Point Beach (44.28° N, 87.54° E), Control Point Hazard SA (g)

AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 3.138537e-03 4.371977e-03 5.977988e-03 6.291965e-03 6.344719e-03 6.246274e-03 5.804481e-03 0.001122 3.094400e-03 4.358599e-03 5.976868e-03 6.290202e-03 6.344719e-03 6.246274e-03 5.804481e-03 0.001259 3.012095e-03 4.303022e-03 5.966516e-03 6.286634e-03 6.344719e-03 6.246273e-03 5.804480e-03 0.001413 2.909919e-03 4.219048e-03 5.922693e-03 6.280136e-03 6.344712e-03 6.246255e-03 5.804445e-03 0.001585 2.805808e-03 4.110552e-03 5.842311e-03 6.269376e-03 6.344615e-03 6.245965e-03 5.803915e-03 0.001778 2.702665e-03 3.986526e-03 5.736425e-03 6.252984e-03 6.343803e-03 6.243511e-03 5.799851e-03 0.001995 2.599812e-03 3.846717e-03 5.610985e-03 6.229683e-03 6.339725e-03 6.231967e-03 5.782488e-03 0.002239 2.495791e-03 3.694273e-03 5.468368e-03 6.198311e-03 6.326553e-03 6.198561e-03 5.733962e-03 0.002512 2.389682e-03 3.537753e-03 5.310384e-03 6.157662e-03 6.296723e-03 6.134341e-03 5.635791e-03 0.002818 2.279927e-03 3.381876e-03 5.138652e-03 6.106142e-03 6.246095e-03 6.045532e-03 5.487138e-03 0.003162 2.165863e-03 3.227172e-03 4.954156e-03 6.041419e-03 6.176639e-03 5.938933e-03 5.303597e-03 0.003548 2.046439e-03 3.073233e-03 4.757378e-03 5.960614e-03 6.090780e-03 5.813768e-03 5.096426e-03 0.003981 1.921497e-03 2.919062e-03 4.548773e-03 5.861316e-03 5.987825e-03 5.668322e-03 4.868623e-03 0.004467 1.790835e-03 2.763902e-03 4.328649e-03 5.742529e-03 5.865995e-03 5.501668e-03 4.621517e-03 0.005012 1.655034e-03 2.606585e-03 4.097402e-03 5.604462e-03 5.723730e-03 5.313269e-03 4.357117e-03 0.005623 1.515073e-03 2.446490e-03 3.855422e-03 5.447610e-03 5.559775e-03 5.103213e-03 4.078053e-03 0.006310 1.372431e-03 2.282892e-03 3.603430e-03 5.272305e-03 5.373375e-03 4.872576e-03 3.787658e-03 0.007079 1.229199e-03 2.115804e-03 3.342530e-03 5.078880e-03 5.164536e-03 4.623456e-03 3.489981e-03 0.007943 1.088027e-03 1.945480e-03 3.074439e-03 4.867927e-03 4.934137e-03 4.358755e-03 3.189530e-03 0.008913 9.533151e-04 1.772871e-03 2.801575e-03 4.640435e-03 4.683883e-03 4.081979e-03 2.890920e-03 0.010000 8.255689e-04 1.599484e-03 2.526937e-03 4.397856e-03 4.416272e-03 3.797163e-03 2.598638e-03 0.011220 7.062716e-04 1.427220e-03 2.254286e-03 4.142128e-03 4.134558e-03 3.508565e-03 2.316836e-03 0.012589 5.962809e-04 1.258516e-03 1.987642e-03 3.875660e-03 3.842623e-03 3.220521e-03 2.049139e-03 0.014125 4.968110e-04 1.095872e-03 1.731292e-03 3.601266e-03 3.544805e-03 2.937090e-03 1.798491e-03 0.015849 4.084180e-04 9.425193e-04 1.489105e-03 3.322102e-03 3.245631e-03 2.661931e-03 1.567057e-03 0.017783 3.308219e-04 8.001721e-04 1.264610e-03 3.041557e-03 2.949582e-03 2.398104e-03 1.356244e-03 0.019953 2.637131e-04 6.704732e-04 1.060321e-03 2.763144e-03 2.660851e-03 2.148081e-03 1.166786e-03 0.022387 2.069182e-04 5.541222e-04 8.779428e-04 2.490356e-03 2.383176e-03 1.913650e-03 9.985218e-04 0.025119 1.599527e-04 4.518091e-04 7.182417e-04 2.226519e-03 2.119665e-03 1.695903e-03 8.496296e-04 0.028184 1.217317e-04 3.633643e-04 5.813573e-04 1.974652e-03 1.872711e-03 1.494955e-03 7.168426e-04 0.031623 9.124870e-05 2.882818e-04 4.664032e-04 1.737340e-03 1.643967e-03 1.309506e-03 5.987592e-04 0.035481 6.735312e-05 2.255027e-04 3.712877e-04 1.516631e-03 1.434360e-03 1.137086e-03 4.965736e-04 0.039811 4.903113e-05 1.739536e-04 2.935491e-04 1.313964e-03 1.244110e-03 9.779615e-04 4.105649e-04 0.044668 3.518388e-05 1.322860e-04 2.307434e-04 1.130134e-03 1.072771e-03 8.355120e-04 3.391524e-04 0.050119 2.491177e-05 9.923609e-05 1.805367e-04 9.653125e-04 9.193863e-04 7.104547e-04 2.801889e-04 0.056234 1.739776e-05 7.345591e-05 1.407387e-04 8.191030e-04 7.828915e-04 6.015805e-04 2.316276e-04 0.063096 1.201140e-05 5.369999e-05 1.094143e-04 6.906228e-04 6.625964e-04 5.074075e-04 1.916654e-04 0.070795 8.195975e-06 3.878495e-05 8.490752e-05 5.786004e-04 5.579095e-04 4.264495e-04 1.587597e-04 0.079433 5.544868e-06 2.771404e-05 6.583692e-05 4.815459e-04 4.677448e-04 3.572506e-04 1.316211e-04 0.089125 3.722086e-06 1.962607e-05 5.105434e-05 3.980057e-04 3.906562e-04 2.984180e-04 1.091907e-04 0.100000 2.488654e-06 1.380285e-05 3.963268e-05 3.267302e-04 3.251528e-04 2.486450e-04 9.060767e-05 0.112202 1.662210e-06 9.661991e-06 3.083110e-05 2.665966e-04 2.698131e-04 2.067250e-04 7.512982e-05 0.125893 1.115629e-06 6.748211e-06 2.405395e-05 2.164338e-04 2.233084e-04 1.715587e-04 6.150380e-05 0.141254 7.532625e-07 4.715069e-06 1.882938e-05 1.749846e-04 1.844159e-04 1.421574e-04 4.923966e-05 0.158489 5.143483e-07 3.304089e-06 1.479308e-05 1.409943e-04 1.520260e-04 1.176392e-04 3.920037e-05

