Beaver Valley (40.62° N, 80.43° E), Control Point Hazard SA (g)
AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 6.130490e-03 9.633616e-03 1.392452e-02 1.466204e-02 1.474165e-02 1.442106e-02 1.320269e-02 0.001122 6.071736e-03 9.492419e-03 1.392010e-02 1.466196e-02 1.474093e-02 1.442106e-02 1.320269e-02 0.001259 5.875186e-03 9.261076e-03 1.388986e-02 1.466164e-02 1.473886e-02 1.442106e-02 1.320269e-02 0.001413 5.577633e-03 8.931725e-03 1.380435e-02 1.466051e-02 1.473341e-02 1.442097e-02 1.320269e-02 0.001585 5.261996e-03 8.528407e-03 1.365578e-02 1.465724e-02 1.471405e-02 1.441738e-02 1.320222e-02 0.001778 4.953599e-03 8.085765e-03 1.343897e-02 1.464933e-02 1.464672e-02 1.437757e-02 1.319109e-02 0.001995 4.653302e-03 7.629894e-03 1.316066e-02 1.463301e-02 1.451768e-02 1.423301e-02 1.311374e-02 0.002239 4.360337e-03 7.175678e-03 1.283065e-02 1.460328e-02 1.433914e-02 1.399941e-02 1.288275e-02 0.002512 4.073777e-03 6.728181e-03 1.245042e-02 1.455307e-02 1.411638e-02 1.372439e-02 1.249471e-02 0.002818 3.792663e-03 6.288665e-03 1.202237e-02 1.447160e-02 1.385200e-02 1.341124e-02 1.202997e-02 0.003162 3.516264e-03 5.857906e-03 1.155237e-02 1.434496e-02 1.354567e-02 1.305700e-02 1.152246e-02 0.003548 3.244287e-03 5.435977e-03 1.104649e-02 1.416203e-02 1.319668e-02 1.266176e-02 1.097646e-02 0.003981 2.976717e-03 5.023297e-03 1.050959e-02 1.392150e-02 1.280444e-02 1.222645e-02 1.039685e-02 0.004467 2.713892e-03 4.619843e-03 9.945619e-03 1.363004e-02 1.236918e-02 1.175234e-02 9.790020e-03 0.005012 2.456519e-03 4.226064e-03 9.358629e-03 1.329336e-02 1.189237e-02 1.124238e-02 9.162617e-03 0.005623 2.205705e-03 3.842397e-03 8.753000e-03 1.291289e-02 1.137698e-02 1.070127e-02 8.522031e-03 0.006310 1.962958e-03 3.469737e-03 8.133638e-03 1.248841e-02 1.082712e-02 1.013495e-02 7.876637e-03 0.007079 1.730090e-03 3.109436e-03 7.506046e-03 1.202024e-02 1.024815e-02 9.549678e-03 7.234903e-03 0.007943 1.509758e-03 2.762946e-03 6.876238e-03 1.150979e-02 9.646259e-03 8.952487e-03 6.604812e-03 0.008913 1.305722e-03 2.432567e-03 6.250687e-03 1.095977e-02 9.028496e-03 8.350268e-03 5.993507e-03 0.010000 1.118853e-03 2.120149e-03 5.636032e-03 1.037435e-02 8.402276e-03 7.750056e-03 5.407296e-03 0.011220 9.486456e-04 1.828341e-03 5.039051e-03 9.759072e-03 7.775164e-03 7.158244e-03 4.851287e-03 0.012589 7.949803e-04 1.558821e-03 4.466153e-03 9.120614e-03 7.154387e-03 6.580672e-03 4.329514e-03 0.014125 6.581333e-04 1.314332e-03 3.923325e-03 8.466597e-03 6.546687e-03 6.022151e-03 3.844642e-03 0.015849 5.382187e-04 1.096262e-03 3.415598e-03 7.805293e-03 5.958068e-03 5.486764e-03 3.398243e-03 0.017783 4.345164e-04 9.045324e-04 2.947022e-03 7.145287e-03 5.393586e-03 4.977623e-03 2.990683e-03 0.019953 3.460721e-04 7.382078e-04 2.520254e-03 6.495081e-03 4.857289e-03 4.496986e-03 2.620552e-03 0.022387 2.718047e-04 5.960269e-04 2.136785e-03 5.862674e-03 4.352207e-03 4.045993e-03 2.281051e-03 0.025119 2.107040e-04 4.759353e-04 1.796909e-03 5.255218e-03 3.880332e-03 3.621023e-03 1.962307e-03 0.028184 1.613000e-04 3.759729e-04 1.499904e-03 4.678751e-03 3.442686e-03 3.205019e-03 