Grand Gulf (32.01° N, 91.05° E), Control Point Hazard SA (g)

AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.839123e-03 7.033186e-03 9.896540e-03 1.048607e-02 1.055807e-02 1.038648e-02 9.532864e-03 0.001122 4.838900e-03 7.033177e-03 9.895793e-03 1.047867e-02 1.051486e-02 1.037434e-02 9.532863e-03 0.001259 4.837893e-03 7.033058e-03 9.892706e-03 1.045718e-02 1.044618e-02 1.032610e-02 9.532774e-03 0.001413 4.834328e-03 7.032006e-03 9.882129e-03 1.041197e-02 1.034578e-02 1.022731e-02 9.528753e-03 0.001585 4.824194e-03 7.025828e-03 9.852390e-03 1.033792e-02 1.021473e-02 1.008226e-02 9.486529e-03 0.001778 4.800512e-03 7.001276e-03 9.784968e-03 1.023356e-02 1.005678e-02 9.909492e-03 9.338598e-03 0.001995 4.753984e-03 6.933603e-03 9.662808e-03 1.009815e-02 9.874556e-03 9.714980e-03 9.089557e-03 0.002239 4.675860e-03 6.799132e-03 9.482580e-03 9.932121e-03 9.668820e-03 9.498038e-03 8.802246e-03 0.002512 4.562577e-03 6.595654e-03 9.255338e-03 9.737339e-03 9.439676e-03 9.258991e-03 8.495127e-03 0.002818 4.419044e-03 6.344314e-03 8.995125e-03 9.515992e-03 9.187573e-03 8.998721e-03 8.169964e-03 0.003162 4.256736e-03 6.071536e-03 8.711132e-03 9.269828e-03 8.913542e-03 8.718448e-03 7.830084e-03 0.003548 4.087590e-03 5.795064e-03 8.408192e-03 9.000304e-03 8.619149e-03 8.419975e-03 7.479227e-03 0.003981 3.919308e-03 5.523166e-03 8.089436e-03 8.709022e-03 8.306580e-03 8.105732e-03 7.120871e-03 0.004467 3.754995e-03 5.258957e-03 7.757699e-03 8.397986e-03 7.978435e-03 7.778446e-03 6.758549e-03 0.005012 3.595108e-03 5.003566e-03 7.415972e-03 8.069682e-03 7.637678e-03 7.441033e-03 6.395910e-03 0.005623 3.439084e-03 4.757434e-03 7.067466e-03 7.727039e-03 7.287435e-03 7.096367e-03 6.036217e-03 0.006310 3.286042e-03 4.520678e-03 6.715526e-03 7.373326e-03 6.930881e-03 6.747337e-03 5.682133e-03 0.007079 3.134980e-03 4.293155e-03 6.363465e-03 7.012004e-03 6.571076e-03 6.396563e-03 5.335559e-03 0.007943 2.984838e-03 4.074461e-03 6.014420e-03 6.646551e-03 6.210818e-03 6.046427e-03 4.997743e-03 0.008913 2.834543e-03 3.863919e-03 5.671230e-03 6.280282e-03 5.852546e-03 5.698837e-03 4.669106e-03 0.010000 2.683082e-03 3.660583e-03 5.336313e-03 5.916185e-03 5.498176e-03 5.355319e-03 4.349524e-03 0.011220 2.529580e-03 3.463250e-03 5.011552e-03 5.556775e-03 5.149165e-03 5.016971e-03 4.038279e-03 0.012589 2.373375e-03 3.270495e-03 4.698185e-03 5.203977e-03 4.806448e-03 4.684534e-03 3.734440e-03 0.014125 2.214093e-03 3.080746e-03 4.396737e-03 4.859071e-03 4.470527e-03 4.358246e-03 3.436851e-03 0.015849 2.051727e-03 2.892393e-03 4.107003e-03 4.522705e-03 4.141598e-03 4.032803e-03 3.139130e-03 0.017783 1.886721e-03 2.703946e-03 3.828093e-03 4.194971e-03 3.819085e-03 3.682206e-03 2.817058e-03 0.019953 1.720017e-03 2.514221e-03 3.558559e-03 3.875561e-03 3.498422e-03 3.288954e-03 2.459523e-03 0.022387 1.553056e-03 2.322517e-03 3.296597e-03 3.563960e-03 3.174750e-03 2.870693e-03 2.096730e-03 0.025119 1.387712e-03 2.128698e-03 3.040311e-03 3.259472e-03 2.851707e-03 2.458887e-03 1.754386e-03 0.028184 1.226145e-03 1.933159e-03 2.788006e-03 2.961156e-03 2.533645e-03 2.074331e-03 1.441825e-03 0.031623 1.070621e-03 1.736907e-03 2.538458e-03 2.668390e-03 2.225073e-03 1.724031e-03 1.164098e-03 0.035481 9.233248e-04 1.541815e-03 2.291124e-03 2.382107e-03 1.931610e-03 1.411544e-03 9.238930e-04 0.039811 7.861804e-04 1.350632e-03 2.046353e-03 2.104896e-03 1.657926e-03 1.138752e-03 7.215579e-04 0.044668 6.607053e-04 1.166546e-03 1.805665e-03 1.839865e-03 1.407097e-03 9.056853e-04 5.553361e-04 0.050119 5.479145e-04 9.926499e-04 1.571833e-03 1.589987e-03 1.180872e-03 7.109768e-04 4.218084e-04 0.056234 4.483023e-04 8.316368e-04 1.348445e-03 1.357959e-03 9.800018e-04 5.526317e-04 3.165686e-04 0.063096 3.618734e-04 6.856554e-04 1.139178e-03 1.145976e-03 8.044593e-04 4.262761e-04 2.349486e-04 0.070795 2.881905e-04 5.561595e-04 9.472097e-04 9.555115e-04 6.535900e-04 3.264264e-04 1.724004e-04 0.079433 2.264453e-04 4.437784e-04 7.748903e-04 7.872237e-04 5.260173e-04 2.490530e-04 1.250593e-04 0.089125 1.755669e-04 3.483209e-04 6.235933e-04 6.409836e-04 4.195695e-04 1.893999e-04 8.994655e-05 0.100000 1.343377e-04 2.689236e-04 4.936710e-04 5.159646e-04 3.318003e-04 1.435427e-04 6.445879e-05 0.112202 1.014785e-04 2.042352e-04 3.845122e-04 4.107711e-04 2.603655e-04 1.088167e-04 4.616414e-05 0.125893 7.570736e-05 1.525863e-04 2.947119e-04 3.236026e-04 2.028946e-04 8.259595e-05 3.311896e-05 0.141254 5.579723e-05 1.121614e-04 2.223306e-04 2.524186e-04 1.570502e-04 6.264385e-05 2.384851e-05 0.158489 4.063345e-05 8.114342e-05 1.651543e-04 1.950749e-04 1.207912e-04 4.744775e-05 1.725516e-05

