Wolf Creek (38.24° N, 95.69° E), Control Point Hazard SA (g)

AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 5.516192e-03 8.378842e-03 1.187879e-02 1.255359e-02 1.267787e-02 1.251489e-02 1.172551e-02 0.001122 5.410096e-03 8.358068e-03 1.187879e-02 1.255343e-02 1.267787e-02 1.251488e-02 1.172551e-02 0.001259 5.224030e-03 8.225707e-03 1.187844e-02 1.255123e-02 1.267787e-02 1.251484e-02 1.172551e-02 0.001413 4.988384e-03 8.008187e-03 1.187334e-02 1.253611e-02 1.267785e-02 1.251454e-02 1.172551e-02 0.001585 4.755277e-03 7.753771e-03 1.184659e-02 1.248723e-02 1.267772e-02 1.251297e-02 1.172480e-02 0.001778 4.529875e-03 7.480728e-03 1.178370e-02 1.240171e-02 1.267693e-02 1.250480e-02 1.170622e-02 0.001995 4.311690e-03 7.154856e-03 1.167297e-02 1.229039e-02 1.267359e-02 1.247446e-02 1.162052e-02 0.002239 4.099650e-03 6.805876e-03 1.148782e-02 1.215333e-02 1.266331e-02 1.240719e-02 1.144376e-02 0.002512 3.893087e-03 6.461784e-03 1.123930e-02 1.198624e-02 1.263845e-02 1.229740e-02 1.118509e-02 0.002818 3.690685e-03 6.125644e-03 1.095285e-02 1.178725e-02 1.258918e-02 1.215297e-02 1.087625e-02 0.003162 3.491847e-03 5.798273e-03 1.063916e-02 1.155668e-02 1.250939e-02 1.198079e-02 1.053760e-02 0.003548 3.295209e-03 5.480184e-03 1.030091e-02 1.129520e-02 1.240055e-02 1.178082e-02 1.017090e-02 0.003981 3.100274e-03 5.171549e-03 9.939995e-03 1.100336e-02 1.226528e-02 1.155232e-02 9.778416e-03 0.004467 2.905737e-03 4.872229e-03 9.558824e-03 1.068191e-02 1.210348e-02 1.129472e-02 9.363068e-03 0.005012 2.711319e-03 4.581665e-03 9.159961e-03 1.033204e-02 1.191398e-02 1.100777e-02 8.927984e-03 0.005623 2.516198e-03 4.299314e-03 8.746339e-03 9.955392e-03 1.169547e-02 1.069178e-02 8.476556e-03 0.006310 2.320644e-03 4.024090e-03 8.321196e-03 9.554109e-03 1.144683e-02 1.034792e-02 8.012474e-03 0.007079 2.124791e-03 3.755197e-03 7.887903e-03 9.130803e-03 1.116741e-02 9.978016e-03 7.539352e-03 0.007943 1.930554e-03 3.491322e-03 7.449656e-03 8.688484e-03 1.085733e-02 9.584408e-03 7.060503e-03 0.008913 1.741825e-03 3.231736e-03 7.009527e-03 8.230391e-03 1.051747e-02 9.169774e-03 6.578922e-03 0.010000 1.557218e-03 2.975485e-03 6.570214e-03 7.759810e-03 1.014933e-02 8.737097e-03 6.097355e-03 0.011220 1.377935e-03 2.722490e-03 6.134081e-03 7.279972e-03 9.755010e-03 8.289530e-03 5.618449e-03 0.012589 1.205302e-03 2.472759e-03 5.702995e-03 6.794026e-03 9.337088e-03 7.830330e-03 5.144839e-03 0.014125 1.041740e-03 2.227509e-03 5.278341e-03 6.305068e-03 8.898513e-03 7.362734e-03 4.679279e-03 0.015849 8.889984e-04 1.989379e-03 4.861071e-03 5.816084e-03 8.442506e-03 6.889946e-03 4.224854e-03 0.017783 7.487050e-04 1.759032e-03 4.451800e-03 5.330109e-03 7.972420e-03 6.415141e-03 3.785071e-03 0.019953 6.218541e-04 1.538780e-03 4.051166e-03 4.850364e-03 7.491650e-03 5.941483e-03 3.365940e-03 0.022387 5.095116e-04 1.329977e-03 3.659785e-03 4.380142e-03 7.003593e-03 5.472049e-03 2.970004e-03 0.025119 4.117222e-04 1.135748e-03 3.278773e-03 3.923113e-03 6.511657e-03 5.009738e-03 2.594830e-03 0.028184 3.280657e-04 9.573598e-04 2.909923e-03 3.483349e-03 6.019270e-03 4.557188e-03 2.242285e-03 0.031623 2.577351e-04 7.961626e-04 2.555798e-03 3.065010e-03 5.529906e-03 4.117704e-03 1.920012e-03 0.035481 1.996509e-04 6.526405e-04 2.219542e-03 2.672213e-03 5.047160e-03 3.691654e-03 1.631025e-03 0.039811 1.525668e-04 5.275456e-04 1.904339e-03 2.308935e-03 4.574797e-03 3.283684e-03 1.375736e-03 0.044668 1.149829e-04 4.200730e-04 1.613503e-03 1.977257e-03 4.116809e-03 2.900818e-03 1.153288e-03 0.050119 8.550259e-05 3.296708e-04 1.349275e-03 1.678001e-03 3.677117e-03 2.545370e-03 9.616625e-04 0.056234 6.273175e-05 2.548883e-04 1.113032e-03 1.411708e-03 3.258738e-03 2.218513e-03 7.983306e-04 0.063096 4.547888e-05 1.943311e-04 9.053550e-04 1.178025e-03 2.864228e-03 1.920971e-03 6.603214e-04 0.070795 3.254360e-05 1.460088e-04 7.262571e-04 9.755568e-04 2.496847e-03 1.652915e-03 5.445970e-04 0.079433 2.305010e-05 1.082728e-04 5.746928e-04 8.020785e-04 2.159345e-03 1.413831e-03 4.481085e-04 0.089125 1.615158e-05 7.923320e-05 4.489042e-04 6.550029e-04 1.853025e-03 1.202613e-03 3.680545e-04 0.100000 1.123201e-05 5.731240e-05 3.463852e-04 5.315668e-04 1.578206e-03 1.017664e-03 3.017938e-04 0.112202 7.757118e-06 4.100879e-05 2.643242e-04 4.289881e-04 1.334472e-03 8.570567e-04 2.461102e-04 0.125893 5.342144e-06 2.907750e-05 1.997309e-04 3.445277e-04 1.120728e-03 7.186520e-04 1.975681e-04 0.141254 3.670059e-06 2.044476e-05 1.496914e-04 2.755883e-04 9.352924e-04 6.002216e-04 1.564584e-04 0.158489 2.524428e-06 1.428387e-05 1.114751e-04 2.197431e-04 7.760360e-04 4.995164e-04 1.234161e-04

