Category:MEETING MINUTES & NOTES--CORRESPONDENCE
MONTHYEARML20206C8331999-04-26026 April 1999 Summary of 980929 Meeting with Texas Utilities Electric Co Re Licensing Submittals Requesting Exemption to App K & Topical Rept Submitted in Support of Exemption Request .List of Attendees Encl ML20236X4431998-08-0505 August 1998 Summary of 980814 Meeting W/Util Re Use of Caldon Leading Edge Flow Meter for App K Exemption & Power Uprate License Amend on 980714.List of Meeting Attendees Encl ML20198H4361997-12-24024 December 1997 Summary of 971112 Meeting W/Util at NRC Ofcs to Discuss 970228 Responses to 960522 Cable Functionality Safety Evaluation.Licensee Briefly Described Revised Response to Open Item Re Fire Stops.List of Attendees Encl ML20141H9291997-07-30030 July 1997 Summary of 970717-18 Meeting W/Tue Representatives in Glen Rose,Texas Re Licensee Proposed risk-informed Inservice Testing Program.List of Attendees Encl ML18065B0401996-11-0505 November 1996 Summary of 961016 Meeting W/Utils in Rockville,Md Re 10CFR50.46 Large Break loss-of-coolant Accident Evaluation Model Error & Changes.W/List of Attendees & Handouts ML20129B5921996-10-16016 October 1996 Summary of 961016 Meeting W/Util in Rockville,Md Re License Amend Request 96-005,inverters & Battery Chargers Mod ML20058J0961993-11-29029 November 1993 Summary of 930920 Meeting W/Util Re Results of Thermo-Lag Tests for Facility Fire Barrier Configurations ML20058F4501993-11-26026 November 1993 Summary of 931006 Meeting Re Possible Implementation of Improved Standard Ts.List of Attendees Encl ML20059K3131993-11-0505 November 1993 Summary of Operating Reactors Events Meeting 93-42 on 931103 ML20079R4171993-08-16016 August 1993 Trip Rept of 930718-22 Visit to Omega Point Lab,San Antonio, Tx Re Thermo-Lag Fire Barrier Test Program for Comanche Peak Steam Electric Station,Unit 1 ML20057E4861993-08-0606 August 1993 Trip Repts of NRC Observation of Thermo-Lag Fire Barrier Test Specimen Const by Util for Qualification of Thermo-Lag Fire Barriers Installed in Facility & NUMARC for Generic Qualification of Thermo-Lag Fire Barriers in Industry ML20056D9841993-05-18018 May 1993 Summary of Operating Reactors Events Meeting 93-17 on 930512 ML20128K0041993-02-11011 February 1993 Summary of 930107 Meeting W/Utils in Rockville,Md to Provide Forum for Licensees to Present Staff W/Info Re Design, Operational & Testing Experience & Justification for long- Term Operability of Alternate Min Flow Path ML20126M2191993-01-0606 January 1993 Summary of 921217 Meeting W/Util Re Findings from Fire Protection Insp on 921116 & Related Fire Protection Issues. List of Attendees & Handouts Encl ML20128D1731992-12-0202 December 1992 Summary of 921027 Meeting W/Util in Rockville,Md to Discuss Fire Barrier Acceptance Criteria ML20034D5811992-11-25025 November 1992 Trip Rept of 921116 Visit to Omega Point Labs to Witness Fire Endurance Test of Thermo-Lag 330-1 Fire Barrier for Licensee ML20034D5831992-11-13013 November 1992 Trip Rept of 921103-06 Visit to Omega Point Labs Re Fire Endurance Tests of Thermo-Lag 330-1 Fire Barriers for Licensee ML20079Q9161992-06-0808 June 1992 Trip Rept of 920506-08 Visit to Omega Point Labs,San Antonio,Tx Re Construction of Thermo-Lag Fire Barrier Test Specimens to Be Tested by TU Electric Against 1 H Fire Endurance Criteria ML20034D5891992-06-0808 June 1992 Trip Rept of 920506-08 Visit to Omega Point Labs to Observe Const of Thermo-Lag Fire Barrier Test Specimens to Be Tested by Licensee Against 1 H Fire Endurance Criteria ML20126J7941992-01-0404 January 1992 Summary of Meeting W/Util Re Pressurizer Surge