AES C211352 Final Reoort APTECH engineering services,Inc

.uolueeRi~oCOusut1AN1.

795 SAN ANTONIO ROAD. PALO ALTO = CALIFORNIA 94303 (415)858 2863 4

s t

l ANALYSIS OF INACCESSIBLE AND POTENTIALLY REJECTABLE DEFECTS IN PERRY NUCLEAR POWER PLANT 1

Prepared by Warren P. McNaughton Geoffrey R. Egan Jeffrey D. Byron Aptech Engineering Services, Inc l'

795 San Antonio Road Palo Alto, California 94303 1

l Prepared for Gilbert Associates, Inc.

Post Office Box 1498

,t l

Reading, Pennsylvania 19603 Attention: Paul B. Gudikunst 8306080048 830531 PDR ADOCK 05000440 A

PDR May 1983 Services in Mechanical and Metallurgical Engineering, Welding, Corrosion, Fracture Mechanics, Stress Analysis

r QUALITY ASSURANCE VERIFICATION RECORD SHEET

Title:

Analysis of Inaccessible and Potentially Rejectable Defects in l

Perry Nuclear Power Plant i

Originated by:

/

8'86-83 N

Warren P. McNaughton MV. '

5-26.- %

v Jeff' rey D. Byron I

Verified by:

Mb Zlo Md 63

[effre o

Approved by:

F-2442 Geoffmy R. Egan s/B3 Quality Assurance Approval:

// [ b f

Mell C. Cipolla I

l I

n i

TABLE OF CONTENTS PAGE TITLE SECTION iii SYNOPSIS 1-1 1

INTRODUCTION 1-4 References 2-1 ANALYSIS METHODS 2-1 2

Fracture Mechanics Background 2-3 2.1 Linear Elastic Fracture Pkchanics 2-5 2.1.1 Elastic-Plastic Fracture Mechanics 2-6 2.1.2 Limit Load Analysis 2-7 2.1.3

' Summary of Fracture Mechanics Background 2-8 2.1.4 2.2 Fatigue Loading 2-8 Analysis Method 2-9 2.2.1 Crack Growth Rate Representation 2-10 2.2.2 References 3-1 ANALYSIS OF STRESSES 3-1 3'

3.1 Secondary Stresses 34 3.2 Primary Stresses 37 3.3

-Combined Stresses 3-14 References 4-1 FATIGUE CRACK GROWTH RATES 48 4

References 5-1 FRACTURE TOUGHNESS AND STRENGTH 5-1 5

5.1 Introduction 5-1 Fracture Toughness: Background 5-4 i

Toughness Values for Containment Welds 5.2 5-6 5.3 l

Crack Opening Displacement-(COD) Values 5-8 5.4 References 6-1 CHARACTERIZATION OF FLAWS 6-1 The Effect of Slag Inclusions on Structure Intcgrity 6

6-8 Defect Interaction and the Modeling of Defects l

6.1 6-11 Digital Enhancement Methods Used in the Present Analysis 6.2 6-12 6.3 Results of Flaw Characterization 6.4 7-1 RESULTS OF ANALYSIS 7-1 Results of the Linear Elastic Fracture Mechanics 7

7.1 (LEFM) Analysis 7.1 Indications in Seams 1-1 and 2-1 7-3 7.1.1 7.1.2 Weld 1-4

'F G

c

11 TABLE OF CONTENTS (Continued)

PAGE TITLE SECTION 7-3 7.1.3 Welds 1-7 and 1-9 7-3 Limit Load Analysis 7-6 7.2 Elastic-Plastic Fracture Mechanics (EPFM) Results 7-19 7.3 References 8-1 8

CONCLUSION AND

SUMMARY

A-1 APPENDIX A: Supplemental Toughness Data APPENDIX B: Background Information About Digital Imaging B-1 Techniques APPENDIX C: Details of Flaw Characterization Work C-1 D-1 APPENDIX D:

Controlled Documents

r i

SYNOPSIS This report summarizes the results of fracture mechanics and fatigue evaluations which were performed for the Perry Nuclear Power Plant Units 1 and 2.

These evaluations were performed for several regions of the containment structures as foilows:

u-e inaccessible locations in weld joints 1-1 and 2-1 which had weld Indications.

I i

e Three inaccessible weld locations In joints 1-4,1-7, and 1-9.

In these last three locations, incomplete radiographic information exists to establish the existing defect size (for example, whether or not fuli I

repairs were made); however, suf ficient data do exist to characterize the maximum extent of a defect that could remain in the structure and this potential defect has been analyzed.

The evaluations that were performed required three types of input data.

I These data were stresses, both applied and weld residual stresses, flaw l~

geometries and material properties.

Recently, revised stress data were supplied by Gilbert Associates for the containment. Bounding cyclical and steady state stresses were incorporated to provide an analysis that results in a conservative evaluation of the weld Indications. A conservative residual stress determination was also made by assessing the appropriate experimental data.

~

Flaw data were obtained from radiographic enhancement techniques performed

~

on supplied radiographs. These techniques were used to provide accurate l

11 t

sizing of the Indications. Such determinations remove some of the

~I l

conservatism which has traditionally been used to assess structures with defects in the absence of actual flaw size data.

Material properties such as strength, fracture toughness and crack growth rates were determined using available Certified Material Test Reports and by comparison to generic data obtained from the open literature.

The results confirm that crack growth by fatigue is small over the design plant lifetime, even assuming conservative stress levels, bounding initial flaws and worst case crack propagation rates.

Furthermore, it is shown that the applied stress intensity values reached during and af ter such growth are less than the critical value to cause structural failure. The conservative result of the linear elastic fracture mechanics methodology used in this work is then confirmed using both elastic-plastic and net section collapse (or limit load) methods.

It is shown that relatively long and deep flaws can be tolerated even with the conservative assunptions which have been made.

11 Section 1 INTRODUCTION

. A review of radiographs for the Perry Nuclear Power Plant Units 1 and 2, has found certain containment welds that contain potentially rejectable indications. The radiographs can be grouped into two logical regions of Interest.

The first group of weld Indications are found in radiographs associated with weld joints 1-1 and 2-1.

These weld locations are inaccessible. They are located in the containment wal l (see f igure 1-1) in double sided butt welds and are covered on the inside of the containment by a doubler plate.

Defects have been found that would be considered rejectable by ASME Boiler and Pressure Vessel Code criteria. Twenty-one radiographs of weld 1-1 and 43 radiographs from inaccessible regions of Unit 2 were reviewed.

The stresses in Units 1 and 2 are identical. Bounding defects were developed considering both Unit 1 and Unit 2 indications.

The second group of Indications consists of three specific weld locations

-In joints 1-4, 1-7 and 1-9.

Weld joint 1-4 has a defect at location i

(79-80) 11-12. which has been sized at 2 3/4" long and 1/16" in height.

It

,I appears to be a plate delsmination (CD-139, Attachment 4).

I

{

in weld joint 1-7, at location (110-111) 25-26, the film shows a questionable Indication.

If this location were accessible the disposition i

would be to grind and retake.

In addition, the film is in question because it does not cover the full Indication. At maximum, it would be a 9/16" long slag line (CD-139, Attachment 3).

f in weld joint 1-9, at location (134-135) 24-25, the film has no Indications however, the adjacent film did have repair which extended into this station. A slag inclusion may still be present, maximum length equal to 1 3/4" (C0-139. Attachment 3).

These locations are also inaccessible i

t i

y

---,..--r.+ev-

---r--

w----

v.,

e

---,---e-,.%- - - - - -, _ -, - - - - - - - - - -, - -, - - - - - - - -

y

}

1-2 Elev.

575'-10" i

Containment Shell (Inside Surface)

Doubler Plate

{

(Inside Surface)

Containment Shell (Outside Surface)

Doubler Plate (Outside Surface)

N Concrete Base Liner

/

Foundation Mat lev. 575'-1" Joint 1-1

/

Y'10.187" l.

i l

Figure 1-1 Typical Horizontal Weld Joint (1-1 shown here) l '.

l l

l l

l

l 1

1-3

,i s

and the existing radiographic Information can be used to provide worst case I

estimates of defect size remaining in the structure, or of the possible incomplete repairs.

All welds have been fabricated using E7018 weld metal. The defects are 4

completely contained in the weld metal except in joint 1-4 where the Indication is in the base material-SA516 Grade 70. The concern in each t

case is that the Indications if unrepaired, may lead to early structural failure. This report addresses that concern and does so by evaluating the potential for defect growth by a fatigue mechanism and concurrent or subsequent f ailure by fracture.

l The remainder of this report consists of six sections.

Section 2.0

' outlines the analysis methods that have been used to evaluate the defects.

The next four sections introduce and discuss input to the analytical model.

They are: the evaluation of stresses-both appiled and residual (Section 3.0). characterization of material properties (Sections 4.0 and 5.0), and results of the enhancement work perf ormed (Section 6.0).

Section 7.0 provides the results of the analysis performed. Conclusions and summary are provided in Section 8.0.

Throughout the report, reference is made to documents which have been used to provide input Information to the analysis. These documents which are considered controlled under the requirements of the Aptech quality assurance system are designated Controlled Document (CD) and are referenced in Appendix D of this report.

l l.

1-4 Section 1

.REFEREN S 1-1 American Society of Mechanical Engineers, Boller and Pressure Vessel Code, Section 111, 1974 Edition, Winter 1975 Addenda.

I

(

i c l.

.t l

l 1

r 2-1 t

t 1..

Section 2 ANALYSIS ETH00S

~

The foilowing sections discuss those aspects of fracture mecnanics and fatigue theory which were used in the analysis of the present problem. A presentation of general fracture mechanics background (2.1) !s foilowed by a discussion of-methods of analysis to assess f atigue growth (2.2).

I 2.1 Frac +ura behanics Emeknenunti The failure behavior of structures under monotonic (slowly increasing) loading can be classified into three regimes in which a specific type of failure mode is appropriate. These three regimes cover brittle fracture.

ductile fracture and plastic collapse. The disciplines required to assess these regimes are:

~

e Linear Elastic Fracture Mechanics (LEFM) - The structure fails i

~

in a brittle manner and, on a macro scale, the load to f ailure occurs within nominally elastic loading.

(

e Elastic-Plastic Fracture Mechanics (EPFM) - The structure falls in a ductlie manner, and significant stable crack extension by l,

tearing may precede ultimate failure.

e Fully Plastic Instability (Limit Load Theory) - The failure event is characterized by large deflections and plastic

~

strains associated with ultiinate strength collapse.

s A diagram that shows the relationship between critical or failure stress and flaw size for the three failure modes is given in Figure 2-1.

The shape and position of the failure locus will depend on the fracture l

toughness (K ) and strength properties (o ) of the material, as well l

Ic 4

as the structural geometry and type of loading.

4

. l l

?N ow A

T r

o F

ez i

S N

w

)

t a

fF l

P F

N E

d

(

)

n c

M a

N i

F t

E s

s L

s a

(

e N

r l

P e

t r

\\'

t S

N c

u

/

e i

t

\\

a t

c r

2 N

u s

a

\\

a r

l

\\\\

l F

i h

\\

a E

rN t

F p

\\

e n

\\

D g\\

e s

e w

w

\\

\\

a t

l e

d\\

F B

s e

r l\\

el l

p a

N i

u o\\

n h

t r o

s ct\\

i n

N an s

o ro n

i FC e

t m

a i

l D

e R.

g n

s N

o ee i

hd t

to N

M gne A

irwu ol hi U

Sa F

c

\\

ig tn ai mt d

ei

\\

ae hm ci o1

/

SL td l1 ia tr

\\

mo i

1 il mn L

2 i

LC e

r f'

u

.//,

,/ / /'

g i

F

$E

._ e f "

)

t i

.l 1

i

[

Li 2-3 1

1 2.1.1 Linear Elastic Fracture Mechanics (LEFM)

The principles of linear elastic fracture mechanics (LEFM) are applied to assess quantitatively the conditions for brittle fracture.

Brittle fracture consists of two separate events:

(1) the initiation of a crack, and (2) the subsequent propagation of the crack to complete failure.

Each of these events, initiation and subsequent propagation, has dif ferent characteristics. For ferritic structural steels of the SA516 type and l'

carbon manganese weld metal of the E7018 class, the resistance to a

~

propagating fracture is usually lower than the resistance to fracture l

Initiation under slowly applied loads. This is because steels of this type I

are sensitive to loading rate; the high loading rates associated with a running crack lead to higher yleid strength and, hence, lower values of fracture toughness.

In constant load situations, therefore, continued crack propagation is expected once the fracture has initiated. For this reason, no attempt is made to evaluate the characteristics of the propagating crack af ter it has initiated, and the criterion of fracture

~

Initiation is used as the definition of failure in the fracture analyses.

I Fracture initiation occurs at a defect when the crack driving force exceeds l

the material's inherent resistance to crack initiation, or fracture e

toughness. The crack driving force is a function of the stresses acting on l

the defect and the geometry of the defect. The stresses which act on the defect include both primary (applied) stresses and secondary (Internal) stresses. Examples of secondary stresses are residual stresses and thermal stresses that are in equilibrium across the section. The manner in which a structure wilI fall wilI be determined by the interaction of the defect geometry, loading. and material toughness.

l In linear elastic fracture mechanics, the most usef ul parameter for characterizing the behavior of cracks is the stress intensity factor K,

which describes the magnitude of singular stresses ahead of a crack in a linear elastic body loaded in tension. For loading normal to the crack I.

l plane (Mode 1), fracture initiation occurs when the applied stress Intensity factor, K, equals or exceeds some critical value, which is l

t

2-4 i

L I

called the fracture toughness of the material. The applied stress intensity factor can be written in the form:

j I

Co/Ei (2.1)

K

=

I t.

where o is the acting stress, a is the characteristic flaw dimension, and C is a parameter which accounts for the flaw shape, structural geometry, and the type of loading.

In general, E is a f unction of a and in many cases must be evaluated numerically. Fracture will occur under quasi-static loading when, l

K 2 K (2.2 )

i i

i Ic t

(i.e., when the applied stress intensity factor equals or exceeds the static f racture toughness, K

).

This means that the occurrence of fracture is controlled by:

(1) the stress level, (2) the flaw size, and i

(3) the fracture toughness. For small flaws, low stresses and high toughness, the applied K will not reach K, and fracture will not occur.

These relationships are relevant for material properties determined under

(

ll plane strain, linear elastic conditions.

it T6 determine the significance of the inaccessible defects in question, ll Is necessary to know the material fracture toughness, acting stress level and actual distribution of defect sizes and shapes. Knowing any two of these parameters, one can solve for the third. For example, the critical i

flaw size to cause failure is calculated from:

Ic )2

{K I

r (2.3)

-2

/

a

=

WC k oc c

if both the toughness (K ) ar.d the stress level (o ) are known.

Ic c

Conversely, the critical applied stress as a f unction of crack depth can be computed from, f

a

't

4

2-5 K

l Ic g

o

=

C6a (2.4)

Although these conditions most appropriately describe the behavior of low toughness, h!gh strength materials where little ductility precedes fracture, the use of K as a toughness measure for either SA516 steel or ic E7018 weld metal ensures a conservative estimate of critical flaw size for 1

j brittle fracture, since no account is taken of the increased toughness j

which results from post-yleid (transitional) behavior.

