Text
_
--e---
J..
l,
)
~'
l.
f.
i
=
l.
a*>
,.. i f i
i o
., ~
. REGISTRY.OF-RADIOACTIVE! SEALED SOURCES AND' DEVICES SAFET ~ EVALUATION.0F SEALED. SOURCE i,'
-y NO.:~NR-300-S-863-S DATE:
2.1fl998 1
_ AGE:1 OF 4 p
Q
. SEALED SOURCE TYPE: Radiograpli[Sb~urce Assembly i
cMODEL:
"D" Series-l MANUFACTURER / DISTRIBUTOR:
Gamma Industries, Inc.
P.O. Box 2543 Baton-Rouge, LA 70821 1
1 ISOTOPE:
MAXIMUM ACTIVITY:
' Iridium-192' 100 Ci (3.7.TBq)
LEAK TEST FREQUENCY:
~6 Months
' PRINCIPAL.USE:
(A) Industrial Radiography l
CUSTOM SOURCE:
YES X
NO l
~ 9810276160 981021 i
PDR-RC d
SSD PDR f
nu m u.J~r
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-300-S-863-S DATE:
PAGE 2 OF 4 SEALED SOURCE TYPE: Radiography Source Assembly DESCRIPTION:
The Model D series source assemblies are designed for use in the Sinco Testing Model DU-100P exposure device.
The third (last) character in the source model designation indicates the type of
{
connector; the "G". indicates the short (old) saf-t-key connector, while t's.e "R" indicates the radionics or "T-BAR" connector.
The source is singly encapsulated in either 304 or 316 stainless steel.
The seal weld may be performed using an end cap weld, or a side circumferential weld, either of which are accomplished using a heliarc welding technique.. Capsule wall thickness is maintained at a minimum of 0.030" (0.76 mm).
Those pigtails furnished with the "R"
connector use 3/32" (2.38 mm) diameter stainless steel-cables while those furnished with the "G" connector use 1/8" (3.18 mm) diameter.
Pigtail length tolerances are held to 11/16" (11.59 mm).
1 PROTOTYPE TESTING:
These sources have a classification of E32515 as described in ANSI publication N5.10-1968. The manufacturer states that prototype source assemblies have met the test criteria specified in the ANSI document.
QUALITY ASSURANCE AND CONTROL:
Each " pigtail" assembly is subjected to a 100 lb. ( 45.36 kg) pull' test prior to radioactive material insertion, and is subjected to a contamination wipe test after the material is sealed in the capsule.
If the wipe test indicates contamination, then a hot water bubble test will be performed.
I
.g-i
~
. REGISTRY OF' RADIOACTIVE SEALED SOURCES luiD DEVICES -
SAFETY: EVALUATION OF SEALED SOURCE l
NO.: NR-300-S-863-S.-
DATE':
kpp PAGE 3 OF 4 SEALED SOURCE TYPE: Radiography! Source Assembly LIMITATIONS AND/OR-OTHER CONSIDERATIONS OF USE:
"D" SERIES SELECTION CHART
'Model No.
~ Maximum Activity Source Changer Source Exposure Device Ci (GBq)
- D-1-G-Sinco DU-100P 100 (3,700)
C.4'or C 10 D-1-R Sinco DU-100P 100 (3,700)
C 4 or C 10
~D-2-R Sinco LD Unit 3 (111)
C 4 or C 10
. The source shall.be possessed and used by persons specifically licensed by the NRC or an Agreement State.
. Handling, storage, use, transfer, and disposal:
To be determined by the licensing authority.
j
. This registration sheet and the information contained within the references'shall not-be changed without the written consent of the NRC.
SAFETY ANALYSIS
SUMMARY
The Model
- D" Series source is no' longer manufactured or
-distributed by Gamma Industries, Inc. and Gamma Industries, Inc.
'is'no longer in business.
Therefore, the registration
' certificate is being converted to an inactive registration certificate.
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-300-S-863-S-
.DATE:
OCT 21 1998 PAGE 4 OF 4 SEALED SOURCE TYPE: Radiography Source Assembly
' SAFETY ANALYSIS
SUMMARY
'(Cont'd):
The source was originally approved for licensing purposes _by the Louisiana Divis, ion'of Radiation Control..'NRC-attempted to obtain
. copies of all-_information,. submitted by:the_ registrant in support of the evaluation.
However, NRC could not locate all the information.
Therefore,'no_' safety evaluation of the source was'
.. performed as part of! the conversion of'the certificate to inactive status.
ISSUING AGENCY:
U.S. Nuclear. Regulatory Commission
/
Date:
Reviewer:
/
90
[ John W.
Lubinski
'Date:
2 l 1998 Concurrence:
%#/d[d%w
'Michele L. Burgess
-l
. _.,