Co-58 3.60E-06 8.98E-06 8.97E-06 Co-60 1.08E-05 2.55E-05 2.57E-05 Ni-59 4.73E-05 1.45E-05 8.17E-06 7.16E-07 Ni-63 6.34E-04 3.92E-05 2.20E-05 1.95E-06 Ni-65 4.70E-06 5.32E-07 2.42E-07 4.05E-05 Cu-64 6.09E-07 2.82E-07 1.03E-06 1.25E-05 Zn-65 1.84E-05 6.31E-05 2.91E-05 3.06E-05 5.33E-05 Zn-69 9.33E-08 1.68E-07 1.25E-08 6.98E-08 1.37E-05 Br-83 3.63E-07 Br-84 3.82E-07 Br-85 1.94E-08 Rb-86 1.70E-04 8.40E-05 4.35E-06 Rb-88 4.98E-07 2.73E-07 4.85E-07 Rb-89 2.86E-07 1.97E-07 9.74E-08 Sr-89 2.51E-03 7.20E-05 5.16E-05 Sr-90 2.83E-02 5.74E-04 2.31E-04 Sr-91 5.00E-05 1.81E-06 5.92E-05 Sr-92 1.92E-05 7.13E-07 2.07E-04 Y-90 8.69E-08 2.33E-09 1.20E-04 Y-91M 8.10E-10 2.76E-11 2.70E-06 Y-91 1.13E-06 3.01E-08 8.10E-05 Y-92 7.65E-09 2.15E-10 1.46E-04 Y-93 2.43E-08 6.62E-10 1.92E-04 Zr-95 2.06E-07 5.02E-08 3.56E-08 5.41E-08 2.50E-05 Zr-97 1.48E-08 2.54E-09 1.16E-09 2.56E-09 1.62E-04 Nb-95 4.20E-08 1.73E-08 1.00E-08 1.24E-08 1.46E-05 Mo-99 3.40E-05 6.63E-06 5.08E-05 1.12E-05

CH-ODCM-0001 Reference Use Page 121 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 16 - Ingestion Dose Factors for Infant (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-99M 1.92E-09 3.96E-09 5.10E-08 4.26E-08 2.07E-09 1.15E-06 Tc-101 2.27E-09 2.86E-09 2.83E-08 3.40E-08 1.56E-09 4.86E-07 Ru-103 1.48E-06 4.95E-07 3.08E-06 1.80E-05 Ru-105 1.36E-07 4.58E-08 1.00E-06 5.41E-05 Ru-106 2.41E-05 3.01E-06 2.85E-05 1.83E-04 Ag-110M 9.96E-07 7.27E-07 4.81E-07 1.04E-06 3.77E-05 Sb-124 2.14E-05 3.15E-07 6.63E-06 5.68E-08 1.34E-05 6.60E-05 Sb-125 1.23E-05 1.19E-07 2.53E-06 1.54E-08 7.12E-06 1.64E-05 Te-125M 2.33E-05 7.79E-06 3.15E-06 7.84E-06 1.11E-05 Te-127M 5.85E-05 1.94E-05 7.08E-06 1.69E-05 1.44E-04 2.36E-05 Te-127 1.00E-06 3.35E-07 2.15E-07 8.14E-07 2.44E-06 2.10E-05 Te-129M 1.00E-04 3.43E-05 1.54E-05 3.84E-05 2.50E-04 5.97E-05 Te-129 2.84E-07 9.79E-08 6.63E-08 2.38E-07 7.07E-07 2.27E-05 Te-131M 1.52E-05 6.12E-06 5.05E-06 1.24E-05 4.21E-05 1.03E-04 Te-131 1.76E-07 6.50E-08 4.94E-08 1.57E-07 4.50E-07 7.11E-06 Te-132 2.08E-05 1.03E-05 9.61E-06 1.52E-05 6.44E-05 3.81E-05 I-130 6.00E-06 1.32E-05 5.30E-06 1.48E-03 1.45E-05 2.83E-06 I-131 3.59E-05 4.23E-05 1.86E-05 1.39E-02 4.94E-05 1.51E-06 I-132 1.66E-06 3.37E-06 1.20E-06 1.58E-04 3.76E-06 2.73E-06 I-133 1.25E-05 1.82E-05 5.33E-06 3.31E-03 2.14E-05 3.08E-06 I-134 8.69E-07 1.78E-06 6.33E-07 4.15E-05 1.99E-06 1.84E-06 I-135 3.64E-06 7.24E-06 2.64E-06 6.49E-04 8.07E-06 2.62E-06 Cs-134 3.77E-04 7.03E-04 7.10E-05 1.81E-04 7.42E-05 1.91E-06 Cs-136 4.59E-05 1.35E-04 5.04E-05 5.38E-05 1.10E-05 2.05E-06 Cs-137 5.22E-04 6.11E-04 4.33E-05 1.64E-04 6.64E-05 1.91E-06 Cs-138 4.81E-07 7.82E-07 3.79E-07 3.90E-07 6.09E-08 1.25E-06 Ba-139 8.81E-07 5.84E-10 2.55E-08 3.51E-10 3.54E-10 5.58E-05 Ba-140 1.71E-04 1.71E-07 8.81E-06 4.06E-08 1.05E-07 4.20E-05 Ba-141 4.25E-07 2.91E-10 1.34E-08 1.75E-10 1.77E-10 5.19E-06 Ba-142 1.84E-07 1.53E-10 9.06E-09 8.81E-11 9.26E-11 7.59E-07 La-140 2.11E-08 8.32E-09 2.14E-09 9.77E-05 La-142 1.10E-09 4.04E-10 9.67E-11 6.86E-05 Ce-141 7.87E-08 4.80E-08 5.65E-09 1.48E-08 2.48E-05 Ce-143 1.48E-08 9.82E-06 1.12E-09 2.86E-09 5.73E-05 Ce-144 2.98E-06 1.22E-06 1.67E-07 4.93E-07 1.71E-04 Pr-143 8.13E-08 3.04E-08 4.03E-09 1.13E-08 4.29E-05