Incorporating transitional behavior with more pre-fracture ductility gives increased I

' toughness levels and decreases the susceptibility of the structure to fracture from a given sized flaw. The temperature dependence of toughness properties means that at ambient or higher temperatures, both SA516 steel and E7018 weld metal are above their lower shelf values on a fracture 1

energy versus temperature curve. This in turn impiles that the use of standard elastic fracture mechanics will be conservative. Elastic-plastic crack opening displacement (COD) concepts have been used as a check on structural Integrity. Elastic-plastic fracture mechanics concepts are discussed in the next section.

ir 2.1.2 Elastic-Plastic Fracture Mechanics (EPFM)

The basic principles of EPFM have been developed over several years (2.1. 2-2. 2-1) and one national standard exists for crack opening displacement (COD) testing (2-1). This method uses critical 00D values (as e

measures of the material toughness) which are not available for the actual field material. A review of the literature (notably 2-fi) was made to check the appropriate material characteristics.

One of the best methodologies for EPFM evaluation, the British Standards Institution published document PD6493:1980 (2-1), utilizes crack opening displacement (00D) concepts.

In principle, the critical condition is reached when the applied K or COD (6) reaches the resistance level of

' toughness necessary to cause fracture (K or 6 ).

The COD method is I

completely compatible with the LEFM appr ch (2 R) and can be used in place P

,I.

.,-,.n

, - - _ -, - - -, - - - - -, - - - -. - - - -. - - - - - ~ - - -

2-6 f

I-of the K method. For applied stresses well below yield, Ic 8e a

(

)

~

Y F

(2.5) log sec I 6

=

f og-,

e where 6 is the developed COD; e and o are the yield strain and yleid stress of the region in which the defec is sited; o is the applled I

and a is the half crack length of a center-cracked plate model.

stress; l

It can be seen from Equation 2.5 that as o approaches o, the developed 5

COD becomes infinite. This only occurs for the elastic perfectly-plastic material behavior that was assumed for the development of Equation 2.5.

For materials that work harden, the relationship between 00D and applied strain (for stresses above yield) has been determined by analytical, numerical, anc experimental methods (2-L 2-1D).

As in LEFM, once the stresses and material properties have been characterized, it is possible to determine the allowable flaw size to prevent fracture Initiation.

It is then possible to determine the expected margin of saf ety between the flaws that may be in the structure and those necessary to cause failure.

2.1.3 Limit Load Analysis As the size of a critical flaw increases, a regime is entered in which increasing material toughness no longer can prevent initiation of a crack under monotonic loading. The initiation criterion becomes independent of toughness and now becomes a f unction of the strength properties of the material and the remaining ligament of material.

In this regime, a Ilmit load or plastic collapse analysis describes the governing f ailure mode.

For limit load analysis, the critical stress to cause failure is calculated

~ from an interaction relation common in the analysis of steel structures.

This relationship between the applled membrane load (P) and bending moment (M) at f ailure in a beam or plate with a rectangular cross-section is:

L:

2-7 i P )2 (M) 1 1

+1

=

(2.6)

(Pg

( Mj where P and M are the applied loads, and P and M are the limiting values of P and M.

The magnitude of P and M are functions of crack length a, flaw geometry and material properties.

l

- The limit load of P is determined from the geometry of the section and l

Af ter the reduction in area due to the flaw is the material properties.

accounted, the limit load can be expressed in terms of a limit stress and The limit stress is normally the material yleid the geometric variables.

'l strength when the material behavior Is assumed to be elastic-perfectly-plastic. However, for materials which exhibit l

significant strain hardening, o could be somewhere between yleid and 4

ultimate strength, and the appropriate value to use should be determined by i

tests.

For this analysis, we use a flow stress which is the average of the yleid li and ultimate strengths, i.e.:

(a

+o

)/2

( 2.7 )

I o

=

4 y

uts i

where o is the flow stress, o the specified minimum yleid stress and 4

y the specifled minimum ultimate strength.

a Once the limit conditions have been calculated, Equation 2.6 and the expressions for applied membrane stress as a function of pressure and applied moment can be used to deterniine the f ailure condition.

A limit load evaluation has been made in conjunction with LEFM methods in the present case.

2.1.4 Summary of Fracture Mechanics Background f

l The f ailure behavior of structures under monotonic loading can be t.-

L

s 2-8 classified into three regimes. Of these, linear elastic fracture mechanics has been determined to be most appiIcable to the current material and service conditions. Bounding studies based on elastic-plastic and plastic limit load analyses have also been performed.

2.2 Fn+Inug inading 2.2.1 Analysis Method In the The preceding discussion addressed the case of monotonic loading.

present case, there are a small number of cyci nc loads which may occur on l

- the containment structure. This section discusses the way in which these loads can be evaluated in the ilght of the previous discussion.

Fatigue evaluation, based on fracture mechanics, assumes that initial flaws are present of size a and that the lifetime of a component is that required for a crack to grow from the Initial size, a, to the critical 9

size, a. Crack growth rate data may be correlated to the crack tip c

stress Intensity factor range (AK) for the given load cycle in the following form:

f(AK)

(2.8) da/dN

=

where da/dN is the crack growth per lond cycle..By integrating Equation 2.8 with the appropriate component stress field to calculate K, the number of cycles, N, (residual life) for a crack to grow from a to a is I

c computed from:

(2.9)

N

=

da/dN da I

l The final flaw size expected at the end of the design life, a, can be f

determined by integrating Equation 2.8, using the appropriate stress distribution to calculate K, and the number of total design cycles N from o

f,

~

2-9

-a Sf da

=0 (2.10)

N da/dN O

I where Equation 2.10 is a transcendental expression involving a and must be solved by an iterative process.

~

2.2.2 - Crack Growth Rate Representation Many empirical relations to express da/dN behavior have been proposed; f

the earliest and most well known is the Paris rule (2-11) which takes the

form, C6K (2.11) da/dN

=

where C and n are constants determined from the data, and AK is the range of applied stress Intensity factor computed from the minimum and maximum stress in the cycle:

AK

- AK (2.12)

AK

=

max min The advantage of the Paris relation is that it is simple in form and it fits experimental data well In the middle range of AK. A disadvantage of the relationship is that it does not directly account for mean stress offacts (R-ratio offact where R = K

/K

) which can accelerate min max f atigue crack propagation. However, these of facts are accounted for in the choice of experimental data used in the modeling procedure.

j 4

2-10 i

e Section 2 REFERENCES 2-1 Wells, A. A.,

" Notched Bar Tests, Fracture Mechanics and Brittle Strengths of Welded Structures," Houdremont Lecture 1964, Bel +1 th Wal di ng Jnnrnal, No.1 (January 1965).

2-2 Sumpter, J.D.G. and C.E. Turner, " Fracture Analysis in Areas of High Nominal Strain," Prnemadinge Sannnd I n+arna+1onal cnnf erence on Prancura Vaccal Technoloay, San Antonio, TX (October 1973).

2-3 Egan, G.R., 'The Application of Fracture Toughness Data to the Assessment of Pressure Vesel Integrity," Prnenedinge Sannnd In+arna+1onal cnnf erence Qn Prancura Vaccal Technningy, San Antonio, TX (October 1973).

2-4 Burdekin, F.M. and M.G. Dawes, " Practical Use of Linear Elastic and General Yielding Fracture Mechanics With Particular Reference to Pressure Yessels," conf aranca on Penc+1 cal Annilen+ Ion ci Frac +ura Mechanics do Praccura Vacnol Dactgn, Institution of l

Mechanical Engineers, London, UK (1971).

l 1

2-5 British Standards institution, " Methods for Crack Opening Dis-placement (COD) Testing." (1972).

2-6

Stuber, A., J.Wellman and S. Rolfe, " Eighth Progress Report on Application of the 00D Test Method to the Fracture-Resistant Destgn of Pressure VesseIs," for_ Snhenmml++an on Ff f ac+1va 1.1+111rn+ Ion ci YIeI d S+rangth ni iha EY.BC.

(February 1980).

l 2-7 British Standards Institution, "Guldance nn Some Methods for I

2-11 t

-the Derivation of Acceptance Levels for Defects in Fusion Welded Joints," Published Document PD 6493:1980.

2-8 Egan, G.R., "Compatability of Linear Elastic (K ) and c

General Yielding (COD) Fracture Mechanics," Eng"naaring Frae+ura Machanics, Vol. 15, ( 1973).

2-9

Merkle, J., " Analytical Applications of the J integral," ASTM STP 536, Amartean Em-f a+v.far_ Tan +1ng and Material s, (1972).

2-10 Hayes, D.J. and Turner, C.E., "An Application of Finite Element Techniques to Post-Yleid Analysis of Proposed Standard Three-Point Bend Fracture Test Pieces," In+arna+1nnal Jnurnal at Fractura, Vol. 10 (1974).

2-11 Paris, P.C., M.P. Gomez and W.D. Anderson, "A Rational Analytic Theory of Fatigue," Iha Icand.l.D Fnginaaring, Vol. 13. No.

1 (January 1961).

l<

l l

I u

l l

--,, ~,..,,, - ~,,, ~ - - - -., - - - - - - - - - - -. -,.

F 3-1 Section 3 ANALYSIS OF STRESSES The analytical model discussed in Section 2 requires as input the characterization of the stress state present in the containment shelI This section discusses both the primary and secondary stresses.

courses.

The primary stresses are the applied stresses associated with dead load and cyclic service stresses. The secondary stresses, in this case, are the residual stresses due to welding.

3.1 saenndarv Stra==a=

The welds under consideration are double sided butt welds. A literature review was performed to characterize the resulting distribution of residual stresses in this type of weld. The weld has stress components transverse to the weld and longitudinal or parallel to the weld, each with through-thickness distributions. A schematic of these applicable distributicns is shown in Figure 3-1.

For this analysis the flaw location was assumed to be at the centerline of the plate which is the location for the maximum transverse stress. The flaw location was also assumed to be at the location of maximum longitudinal stress. The transverse distribution through-the-thickness wil I vary as shown in Figure 3-1.

Figure 3-2 shows single sided butt weld residual stress data transverse through the thickness. This figure is a composite of normalized experimental data based primarily on work done by Nordell and Hall 0.1).

In their work, the base plate was ASTM A212 Grade B (precursor to SA516 Grade 70)' with double-Y butt welds of E7018 material. The applicable thicknesses tested were 1 inch and 15/8 inches, requiring 12 and 30 weld passes, respectively. The two thicknesses demonstrated similar through thickness transverse stress distributions. Also shown in Figure 3-2 are residual stresses measured by others Q-2, 3-1).

e 3-2 h

Compression Tension I

\\

r i

Tension J

t""! "

j (a)

(b) i Compression Tension

/

L i

j (c)

Figure 3-1 Schematic Standard Assumed Residual Stress Distributions in Plates Without Fixed Ends for a Double-Sided Butt Weld:

(a) Longitudinal, (b) Transverse, and (c) Transverse Through Thickness.

(

~ ~ ~

~

Butt Weld (Single Side) Transverse Through Thickness 100 -

- 100 80 -

- 80

. 60 60.

/

g

'T 40

, gV

~~

y

[e 40 -

A

\\

/

- 20 D

20 -

/

'.m.

/

'A a

t

,nEn'

~

l

, w'

' ~

0 w

0 a

n 4v t, 20 y

e s

w 80

/

60 f

g l

t

.20 M I n,, '

/

i M

n S./

-40 o

~~

,/

e

'W'

- -60 E

-60i

-80

-80 Percent Wall Thickness

-100

-100 -

Nordell and Hall (3-1),15/8" Double V, Pies.e 1 (half shown)

~

Leggatt and Kamath (3-2),1" Double V, Un-notcht:3 (worst half shcwn)

Leggatt and Kamath (3-2), 1" Double V, Notched (wo m:. half shown)

A Nordell and Hall (3-1),1" Double V (half shown)

Y Nordell and Hall (3-1),15/8" Double V, Piece 2 (half shown)

  • Rosenthal and Norton.(3-3), 1" Sinale V l,

l Residual Stresses of Single Sided Butt Helds, Transverse Through Thickness Figure 3-2

?

J 3-4 n

From these ' data, a simplified through thickness transverse residual stress distrib'ution was developed. This is shown in Figure 3-3.

The distribution assumes yleid level r:esidual tenslie stresses at the surf ace through 10% of the ihickness. 'The tensile stresses then decrease to compressive residual stresses equal to one half yield at the mid-thickness. This distribution

. is then reflected about the centerline of the double sided butt weld to echieve a syrtmetric and complete distribution. Since any residual stress distribution must be self-equilibrating, the choice of values taken here

~~

wil'l be conservative. The sum of the tensile portions is larger than the

~

compressive portions and the maximum values have been assumed uniform

(

except in the through thickness direction.

l

.s t

I 3.2 PrImm-v Strancac l

lt ll The primary stresses for analysis have been obtained from unit stress l-calculations for joint 1 (CD-130) for welds 1-1 and 1-2; and from joint 5 l

~ (CD-139) fo-welds 1-4, 1-7, and 1-9.

The stresses in welds 1-7 and 1-9

( '

are substantially less than-in weld 1-4 (see CD-139 attachment 6).

A

{

bounding case has been formulated for welds 1-7 and 1-9 using the stresses in joint 5 (elevation 592'-2").

These stresses are summarized by joint number and Load Comt,ination for each Joint and the appIIcable load r

i-combinations.

Since the flaws found are oriented perallel to their welds, the stresses in the longitudinal direction apply. A schematic diagram of flaw orientation and applicable stress component is shown in Figure 3-4.

f The approach taken was to determine the most highly stressed joint and load

-combination for the appropriate sean welds.. These bounding cases could

?

then be applied to any weld defect, regardless of location, to assure a conservativo analysis, in f act, two prinary siress distributions were obtained for each weld orientation; one for the fatigue analysis and the other for the fracture analysis.

In order to understand how these stresses were determined It is necessary to review the tabular stress data as it was provided. Table 3-1 is the

Assumed Double Sided Butt Weld Transverse Through Thickness I

w 100 -

N

/-

100 i

~

n kl

\\

~

\\-

i.

/

i

,f,., j-g N

w 0 a 5 '*,Y,'~

l*

r

  • ~.

<.- k.'-

.% _ "l 0

Y,

~

a e.

o i

i

)

i 2

0.1

/

,/

/

' 0.9 N

5' -

g -

\\,,,'y,-

-- -50 y

g a

Percent Wall Thickness Figure 3-3 Assumed Double Sided Butt Weld Transverse Through Thickness Residual Stress Distribution

3-6 I-Vert cal Double Sided Dutt Feld 1

Longitudinal Stress or I

h v

%f

, Horizontal i

x Double Sided Butt Weld i

I I

  1. 9th N

9 Figure'3-4 Flaw Orientations and Applicable Service Stresses in Vertical and Horizontal Seam Welds i

(

l

I' 3-7 stress summary for Joint No. 5.

From this table one can see that the longitudinal and circisnferential stresses are broken down into thirteen load components and are then summarized at the bottom of the table into four load combinations.. These load combinations represent maximum loading conditions. Some of these load components act at alI times, some act The cyclically over the life of the plant, and some may act only once.

load components f allIng Into these three categories are summarized in Table 3-2.

For a f atigue anslysis the cyclle loads are of primary significance and are superimposed with the continuous or steady state loads.

For a fracture analysis the most significant loads are those producing the largest stress, which by observetion of Table 3-2, are those load combinations that include the single event loads.

Table 3-3 is a summary of the cyclic stresses that govern the fatigue i

- evaluation. There are other cyclic load components. However, the l

controlling load components in a given load combination are those listed in Table 3-3.

Thus, in order to simplify the analysis and provide i

conservative results, all critical load combinations were evaluated for

'i.

16,600 cycles, regardless of which cyclic load components the load combinations include. Table 3-4 shows the appropriate load combination components.

For weld seams 1-1 and 2-1, the stresses taken at joint 1-1 (elevation 575'-1") were used, as shown in Table 3-5.