0.177828 1.737495e-06 9.943891e-06 8.265607e-05 1.747867e-04 6.405379e-04 4.142839e-04 9.733206e-05 0.199526 1.203682e-06 6.919065e-06 6.115212e-05 1.387808e-04 5.262190e-04 3.423211e-04 7.665442e-05 0.223872 8.404181e-07 4.822597e-06 4.523712e-05 1.100695e-04 4.304521e-04 2.816817e-04 6.014168e-05 0.251189 5.936687e-07 3.376818e-06 3.353046e-05 8.725716e-05 3.506675e-04 2.308026e-04 4.699778e-05 0.281838 4.256267e-07 2.386922e-06 2.494362e-05 6.917392e-05 2.844836e-04 1.883433e-04 3.660683e-05 0.316228 3.099587e-07 1.705511e-06 1.864794e-05 5.484972e-05 2.298127e-04 1.530573e-04 2.842527e-05 0.354813 2.294517e-07 1.235007e-06 1.401965e-05 4.349867e-05 1.848758e-04 1.238470e-04 2.197482e-05 0.398107 1.721158e-07 9.073341e-07 1.060230e-05 3.449644e-05 1.481633e-04 9.980772e-05 1.688566e-05 0.446684 1.309426e-07 6.784006e-07 8.068630e-06 2.734841e-05 1.183789e-04 8.015461e-05 1.289417e-05 0.501187 1.005598e-07 5.143914e-07 6.178747e-06 2.166551e-05 9.436014e-05 6.415515e-05 9.783184e-06 0.562341 7.776170e-08 3.946241e-07 4.756716e-06 1.714331e-05 7.504952e-05 5.116663e-05 7.368842e-06 0.630957 6.039962e-08 3.061823e-07 3.678000e-06 1.353857e-05 5.954931e-05 4.066500e-05 5.508200e-06 0.707946 4.712477e-08 2.402749e-07 2.853270e-06 1.065120e-05 4.714325e-05 3.221130e-05 4.089955e-06 0.794328 3.692633e-08 1.904810e-07 2.218320e-06 8.324394e-06 3.723636e-05 2.542903e-05 3.017998e-06 0.891251 2.903127e-08 1.522613e-07 1.726583e-06 6.451293e-06 2.932068e-05 2.000170e-05 2.212266e-06 1.000000 2.284736e-08 1.225222e-07 1.341833e-06 4.958645e-06 2.299565e-05 1.566550e-05 1.610008e-06 1.122019 1.796346e-08 9.894006e-08 1.039441e-06 3.783389e-06 1.796603e-05 1.220653e-05 1.163398e-06 1.258925 1.410699e-08 7.986694e-08 8.002596e-07 2.867954e-06 1.399855e-05 9.458531e-06 8.352774e-07 1.412538 1.103290e-08 6.417940e-08 6.112237e-07 2.161140e-06 1.088630e-05 7.292136e-06 5.955913e-07 1.584893 8.593421e-09 5.116752e-08 4.629726e-07 1.618825e-06 8.447026e-06 5.600291e-06 4.210165e-07 1.778279 6.682518e-09 4.037715e-08 3.476611e-07 1.205412e-06 6.533623e-06 4.286723e-06 2.950267e-07 1.995262 5.189953e-09 3.152335e-08 2.587383e-07 8.928797e-07 5.033797e-06 3.265599e-06 2.043617e-07 2.238721 4.012805e-09 2.436959e-08 1.908735e-07 6.588329e-07 3.862835e-06 2.469263e-06 1.394165e-07 2.511886 3.074160e-09 1.868024e-08 1.395849e-07 4.850442e-07 2.954635e-06 1.850278e-06 9.373038e-08 2.818383 2.320906e-09 1.420520e-08 1.011108e-07 3.567189e-07 2.253963e-06 1.374285e-06 6.230989e-08 3.162278 1.721310e-09 1.071363e-08 7.235378e-08 2.621656e-07 1.714238e-06 1.012585e-06 4.074532e-08 3.548134 1.253677e-09 8.010050e-09 5.089173e-08 1.924939e-07 1.298353e-06 7.399929e-07 2.607635e-08 3.981072 8.988965e-10 5.940362e-09 3.499130e-08 1.411540e-07 9.775867e-07 5.356061e-07 1.640568e-08 4.466836 6.362361e-10 4.375899e-09 2.346302e-08 1.033765e-07 7.300929e-07 3.831163e-07 1.012687e-08 5.011872 4.455402e-10 3.202215e-09 1.540900e-08 7.561501e-08 5.395293e-07 2.701208e-07 6.008751e-09 5.623413 3.286693e-10 2.426009e-09 1.093914e-08 5.790362e-08 4.120385e-07 1.985207e-07 3.853566e-09 6.309573 2.117984e-10 1.649803e-09 6.469279e-09 4.019224e-08 2.845478e-07 1.269206e-07 1.698380e-09 Wolf Creek (38.24° N, 95.69° E), Response Spectra Frequency (Hz)

