Quad Cities (41.73° N, 90.34° E), Control Point Hazard SA (g)

AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.986836e-03 7.852188e-03 1.139994e-02 1.209301e-02 1.223813e-02 1.206386e-02 1.122319e-02 0.001122 4.793872e-03 7.682838e-03 1.133144e-02 1.206207e-02 1.220157e-02 1.203327e-02 1.116846e-02 0.001259 4.563794e-03 7.414921e-03 1.115646e-02 1.200408e-02 1.211954e-02 1.193478e-02 1.100719e-02 0.001413 4.344095e-03 7.102237e-03 1.091523e-02 1.191288e-02 1.200989e-02 1.179263e-02 1.075457e-02 0.001585 4.135747e-03 6.760011e-03 1.063582e-02 1.178421e-02 1.187438e-02 1.162776e-02 1.045037e-02 0.001778 3.937468e-03 6.413233e-03 1.032829e-02 1.161931e-02 1.171374e-02 1.143783e-02 1.011957e-02 0.001995 3.748598e-03 6.074089e-03 9.996009e-03 1.142294e-02 1.152663e-02 1.122098e-02 9.764478e-03 0.002239 3.567214e-03 5.745840e-03 9.641699e-03 1.119778e-02 1.131196e-02 1.097723e-02 9.387957e-03 0.002512 3.392627e-03 5.429367e-03 9.267934e-03 1.094424e-02 1.106873e-02 1.070664e-02 8.993424e-03 0.002818 3.222333e-03 5.125323e-03 8.877469e-03 1.066249e-02 1.079664e-02 1.040951e-02 8.584035e-03 0.003162 3.055822e-03 4.833907e-03 8.473667e-03 1.035325e-02 1.049625e-02 1.008707e-02 8.163014e-03 0.003548 2.890284e-03 4.554700e-03 8.060247e-03 1.001778e-02 1.016905e-02 9.741411e-03 7.733484e-03 0.003981 2.725458e-03 4.287231e-03 7.640973e-03 9.657940e-03 9.816897e-03 9.374969e-03 7.298252e-03 0.004467 2.558777e-03 4.030036e-03 7.219337e-03 9.276164e-03 9.442217e-03 8.990264e-03 6.859470e-03 0.005012 2.390380e-03 3.782103e-03 6.798638e-03 8.875259e-03 9.047624e-03 8.589994e-03 6.418783e-03 0.005623 2.218743e-03 3.541206e-03 6.381567e-03 8.458239e-03 8.635935e-03 8.176767e-03 5.977517e-03 0.006310 2.044692e-03 3.306111e-03 5.970411e-03 8.028169e-03 8.210063e-03 7.753204e-03 5.536897e-03 0.007079 1.868337e-03 3.074491e-03 5.566588e-03 7.588016e-03 7.772717e-03 7.321766e-03 5.098450e-03 0.007943 1.691273e-03 2.845305e-03 5.170883e-03 7.140543e-03 7.326453e-03 6.884709e-03 4.664031e-03 0.008913 1.515868e-03 2.617086e-03 4.783332e-03 6.688249e-03 6.873596e-03 6.444222e-03 4.236224e-03 0.010000 1.343229e-03 2.389718e-03 4.403557e-03 6.233370e-03 6.416503e-03 6.002568e-03 3.818288e-03 0.011220 1.176266e-03 2.163388e-03 4.031055e-03 5.777965e-03 5.957515e-03 5.562183e-03 3.414157e-03 0.012589 1.016554e-03 1.939161e-03 3.665296e-03 5.324070e-03 5.499008e-03 5.125612e-03 3.026091e-03 0.014125 8.674184e-04 1.719401e-03 3.306622e-03 4.873878e-03 5.044000e-03 4.695710e-03 2.653991e-03 0.015849 7.295052e-04 1.506226e-03 2.955832e-03 4.429873e-03 4.595391e-03 4.275520e-03 2.301582e-03 0.017783 6.050374e-04 1.302626e-03 2.614756e-03 3.994988e-03 4.156585e-03 3.866185e-03 1.977450e-03 0.019953 4.942001e-04 1.111009e-03 2.286341e-03 3.572639e-03 3.731502e-03 3.468269e-03 1.685977e-03 0.022387 3.982212e-04 9.343478e-04 1.974435e-03 3.166579e-03 3.324106e-03 3.088343e-03 1.427898e-03 0.025119 3.159521e-04 7.739867e-04 1.682845e-03 2.780696e-03 2.936825e-03 2.731563e-03 1.202517e-03 0.028184 2.471717e-04 6.316274e-04 1.414708e-03 2.418719e-03 2.573218e-03 2.399780e-03 1.007885e-03 0.031623 1.903861e-04 5.074798e-04 1.172754e-03 2.083757e-03 2.236511e-03 2.094674e-03 8.414787e-04 0.035481 1.446978e-04 4.016383e-04 9.586261e-04 1.778045e-03 1.928953e-03 1.816997e-03 7.003758e-04 0.039811 1.083363e-04 3.129368e-04 7.730311e-04 1.503022e-03 1.651558e-03 1.567038e-03 5.815618e-04 0.044668 8.008315e-05 2.402616e-04 6.152578e-04 1.259245e-03 1.404350e-03 1.344004e-03 4.820231e-04 0.050119 5.835178e-05 1.817610e-04 4.838090e-04 1.046243e-03 1.186534e-03 1.146915e-03 3.990007e-04 0.056234 4.201977e-05 1.356524e-04 3.762357e-04 8.626288e-04 9.966385e-04 9.740514e-04 3.299620e-04 0.063096 2.986748e-05 9.990662e-05 2.897899e-04 7.063374e-04 8.327258e-04 8.237264e-04 2.726748e-04 0.070795 2.101455e-05 7.272110e-05 2.213849e-04 5.748435e-04 6.925063e-04 6.938229e-04 2.243690e-04 0.079433 1.462509e-05 5.236066e-05 1.680569e-04 4.653725e-04 5.735374e-04 5.823951e-04 1.838930e-04 0.089125 1.010039e-05 3.736426e-05 1.269821e-04 3.750845e-04 4.733281e-04 4.873085e-04 1.506298e-04 0.100000 6.923473e-06 2.646461e-05 9.569961e-05 3.012166e-04 3.894736e-04 4.066882e-04 1.233049e-04 0.112202 4.727594e-06 1.864792e-05 7.206947e-05 2.411902e-04 3.197132e-04 3.386289e-04 1.008986e-04 0.125893 3.220347e-06 1.310251e-05 5.433330e-05 1.926826e-04 2.619998e-04 2.815556e-04 8.258288e-05 0.141254 2.196306e-06 9.203606e-06 4.106829e-05 1.536604e-04 2.144391e-04 2.339835e-04 6.754175e-05 0.158489 1.504116e-06 6.481414e-06 3.115713e-05 1.223844e-04 1.753240e-04 1.943988e-04 5.506169e-05