Line leak- before-break Analysis ML20058N9711990-08-0909 August 1990 Summary of Operating Reactors Events Meeting 90-20 on 900808 ML20043A6411990-05-16016 May 1990 Summary of 900131 Meeting W/Util in Rockville,Md Re Facility Markups to Final Draft Tech Specs.Proposed Agenda,List of Attendees & marked-up Tech Specs Encl ML20043A1611990-05-15015 May 1990 Summary of 900507 Meeting W/Util in Rockville,Md Re Plans for Future Updates of Figures & Tables in Fsar.List of Attendees & Slides Used in Presentation Also Encl ML20012E7971990-03-23023 March 1990 Summary of 900321 Meeting in Arlington,Tx Re Util Briefing on Cygna Independent Assessment Program,Comanche Peak Response Team & Corrective Action Program.List of Attendees & Viewgraphs Encl ML20012C4011990-03-15015 March 1990 Summary of Operating Reactors Events Meeting 90-07 on 900314.List of Attendees Encl ML20011F6111990-02-28028 February 1990 Summary of Operating Reactors Events Meeting 90-05 on 900228 ML20006E7251990-02-12012 February 1990 Summary of Operating Reactors Events Meeting 90-03 on 900207.List of Attendees & Viewgraphs Encl ML20005E8421989-12-27027 December 1989 Summary of Operating Reactor Events Meeting 89-045 on 891227.List of Attendees & Significant Elements Discussed Encl ML20005D8121989-12-18018 December 1989 Summary of Operating Reactors Events Meeting 89-044 on 891213.List of Attendees & Viewgraphs Encl ML19332G0601989-12-0707 December 1989 Summary of Operating Reactors Events Meeting 89-43 on 891206.On 891128,high Cycle Fatigue Failure of Master Connecting Rod Assembly Occurred at South Texas,Unit 2.RHR Leakage Noted on 891201 at Braidwood,Unit 1 ML20005D6871989-12-0101 December 1989 Summary of Operating Reactors Events Meeting 89-042 on 891129.List of Attendees & Viewgraphs Encl ML19332D2821989-11-16016 November 1989 Summary of Operating Reactors Events Meeting 89-040 on 891115 ML19327C0541989-11-0202 November 1989 Summary of 891019 Meeting W/Sys Energy Resources,Inc, Louisiana Power & Light & Arkansas Power & Light Re Antitrust Concerns W/Consolidation of Operations Under Entergy Operations,Inc.List of Attendees & Viewgraphs Encl ML19325E8981989-11-0101 November 1989 Summary of Operating Reactors Events Meeting 89-38 on 891101 to Brief Senior Managers from Nrr,Aeod,Res,Region Ofc & Commission on Selected Events That Occurred Since 891018 Meeting.List of Attendees Encl ML19325E1761989-10-24024 October 1989 Summary of Operating Reactors Events Meeting 89-37 on 891018.List of Attendees & Events Briefing Encl ML19325D9211989-10-19019 October 1989 Summary of 891012 Meeting W/Sys Energy Resources,Inc, Arkansas Power & Light,Inc & Louisiana Power & Light,Inc at NRC Headquarters to Discuss Consolidation of Operations Under Entergy Operations,Inc.List of Attendees Encl ML20247R0161989-09-21021 September 1989 Summary of Operating Reactors Events Meeting 89-34 on 890920 to Brief Senior Managers & Regional Offices on Selected Events That Occured Since Last Meeting ML20247E3641989-09-0606 September 1989 Summary of 890717 Meeting W/Numarc,B&W Owners Group & Representatives of Lead Plants Re Status of STS Amends & Outstanding Issues Associated W/Lead Plant STS Submittals ML20247D5291989-09-0505 September 1989 Summary of Operating Reactors Events Meeting 89-31 on 890830.Significant Event for Input Into NRC Performance Indicator Program Identified ML20246K2171989-08-24024 August 1989 Summary of Operating Reactors Events Meeting 89-30 on 890823 Re Reactor Trip W/Multiple Instrumentation & Equipment Failures at DC Cook Unit 2 on 890814 & Auxiliary Feedwater Flows at Hb Robinson ML20247K2471989-08-24024 