Indian Point (41.27° N, 73.94° E), Control Point Hazard SA (g)
AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.188740e-03 7.540561e-03 1.136690e-02 1.205592e-02 1.216531e-02 1.194383e-02 1.101536e-02 0.001122 3.875126e-03 7.107806e-03 1.108728e-02 1.189618e-02 1.203505e-02 1.177856e-02 1.068703e-02 0.001259 3.573723e-03 6.686499e-03 1.080681e-02 1.173292e-02 1.190063e-02 1.160863e-02 1.035745e-02 0.001413 3.284555e-03 6.267124e-03 1.049375e-02 1.153882e-02 1.173867e-02 1.140997e-02 9.995284e-03 0.001585 3.007328e-03 5.850691e-03 1.014867e-02 1.131303e-02 1.154802e-02 1.118188e-02 9.602267e-03 0.001778 2.742545e-03 5.440686e-03 9.772462e-03 1.105233e-02 1.132537e-02 1.092263e-02 9.182999e-03 0.001995 2.490574e-03 5.039116e-03 9.369046e-03 1.075891e-02 1.107221e-02 1.063431e-02 8.742366e-03 0.002239 2.251713e-03 4.648281e-03 8.940258e-03 1.043069e-02 1.078617e-02 1.031654e-02 8.286398e-03 0.002512 2.025658e-03 4.268695e-03 8.488387e-03 1.006877e-02 1.046790e-02 9.970589e-03 7.818077e-03 0.002818 1.813051e-03 3.902530e-03 8.017709e-03 9.674319e-03 1.011801e-02 9.599094e-03 7.345251e-03 0.003162 1.613881e-03 3.550797e-03 7.532723e-03 9.251236e-03 9.739686e-03 9.205509e-03 6.871834e-03 0.003548 1.428781e-03 3.215248e-03 7.038918e-03 8.803176e-03 9.335829e-03 8.794232e-03 6.405063e-03 0.003981 1.257356e-03 2.896257e-03 6.540151e-03 8.334154e-03 8.909826e-03 8.368524e-03 5.947271e-03 0.004467 1.100207e-03 2.595487e-03 6.043050e-03 7.850315e-03 8.466837e-03 7.934081e-03 5.504409e-03 0.005012 9.566282e-04 2.312856e-03 5.550843e-03 7.355676e-03 8.010373e-03 7.493877e-03 5.077575e-03 0.005623 8.270299e-04 2.049906e-03 5.070561e-03 6.857905e-03 7.546952e-03 7.053899e-03 4.670928e-03 0.006310 7.104443e-04 1.806130e-03 4.604576e-03 6.360644e-03 7.079889e-03 6.616602e-03 4.284588e-03 0.007079 6.074104e-04 1.582681e-03 4.159189e-03 5.871491e-03 6.615662e-03 6.187163e-03 3.920898e-03 0.007943 5.170438e-04 1.378508e-03 3.735365e-03 5.392926e-03 6.156722e-03 5.767138e-03 3.579188e-03 0.008913 4.373793e-04 1.194313e-03 3.338181e-03 4.931664e-03 5.708862e-03 5.360612e-03 3.260518e-03 0.010000 3.675623e-04 1.028662e-03 2.967391e-03 4.489080e-03 5.273726e-03 4.968426e-03 2.963812e-03 0.011220 3.073240e-04 8.816140e-04 2.626132e-03 4.069984e-03 4.855570e-03 4.593217e-03 2.702732e-03 0.012589 2.555087e-04 7.516436e-04 2.312977e-03 3.674500e-03 4.455096e-03 4.235155e-03 2.454531e-03 0.014125 2.115567e-04 6.386880e-04 2.029456e-03 3.305827e-03 4.075340e-03 3.895909e-03 2.222688e-03 0.015849 1.745347e-04 5.397775e-04 1.773148e-03 2.962764e-03 3.715872e-03 3.575516e-03 2.007782e-03 0.017783 1.437743e-04 4.543119e-04 1.544083e-03 2.646870e-03 3.378506e-03 3.274215e-03 1.810196e-03 0.019953 1.180592e-04 3.806906e-04 1.339911e-03 2.356862e-03 3.062850e-03 2.991425e-03 1.629018e-03 0.022387 9.675292e-05 3.179567e-04 1.159551e-03 2.092811e-03 2.769495e-03 2.727255e-03 1.463611e-03 0.025119 7.915779e-05 2.645667e-04 1.000255e-03 1.852639e-03 2.497182e-03 2.480729e-03 1.312723e-03 0.028184 6.470820e-05 2.195391e-04 8.605955e-04 1.635800e-03 2.246002e-03 2.251746e-03 