CH-ODCM-0001 Reference Use Page 122 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 16 - Ingestion Dose Factors for Infant (mrem per pCi Ingested)

Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Pr-144 2.74E-10 1.06E-10 1.38E-11 3.84E-11 4.93E-06 Nd-147 5.53E-08 5.68E-08 3.48E-09 2.19E-08 3.60E-05 W-187 9.03E-07 6.28E-07 2.17E-07 3.69E-05 Pu-238 1.28E-03 1.50E-04 3.40E-05 1.21E-04 7.57E-05 Pu-239 1.38E-03 1.55E-04 3.54E-05 1.28E-04 6.91E-05 Pu-240 1.38E-03 1.55E-04 3.54E-05 1.28E-04 7.04E-05 Pu-241 4.25E-05 1.76E-06 8.82E-07 3.17E-06 1.45E-06 Np-239 1.11E-08 9.93E-10 5.61E-10 1.98E-09 2.87E-05 Am-241 1.46E-03 1.27E-03 1.09E-04 6.55E-04 7.70E-05 Cm-242 1.37E-04 1.27E-04 9.10E-06 2.62E-05 8.23E-05 Cm-243 1.40E-03 1.15E-03 8.98E-05 3.27E-04 8.10E-05 Cm-244 1.18E-03 9.70E-04 7.59E-05 2.71E-04 7.84E-05

CH-ODCM-0001 Reference Use Page 123 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 17 - Recommended Values for Other Parameters Parameter Symbol Definition Values fg Fraction of ingested produce grown in garden of interest.

0.76 f

Fraction of leafy vegetables grown in garden of interest.

1.0 P

Effective surface density of soil (assumes a 15 cm plow layer, expressed in dry weight) 240 kg/m2 r

Fraction of deposited activity retained on crops, leafy vegetables, or pasture grass 0.25 1.0 (iodines) 0.2 (other particulates)

Sf Attenuation factor accounting for shielding provided by residential structures 0.7 (maximum individual) 0.5 (general population) tb Period of long-term buildup for activity in sediment or soil (20 years) 1.752E5 hr te Period of crop, leafy vegetable, or pasture grass exposure during growing season 30 days (grass-cow-milk-man pathway) 60 days (crop/vegetation-man pathway) tf Transport time from animal feed-milk-man provided by residential structures 2 days (maximum individual) 4 days (general population) th Time delay between harvest of vegetation or crops and ingestion:

For ingestion of forage by animals Zero (pasture grass) 90 days (stored feed)

For ingestion of crops by man 1 day (leafy vegetables and max. individual feed) 60 days (produce and max.

individual) 14 days (general population) fs The fraction of daily feed that is pasture grass while the animals graze on pasture.

1.0 Mp The mixing ratio at the point of withdrawal of drinking water.

Site Discharge 7.14 M.U.D. Intake 30.8 fp Fraction of the year that animals graze on pasture.

0.5

CH-ODCM-0001 Reference Use Page 124 of 124 Off-Site Dose Calculation Manual (ODCM)

Revision 37 (Req Reviews: Rad Review, ISR, RP)

Table 17 - Recommended Values for Other Parameters Parameter Symbol Definition Values tp Environmental transit time, release to receptor (add time from release to exposure individual point to minimums shown for distribution) 12 hrs. (maximum) 1 day (maximum individual) 1 day (general population) 7 days (population--sport fish doses) 10 days (population--

commercial fish doses) ts Average time from slaughter of meat animal to consumption 20 days Yv Agricultural productivity by unit area (measured in wet weight) 0.7 kg/m2 (grass-cow-milk-man pathway) 2.0 kg/m2 (produce or leafy vegetable ingested by man)

W Shore-width factor for river shoreline 0.2 w

Rate constant for removal of activity on plant or leaf structures by weathering (corresponds to a 14-day half-life) 0.0021 hr-1