August 1989 Trip Rept of Staff 890718-19,21 & 0801-02 Visits to Nuclear Power Plants to Gather Info Re Industry Actions to Address Loss of Oil Malfunctions of Rosemount Models 1153 & 1154 Transmitters ML20245L2621989-08-0909 August 1989 Summary of 890801 Meeting W/Util in Rockville,Md Re Util Proposed Responses to NRC 890711 Request for Addl Info on Plant Operations QA Program.W/Related Info,Including Request for Addl Info,Draft Responses to Questions & Attendee List ML20248B5171989-08-0303 August 1989 Summary of 890725 Interface Meeting W/Util in Birrmingham,Al Re Sonopco/Util Corporate Organization Including Generic Activities & Initiatives Re Plants.Agenda & Viewgraphs Encl ML20245G5421989-08-0303 August 1989 Summary of Operating Reactors Events Meeting 89-28 on 890802.List of Attendees,Events Discussed & Significant Elements of Events & Summaries of Reactor Scrams for Wks Ending 890723 & 30 Encl ML20247K8451989-07-20020 July 1989 Summary of 890710 Meeting W/Licensee in Arlington,Tx to Discuss Options Re Evacuation of Site Personnel During Upcoming Emergency Preparedness Exercise ML20246P7771989-07-13013 July 1989 Summary of Operating Reactors Events Meeting 89-26 on 890712.Events Discussed & Significant Elements of Events Presented in Encl 2.List of Attendees Also Encl ML18153B7971989-07-0606 July 1989 Summary of 890612 Meeting W/Util in Rockville,Md Re Plant Configuration Mgt Program.Informs That Goal of Program Is to Confirm That as-built Plants in Conformance W/Licensing Design Basis as Described in FSAR ML20246F8691989-06-22022 June 1989 Summary of Operating Reactors Events Meeting 89-24 on 890621.On 890615,potential Unmonitored Primary Coolant Release Path to Environ Discovered at WPPSS-2.On 890617,loss of Offsite Power Occurred at Brunswick,Unit 2 ML20245G6411989-06-15015 June 1989 Summary of Operating Reactors Events Meeting 89-23 on 890614.On 890607,multiple Electrical Distribution Sys Problems Occurred at Oconee,Units 1,2 & 3.On 890610,unit Power Signal Caused Scram ML20245F2221989-06-0808 June 1989 Summary of Operating Reactors Events Meeting 89-21 on 890531.List of Attendees & Related Info Encl 1999-04-26
[Table view] Category:TRIP REPORTS
MONTHYEARML20079R4171993-08-16016 August 1993 Trip Rept of 930718-22 Visit to Omega Point Lab,San Antonio, Tx Re Thermo-Lag Fire Barrier Test Program for Comanche Peak Steam Electric Station,Unit 1 ML20057E4861993-08-0606 August 1993 Trip Repts of NRC Observation of Thermo-Lag Fire Barrier Test Specimen Const by Util for Qualification of Thermo-Lag Fire Barriers Installed in Facility & NUMARC for Generic Qualification of Thermo-Lag Fire Barriers in Industry ML20034D5811992-11-25025 November 1992 Trip Rept of 921116 Visit to Omega Point Labs to Witness Fire Endurance Test of Thermo-Lag 330-1 Fire Barrier for Licensee ML20034D5831992-11-13013 November 1992 Trip Rept of 921103-06 Visit to Omega Point Labs Re Fire Endurance Tests of Thermo-Lag 330-1 Fire Barriers for Licensee ML20034D5891992-06-0808 June 1992 Trip Rept of 920506-08 Visit to Omega Point Labs to Observe Const of Thermo-Lag Fire Barrier Test Specimens to Be Tested by Licensee Against 1 H Fire Endurance Criteria ML20079Q9161992-06-0808 June 1992 Trip Rept of 920506-08 Visit to Omega Point Labs,San Antonio,Tx Re Construction of Thermo-Lag Fire Barrier Test Specimens to Be Tested by TU Electric Against 1 H Fire Endurance Criteria ML20247K2471989-08-24024 August 1989 Trip Rept of Staff 890718-19,21 & 0801-02 Visits to Nuclear Power Plants to Gather Info Re Industry Actions to Address Loss of Oil Malfunctions of Rosemount Models 1153 & 1154 