0.177828 2.924766e-05 5.780312e-05 1.208837e-04 1.494430e-04 9.238409e-05 3.590720e-05 1.254718e-05 0.199526 2.082000e-05 4.056349e-05 8.726995e-05 1.135323e-04 7.029150e-05 2.718263e-05 9.162802e-06 0.223872 1.466574e-05 2.805447e-05 6.222468e-05 8.558023e-05 5.320681e-05 2.060891e-05 6.707841e-06 0.251189 1.022527e-05 1.913572e-05 4.389435e-05 6.406636e-05 4.009918e-05 1.564363e-05 4.912077e-06 0.281838 7.056146e-06 1.288292e-05 3.069635e-05 4.768039e-05 3.014044e-05 1.188429e-05 3.589365e-06 0.316228 4.818424e-06 8.567233e-06 2.132846e-05 3.530855e-05 2.262722e-05 9.034296e-06 2.610598e-06 0.354813 3.255599e-06 5.634847e-06 1.475831e-05 2.603706e-05 1.697648e-05 6.861958e-06 1.884617e-06 0.398107 2.177050e-06 3.675481e-06 1.019491e-05 1.913692e-05 1.272884e-05 5.192352e-06 1.346282e-06 0.446684 1.442687e-06 2.388446e-06 7.048888e-06 1.403036e-05 9.540216e-06 3.908380e-06 9.496778e-07 0.501187 9.497796e-07 1.555304e-06 4.889904e-06 1.026482e-05 7.146966e-06 2.925888e-06 6.599584e-07 0.562341 6.233467e-07 1.020265e-06 3.409601e-06 7.494192e-06 5.343681e-06 2.173799e-06 4.506773e-07 0.630957 4.094926e-07 6.770861e-07 2.391871e-06 5.459154e-06 3.981046e-06 1.596635e-06 3.020066e-07 0.707946 2.704127e-07 4.561008e-07 1.688234e-06 3.966136e-06 2.951094e-06 1.154830e-06 1.979098e-07 0.794328 1.804815e-07 3.122620e-07 1.198042e-06 2.870131e-06 2.173907e-06 8.177355e-07 1.263951e-07 0.891251 1.223494e-07 2.170265e-07 8.535229e-07 2.064862e-06 1.588302e-06 5.653487e-07 7.835468e-08 1.000000 8.422954e-08 1.526018e-07 6.090789e-07 1.474535e-06 1.146327e-06 3.809952e-07 4.686046e-08 1.122019 5.872414e-08 1.080045e-07 4.342023e-07 1.044530e-06 8.149345e-07 2.475597e-07 2.684937e-08 1.258925 4.141868e-08 7.641870e-08 3.085083e-07 7.337802e-07 5.703270e-07 1.528776e-07 1.465259e-08 1.412538 2.954935e-08 5.353352e-08 2.179261e-07 5.106158e-07 3.923325e-07 8.850474e-08 7.527387e-09 1.584893 2.129998e-08 3.694123e-08 1.523741e-07 3.506905e-07 2.648722e-07 4.740122e-08 3.533247e-09 1.778279 1.546714e-08 2.524505e-08 1.047199e-07 2.360645e-07 1.754265e-07 2.277714e-08 1.482738e-09 1.995262 1.127357e-08 1.719771e-08 7.013766e-08 1.546288e-07 1.130848e-07 9.141587e-09 5.294976e-10 2.238721 8.225339e-09 1.172432e-08 4.545707e-08 9.837501e-08 6.924373e-08 2.742729e-09 1.378115e-10 2.511886 5.993673e-09 8.024464e-09 2.848677e-08 6.110908e-08 3.870172e-08 5.481594e-10 2.133759e-11 2.818383 4.350526e-09 5.520720e-09 1.739324e-08 3.728785e-08 1.881183e-08 6.676119e-11 1.670160e-12 3.162278 3.138182e-09 3.811274e-09 1.046280e-08 2.223277e-08 7.569424e-09 4.666039e-12 5.955080e-14 3.548134 2.245908e-09 2.630296e-09 6.254260e-09 1.270422e-08 2.436105e-09 1.798394e-13 9.095849e-16 3.981072 1.592888e-09 1.805313e-09 3.730024e-09 6.803243e-09 6.166904e-10 3.720679e-15 5.744410e-18 4.466836 1.118514e-09 1.225831e-09 2.218861e-09 3.359511e-09 1.205065e-10 4.055574e-17 1.470179e-20 5.011872 7.768808e-10 8.204146e-10 1.312212e-09 1.508943e-09 1.763500e-11 2.299263e-19 1.545955e-23 5.623413 5.689810e-10 5.841310e-10 8.740656e-10 8.577958e-10 8.887453e-12 1.149635e-19 7.729774e-24 6.309573 3.610813e-10 3.478474e-10 4.359197e-10 2.066488e-10 1.399024e-13 7.866330e-25 0.000000e+00 Grand Gulf (32.01° N, 91.05° E), Response Spectra Frequency (Hz)