For welds 1-4, 1-7, and 1-9, weld seam 5 stresses were used to bound the applied stress condition.

These primary stress fields were combined with the assumed reldual stress i

field for the analysis.

l 3.3 Combined Stranzas The total stress considered for the evaluation of a defect consists of the sum of the primary and secondary components. Both sets of stresses have been chosen to bound the expected stress state conservatively.

For analytical purposes, they have been superimposed with elastic m.

.,-,---s

.-.m.,___.-,.m,,,._._.,n_---n,,

e,_,,.

c

3-8 Table 3-1 Wm Panav Nuctue kwe RwT f_

M.,....d d

d W

O a--

a ----

g

.CALCULAT10si

...,** P Lut &nTE V C/1 >

2.,.e, s,,e i

t I

i Jowr' No.

'S EL59tM"CeaTA47 6 x..

g-a em s.., n; LON&lTl/OINAL= h (sWCUMK = Q I

_.. -LcAer Gasc -

Cuent Te< seer Ocre,se rus,oe l.

K II 4.__

_ _d35, _

'/.._lR

. */- 954.

IO R _

9.- l636.,.

___DE RI.0AD u... _.

g54.

19 %.

i UT N. MSE ElaTR00r4

__OEE. 5LO14

- 41..

.. 4 E...

..l4 I1.

2

- 15 4 162.

- 4 2.

So

QSE ' TILTED _Po?L.
  • isti)'z{in.st'cijZ[f, v 19ej g[f ec s sj.,qg_

1'L-p e W.E MT09tl URTmu.E h I' lod..

% 1 104.

% lE60.

% 1260.

SSE SLOSH

- Eg.

64.

- 18

'22

- 464.

4'75

- f 7 6. >

f 6Z.

Tit;r3.bE00.L S3Ei*'~4 b.c:

'meXiiso-' 5 szIgzJi or4.xiai[ rig,cq 66

- 67

- 4'6 6".

' * -- Gos.

  • r*ERNAL WDat061A1't LbAD Dwt 454.

7615. !

570.

1404..

sc.a w.usc x at e 5: 16 STric.INTIF'JALPHS%tE; eel)&MA%E._!UALYES_ X. 493.

  • /

.4.56,.

l*/- 211.

L 66.

W$KEEbE MVILYE l"PDP.N...,loq.

7,2.74.

  • /- 12 9.

'/-. 10.,,

i UD.5CWARGE l_VALyr Scsstoutr%, 361

+/- 469.

  • /- 2t4.

'/_. 33.

eta CCSSSAT104 05CILLAT10tl

+/- 1!!.

+/-

17.

  • /-

13.

+/ ',

S.

_.5ERC@G6]W,.,_.., _.$.41..

Y..,_43,.

'/, ] B..

. 7.

8.,,_,

-50STi,TC PRESSURE 16'I 76l.