Transmitters ML20154L1661988-05-10010 May 1988 Trip Rept of 880412-15 Mgt Team Visit to Plant Sites,Two Matls Licensees & Region I Ofcs.List of Team Members & Summary of Observations & Perceptions from Visit Encl.Info Deleted ML20196F9951988-02-24024 February 1988 Partially Withheld Trip Rept of 880209-11 Mgt Team Visit to Region V & San Onofre & Trojan Sites Re Integrated Assessment of Mgt Effectiveness Associated W/Regionalized NRR & NMSS Programs ML20236Q4351987-11-0606 November 1987 Trip Rept of 871007 Visit to Corporate Consulting & Development Co,Ltd,In Raleigh,Nc Re Static Tests of HVAC Ductwork ML20235F9851987-07-0101 July 1987 Trip Rept of 870623 Visit to Culver City,Ca Re Testing of Conduit Clamps at Anco Engineers,Inc.List of Meeting Attendees Encl ML20151W0041987-03-12012 March 1987 Submits After Trip Rept ML20209J3181986-09-0303 September 1986 Trip Rept of Attendance at 860821 Meeting in Arlington,Tx Re Util Plans for Plant Issues.Summaries of Observations Listed ML20147E8911986-08-20020 August 1986 Trip Rept of 860721-25 Visit to Plant to Observe INPO Accreditation Team Evaluation of Six Training Programs, Including Instrumentation & Control Technician,Mechanical Maint & Electrical Maint.List of Team Members Encl ML20213F8661986-07-31031 July 1986 Trip Rept of 860514-15 Site Visit Re Seismic Design Issues Concerning Cable Trays,Conduit Qualification,Hvac Concerns, CRD Return Lines,Ie Bulletins 79-14 & 79-02 & Nonessential Piping.Request for Addl Info Re Vermont Yankee Encl IA-86-778, Trip Rept of 860514-15 Site Visit Re Seismic Design Issues Concerning Cable Trays,Conduit Qualification,Hvac Concerns, CRD Return Lines,Ie Bulletins 79-14 & 79-02 & Nonessential Piping.Request for Addl Info Re Vermont Yankee Encl1986-07-31031 July 1986 Trip Rept of 860514-15 Site Visit Re Seismic Design Issues Concerning Cable Trays,Conduit Qualification,Hvac Concerns, CRD Return Lines,Ie Bulletins 79-14 & 79-02 & Nonessential Piping.Request for Addl Info Re Vermont Yankee Encl ML20206J6561986-06-23023 June 1986 Trip Rept of 860612 Training Session in Lacey,Wa Re Federal Radiological Emergency Response Plans & Meeting W/Utils & State of Wa Concerning Potential Emergency Preparedness Issues.Attendees Listed & Training Agenda Encl ML20210S4371986-05-21021 May 1986 Trip Rept of 860505-07 Site Visit to Attend Civil/Structural Issues Audit Meetings.Audit Attendee List & Agenda Encl ML20244D8391986-05-0707 May 1986 Trip Rept of 860415 Site Visit Re Demonstration for Ultrasonic Exam Procedure of Statically Cast Stainless Steel Primary Loop Welds.Issue of Preservice Ultrasonic Exam of Welds Resolved.Trip Repts by Inel & Bnwl Encl ML20244D8401986-04-22022 April 1986 Trip Rept of 860415 Site Visit Re Demonstration of Ultrasonic Exams Performed on Cast Stainless Steel Primary Piping Welds.Exam Procedure Appears to Meet or Exceed ASME Code Requirements.Written Procedure Not Available ML20140H4751986-04-0101 April 1986 Trip Rept of 851120-22 Site Audit of S&W Implementation of Project Procedure CPPP-8 for Piping & Pipe Supports.No Items of Noncompliance or Deviations Noted ML20154L9181986-03-0606 March 1986 Trip Rept of 851021-24 Site Visits Re Wrong Unit/Wrong Train Events to Determine Whether Simple,Low Cost Improvements Can Be Identified & Implemented IA-86-270, Trip Rept of 860219 Site Visit to Examine Problems Re Improperly Installed Cable Splices Used for Bunker-Remo Electrical Penetration Connections to Field Wiring.List of Attendees Encl1986-03-0606 March 1986 Trip Rept of 860219 Site Visit to Examine Problems Re Improperly Installed Cable Splices Used for Bunker-Remo