LaSalle (41.25° N, 88.67° E), Control Point Hazard SA (g) AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 6.785379e-03 1.166012e-02 1.789523e-02 1.917810e-02 1.942200e-02 1.912478e-02 1.763192e-02 0.001122 6.717415e-03 1.165234e-02 1.789503e-02 1.917810e-02 1.942200e-02 1.912478e-02 1.763192e-02 0.001259 6.421452e-03 1.150785e-02 1.789439e-02 1.917810e-02 1.942200e-02 1.912478e-02 1.763192e-02 0.001413 6.049218e-03 1.120374e-02 1.789256e-02 1.917810e-02 1.942200e-02 1.912478e-02 1.763192e-02 0.001585 5.691936e-03 1.077778e-02 1.788798e-02 1.917810e-02 1.942197e-02 1.912478e-02 1.763192e-02 0.001778 5.356221e-03 1.029255e-02 1.787787e-02 1.917809e-02 1.942159e-02 1.912473e-02 1.763191e-02 0.001995 5.040974e-03 9.765424e-03 1.785801e-02 1.917786e-02 1.941824e-02 1.912338e-02 1.763141e-02 0.002239 4.744784e-03 9.210435e-03 1.782315e-02 1.917360e-02 1.939985e-02 1.910847e-02 1.762411e-02 0.002512 4.465912e-03 8.652658e-03 1.776773e-02 1.914168e-02 1.933955e-02 1.902979e-02 1.757703e-02 0.002818 4.202729e-03 8.109539e-03 1.768618e-02 1.903622e-02 1.921576e-02 1.884082e-02 1.741680e-02 0.003162 3.953041e-03 7.588417e-03 1.756955e-02 1.884575e-02 1.903254e-02 1.858590e-02 1.707903e-02 0.003548 3.715093e-03 7.091526e-03 1.739363e-02 1.859138e-02 1.880159e-02 1.828892e-02 1.659568e-02 0.003981 3.486375e-03 6.619712e-03 1.711761e-02 1.828310e-02 1.852608e-02 1.794718e-02 1.604334e-02 0.004467 3.265211e-03 6.173011e-03 1.672975e-02 1.792378e-02 1.820440e-02 1.755834e-02 1.544720e-02 0.005012 3.049137e-03 5.750809e-03 1.625765e-02 1.751454e-02 1.783466e-02 1.712271e-02 1.481298e-02 0.005623 2.836871e-03 5.352086e-03 1.572529e-02 1.705563e-02 1.741566e-02 1.664082e-02 1.414745e-02 0.006310 2.626634e-03 4.975105e-03 1.514680e-02 1.654757e-02 1.694716e-02 1.611415e-02 1.345806e-02 0.007079 2.418010e-03 4.618050e-03 1.453240e-02 1.599215e-02 1.643041e-02 1.554601e-02 1.275213e-02 0.007943 2.211998e-03 4.278429e-03 1.388954e-02 1.539284e-02 1.586829e-02 1.494125e-02 1.203714e-02 0.008913 2.013698e-03 3.954026e-03 1.322439e-02 1.475449e-02 1.526497e-02 1.430555e-02 1.132048e-02 0.010000 1.820900e-03 3.642268e-03 1.254304e-02 1.408290e-02 1.462565e-02 1.364488e-02 1.060872e-02 0.011220 1.632101e-03 3.341258e-03 1.185185e-02 1.338466e-02 1.395635e-02 1.296582e-02 9.907225e-03 0.012589 1.448646e-03 3.049246e-03 1.115726e-02 1.266681e-02 1.326364e-02 1.227461e-02 9.220069e-03 0.014125 1.272139e-03 2.765419e-03 1.046544e-02 1.193666e-02 1.255441e-02 1.157768e-02 8.550220e-03 0.015849 1.105196e-03 2.490511e-03 9.782113e-03 1.120139e-02 1.183542e-02 1.088056e-02 7.899576e-03 0.017783 9.487416e-04 2.227110e-03 9.112331e-03 1.046768e-02 1.111306e-02 1.018837e-02 7.269339e-03 0.019953 8.039773e-04 1.975565e-03 8.460353e-03 9.741431e-03 1.039305e-02 9.505211e-03 6.660245e-03 0.022387 6.716387e-04 1.736682e-03 7.829555e-03 9.027599e-03 9.680401e-03 8.834756e-03 6.072972e-03 0.025119 5.539548e-04 1.511870e-03 7.222319e-03 8.330170e-03 8.979320e-03 8.179896e-03 5.507729e-03 0.028184 4.510050e-04 1.302910e-03 6.640089e-03 7.652062e-03 8.293270e-03 7.543027e-03 4.960391e-03 0.031623 3.623404e-04 1.110964e-03 6.083426e-03 6.995439e-03 7.625132e-03 6.925258e-03 4.417753e-03 0.035481 2.871786e-04 9.367534e-04 5.552223e-03 