ML21270A023

From kanterella
Jump to navigation Jump to search

State of Virginia Notification of Pending Amendment Issuance Ref: Surry Power Station, Units 1 and 2 - Request to Revise Technical Specifications 2.1.A.1.b
ML21270A023
Person / Time
Site: Surry  
(DPR-032, DPR-037)
Issue date: 07/07/2021
From: Harrison S
State of VA, Dept of Health
To: Vaughn Thomas
NRC/NRR/DORL/LPL2-1
J Klos
Shared Package
ML20309A875 List: ... further results
References
WCAP-17642-P-A
Download: ML21270A023 (2)


Text

1 From:

Harrison, Steven <steve.harrison@vdh.virginia.gov>

Sent:

Wednesday, July 07, 2021 10:04 AM To:

Thomas, Vaughn Cc:

Lea Perlas; RadHealth-Comments@vdh.virginia.gov

Subject:

[External_Sender] Re: State Notification of Amendments to Surry Power Station, Units 1 and 2 -

Request to Revise Technical Specifications 2.1.A.1.b Mr.Thomas:

TheVirginiaDepartmentofHealthsOfficeofRadiologicalHealthhasnoquestionsorcommentsinfavorofor oppositiontothesubjectamendments.

PleasenotethatIamonleaveuntilretirement,andLePerlasisservingastheInterimDirector.

Thankyou, SteveHarrison OnWed,Jul7,2021at8:57AMThomas,Vaughn<Vaughn.Thomas@nrc.gov>wrote:
Hello, The Nuclear Regulatory Commission (NRC) staff is nearing its completion of the amendments for the Surry Power Station, Units 1 and 2 to permit the licensee to revise Technical Specifications 2.1.A.1.b, Safety Limit Reactor Core, to reflect the peak fuel centerline melt temperature specified in WCAP-17642-P-A, Revision 1, Westinghouse Performance Analysis and Design Model (PAD5).

The application is dated September 30, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20274A329).

The no significant hazards consideration determination was noticed in the Federal Register on December 29, 2020 Vol. 85, No. 249 (FRN: 85 FR 85678), Attached.

Please respond if you have any or no comments.

Thank you,

2 Vaughn Thomas, Project Manager PlantLicensingBranchII1 DivisionofOperatingReactorLicensing OfficeofNuclearReactorRegulation Vaughn.Thomas@nrc.gov 3014155897

Steven A. Harrison, MA, MEP Director, Office of Radiological Health Virginia Department of Health 109 Governor St., 7th Floor Richmond, VA 23219 O: 804-864-8151 M: 804-396-5360