Electrical Penetration Connections to Field Wiring.List of Attendees Encl ML20205K8111986-03-0606 March 1986 Trip Rept of 860219 Site Visit to Examine Problems Re Improperly Installed Cable Splices Used for Bunker-Remo Electrical Penetration Connections to Field Wiring.List of Attendees Encl ML20237C9681986-02-19019 February 1986 Trip Rept of Attendance at State of Il 860213 Meeting Re Training Session on NRC Incident Response Program & NRC Participation in 860408 Plant Emergency Exercise.List of Attendees & Partial Agenda Encl ML20153E3411986-02-18018 February 1986 Trip Rept of 851021-24 Site Visit Re QA Program Procedures. Results of Discussions Factored Into 860115 Memo ML20205J5411986-02-18018 February 1986 Trip Rept of 851021-24 Site Visit Re QA Program Procedures. Listed Personnel Contacted at Site.Results of Discussions Documented in 860115 Memo ML20137U7271986-01-29029 January 1986 Trip Rept 2201 of 860121 Visit to Robert L Cloud & Assoc,In Berkeley,Ca Re Participation in Facility Cable Tray Verification Program.Company Will Audit Cable Tray Tests Performed by Ebasco,Impell Corp & Anco ML20137U7791986-01-22022 January 1986 Trip Rept 2202 of 860122 Visit to Impell Corp in Walnut Creek,Ca Re Applicability of Slenderness Ratio Limit to Facility Cable Tray Hangers & Impell Design Criteria & Procedures.Viewgraphs Encl ML20210C0771986-01-17017 January 1986 Trip Rept 2200 of 860117 Site Visit Re HVAC Hanger Program Audit.Status of Licensee Steam Electric Station Seismic Qualification Rept of Seismic Category 1 Duct Work & Hangers Changed from Approved to Not Approved on 860121 ML20210B9781986-01-16016 January 1986 Trip Rept of 851202-03 Visit to Tera Ofcs in Bethesda,Md to Audit Documentation Supporting Initial Level of Homogeneity for Design Activities Review Procedure DAP-21 That Will Be Implemented to Validate Homogeneity ML20141H8551986-01-10010 January 1986 Trip Rept of 851112-15 Site Visits Re Wrong Unit/Wrong Train Events.Visit Conducted as Part of short-term Effort to Determine If Low Cost Improvements Can Be Identified & Implemented to Reduce Frequency of Events ML20197E2451985-12-18018 December 1985 Trip Rept of 851125 Visit to S&W Engineering Corp Re Audit of Nonseismic Piping Effects on Seismic Design Piping. Further Audit of Anchor Designs Required.List of Attendees & Related Info Encl ML20141C9661985-12-18018 December 1985 Trip Rept of 851009-10,15-17 & 28-31 Site Visits Re Methodology Used by Applicant/Contractor in Establishing Equipment Populations & Equipment/Work Processes Homogeneity ML20141K3731985-12-0505 December 1985 Trip Rept of 851126 Audit Discussions Per Slenderness Ratio Limitations for Hanger Type Supports.Ebasco Svcs,Inc Considering Adoption of Revised Procedure.Slenderness Ratios Should Be Used Only Where Uncertainties Exist ML20141K4031985-12-0202 December 1985 Trip Rept of 851118-22 Audit of Cable Tray Hanger Walkdown. Supports Walked Down & Noted Discrepancies Listed ML20141K3941985-12-0202 December 1985 Trip Rept of 851113-14 Visit to Corporate Consulting & Development Co,Ltd to Audit Ongoing Tests of Electrical Conduit Clamps ML20141K3761985-12-0202 December 1985 Trip Rept of 851011 Audit W/Util,Tera & Comanche Peak Response Team.List of Attendees Encl.Meeting Between Tera & BNL Consultants Will Be Held to Discuss Steam Generator Lateral Restraints ML20141K4841985-11-22022 November 1985 Trip Rept of 851025 Audit at S&W Ofcs in New York,Ny Re Piping & Pipe Support Effort.List of Attendees Encl ML20137G6351985-11-21021 November 1985 Draft Trip Rept 2178 of 851029-31 Site Visit Re Item Vii.C, Const Reinsp/Documentation