Pilgrim (41.94° N, 70.58° E), Control Point Hazard SA (g)
AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.072555e-03 7.297521e-03 1.076847e-02 1.136969e-02 0.011477 0.011329 1.062622e-02 0.001122 3.777750e-03 6.895323e-03 1.057175e-02 1.134396e-02 0.011475 0.011329 1.062527e-02 0.001259 3.494014e-03 6.504261e-03 1.034098e-02 1.127759e-02 0.011471 0.011328 1.061512e-02 0.001413 3.221247e-03 6.112949e-03 1.008556e-02 1.118195e-02 0.011462 0.011324 1.057045e-02 0.001585 2.959109e-03 5.722138e-03 9.801509e-03 1.105927e-02 0.011447 0.011300 1.046637e-02 0.001778 2.707870e-03 5.335354e-03 9.488193e-03 1.090905e-02 0.011424 0.011226 1.029483e-02 0.001995 2.467934e-03 4.954602e-03 9.148402e-03 1.072968e-02 0.011389 0.011118 1.005912e-02 0.002239 2.239459e-03 4.582376e-03 8.782821e-03 1.052073e-02 0.011341 0.010985 9.773367e-03 0.002512 2.022153e-03 4.219102e-03 8.392863e-03 1.028148e-02 0.011276 0.010826 9.452497e-03 0.002818 1.816554e-03 3.867029e-03 7.980595e-03 1.001132e-02 0.011190 0.010639 9.103391e-03 0.003162 1.622741e-03 3.527206e-03 7.549667e-03 9.710071e-03 0.011080 0.010425 8.728911e-03 0.003548 1.441384e-03 3.201412e-03 7.103630e-03 9.378492e-03 0.010944 0.010184 8.332126e-03 0.003981 1.272195e-03 2.890059e-03 6.645972e-03 9.017844e-03 0.010782 0.009914 7.916796e-03 0.004467 1.115959e-03 2.594848e-03 6.181502e-03 8.630268e-03 0.010593 0.009617 7.487214e-03 0.005012 9.720872e-04 2.315763e-03 5.713690e-03 8.218508e-03 0.010376 0.009293 7.048060e-03 0.005623 8.412941e-04 2.054495e-03 5.248345e-03 7.786091e-03 0.010133 0.008946 6.604189e-03 0.006310 7.227279e-04 1.810664e-03 4.788799e-03 7.337150e-03 0.009862 0.008578 6.160366e-03 0.007079 6.172461e-04 1.585758e-03 4.341106e-03 6.876289e-03 0.009564 0.008193 5.721059e-03 0.007943 5.238570e-04 1.378849e-03 3.907682e-03 6.408423e-03 0.009241 0.007793 5.290336e-03 0.008913 4.413117e-04 1.191162e-03 3.494292e-03 5.938541e-03 0.008894 0.007384 4.871745e-03 0.010000 3.688207e-04 1.021378e-03 3.102460e-03 5.471777e-03 0.008526 0.006969 4.468269e-03 0.011220 3.063430e-04 8.701449e-04 2.736697e-03 5.012911e-03 0.008138 0.006552 4.082300e-03 0.012589 2.526053e-04 7.359247e-04 2.397120e-03 4.566494e-03 0.007736 0.006137 3.715992e-03 0.014125 2.072051e-04 6.191720e-04 2.086939e-03 4.136457e-03 0.007322 0.005728 3.372774e-03 0.015849 1.689011e-04 5.169363e-04 1.804751e-03 3.726290e-03 0.006900 0.005327 3.056922e-03 0.017783 1.371191e-04 4.290701e-04 1.551869e-03 3.338536e-03 0.006474 0.004936 2.768958e-03 0.019953 1.107494e-04 3.537957e-04 1.326590e-03 2.975393e-03 0.006048 0.004558 2.506051e-03 0.022387 8.917490e-05 2.903637e-04 1.129294e-03 2.638257e-03 0.005626 0.004193 2.264097e-03 0.025119 7.152612e-05 2.369371e-04 9.580440e-04 2.328124e-03 0.005211 0.003842 2.040144e-03 0.028184 5.725337e-05 1.926092e-04 8.095694e-04 2.046329e-03 0.004806 0.003509 1.833265e-03 0.031623 4.571706e-05 