Y"

~~~i[

~ ' 14[ " "

~

_LOCA POOLSwaL

- both Bis 4.

-in6.

..Mm.

-i'ais.

em.

- z2ies.

- is2ti.

osa toca wmut smss i5oC iiii.jmk' rcq! 7.nn? its /vu. '

  • =/ rii~[ ice nr.

f i

a %@ ~ '

i;,fo, 1s n.im? u4's. sisf.

(n (o, s a D @ @ @

,i

sV-1A a

._s) ni D:(D@G4:@i r. in,y*%htmengiic umi.p.

n.zi.j,v4.

'ce.

e' sn anahm a.. u2 A s

- n, s.

- c..../.u...

(

o...

.z.

l 4

f

.~

3-9 I

Table 3-2 CLASSIFICATION OF LOAD COMPONENTS BY FREQUENCY OF OCCURRENCF 1

Continuous or Steady State Loads Dead Load External Hydrostatic Load Due to Annulus Concrete Pour Rydrostatic Pressure 18'-6" Cyclic Loads DBE SSE SRV Discharge - 19 Valves SRV Discharge - One Valve,1st Pop i

SRV Discharge - One Valve, Subsequent Mean Condensation Oscillation Mean Chugging Single Load Events LOCA Pool Swell DBA LOCA Therwel Stress 15 psig Static Internal Pressure 1

l-f I

3 10 Table 3-3

SUMMARY

OF CYCLIC STRESSES TOTAL NUMBER NUMBER CYCLES OF CYCLES I

l.'

NUMBER OF PER OCCURRENCE OCCURRENCES 16,740 SOURCES 9

1860 50 SRV Actuation 10 S

10 OBE 10 l-1 16,800 SSE TOTAL J

l l

I i

c

3-11 4

Table 3-4 LOAD COMBINATIONS EVALUATED FOR ANALYSIS Load Combination Number Load Components I

DL + OBE + CONC + SRV) + HYDR 0 + PS II DL + SSE + CONC + SRV7 + HYDRO + PS l

III DL + OBE + CONC + SIP + SRVyg + CHUG + HYDRO I

DL + OBE + CONC + SIP + SRV2 + CHUG + HYDR 0 + LOCATH IV

(

Dead Load DL

=

Operating Basis Earthquake OBE

=

Safe Shutdown Earthquake SSE

=

External Hydrostatic Load Due to Annulus Concrete Pour CONC

=

15 psig Static Internal Pressure SIP

=

SRV Discharge - 19 Valves

~

SRV

=

yg SRV Discharge - One Valve, First Pop SRV

=

7 SRV Discharge - One Valve, Subsequent Pop SRV

=

2 Mean Chugging CHUG

=

Hydrostatic Pressure 18'-16" HYDRO

=

LOCA Pool Swell l-PS

=

LOCATHERM =

DBA LOCA Thermal Stresses I

~,y

3-12 Table 3-5 BOUNDING SERVICE STRESSES FOR JOINT 1-1 Stress (psi)

Outside Inside location Stress Component J.

Thermal 633

-5857

-818 421 Hydrostatic 2794 836 Design Pressure

-659 Dead Load

-492 PSRV 1085/-1847

-2078/3639 279 146 C0 SSE 1731 12194 4

OBE 1555 11664 l

\\.

Stress Range (psi)

Load Combination I

1569/-2473

-1891/498

-1361/-32

'II 1805/-2709 III 4509/175

-776/1055

-6633/-4802 IV 5142/808 (From CD-130)

Gilbert Ref. Letter PY-STR-1555 l

l t

3-13 i'l perf ectly-plastic material behavior.

The cyclic (primary or service) stresses are added to the residual stress distribution such that the maximum stress does not exceed the assumed yield stress of the material. The yield stress used for developing this distribution is 78.6 ksi (see Section 5).

1

, ~.. -

~,,,

c

3-14 Section 3 REFERENCES 3-1 Nordell, W.J. and W.J. Hall, "Two Stage Fracturing in Welded Mild Steel Plates," Wal ding Racanrch sunnf aman +, March 1965, Pp.124-S to 134-S.

3-2 Leggatt, R.H. and M.S. Kamath, " Residual Stresses in 25 mm Thick Weld metal 00D Specimens in the As-Welded and Locally Compressed States," The Welding institute, Report 145/1981, June 1981.

3-3 Rosenthal, D. and J.T. Norton, "A Method of Measuring Triaxial Residual Stresses in Plates," Welding Research Supplement, May 1945, Pp. 295-S to 307-S.

l l

['

l 1[

l 1

4-1 Section 4 FATIGUE CRACK GROWTH RATES In order to estimate the maximum extent of crack growth that could occur at an Indication over the design life of the plant, a f atigue evaluation was performed. This evaluation combined the cyclic stresses (Section 3) with the appropriate crack propagation rates (Section 4) to obtain the expected crack growth (Section 7).

The purpose of this section is to assess propagation rates for defect growth by a f atigue mechanism. With the exception of the possible plate defect In weld joint 1-4, the defects are located in weldments, thus requiring an evaluation of carbon steel weld material crack ' growth data.

References have been drawn together to estimate a conservative (that is fastest possible) bound on potential crack growth. Although no data are

~

available for the exact condition in ef fect, significant studies have been performed to permit bounding values to be estimated.

The foilowing engineering unit conventions are in of feet unless otherwise stated:

e AK (stress intensity factor range), ksi /IIi e T (temperature). 'F I^^

e da/dN (crack growth rate), Inches / cycle l

All weldnents evaluated are composed of E7018 weld metal. Data avaliable in the literature were collected for alI types of carbon steel weld metal L

with an emphasis on E7018. A study by Maddox (L1), resulted in a substantial amount of crack growth data for four dif ferent weld metals lr l

' ncluding E7018. The four types of test specimens from Maddox are r

i

4-2 sunmarized in Table 4-1 and the crack growth data for these specimens are plotted in Figure 4-1.

Crack growth data for The E7018 weld material (weld metal C) are shown separately in Figure 4-2.

Also shown on Figure 4-1 is j

the bounding line from similar testing on plain steels perf ormed by Gurney I

(.A=2).

Other data from similar weld metals (4:1) with and without stress relief, fall within the upper bound shown in Figure 4-1 for Gurney (3:2). The literature also states that weld metals for joining steels such as A516 Grade 70 exhibit slower f atigue growth rutes than the base metals (4-4).

Residual stresses may increase crack growth rate (da/dN), but if these stresses are included in estimating crack growth rates, the data indicate l

that the bounding line by Gurney (.1-2) will conservatively predict crack a

growth for E7018 weldments.

Figure 4-3 shows Gurney's upper bound which is represented by:

-10 3.44 2.63 x 10 AK (4.1) da/dN

=

The lamination-like defect in weld I-4 may propagate in either weld material or SA516 Gr. 70 base plate material depending on the exact defect location and orientation relative to the weld.

Both cases were analyzed to bound the possible ef fects. The growth rate used for SA516 Gr. 70 material was derived in previous work for Gilbert Associates (.d=1), based on bounding curves developed from work by Bamford (3 fi), and ASE Code Section XI L&=1). This work provides a three point curve depending on the relevant cyclic stress range.

-10 3.76 3.8 x 10 AK AK < 4.9 da/dN

=

-13 8.0 4.4 x 10 AK 11 >AK > 4.9 l

da/dN

=

1

-6 1.4 3.16 x 10 AK AK>11 da/dN

=

1 i

i

4-3 l

Table 4-1 TEST SPECIMENS FROM MADD0X*

-l I

YIELD ULTIMATE WELD AWS/ ASTM STRESS STRESS METAL CLASSIFICATION (ksi)

(ksi)

A None 74.4 88.0 A MIG deposit using CO2 gas shielding and 1 mm diameter wire Type A-17 to BS 2901, Part 2, 1960.

f B

E7013 68.3 73.9 A manual metal arc deposit of medium strength using a BS 1719 Class E317 rutile coated electrode.

C E7018.G 67.2 82.9 A manual arc deposit of medium strength using a BS 1719 Class E614 HJ low hydrogen electrode.

-D E9018.G 89.6 105.3 A manual metal arc deposit of high strength made using a BS 1719 Class E614 HJ low hydrogen electrode.

  • Ref.(4-1) l-i

{

i f

I

4-4 AK,kso Vih a

10 15 20 30 40

$0

  • 60 70 80 90 3

..ri.

l

,,fe s

ro <

/

, ',,(*,

y

[

.1 15 I

.Y* o **f

- ~~

e Scatter band for 4

+g 1

plain steels from o

gg.3 Gurney (4-2 f.,,* * *a *

/ ++ e a g+

a' 3

.._1._._

........ b

+f- e 7 2

.. _)U*

eg'f o a f- -4** *,.I I t 5 8 :- a 8 .'. 4 a g4 ,a4

e. a /

N %.;+. 6/ E l --

}'

E J s$ g, a a[ + A a ,c,- a,.- ,053 1 '. ej* a'0 .= 8 .+se g y 8 e ht5 + *s,M

  • 8 a

.,p e T 10 ' . + + ^^ ac i i ti I 8 2 ,V b 4 7 y ( g --- m y E o E s i f 'lf~ ~~ / a HAZ mild steel f l x weld metal B weld metal A e 3 e-fA of

  • l l

e weld metal C ,g.s + weld metal D l A

  • ;, l 2

/( /

  1. 5 e

a *a

  • as I

70-5 i i e i i f*10 15 20 30 40 50 00 70 80 90 100 S Range of stress intensity factor AK MNA 2 Figure 4-1 Crack Growth data from Maddox (4-1) t I


,-n

4-5 AK, ksiG. PC 624.6 10 15 20 30 40 50 x80 % 80 90 j i, i. i, 3 i n 10-4 / a 2 'l 15 ( s a -) 10'3 Y I n'. ) / 1 l /,'*

7 a

j 6 s n .) s'.i'/ h4 o es / AS 3 8 s o E i e s oY / k 3 l!',:,, 10-'R f yg sit .i 2 / 5 k / 8, [. / p E r a / } i '0"

/

.5 i u /

  • /I b

.f ffI o >l l / f/ / 3./ f ^ lI 4 = l 4 I 15.7 ksi t y I a 17.9 ksi f 3 f 20.2 ksi g-6 ,e / h13) x 31.4 ksi @appliedstress(ksi) ~ 2 5. i i yp5 9 10 15 20 30 40 50 00 70 80 90 100 Range of stress intensity factor AK,MNm*#2 l Figure 4-2 Crack growth data for E7018 from Maddox (4-1) 4

i 4-6 Stress intensity factor range, AK (MN/m /2) 3 l 4 6 10 20 40 60 80 100 10-3 ,,l 10 Bounding curve for SA516 Grade 70 N s i' 10-4 5 ~ b 5 3 y e 13 " 5 ~ E co u u C ~ l C E E k 10'b S ~ ~ c> 2 79-5 5 7 y e 3 m b

z..

a u 2 3n-6 Upper bound E7018 u Gurney (4-2) 10-6 I I 10-7 iiil i i i I iit i e 4 6 8 10 20 40 60 80 100 Stress intensity factor range, t.K (ksi /iii) Figure 4-3 Bounding Crack Growth Lines for E7018 weld metal and SA516 Grade 70 base material r k e

4-7 These values are shown in Figure 4-3. It should be noted that this curve is very conservative relative to alI experimental data reviewed and wil1 provide even more conservative results than the weld metal curve also shown in Figure 4-3. I( 8

4-8 Section 4 REFERENCES 4-1 Maddox, S.J., " Fatigue Crack Propagation in Weld Metal and Heat Af fected Zone Material," The Welding Institute, Report No. E/29/69, Abington, Great Britain,1%9. 4-2 Gurney, T.R. and S.J. Maddox. "A Reanalysis of Fatigue Data for Welded Joints in Steel," The Welding Institute, Walding Racanrch International, Vol. 3, No. 4,1973. I 4-3 Seeley, R.R., L. Katz and J.R.M. Smith, " Fatigue Crack Growth in Low Alloy Steel Submerged Arc Welds," Fatione Icsilog ci, WaIdments, Pp. 261-284. 4-4 Gurney, T.R., "An Investigation of the Rate of Propagation of Fatigue Cracks in a range of Steels," The Welding Institute Members' Report No. E18/12/68. 4-5 Egan, G.R., et. al., "The Significance of Sensitized Stainless Steel Material in Dryweli Vent and Containment Structures in the Perry Nuclear Power Plant - Fracture and Fatigue Evaluations," AES Report 81-11-88, November, 1981. 4-6 Bamford, W.H., "AppIIcation of Corrosion Fatigue Crack Growth Rate Data to Integrity Analysis of Nuclear Reactor Yessels," American Snefatv af. Machanical Fnnt naars, Paper No. 79-PVP-116, 1979. American Society of Mechanical Engineers, Boller and Pressure 4-7 Yessel Code, Section XI. i

5-1 ~j i Section 5 FRACTURE TOUGHNESS AND STRENGTH 5.1 In+rna uc+ 1 on ( l Two odditional model inputs to be discussed are the material propertles; fracture toughness and strength. As discussed in Section 2, the appiled stress Intensity is compared to a critical value which is defined as the fracture toughness. Thus, to determine allowable flaw sizes, the fracture I toughness must be characterized. Although no direct measurements of I fracture toughness were performed in the course of this work, inference about the level of fracture resistance inherent in the material can be made -l by reference to the Charpy impact values which are available. The background is presented in Section 5.2. The data are discussed in Section 5.3 for the containment welds and base plates (for possible plate delsmination of weld 1-4). Section 5.4 analyzes typical crack opening displacement values to be used in the elastic-plastic f racture mechanics eval uation. Section 5.5 addresses the yield and ultimate strength values to be used in the limit load assessment. Certified Material Test Reports I (CMTR's) (CD-4. CD-7, and CD-127) were analyzed to determine Charpy (CVN), yield strength and tensile strength data. Controlled document 127 was provided specifically to confirm the CMTR's for E7018 used in Weld Joint 1-1 between seams 21-22 where the largest defects occurred. C0-4 and CD-7 were obtained in previous work for Gilbert and list data for many heats of l E7018 used in containment welds. These data have also been included (see Table 5-1) to indicate the variation in material properties. 5.2 Frac +n

  • Tnnnhnace, Bacirnennnd To use the analyses described in Section 2.0, it is necessary to have the appropriate value of material fracture toughness in terms of the critical

'l plane strain stress Intensity factor (K ). Because of the excellent toughness in this material, these data are not normally available for weld j metals such as E7018 at temperatures around 70*F. Valid K data for Ic i 1 - + -,., r-

5-2 Table 5-1

SUMMARY

OF WELD PROPERTIES BY HEAT (AS-WELDED) WELD WIRE YIELD STRENGTH LIMIT STRESS AVERAGE TEMP. QC# CMTR# (KSI) (KSI) CVN (FT/LBS) (*F) 77NNI518 456 66.3 72.3 77.3 -30 77NNI540 472 78.1 83.2 69.8 -30 77NNI563 493 63.4 70.3 45.0 -30 78NNI004 552 68.8 75.7 82.6 -20 78NNIO13 557 65.8 72.0 95.2 -20 78NNIO14 557 68.4 74.3 109.6 -20 )- 78NNIO15 557 65.3 69.9 24.0 -20 78NNI016 557 65.5 71.4 85.0 -20 78NNIO24 625 65.3 69.9 24.0 -20

  • 18NNIl00 596 78.1 80.7 62.0

-20 78NNI163 630 68.2 73.1 76.0 -20 78NNI164 630 63.8 69.0 115.3 -20 78NNI202 646 66.9 71.5 120.2 -20 78NNI221 653 68.1 73.9 86.8 -40

  • 78NNI224 655 66.3 72.6 101.0

-20 78NNI255 663 70.2 73.6 118.4 -20 79NNI016 694 84.9 89.8 66.7 -20 79NNIO17 694 78.6 83.3 92.7 -20 79NNIO18 694 67.2 72.7 114.0 -20 l' 79NNIO99 710 64.5 71.3 84.6 -20 79NNIl00 710 70.9 76.4 102.4 -20 [ 79NNI131 716 72.7 79.2 80.3 -20 79NNI161 729 65.3 71.5 56.8 -20 L, 79NNI172 737 65.3 71.5 56.8 -20 80NNIO17 746 74.8 79.5 81.0 -20 80NNIO50 752 70.0 77.0 69.0 -20

  • 76NNI182 224 68.9 74.9 42.3

-30

  • 76NNI218 256 68.5 74.3 85.7

-30 l

  • 77NNIO58 398 70.0 73.8 138.0

-30

  • 77NNI519 69.0 73.8 113.3

-30

  • 77NNI589 520 69.7 73.7 109.7

-30 Taken from CD-4 and CD-7

  • Included in CD-127

5-3 l 1.5" thick material are generally only available at temperatures such as -100*F. However, it is possible to Infer Information about the relative toughness of the present material from available CMTR's. There are several correlations that have been proposed to relate Charpy energy to KIc values. These include two empirical relationships proposed and verifled by Barsom and Rolfe (1-1). The relationship for the transition temperature regime is: 2 (CVN) /2 3 2 K = Ic ( 5.1 ) E s i where Plane strain fracture toughness (psi /Iii) K = Ic Young's modulus (psi) E = Charpy V-notch energy (ft-lbs) CVN = s The corresponding relationship for the upper shel f regime is: fKl f ) a = 1 CVN - o a 20 (5.2) l y y where Material yield strength (ksi) o = Plane strain fracture toughness (ksi /lii) K = Ic Barsom and Rol fe found that at 80'F. the upper shelf correlation was appropriate for all material they tested. All their tests were with material of yield strength greater than 100 ksi, although they claim that Equation 5.2 is valid for materials with yield strength less than 100 ksi if dynamic yield strength is used instead of static yield strength. l 4 Another common correlation, due to Sailors and Corten, which was developed for A5338 and A517F (1-2), is t

5-4 O.5 15.5 (CVN) (5.3) K = Ic where ksi /In K = ft-lb CVN = Pisarski (1-3.) who reviewed and verified by experiment ten correlations i including those listed above, found that good predictions can be obtained for high strength steels (o > 113 ksi). For lower strength steels, the t y l correlations tend to be generally conservative with the degree of conservatism increasing with derreasing yield strength. Thus, eliher f Equation 5.1 or 5.3 should provide conservative estimates of critical fracture toughness. As a check, relations between critical crack opening I displacement value and K are also available from Rolfe and Barsom (5-4) Ic and Egan (ll-1). and take the form: 2 6 [KIc)i c _i (5.4) 'y Yy/ where Critical crack opening displacement (In.) 6 = c Yield strain (In/In) = o /E = cy y Critical fracture toughness (ksi /In) K = IC l Yield Strength (ksi) l o = y A f urther evaluation of typical crack opening displacement (COD) values is found in Section 5.4. e lf 5.3 Tnunhnamn Val nac IQr_ rnntai nment Wel ds Specific certified material test reports (CMTR's) were reviewed only for weld 1-1 between vertical joints 21-22 (CD-127). Furthermore. CMTR's for l Perry containment stif fener welds f abricated using E7018 were evaluated in 'l lI earlier work by APTECH (1-fi). These weld data are considered [ iI': l' 1

5-5 representative of those that would be found elsewhere in the containment. There is a large scatter of Charpy V-notch (CVN) data as shown in Table 5-1. The range of test values represented there is 24.0 to 138.0 f t-Ibs. The values given for CVH in the table are the " average." This is the average the 5 data points lIsted in the CMTR or 3 data points if 3 data points are given. In order to be conservative, the lowest CVN value was used to determine fracture toughness (K ) of the weld material. Thus, the 24 f t-Ibs. corresponds to a Barsom kolfe toughness value of 82.6 ksi /Tii. With the exception of this one heat, all other heats have calculated f K values greater than 132.3 kst /M. 1 Ic I These values represent tough welds, particularly since the CVN tests were I performed at a maximum temperature of -20*F. welI below the operating temperature. This fracture toughness value of 82.6 ksi/T6 will be conservative since: o The Barscen-Rol fe correlation used to arrive at these values has been shown to be conservative for materials with these j strength levels. ,e e Most calculated K values using this correlation are substantially abod$ this level. e The test temperature used to evaluate K is -20*F, whereas a higher temperature during opefEtion wilI result in correspondingly higher toughness. l l A lower bound determination of SA516 Gr. 70 toughness expected in the containment structure was performed in previous work for Gilbert Associates l1 (1-2). This value was found to be 73.2 ksi /T5-The derivation of this result involves considerable conservatism. I I

5-6 Other values determined from Table 5-1 to complete the analysis are yield strength and limit stress. The yield stress is used in determination of residual stresses, as they are a function of yleid strength level. The higher the yleid strength of the material, the higher the residual stresses. Therefore, the upper bound yield strength is used to determine the maximum possible residual stresses present. The limit strength is used .j i in evaluating the limit load capacity of the structure. The limit strength (o ) is defined as (a +o )/2 (5.5) o = 4 y uts g where o is the yield strength and o is the ultimate strength. For y uts 'I conservatism in the limit load analysis, lower bound values for yield and ultimate strength are used in the determination of the 1Imit strength. For yleid stress, a value 78.6 ksi has been used and for limit stress, 66.0 ksi. (See Section 7.2) The conservatism is apparent in that the prescribed yield stress is 12 ksi greater than the limit stress used in the analysis. 5.4 cr ack onaninn DIcnlaramant (COD) Valuan Crack opening displacement testing is used as a direct measure of fracture resistance. Literature data are available to provide typical C0D values for E7018. These are presented in Appendix A. These data were used in two ways. First, as a check in the derivation of K and second, as direct Ic input to the EPFM analysis. .( A check on derivation of the K value used can be provided by Equation Ic i I 5.4. From the data in Appendix A, the lowest COD value data at 32'F is .023". For this value of COD, and for c = 0.2%, o = 63.4 ksi (the Y y lowest strength material given in Table 5-1), the resulting K value is le calculated as: i

5-7 6 IKIc .c. 1 'y Ny) 214.9 ksi /In K =

(

Ic 1 1 Thus, the value of 82.6 kst/TK taken in Section 5.3 corresponding to a CVN value = 24 f t-lbs., is very conservative. .( l; 9 l i i i f l r i l l ll. t i f. i

5-8 Section 5 REFERENCES 5-1 Barsom, J.M. and S.T. Rol fe, " Correlations Between K and Ic Charpy V-Notch Test Results in the Transition Temperature Range," ASTM STP 466, (1970), Pp. 281-302. 5-2 Sailors, R.H. and H.T. Corten, " Relationship Between Material Fracture Toughness Using Fracture Mechanics and Transition Temperature Tests," ASTM STP 514, (1973), Pp.164-191. 5-3 Pisarski, H.G., "A Review of Correlations Relating Charpy l ,".Aa Eelding inn +I+u+e Resentch Energy to K T Bulla+1n- (December 1978), Pp. 362-367. j l 5-4 Roife, S.T. and J.M. Barsom, Fracture and Fn+1 gun Cnntrol,In S+ructurene Annilen+ Inns ci Fracture Machanics, Prentice-Hall (1977). l' 5-5 Egan, G.R., " Compatibility of Linear Elastic (K ) and General Yielding (COD) Fracture Mechanics," EngInnering Frnc+ure Mach anics, (1973), Vol. 5, Pp. 167-185. I 5-6 Egan, G.R., W.P. McNaughton and J.D. Byron, "A Fracture Mechanics Analysls of Containment Stiffener F1ange Welds in the Perry Nuclear Plant," AFTECH Report, AES-82-01-92 (April 1982). 5-7 Egan, G.R., et. al., "The Signif icance of Sensitized Stainless Steel Material in Dryweli Vent and Containment Structures in the Perry Nuclear Power Plant - Fracture and Fatigue Evaluations," AES Report No. 81-11-88, November, 1981. f A

6-1 Section 6 i CHARACTERIZATION OF FLAWS I The final input required for the fracture mechanics evaluation is flew size. The applied stress Intensity factor calculated by linear elastic fracture mechanics methods and the not section stress of the limit load method will both require an accurate description of flav dimensions. This wilI include both depth and length Information. Length information is generally easier to obtain as the projection of length onto f!!m is obtained by standard radiographic methods. Depth date have been less easily obtained without resort to volumetric examination by ultrasonic techniques or destructive testing technioues. For structural integrity evaluations an assumption has been generally imposed that ::onfines the flaw depth to one weld pass in multipass welds for certain defect types. Th!n assumption wilI be conservative for porosity and slag inclusion defect types. However, in many Instances it may be overly conservative. Such an assumption confining the expected defect depth to one weld pass will not however guarantee conservatism for " linear" defects like cracks, lack of fusion and lack of penetration. To more fully characterize both types of defects in the weld joints of Interest, a radiographic enhancement technique has been used. This is discussed in Section 6.3 below. The enhancement procedure also allows accurate length sizing of defects. When combined with equations of Interaction (discussed below), this allows the analyst to determine if two sdjacent defects or a series of defects should be most accurately represented as single Imperfections or treated as continuous. The details of defect interaction are discussed In'Section 6.2. The following section discusses the effect on structural integrity of' the rounded defect types, particularly slag inclusions. 6.1 Iba Effac+ ci llag inclusions na s+ruc+ure Intenrtig Work by Harrison (6::1) has indicated that slag inclusions have little i of fact on the tensile strength of butt welds up to considerable percentages l

9 [ 6-2 4 of cro'ss-sectional area. In support, he shows results of work by Ishil (M) and by KIhara (ft-3). These results are shown in Figure 6-1. Harrison further points out that by their nature slag inclusions are unlikely to occupy a large proportion of the cross-sectional area of a given weld and the weld metal will usually overmatch the base metal in strength. The conclusion to be drawn trem these f actors is that the of fact of slag inclusions on static tensile strength in materials like E7018 is negilgible. Harrison confirms that size-for-size, slag inclusions wilI be less detrimentel than cracks because of their roundness and limitations on i ~ their through-thickness size. A simillac conclusion is reached considering low cycle fatigue. Work by 'Ishll and lida (fc.4) is shown in Figure 6-2 and indicates that slag inclusionshavelitt{eeffectonload-controlledlow-cyclefatigueandup to lives of about 10 cycles. The design can thus be based on the static tensile behavior. For the analysis of these inaccessible defects, the structure may be subjected to as many as 18,600 cycles. This is stilI considered low-cycle fatigue for the purposes of our analysis, and the offact of slag inclusions wilI be welI characterized by the static loading case, particularly in light of the relatively low magnitude of the cyclic stresses (relative to the f ully reversed limit level stresses used to l generate the S-N curves of Figure 6-2). Additional results given in l figures 6-3 though 6-5 Indicate the ef fects on fatigue strength for high i. cycle fatigue. The number of cycles required to enter a regime characterized by substantial ef fects on life is shown to be at least an l order of magnitude greater than the design life in the present case. l In summary, Harrison (fel) states that there seems to be suf ficient evidence to indicate that under load-controlled conditions, low-cycle fatigue Is not a problem which will be influenced by the presence of slag f inclusions. The' tensile strength, o, of a defective butt weld wilI be either e.

Y. I 6-3 t, x, .i_.- e g,. s e ~. m. ~ l f i $tCfter 2112 Fr:* (,* e C' S.90-f,, }2::; ol 6 -- ---:. - - ;;-- " g _,t ' uw... rewa, <::c; : :.. Figure 6-1 Effect'of Slag Inclusions'on Tensile Strength (taken from 6-1) / ~ .t $ t c-vy-1 ' Shf,

  • ~

1.X* =1 t ..v. 3 m- ~,N LA !m-1 E m. \\ 1 is-.m,% 1 33. x.. _. c .u-... x -- J. J t as .o y n' , u-c' e' -n i. Figure 6-2 Results of Load-Controlled Repeated Stress Fatigue Tests on Butt Welds Containing Slao Inclusions I. (taken from 6-1) ', 1 ') f 'I t l ,c l [ F aD

6-4 ~~ 800 '.,ese s swa ***

300, e..es e se
e. ; y

,p s..+~.. se .ac.

7. '
  • r'., ',..,, >

= n - =rl ~x 11 .,z e san g L 1407 . e: - i isoN lao 13 \\ E'I I f r5 ,o. \\ t' s* c',.y,,,,,,,, 1 Figure 6-3 Results of Tests on Low-Hydrogen Welds Containing i Slag Inclusions up to 5m Long (taken from 6-1) j I I I 7.: u, l 35 'N e 50 > 2s s.*: ~ b, N..< l'l1 ea 15-I h* D2'{: d'.. [ / i*h Q'

  1. ia., ' k,...,

.V 4 2 i rA' i9 } } ts3 l0 4 -.yg 1- %s t a oc 0:' 10 I' 4. -J. C' c' c' s0 feew en,s tv,.ee r Results of Tests on Low-Hydrogen Welds Containing Figure 6-4 Containing Slag Inclusions up to 25m Long (takenfromfi-1) t

6-5 .a w N t" w p" N'%... :-..t l .. ).. n.. ~2 , y'w' *. y*, lo ; j> s ,e s> Is 7.4 31 s c: c-c.a. a-c, es... s;- u Figure 6-5 Results of Tests on Low-Hydrogen Welds Containing Slag Inclusions up to Continuous Slag Lines (taken from 6-1) I i a.

6-6 o (1 - AA/A) u,w or ou.p whichever is least. Where: o = the tensile strength of the weld metal o = the tensilo strength of the parent material ~l AA/A = ratio of the loss of area due to porosity or slag inclusion to the total area The ef fect of porosity on structural Integrity is similiar to that for slag inclusions. Figure 6-6 shows the of feet on tensile strength of a weld as a function of volume of pores. This figure is from work by Harrison (4-1). Figure 6-7 shows the effect on fatigue Ilfe for porosity defects for the case of low cycle fatigue. The behavior is similiar to that for slag inclusions. Harrison concludes for porosity (.6_1) that, "There seems to be suf ficient evidence to Indicate that, under load controlled conditions, low cycle fatigue is not a problem which wilI be Influenced by practical porosity levels." Furthermore: "In view of the probable necessity to limit porosity to some percentage probably well below 10% because higher levels would obscure other defects, there is no need to give f urther consideration to the offect of porosity on static ductile strength. This is because weld metals normalIy overmatch parent material strength and even where this is not the case i the percentage reduction in strength due to porosity is equal l to the percentage by volume of porosity and at a maximum of 10% this would not in any normal circumstances be significant."

50 , Ref. 6-6 ' R'et 6-2 7006,, -m ---m k~~'- / 40 ,Ref.6-3 ~ 600 $hkh$f$?!$$$$$5,fffjf>A. Q'% '5% i

  • 50u G

a a. '-+~ snna,. . 30 c g l -'s. s p e n p re a w w g m<y S s 400 E 20 E 2 R 6-7 ~ n 300-e Re1. b-H y g E 'm $200-10 ~ 10 0-0 0 2 4 6 8 10 Volume of pores % Effect of Porosity on the Tensile Strength of Figure 6-6 Butt Welds (taken from 6-5) l

45 1

700 _ 49 s I 600 - . 35 0 ~ \\ Percentag6 30 *e Porosity - 25 S n Ql400. I by volume f - 20 er l 1% }300 l 3% - 15 E l i y h200 - 10 l -9 -6 -7 g5 go 102 103 104 105 10 6 10 10 Endurance, cycles Figure 6-7 Mean S-N Curves for Load Controlled Tests on Porous Welds from Ref. 6-9 (taken from 6-5) { i I l

6-8 6.2 Defect i n+ arac +t on and.tha Madal ing nf. Def ects in light of the discussion in the previous section it is clear that the rounded defects such as porosity and slag inclusions will have less detrimental ef fects on structural Integrity than linear type defects. However, for the purposes of this analysis-we will continue to model the rounded defects as a sharp crack-like defect of the same size. This assumption wilI lead to a very conservative assessment of the potential for f ailure as caused by these Imperf ection types. Thus both linear and rounded defects wilI be treated as 1Inear imperfections. t Fracture mechanics analyses Indicate that the of fect of a surf ace Imperfection on structural Integrity will be much more severe than that of 'i a buried imperfection. Since we presently have no information about the relative location of the observed Imperfections within the weld (In one or 'i two cases'some location data are available in the form of ultrasonic 'i inspection records, but generally speaking this additional Information is not available). the assumption has been made that the defect is surface-connected. This will give the most conservative result in the calculation of applied stress Intensity factors. The model that has been l i used incorporating these considerations is the surf ace connected elliptical flaw as shown in Figure 6-8.

l-The available Information which is contained in the radiographs of the l

welds of Interest has been assessed using a computer enhancement system. ( That procedure is discussed in the foiIowing section. However. as a prelude to that discussion some preliminary remarks should be made regarding the Interaction of adjacent defects. The British Published ' Document PD 6493:1980, "Guldance on Some Methods For the Derivation of Acceptance Levels For Defects in Fusion Welded Joints" (fe10) provides perhaps the most complete detailing of interactions between weld defects. i A sample of those interactions is shown in Figure 6-9. Of particular interest are the criteria for Interaction for the coplanar surface defects ( and the coplanar embedded def ects. As can be seen, if the separation distance, s, was greater than or equal to the mean of the defect lengths l l i. I

6-9 1 } IFl

  • 305 - ILLIPTICAL $URFACE CRACK WP!t CEMtf TR)

L n v' J,(n..) L I I l l lf I 2 g ' "I Ii a r g g) m 3 ll l} l 1 y e y' iv W, "c PODEL DESCRIPTION i0 DEL FEATunt$ PARNIETER OPTIOI FCATURED Hodel Inden Nue.ber IF! 335 fiumber of Degrees of Freedom IDOF 3 Semi Elliptical Crack Front Shape Mode i Crack Opening Itode Finite Width Effects w No Variable Thickness Effects NTH No l' Figure 6-8 Schematic of Surface Elliptical Flaw Model

6-10 Schematic defects Criterion for interaction Effective dimenssons af ter interection 1 Consener surfece defects i \\ t=t2 1+12 1 i ,4 2 I = ls + 1 + s 2 f