Review Plan ML20138P7841985-10-24024 October 1985 Trip Rept of 850827-29 Site Visit W/Util & Contractors Re Witnessing of Unit 1 Cable Tray Supports Walkdown in Progress & Collection of Info Concerning New Allegations ML20141K1991985-10-22022 October 1985 Trip Rept of 851008 Visit to Gibbs & Hill Ofc in New York,Ny Re Audit of Adlpipe Computer Code Used in Piping Analysis. Allegation AP-26 Questioning Validity of Code Verification & QA Maint Unsubstantiated.Agenda Encl ML20141K2381985-10-22022 October 1985 Trip Rept of 851014-18 Site Visit Re Status of Comanche Peak Response Team Verification & Corrective Action Activities by S&W,Ebasco & Tera,Qa/Qc Const Verification Effort & Action Plan Implementation ML20141K4671985-10-11011 October 1985 Trip Rept of 850923-26 Site Visit W/Teledyne Engineering Svcs Re Audit of S&W as-built Verification Walkdown ML20141K4371985-10-11011 October 1985 Trip Rept of 850923-26 Audit of S&W as-built Verification Walkdown.Contingent Upon Acceptable Resolution Re Piping Run Geometry & Clearances,S&W Walkdown Well Documented & Easily Verifiable ML20141K2111985-10-11011 October 1985 Trip Rept of 851008 Visit to Gibbs & Hill Ofc Re Followup on Allegation A-26 That Adlpipe Computer Program Not Validated. Attendance List Encl ML20138A1201985-09-23023 September 1985 Trip Rept of 850617-20 Site Visits Re Reduction of Wrong Unit/Wrong Train Events at Facilities ML20141K1261985-09-10010 September 1985 Trip Rept of 850829-30 Visit W/Util & Teledyne at S&W Ofcs in New York,Ny Re Status of S&W Effort Concerning Design Adequacy Program for Plant Piping & Pipe Supports.Lists of Attendees,Agenda & Util Action Plan Encl ML20147E2301985-06-0303 June 1985 Trip Rept of 850420-22 Visit to Port Gibson,Ms,To Participate in Field Test of Draft Training Review Criteria & Procedures at Plant.Nrc Teams Observed Licensed Operator & Nonlicensed Operator Training ML20133B8781985-03-15015 March 1985 Trip Rept of 850315 Site Visit Re Presentation of Licenses to Senior Reactor Operators & Reactor Operators.Subjs Discussed During Visit Stated 1993-08-06
[Table view] |
Text
'/
UNITED STATES 3 85 NUCLEAR REGULATORY COMMISSION n
h"v.
- g. b, e y.z)]s WASHINGTON, D. C. 20555
- . g JAN 15 E85 '
Docket Nos.:-
50-445/446 l
l
. MEMORANDUM FOR:
- Darrell G. Eisenhut, Director 1
Division of. Licensing FRON:
' Vincent S. Noonan, Director j
Comanche Peak Project
SUBJECT:
NOVEMBER 14-16, 1984 TRIP REPORT
~
i TO COMANCHE PEAK On Thursday, November 15, 1984, I requested that Texas Utilities (TV) make available QA/QC inspectors in all disciplines from Comanche Peak Units 1 and 2 l
for discussions with myself and Annette Vietti, a project manager on my staff.
We met with approximately 70 QA/QC inspectors in groups of five to ten i
throughout the day. The purpose of the meetings was to emphasize to the
]
inspectors that the NRC must resolve.all safety concerns before either unit can be licensed. We also assured each group that any inspector having a safety concern could discuss it in confidence with the NRC staff and to' facilitate this opportunity, we would accept collect telephone calls. Ms. Vietti and I provided.them with our telephone numbers by handing out our business cards.
We also discussed with them the NRC's concerns regarding TU supervisory attitudes toward the QA/QC issues they had raised. We emphasized to them that the NRC will attempt.to ensure that TU adequately addresses all safety concerns identified by QA/QC inspectors.
Finally, we discussed with them the role of
. the NRC resident inspector in forwarding their concerns directly to me at NRC headquarters.
