)W NO.98 f f
pg 2 s 19M MEMDRANDUM FOR:
R. C. Lewis, Director, Division of Resident and Pro,iect Programs, Region II FROM:
Uldis Potspovs, Chief Vendor Programs Branch, Division of Vendor & Technical Programs, Region IV
SUBJECT:
CLOSE0UT OF AITS Mo. F02700167 - CRACKED SPHERICAL WASHERS AND STUDS IN TRANSAMERICA DELAVAL GRAND GULF DIESEL GENERATOR CYLINDER During a vendor inspection at the Engine and Compressor Division of Trans-america Delaval, it was detennined that adequate corrective actions and s
preventive measures had been taken. Details are covered in the attached Vendor Programs Report No. 99900334/82-01.
We consider this action item closed; please contact us if you have any questions.
origin i sisned bx5 U. POTAPCNs
Uldis Potapovs. Chief Vendor Programs Branch cc:
K. V. Seyfrit R. L. Baer, IE R. F. Heishman, IE W. E. Foster, IE 8612120212 861203 PDR FOIA PDR ELLI596-656 bec:
J. T. Collins RIV gg SC:R& CPS BC:VPB CI:R& CPS W t.t os t.er/ rT toort t:d vrucapuv5
" >......... 3/[f./ 82........... 3 /.O
- 82.........,3/..../ SR...,,,,,,,,,,,,
,v=,...e)...........
)
.............p..
DATEf
~2c roau sie no o,sacu erdo OFFICIAL RECORD COPY I