0.177828 3.564407e-07 2.329082e-06 1.166736e-05 1.132953e-04 1.251467e-04 9.720942e-05 3.113048e-05 0.199526 2.511356e-07 1.655790e-06 9.236582e-06 9.083937e-05 1.029003e-04 8.015091e-05 2.463066e-05 0.223872 1.801290e-07 1.189396e-06 7.335094e-06 7.270313e-05 8.451350e-05 6.588668e-05 1.932988e-05 0.251189 1.314071e-07 8.640819e-07 5.838286e-06 5.808895e-05 6.930593e-05 5.399437e-05 1.501812e-05 0.281838 9.742570e-08 6.353169e-07 4.655023e-06 4.632584e-05 5.670059e-05 4.412298e-05 1.157715e-05 0.316228 7.309548e-08 4.727067e-07 3.717178e-06 3.686539e-05 4.625063e-05 3.594370e-05 8.871452e-06 0.354813 5.541119e-08 3.556638e-07 2.971680e-06 2.926710e-05 3.762292e-05 2.915222e-05 6.751877e-06 0.398107 4.230310e-08 2.705463e-07 2.377311e-06 2.317604e-05 3.053374e-05 2.351604e-05 5.073186e-06 0.446684 3.239789e-08 2.082307e-07 1.901975e-06 1.830249e-05 2.471224e-05 1.887344e-05 3.754268e-06 0.501187 2.483493e-08 1.618968e-07 1.520643e-06 1.440934e-05 1.991857e-05 1.507344e-05 2.750464e-06 0.562341 1.903997e-08 1.268977e-07 1.213918e-06 1.130426e-05 1.597257e-05 1.196883e-05 1.982331e-06 0.630957 1.458944e-08 1.002480e-07 9.664418e-07 8.832401e-06 1.274284e-05 9.436829e-06 1.404819e-06 0.707946 1.116217e-08 7.981799e-08 7.662482e-07 6.868878e-06 1.011190e-05 7.380407e-06 9.818469e-07 0.794328 8.515845e-09 6.393244e-08 6.039966e-07 5.312555e-06 7.967362e-06 5.720732e-06 6.731023e-07 0.891251 6.460342e-09 5.140557e-08 4.727213e-07 4.081829e-06 6.217647e-06 4.390808e-06 4.510303e-07 1.000000 4.854198e-09 4.140182e-08 3.671732e-07 3.111515e-06 4.797631e-06 3.334021e-06 2.956251e-07 1.122019 3.610376e-09 3.332739e-08 2.830020e-07 2.349984e-06 3.656989e-06 2.501198e-06 1.891733e-07 1.258925 2.657993e-09 2.675833e-08 2.164802e-07 1.756355e-06 2.750711e-06 1.849068e-06 1.179944e-07 1.412538 1.935821e-09 2.138564e-08 1.644116e-07 1.297897e-06 2.038617e-06 1.342589e-06 7.126396e-08 1.584893 1.395385e-09 1.698288e-08 1.240278e-07 9.478614e-07 1.486318e-06 9.542652e-07 4.116235e-08 1.778279 9.952646e-10 1.338316e-08 9.295954e-08 6.839558e-07 1.064685e-06 6.614087e-07 2.239401e-08 1.995262 7.017061e-10 1.045505e-08 6.922579e-08 4.874836e-07 7.485408e-07 4.452795e-07 1.135408e-08 2.238721 4.881570e-10 8.088420e-09 5.121050e-08 3.429711e-07 5.156997e-07 2.901743e-07 5.297870e-09 2.511886 3.342954e-10 6.190217e-09 3.761692e-08 2.379291e-07 3.475174e-07 1.822590e-07 2.222601e-09 2.818383 2.244690e-10 4.684100e-09 2.741906e-08 1.625222e-07 2.281104e-07 1.096182e-07 8.052952e-10 3.162278 1.585571e-10 3.637085e-09 2.080619e-08 1.171991e-07 1.578637e-07 7.162819e-08 4.299880e-10 3.548134 9.264529e-11 2.590071e-09 1.419332e-08 7.187597e-08 8.761689e-08 3.363821e-08 5.468083e-11 Point Beach (44.28° N, 87.54° E), Response Spectra Frequency (Hz)