It is too soon to tell how effective the meetings were, although it was obvious to us that the inspectors appreciated the interest taken by NRC in fostering an attitude that will permit them to perform their important work
/P effectively.
In fact, one group, which voiced several concerns, then met with
& Herb Livermore, TRT QA/QC Group Leader, who will now follow up on a couple of
.f the concerns raised.
I That evening, three NRC staff members, three of our consultan'ts and myself l
assembled for a pre-arranged feedback interview with one of our primary l
allegers, A-3.
Although we waited a reasonable amount of time, alleger A-3 8606250168 860611 6
PDR FOIA I
GARDE 85-59 PDR 1
e
- - ~..,... -
z 1
JAN 151985 i
I Darrell G. Eisenhut did not appear, so we concluded the meeting after making a record of who had attended and noting'that the allege-did not attend. We will keep a file copy of the record and provide a copy to the alleger.
li,
/.
1 eu
.N nan, Director Comanche
'eak reject i
1' I
E 1
9 cc:
W. Dircks H. Denton E. Case j
H. Gagliardo R. Wessman c
1 S. Burwell J. Zudans R. C. Tang
)
R. Bangart j
R. Keimig L. Shao C. McCracken H. Livemore 4
e 1
4 n
l'r 1
P.
e
.t _ _ _
/..
' pung m
" 7. / N ", f (
4 jh UNITED STATES u
n NUCLEAR REGULATORY COMMISSION
- j WASHINGTON. D. C. 20555 g
$g +
,/
n i
FEB i 2 1985 t
l Dockets: 50-445/446 Texas Utilities Electric Company Skyway Tower 400 North Olive Street l
Lock Box 81 Dallas, TX 75201 M.D. Spence,P{esident,TUGC0 l
ATTN:
l
Subject:
Request for Information on Employee Survey
Dear Mr. Spence:
f The NRC Comanche Peak Intimidation Panel has identified the need for information about employeefsurveys conducted in 1979 and 1983, to determine the conditions under which these surveys were administered.
Please i
provide responses to the following questions to assist the panel in its evaluation effort.
n i
i 1.
What were employees told concerning the confidentiality of their responses, who would be seeing the results, and how the survey data would be used?
i
}
I s
2.
How were the suryeys introduced and passed out to employees?
i i
3.
Where and how did employees complete the surveys?
4.
What guidelines ere used by those transcribing employee responses?
l 5.
Howwerethecomhletedsurveysreturnedtomanagement.
A 6.
How were employees selected to participate?
F t
7.
Which organizational units and/or job categories were included and excluded from ths surveys and what criteria were used for this process?
i 8.
How many QC inspectors were employed at the plant when each of these twosurveyswerejtaken?
I, i
~2~
FEB t 2 1966 Please provide responses to me within ten working days of receipt of this letter.
i.
Sincerely, 1
)
/
i ector anche Pea Project cc:
J. Gagliardo B. Kaplan S. Treby 1
o 1
r P
/
e P
8 G
F e
e P
c8%>k UNITED STATES n
C NUCLEAR REGULATORY COMMISSION 3
j WASHINGTON, D. C. 20555 w
e 2 8 BBS MEMORANDUM FOR:
Vincent S. Noonan, Director Comanche Peak Project FROM:
Herbert Livermore QA/QC Group Leader Comanche Peak Technical Review Team
SUBJECT:
MEETING WITH UTILITY REPRESENTATIVE JOHN HANSEL I
Her'b Livermore and Clif Hale met with John Hansel (TVEC QA Issues Leader), and I
a member of his team on January 21, 1985, at 1:00 pm. Mr. Hansel wanted i
certain specifics regarding items in our January 8,1985, letter to TUGC0 concerning QA/QC. Areas discussed were:
Document Control As-built inspections Inspector qualifications and training l
Corrective actions and trending 10 CFR Part 50.55(e) reporting Valve disassembly and reassembly Fuel pool liner The information provided to Mr. Hansel was typical of the information provided during our January 17, 1985, meeting with the utility. Mr. Hansel was advised that all the details would be provided in the SSERs when they are compiled and issued.
7 b
He t Livermor j
QA/QC Group Leader Comanche Peak Technical l
Review Team cc: TRT Group Leaders R. Wessman l
IkMmnR L3U_F M T~ _____XA L,._.
_r
'...