ML20085D086

From kanterella
Jump to navigation Jump to search
Errata Sheet 1 to Amend 10,Suppl 2 to License DPR-4,revising Safeguards Rept
ML20085D086
Person / Time
Site: Saxton File:GPU Nuclear icon.png
Issue date: 01/18/1963
From: Neidig R
SAXTON NUCLEAR EXPERIMENTAL CORP.
To:
Shared Package
ML20083L048 List: ... further results
References
FOIA-91-17 573, NUDOCS 9110150230
Download: ML20085D086 (2)


Text

.

\\

SAXTON NUCLE /J1 EXPERIMENTAL CORIVRATION 1

Application for Reactor Construction Permit and Operating License Docket No. 50-146 Amendment No.10 - Supplement No. 2 Errata Sheet No. 1 The following corrections and typographical errors pertain to Addendum No.1 to the Safeguards Report for Phase 1 of the Saxton Nuclear Experimental This Addendum, dated Corporation's Five-Year Research and DeveloIraent Program.was submitted with December 20,1962, Saxton license application on December 21, 1962.

On page 4 in the paragraph at the bottam of the page, I.

the subassembly referred to in the first sentence of this paragraph should be subassembly No.1 instead of subancembly No. 2.

On page 5 in the first paragraph under item b, "Nine-Rod II.

Subassembly No. 2," the core location given in the first sentence should be " location I" instead or " location III."

Replace " Table 11-1 Physical Data" vith the attached " Table l

III.

II-1PhysicalData" dated 1/16/63 SAXTON fiUCLEAR EXPERIhE!ML COPJtRATION By

/s/

R. E. Neidig President

/W Attest:

N i

'"l 7

/s/ R. E. Sypher Secretary Cy %E*l,.

,,Q (S E A L) w.>"

/

w 18th day of Sworn and subscribed to before me this January 1963 (S E A L)

/s/ Martin A. Kohr l

Notary,Public 0 910424 Muhlenberg Township, Iierks County-

$01 DEKOK91-17 PDR My Camission Expires Feb. 4,1966 e.,cn " "

573 x

TABLE II-1 PHYSICAL DATA

( All

  • dimension.n ncninal) 9-Rod 4-Poi Standard Subasse=bly Subassembly Assembly Stainless Clad Zircaloy Clad S+ m ess Clad No. of rods per subassembly 9

5 4

h

~

Active fuel length, in.

36.6 36.1 34.8 33 2 Red outside dia., in.

O.391 0 380 0-391 0 576 Clad thickness, in.

0.015 0.0095 0.0237 0.0235 Pellet dia., in.

0 35T 0 357 0 337 0 5h35 0.004 0.004 0.0065 0.009

    • Cold pellet-to-clad gap, in.

Pitch, in.

0 580 0 535 0 535 0 746 6.1 83 Enrichment,v/oU-235 5 69 l

Center subassembly enrichment = 5 69; O

peripheral subissembly enrichment given en pa6e 5

    • Diametral I

?

nevised1/16/63

__