Fermi (41.96° N, 83.26° E), Control Point Hazard SA (g)

AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.752074e-03 7.824070e-03 1.142228e-02 1.205579e-02 1.216396e-02 1.201809e-02 1.128545e-02 0.001122 4.502037e-03 7.504474e-03 1.141801e-02 1.205579e-02 1.213958e-02 1.201151e-02 1.128545e-02 0.001259 4.258756e-03 7.120303e-03 1.135449e-02 1.205572e-02 1.206340e-02 1.192864e-02 1.127638e-02 0.001413 4.027696e-03 6.742130e-03 1.122577e-02 1.205435e-02 1.196419e-02 1.180967e-02 1.115079e-02 0.001585 3.808169e-03 6.369117e-03 1.103836e-02 1.204337e-02 1.184353e-02 1.166632e-02 1.089725e-02 0.001778 3.598071e-03 6.004357e-03 1.080568e-02 1.200326e-02 1.169852e-02 1.149810e-02 1.060651e-02 0.001995 3.397109e-03 5.649067e-03 1.053005e-02 1.191236e-02 1.152563e-02 1.130038e-02 1.028360e-02 0.002239 3.202329e-03 5.304810e-03 1.021999e-02 1.177843e-02 1.132319e-02 1.107267e-02 9.925287e-03 0.002512 3.013525e-03 4.971651e-03 9.881950e-03 1.162175e-02 1.108806e-02 1.081222e-02 9.533069e-03 0.002818 2.827398e-03 4.649453e-03 9.518324e-03 1.143780e-02 1.081830e-02 1.051804e-02 9.109386e-03 0.003162 2.644417e-03 4.338330e-03 9.130745e-03 1.122380e-02 1.051202e-02 1.018861e-02 8.656105e-03 0.003548 2.461586e-03 4.036711e-03 8.721449e-03 1.097807e-02 1.016952e-02 9.825371e-03 8.176452e-03 0.003981 2.279800e-03 3.744457e-03 8.292851e-03 1.069905e-02 9.790827e-03 9.429635e-03 7.675164e-03 0.004467 2.097254e-03 3.459232e-03 7.847594e-03 1.038512e-02 9.377870e-03 9.004150e-03 7.158392e-03 0.005012 1.915217e-03 3.181057e-03 7.388256e-03 1.003559e-02 8.933023e-03 8.552928e-03 6.632199e-03 0.005623 1.733768e-03 2.908037e-03 6.917620e-03 9.650674e-03 8.460215e-03 8.080101e-03 6.103569e-03 0.006310 1.554484e-03 2.640801e-03 6.438455e-03 9.231460e-03 7.964419e-03 7.592016e-03 5.579204e-03 0.007079 1.379250e-03 2.378989e-03 5.953821e-03 8.779632e-03 7.451338e-03 7.093778e-03 5.065942e-03 0.007943 1.209373e-03 2.123721e-03 5.467081e-03 8.298093e-03 6.927612e-03 6.592633e-03 4.569963e-03 0.008913 1.048024e-03 1.876786e-03 4.981825e-03 7.790697e-03 6.399525e-03 6.093368e-03 4.096651e-03 0.010000 8.960092e-04 1.639814e-03 4.502415e-03 7.262704e-03 5.874403e-03 5.602747e-03 3.650314e-03 0.011220 7.564957e-04 1.415996e-03 4.033244e-03 6.720282e-03 5.358195e-03 5.124746e-03 3.234087e-03 0.012589 6.292805e-04 1.206549e-03 3.579537e-03 6.170551e-03 4.857277e-03 4.664520e-03 2.850177e-03 0.014125 5.169280e-04 1.015592e-03 3.145841e-03 5.621038e-03 4.376198e-03 4.224533e-03 2.495250e-03 0.015849 4.180218e-04 8.442937e-04 2.737305e-03 5.079550e-03 3.919718e-03 3.807883e-03 2.159370e-03 0.017783 3.337698e-04 6.928926e-04 2.357537e-03 4.553641e-03 3.490205e-03 3.398114e-03 1.850343e-03 0.019953 2.624368e-04 5.607254e-04 2.010067e-03 4.049996e-03 3.090478e-03 2.992866e-03 1.578761e-03 0.022387 2.039509e-04 4.483098e-04 1.696734e-03 3.574387e-03 2.720995e-03 2.614956e-03 1.342269e-03 0.025119 1.560845e-04 3.535967e-04 1.419056e-03 3.131120e-03 2.377032e-03 2.271818e-03 1.137718e-03 0.028184 1.181193e-04 2.756934e-04 1.176761e-03 2.723256e-03 2.061195e-03 1.963010e-03 9.619017e-04 0.031623 8.811615e-05 2.123721e-04 9.683348e-04 2.352278e-03 1.776807e-03 1.687328e-03 8.115267e-04 0.035481 6.511160e-05 1.619553e-04 7.911166e-04 2.018737e-03 1.523666e-03 1.443078e-03 6.835089e-04 0.039811 4.750427e-05 1.220820e-04 6.422811e-04 1.721661e-03 1.300295e-03 1.228178e-03 5.748632e-04 0.044668 3.439902e-05 9.132284e-05 5.185189e-04 1.459534e-03 1.104557e-03 1.040526e-03 4.828774e-04 0.050119 2.465175e-05 6.783917e-05 4.166094e-04 1.230284e-03 9.342748e-04 8.777649e-04 4.050927e-04 0.056234 1.758360e-05 5.016212e-05 3.333870e-04 1.031934e-03 7.870927e-04 7.376027e-04 3.393818e-04 0.063096 1.246159e-05 3.696241e-05 2.659676e-04 8.616301e-04 6.606981e-04 6.176390e-04 2.838710e-04 0.070795 8.821894e-06 2.720741e-05 2.116898e-04 7.164887e-04 5.527829e-04 5.155861e-04 2.360850e-04 0.079433 6.237522e-06 2.004405e-05 1.682131e-04 5.935781e-04 4.611415e-04 4.292752e-04 1.948254e-04 0.089125 4.424125e-06 1.480271e-05 1.335211e-04 4.901482e-04 3.836935e-04 3.568824e-04 1.603195e-04 0.100000 3.152515e-06 1.097988e-05 1.059358e-04 4.035708e-04 3.185362e-04 2.968756e-04 1.315939e-04 0.112202 2.261777e-06 8.185952e-06 8.405059e-05 3.314697e-04 2.640392e-04 2.474474e-04 1.077166e-04 0.125893 1.638089e-06 6.139878e-06 6.670815e-05 2.716599e-04 2.187088e-04 2.063615e-04 8.787308e-05 0.141254 1.197157e-06 4.632026e-06 5.297129e-05 2.222077e-04 1.809924e-04 1.718661e-04 7.133142e-05 0.158489 8.851490e-07 3.515094e-06 4.208761e-05 1.813887e-04 1.495537e-04 1.428672e-04 5.765987e-05

