Waterford (30.00° N, 90.47° E), Control Point Hazard SA (g)
AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.805529e-03 7.196517e-03 1.024542e-02 1.087368e-02 1.095444e-02 1.072490e-02 9.733173e-03 0.001122 4.805529e-03 7.196517e-03 1.024542e-02 1.087150e-02 1.091798e-02 1.072477e-02 9.733173e-03 0.001259 4.805528e-03 7.196517e-03 1.024541e-02 1.085964e-02 1.085310e-02 1.071885e-02 9.733173e-03 0.001413 4.805510e-03 7.196517e-03 1.024528e-02 1.082730e-02 1.075426e-02 1.067733e-02 9.733172e-03 0.001585 4.805336e-03 7.196513e-03 1.024411e-02 1.076956e-02 1.063456e-02 1.058036e-02 9.732691e-03 0.001778 4.804167e-03 7.196460e-03 1.023739e-02 1.068247e-02 1.049583e-02 1.045117e-02 9.716600e-03 0.001995 4.798872e-03 7.195913e-03 1.021236e-02 1.056184e-02 1.032980e-02 1.029244e-02 9.621911e-03 0.002239 4.781952e-03 7.192162e-03 1.014718e-02 1.040746e-02 1.012890e-02 1.008784e-02 9.430113e-03 0.002512 4.741743e-03 7.174213e-03 1.001995e-02 1.021967e-02 9.896125e-03 9.853699e-03 9.174781e-03 0.002818 4.666686e-03 7.112991e-03 9.823871e-03 9.999061e-03 9.636774e-03 9.595845e-03 8.853947e-03 0.003162 4.551354e-03 6.968131e-03 9.572639e-03 9.748094e-03 9.352432e-03 9.313669e-03 8.504162e-03 0.003548 4.399382e-03 6.730969e-03 9.285711e-03 9.469619e-03 9.043675e-03 9.007533e-03 8.135222e-03 0.003981 4.221386e-03 6.438770e-03 8.974230e-03 9.165565e-03 8.711729e-03 8.678738e-03 7.749016e-03 0.004467 4.030352e-03 6.129874e-03 8.642526e-03 8.837348e-03 8.357991e-03 8.328827e-03 7.348109e-03 0.005012 3.836646e-03 5.821482e-03 8.293230e-03 8.486528e-03 7.984178e-03 7.959537e-03 6.935088e-03 0.005623 3.645436e-03 5.518956e-03 7.928961e-03 8.114982e-03 7.592361e-03 7.572967e-03 6.512656e-03 0.006310 3.457920e-03 5.223949e-03 7.552497e-03 7.724865e-03 7.185067e-03 7.171620e-03 6.083470e-03 0.007079 3.273629e-03 4.937006e-03 7.166752e-03 7.318563e-03 6.765131e-03 6.758209e-03 5.650283e-03 0.007943 3.091686e-03 4.658203e-03 6.774648e-03 6.898671e-03 6.335662e-03 6.335783e-03 5.216055e-03 0.008913 2.911199e-03 4.387314e-03 6.378901e-03 6.467938e-03 5.900100e-03 5.907654e-03 4.783785e-03 0.010000 2.731382e-03 4.123839e-03 5.981872e-03 6.029289e-03 5.462068e-03 5.477351e-03 4.356895e-03 0.011220 2.551632e-03 3.867021e-03 5.585507e-03 5.585871e-03 5.025537e-03 5.048634e-03 3.939010e-03 0.012589 2.371610e-03 3.615912e-03 5.191348e-03 5.141073e-03 4.594422e-03 4.625428e-03 3.534025e-03 0.014125 2.191344e-03 3.369473e-03 4.800592e-03 4.698551e-03 4.172825e-03 4.211631e-03 3.145850e-03 0.015849 2.011295e-03 3.126715e-03 4.414217e-03 4.262206e-03 3.764372e-03 3.810894e-03 2.778113e-03 0.017783 1.832346e-03 2.886832e-03 4.033165e-03 3.836118e-03 3.372781e-03 3.424414e-03 2.432638e-03 0.019953 1.655634e-03 2.649355e-03 3.658575e-03 3.424362e-03 2.998824e-03 3.029271e-03 2.094158e-03 0.022387 1.482383e-03 2.414258e-03 3.291977e-03 3.030916e-03 2.633493e-03 2.592247e-03 1.745770e-03 0.025119 1.313928e-03 2.182090e-03 2.935413e-03 2.659226e-03 2.278367e-03 2.150273e-03 1.416875e-03 0.028184 1.151856e-03 1.953980e-03 2.591437e-03 2.311229e-03 1.942298e-03 1.757749e-03 1.126064e-03 0.031623 9.979650e-04 1.731491e-03 2.262954e-03 1.987329e-03 1.634953e-03 1.413014e-03 8.808558e-04 0.035481 8.540522e-04 1.516259e-03 1.952868e-03 