1.175643e-03 0.031623 5.283122e-05 1.816697e-04 7.383320e-04 1.440387e-03 2.014799e-03 2.039441e-03 1.051452e-03 0.035481 4.310729e-05 1.501639e-04 6.319117e-04 1.265346e-03 1.803180e-03 1.843441e-03 9.393425e-04 0.039811 3.515213e-05 1.238182e-04 5.393677e-04 1.108737e-03 1.609771e-03 1.662735e-03 8.382017e-04 0.044668 2.866253e-05 1.019042e-04 4.592793e-04 9.693378e-04 1.433925e-03 1.496813e-03 7.470189e-04 0.050119 2.336154e-05 8.369306e-05 3.900239e-04 8.453723e-04 1.274241e-03 1.344639e-03 6.647546e-04 0.056234 1.903549e-05 6.865484e-05 3.303961e-04 7.356115e-04 1.129914e-03 1.205606e-03 5.905877e-04 0.063096 1.550524e-05 5.621004e-05 2.791261e-04 6.385107e-04 9.996097e-04 1.078718e-03 5.246569e-04 0.070795 1.262343e-05 4.594442e-05 2.352337e-04 5.529225e-04 8.824357e-04 9.632900e-04 4.649712e-04 0.079433 1.027101e-05 3.748035e-05 1.976428e-04 4.775355e-04 7.771595e-04 8.583829e-04 4.110544e-04 0.089125 8.350426e-06 3.052592e-05 1.655842e-04 4.113669e-04 6.829036e-04 7.633120e-04 3.624382e-04 0.100000 6.782133e-06 2.481459e-05 1.382688e-04 3.533473e-04 5.985897e-04 6.772388e-04 3.186526e-04 0.112202 5.501494e-06 2.013334e-05 1.151132e-04 3.026195e-04 5.234009e-04 5.995346e-04 2.793103e-04 0.125893 4.456100e-06 1.629956e-05 9.548988e-05 2.583092e-04 4.564142e-04 5.294062e-04 2.440587e-04 0.141254 3.603224e-06 1.316838e-05 7.894205e-05 2.197561e-04 3.969084e-04 4.660850e-04 2.125701e-04 0.158489 2.907403e-06 1.061140e-05 6.499532e-05 1.862321e-04 3.440691e-04 4.091542e-04 1.842666e-04
0.177828 2.340561e-06 8.529667e-06 5.330870e-05 1.572190e-04 2.973127e-04 3.581179e-04 1.589774e-04 0.199526 1.879158e-06 6.836682e-06 4.353882e-05 1.321566e-04 2.560135e-04 3.124542e-04 1.365702e-04 0.223872 1.504386e-06 5.463864e-06 3.541640e-05 1.106154e-04 2.196636e-04 2.717141e-04 1.167977e-04 0.251189 1.200081e-06 4.351047e-06 2.866921e-05 9.211920e-05 1.876934e-04 2.354083e-04 9.940859e-05 0.281838 9.538187e-07 3.452688e-06 2.310472e-05 7.634047e-05 1.597035e-04 2.031483e-04 8.418303e-05 0.316228 7.547816e-07 2.728206e-06 1.852324e-05 6.291241e-05 1.352494e-04 1.745687e-04 7.089756e-05 0.354813 5.946602e-07 2.146728e-06 1.477966e-05 5.156818e-05 1.139986e-04 1.493599e-04 5.933235e-05 0.398107 4.659984e-07 1.680564e-06 1.172540e-05 4.200494e-05 9.556842e-05 1.271754e-04 4.932085e-05 0.446684 3.632683e-07 1.309114e-06 9.254083e-06 3.401379e-05 7.968869e-05 1.077515e-04 4.072705e-05 0.501187 2.813653e-07 1.013528e-06 7.257393e-06 2.735068e-05 6.603561e-05 9.078886e-05 3.339440e-05 0.562341 2.166024e-07 7.801356e-07 5.658542e-06 2.185063e-05 5.438887e-05 7.606070e-05 2.717172e-05 0.630957 1.654897e-07 5.961529e-07 4.380715e-06 1.732180e-05 4.447899e-05 6.331514e-05 2.192957e-05 0.707946 1.255548e-07 4.524962e-07 3.369216e-06 1.363369e-05 3.612257e-05 5.236149e-05 1.755018e-05 0.794328 9.441806e-08 3.405365e-07 2.570039e-06 1.063753e-05 2.909480e-05 4.297875e-05 1.392017e-05 0.891251 7.043365e-08 2.542750e-07 1.945503e-06 8.233138e-06 2.324642e-05 3.500588e-05 1.093675e-05 1.000000 5.200539e-08 1.879709e-07 1.458573e-06 6.309158e-06 1.839477e-05 