UHRS 1E-4 (g)

GMRS (g)

UHRS 1E-5 (g) 0.500000 0.112851 0.129138 0.252931 0.561009 0.118358 0.132895 0.259058 0.629463 0.120446 0.133699 0.259881 0.706269 0.126871 0.140074 0.271905 0.792447 0.134439 0.147155 0.285035 0.889140 0.139550 0.150787 0.291127 0.997631 0.146971 0.157080 0.302451 1.000000 0.147139 0.157230 0.302724 1.122019 0.155114 0.166616 0.321214 1.258925 0.160025 0.172587 0.333060 1.412538 0.165648 0.179187 0.346056 1.584893 0.172621 0.186870 0.360962

1.778279 0.177273 0.192106 0.371172 1.995262 0.180687 0.196801 0.380726 2.238721 0.186636 0.202711 0.391886 2.500000 0.190154 0.207045 0.400512 2.805046 0.190145 0.214013 0.417435 3.147313 0.194387 0.223001 0.437047 3.531344 0.197407 0.229687 0.451742 3.962233 0.200882 0.236377 0.466211 4.445698 0.207724 0.248060 0.491060 4.988156 0.210113 0.254663 0.506004 5.000000 0.210086 0.254692 0.506093 5.610092 0.202088 0.246631 0.490890 6.294627 0.192434 0.238392 0.476273 7.062688 0.191064 0.239554 0.480032 7.924466 0.184277 0.231551 0.464250 8.891397 0.176054 0.222485 0.446710 9.976312 0.171913 0.218135 0.438421 10.000000 0.171881 0.218106 0.438367 11.220185 0.161956 0.206252 0.414915 12.589254 0.150703 0.193370 0.389732 14.125375 0.144529 0.185876 0.374844 15.848932 0.137574 0.177953 0.359384 17.782794 0.130147 0.169037 0.341727 19.952623 0.122574 0.158695 0.320565 22.387211 0.116231 0.150107 0.303026 25.000000 0.113066 0.143328 0.287999 28.050461 0.110694 0.137979 0.276086 31.473135 0.108728 0.133232 0.265452 35.313439 0.107299 0.129413 0.256822 39.622330 0.106232 0.126130 0.249327 44.456985 0.105997 0.124274 0.244885 49.881558 0.105799 0.122577 0.240825 55.968028 0.105324 0.120867 0.236900 62.797161 0.104193 0.118731 0.232304 70.459573 0.102354 0.116195 0.227128 79.056942 0.099503 0.112912 0.220686 88.703347 0.095717 0.109089 0.213448 99.526793 0.091876 0.105552 0.206938 100.000000 0.085887 0.098585 0.193238