1.689369e-03 1.365533e-03 1.117718e-03 6.840279e-04 0.039811 7.216794e-04 1.309770e-03 1.663671e-03 1.420195e-03 1.133495e-03 8.769739e-04 5.289052e-04 0.044668 6.019613e-04 1.113976e-03 1.397476e-03 1.180900e-03 9.340786e-04 6.841812e-04 4.079951e-04 0.050119 4.954493e-04 9.320028e-04 1.156410e-03 9.718113e-04 7.636483e-04 5.315545e-04 3.144534e-04 0.056234 4.022418e-04 7.671220e-04 9.424900e-04 7.925080e-04 6.203112e-04 4.122075e-04 2.423223e-04 0.063096 3.221339e-04 6.213244e-04 7.569401e-04 6.411942e-04 5.016246e-04 3.198560e-04 1.867454e-04 0.070795 2.545582e-04 4.951955e-04 5.996871e-04 5.152280e-04 4.043536e-04 2.487568e-04 1.438678e-04 0.079433 1.985440e-04 3.882898e-04 4.692772e-04 4.116226e-04 3.250988e-04 1.940191e-04 1.108410e-04 0.089125 1.528650e-04 2.994291e-04 3.632031e-04 3.272447e-04 2.607024e-04 1.514287e-04 8.541780e-05 0.100000 1.162135e-04 2.269942e-04 2.783901e-04 2.590759e-04 2.085566e-04 1.180879e-04 6.554783e-05 0.112202 8.727034e-05 1.692218e-04 2.115915e-04 2.043837e-04 1.665294e-04 9.200587e-05 4.996280e-05 0.125893 6.475257e-05 1.241847e-04 1.596700e-04 1.607145e-04 1.327585e-04 7.162030e-05 3.796931e-05 0.141254 4.747825e-05 8.977223e-05 1.197812e-04 1.259554e-04 1.056521e-04 5.573076e-05 2.878653e-05 0.158489 3.443553e-05 6.394110e-05 8.945008e-05 9.840024e-05 8.388674e-05 4.339043e-05 2.170674e-05
0.177828 2.473502e-05 4.492335e-05 6.659123e-05 7.666904e-05 6.640957e-05 3.376225e-05 1.622525e-05 0.199526 1.760288e-05 3.121419e-05 4.950287e-05 5.959757e-05 5.237499e-05 2.618101e-05 1.201420e-05 0.223872 1.240937e-05 2.151168e-05 3.680940e-05 4.621228e-05 4.112257e-05 2.016203e-05 8.812919e-06 0.251189 8.658905e-06 1.473846e-05 2.740407e-05 3.573939e-05 3.215263e-05 1.537782e-05 6.390150e-06 0.281838 5.988416e-06 1.006085e-05 2.043037e-05 2.757039e-05 2.503158e-05 1.158690e-05 4.566941e-06 0.316228 4.109599e-06 6.861280e-06 1.525224e-05 2.120525e-05 1.936598e-05 8.623924e-06 3.210400e-06 0.354813 2.795590e-06 4.688861e-06 1.139836e-05 1.623159e-05 1.486312e-05 6.336691e-06 2.216344e-06 0.398107 1.887959e-06 3.218469e-06 8.516780e-06 1.233814e-05 1.130903e-05 4.581995e-06 1.498584e-06 0.446684 1.270199e-06 2.222587e-06 6.350376e-06 9.307779e-06 8.522952e-06 3.242921e-06 9.890267e-07 0.501187 8.556426e-07 1.544797e-06 4.716312e-06 6.976693e-06 6.349018e-06 2.236040e-06 6.356215e-07 0.562341 5.813062e-07 1.079089e-06 3.483475e-06 5.200423e-06 4.659320e-06 1.496009e-06 3.972222e-07 0.630957 4.003445e-07 7.566326e-07 2.555189e-06 3.847797e-06 3.354354e-06 9.658386e-07 2.412048e-07 0.707946 2.797482e-07 5.322557e-07 1.858899e-06 2.809516e-06 2.361116e-06 5.988087e-07 1.420954e-07 0.794328 1.983185e-07 3.746909e-07 1.339313e-06 2.008235e-06 1.621381e-06 3.545600e-07 8.078322e-08 0.891251 1.426815e-07 2.632117e-07 9.540029e-07 1.397896e-06 1.082760e-06 1.989644e-07 4.403190e-08 1.000000 1.040029e-07 1.843749e-07 6.705966e-07 9.486780e-07 7.000363e-07 1.044240e-07 2.283133e-08 1.122019 7.651131e-08 1.288436e-07 4.643313e-07 6.306424e-07 4.355093e-07 5.030170e-08 1.113803e-08 1.258925 5.657140e-08 9.000479e-08 3.162216e-07 4.110964e-07 2.582689e-07 2.184731e-08 5.046772e-09 1.412538 4.189784e-08 6.303173e-08 2.116831e-07 2.609904e-07 1.439485e-07 8.248525e-09 2.076775e-09 1.584893 