2.825866e-05 8.506349e-06 1.122019 3.804093e-08 1.376803e-07 1.083571e-06 4.789563e-06 1.441662e-05 2.259914e-05 6.546337e-06 1.258925 2.748773e-08 9.963407e-08 7.955082e-07 3.592896e-06 1.116565e-05 1.787342e-05 4.982011e-06 1.412538 1.964056e-08 7.130145e-08 5.774512e-07 2.664384e-06 8.544941e-06 1.396856e-05 3.745946e-06 1.584893 1.381817e-08 5.024607e-08 4.127332e-07 1.945602e-06 6.437952e-06 1.075578e-05 2.778702e-06 1.778279 9.574140e-09 3.487085e-08 2.903829e-07 1.398084e-06 4.769422e-06 8.143476e-06 2.030204e-06 1.995262 6.493734e-09 2.368983e-08 1.998985e-07 9.829211e-07 3.454720e-06 6.032925e-06 1.457717e-06 2.238721 4.299037e-09 1.570793e-08 1.341958e-07 6.733858e-07 2.434953e-06 4.348913e-06 1.025145e-06 2.511886 2.739412e-09 1.002423e-08 8.661935e-08 4.432736e-07 1.646553e-06 3.012205e-06 7.021916e-07 2.818383 1.653572e-09 6.059601e-09 5.289020e-08 2.754662e-07 1.047828e-06 1.965948e-06 4.640542e-07 3.162278 1.016435e-09 3.727982e-09 3.261875e-08 1.703349e-07 6.500909e-07 1.241016e-06 3.146384e-07 3.548134 3.792982e-10 1.396363e-09 1.234731e-08 6.520362e-08 2.523534e-07 5.160836e-07 1.652226e-07 Indian Point (41.27° N, 73.94° E), Response Spectra Frequency (Hz)
UHRS 1E-4 (g)
GMRS (g)
UHRS 1E-5 (g) 0.500000 0.021964 0.037296 0.080623 0.561009 0.025374 0.043481 0.094209 0.629463 0.028967 0.049702 0.107721 0.706269 0.032728 0.055998 0.121281 0.792447 0.036664 0.062411 0.134998 0.889140 0.040774 0.068972 0.148954 0.997631 0.045074 0.075714 0.163229 1.000000 0.045164 0.075854 0.163526 1.122019 0.052721 0.091044 0.197642 1.258925 0.060995 0.106307 0.231307 1.412538 0.069917 0.121656 0.264596 1.584893 0.079427 0.137141 0.297699 1.778279 0.089491 0.152809 0.330790 1.995262 0.100090 0.168727 0.364077 2.238721 0.111216 0.184934 0.397685 2.500000 0.122364 0.200716 0.430154 2.805046 0.137885 0.229804 0.494457
3.147313 0.155026 0.259549 0.559091 3.531344 0.173741 0.289730 0.623488 3.962233 0.193941 0.320391 0.687849 4.445698 0.215572 0.351479 0.752118 4.988156 0.238544 0.383101 0.816696 5.000000 0.239032 0.383754 0.818018 5.610092 0.257589 0.418626 0.895079 6.294627 0.278398 0.455249 0.974891 7.062688 0.301441 0.493710 1.057670 7.924466 0.327038 0.534038 1.143212 8.891397 0.355279 0.575712 1.230058 9.976312 0.385835 0.618637 1.318274 10.000000 0.386499 0.619538 1.320105 11.220185 0.394057 0.633860 1.351802 12.589254 0.402530 0.649811 1.387061 14.125375 0.412034 0.667260 1.425432 15.848932 0.422931 0.686238 1.466686 17.782794 0.435844 0.708271 1.514356 19.952623 0.451408 0.734438 1.570771 22.387211 0.469670 0.763808 1.633403 25.000000 0.478725 0.777808 1.662952 28.050461 0.486709 0.790785 1.690700 31.473135 0.493047 0.801915 1.714942 35.313439 0.496666 0.809556 1.732222 39.622330 0.495295 0.810051 1.734745 44.456985 0.489752 0.804009 1.723428 49.881558 0.476810 0.786496 1.687895 55.968028 0.454143 0.753625 1.619784 62.797161 0.422893 0.706384 1.520736 70.459573 0.386218 0.649554 1.400785 79.056942 0.347183 0.587061 1.267725 88.703347 0.309166 0.525495 1.136248 99.526793 0.276313 0.472140 1.022231 100.000000 0.250127 0.428583 0.928571