PNO-II-85-116, on 851211,facility Shut Down to Repair Steam Generator Tube Leak & Correct Low Oil Level in Reactor Coolant Pump.Caused by Low Level Indication on Reactor Coolant Pump.Restart of Unit Scheduled for 851226

From kanterella
(Redirected from ML20138L912)
Jump to navigation Jump to search
PNO-II-85-116:on 851211,facility Shut Down to Repair Steam Generator Tube Leak & Correct Low Oil Level in Reactor Coolant Pump.Caused by Low Level Indication on Reactor Coolant Pump.Restart of Unit Scheduled for 851226
ML20138L912
Person / Time
Site: Mcguire
Issue date: 12/12/1985
From: Brownlee V, Dance H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
PNO-II-85-116, NUDOCS 8512200102
Download: ML20138L912 (1)


,

December 12, 1985 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE PN0-II-85-116 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verifi-cation or evaluation, and is basically all that is known by the Region II staff on this date.

FACILITY: Duke Power Company Licensee Emergency Classification:

McGuire Unit 2 Notification of Unusual Event Docket No. 50-370 Alert Cornelius, North Carolina Site Area Emergency General Emergency X Not Applicable

SUBJECT:

UNSCHEDULED SHUTDOWN LONGER THAN 48 HOURS Duke Power Company shut down McGuire Unit 2 yesterday to repair a steam generator tube leak and to correct a low oil level in one of the unit's reactor coolant pumps.

Duke had planned to take the unit out of service on December 15 to correct the steam generator leak, but advanced the shutdown time after the low oil level indication on the reactor coolant pump was received. At the time of the shutdown, the steam generator leak had reached 250 gallons a day, which is half the technical specification limit.

Restart of the unit is scheduled for December 26. McGuire Unit 1 is operating at 100 percent power.

Duke will announce this outage on its weekly plant status report which is made available to the media.

The State of North Carolina has been informed.

This information is current as of 11 a.m. (EST) today.

Contact:

H. C. Dance, 242-5533 V. L. Brownlee, 242-5583 DISTRIBUTION:

H. Street MNBB Phillips E/W Willste MAIL:

Chairman Palladino ID0- NRR TF NMSS IDRIN!B

-Comm. Roberts ; PA OIA RES D0T: Trans Only Comm. Asselstine MPA AE0D Applicable State Comm. Bernthal ELD Comm. Zech' Air Rights INP0 - 3 ' M SECY \ SP NSAC ACRS CA o$%2 f-~'l l /Oj T*'/l T PDR Regions: 7- / / d) --

Licensee: 3: So (Reactor Licensees)

Applicable Resident Site - 3'.45 8512200102 851212 h PDR I&E g PNO-II-85-116 PDR h