Susquehanna (41.09° N, 76.15° E), Control Point Hazard SA (g)
AFE 0.5 Hz AFE 1 Hz AFE 2.5 Hz AFE 5 Hz AFE 10 Hz AFE 25 Hz AFE 100 Hz 0.001000 4.617096e-03 7.755986e-03 1.134984e-02 1.179109e-02 1.173100e-02 1.137516e-02 1.030314e-02 0.001122 4.279379e-03 7.304801e-03 1.103680e-02 1.163630e-02 1.164783e-02 1.122703e-02 1.003797e-02 0.001259 3.954414e-03 6.866806e-03 1.072618e-02 1.142880e-02 1.150752e-02 1.099835e-02 9.663547e-03 0.001413 3.638295e-03 6.427366e-03 1.037830e-02 1.118261e-02 1.130351e-02 1.074025e-02 9.268653e-03 0.001585 3.331108e-03 5.987516e-03 9.993973e-03 1.090483e-02 1.106477e-02 1.045980e-02 8.847748e-03 0.001778 3.033537e-03 5.550209e-03 9.572317e-03 1.059174e-02 1.080116e-02 1.015558e-02 8.404384e-03 0.001995 2.746891e-03 5.118388e-03 9.118723e-03 1.024496e-02 1.051142e-02 9.829216e-03 7.943384e-03 0.002239 2.472181e-03 4.694449e-03 8.634492e-03 9.864736e-03 1.019555e-02 9.482129e-03 7.470461e-03 0.002512 2.209533e-03 4.279430e-03 8.122853e-03 9.452487e-03 9.854409e-03 9.115453e-03 6.989128e-03 0.002818 1.960777e-03 3.876443e-03 7.589303e-03 9.010761e-03 9.489016e-03 8.731040e-03 6.505265e-03 0.003162 1.726438e-03 3.487443e-03 7.040066e-03 8.543698e-03 9.101261e-03 8.331464e-03 6.023531e-03 0.003548 1.508463e-03 3.115763e-03 6.483430e-03 8.056473e-03 8.693657e-03 7.919756e-03 5.549738e-03 0.003981 1.306550e-03 2.762295e-03 5.924452e-03 7.553734e-03 8.269134e-03 7.498606e-03 5.087293e-03 0.004467 1.122503e-03 2.430611e-03 5.373427e-03 7.041980e-03 7.831133e-03 7.071410e-03 4.640780e-03 0.005012 9.553322e-04 2.120648e-03 4.834011e-03 6.525929e-03 7.382940e-03 6.640932e-03 4.212487e-03 0.005623 8.063138e-04 1.835694e-03 4.316635e-03 6.012453e-03 6.928524e-03 6.210747e-03 3.805646e-03 0.006310 6.739114e-04 1.574753e-03 3.823186e-03 5.505882e-03 6.471378e-03 5.783589e-03 3.421487e-03 0.007079 5.586563e-04 1.340164e-03 3.362166e-03 5.012362e-03 6.015567e-03 5.362824e-03 3.061908e-03 0.007943 4.585728e-04 1.129898e-03 2.933134e-03 4.535049e-03 5.564339e-03 4.950712e-03 2.727066e-03 0.008913 3.733952e-04 9.451900e-04 2.541908e-03 4.078869e-03 5.121458e-03 4.550179e-03 2.417817e-03 0.010000 3.010897e-04 7.833940e-04 2.186331e-03 3.645872e-03 4.689742e-03 4.163096e-03 2.133643e-03 0.011220 2.409959e-04 6.445149e-04 1.869069e-03 3.239408e-03 4.272392e-03 3.791748e-03 1.874947e-03 0.012589 1.911409e-04 5.255615e-04 1.586655e-03 2.860193e-03 3.871570e-03 3.437333e-03 1.642120e-03 0.014125 1.506376e-04 4.257721e-04 1.339571e-03 2.510346e-03 3.489825e-03 3.101657e-03 1.432618e-03 0.015849 1.177957e-04 3.420847e-04 1.123578e-03 2.189254e-03 3.128454e-03 2.785064e-03 1.244570e-03 0.017783 9.167503e-05 2.732321e-04 9.375486e-04 1.897678e-03 2.789179e-03 2.490515e-03 1.076972e-03 0.019953 7.089660e-05 2.167194e-04 7.777462e-04 1.634630e-03 2.472749e-03 2.217665e-03 9.283625e-04 0.022387 5.462552e-05 1.710936e-04 6.421802e-04 1.399833e-03 2.180166e-03 1.965509e-03 7.974943e-04 0.025119 4.189141e-05 1.342709e-04 5.272251e-04 1.191337e-03 1.911787e-03 1.733463e-03 6.826951e-04 0.028184 3.205021e-05 1.049721e-04 4.308498e-04 1.008440e-03 