ML20309A721

From kanterella
Jump to navigation Jump to search
2 to Updated Final Safety Analysis Report, Chapter 5, Appendix 5B, Figures
ML20309A721
Person / Time
Site: McGuire, Mcguire  
Issue date: 10/08/2020
From:
Duke Energy Carolinas
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20309A875 List: ... further results
References
RA-19-0424
Download: ML20309A721 (33)


Text

McGuire Nuclear Station UFSAR Appendix 5B. Figures Appendix 5B. Figures

McGuire Nuclear Station UFSAR Figure 5-1 (Page 1 of 1)

(10 OCT 2009)

Figure 5-1. Flow Diagram of Reactor Coolant System

McGuire Nuclear Station UFSAR Figure 5-2 (Page 1 of 1)

(14 OCT 2000)

Figure 5-2. Deleted Per 1994 Update

McGuire Nuclear Station UFSAR Figure 5-3 (Page 1 of 1)

(14 OCT 2000)

Figure 5-3. Pump Head - Flow Characteristics

McGuire Nuclear Station UFSAR Figure 5 5-7 (Page 1 of 1)

(27 MAR 2002)

Figure 5-4. Deleted Per 1998 Update Figure 5-5. Deleted Per 1998 Update Figure 5-6. Deleted Per 1998 Update Figure 5-7. Deleted Per 1998 Update

McGuire Nuclear Station UFSAR Figure 5-8 (Page 1 of 1)

(14 OCT 2000)

Figure 5-8. Reactor Coolant Loop/Supports System Dynamic - Westinghouse Structural Model

McGuire Nuclear Station UFSAR Figure 5-9 (Page 1 of 1)

(27 MAR 2002)

Figure 5-9. Deleted Per 1998 Update

McGuire Nuclear Station UFSAR Figure 5-10 (Page 1 of 1)

(14 OCT 2000)

Figure 5-10. Power Operated Relief Valve Flow Characteristics

McGuire Nuclear Station UFSAR Figure 5 5-14 (Page 1 of 1)

(14 OCT 2000)

Figure 5-11. Deleted Per 1997 Update Figure 5-12. Deleted Per 1997 Update Figure 5-13. Deleted Per 1997 Update Figure 5-14. Deleted per 1997 Update

McGuire Nuclear Station UFSAR Figure 5 5-16 (Page 1 of 1)

(24 APR 2014)

Figure 5-15. Deleted Per 2014 Update Figure 5-16. Deleted Per 2014 Update

McGuire Nuclear Station UFSAR Figure 5-17 (Page 1 of 1)

(14 OCT 2000)

Figure 5-17. KID Lower bound Fracture Toughness A533V (Reference WCAP 7623) Grade B Class 1

McGuire Nuclear Station UFSAR Figure 5-18 (Page 1 of 1)

(14 OCT 2000)

Figure 5-18. Nominal Containment Sump Level Change Rate Versus Leakage Rate

McGuire Nuclear Station UFSAR Figure 5-19 (Page 1 of 1)

(09 OCT 2015)

Figure 5-19. Relationship Between Reactor Coolant System Temperature and Power Note 1 - Thot = 614.6ºF, and Tcold = 555.6ºF.

McGuire Nuclear Station UFSAR Figure 5-20 (Page 1 of 1)

(14 OCT 2000)

Figure 5-20. Reactor Vessel Head View Showing Top-Mounted Control Drive Mechanism Housing Locations

McGuire Nuclear Station UFSAR Figure 5-21 (Page 1 of 1)

(14 OCT 2000)

Figure 5-21. Surveillance Capsule for Unit 1-Elevation View

McGuire Nuclear Station UFSAR Figure 5-22 (Page 1 of 1)

(14 OCT 2000)

Figure 5-22. Surveillance Capsule for Unit 2-Elevation View

McGuire Nuclear Station UFSAR Figure 5-23 (Page 1 of 1)

(14 OCT 2000)

Figure 5-23. Surveillance Capsule Plan View (Representative for Unit 1, Unit 2 Similar)

McGuire Nuclear Station UFSAR Figure 5-24 (Page 1 of 1)

(14 OCT 2000)

Figure 5-24. Reactor Coolant Controlled Leakage Pumps

McGuire Nuclear Station UFSAR Figure 5-25 (Page 1 of 1)

(14 OCT 2000)

Figure 5-25. Estimated Performance Curve - Controlled Leakage Main Coolant Pump

McGuire Nuclear Station UFSAR Figure 5-26 (Page 1 of 1)

(14 OCT 2000)

Figure 5-26. Reactor Coolant Pump Spool Piece and Motor Support Stand

McGuire Nuclear Station UFSAR Figure 5-27 (Page 1 of 1)

(14 OCT 2000)

Figure 5-27. BWI Steam Generator

McGuire Nuclear Station UFSAR Figure 5-28 (Page 1 of 1)

(10 OCT 2009)

Figure 5-28. Flow Diagram of Residual Heat Removal System (ND)

McGuire Nuclear Station UFSAR Figure 5-29 (Page 1 of 1)

(14 OCT 2000)

Figure 5-29. Pressurizer

McGuire Nuclear Station UFSAR Figure 5-30 (Page 1 of 1)

(14 OCT 2000)

Figure 5-30. Typical Steam Generator Lower Lateral Support

McGuire Nuclear Station UFSAR Figure 5-31 (Page 1 of 1)

(14 OCT 2000)

Figure 5-31. Typical Steam Generator Upper Support

McGuire Nuclear Station UFSAR Figure 5-32 (Page 1 of 1)

(14 OCT 2000)

Figure 5-32. Typical Column Assembly for the Steam Generator and Reactor Coolant Pump

McGuire Nuclear Station UFSAR Figure 5-33 (Page 1 of 1)

(14 OCT 2000)

Figure 5-33. Typical Reactor Coolant Pump Lateral Support for Loops 1-2

McGuire Nuclear Station UFSAR Figure 5-34 (Page 1 of 1)

(14 OCT 2000)

Figure 5-34. Typical Reactor Coolant Pump Lateral Support for Loops 3-4

McGuire Nuclear Station UFSAR Figure 5-35 (Page 1 of 1)

(14 OCT 2000)

Figure 5-35. Pressurizer Support System Elevation

McGuire Nuclear Station UFSAR Figure 5-36 (Page 1 of 1)

(14 OCT 2000)

Figure 5-36. Pressurizer Lower Lateral Support

McGuire Nuclear Station UFSAR Figure 5-37 (Page 1 of 1)

(14 OCT 2000)

Figure 5-37. Pressurizer Upper Lateral Support

McGuire Nuclear Station UFSAR Figure 5-38 (Page 1 of 1)

(14 OCT 2000)

Figure 5-38. Typical Reactor Vessel Support

McGuire Nuclear Station UFSAR Figure 5 5-43 (Page 1 of 1)

(14 OCT 2000)

Figure 5-39. Deleted Per 1995 Update Figure 5-40. Deleted Per 1995 Update Figure 5-41. Deleted Per 1995 Update Figure 5-42. Deleted Per 1995 Update Figure 5-43. Deleted Per 1995 Update