Peach Bottom (39.76° N, 76.27° E), Control Point Hazard SA (g)

AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.134173e-03 7.460619e-03 1.131271e-02 1.202998e-02 1.215155e-02 0.011955 1.101946e-02 0.001122 3.822672e-03 7.030218e-03 1.103377e-02 1.189104e-02 1.207366e-02 0.011889 1.077455e-02 0.001259 3.523396e-03 6.609252e-03 1.074698e-02 1.172397e-02 1.195693e-02 0.011772 1.044989e-02 0.001413 3.236283e-03 6.190334e-03 1.042771e-02 1.152881e-02 1.180695e-02 0.011610 1.009636e-02 0.001585 2.961203e-03 5.775041e-03 1.007651e-02 1.130155e-02 1.162886e-02 0.011414 9.712272e-03 0.001778 2.698629e-03 5.366531e-03 9.694998e-03 1.104042e-02 1.142145e-02 0.011188 9.300687e-03 0.001995 2.448938e-03 4.966931e-03 9.286627e-03 1.074580e-02 1.118309e-02 0.010933 8.866428e-03 0.002239 2.212278e-03 4.578113e-03 8.853274e-03 1.041688e-02 1.091290e-02 0.010648 8.414994e-03 0.002512 1.988554e-03 4.200978e-03 8.397663e-03 1.005425e-02 1.061065e-02 0.010334 7.950511e-03 0.002818 1.778256e-03 3.837425e-03 7.924084e-03 9.659623e-03 1.027706e-02 0.009992 7.479221e-03 0.003162 1.581534e-03 3.488668e-03 7.437312e-03 9.236445e-03 9.913997e-03 0.009626 7.006313e-03 0.003548 1.398784e-03 3.156122e-03 6.942381e-03 8.788365e-03 9.524070e-03 0.009237 6.537852e-03 0.003981 1.229850e-03 2.840493e-03 6.443877e-03 8.319905e-03 9.110783e-03 0.008830 6.077780e-03 0.004467 1.075036e-03 2.543019e-03 5.947543e-03 7.836274e-03 8.678039e-03 0.008409 5.630818e-03 0.005012 9.339037e-04 2.264029e-03 5.457603e-03 7.342742e-03 8.230385e-03 0.007978 5.199617e-03 0.005623 8.065524e-04 2.004574e-03 4.979923e-03 6.845411e-03 7.772543e-03 0.007542 4.787317e-03 0.006310 6.922609e-04 1.764570e-03 4.517917e-03 6.349553e-03 7.309454e-03 0.007104 4.395313e-03 0.007079 5.911959e-04 1.544645e-03 4.076566e-03 5.860928e-03 6.845813e-03 0.006669 4.025212e-03 0.007943 5.028167e-04 1.344187e-03 3.657915e-03 5.383867e-03 6.386129e-03 0.006241 3.677300e-03 0.008913 4.251690e-04 1.163398e-03 3.265749e-03 4.923203e-03 5.934472e-03 0.005822 3.352075e-03 0.010000 3.573780e-04 1.001216e-03 2.900717e-03 4.481994e-03 5.494444e-03 0.005415 3.049131e-03 0.011220 2.989404e-04 8.572748e-04 2.564847e-03 4.063445e-03 5.069044e-03 0.005023 2.776222e-03 0.012589 2.487998e-04 7.303813e-04 2.257491e-03 3.669182e-03 4.660747e-03 0.004646 2.532258e-03 0.014125 2.062773e-04 6.202363e-04 1.979226e-03 3.300929e-03 4.271398e-03 0.004287 2.308509e-03 0.015849 1.704174e-04 5.241167e-04 1.728249e-03 2.958818e-03 3.902292e-03 0.003946 2.101499e-03 0.017783 1.404961e-04 4.411307e-04 1.504015e-03 2.643365e-03 3.554345e-03 0.003628 1.910339e-03 0.019953 1.154953e-04 3.697890e-04 1.304606e-03 2.354062e-03 3.227928e-03 0.003332 1.734158e-03 0.022387 9.476501e-05 3.089946e-04 1.128753e-03 2.090311e-03 2.923411e-03 0.003057 1.572167e-03 0.025119 7.760838e-05 2.573156e-04 9.736372e-04 1.850983e-03 2.641161e-03 0.002799 1.423484e-03 0.028184 6.348972e-05 2.137174e-04 8.376365e-04 1.635039e-03 2.380737e-03 0.002559 1.287270e-03 0.031623 5.188128e-05 1.770453e-04 7.186767e-04 1.440604e-03 2.141036e-03 0.002334 1.162679e-03 0.035481 4.237018e-05 1.464379e-04 6.151095e-04 1.266204e-03 1.920880e-03 0.002125 1.048859e-03 0.039811 3.458165e-05 1.208489e-04 5.250968e-04 1.110216e-03 1.719294e-03 0.001931 9.449515e-04 0.044668 2.821587e-05 9.955107e-05 4.471750e-04 9.711918e-04 1.535314e-03 0.001751 8.501289e-04 0.050119 2.301312e-05 8.184417e-05 3.798180e-04 8.475772e-04 1.367927e-03 0.001585 7.636256e-04 0.056234 1.876308e-05 6.717643e-05 3.218034e-04 7.379959e-04 1.216086e-03 0.001432 6.847533e-04 0.063096 1.529148e-05 5.503564e-05 2.719237e-04 6.410520e-04 1.078730e-03 0.001292 6.129918e-04 0.070795 1.245551e-05 4.501452e-05 2.291929e-04 5.555048e-04 9.547953e-04 0.001163 5.477422e-04 0.079433 1.013878e-05 3.674880e-05 1.926069e-04 4.801475e-04 8.432368e-04 0.001045 4.875274e-04 0.089125 8.245795e-06 2.994847e-05 1.613938e-04 4.139318e-04 7.430444e-04 0.000937 4.322622e-04 0.100000 6.699332e-06 2.435786e-05 1.348038e-04 3.558496e-04 6.532671e-04 0.000839 3.820881e-04 0.112202 5.436050e-06 1.977297e-05 1.122324e-04 3.049852e-04 5.729924e-04 0.000750 3.367714e-04 0.125893 4.404200e-06 1.601522e-05 9.310704e-05 2.605457e-04 5.012951e-04 0.000668 2.959334e-04 0.141254 3.562023e-06 1.294367e-05 7.697255e-05 2.218297e-04 4.373107e-04 0.000594 2.591715e-04 0.158489 2.874717e-06 1.043415e-05 6.337937e-05 1.881632e-04 3.803173e-04 0.000527 2.260522e-04