0.177828 6.604232e-07 2.681450e-06 3.346201e-05 1.477285e-04 1.233739e-04 1.185275e-04 4.644470e-05 0.199526 4.978136e-07 2.054288e-06 2.661611e-05 1.200429e-04 1.016064e-04 9.813346e-05 3.725776e-05 0.223872 3.776500e-07 1.579520e-06 2.117377e-05 9.738987e-05 8.351400e-05 8.105621e-05 2.974546e-05 0.251189 2.885172e-07 1.217069e-06 1.684289e-05 7.887961e-05 6.846507e-05 6.675736e-05 2.359048e-05 0.281838 2.213166e-07 9.386864e-07 1.339209e-05 6.374927e-05 5.597863e-05 5.480638e-05 1.856313e-05 0.316228 1.701230e-07 7.241412e-07 1.063996e-05 5.138421e-05 4.564983e-05 4.484146e-05 1.451333e-05 0.354813 1.317469e-07 5.584740e-07 8.443316e-06 4.131825e-05 3.711667e-05 3.654049e-05 1.126994e-05 0.398107 1.025395e-07 4.299392e-07 6.688094e-06 3.315016e-05 3.006101e-05 2.962884e-05 8.677101e-06 0.446684 7.996345e-08 3.303793e-07 5.285962e-06 2.652141e-05 2.423410e-05 2.388842e-05 6.621253e-06 0.501187 6.206508e-08 2.531411e-07 4.166841e-06 2.113735e-05 1.944591e-05 1.914100e-05 5.007490e-06 0.562341 4.781909e-08 1.934784e-07 3.275420e-06 1.676022e-05 1.552018e-05 1.522879e-05 3.751107e-06 0.630957 3.675639e-08 1.476200e-07 2.566740e-06 1.321615e-05 1.230175e-05 1.201566e-05 2.785632e-06 0.707946 2.820961e-08 1.125154e-07 2.004110e-06 1.036490e-05 9.675944e-06 9.390274e-06 2.052600e-06 0.794328 2.153793e-08 8.609653e-08 1.558158e-06 8.077863e-06 7.542944e-06 7.260813e-06 1.499640e-06 0.891251 1.630144e-08 6.614214e-08 1.205138e-06 6.249432e-06 5.816913e-06 5.549807e-06 1.085821e-06 1.000000 1.219598e-08 5.071482e-08 9.263105e-07 4.795366e-06 4.435132e-06 4.190735e-06 7.791132e-07 1.122019 9.033515e-09 3.854181e-08 7.070264e-07 3.646693e-06 3.341133e-06 3.124074e-06 5.539355e-07 1.258925 6.597816e-09 2.920489e-08 5.345856e-07 2.746560e-06 2.479515e-06 2.296924e-06 3.904431e-07 1.412538 4.750004e-09 2.204395e-08 3.990447e-07 2.050253e-06 1.808554e-06 1.664028e-06 2.728812e-07 1.584893 3.370177e-09 1.655307e-08 2.922517e-07 1.513682e-06 1.292976e-06 1.186659e-06 1.891004e-07 1.778279 2.359698e-09 1.236357e-08 2.103252e-07 1.102198e-06 9.040380e-07 8.319792e-07 1.296877e-07 1.995262 1.626813e-09 9.174331e-09 1.489563e-07 7.924747e-07 6.172792e-07 5.726539e-07 8.743241e-08 2.238721 1.102213e-09 6.746329e-09 1.035793e-07 5.627021e-07 4.107883e-07 3.850917e-07 5.720872e-08 2.511886 7.292165e-10 4.896333e-09 6.981121e-08 3.945860e-07 2.648437e-07 2.489279e-07 3.566382e-08 2.818383 4.675320e-10 3.487395e-09 4.439112e-08 2.727687e-07 1.642603e-07 1.492935e-07 2.043524e-08 3.162278 3.139656e-10 2.543497e-09 3.025861e-08 1.984680e-07 1.073671e-07 9.193142e-08 1.176294e-08 3.548134 1.603992e-10 1.599599e-09 1.612611e-08 1.241673e-07 5.047395e-08 3.456937e-08 3.090636e-09 Fermi (41.96° N, 83.26° E), Response Spectra Frequency (Hz)