3.101992e-08 4.430200e-08 1.392481e-07 1.590584e-07 7.390160e-08 2.484882e-09 7.342593e-10 1.778279 2.296954e-08 3.115300e-08 8.981495e-08 9.165721e-08 3.398118e-08 5.298457e-10 1.977418e-10 1.995262 1.704142e-08 2.177248e-08 5.649963e-08 4.947362e-08 1.350407e-08 7.167679e-11 3.391400e-11 2.238721 1.264929e-08 1.505059e-08 3.443747e-08 2.476773e-08 4.466445e-09 5.697627e-12 3.115956e-12 2.511886 9.352387e-09 1.029577e-08 2.022903e-08 1.125098e-08 1.193350e-09 2.539720e-13 1.360499e-13 2.818383 6.867887e-09 7.000544e-09 1.138417e-08 4.476159e-09 2.536314e-10 6.185001e-15 2.630710e-15 3.162278 5.002969e-09 4.761192e-09 6.081398e-09 1.497716e-09 4.276861e-11 8.130161e-17 2.164463e-17 3.548134 3.611948e-09 3.250972e-09 3.058913e-09 4.061340e-10 5.734689e-12 5.760169e-19 7.408980e-20 3.981072 2.582592e-09 2.218298e-09 1.454696e-09 8.663964e-11 6.115807e-13 2.246380e-21 1.321705e-22 4.466836 1.827746e-09 1.500083e-09 6.704670e-10 1.421899e-11 5.170542e-14 2.627524e-23 2.130316e-23 5.011872 1.279528e-09 9.998764e-10 3.115195e-10 1.766828e-12 3.448807e-15 1.751683e-23 1.420211e-23 5.623413 9.422543e-10 7.098246e-10 1.921113e-10 8.891352e-13 1.728106e-15 8.758413e-24 7.101054e-24 6.309573 6.049805e-10 4.197728e-10 7.270323e-11 1.144243e-14 7.404147e-18 0.000000e+00 0.000000e+00 Waterford (30.00° N, 90.47° E), Response Spectra Frequency (Hz)
UHRS 1E-4 (g)
GMRS (g)
UHRS 1E-5 (g) 0.500000 0.106226 0.122290 0.239879 0.561009 0.113745 0.126594 0.246231 0.629463 0.118443 0.128882 0.249273 0.706269 0.120596 0.132076 0.255863 0.792447 0.128148 0.138140 0.266552 0.889140 0.129957 0.139114 0.267963 0.997631 0.135755 0.146162 0.281945 1.000000 0.135949 0.146373 0.282353 1.122019 0.136944 0.149401 0.289146 1.258925 0.134208 0.150133 0.292389 1.412538 0.135411 0.153917 0.300959 1.584893 0.137639 0.158969 0.312080
1.778279 0.139693 0.164881 0.325446 1.995262 0.143001 0.171866 0.340771 2.238721 0.147478 0.179268 0.356458 2.500000 0.151673 0.187196 0.373642 2.805046 0.158807 0.199584 0.400176 3.147313 0.160701 0.207142 0.417967 3.531344 0.163652 0.214732 0.435213 3.962233 0.164446 0.214519 0.434148 4.445698 0.161207 0.211319 0.428191 4.988156 0.157302 0.212480 0.433785 5.000000 0.157261 0.212573 0.434051 5.610092 0.157117 0.213649 0.436900 6.294627 0.153062 0.209412 0.428890 7.062688 0.149145 0.207999 0.428041 7.924466 0.149721 0.208364 0.428566 8.891397 0.146868 0.206902 0.426860 9.976312 0.145196 0.203294 0.418774 10.000000 0.145183 0.203204 0.418549 11.220185 0.135361 0.190106 0.391905 12.589254 0.128494 0.179928 0.370650 14.125375 0.123069 0.171833 0.353719 15.848932 0.118585 0.164420 0.337867 17.782794 0.114428 0.157524 0.323118 19.952623 0.110801 0.151338 0.309819 22.387211 0.107971 0.146138 0.298494 25.000000 0.105546 0.140498 0.285784 28.050461 0.103811 0.135912 0.275311 31.473135 0.102978 0.132888 0.268213 35.313439 0.102691 0.130789 0.263112 39.622330 0.102427 0.129004 0.258799 44.456985 0.102706 0.128066 0.256272 49.881558 0.102873 0.127283 0.254213 55.968028 0.102523 0.126212 0.251758 62.797161 0.101381 0.124540 0.248290 70.459573 0.099404 0.122355 0.244055 79.056942 0.096459 0.119451 0.238622 88.703347 0.092624 0.115981 0.232335 99.526793 0.088696 0.112676 0.226528 100.000000 0.083129 0.106118 0.213604