0.177828 2.314621e-06 8.389779e-06 5.198581e-05 1.589798e-04 3.297011e-04 0.000466 1.961139e-04 0.199526 1.858605e-06 6.726195e-06 4.245851e-05 1.337605e-04 2.848916e-04 0.000410 1.692982e-04 0.223872 1.488090e-06 5.376612e-06 3.453445e-05 1.120502e-04 2.453187e-04 0.000360 1.454651e-04 0.251189 1.187196e-06 4.282505e-06 2.795529e-05 9.341433e-05 2.104481e-04 0.000314 1.244220e-04 0.281838 9.436369e-07 3.398693e-06 2.252587e-05 7.748951e-05 1.798019e-04 0.000274 1.059141e-04 0.316228 7.467699e-07 2.685870e-06 1.805800e-05 6.393512e-05 1.529554e-04 0.000238 8.970355e-05 0.354813 5.883413e-07 2.113525e-06 1.440545e-05 5.246000e-05 1.295223e-04 0.000206 7.552936e-05 0.398107 4.610359e-07 1.654677e-06 1.142709e-05 4.278861e-05 1.091464e-04 0.000177 6.317135e-05 0.446684 3.593618e-07 1.288927e-06 9.015941e-06 3.468719e-05 9.149768e-05 0.000152 5.248943e-05 0.501187 2.783090e-07 9.979153e-07 7.069234e-06 2.793414e-05 7.627678e-05 0.000130 4.332210e-05 0.562341 2.142057e-07 7.680577e-07 5.510021e-06 2.234450e-05 6.321151e-05 0.000110 3.549251e-05 0.630957 1.636255e-07 5.869077e-07 4.264560e-06 1.774326e-05 5.205403e-05 0.000093 2.884363e-05 0.707946 1.241010e-07 4.454198e-07 3.278421e-06 1.398471e-05 4.257720e-05 0.000078 2.325042e-05 0.794328 9.329813e-08 3.351791e-07 2.499914e-06 1.093262e-05 3.457478e-05 0.000065 1.857425e-05 0.891251 6.957173e-08 2.502154e-07 1.891380e-06 8.475266e-06 2.785907e-05 0.000054 1.470245e-05 1.000000 5.135218e-08 1.849342e-07 1.417368e-06 6.509414e-06 2.226047e-05 0.000045 1.152036e-05 1.122019 3.754634e-08 1.354065e-07 1.052226e-06 4.951114e-06 1.762582e-05 0.000037 8.932974e-06 1.258925 2.711995e-08 9.795789e-08 7.720560e-07 3.724483e-06 1.381771e-05 0.000030 6.850715e-06 1.412538 1.936712e-08 7.006352e-08 5.599099e-07 2.768632e-06 1.071291e-05 0.000024 5.194107e-06 1.584893 1.361881e-08 4.934645e-08 3.998582e-07 2.029089e-06 8.201801e-06 0.000019 3.886205e-06 1.778279 9.429132e-09 3.421531e-08 2.809762e-07 1.463244e-06 6.188373e-06 0.000015 2.867117e-06 1.995262 6.390416e-09 2.322184e-08 1.932018e-07 1.034135e-06 4.588854e-06 0.000012 2.081544e-06 2.238721 4.225449e-09 1.537395e-08 1.294477e-07 7.125496e-07 3.330041e-06 0.000009 1.483419e-06 2.511886 2.688169e-09 9.791214e-09 8.335053e-08 4.735336e-07 2.348981e-06 0.000007 1.033949e-06 2.818383 1.617958e-09 5.897359e-09 5.065443e-08 2.983186e-07 1.592073e-06 0.000005 7.007907e-07 3.162278 9.886908e-10 3.601458e-09 3.089315e-08 1.877875e-07 1.083089e-06 0.000004 4.907621e-07 3.548134 3.594232e-10 1.305557e-09 1.113186e-08 7.725647e-08 5.741037e-07 0.000002 2.807334e-07 Peach Bottom (39.76° N, 76.27° E), Response Spectra Frequency (Hz)