UHRS 1E-4 (g)

GMRS (g)

UHRS 1E-5 (g) 0.500000 0.030487 0.034210 0.066677 0.561009 0.032489 0.036506 0.071175 0.629463 0.034873 0.039215 0.076472 0.706269 0.037760 0.042559 0.083041 0.792447 0.041256 0.046656 0.091112 0.889140 0.045399 0.051509 0.100670 0.997631 0.049868 0.056649 0.110750 1.000000 0.049965 0.056758 0.110963 1.122019 0.052915 0.061329 0.120502 1.258925 0.055112 0.065196 0.128758 1.412538 0.056289 0.068150 0.135376 1.584893 0.056976 0.070808 0.141577 1.778279 0.057489 0.073565 0.148167 1.995262 0.058463 0.077163 0.156622 2.238721 0.061007 0.083317 0.170561 2.500000 0.065726 0.092919 0.191869 2.805046 0.075340 0.112529 0.235579

3.147313 0.091507 0.141049 0.297618 3.531344 0.115601 0.176539 0.371640 3.962233 0.141864 0.211744 0.443207 4.445698 0.165513 0.248030 0.519676 4.988156 0.189781 0.284233 0.595445 5.000000 0.190281 0.284999 0.597059 5.610092 0.201785 0.305699 0.642254 6.294627 0.208622 0.321678 0.678809 7.062688 0.208843 0.327926 0.695147 7.924466 0.205458 0.326186 0.693364 8.891397 0.201527 0.326447 0.697418 9.976312 0.202806 0.332075 0.711355 10.000000 0.202891 0.332255 0.711761 11.220185 0.197142 0.323655 0.693775 12.589254 0.197354 0.326294 0.700664 14.125375 0.194070 0.319617 0.685659 15.848932 0.188651 0.312078 0.670231 17.782794 0.183321 0.305648 0.657711 19.952623 0.181190 0.298359 0.640031 22.387211 0.174816 0.286360 0.613488 25.000000 0.173711 0.279549 0.596247 28.050461 0.170106 0.268634 0.570272 31.473135 0.167534 0.262862 0.557116 35.313439 0.163492 0.255260 0.540337 39.622330 0.156566 0.239527 0.504462 44.456985 0.151064 0.225851 0.472931 49.881558 0.146031 0.215026 0.448552 55.968028 0.140508 0.203902 0.423800 62.797161 0.134110 0.192375 0.398687 70.459573 0.127289 0.182101 0.377141 79.056942 0.119505 0.171990 0.356734 88.703347 0.111085 0.162429 0.338240 99.526793 0.102770 0.153754 0.322016 100.000000 0.094095 0.142847 0.300267