~~~~~

- rij A gh3 I. t, 1 I l _- s, s 2 Coplanar embedded defects C. 2 t=ti+f2+8 s<U t, i 2 ) . I' j__t Is t 3 Coplanar embedded defects } f=f2 j s<1+1 l l 1 2 i \\ r;, - e - - - - - '- - - - - - - - \\ 2 f a t, li !_ s I t, .'I l = !s + 1 + s \\ 2 l L. - -~~-- j { } 4 Coplanar surfece and embedded defects t=ti+t2+s r, I \\ j i s<S+f2 M ?*, I. I, { ) t [ Tls I. \\ I& h ','s L 't 5 Coplanar embed 6ed defects l I s, < +2I2 t = ts + t2 + s2 E i I I s fGkD~ sna t, a s, e

  • '2

,-l s2 < g l=1+1+ss 1

2 6 Coplaner surface end embedded defects 2 t = tg + t2+s2 C'2 gg I \\ 7-i i--- snd s .s, 82 < ft +,2 2 I = l + 1 + st i 2 l@ /' ) i i,;,, l_ i, l., i, I Figure 6-9 Planar Defect Interactions (takenfrom6-10) i

6-11 t} } then the defects can be treated as separable for the structural integrity analysis. Furthermore, for def ects which Interact, the maximum defect depth has been taken to be the maximum of the two Individual defect depths as Indicated in Figure 6-9. 6.3 Digf +al Enhancament Methods lland in lha Procant Analvais Digital enhancement methods have been used in this analysis to provide accurate length and depth values to be used in the fracture mechanics calculations. The image of a radiograph is digitized and then computer i j manipulated to provide accurate measures of film density. Indications on the radiograph can then be Interrogated to determine their extent in the g l through-thickness direction. By comparing numerical measurements of density of Indications with known density changes from image quality indicator wires (penetrameters) or the plate thickness, the depth of l. Indications can be determined. In this case, the density at the defect locations has been compared with the general density of the surrounding

weld area to determine the through thickness extent of the defects in terms of a percentage of the weld thickness. A further use of the technique, particularly important in this case, was the use of digital Information to determine the extent of weld defects. This was performed by determining the " ends" of any given defect, that is the point at which the density was found to be Indistinquishable from that of the weld remote from the defect.

Once this location was found then the Interaction criteria given in the l previous section could be applied 1ro determine the defect length to be used fI in the fracture mechanics analysis. i The digital enhancement techniques used have been applled to several nuclear applications including both the enhancement of radiographic records and the real time signal enhancement of inspections by remote video camera. Appendix B provides futher Information about the previous uses of these techniques and includes a recent paper presented at the International -f Conference on Fracture Toughness Testing - Methods interpretation and Application in London, June 9-10,1982 (fell). which gives f urther 1 L

6-12 background information about the methods used to establish the depth of Indications in radiographs. 6.4 Fanuits of tha Elm Characterfration A total of 21 radiographs from weld 1-1, an 43 radiographs from weld 2-1, as well as film for weld 1-4 (79-80) 11-12, were examined using the j enhancement techniques discussed above. The results are given in Appendix C, which lists all the welds examined and the maximum defect length and depth found on that radiograph. In many cases, the maximum depth and length were on separate flaws. For example the maximum depth defect was usually a rounded Indication, but the longest defect was linear. It should be noted that the resulting bounding or worst case flaws will be much more accurately sized than simply assuming a depth equal to a full weld pass. Furthermore, the linear Indications tended to be shallow, although in some cases, relatively long. In most of the radiographs, the defects were singular or, by analysis using the interaction equations not separable. However, several of the longer defects were separable using the information provided by the digital techniques. l l The enhancement work allowed the following wcest case defect types, lengths l and depths to be entered into the fracture mechanics analysis: 1 l Weld Location Maximum Length Depth Weld ID l l Weld 1-1, 2-1 inaccessible Defects 4.0" 12.0% 1-1(21-22), 5-6 f 1.125" 14.35 2-1(35-19), 14-15 R1 (slag defect) i .g,-- .4-y. m..e,

9 6-13 Additional inaccessible Welds - Wold 1-4, 2.75" 10.0% Estimate of worst condition from CD-139, attachments 3-5 Welds 1-7, 1-9 1.75" 10.0% Estimate of worst condition from CD-139, attachments 3-5 4 1 e a

6-14 Section 6 REFERENCES ] 1 6-1 Harrison, J.D., " Basis for a Proposed Acceptance Standard for Weld Defects. Part 2: Slag inclusions," The Welding Institute,1972, Abington, Cambridge. 6-2 Ishil. Y., H. Kihara and Y. 'ada, "On the Relation Between the Non-Destructive Testing Information of Steel Welds and Their Mechanical Strength." Journal of Non-Destructive Testing i (Japan), Vol.16, No. 8,1%7, Pp. 319-345. IlW Document XI I l-466-67. 6-3 Kihara, H., Y. Tada, M. Watanabe, and Y. Ishil, "Non-Destructive j Testing of Welds and Their Strength," 60th Anniversary Series. i The Society of Naval Architects of Japan, Vol. 7. i 6-4 IshiI, Y. and K. IIda, " Low and Intermediate Cycle Fatigue l Strength of Butt Welds Containing Defects," Journal of the i Society of Non-Destructive Testing (Japan), Vol.18, No.10, 1%9, IIW Document XI l-560-69. i 6-5 Harrison, J.D., "The Basis for a Proposed Acceptance Standard l 8 for Weld Defects. Part 1: Porosity," The Welding Institute Report 26/3/71, March 1971, Abington, Cambridge. 6-6 Norrish, J. and D.C. Moore, " Porosity in Arc Welds and its Ef fact on Mechanical Properties," Second Conference on the Significance of Defects in Welds, London, May 1%8 (Published by the Welding institute). '6-7 Green, W.L., M.F. Harmed. and R.B. McCauley, "The Effacts of Porosity on Mild Steel Welds," Weld J. Res. Supp. Vol. 23, l

6-15 No. 5, Pp. 206s-209s. 6-8 Masi, O. and A. Erra, "L'Esame Radiograf ico delle Saldatura, Una Completa Valutazione del Dif feti in Termine di Resistenza Statica ed. a Fatica," La Metalurgica Ital f ana, Vol. 45. No. 8, 1953, P. 273-283. 6-9 Ishi, Y. and K. Ilda, " Low and Intermediate Cycle Fatigue l Strength of Butt Welds Containing Defects," Journal of the Society of Non-Destructive Testing (Japan), Vol.18, No.10, 1969. IIW Document XIII-560-69. 6-10 British Standards Institution, Guidance on Some Methods for i the Derivation of Acceptance Levels for Defects in Fusion Weided Joints," PD6493:1980, British Standard Institution. 6-11 Egan, G.R. M.F. Elgart and A. A. Smith, " Improved Radiographic Flaw Sizing by Digital image Processing," International Conference on Fracture Toughness Testing - Methods, inter-pretation and Application, June 9-10, 1982. r l:

7-1 Section 7 RESULTS OF THE ANALYSIS The following sections present the results of the analysis which were perf ormed using the methodologies discussed in Section 2.0 and the inputs of Sections 3.0-6.0. The results of the linear elastic fracture mechanics analysis are discussed in Section 7.1, followed by the results of the elastic-plastic and limit load analysis in Sections 7.2 and 7.3 respectively. FIact!e Frne+ure Mac_hanIen (IEFM) AnnivsIs 7.1 Recults af.dha }. IAC The LEFM analysis was periormed using the BIGIF (Boundary Integral Generated Influence Function) computer program. This program performs the numerical integration of equation 2.10. The program can be used to evaluate the ef fect of both cyclic and steady state loading on a structure. l 7.1.1 Indications in Seams 1-1 and 2-1 Table 7.1 summarizes the input conditions and results for the four bounding cases which were established. For seems 1-1 and 2-1, the maximum length defect could be modeled as 4.0" long and 12% of the weld thickness in depth (see Section 6.4 for details). The worst cyclic stress condition was found (see Section 3.3) to be load combination 111 (CD-130). These l conditions and the bounding f atigue growth rate developed in Section 4.0 were combined in case number 1, which is BIGIF run 1H1. The results are shown in Table 7-1. These Indicated that very small growth over the full l design life of the plant for these conditions can be expected. The possibility for fracture, given a maximum one time stress loading of this final flaw size was then assessed. The results are listed in Table 7-1 under case 1, run 1H2. The appropriate bounding stress case was load combination IV (CD-130). The results indicate an applied stress intensity factor (K ) for this bounding case to be 60.0 ksi In. This compares to a the critical value 82.6 ksi in (see Section 5.3). This in turn implies f that this size defect will not propagate by a fracture mechanism. i l' f

b / Table 7-1 SUt#4ARY OF RESULTS K Weld Data Stresses Bounding Flaw Evaluation a 7 pg, Case No. Orientation Seam No. Joint Load Combination Lenath Depth For! ksi/In. KICK + 60.0 1.37 l 1 1H1 Horizontal 1-1, 2-1 1 III-+3 4.0 12%(.180) Fatigue 1H2 Horizontal 1-1, 2-1 1 IV- $ 4.0 '12%(.180) Fracture 60.0 1.37 3 1H5 Horizontal 1-1, 2 1 III-4 1.1 14%(.214) Fatigue-57.5 1.44 3 l 1H6 Horizontal 1-1, 2-1 1 IV- $ 1.1 14%(.214) Fracture 57.4 1.44 3 2 6H1 Horizontal 1-4 5 III-4"'3 2.75 10%(.150) Fatigue 54.68 1.345 6H2 Horizontal 1-4 5 IV- $ '9 2.75 10%(.150) Fracture 54.68 1.345 4 3 6H3 Horizontal 1-4 5 III-4"'9 2.75 10%(.150) Fatigue 54.68 1.51 I 6H4 Horizontal 1-4 5 IV-4"'9 2.75 10%(.150) Fracture 54.68 1.51 4 8H1 Horizontal 1-7, 1-9 5 III-$" 1.75 10%(.150) Fatigue 53.48 1.54 y 8H2 Horizontal 1-7, 1-9 5 IV-4" 1.75 10%(.150) Fracture 53.48 1.54 N l NOTES: 1. Fracture and fatigue susceptibility checked for worst load combination 2. Maximum at end of design life 3. Taken from CD-130 \\ I 4. Taken from CD-139 4 l 5. Check using base plate growth rates and toughness 6. Check using weld metal growth rate and toughness properties 7. K taken to be 82.6 ksi/T5 for weld metal, 73.2 ksi/in for base metal Ic 8. Governing case is load combination III 9. Note true applicable stresses will be in "z" direction and thus substantially lower than longitudinal stresses used as bound

