. J.y '

I}< '

IN-. _

,,e 5

]k

'" ' ^

t t

,~

IREGISTRYIOF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY' EVALUATION OF SEALED SOURCE:

-. NO. :.' NR-3 0'0-S-8 7 4 -S -

lDr E:

E 2 l I990

'PAGE 1 OF 5 l

~ SEALED SOURCE TYPE:. Radiography-Source MODEL:

PL-3, PL-4 1

MANUFACTURER / DISTR'IBUTOR:

Gamma ~ Industries, Inc.

o P.O.

Box 2543

+

Baton Rouge, LA 70821

i T

1

-j ISOTOPE:

MAXIMUM ACTIVITY:

i

-Iridium-192 100!Ci (3. 7 TBo'

')

Iridium-192' 200 Ci (7.4 TT.

LEAK' TEST FREQd?.NCY:

6-Months

):

~ PRINCIPAL'USE:

-(A) Industrial. Radiography

/

0 rCUSTOM' SOURCE:

'YES

=- X NO s

i

.{

..t(.,

J 1

E-t t

i

~

?

,y-9810270316 981021 F

PDR RC

, N,,.

i SSD PDR g

'A..

b i

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE OCT 21 1998 NO.: NR-300-S-874-S DATE:

PAGE 2 OF 5 SEALED SOURCE TYPE: Radiography Source DESCRIPTION:

The Gamma Industries Model PL-3 source assembly is designed for use in the Gulf Nuclear Model 10X exposure device.

The Gamma

. Industries Model PL-4 source assembly is designed for use in the l

Source Production and Equipment Company,. SPEC CHECK Model II exposure device and the Pittsburgh Testing Laboratory Model PTL j

125U and 230U.

Both sources are doubly encapsulated and constructed of Type 304 or Type 316 stainless steel using heliarc (TIG) welding.

The wall thickness is maintained at a-minimum of 0.30" (7.62 mm) and is provided with a threaded body for securing in the exposure device.

LABELING:

The source capsules are not large enough to allow direct labeling; however, the exposure device which contains the source capsule is labeled.

For additionalzlabeling information, precise

-refer to the particular exposure device in which the source is to be_used.

DIAGRAM:

See Attachment 1.

CONDITIONS OF NORMAL USE:

The PL-3 AND PL-4 series source assemblies are designed for use in the Gulf Nuclear Model 10X, SPEC CHECK II, and PTL Model 125U and 230U industrial radiography exposure devices.

PROTOTYPE TESTING:

The source has a classification of ANSI 77E43515 as described in 7WSI publication N542-1977.

The manufacturer states that prototype sources have met the test criteria specified in the

~.

,4 4

1:

I REGISTRY OFERADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE

~

' NO. : : NR-3 00-S-87 4-S

'DATE:

PAGE 3 OF 5 l

SEALED' SOURCE TYPE: Radiography Source-

~ PROTOTYPE TESTING 1(Cont'd):

ANSI document.

The source.also has an IAEA Certificate of Competent Authority Special Form' Radioactive Material

. Encapsulation Certificate Number-USA /0166/S Revision 1.

j

' EXTERNAL RADIATION LEVELS:

Theidose rate for Ir-192 is 5.9 R/hr per curie at l' (30.38 cm).

QUALITY-ASSURANCE AND CONTROL:

)

Each source;is wipe 1 tested after-the capsule is welded.

If the results.of~the leak' test ore doubtful, then a hot. water bubble test is conducted.- No source will be shipped.if removable contamination' exceeds 0.005 microcurie (185 Bq)..

Sourc'e activities'are checked against'a standard by using an ion-

' chamber.

A' decay chart.and source tag are supplied with each source, providing information concerning the activity and leak test results.

1 LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

The Model PL-3-and PL-4.shall be possessed and used by to specific licensees of United States Nuclear Regulatory l

+

. Commission.or Agreement States.

j i

l

These sealedLsource designs shall not be subjected to j

environmental or other. conditions of use which exceed ANSI-classification 77E43515.