0.177828 1.037335e-06 4.586658e-06 2.374110e-05 9.739529e-05 1.432135e-04 1.613697e-04 4.469826e-05 0.199526 7.227477e-07 3.269602e-06 1.817043e-05 7.747732e-05 1.169073e-04 1.338577e-04 3.619926e-05 0.223872 5.090286e-07 2.350536e-06 1.396537e-05 6.162228e-05 9.538026e-05 1.109568e-04 2.928879e-05 0.251189 3.634840e-07 1.706347e-06 1.077156e-05 4.900618e-05 7.776196e-05 9.189938e-05 2.363625e-05 0.281838 2.626823e-07 1.250388e-06 8.331079e-06 3.896583e-05 6.334055e-05 7.600736e-05 1.896796e-05 0.316228 1.922753e-07 9.245211e-07 6.454068e-06 3.097086e-05 5.153546e-05 6.278602e-05 1.512457e-05 0.354813 1.420761e-07 6.886019e-07 5.003040e-06 2.459816e-05 4.187197e-05 5.178193e-05 1.194859e-05 0.398107 1.059776e-07 5.158690e-07 3.876369e-06 1.951201e-05 3.395912e-05 4.261974e-05 9.340612e-06 0.446684 7.943953e-08 3.879437e-07 2.999074e-06 1.544822e-05 2.747568e-05 3.499247e-05 7.242953e-06 0.501187 5.971275e-08 2.923165e-07 2.314953e-06 1.219997e-05 2.216171e-05 2.863420e-05 5.583812e-06 0.562341 4.488025e-08 2.203108e-07 1.781340e-06 9.604363e-06 1.781171e-05 2.333305e-05 4.284016e-06 0.630957 3.367905e-08 1.658243e-07 1.365444e-06 7.531985e-06 1.425612e-05 1.893738e-05 3.270837e-06 0.707946 2.519540e-08 1.245040e-07 1.041948e-06 5.880044e-06 1.135548e-05 1.529829e-05 2.481207e-06 0.794328 1.876016e-08 9.316128e-08 7.911258e-07 4.566909e-06 8.995643e-06 1.229010e-05 1.868039e-06 0.891251 1.388146e-08 6.947027e-08 5.973321e-07 3.527120e-06 7.083732e-06 9.813979e-06 1.393556e-06 1.000000 1.018881e-08 5.158156e-08 4.482606e-07 2.707539e-06 5.541467e-06 7.783643e-06 1.029809e-06 1.122019 7.413557e-09 3.810067e-08 3.341383e-07 2.064705e-06 4.304003e-06 6.128828e-06 7.530313e-07 1.258925 5.342882e-09 2.796882e-08 2.472691e-07 1.563098e-06 3.317792e-06 4.786227e-06 5.448065e-07 1.412538 3.817532e-09 2.039440e-08 1.815189e-07 1.173934e-06 2.537003e-06 3.707743e-06 3.895190e-07 1.584893 2.699920e-09 1.475915e-08 1.320741e-07 8.739943e-07 1.921562e-06 2.847202e-06 2.752039e-07 1.778279 1.890793e-09 1.059791e-08 9.511697e-08 6.445164e-07 1.440716e-06 2.163723e-06 1.919367e-07 1.995262 1.309111e-09 7.541134e-09 6.770661e-08 4.703687e-07 1.067777e-06 1.626981e-06 1.322096e-07 2.238721 8.965544e-10 5.313188e-09 4.757567e-08 3.394198e-07 7.813724e-07 1.209151e-06 8.981353e-08 2.511886 6.058815e-10 3.699665e-09 3.300526e-08 2.419709e-07 5.636946e-07 8.866104e-07 6.010555e-08 2.818383 4.040161e-10 2.543593e-09 2.261286e-08 1.702630e-07 4.000895e-07 6.403363e-07 3.951249e-08 3.162278 2.649745e-10 1.723180e-09 1.529075e-08 1.181297e-07 2.792775e-07 4.544980e-07 2.546869e-08 3.548134 1.706940e-10 1.148270e-09 1.018547e-08 8.074530e-08 1.906911e-07 3.160384e-07 1.603762e-08 3.981072 1.073113e-10 7.508887e-10 6.667817e-09 5.433998e-08 1.268971e-07 2.144089e-07 9.825018e-09 4.466836 6.583143e-11 4.814882e-10 4.274998e-09 3.595899e-08 8.226719e-08 1.409276e-07 5.802924e-09 5.011872 3.905472e-11 3.018454e-10 2.672820e-09 2.333181e-08 5.156794e-08 8.919023e-08 3.187522e-09 5.623413 2.489743e-11 2.039998e-10 1.799073e-09 1.617573e-08 3.421229e-08 5.890511e-08 1.781048e-09 6.309573 1.074014e-11 1.061542e-10 9.253252e-10 9.019647e-09 1.685663e-08 2.861999e-08 3.745752e-10 Quad Cities (41.73° N, 90.34° E), Response Spectra Frequency (Hz)