UHRS 1E-4 (g)

GMRS (g)

UHRS 1E-5 (g) 0.500000 0.047159 0.053140 0.103680 0.561009 0.051075 0.057480 0.112112 0.629463 0.055707 0.062541 0.121909 0.706269 0.061150 0.068412 0.133237 0.792447 0.067219 0.075057 0.146108 0.889140 0.074076 0.082674 0.160917 0.997631 0.081634 0.091036 0.177159 1.000000 0.081795 0.091217 0.177510 1.122019 0.089672 0.101669 0.198670 1.258925 0.097882 0.112633 0.220911 1.412538 0.106207 0.123926 0.243909 1.584893 0.115619 0.136804 0.270194

1.778279 0.127811 0.153305 0.303819 1.995262 0.142737 0.173168 0.344161 2.238721 0.156296 0.191376 0.381225 2.500000 0.165257 0.204338 0.408045 2.805046 0.170313 0.220839 0.446265 3.147313 0.173794 0.235122 0.480196 3.531344 0.177601 0.249433 0.514212 3.962233 0.185464 0.268941 0.558878 4.445698 0.202323 0.299980 0.626850 4.988156 0.234777 0.348755 0.729117 5.000000 0.235602 0.349918 0.731517 5.610092 0.276965 0.408051 0.851329 6.294627 0.321268 0.471313 0.982271 7.062688 0.371014 0.540003 1.123204 7.924466 0.421783 0.611056 1.269522 8.891397 0.452528 0.659754 1.372864 9.976312 0.485841 0.705245 1.465928 10.000000 0.486632 0.706286 1.468037 11.220185 0.476745 0.694606 1.445149 12.589254 0.455312 0.669761 1.396799 14.125375 0.445334 0.652757 1.360124 15.848932 0.421853 0.618149 1.287914 17.782794 0.407461 0.598950 1.248900 19.952623 0.402401 0.592203 1.235192 22.387211 0.397699 0.587938 1.227685 25.000000 0.391510 0.579859 1.211373 28.050461 0.383499 0.567429 1.185111 31.473135 0.368583 0.542706 1.132095 35.313439 0.342247 0.498892 1.038089 39.622330 0.314152 0.454127 0.942969 44.456985 0.292188 0.418415 0.866771 49.881558 0.275377 0.390232 0.806273 55.968028 0.259960 0.364153 0.750222 62.797161 0.244440 0.338591 0.695605 70.459573 0.229901 0.315017 0.645422 79.056942 0.215548 0.293565 0.600558 88.703347 0.202069 0.275798 0.564515 99.526793 0.189940 0.260980 0.535078 100.000000 0.175511 0.242012 0.496627