ML20244C361

From kanterella
Jump to navigation Jump to search

Forwards Resident Inspector 820316 Memo Identifying Deficiencies in Tech Spec 3.3.b.2 Re Containment Cooling Sys Operability.Licensee Should Submit Tech Spec Change Request.Concerns May Be Generic to Plants W/O STS
ML20244C361
Person / Time
Site: Kewaunee, 05000000
Issue date: 04/15/1982
From: Streeter J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Varga S
Office of Nuclear Reactor Regulation
Shared Package
ML16342B348 List: ... further results
References
FOIA-87-121 TAC-49882, NUDOCS 8306280037
Download: ML20244C361 (1)


Text

~

. p.ug'o '

UNITE D STATES f

NUCLEAR REGULATORY COMMISSION l' k g ((,'t

8

)

.S.$

REGION lll k

,v 799 noosrVELT ROAD cLEN ELLYN,lLLINois 60137 q.....

APR 151982 MEMORA,NDUM'FOR:

S. A. Varga, Chief, Operating Reactors Branch 1, Division of Licensing, NRR FROM:

J. F. Streeter, Chief, Projects Branch 2, DPRP

SUBJECT:

KEWAUNEE CONTAINMENT COOLING SYSTEM OPERABILITY The attached memorandam from the Kewaunee Resident Inspettor identified l

deficiencies in Kewaunee's Technical Specification 3.3.b.2, which allows less conservative operation than the FSAR requirements. The attached letter from R. A. Clark'(NRR) to Sol Burstein (WEPCO) addresses similar concerns for the Point Beach Nuclear Plant.

Please develop modified Technicol Specifications for the Kewaunee Nuclear Plant and request the licensee to submit a Technical Specification change reouest.

Additionally, these concerns may be generic to other. facilities which do not have standard Technical Specifications.

If your staf f needs any additional information related to this subject, l

please contact Bill Fitzpatrick directly.

l 4p1.

J-----

J. F. Str(eter, Chief Projects Branch 2 Attachnents:

1.

Meme did 3/16/E2, E. E. Fitzpatrick to J. E. Konklin 2.

Lir dtd 2/10/82, R. A. Clark to Sol Eurstein cc w/ attach:

B. E. Fitzpi. trick, RI, kewaunee Site R. Licciardo, ORB 1[ M. ber ded'or W. Butler, CSB CONTACT:

B. Fitzpatrick

/

414-388-3120

$36 GASoo 3

.Xh

9.,

UNITE D STATES

/ g NUCLEAR REGULATORY COMMISSION s

1

...E WASHINGTON,0. C 20555

.Y' f

3 4.....

March 7,1983 Docket No.50-30L

~~

~~

Mr_. C. W. Giesl er,

~

Vice President - Nuclear Power Wisconsin ~ Public Service Corporation Post Office Box 1200 Green Bay, Wisconsin 54305

Dear Mr. Giesler:

A review of the Technical Specifications for the Kewaunes Nuclear Power

\\

Plant revealed a deficiency in regard to containment cooling system operability.

Enclosed is our evaluation of the Kewaunee Nuclear Power Plant Technical Specifications and a proposed. correction for your guidance, Please review your. Technical Specifications and, if you agree with our evaluation, propose an amendment to correct the deficiency.

You should complete 'the review of the Technical Specifications for the Kewaunee. facility and propose an amendment within 60 days from the date of i

this letter, The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance. is not required.

under P.L.96-511.

3 I

Sincerely,

)

\\en d M L Fteven A. Varga, Chief Operating P,eactors Er'nc (1

Division of Licensing

Enclosure:

As stated t

cc w/ enclosure:

See next page

  • m.

W

s ENCLOSURE 3 j

~.

NON-STS PWRS TO RECEIVE REVIEW OF CONTAINMENT COOLING TECHNICAL SPECIFICATIONS Facility Project Manager i

Indian Point 2 ORBfl - m n P.S'/4 Indian Point 3 ORB!l - J. Th x F. A /

  • Robinson 3 ORBil - G. Requa i

Surry 1 & 2 ORBfl - D. Neighbors i

Turkey Point 3 & 4 ORBf1 - E-ScrAvis d '"' k" Zion I & 2

. ORBtl -W4 ;4M-ef, T.A'u r,5 t

Ft. Calhoun ORSt3 - E. Tourigny Maine Yankee ORBt3 - C. ' elson K. de,7 e ' '

Prairie 1sland 1-& 2' ORBt3 - D. Dilanni Arkansas 1 ORBt4 - G. Vissing Oconee 1, 2 & 3 ORBf 4 - P. !?:gr.cr --

4 6c> n a

Rancho Seco ORBf 4 - M. i'e n. err E N<ner IMI-1 ORBf 4 - RNacotis~' J. ib W'M Big. Rock Point ORBf5 - R. Emch Ginna ORBt5 - Griyuus-G Haddam Neck-ORBt5 - G. Troef F E r 4 **' "

Palisades ORSf5 - T. War 6ach 4.

San Onofre 1 ORBf5 - W. Paulson i

Note:

Point Beach 1 & 2 previously reviewed.

Kewaunee being reviewed 4y g pursuant to this TIA.

l J

)