7-3 A deeper defect was found during the enhancement work. This led to the development of additional computer runs 1H5 and 1H6 using a bounding defect 1.125" long and.214" deep. The resulting value for K was less than a that for the longer flaw (57.5 ks! In versus 60.0 ksi in). 7.1.2 WeId 1-4 t The plate Imperfection of. weld 1-4 was modeled using stresses from weld Joint 5 (CD-139). Since the location of the Imperfection could be af facted by either weldment or base plate properties, both possibilites were run. Case 2, runs 6H1 and 6H2, use base plate properties. It should be noted I that the actual orientation of the defect is such that stresses to af fact it would be the through-thickness stresses which are very smalI (CD-139). For purposes of this bounding analysis the flaw has been modeled as if I oriented normal to the maximum stresses in the longitudinal defect. The i results wilI thus be very conservative when obtained. As with the Imperfections in seams 1-1 and 2-1, the combination of stresses and flaw . size modeled predicts structural failure wilI not occur for either set of material properties. 7.1.3 Welds 1-7 and 1-9 It was noted that weld 1-7 is at worst a 9/16" long slag line. In weld 1-9, an excavation for repair was made and that area is not covered by RT to assure repair was completed. Attachment 3 in CD-139 reasons that a bounding case of a flaw 13/4" long will bound both 1-7 and 1-9 defects. Case 4 runs 8H1 and 8H2 have been established to evaluate this bounding flaw taken to have a depth equal to.150". The stresses of Joint 5 have l been used in this evaluation although the true stresses in the upper parts of the containment near joints 1-7 and 1-9 are substantially lower (compare CD-139 attachments 2 and 6). Even with the conservative bounds, this model predicts structural failure wilI not occur. i t 7.2 Limit Load Analvnft As discussed in Section 2.0, limit load provides a bounding method of a

7-4 analysis for structural failure. It is based on two theorems. The first gives rise to lower bound solutions and states that a structure wilI not fall if the applled forces can be balanced by a redistribution of stress such that the Induced stresses do not exceed the yield or flow stress. The l second theorem, which is an upper bound theorem, states that the structure wilI collapse when the rate of external work done by the applled forces exceeds the rate of internal plastic work for any collapse mechanism. As the first theorem provides lower bound results, it will be used in this ( analysis. Many solutions have been developed to calculate the critical stress for various geonetries and loading conditions using the lower bound theorem. Several of these are reported in (1-1.). For a center-cracked plate under uniform tension (Figure 7-la): o = o (1-2a/t) (7.1) c 4 and for a single edge-cracked plate in tension (Figure 7.Ib): (7.2a) 'j "c

  • O (1-a/t)[ 1+1n 1-a/2th] for a/t 5 0.884 t

1-a/t / and

  1. c = 2.571og (1-a/t) for a/t > 0.884 (7.2b) i l

These solutions are for infinitely long flaws, which provide overly conservative solutions. The ef fect of flaw aspect ratio may be considered by replacing a with: t I 2 2 a(1-(1+1/2t)-i) 2 2 (7.3) 'i 1-a(1+t /2t )-1/t I For the present case, o has been taken to be: l

= t = __= t = n-_- __ 2 a * .,_ a. ? m ^

a. Center-cracked Plate
b. Single Edge-cracked Plate Figure 7-1 Flaw Geometries for Limit Load Analysis

7-6 o = 1/2(o +c) (7.4) 4 y u Where o and o are the minimum values of yield strength and tensile y u r strength. The minimum limit stress in E7018 can be taken to be 66 ksi which corresponds to the specified minimum tensile and yield strengths of 72 ksi and 60 ksi respectively (taken from AWS A5.1-78 " Specification for ,'l Carbon Steel Covered Arc Welding Electrodes" (1-2). Simplification to the governing equations occurs in this case because any bending stresses applied to the structure will appear as a uniform stress i across the section. Further, the size of the detail is suf ficiently small so that a crack wilI not af fect the Integrity of the structure by net loss of sectional area. Limit load wilI thus indicate f ailure when the applled stress in the net ligament is equivalent to the maximum stress which the section will support, or the limit stress. The critical area loss to cause l. limit load failure was determined from the maximum appIIed tensile stress. The maximum design tensile stress is found to be in Joint 3, load combination IV, longitudinal stress component o, inside surf ace and is equal to 33,136 psi (CD-139). P If i This worst case stress will only result with a section ligament loss of 49.8%. Since the maximum depth defect is 14.3% the ratio of worst defect depth to critical depth is 3.5. Thus, there is a large margin against failure by a limit load mechanism. 7.3 EIactIc-PIactIe Frac +ure MachanIen (FPFM) RacuIts To assure that the linear elastic fracture mechanics analysis was conservative, an EPFM analysis was completed utilizing the concepts outlined in Section 2.1.2. The basis for this analysis is the "Draf t l British Standard of the Rules for the Derivation of Acceptance Levels for Def ects in Fusion Welded Joints" (h3.). Since a rigorous elastic-plastic analysis is very complex compared to LEFM, the Draf t Standard has t I

7-7 simplified the procedure by using a semi-empirical design curve set in its current form by Burdekin and Dawes (1-4). Experimental work was performed by Burdekin and Stone CZ-1). For a defect in a uniform stress field, the relationships befween (X)D and applied strain are: $ = (e/e )2, for 0 < e/e < 0.5, c y y (7.5) <2 $ = e/e, - 0.25, for 0.5 < e/ey where $ Is the non-dimensional (X)D, i.e., i $= 6 (7.6) 2ne _a y 1 The 000 design curve, shown in Figure 7-2, relates the non-dimensional CDD, _$, to the ratio of applied strain to yield strain. The appiled strain is taken as the local strain which would exist in the vicinity of the crack if the crack itself were not present. It has been shown (1-6) that this design curve is conservative, and thus the allowable flew size, a, will be a smaller than the critical flaw size, a The design curve is based on a through-thickness defect (a = through-thickness crack hal f-length). Although not rigorously justified, it has been suggested that the of fact of crack shape is the same for contained yielding problems as for IInear elastic problems (1-1). Thus, a pseudo-elastic-plastic solution to part-through cracks can be developed. j For a through flaw with the geanetry shown in Figure 7-3a, the LEFM expression is: I (7.7) For a surf ace crack with the goemetry shown in Figure 7-3b, the LEFM lll'

Nea ) 6 7 fe s 3 R mo r f ( e v r u C ng ise D w 0 r 0 u y C c 2 n e g le 2 rs e D 7 0 e 0 r C ug i F 1 3 2 i1l i l1 I!,l l ll

?o t = r w wa 1 l wh F a de t i a r r 2 u B h a ) c c 2 = e yr te e m w oe a G l F t e ce c f a t f e D = r h u S 3 7 ) c a e b ru g c i U b 2 F ~ m=. wa l a F m2 h g E uo W)h r T a i 1!: ,;a' !4

1lI:^

9 7-10 expression is: YS cAia K = g (7.8) $2 r where M is the magnification factor due to finite thickness of fects. T 2 s the elliptic M is the free surf ace magnification factor, and $ 1 integral of the second kind. It can be seen that i 3 K(Ithrough-thickness flaw j (7.9) i K = surface flaw $2 From this relationship, solving for an equivalent through-thickness crack size gives: [M M 1 yS I"Y I( #2) (7.10) a a i ~ 1. l. The val ues of -- S= f ere taken from a survey by Maddox (1-A), and are shown in figure 7-4. It can be similarly shown that for a buried elliptical crack with the geometry shown in Figure 7-3c: fM M) 2 g i "7 (7.11) where M is the magnification f actor at a point due to the nearest free e o I-surf ace and M,Is the magnification factor at that point due to the more remote free shrface. These values were derived from the finite element

7-11 so %.o l~ Et i l l s 40 ,[. 2 c~ M "I '4e.0t s a 20-

  • 4c.01

/ n.c > f.S_s sc- %e %,e = I l l 0 t 1 I t f I f 0 01 02 0-3 04 05 06 07 06 l Variationof(Mh/0)withCrackDepth Figure 7-4 3 l' for Various Shapes (from Ref. (7-7)) 1 . e.

7-12 1 work by Shah and Kobayashi (2-2), and M and Mnare shown in Figures 7-5 o and 7-6 respectively. The elliptic integral, 4 ' IS P otted in Figure 7-7. l 2 For a/c ^= 0; M M was derived from Fedderson's relationship (2-1.0): oW f 1/2 i sec, 3 l M= ( .tj l Thus, combining the (X)D design curve with equations 7.6, 7.10, and 7.11, a relationship can be developed between allowable flaw size and allowable strain levels for each crack conf Iguration. The Draf t Standard contains criteria which require that when a crack tip approaches a free surf ace, the flaw should be reassessed as a surf ace-connected flaw (a buried flaw is recategorized as a surface flaw and a surface flaw is recategorized as a through-thickness flaw). The buried flaws present can be conservatively f modeled as surf ace flaws and in the present case, only such surf ace flaws and through flaws have been considered. The critical value for crack opening displacement was taken to be 0.023" as outilnad in Section 5.4. The yield strain is assumed to be 0.2%. The b calculated allowable flaw sizes for surf ace defects are shown in Figure 7-8 for 1.5 inch thick weldments. The theoretical development.used is valid to strain ratios (e/e ) up to Y 2.5 but are plotted beyond that point to demonstrate that at flaw depths of i approximately 10% of the welI, a very large margin to fracture exists. The results are shown for a variety of aspect ratios. For a/2c = 0.0, an infinitely long flaw is modeled. The theory provides a recategorization process at a depth of 50% of the wall thickness. The flaw should then be considered as a through-flaw. Figure 7-9 shows the results of the elastic-plastic through-flaw analysis. The length of a critical flaw as a function of strain is given. For through-flaws, residual strains are not included. t

yLw 4 b 1 0 0 0 0 0 0 1 2 4 6

8. 0 c

l E a 0 0 O 0 01 C A F R U 8 S 0 E E R F T S E 6 R 0 A EN h / 5_ R / e 7 O er F ug 4 i R F O 0 T CA F N O I 2 T 0 A C I F I N G A M ~ _

  • O 0

8 6 4 2 0 ~ 2 1 1 1 1 1 MNM I

li 4 MAGNIFICATION' FACTOR FOR FARTHEST FREE SURFACE 4 i i i i i i i i i i i i i i i i i i i 1.20 n/c 0.10 - 1.15 f 0.20 _ y 1.10 y g s x 0.40 - 1.05 0.60 ~ ~ / 0.8 l 1.00 - 2-1.00 O 0.2 0.4 0.6 0.8 1 l c/h1 Figure 7-6

m..u-, r m 4 4_ 4 p g %M m pg 4 - t J T ELLIPTIC INTEGRAL OF THE SECOND KIND ~ i. i. i i i i 1.6 eum e m 6 l 1.5 But 6 6 6 6 1.4 w e 1.3 ~ ~ m ~ G e e 1.2 W 6 O 6 6 1.1 Gu'l 6 h 6 1.0 O 0.2 0.4 0.6 0.8 1 c/c Figure 7-7

r~n .~ ~ STR AIN vs. CRITICAL FLAW SIZE (SIJRFACE FLAW) i' i ii i i i i. i i 5'i.\\ ~ ,g a/2c-0.4 c ,l 6 -0.023 in. t-1.500 in. \\ 4 ~ a/2c-0.3 3 m 4-u. N a/2c-0.2 E e e 2 ~ n/2c-D.1 _; ~ ] 1 1 i a/2c-0.0 O '.7 5 O 0.25 0.5 0 1 1.25 1.5 i FLAW DEPTH, INrilFS Figure 7-8 Strain versus critical flaw size for.l.5" thick weldments l

STRAIN:vs THROUGH-THICKNESS CRITICAL FLAW SIZE i i, i 5 ~ s -o.023 in. o 4 3 ~ y e G s w 2 1 0 O 2 4 S S _0 FLAW LENGTH. INCHES i Figure 7-9 Strain versus through-thickness flaw (EPFM)

7-18 For the present case, the ratio of maximum applied strains to yleid strain is approximately 0.5 so that long through-flaws are predicted prior to fracture by EPFM methods. Most relevant cases have lower strains and correspondingly larger predicted altowable fIaw lengths. Two notes are of Interest here. First, the toughness used was taken from generic data and not plant specific Inf ormation. Thus the flaw values should only be used to gauge the reasonableness of the LEFM approach as was their intent. Second, this EPFM approach has an inherent minimum factor of safety of 2 on flaw size.(1-11) t 1 i 9 l l l i

7-19 Section 7 REFERENCES 7-1 Chel l, G.G., " Elastic-Pl astic Fracture Mechanics," central Electrieltv Racanrch Imhnratories, Report No. RD/L/R 200F, (August 1979). 7-2 American Welding Society, AWS A5.1-78, " Specification for Carbon Steel Covered Arc Welding Electrodes".1978 7-3 British Standards institution, "Draf t Standard Rules for the Deriv-atton of Acceptable Levels for Defects in Fusion Welded Joints", WEE /37, February,1976. 7-4 Burdekin, F.M. and Dawes, M.G. " Practical Use of Linear Elastic and Yielding Fracture Mechanics with Particular Reference to Pressure Yessel s". Instt +ution af. behanf ea t Fnginaars C5/71. 7-5 Burdekin, F.M. and Stone, D.E.W., "The Crack Opening Displacement Approach to Fracture Mechanics in Yleiding Materials". Journal of l Strain Analysis, Vol.1, No. 2, (1%6), p.194. t. 7-6 Harrison, J.D. et al, "The ODD Approach and its Application to Welded Structures". _The hiding instituta Racanrch Rannet I 55/1978/E, January (1978). 7-7 Dawes, M.G., " Fracture Control in High Yield Strength Weidments", l ( Welding Journal Research Supplement, Vol. 53, (1974), p. 369s. l 7-8 Maddox, S.J., "An Analysis of Fatigue Cracks in Fillet Walded Joi nts", In+arnational Jnurnal d Fracture behantes, Vol. 11, No. 2. April (1975) pp. 221-243. ,{ll l l L

7-20 7-9 Shah, R.C. and Kobayashi, A.S., " Stress Intensity Factors for an Elliptical Crack Approaching the Surf ace in a Semi-Infinite Solid", i n+ rnm +1 ona l.innenal af,renc+ure m ehantes, Vol. 9, No. 2, (1973) p.133. ~ 7-10 Fedderson, C.E., " Discussion to Plane Strain Fracture Toughness Testing". ASTM STP 410, (1%7), p. 77. 7-11 Kamath, M.S., "The (X)D Design Curve: An Assessment of Yalidity Using Wide Plate Tests". The Welding institute Report 71/1978/E, September, 1978. F 1 M 9 E