6.361912e-03 6.977321e-03 6.319394e-03 3.869790e-03 0.039811 2.248392e-04 7.807130e-04 5.045877e-03 5.752753e-03 6.351844e-03 5.695345e-03 3.338743e-03 0.044668 1.739110e-04 6.428963e-04 4.563585e-03 5.169412e-03 5.749661e-03 5.063775e-03 2.851114e-03 0.050119 1.330042e-04 5.231571e-04 4.104598e-03 4.613819e-03 5.169162e-03 4.462754e-03 2.415658e-03 0.056234 1.005667e-04 4.209455e-04 3.668393e-03 4.087775e-03 4.608828e-03 3.904817e-03 2.033573e-03 0.063096 7.530643e-05 3.350789e-04 3.254786e-03 3.592078e-03 4.073084e-03 3.393019e-03 1.703021e-03 0.070795 5.587569e-05 2.641322e-04 2.863519e-03 3.128428e-03 3.570154e-03 2.928907e-03 1.420657e-03 0.079433 4.114604e-05 2.063741e-04 2.494201e-03 2.700207e-03 3.106373e-03 2.512876e-03 1.182054e-03 0.089125 3.011267e-05 1.600710e-04 2.148026e-03 2.310314e-03 2.684773e-03 2.144018e-03 9.816196e-04 0.100000 2.194776e-05 1.233608e-04 1.828056e-03 1.960616e-03 2.306078e-03 1.820353e-03 8.140674e-04 0.112202 1.596469e-05 9.458874e-05 1.536995e-03 1.651611e-03 1.969620e-03 1.538999e-03 6.751120e-04 0.125893 1.162887e-05 7.226362e-05 1.276729e-03 1.382229e-03 1.673739e-03 1.296449e-03 5.551634e-04 0.141254 8.503631e-06 5.510373e-05 1.048254e-03 1.150224e-03 1.416013e-03 1.088778e-03 4.504891e-04 0.158489 6.248014e-06 4.199630e-05 8.513321e-04 9.525914e-04 1.193429e-03 9.114303e-04 3.625236e-04
0.177828 4.628085e-06 3.203117e-05 6.845127e-04 7.858498e-04 1.002555e-03 7.605233e-04 2.912511e-04 0.199526 3.463575e-06 2.448070e-05 5.453483e-04 6.463013e-04 8.397042e-04 6.328516e-04 2.330010e-04 0.223872 2.620971e-06 1.877109e-05 4.307554e-04 5.301809e-04 7.012469e-04 5.250742e-04 1.856709e-04 0.251189 2.005670e-06 1.445393e-05 3.375396e-04 4.338115e-04 5.838555e-04 4.349344e-04 1.465376e-04 0.281838 1.550614e-06 1.118280e-05 2.627513e-04 3.539055e-04 4.844803e-04 3.595009e-04 1.149880e-04 0.316228 1.209697e-06 8.695263e-06 2.035685e-04 2.878809e-04 4.004648e-04 2.964192e-04 8.945940e-05 0.354813 9.497788e-07 6.793657e-06 1.571915e-04 2.336862e-04 3.297658e-04 2.434040e-04 6.896332e-05 0.398107 7.494458e-07 5.330576e-06 1.210603e-04 1.893504e-04 2.706461e-04 1.985967e-04 5.260046e-05 0.446684 5.934828e-07 4.195565e-06 9.308512e-05 1.529523e-04 2.213245e-04 1.609811e-04 3.939812e-05 0.501187 4.705104e-07 3.309213e-06 7.157063e-05 1.230642e-04 1.801474e-04 1.295890e-04 2.917394e-05 0.562341 3.728630e-07 2.613649e-06 5.505328e-05 9.869878e-05 1.457965e-04 1.035785e-04 2.123533e-05 0.630957 2.953103e-07 2.065772e-06 4.231954e-05 7.886348e-05 1.172731e-04 8.213005e-05 1.516607e-05 0.707946 2.337266e-07 1.633292e-06 3.245653e-05 6.259604e-05 9.371461e-05 6.453662e-05 1.064167e-05 0.794328 1.847677e-07 1.291615e-06 2.480859e-05 4.930179e-05 7.433772e-05 5.013552e-05 7.341509e-06 0.891251 1.457173e-07 1.021606e-06 1.888692e-05 3.850857e-05 5.844779e-05 3.845085e-05 4.947880e-06 1.000000 1.143590e-07 8.080539e-07 1.430847e-05 2.978725e-05 4.546799e-05 2.908019e-05 3.261428e-06 1.122019 8.909662e-08 6.385186e-07 1.077370e-05 2.282057e-05 3.496662e-05 2.163444e-05 2.106598e-06 1.258925 6.884894e-08 5.031906e-07 8.046179e-06 1.729965e-05 2.657067e-05 1.579866e-05 1.329638e-06 1.412538 5.272547e-08 3.948021e-07 5.943978e-06 1.294175e-05 1.995037e-05 1.130913e-05 8.168534e-07 