1.558884e-04 6.812232e-04 1.792275e-03 0.004415 0.003194 1.643067e-03 0.035481 3.647053e-05 1.258605e-04 5.713053e-04 1.564335e-03 0.004039 0.002897 1.468934e-03 0.039811 2.906007e-05 1.012700e-04 4.774311e-04 1.360675e-03 0.003680 0.002618 1.310092e-03 0.044668 2.315084e-05 8.133758e-05 3.978331e-04 1.179554e-03 0.003341 0.002358 1.165691e-03 0.050119 1.843797e-05 6.518374e-05 3.305021e-04 1.019241e-03 0.003021 0.002115 1.034841e-03 0.056234 1.468757e-05 5.217867e-05 2.738618e-04 8.778506e-04 0.002721 0.001890 9.166557e-04 0.063096 1.170284e-05 4.169984e-05 2.263194e-04 7.536451e-04 0.002441 0.001683 8.102209e-04 0.070795 9.326900e-06 3.329829e-05 1.865125e-04 6.449342e-04 0.002181 0.001494 7.146385e-04 0.079433 7.435674e-06 2.656244e-05 1.531959e-04 5.501893e-04 0.001941 0.001320 6.290079e-04 0.089125 5.928130e-06 2.117449e-05 1.255168e-04 4.679235e-04 0.001719 0.001163 5.524557e-04 0.100000 4.726378e-06 1.686368e-05 1.025825e-04 3.967668e-04 0.001517 0.001021 4.838576e-04 0.112202 3.766936e-06 1.341884e-05 8.364065e-05 3.354021e-04 0.001334 0.000894 4.213654e-04 0.125893 3.000979e-06 1.066697e-05 6.800585e-05 2.826859e-04 0.001168 0.000779 3.630005e-04 0.141254 2.388753e-06 8.470462e-06 5.516208e-05 2.375750e-04 0.001018 0.000678 3.092286e-04 0.158489 1.899358e-06 6.717125e-06 4.462980e-05 1.991028e-04 0.000885 0.000588 2.623733e-04
0.177828 1.508053e-06 5.319083e-06 3.601642e-05 1.663725e-04 0.000766 0.000508 2.219287e-04 0.199526 1.195274e-06 4.204709e-06 2.898693e-05 1.386146e-04 0.000660 0.000438 1.870914e-04 0.223872 9.454821e-07 3.317832e-06 2.326992e-05 1.151608e-04 0.000568 0.000376 1.570824e-04 0.251189 7.459872e-07 2.611821e-06 1.863212e-05 9.541949e-05 0.000486 0.000321 1.309967e-04 0.281838 5.870602e-07 2.050913e-06 1.487467e-05 7.885488e-05 0.000414 0.000273 1.081437e-04 0.316228 4.604194e-07 1.605807e-06 1.183889e-05 6.499976e-05 0.000352 0.000232 8.893822e-05 0.354813 3.600719e-07 1.253382e-06 9.394559e-06 5.344793e-05 0.000298 0.000196 7.289359e-05 0.398107 2.806865e-07 9.745912e-07 7.429903e-06 4.384948e-05 0.000251 0.000165 5.946684e-05 0.446684 2.180629e-07 7.549347e-07 5.856027e-06 3.589177e-05 0.000211 0.000139 4.818822e-05 0.501187 1.686077e-07 5.821478e-07 4.599281e-06 2.930677e-05 0.000176 0.000116 3.861021e-05 0.562341 1.297672e-07 4.470089e-07 3.598814e-06 2.386690e-05 0.000147 0.000096 3.056414e-05 0.630957 9.924706e-08 3.415643e-07 2.803171e-06 1.938080e-05 0.000122 0.000080 2.402326e-05 0.707946 7.545363e-08 2.593473e-07 2.173828e-06 1.568946e-05 0.000101 0.000066 1.871352e-05 0.794328 5.681433e-08 1.962709e-07 1.677896e-06 1.265783e-05 0.000083 0.000054 1.440861e-05 0.891251 4.227723e-08 1.482577e-07 1.288979e-06 1.017442e-05 0.000068 0.000044 1.097298e-05 1.000000 3.115883e-08 1.111034e-07 9.848836e-07 8.145610e-06 0.000055 0.000036 8.221539e-06 1.122019 2.276105e-08 8.262301e-08 7.484559e-07 6.494316e-06 