1.669438e-03 0.031623 1.219696e-04 2.938750e-04 1.243714e-03 4.138030e-03 3.039386e-03 2.797263e-03 1.412128e-03 0.035481 9.110873e-05 2.274025e-04 1.025334e-03 3.636457e-03 2.668139e-03 2.421387e-03 1.190485e-03 0.039811 6.731713e-05 1.742183e-04 8.411087e-04 3.176103e-03 2.326480e-03 2.084893e-03 1.000889e-03 0.044668 4.924221e-05 1.323133e-04 6.869532e-04 2.757793e-03 2.015890e-03 1.786294e-03 8.394135e-04 0.050119 3.570540e-05 9.971648e-05 5.589625e-04 2.381173e-03 1.737140e-03 1.523095e-03 7.023595e-04 0.056234 2.568666e-05 7.467470e-05 4.534704e-04 2.044767e-03 1.489410e-03 1.292652e-03 5.863900e-04 0.063096 1.836741e-05 5.564517e-05 3.669909e-04 1.746195e-03 1.270970e-03 1.092207e-03 4.885266e-04 0.070795 1.307651e-05 4.133134e-05 2.963591e-04 1.482750e-03 1.079721e-03 9.189589e-04 4.061316e-04 0.079433 9.290079e-06 3.065500e-05 2.388443e-04 1.251872e-03 9.133887e-04 7.701376e-04 3.369011e-04 0.089125 6.600461e-06 2.274143e-05 1.921448e-04 1.050984e-03 7.696261e-04 6.430482e-04 2.786732e-04 0.100000 4.701475e-06 1.690069e-05 1.543431e-04 8.775006e-04 6.460895e-04 5.351160e-04 2.286713e-04 0.112202 3.365573e-06 1.259757e-05 1.238398e-04 7.290324e-04 5.405105e-04 4.439426e-04 1.846151e-04 0.125893 2.426880e-06 9.427460e-06 9.929328e-05 6.031254e-04 4.507393e-04 3.674149e-04 1.474103e-04 0.141254 1.765152e-06 7.088745e-06 7.957802e-05 4.971333e-04 3.747788e-04 3.036473e-04 1.171440e-04 0.158489 1.295972e-06 5.357498e-06 6.376368e-05 4.084163e-04 3.108127e-04 2.507004e-04 9.268701e-05
0.177828 9.618680e-07 4.070412e-06 5.109214e-05 3.345088e-04 2.572060e-04 2.066722e-04 7.294747e-05 0.199526 7.212694e-07 3.107440e-06 4.094827e-05 2.731765e-04 2.124223e-04 1.699557e-04 5.706213e-05 0.223872 5.462642e-07 2.382884e-06 3.282895e-05 2.224381e-04 1.750130e-04 1.392849e-04 4.436015e-05 0.251189 4.173825e-07 1.834172e-06 2.632317e-05 1.805768e-04 1.437526e-04 1.137391e-04 3.427311e-05 0.281838 3.215003e-07 1.416551e-06 2.110308e-05 1.461253e-04 1.176806e-04 9.254165e-05 2.629623e-05 0.316228 2.491649e-07 1.097130e-06 1.690851e-05 1.178568e-04 9.600978e-05 7.499244e-05 2.001251e-05 0.354813 1.939132e-07 8.518980e-07 1.353456e-05 9.477705e-05 7.805720e-05 6.050528e-05 1.508774e-05 0.398107 1.512736e-07 6.630541e-07 1.082153e-05 7.602389e-05 6.322374e-05 4.859007e-05 1.126439e-05 0.446684 1.181032e-07 5.171150e-07 8.642404e-06 6.080501e-05 5.099500e-05 3.880746e-05 8.320914e-06 0.501187 9.203756e-08 4.041235e-07 6.895555e-06 4.843907e-05 4.094157e-05 3.079206e-05 6.074948e-06 0.562341 7.146975e-08 3.167574e-07 5.498380e-06 3.841545e-05 3.270175e-05 2.427609e-05 4.381184e-06 0.630957 5.527623e-08 2.492801e-07 4.381419e-06 3.035106e-05 2.596813e-05 1.900815e-05 3.118340e-06 0.707946 4.257937e-08 1.971242e-07 3.486138e-06 2.388946e-05 2.048277e-05 1.475753e-05 2.187994e-06 0.794328 3.265975e-08 1.566736e-07 2.763977e-06 1.870896e-05 1.603170e-05 1.134491e-05 1.512795e-06 0.891251 2.491444e-08 1.251682e-07 2.176285e-06 1.455498e-05 1.243857e-05 8.622514e-06 1.029350e-06 1.000000 1.885453e-08 1.004138e-07 1.694861e-06 1.123847e-05 9.557150e-06 