1.584893 4.003057e-08 3.080294e-07 4.337769e-06 9.535904e-06 1.477862e-05 7.943036e-06 4.862464e-07 1.778279 3.011844e-08 2.387509e-07 3.130154e-06 6.896048e-06 1.076862e-05 5.483298e-06 2.802672e-07 1.995262 2.241621e-08 1.836491e-07 2.235784e-06 4.900990e-06 7.699495e-06 3.718089e-06 1.556190e-07 2.238721 1.647623e-08 1.400455e-07 1.579943e-06 3.431830e-06 5.387514e-06 2.476908e-06 8.272927e-08 2.511886 1.195286e-08 1.057875e-07 1.103411e-06 2.363411e-06 3.684651e-06 1.613960e-06 4.148152e-08 2.818383 8.562653e-09 7.911852e-08 7.611206e-07 1.599729e-06 2.466788e-06 1.015606e-06 1.921994e-08 3.162278 6.062182e-09 5.856176e-08 5.181951e-07 1.061952e-06 1.617233e-06 6.119185e-07 8.012308e-09 3.548134 4.243953e-09 4.285172e-08 3.480623e-07 6.894407e-07 1.039106e-06 3.508232e-07 2.908171e-09 3.981072 2.937657e-09 3.092568e-08 2.303515e-07 4.346830e-07 6.527503e-07 1.899305e-07 8.739541e-10 4.466836 2.009229e-09 2.194944e-08 1.494375e-07 2.637735e-07 3.981179e-07 9.616014e-08 1.982229e-10 5.011872 1.356593e-09 1.530671e-08 9.427811e-08 1.524797e-07 2.333420e-07 4.492490e-08 3.036116e-11 5.623413 9.741921e-10 1.120831e-08 6.406719e-08 9.787401e-08 1.499621e-07 2.605369e-08 1.526026e-11 6.309573 5.917911e-10 7.109905e-09 3.385627e-08 4.326830e-08 6.658228e-08 7.182480e-09 1.593463e-13 LaSalle (41.25° N, 88.67° E), Response Spectra Frequency (Hz) UHRS 1E-4 (g) GMRS (g) UHRS 1E-5 (g) 0.500000 0.056361 0.067241 0.133078 0.561009 0.061460 0.074429 0.147857 0.629463 0.067296 0.082764 0.165050 0.706269 0.074373 0.092955 0.186122 0.792447 0.083001 0.105563 0.212289 0.889140 0.094203 0.122358 0.247363 0.997631 0.109179 0.145284 0.295494 1.000000 0.109528 0.145824 0.296631 1.122019 0.134540 0.189795 0.391701 1.258925 0.170801 0.247523 0.514289 1.412538 0.221739 0.312909 0.645837 1.584893 0.275901 0.375631 0.768378
1.778279 0.320975 0.431981 0.881098 1.995262 0.366556 0.485963 0.987485 2.238721 0.402774 0.530593 1.076458 2.500000 0.432878 0.569687 1.155486 2.805046 0.461060 0.621074 1.267071 3.147313 0.481399 0.658552 1.348722 3.531344 0.494695 0.684352 1.405483 3.962233 0.506879 0.704839 1.449431 4.445698 0.527790 0.731287 1.502468 4.988156 0.558511 0.760910 1.556753 5.000000 0.559180 0.761524 1.557857 5.610092 0.583334 0.798361 1.635239 6.294627 0.618016 0.841011 1.720138 7.062688 0.644810 0.872065 1.780899 7.924466 0.667126 0.895335 1.824907 8.891397 0.679470 0.902813 1.835548 9.976312 0.684634 0.899783 1.824394 10.000000 0.684741 0.899675 1.824049 11.220185 0.655751 0.852964 1.725001 12.589254 0.627621 0.811938 1.639796 14.125375 0.611937 0.781805 1.574011 15.848932 0.601910 0.758834 1.522691 17.782794 0.588367 0.751142 1.512000 19.952623 0.585065 0.748215 1.506757 22.387211 0.572238 0.730457 1.470314 25.000000 0.552207 0.705646 1.420755 28.050461 0.525293 0.667708 1.342592 31.473135 0.496544 0.625667 1.255308 35.313439 0.473599 0.590432 1.181465 39.622330 0.453171 0.561653 1.122227 44.456985 0.435044 0.534452 1.065524 49.881558 0.416006 0.508930 1.013582 55.968028 0.399064 0.483685 0.961066 62.797161 0.381460 0.460075 0.913028 70.459573 0.365187 0.439160 0.870884 79.056942 0.349428 0.419018 0.830353 88.703347 0.334027 0.401283 0.795571 99.526793 0.320783 0.386540 0.766921 100.000000 0.300480 0.363426 0.721733