UHRS 1E-4 (g)

GMRS (g)

UHRS 1E-5 (g) 0.500000 0.030089 0.034619 0.067898 0.561009 0.031817 0.036987 0.072729 0.629463 0.033671 0.039538 0.077940 0.706269 0.035740 0.042329 0.083623 0.792447 0.037967 0.045322 0.089710 0.889140 0.040405 0.048581 0.096336 0.997631 0.043032 0.052134 0.103577 1.000000 0.043089 0.052211 0.103733 1.122019 0.046580 0.059313 0.119316 1.258925 0.050703 0.067424 0.137110 1.412538 0.055641 0.076667 0.157297 1.584893 0.061427 0.087216 0.180289 1.778279 0.068748 0.099871 0.207632 1.995262 0.077612 0.114661 0.239387 2.238721 0.088898 0.133135 0.278902 2.500000 0.102910 0.155372 0.326147 2.805046 0.124155 0.193016 0.408142

3.147313 0.149497 0.235661 0.500047 3.531344 0.175134 0.276295 0.586387 3.962233 0.197793 0.310101 0.657110 4.445698 0.212680 0.331024 0.700169 4.988156 0.220636 0.340908 0.719761 5.000000 0.220770 0.341062 0.720059 5.610092 0.216436 0.338429 0.716660 6.294627 0.209013 0.330564 0.702000 7.062688 0.200901 0.320859 0.683059 7.924466 0.195291 0.314487 0.670878 8.891397 0.195409 0.316237 0.675445 9.976312 0.201245 0.325944 0.696320 10.000000 0.201402 0.326194 0.696851 11.220185 0.200595 0.326010 0.697061 12.589254 0.202493 0.329372 0.704396 14.125375 0.204392 0.332484 0.711065 15.848932 0.204012 0.331976 0.710036 17.782794 0.200694 0.327150 0.700022 19.952623 0.197883 0.322875 0.691037 22.387211 0.197247 0.321326 0.687450 25.000000 0.196020 0.317732 0.678909 28.050461 0.198888 0.321096 0.685414 31.473135 0.203237 0.326712 0.696654 35.313439 0.206708 0.330587 0.704010 39.622330 0.206778 0.329176 0.700197 44.456985 0.205944 0.325696 0.691654 49.881558 0.201892 0.317854 0.674243 55.968028 0.192155 0.300903 0.637428 62.797161 0.179673 0.279835 0.591995 70.459573 0.165066 0.255277 0.539090 79.056942 0.150460 0.230400 0.485355 88.703347 0.137458 0.209022 0.439549 99.526793 0.127119 0.192913 0.405473 100.000000 0.117018 0.177866 0.373993