8-1 Section 8 CONCLUSION AND

SUMMARY

This report sunmarizes the results of an evaluation of the ef fect on structual Integrity of several weld Imperfections. These Imperfections were assessed from Indications in radiographs and have been analyzed in separate regions as follows: e inaccessible defects in weld seam 1-k and 1-2 I 1. e Potentially rejectable inaccessible regions in weld 1-4 e Potentially rejectable inaccessible regions in welds 1-7 and 1-9 It has been found that assumed bounding defects of each category will not cause structural f ailure over the plant design lifetime. This analysis has included the ef fects of: e Flaw growth by a f atigue mechanism e Residual stresses e Worst case applied stresses (steady state plus cyclic) l l f e Maximum defect sizes l [ Throughout the analyses, conservative estimates of input data have been ( used. These are summarized as foilows: e Methodologies. The LEFM method used has been shown to be ~ -, -

8-2 obnservative in this analysis as compared with both elastic-plastic f racture mechanism and limit load methods. The LEFM calculated final flaw conditions do not account for the Increased ductility that w!!! be available at operating temperatures. e Residual stresses. Bounding values from distributions published in the open literature for like weld details have been used. I L e Flaw location in the through-ihickness direction e Flaw geometries. In all cases semi-elliptic surf ace flaws have I been used to bound buried and near surf ace flaws. Many of the I flaws thus bounded may be buried, in which case, substantially larger margins against f ailure occur than those listed. l I e Crack growth rates. Upper bound crack growth rates for E7018 weld metal were developed and used to predict the enount of of crack growth. e Choice of applied stresses. Bounding stress cases (including numbers of cycles) have been used. e Material toughness. Material toughness values derived from 00D data were shown to be conservative. In addition, data was collected at -20*F. which is much lower than the expected service tanperature. I e Limit strength of the material. Values were estimated that result in conservative estimates of renalning ligament. l ,y w -~- w ww

A-1 !,j { l Appendix A j ( SUPPLEMENTAL TOUGHNESS DATA I I. e e l t l !'i I l

4 e APPENDIX A CRACK OPENING DISPLACEMENT (COD) VALUES - E7018 WELO METAL -TEST TEMPERATURE C00 DIAMETER REFERENCE (oF) (in.)- (inches) COM4ENTS I -20 .0182 5/32 Lincoln LH-70 Ductile Ductile -50 Ductile Ductile -100 .0107 I -20 .0133 5/32 Lincoln LH-72 k .0192 Ductile -50 .0018 .0113 -100 .0011 I +14 .0224 1/8, 5/32 Lincoln LH-72 .0118 .0209 2 10nn C0D specimens for E7018 weld metal II -76 Tearing -76 >.030 1 in2 C00 specimen. E7018 weld metal

APPEtiblX A (Continued) TEST TEMPERATURE C0D REFERENCE foF) Hn.) DIAMETER C0ft1EllTS -94 10 values ranging British equivalent to E7018 III' from.008.034 i = 20.00 s = 10.01 -40 22 values ranging British equivalent to E7018 III from.016.048 i = 34.45 i s = 9.246 32 22 values ranging British equivalent to E7018 III from.023.052 i x = 39.68 s = 7.305 1 =

A-4 J APPENDIX A REFERENCE LIST FOR FRACTURE TOUGHNESS DATA - E7018 f I. Personal correspondence between W. McNaughton (Aptech Engineering Services) and R.C.' Shutt (The Lincoln Electric Company), Dated l May 22, 1979. i II. Dawes, M.G., " Designing to Avoid Brittle Fracture in Weld Metal," Metal Construction and British Welding Journal (February 1970), Pp. 55-59. III. Tait, P. and D.M. Haddrill, " Fracture Toughness of Some Mild Steel Manual Metal-Arc Weld Deposits," Welding and Metal Fabrication (September 1970),Pp.370-375. j l 4 E

B-1 i l' Appendix B BACKGROUND INFORMATION ABOUT DIGITAL IMAGING TECHNIQUES I s ( l i 1 1 3 L

B-2 APTECH incel29 = = ' = = = " " " 795 SAN ANTONIO ROAD

  • PALO ALTU = CALIFORNIA 94303 (415) 858
  • 2866 INSPECTION SIGNAL ENHANCEMENT SERVICES FOR THE NUCLEAR POWER INDUSTRY Aptech Im.ging, Inc., has developed unique digital signal enhancement schemes which are applicable to a wide range of inspection signals. Three particular applications of this technology have been developed as follows:

Enhancement of existing inspection information, such as x-rays, radiographs, or videotapes. Real-time x-ray imaging systems or filmless radiography. f j Records management to store and retrieve in digital format, radiographs, engineering orawings, etc. These enhancement techniques have already had wide application in the nuclear We power industry to aid resolution and interpretation of inspection signals. have outlined below some relevant experience in the nuclear power industry. CLIENT SERVICES PROVIDED Southern California Edison Enhancement of indications in radio-San Onofre Generating Station Unit I graphs of welds in main steamlines r I Boston Edison Company Enhancement of images from underwater Pilgrim I television cameras of core spray sparger. This work was performed by enhancing existing video tape recorded in 1980. We performed on-site real-time enhancement in conjunction with the inspection at the 1981 outage. Gilbert Commonwealth Asspciates/ Enhancement and interpretation of Cleveland Illuminating Company radiographs of containment welds. Perry Nuclear Rolls Royce Nuclear Ltd Enhancement and interpretation of old radiographs. ,s Enhancement and restoration of out-of-General Electric Company specification radiographs for cast nuclear valve bodies. DigitalImaging Systems for inspection, Records Management and Signal Enhancement

2 Nuclear Regulatory Commission Enhancement of radiographs of stress corrosion cracks adjacent to welds in Type 304 stainless steel. Bechtel Power Corporation Demonstration of digital records management system to store and retrieve ~ radiographs'and engineering drawings. Battelle, North West Demonstration of enhancement techniques for underwater viewing of reactor l internals. (. Consolidated Edison Company Radiographic enhancement for defects and restoration of old radiographs. r i Enhancement and interpretation of defects i, General Electric Company in radiographs of nuclear plant valve bodies. Enhancement of video tape inspection GPU Huclear { records of core spray sparger. j Enhancement of video tape inspection records of cora spray riser piping and reducer. On-site real time enhancement of video I signals from core spray sparger and annulus inspection. Enhancement of radiographs of stress Northern States Power corrosion cracks in primary piping. f Power Authority, State of New York Enhancement of original fabrication radiographs from steam generator closure weld. Bechtel Power Corporation Determination of defect dimensions South Texas Project (length and depth) in emergency cooling water lines. Enhancement of radiographs from pipe to Duke Power Company valve welds. Enhancement of piping radiographs f rom North East Utilities fiillstone III. Further details about these services and individual utility contacts can be provided to you on request. l t

  • )**

actura Toughntss Tcsting - CONFERENCE As receiv d PAPER NO 28 blethods, Interoretation & Application late AUTHOR (S) G.R.Eran, bl.F.Elgart & A. A. Smith type script IMPROVED RADIOGRAPHIC FLAW SIZING BY DIGITAL IMAGE PROCESSING G. R. Egan,* M. F. Elgart,** and A. A. Smith"" 9 1.0 SYNOPSIS This paper describes the calibration and application of a digital image processing method to determine the depth of indications seen on radiographs. The image of the radiograph is digitized and then computer manipulated to provide accurate measures of film density. Indications on the radiograph can then be interrogated { to determine their e.: tent in the through thickness direction. By comparing numerical measurements of density of indications with known density changes from image quality indicator wires or the plate thickness, the depth of indications can be determined. i A calibration procedure is also ' described wherein known defects were introduced into a steel sample which was then radiographed. A comparison of the digital processing size estimates and the actual dimensions of the defects shows excellent correspondence. An example of the application of this technique to lack of root fusion defects is also described. i i i l lI t {

  • APTECH Engineering Services, Inc.
    • Aptech Imaging, Inc.

"* Consulting Engineer

I 2 l

2.0 INTRODUCTION

Fracture mechanics principles have been used to characterize a wide range of f failure mechanisms including brittle fracture, ductile fracture, fatigue, stress corrosion cracking, and also weld cracking phenomena. The analysis required to characterize any of these crack extension mechanisms is based on determining a l material property (e.g., toughness in the case of fracture problems), the acting stresses that can cause crack extension, and calculating the critical flaw size 4 for crack initiation or continued crack propagation. In any of the ar.alysis methods that have been developed there are uncertainties in the input data that l .are used. For example, in the very simple case of assessing the critical flaw tests, uncertainty in the size to cause brittle fracture, scatter in data of KIC f definition of stresses including residual stresses and the errors associated with flaw sizing techniques mean that when critical flaw sizes are calculated, margins j of safety must be established before the results can be applied. ) Since, in most cases, there are insufficient data to perform a full probabilistic analysis of the problem, it is necessary to choose bounding values of the input data to fracture mechanics equations so that the resulting calculated value of critical stress or critical flaw size is regarded as a conservative estimate. Pursuing this procedure to its logical conclusion often results in such pessimistic predictions that currently operating equipment is deemed to be in jeopardy from some predicted failure mechanism Q). It may well be the case that operating limits are so restricted that major economic penalties are incurred by performing so-called " conservative analyses." One answer to this dilemma is :.o l" perform the complete probabilistic analysis to establish the probability of failure by the mechanism that is described by the deterministic fracture mechanicsequations(2). Having derived this number, however, there is usually uncertainty in establishing the sign"ificance of such numbers (3) and comparisons of risk between different events can be made to judge the comparative significance of an outcome. By looking at uncertainty in the input parameters, it is possible to establish a For ranking of importance of input variables to any fracture mechanics analysis. example, by the very nature of the equations that describe the interrelated 1

3 i variables, we are able to establish a ranking in order of the importance of particular input parameters. With this ranking, we can then concentrate on refining methods for decreasing the uncertainty in any set of input data. The importance of establishing the initial flaw size can be determined by studying the equations which describe some of the fundamental failure mechanisms. Table 1 outlines the relationship between calculated critical flaw size and the measured flaw size for three different failure mechanisms--fracture, high cycle i fatigue, and stress corrosion cracking in sensitized Type 304 steel (4). It can I i be seen that the importance of flaw size dimensioning increases as the exponent I of K or AK in the equation that describes the failure phenomenon. This has also led to the establishment of the half life concept for both fatigue and stress corrosion cracking (5). In this paper, we concentrate on developing methods to improve sizing of defects { discovered by either x-ray or radiographic techniques. We anticipate that this work will lead to better and more reliable methods of flaw sizing. Although much research is currently being undertaken to improve the reliability of inspection systems, it is clear that a key element that contributes to the t i uncertainty is the presence of a human interpreting and recording information. The work that we describe following is aimed, in the long term, at providing automatic pattern recognition systems for flaw detection and sizing. f I 9 9 I ( v+y

4 Table 1 IMPORTANCE OF FLAW SIZE IN FRACTURE MECHANICS ANALYSIS FLAW SIZE FAILURE MECHANISM GOVERNING EQUATION DEPENDENCE I -b Brittle Fracture o = a c gg m - 0 1* 1 } 3 ( 1-l a Fatigue N = Y ') ( ,{ m-2 2 ,-3** i Stress Corrosion Cracking T o "ax a = m i of Sensitized 304 i t l

  • For m = 3 l
    • For m = 8 I

I I

l' 5 \\. 30 DIGITAL IMAGE PROCESSING TECHNIQUE _S

3.1 Background

The digital image processing techniques that we have developed are described in i detail elsewhere, however, a short sumary of the basic background technology will be provided here (6). A diagram of the equipment that is used to capture 6 images in digital format is shown in Fig.1. The image collection system (i.e., a television camera) can deal with signals from x-rays, radiographs, pictures, and printed pages. Once the information is digitized and stored in the computer, j manipulation by mathematical methods of analysis can be performed to provide images that can be interpreted by the non-expert. The APTECH system shown in Fig.1 outputs information to a television monitor from which hard copy can be obtained by normal photographic means. In addition, copy can be provided on either magnetic tape, video tape, or video disc. 3.2 Treatment of Radiographs The primary advantage of radiography as a nondestructive testing technique is I -l associated with the fact that an image is involved. The use of an image enables both expert and non-expert to interpret effectively the meaning of the test results.. However, because of his experience, the expert radiographer will l usually extract more information from an image than a non-expert will. The amount of discernible information is unfortunately biologically limited. Although film contains sufficient information to detect density differences of 0.05% to 0.1%, the human eye can only resolve grey levels which differ by at least 1.5%. Therefore, the film has captured much more information than the eye I can extract. Additionally, the eye discerns a boundary or edge condition only when two adjoining areas of an image differ by more than 15% in density. The full range of film density information can be made available to the observer by use of digital techniques of analysis. Small density differences not discernible to the unaided eye can be made visible on a television monitor by expanding a small density range on film to the full white to black grey level information. Then ^

. = - - - i 1 i 1 2 A-D CONVERTER <w w TV f ) CAMERA MONITOR OBJECT l I I 1 J L i a i l CAMERA 4 l CONTROL e O TAPE I l Disc I o I D STORAGE l l CAMERA SOFTWARE COMPUTER j / 4 Figure 1 - Aptech Imaging System. i

7 since the image is in discrete digital form, mathematical methods can be directly applied to provide image enhancement. Images are currently captured using a 512 x 512 matrix, and each pixel in this matrix contains grey-level information. Grey level information or radiographic density is provided on a scale from 0 to approximately 4000. 3.3 Procedures for Depth Heasurement of Indications Since the computer can discern density differences from white to black, on a grey level scale of 0 to 4000, the sensitivity on depth measurement in a full grey . scale is 1/4000 of the depth of the piece being examined. Furthermore, for defects that lie normal to the plane of the radiograph, it is possible to establish a density or defect size profile using information derived from image quality indicators or the plate thickness. For example, since the computer L provides such a sensitive measure of density, it is possible to calibrate a radiograph by using density changes associated with image quality indicators. Details of this procedure are outlined later.

(

ll In addition, for dimensional verification, for establishing the dimensions of radiographic indications in the plane of the radiograph, it is possible to I perform automatic integration schemes that will yield defect length and width. The sensitivity of these measurements is 1/512 of the extent of the image being processed. Since mathematical magnification models are available, it is possible to develop the required sensitivity in the length and width directions. An example of dimensional verification by computer is shown in Fig. 2. The foregoing description leads to the natural conclusion that we are able to plot out in three dimensions, defect profiles. From a single radiograph, it is possible to do this; however, one important piece of information is missing and l -that is the location of the indication within the thickness of the part being examined. The procedure has certain limitations related to the eccentricity of buried defects, however, for surface connected defects, the procedure can be used in a straight forward manner. Some coments are made later on how the procedure may be changed to establish positional information relative to the two free s'urfaces of the parts being examined. l am --,.-.>.---w.-- .-.4

t 8 l 4 a t,., < [p s, ^ ' .I t 1, 9,(. - . J 9p mir ,. s 3, s,:...l = ' ist \\ 3.j, 3 '/ . - x - . g,. i ~ - ,7 s. S. ,,f s.s+ t - 2.. l .} i !,1 .. [ u ly / j c. ( i, [ l 2a. Digital Information Plotted to Define Edge. i i r r.. ,w., .