6.471009e-06 6.874817e-07 1.122019 1.411746e-08 8.073812e-08 1.303024e-06 8.615028e-06 7.264021e-06 4.791812e-06 4.495313e-07 1.258925 1.043955e-08 6.494859e-08 9.920089e-07 6.559336e-06 5.454493e-06 3.495854e-06 2.871520e-07 1.412538 7.628322e-09 5.214153e-08 7.521456e-07 4.956940e-06 4.041173e-06 2.508048e-06 1.784725e-07 1.584893 5.515584e-09 4.167324e-08 5.694070e-07 3.712927e-06 2.951729e-06 1.766372e-06 1.073935e-07 1.778279 3.946715e-09 3.308331e-08 4.295841e-07 2.751322e-06 2.124820e-06 1.217404e-06 6.191050e-08 1.995262 2.792521e-09 2.603933e-08 3.217527e-07 2.012567e-06 1.506515e-06 8.188174e-07 3.365234e-08 2.238721 1.950803e-09 2.028294e-08 2.384670e-07 1.451919e-06 1.049891e-06 5.364278e-07 1.686068e-08 2.511886 1.342599e-09 1.561258e-08 1.747692e-07 1.033219e-06 7.163933e-07 3.399988e-07 7.366577e-09 2.818383 9.073499e-10 1.186246e-08 1.268893e-07 7.253534e-07 4.760107e-07 2.064337e-07 2.518374e-09 3.162278 6.450594e-10 9.221190e-09 9.600076e-08 5.341198e-07 3.322423e-07 1.361170e-07 1.266834e-09 3.548134 3.827689e-10 6.579919e-09 6.511221e-08 3.428862e-07 1.884739e-07 6.580025e-08 1.529340e-11 Beaver Valley (40.62° N, 80.43° E), Response Spectra Frequency (Hz)
UHRS 1E-4 (g)
GMRS (g)
UHRS 1E-5 (g) 0.500000 0.034201 0.039477 0.077487 0.561009 0.034889 0.040705 0.080112 0.629463 0.036206 0.042731 0.084341 0.706269 0.038828 0.046420 0.091919 0.792447 0.042923 0.052026 0.103375 0.889140 0.046822 0.057260 0.114029 0.997631 0.049994 0.061557 0.122794 1.000000 0.050061 0.061647 0.122979 1.122019 0.053936 0.069884 0.141194 1.258925 0.058940 0.079897 0.163256 1.412538 0.065574 0.092274 0.190316 1.584893 0.071538 0.103783 0.215693 1.778279 0.080320 0.119559 0.250082 1.995262 0.091849 0.139614 0.293565 2.238721 0.105507 0.163413 0.345222 2.500000 0.125428 0.195828 0.414530 2.805046 0.153993 0.246129 0.524070
3.147313 0.193339 0.307785 0.654697 3.531344 0.237776 0.367496 0.775951 3.962233 0.279766 0.424734 0.892810 4.445698 0.316767 0.470796 0.984389 4.988156 0.344900 0.504962 1.051866 5.000000 0.345530 0.505722 1.053366 5.610092 0.354554 0.521915 1.088654 6.294627 0.355949 0.526667 1.099979 7.062688 0.341823 0.511509 1.071341 7.924466 0.323830 0.490510 1.030484 8.891397 0.310240 0.471109 0.990350 9.976312 0.308966 0.466903 0.980317 10.000000 0.309027 0.466955 0.980405 11.220185 0.304416 0.461068 0.968612 12.589254 0.308516 0.465562 0.977156 14.125375 0.307792 0.466651 0.980589 15.848932 0.309719 0.468732 0.984521 17.782794 0.300664 0.452468 0.949021 19.952623 0.287018 0.430815 0.903019 22.387211 0.269904 0.400671 0.837517 25.000000 0.250139 0.367658 0.766603 28.050461 0.239967 0.347581 0.722094 31.473135 0.230102 0.328636 0.680338 35.313439 0.222737 0.314748 0.649856 39.622330 0.215785 0.299834 0.616462 44.456985 0.209473 0.287825 0.590118 49.881558 0.205335 0.278599 0.569403 55.968028 0.199469 0.267656 0.545524 62.797161 0.193458 0.257352 0.523388 70.459573 0.186947 0.247452 0.502627 79.056942 0.179732 0.237399 0.481952 88.703347 0.171679 0.227620 0.462536 99.526793 0.164067 0.219329 0.446607 100.000000 0.152681 0.204471 0.416539