L J+: These sources.shallLbe leak tested at intervals not to.

~!

O exceed six-(6)lmonths using-techniques approved by the licensing' authority and capable of detecting 0.0051 microcurie (185'Bq) of removable contamination.

4 6

w

___._,_.m N

P i

REGISTRY OF1 RADIOACTIVE SEALED SOURCES AND DEVICES' SAFETY' EVALUATION OF-SEALED. SOURCE NO.:fNR-300-S-874-S.

DATE:

PAGE 4 OF 5-ESEALED: SOURCE TYPE: Radiography. Source I

LIMITATIONS AND/OR~OTHER CONSIDERATIONS OF USE (Cont'd):

.LThe source. assemblies'are. designed for use in the Gulf Nuclear Model 10X,- Source Production and Equipment Model SPEC CHECK II, and Pittsburgh Testing Laboratory-Model PTL.

125U and 230U.

. Source exchange must be performed.in a hot cell.

Therefore, the device ~must be1 returned to the manufacturer for source exchanges.

. Haddling, storage, use, transfer, and^ disposal:

To be determined by therlicensing authority.

~

. This registration ~ sheet'and the information contained within the references'shal17not:be. changed'withoutithe written

. consent of-the NRC.

-SAFETY ANALYSIS ~

SUMMARY

The Models PL-3 and PL-4:s'ources are no longer manufactured or distributed'by Gamma Industries, Inc. and Gamma' Industries, Inc.

is no longer in business.

Therefore, the~ registration certificate is being converted to an inactive registration certificate.

~

'The' sources were originally approved for licensing purposes by the' Louisiana Division of Radiation Control.

NRC attempted to s

obtain copies of all.information submitted by the registrant in

, support of the' evaluation.

However,.NRC could not locate all the linformation.

Therefore, no safety evaluation of the sources was iperformed as part of the conversion of the certificate to

' inactive status.

5 i

I-L

~

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE I l39b NO.: NR-300-S-874-S DATE:

PAGE 5 OF 5 SEALED SOURCE TYPE: Radiography Source

REFERENCES:

The following supporting documents for the Models PL-3 and PL-4 are'hereby incorporated by reference and are made a part of this registry document.

Gamma Industries Drawings 801-8001-029 and 801-8013-801.

ISSUING AGENCY:

U.S.

Nuclear Regulatory Commission D 2 I 1998

~

Date:

Reviewer:

/ John W.

Lubinski Date:

Concurrence:

d Michele L.

Burgess l

l

L REGISTRY OF RADIOACTIVE SEALED' SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-300-S-874-S DATE: W 21 1998 ATTACHMENT 1 3/8-16 e. I '3 8 -+

c

g.,

L-- T

' o*

Uh r,

4 1/16 x 1/1 77 i

NOTES

+ 125*

1.

Source cavity diameter "C" is determined according to source size.

- 300 -

2.

"a"

= "A"+ 0.03125, "A"

determined by source

'.000 81***

010 3.

Wall thickness maintained at.030 inch minimum.

4.

"D" diameter of cap & capsule drill will vary according to source strength to a maximum of 0.180 inch.

5.

Material: 304 or 316 stainless steel 3/8 - 16 All Thread (456-7010-002) 6.

Source will be Heliarc (Tig) welded.

GAMMA INDUSTRIES 8.R. L A.

.. m

"'"' 11 7 9 t d(8 / /

      • '*" IPF 3/3/8' Use:

Source capsule for SPEC exposure device

.9 I SPEC Check model 2, PTL 125U. & PTim2300 l Add 2d to devices ub81.

Ub j

d in. IDL 4-h/ k 76 9rt.

was 801-8013-

~

del Description ite

[rpcI j$ihmateri1,No.ofC1.

L

____