UHRS 1E-4 (g)

GMRS (g)

UHRS 1E-5 (g) 0.500000 0.041044 0.045905 0.089397 0.561009 0.043761 0.048960 0.095355 0.629463 0.046766 0.052343 0.101953 0.706269 0.050184 0.056130 0.109312 0.792447 0.053923 0.060316 0.117466 0.889140 0.058163 0.065067 0.126720 0.997631 0.062967 0.070468 0.137254 1.000000 0.063074 0.070587 0.137484 1.122019 0.068593 0.078765 0.154403 1.258925 0.074564 0.087639 0.172803 1.412538 0.080295 0.096341 0.190942 1.584893 0.085420 0.104500 0.208120

1.778279 0.089547 0.111545 0.223156 1.995262 0.092930 0.117820 0.236753 2.238721 0.095634 0.123183 0.248513 2.500000 0.098227 0.128283 0.259696 2.805046 0.103286 0.141333 0.289471 3.147313 0.111679 0.158299 0.327090 3.531344 0.125979 0.182811 0.379962 3.962233 0.143604 0.211581 0.441433 4.445698 0.159767 0.238045 0.498039 4.988156 0.175478 0.263176 0.551522 5.000000 0.175809 0.263698 0.552630 5.610092 0.185092 0.283459 0.597141 6.294627 0.191937 0.299156 0.632985 7.062688 0.193254 0.305577 0.648902 7.924466 0.195441 0.312711 0.666018 8.891397 0.206114 0.332427 0.709422 9.976312 0.217735 0.352510 0.752996 10.000000 0.217961 0.352901 0.753846 11.220185 0.220428 0.359809 0.770166 12.589254 0.225534 0.370984 0.795612 14.125375 0.228733 0.379072 0.814482 15.848932 0.230686 0.385440 0.829855 17.782794 0.233294 0.392800 0.847323 19.952623 0.236252 0.400776 0.866151 22.387211 0.238554 0.407690 0.882728 25.000000 0.237911 0.405797 0.878200 28.050461 0.235860 0.401335 0.868022 31.473135 0.232323 0.394085 0.851677 35.313439 0.227539 0.384726 0.830780 39.622330 0.220638 0.372026 0.802800 44.456985 0.212621 0.356892 0.769272 49.881558 0.202574 0.337981 0.727411 55.968028 0.190880 0.316183 0.679273 62.797161 0.176876 0.290841 0.623683 70.459573 0.162746 0.265436 0.568046 79.056942 0.148431 0.240086 0.512731 88.703347 0.134794 0.216329 0.461091 99.526793 0.123236 0.197379 0.420487 100.000000 0.112780 0.180933 0.385611