0.000044 0.000029 6.054152e-06 1.258925 1.643609e-08 6.084774e-08 5.656004e-07 5.156067e-06 0.000036 0.000023 4.366760e-06 1.412538 1.174224e-08 4.437286e-08 4.251725e-07 4.074091e-06 0.000028 0.000018 3.087473e-06 1.584893 8.268212e-09 3.197697e-08 3.177092e-07 3.200720e-06 0.000023 0.000014 2.142858e-06 1.778279 5.737859e-09 2.275314e-08 2.363887e-07 2.497206e-06 0.000018 0.000011 1.450453e-06 1.995262 3.903728e-09 1.583071e-08 1.753756e-07 1.932485e-06 0.000014 0.000008 9.517659e-07 2.238721 2.597113e-09 1.071977e-08 1.292872e-07 1.481496e-06 0.000011 0.000006 6.045974e-07 2.511886 1.669463e-09 7.025553e-09 9.423328e-08 1.123309e-06 0.000008 0.000004 3.676526e-07 2.818383 1.023045e-09 4.418187e-09 6.759063e-08 8.402627e-07 0.000006 0.000003 2.120258e-07 3.162278 6.466823e-10 2.881295e-09 4.993268e-08 6.420875e-07 0.000005 0.000002 1.332238e-07 3.548134 2.703194e-10 1.344402e-09 3.227474e-08 4.439123e-07 0.000003 0.000001 5.442171e-08 Pilgrim (41.94° N, 70.58° E), Response Spectra Frequency (Hz)
UHRS 1E-4 (g)
GMRS (g)
UHRS 1E-5 (g) 0.068336 0.009471 0.015750 0.032403 0.078468 0.010778 0.017980 0.037143 0.088498 0.012152 0.020267 0.041876 0.098548 0.013591 0.022612 0.046642 0.108716 0.015090 0.025024 0.051482 0.119099 0.016652 0.027512 0.056436 0.129794 0.018279 0.030089 0.061543 0.130017 0.018313 0.030143 0.061649 0.154435 0.020900 0.034910 0.072729 0.178931 0.023680 0.039940 0.083968 0.203749 0.026655 0.045242 0.095473 0.229144 0.029850 0.050846 0.107346 0.255468 0.033299 0.056800 0.119738 0.283135 0.037037 0.063157 0.132815 0.312970 0.041122 0.070059 0.146942 0.343951 0.045444 0.077319 0.161658 0.402660 0.051328 0.088575 0.188233
0.468175 0.058219 0.101514 0.218069 0.544307 0.066497 0.116841 0.252912 0.635427 0.076577 0.135239 0.294666 0.750003 0.089400 0.158577 0.347194 0.899265 0.106133 0.188805 0.415688 0.902718 0.106524 0.189504 0.417276 1.102107 0.126471 0.227973 0.507365 1.353337 0.153426 0.278627 0.622320 1.633977 0.188841 0.343517 0.754957 1.903858 0.230575 0.415850 0.887729 2.116992 0.270016 0.480818 0.997093 2.295594 0.304217 0.535191 1.088802 2.299300 0.304931 0.536312 1.090708 2.312577 0.308876 0.542417 1.098091 2.277058 0.304861 0.535788 1.082264 2.192889 0.290860 0.513719 1.041447 2.074124 0.270577 0.482282 0.982665 1.922706 0.247929 0.443121 0.909101 1.838682 0.232612 0.418018 0.866325 1.834313 0.231657 0.418866 0.864828 1.836915 0.236824 0.427465 0.869909 1.844532 0.241750 0.433247 0.876179 1.905726 0.246980 0.442530 0.902479 1.885933 0.251236 0.448692 0.897941 1.824714 0.245869 0.435771 0.870262 1.777036 0.240479 0.425295 0.847844 1.656454 0.226502 0.399212 0.791714 1.546976 0.213061 0.375240 0.740421 1.413320 0.196190 0.344176 0.677353 1.317470 0.181090 0.318856 0.630301 1.199078 0.165922 0.292054 0.574674 1.082695 0.149300 0.262802 0.518658 1.000981 0.136354 0.241142 0.478678 0.924873 0.124575 0.221441 0.441592