REGISTRY lOF RADIOACTIVE SEALED SOURCES AND. DEVICES
~ SAFETY EVALUATION OF SEALED SOURCE NO-: 1NR-300-S-875-S DATE:
OCT 21 1999 PAGE 1 OF 5
. SEALED SOURCE TYPE: Radiographic Source Assembly
,MODEL:
A-13-A MANUFACTURER / DISTRIBUTOR:
Gamma Industries, Inc.
P.0,. Box 2543 Baton Rouge, LA 70821 i
. ISOTOPE:
MAXIMUM ACTIVITY:
? Iridium-192 36 Ci (1.33 TBq) 1 LEAK TEST' FREQUENCY:
6 Months i
l 4
. PRINCIPAL USE:
(A) Industrial Radiography
~
' CUSTOM SOURCE:
YES X
NO
.'9810270323 981021 C
..c w..,.
~.
lt L
. REGISTRY OF RADIOACTIVE SEALED SOURCES'AND DEVICES l
, SAFETY EVALUATION 0F SEALED SOURCE NO. : NR -3 00-S-875-S
'DATE:
OCT 21 1993-PAGE 2 OF 5 SEALED SOURCE TYPE:. Radiographic Source Assembly DESCRIPTION:
The Gamma Industries Model A-13-A source assembly is: designed for Luserin the Gamma Industries Model 2-15SA exposure. device.
The active material is metallic-Iridium-192, singly encapsulated in type 304 or-316 stainless steel, using a heliarc_ welding
~
technique.
This source assembly-is a departure from the usual radiography source in that'it contains two (2) sources on a single pigtail, separated by a maximum distance of-four (4) inches (10.16 cm).
The source capsules' closest to the connector in;the assembly _usesla~ side-weld closure, and the source capsule furthest from the connector in the assembly.uses an end-cap closure.
The pigtail connector,. source capsules and locking ball are crimped to 1/8 inch (3.18 mm) stainless steel cable.
-LABELING:
The source capsules ~are_not large.enough to allow' direct labeling.
However, the exposure' device which contains the source capsules-is labeled; and for additional labeling information, please see the certificate of; registration andisafety analysis.
summary for the Gamma' Industries Model-2-15SA exposure device.
DIAGRAM:
See. Attachment 1.
CONDITIONS OF NORMAL USE:
The Gamma Industries Model A-13-A source assembly is intended for
-use only_in the Gamma Industries Model 2-15SA Industrial Radiography exposure devices.
Gamma emission is checked against a standard using an ion chamber.
A decay chart and source tag are supplied with each source, providing information concerning the activity and leak test results.
l:
!p k
L' REGISTRY-OF-' RADIOACTIVE SEALED SOURCES AND DEVICES L
' SAFETY EVALUATION OF SEALED SOURCE L
L
~NO.:-NR-300-S-875-S DATE2 OCT 211998 PAGE 3'OF 5 E
~
r i
SEALED SOURCE TYPE:~Radi' graphic Source Assembly _
o Ph0TOTYPEITESTING:
This' source assembly consists of a singly encapsulated universal
-end-weld. capsule and a singly encapsulated side-weld capsule on a l
single pigtail. :Both capsules have.an ANSI classification of 1
77E43515, as described in ANSI' publication N542-1977.
Based on prototype; test data, these, designs are expected to. retain containmentcintegrity under accident conditions likely to occur
'during normal use or transportation.
7
)
EXTERNAL RADIATION LEVELS:
E The-dose rate from unshielded source of iridium-192 is approximately'5.9 R/hr per curie at 1 ft (30.48 cm).
? QUALITY' ASSURANCE AND' CONTROL:
The manufacturer. maintains pigtail dimensional tolerances at
-11/16 inch (il.59 rmn).
Each source assembly is subjected to, and
.must-successfully pass with no visible distortion, a 200 pound (90.72.kg) pull test prior to insertion of radioactive material.
"After encapsulation,. afwipe test for contamination is made.
If
.the results are doubtful 'then a hot water bubble test is performed.
No source'is shipped,if; removable contamination s
-exceeds 0.005. microcurie ~(185,Bq).
LIMITATIONS AND/OR OTHER'CONSIDERhTIONS OF'USE:
'The.Model-A-13-A=shallsbe possessed and used by specific licensees of U.S$ NRC or AgreementiStates.
O
. These sealed source? designs shall not be subjected to environmental or other conditions'of useJwhich exceed ANSI
-classification 7.7E43515.
F l
f.
b
. ~. _
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE I
NO.: NR-300-S-875-S DATE:
OCT 21 1998 PAGE 4 OF 5 SEALED SOURCE TYPE: Radiographic Source Assembly
~
-LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE (Cont'd)-
. These sources shall.be leak tested.at intervals not to exceed six (6) months using techniques approved by the licensing authority and capable of detecting 0.005 microcurie (185 Bq) of removable contamination.
. The source assembly.is designed for use in the Gamma Industries Model 2-15SA exposure. device which shall be labeled in accordance with applicable regulations.
. Handling, storage, use, transfer, and. disposal:
To be determined-by the licensing authority.
j This registration' sheet and the information cortained within the references.shall not-be changed withoutithe written consent of the'NRC.
-SAFETY ANALYSIS 1
SUMMARY
The Model'A-13-A source is nollonger manufactured or distributed by Gamma Industries,.Inc. and Gamma Industries, Inc. is no longer in. business.
Therefore,- the registration certificate is being converted to an inactive registration certificate.
The' source was originally approved for licensing purposes by the
. Louisiana Division of Radiation Control.
NRC attempted to obtain copies of all information submitted by the registrant in support of:theLevaluation.
However, NRC could not 1ocate all the information.
Therefore, no safety evaluation of the source was
. performed'as part of the conversion of the certificate to
' inactive status, l
i
REFERENCES:
i The following supporting documents for the Model A-13-A are hereby incorporated by reference and are made a part of this registry document.
i I~
i REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE I
NO.: NR-300-S-875-S DATE:
PAGE 5 OF 5
-SEALED SOURCE TYPE: Radiographic Source Assembly REFERENCES (Cont'd)-
Information provided by Gamma Industries in correspondence dated April 11, 1980 and April 22, 1981.
ISSUING AGENCY:
U.S. Nuclear Regulatory Commission
,/
OCT 21 1998 d
Date:
Reviewer:
// py John'W. Lubinski
_I_dadd mYh%w Date:
Concurrence:
Michele L. Burgesh
.]
y R.EGISTRY.OF-RADIOACTIVEJSEALED SOURCES AND DEVICES SAFETY EVALUATION-OF SEALED.. SOURCE A
- NO. : - NR[3 00-S-87 5--S
.DATE:
. I ISSO
. ATTACHMENT l'
~
a I
s
'i i
.-' k,k
-)
i' l~
i e 7so-
'2.3 75 MAX :. j,'
n e7 I
"L h g *[ "y ? " '
u d.ms%w[._J^
44 TiG w eto e./
,v 1
i l
4
- if.
m
,