1.667871e-03 1.521430e-03 5.825657e-04 0.031623 2.444871e-05 8.169248e-05 3.501871e-04 8.487378e-04 1.447510e-03 1.328750e-03 4.956024e-04 0.035481 1.862944e-05 6.341654e-05 2.833962e-04 7.104977e-04 1.249616e-03 1.155018e-03 4.204633e-04 0.039811 1.417553e-05 4.905762e-05 2.281469e-04 5.914186e-04 1.072884e-03 9.992006e-04 3.557693e-04 0.044668 1.078492e-05 3.787338e-05 1.829299e-04 4.898532e-04 9.163612e-04 8.605163e-04 3.002987e-04 0.050119 8.203460e-06 2.916411e-05 1.459527e-04 4.036344e-04 7.785845e-04 7.377251e-04 2.528796e-04 0.056234 6.242226e-06 2.242681e-05 1.160325e-04 3.311229e-04 6.582940e-04 6.298157e-04 2.124780e-04 0.063096 4.752199e-06 1.721448e-05 9.184219e-05 2.704090e-04 5.538993e-04 5.354722e-04 1.781011e-04 0.070795 3.620029e-06 1.320069e-05 7.247916e-05 2.200001e-04 4.639979e-04 4.535655e-04 1.485339e-04 0.079433 2.759764e-06 1.011009e-05 5.698360e-05 1.783089e-04 3.870156e-04 3.827927e-04 1.233656e-04 0.089125 2.105300e-06 7.738577e-06 4.469727e-05 1.440788e-04 3.215580e-04 3.220226e-04 1.022369e-04 0.100000 1.607380e-06 5.918967e-06 3.495987e-05 1.160593e-04 2.661882e-04 2.700673e-04 8.453440e-05 0.112202 1.227950e-06 4.526004e-06 2.729899e-05 9.324081e-05 2.196386e-04 2.258999e-04 6.973624e-05 0.125893 9.388190e-07 3.459705e-06 2.127282e-05 7.471783e-05 1.806629e-04 1.884609e-04 5.738536e-05 0.141254 7.180970e-07 2.644501e-06 1.655849e-05 5.976205e-05 1.481620e-04 1.567472e-04 4.709198e-05 0.158489 5.495999e-07 2.021260e-06 1.287072e-05 4.771155e-05 1.211479e-04 1.299799e-04 3.852507e-05
0.177828 4.207308e-07 1.544857e-06 9.995410e-06 3.802965e-05 9.880335e-05 1.075298e-04 3.142441e-05 0.199526 3.221599e-07 1.180694e-06 7.754134e-06 3.026073e-05 8.041340e-05 8.878592e-05 2.555051e-05 0.223872 2.466197e-07 9.021169e-07 6.009804e-06 2.404031e-05 6.532844e-05 7.318062e-05 2.070504e-05 0.251189 1.887248e-07 6.890001e-07 4.652248e-06 1.906471e-05 5.297866e-05 6.021251e-05 1.671475e-05 0.281838 1.442796e-07 5.257803e-07 3.596530e-06 1.509006e-05 4.288688e-05 4.944900e-05 1.343799e-05 0.316228 1.101645e-07 4.007733e-07 2.775679e-06 1.191721e-05 3.465182e-05 4.052441e-05 1.075357e-05 0.354813 8.395648e-08 3.049641e-07 2.137971e-06 9.387785e-06 2.794298e-05 3.313760e-05 8.564523e-06 0.398107 6.382283e-08 2.315394e-07 1.642628e-06 7.373279e-06 2.248408e-05 2.703276e-05 6.784993e-06 0.446684 4.837057e-08 1.753050e-07 1.258522e-06 5.772262e-06 1.804739e-05 2.199489e-05 5.345489e-06 0.501187 3.651379e-08 1.322433e-07 9.607518e-07 4.501438e-06 1.444503e-05 1.784257e-05 4.185242e-06 0.562341 2.744727e-08 9.936440e-08 7.306596e-07 3.495928e-06 1.152454e-05 1.442554e-05 3.256139e-06 0.630957 2.051757e-08 7.427045e-08 5.529521e-07 2.701889e-06 9.160370e-06 1.161739e-05 2.515116e-06 0.707946 1.525423e-08 5.522790e-08 4.164122e-07 2.077603e-06 7.250902e-06 9.315481e-06 1.928645e-06 0.794328 1.125843e-08 4.078351e-08 3.115582e-07 1.588030e-06 5.712077e-06 7.432921e-06 1.466641e-06 0.891251 8.253906e-09 2.992119e-08 2.316496e-07 1.206316e-06 4.476116e-06 5.898411e-06 1.105918e-06 1.000000 5.996706e-09 2.175946e-08 1.708087e-07 9.096842e-07 