UHRS 1E-4 (g)

GMRS (g)

UHRS 1E-5 (g) 0.500000 0.021698 0.036991 0.080045 0.561009 0.025065 0.043122 0.093524 0.629463 0.028608 0.049282 0.106917 0.706269 0.032316 0.055511 0.120346 0.792447 0.036191 0.061849 0.133915 0.889140 0.040235 0.068326 0.147705 0.997631 0.044460 0.074974 0.161793 1.000000 0.044549 0.075113 0.162086 1.122019 0.051997 0.090127 0.195832 1.258925 0.060146 0.105208 0.229123 1.412538 0.068923 0.120342 0.261963 1.584893 0.078275 0.135596 0.294587 1.778279 0.088168 0.151013 0.327153 1.995262 0.098579 0.166667 0.359897 2.238721 0.109506 0.182559 0.392831 2.500000 0.120472 0.198082 0.424761 2.805046 0.135777 0.226815 0.488310

3.147313 0.152865 0.256539 0.552938 3.531344 0.171890 0.287403 0.618890 3.962233 0.192850 0.319458 0.686315 4.445698 0.215722 0.352747 0.755381 4.988156 0.240588 0.387628 0.827011 5.000000 0.241124 0.388362 0.828509 5.610092 0.262472 0.428131 0.916245 6.294627 0.287182 0.471902 1.011781 7.062688 0.315417 0.519473 1.114404 7.924466 0.347004 0.570143 1.222382 8.891397 0.382055 0.623746 1.335178 9.976312 0.420678 0.680256 1.452661 10.000000 0.421513 0.681438 1.455095 11.220185 0.435407 0.706945 1.511191 12.589254 0.451019 0.735744 1.574601 14.125375 0.469139 0.768286 1.645847 15.848932 0.491275 0.807386 1.731136 17.782794 0.519993 0.857231 1.839433 19.952623 0.556867 0.920463 1.976428 22.387211 0.601169 0.994367 2.135478 25.000000 0.633386 1.047148 2.248557 28.050461 0.663453 1.095984 2.352956 31.473135 0.691257 1.142398 2.452861 35.313439 0.711076 1.175645 2.524510 39.622330 0.715242 1.182779 2.539961 44.456985 0.707259 1.169577 2.511611 49.881558 0.680215 1.124849 2.415556 55.968028 0.631984 1.047648 2.251148 62.797161 0.567315 0.943889 2.030047 70.459573 0.495385 0.826383 1.778494 79.056942 0.423924 0.710388 1.530590 88.703347 0.368313 0.615278 1.324635 99.526793 0.323884 0.543897 1.172490 100.000000 0.293288 0.494159 1.066155