ML20154R648

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Radiographic Exposure Device for Model Gammatron 50-A.Certificate:NR-300-D-862-S
ML20154R648
Person / Time
Site:
(NR-300-D-862-S, SSD-98-58)
Issue date: 10/21/1998
From: Michele Burgess, John Lubinski
NRC
To:
Shared Package
ML20154R650 List:
References
SSD, NUDOCS 9810270127
Download: ML20154R648 (4)


Text

_..

.m t

.i

' REGISTRY OF' RADIOACTIVE SEALED SOURCES AND DEVICES l

SAFETY' EVALUATION OF DEVICE

NO.~NR-300-D-862-S DATE
OCT 2119ss PAGE i OF 4 DEVICE. TYPE:

Radiohraphic Exposure Device.

c.

MODEL:

Gammatron 50--A

/

~

MANUFACTURER / DISTRIBUTOR:

" Gamma Industries,.Inc.

P.O. Box 2543 Baton Rouge,: 'LA :70821 L

i:

L-SEALED SOURCE MODEL DESIGNATION:

Gamma In'dustries A-7-A'or A-7-G I'SOTOPE:

MAXIMUM ACTIVITY:

)

Cobalt-60 50 Ci (1.85 TBq) l Depleted Uranium Shielding, 91 kg (201 lb.-)

q l

LEAK TEST' FREQUENCY:

6 Months l

l PRINCIPAL USE:

(A) Industrial Radiography p

l' j

i L

CUSTOM DEVICE:

YES X

-NO l

4 i

D, l'

.9810270127 981021 4

PDR RC 4

SSD PDR lu

a REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE-NO.: NR-300-D-862-S DATE:

OCT 21 1998 PAGE 2 OF 4 DEVICE TYPE:

Radiographic Exposure Device DESCRIPTION:

The device consists of a depleted uranium shield and polyurethane filler enclosed in an 1/8" (3.18 nmi) steel housing constructed by rolling a right circular cylinder, and arc-welding two circular endpieces.

A zircaloy "S"

tube extends through the uranium shield.

At one end is a lock box through which the source pigtail' cable and male half of the quick disconnect-connect connector protrude.

The "A"

used in the suffix of the model number indicates a modified lock box.

The purpose of the change in the design of the lock box is primarily one of safety, which assures that the lock plunger cannot be depressed into the lock position without the source being in a shielded position.

It also requires that a connection be made before the source can be cranked out into the exposed position, since it is necessary to apply back pressure by use of the control cable to permit the plunger to be placed in an unlocked position.

The drive cable conduit (30 f t.

[9.14 m]

minimum) is threaded into the lock box after removing the protective screw cap.

The depleted uranium shield (approximately 201 lb. (91 kg]) is secured in place by two steel webs inside the steel cylinder.

l The casting is coated with approximately 1" (2.54 cm) of asbestos cement for fire protection of the uranium shield in the event that the device has to be opened with a torch; the polyurethane filler acts as a cushion between the casting and the housing.

The complete device is mounted on wheels which allows easy movement of the device.

The tires and supporting boss are welded to the device housing, and two (2) 1-1/2" (3.81 cm) lifting eyes are welded to the top of the device.

The outside exterior dimensions are 16" (40.64 cm) in diameter, by 12" (30.28'cm) high, excluding the handle and wheels.

a

-l REGISTRY.OE RADIOACTIVE SEALED-SOURCES AND~ DEVICES

'-SAFETY' EVALUATION.0F. DEVICE NO.: NR-300-D-862-S DATE:

CCT 2 J 1993 PAGE 3 OF 4 DEVICE TYPE:

Radiographic Exposure Device

LABELING:

4 The-device bears the manufacturers label which specifies the i

device contains 201-lb. (91 kg) of-depleted uranium.

The label j

also specifies the isotope, activity, date of calibration, source l

seal number and states, Danger, Do Not Handle, Radioactive i

Material, Notify Gamma Industries, Baton Rouge, Louisiana, or Civil Authorities'.

~

l CONDITIONS OF NORMAL USE:

The manufacturer furnishes an operating and. maintenance manual

~

which includes step-by-step instructions for using the exposure device.

This device is very similar in design to the Gamma

' Industries Century exposure device, the difference.being that the Gammatron 50A is-larger and more heavily shielded.

EXTERNAL RADIATION LEVELS:

The source within the device is-greater than 4" (10.16 cm) to the outer surface of'the device.

Utilizing a source containing

-36.0 Ci (1.33'TBq) of Cobalt-60, the'following dose rates were lobtained with a calibrated ionization chamber.

~

Surface Dose Rate L ource in Shielded Position Dose Rate 1 Meter from Surface S

(mr/hr) ( Sv/hr) (mr/hr) ( Sv/hr) i a) Lock box 72 720 1.9 19 b) Source tube connection 82 820 2.2 22 L

.c) Lifting eyes.

38 380 0.8 8

d) Outside surface 95 950 3.2 32 50 500 1.9 19 LIMITATIONS AND/OR'OTHER CONSIDERATIONS OF USE:

. Cobalt-60' source exchange by the licensee is permitted by 1

using a Gamma Industries C-8 source exchanger.

?

f p-

~

-s ii-y

~

l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-300-D-862-S DATE:

OCT 21 1998 PAGE 4 OF 4 i

DEVICE TYPE:

Radiographic Exposure Device LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE (Cont'd):

. The license for radioactive material should include Provisions for 201 lb. (91 kg) of depleted uranium.

  • The device shall be possessed and used by persons specifically11icensed by the NRC or an Agreement State.

. Handling, storage, use, transfer, and disposal:

To be determined by the licensing authority.

This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.

SAFETY ANALYSIS

SUMMARY

The Model Gammatron 50-A device is no longer manufactured or distributed by Gamma Industries, Inc. and Gamma Industries, Inc.

is no longer in business.

Therefore, the registration certificate is being converted to an inactive registration certificate.

The device was originally approved for licensing purposes by the Louisiana Division of Radiation Control.

NRC attempted to obtain copies of all information submitted by the registrant in support of the evaluation.

However, NRC could not locate all the information.

Therefore, no safety evaluation of the device was performed as part of the conversion of the certificate to inactive status.

ISSUING AGENCY:

U.S. Nuclear Regulatory Commission

//

Date:

OCT 21 1998 Reviewer:

4/4/

/ John W.

Lubinski Date:

Concurrence: 76/M7[mm Michele L.

Burgess

.