3.486454e-06 4.651295e-06 8.259131e-07 1.122019 4.321485e-09 1.569749e-08 1.249508e-07 6.807877e-07 2.697640e-06 3.642299e-06 6.108108e-07 1.258925 3.079326e-09 1.119908e-08 9.042451e-08 5.048818e-07 2.071381e-06 2.829166e-06 4.464322e-07 1.412538 2.172351e-09 7.910439e-09 6.477803e-08 3.708516e-07 1.576990e-06 2.177643e-06 3.223508e-07 1.584893 1.510337e-09 5.506912e-09 4.573961e-08 2.691780e-07 1.188586e-06 1.657835e-06 2.293252e-07 1.778279 1.035466e-09 3.780058e-09 3.183628e-08 1.927983e-07 8.855066e-07 1.245783e-06 1.604048e-07 1.995262 6.956483e-10 2.542531e-09 2.171109e-08 1.357643e-07 6.505004e-07 9.211507e-07 1.098514e-07 2.238721 4.570224e-10 1.672212e-09 1.446720e-08 9.365888e-08 4.696987e-07 6.673519e-07 7.323763e-08 2.511886 2.895584e-10 1.060517e-09 9.290700e-09 6.276067e-08 3.316061e-07 4.701478e-07 4.698577e-08 2.818383 1.744766e-10 6.395916e-10 5.669497e-09 4.037295e-08 2.270709e-07 3.182261e-07 2.847106e-08 3.162278 1.084676e-10 3.977588e-10 3.542483e-09 2.659057e-08 1.585177e-07 2.159332e-07 1.742731e-08 3.548134 4.245858e-11 1.559260e-10 1.415469e-09 1.280820e-08 8.996447e-08 1.136404e-07 6.383571e-09 Susquehanna (41.09° N, 76.15° E), Response Spectra Frequency (Hz)
UHRS 1E-4 (g)
GMRS (g)
UHRS 1E-5 (g) 0.500000 0.017087 0.022685 0.046112 0.561009 0.018877 0.025364 0.051713 0.629463 0.020734 0.028043 0.057268 0.706269 0.022659 0.030733 0.062807 0.792447 0.024634 0.033446 0.068369 0.889140 0.026671 0.036198 0.073987 0.997631 0.028775 0.039001 0.079690 1.000000 0.028819 0.039059 0.079808 1.122019 0.032160 0.044742 0.092019 1.258925 0.035733 0.050435 0.104102 1.412538 0.039491 0.056159 0.116135 1.584893 0.043423 0.061941 0.128191 1.778279 0.047507 0.067812 0.140364 1.995262 0.051747 0.073791 0.152703 2.238721 0.056149 0.079917 0.165301 2.500000 0.060506 0.085988 0.177791 2.805046 0.066584 0.096784 0.201243
3.147313 0.073398 0.108419 0.226345 3.531344 0.080893 0.120791 0.252859 3.962233 0.088996 0.133845 0.280686 4.445698 0.097992 0.148078 0.310904 4.988156 0.108147 0.163818 0.344159 5.000000 0.108368 0.164158 0.344875 5.610092 0.117579 0.180987 0.381757 6.294627 0.128023 0.199693 0.422613 7.062688 0.139578 0.220046 0.466926 7.924466 0.151938 0.241514 0.513539 8.891397 0.164331 0.262728 0.559453 9.976312 0.176372 0.282907 0.602916 10.000000 0.176623 0.283323 0.603811 11.220185 0.176995 0.285912 0.610394 12.589254 0.176450 0.287147 0.614167 14.125375 0.175514 0.287861 0.616896 15.848932 0.175227 0.289764 0.622251 17.782794 0.176716 0.294771 0.634377 19.952623 0.180213 0.303301 0.654193 22.387211 0.185760 0.315571 0.682252 25.000000 0.189386 0.321795 0.695740 28.050461 0.190299 0.323215 0.698742 31.473135 0.189421 0.321561 0.695077 35.313439 0.188085 0.319305 0.690207 39.622330 0.185039 0.314189 0.679178 44.456985 0.180116 0.305889 0.661269 49.881558 0.173059 0.294194 0.636142 55.968028 0.163269 0.277730 0.600639 62.797161 0.151095 0.257205 0.556349 70.459573 0.137665 0.233809 0.505455 79.056942 0.123244 0.208427 0.450103 88.703347 0.110387 0.185992 0.401282 99.526793 0.099392 0.167286 0.360825 100.000000 0.090327 0.152084 0.328065