  • c. ;,

.,e. ... ~s :. l .%s 3..,- j .y. 8 .;y T >,.m.:

,,, 4 e L..;

r.). yi 3 y, w .. ~ .s'c..- j 3-q ' . %c g m ; :;...~7},7 3 (, y ' i -l(, .l 44.f.. /,. ' J, 4 t ;,.+. 4 - .r.<4., .;-,e < . a v ..t. q. . +..: -. *A.. ~,o

x wg y -

[ l. Ls'. ..;a...g 3;r ~ :r -%y,,.. '....i .. p,, .. *... :, '..y n. .'i... o. + 's, i n.,.......,c-.) 5. ^ g, 5 .,. ~,.. . q Z,y x 1. .r..s 1 3 ...,y t, m, .m...,,., '. I . ;Q y% '(...a ,s.: % y 1 t 2b. Dimensioning by Computer. Figure 2 - Example of Dimensioning by Computer. l


'wei--=wm.-ww

-.iw-w-v =-w '.*v m'N'- 1 " ' ' ~ '

l 1 9 / 3.4 C411bracion To determine that the procedure does provide accur' ate measures of defect depth into a plate from a single radiograph, we have performed a calibration procedure using blocks containing defects of known dimensions. Details of the calibration blocks are shown in Fig. 3. For convenience, we shot the calibration blocks in real time and captured the information on videotape which was subsequently digitized and processed. The image could also have been collected on film. On:e the image had been collected on videotape, the information was presented to the computer in digital format. We were then able to establish measures of defect height through the thickness for the range of defects contained in the blocks l (Fig.4). The defects consisted of machined notches and drilled holes, and these were also measured using gauge blocks. A comparison of the two methods of measurement is shown in Table 2. It can be seen that a small uncertainty still exists in the dimensioning of defects by this method, but it is significant improvement on existing methods of determining size information by nondestructive means. 1 l l l 1 l

l 10 1 '{ t [ '\\,,, - i y )! ; i u v i-t l l ,..[___,',_^ . 4' r s Figure 3 - Calibratior. Blocks. t I I , 97 '

  1. ~ ":<.,,,_

y' ' D-(.. G, Q e I ..:Q "i... C ', 4 s .K- ..... a..? :A L' L Figure 4 - Photograph of TV Monitor Displayed Image of Real Time X-Ray of Block IV. + -,.--.--.-,.---e., y-.-----,-...-w..w,,,----..-w--.v-..

11 i Table 2 RESULTS OF CALIBRATION - BLOCK 4 (. i Digital Information Estimated Depth Measured Depth } ' Defect Full Plate Defect (inch) (inch) l L h 451 2550 3390 0.107 0.110 2775 J h 452 2775 3380 0.800 0.075 2900 4S3 2900 3370 0.068 0.060 2925 l 4H1 2200 3260 0.162 0.113 6 o 2200 2200 ti[ 2200 g 4H2 2350 3050 0.125 0.098 2350 2250 2200 2335 4H3 2400 2870 0.086 0.067 2400 l' 2350 i -__,,,e y-_-rm- --.,,--r-

12 4.0 APPLICATIONS In this Section, we outline a specific application of this technique to indications derived from radiographs of offshore platform welds. In each case, we have determined a calibration coefficient from the image quality indicator and the part thickness and used this to establish the through thickness extent of indications in the radiograph. These dimensions can then be compared with fracture mechanics calculations to support continued operation of these o it structures. u t 4.1 Offshore Pipeline Welds In this particular example, we were supplied with radiographs of welds from the main legs of fixed platforms located in relatively shallow water (i.e., less than 100 feet). The radiographs were generally of poor quality and out of focus because of the large object to film distance. We processed the radiographs by applying an artificial focus procedure which essentially consists of squeezing the d digital information down until the picture becomes focused. The results of this procedure are shown in Fig. 5. After tnis procedure was completed, we then l interrogated the image quality indicator wires to establish a unique calibration for each radiograph. Having done this, we then established the depth of indications that were apparent in the root of the welds. These were surface connected defects so that the calibration procedure was straight forward, and the c missing information for through thickness position was not necessary. An example h-of the procedure used is shown in Fig. 6. i. From Fig. 6, it can be seen that not only can depth information be established, but the procedure also provides information about the type of indication (i.e., rounded or linear). The techniqu'e has also been used for defect identification. h I

,1

l

'13 i )

  • * (;.rv. 2S

+.A & Qt.s Y N *,, M v - u.. ~: / lf t ) i

l c

Figure 5 - Root Pass of Weld in Offshore Platform. i l< l 1 i l _ ee s22 l f,.T..E... . ~. s3 _i.jgy:1Q I .W 2. - - ~ ( 2 I i Figure 6 - Example of Digital Screening for Defect Depth and Dimensions. "f""- WP=ewWve"*'w---g>y-p*we+g9yywe p9--__ sy_ ,_,_m

t' a 14 I 5.0 CONCLUDING REMARKS It would be unrealistic to conclude without a few cautionary comments. First, the f technique that we have developed can only be used on images that have not been enhanced using non-linear transforms. Obviously, in such enhancements, where particular parts of the grey scale are compressed, a calibration on one part of I the' radiograph would not apply at other locations on the radiograph. Second, where the indications are smallsr than one pixel (1/512 of the image), unique depth informction cannot be determined. This is not really a practical limitation i. I because it is possible to capture a smaller part of the radiograph. I In additio'n, from a single radiograph we cannot determine the location of the indication'in the through thickness direction. It is necessary to take one other shot at an angle to be able to reconstruct all of the positional 1nformation. Even in spite of these limitations, we have found that for surface connected defects there is a need for an accurate method of estimating depth of indications. The work is continuing with the objective of developing an automated process for providing defect dimensions and positions. llr i 4 u

,A

/.

/ 15 ~'9 . REFERENCES j 1 Snaider, R. P., J. M. Hodge, H. A. Levin, and J. J. Zudans, " Potential for /. Low Fracture Toeghness and Lamellar Tearing on PWR Steam Generator and ' Reactor Coolant Pump Supports. Pesolution of Technical Activity A-12," NUREG- ~ '0577 for Coment, Office of Nuclear Reactor Regulation, U.S. Nuclear ..s ? " Regulatory Connission (October 1979). 2 Thomas, J. M. and D. C. Peters, "Probabilistic Decision Model for Structures Subjected to Crack Growth and Fracture," ASME Winter Annual Meeting, San i Francisco (1978). 3. C. Starr, " Benefit-Cost Studies in Socio-Technical Systems," Colloquium on Benefit-Risk Relationships for Decision Making, Washington, D.C. (April 1971). 4. Egan, G. R. and R. C. Cipolla, " Stress Corrosion Crack Growth and Fracture Predictions for BWR Piping," ASME, New York (1978). 5. Hayes, D. J., " Fracture Mechanics Based Fatigue Assessment of Tubular Joints. Review of Potential Applications," AES 81-01-45, Shell Oil Company (January 1981). 6 Elgart,.M. F. and R. H. Richman, "Real Time Digital Techniques for - Radiography," Proceedings of Workshop on Nondestructive Evaluation of Turbines and Generators, EPRI WS 80-133 (July 1981). i y $[ i. F. i i. .( L a

i l C-1 i Appendix C DETAILS OF THE FLAW CHARACTERIZATION WORK O e

C-2 b L

SUMMARY

OF RADIOGRAPHS REVIEWED INACCESSIBLE WELDS JOINT STATION DEFECT LENGTH (Max) DEPTH (Max) I 0.75" 5.8% l Unit 1 1-l'(21-22) 4-5 Elongsted Slag 4.0" 11.0% 1-1 (21-22)- 5-6' LOF 1.0" 11.4% 1-1 (21-22) 11-12 LOF 0.3" 10.7% 1-1 (21-22) 12-13 LCF 0.5" 6.0% 1-1 (24-25) 9-10 Elongated Slag 0.63" 13.3% 1-1 (24-25) 16-17 LOF 0.4" 11.1% 1-1 (25-26) 10-11 LOF 0.75"

12. %

1-1 (26-27) 9-10 LOF 0.2" 8.8% 1-1 (27-28) 4-5 LOF 3.9% 0.6" 1-1 (28-29) 3-4 LOF 4.5" 8.8% 1-1 (28-29) 4-5 Slag 8.7% 0.32" 1-1 (28-29) 5-6 Elongated Slag 13.6% 0.5" 1 1-1 (28-29) 18-19 LOF 12.5% 0.5" 1-1 (29-30) X-17 LOF 0.75" 5.4% 1-1 (30-31) 8-9 Elongated Slag 1.25" 10.0% 1-1 (31-32) 11-12 Elongated Slag 1.0" 11.3% 1-1 (32-33) 2-X Elongated Slag 1-1 (33-34) 24-25 No Defects Observed 0.5" 8.8% 1-1 (34-35) 17-18 Crack / Pore 0.5" 1.7% 1-1 (35-19) 1-2 LOF 0.19" 5.3% 1-1 (35-19) 6-7 Isolated Slag 4.5% 0.7" 1-4 (79-80) 11-12 Slag Unit 2 l 2-1 (19-20) 1-2 Slag /LOF 1.0" shallow 2-1 (19-20) 3-4 Pore /LOF 0.62" 9.0% 2-1 (19-20) 4-5 Slag / Pore /LOF 0.25" 5.0% 2-1 (19-20) 12-13 Slag 0.75" shallow 2-1 (19-20) 15-16"R1 Slag / Pore 0.4" shallow 2-1 (19-20) 17-18 R1 Slag /LOF 0. 4" shallow 2-1(19-20) 18-19 Slag /LOF 0.75" 4.0%

.) C-3 JOINT STATION DEFECT LENGTH (Max) DEPTH (Max) 2-1 (20-21) 10-11 Slag 0.5" shallow 2-1 (20-21) 11-12 Slag /LOF 0.62" 6.2% 2-1 (20-21) 12-13 LOF 0.5" shallow 2-l'(20-21) 14-15 Slag /LOF 0.4" very shallow 2-1(21-22) 4-5 Slag 0.5" shallow 2-1 (21-22) 5-6 Slag /LOF 0.5" 7.4% 2-1 (22-23) 11-12 LOF 0.4" shallow 2-1 (24-25) 7-8 Slag /LOF 0.5" 5.3% 2-1 (27-28) 0-1 R3 LOF 0.31" shallow 2-1 (27-28) 1-2 Slag /LOF 0.62" shallow I 2-1 (27-28) 11-12 Slag /LOF 0.4" rounded } 2-1 (27-28) 13-14 LOF 0.5" 3.0% 2.-1 (27-28) 16-17 LOF 0.6" shallow 2-1 (27-28) 19-20 Slag / Pore 0.4" rounded 2-1(28-29) 12-13 Slag 0.75" shallow 2-1(28-29) 13-14 Slag 0.5" shallow 2-1(28-29) 24-25 Slag 0.62" 6.0% 2-1(28-29) 25-0 Slag / Pore 0.62" 7.6% 2-1 (30-31) 0-x Slag 0.5" shallow 2-1(30-31) 6-7 Slag /LOF 0. 4 '- shallow 2-1(30-31) 11-12 Slag 0.19" very shallow 2-1 (30-31) 12-13 Slag /LOF 0.5" 7.3% 2-1(30-31) 13-14 Slag /LOF 0.5" very shallow 2-1 (32-33) 8.9 Slag 0.25" very shallow 2-1(32-33) 10-11 R2 Slag 0.4" very shallow 2-1(32-33) 11-12 Slag /LOF 0.4" 8.0% 2-1(32-33) 16-17 Slag 0.4" 10.0% 2-1(32-33) 19-20 Slag /LOF 0.5" 7.7% 2-1(32-33) 23-24 Pore /LOF 0.5", 0.06" 5.7%, 9.0% 2-1 (33-34) 7-8 R1 Slag /LOF 0.5" 12.5% 2-1 (35-19) 0-1 Slag 0.19" shallow 2-1(35-19) 1-2 Slag /LOF 0.19" 7.1% 2-1(35-19) 10-11 Slag /LOF 0.25" 3.8% 2-1(35-39) 14-15 R1 Undercut / Slag 1.125" 14.3% 2-1 (35-39) 15-16 Slag 0.5" 10.7% 2-1(35-39) 20-0 LOF 0.5" 7.7% - - ~. ~ ye-,,

DI .1 1. Appendix D CONTROLLED DOCUMENTS i f i 0 l I l l I l L_

D-2 APTECH ENGINEERING SERVICES DOCUMENT LOG CONTROLLED DOCUMENT NUMBER ITEM 4-(AES-8110276) Volume 1 of 1 Containment Horizontal Stiffener Ring Flanges for rings 1-4 including CMTR's. 7 (AES-8110276) Volume 1 of I Containment 1 Horizontal Stiffener Ring Flanges for rings 5 and 6, including CMTR's. 125 Letter PY-CEI/GAI-5519 dated 11-15-82 from W.T. Melia to R. Alley. 126 NNIC letter dated October 26, 1982 to R.W. Alley from B.R. Cofer on subject of Perry Nuclear Dower plant Contain-ment vessel analysis of weld 1-1. 127 Certified material test reports of weld 1-1 between vertical welds 21-22. 128 R. Dail preliminary report to R.W. Alley dated November 16, 1982 on limited re-view of containment vessel radiographs. 129 Longitudinal stresses weld 1-1 showing Rev. O thermal, hydrostatic, design pressure, dead load, SRV, OBE and SSE stresses. 130 Letter PY-STR-1555 information, dated November 29, 1982, from R.W. Alley to W. McNaughton, including Rev.1 of stresses included in CD-129. 131 Letter dated 11-5-81 from B.R. Cofer, NNIC to R.W. Alley, GAI on subject of containment Vessel Analysis of Weld 1-1 Indication 132 NNIC letter dated 9-24-82 on prelimi-nrry summary containment vessel embedment raalysis - Figures 1 and 3. i 133 UT reports - inaccessible shell joints. 134 Letter to J. Keppler from D. Davidson dated 9-30-82. 135 Letter to R. Dail from W. McNaughton results of enhancement of radiographs 1-50 A/B (1-2), 1-1 (17-18), 1-1 (24-25). 136 Letter to W. McNaughton from R.W. Alley transmitting radiographs 1-1(24-25),9-10 and 1-2 (45-46), 14-15. L

D-3 CONTROLLED DOCUMENT NUMBER ITEM 137 Letter report dated December 7,1983, W.. McNaughton to P. Gudikunst preliminary results of inaccessible defect evaluation, -weld 1-1. 138 BIGIF com5 uter runs 139 . Letter from R.W. Alley to W. McNaughton PY-STR-1587, February 16, 1983 : Memo R. Dail to R. Alley Unit I containment radio-graphs : Stresses in Joints 2-6. : Memorandum E.M. Horeth to B.R. Cofer, December '7, 1982 : Memorandum B.R. Cofer to M. Lastovka December 17, 1982 : Memorandum R.L. Dail to R. Alley January 4, 1983 " Review of NNIC Evaluations of Indications in Contain-ment vessel circumferential welds 1-4. : Letter B.R. Cofer to R.W. Alley, February 3,1983 " Data for Analysis of Welds 1-7 and 1-9. ~140 Receipt of Design Materials letter from W. McNaughton to P. Gudikunst, Decemb'er 20, 1982. 141 Letter from W. McNaughton to K. Nebb (site) returning radiographs dated 3-11-83. l l 142 Acknowledgement of receipt of radiographs listed in CD-141 (from K. Webb) I 143-Letter from K. Webb (site) sending (29) radiographs with acknowledgement 3-23-83. l 144 Letter from K. Webb (site) sending (15) radiographs with acknowledgement 3-24-83. 145 Letter from R. Alley to W. McNaughton summarizing radiographs sent and stresses which correspond. PY-STR-1607 3-31-83. I

D-4 i CONTROLLED i DOCUMENT NUMBER ITEM 146 Letter from K. Webb (site) to W. McNaughton sending 6 radiographs 4-4-83. 147 Letter from W. McNaughton to R. Alley April 19, 1983 "Aptech Evaluation of 4 shell courses defects - background information". 148 Summary of radiographs reviewed cons-isting of notes and measurements. e 149 Documentation of locations on each radio-graph of CD-148 as to depth measurement location. E' l 150 Videotape with balance of Gilbert enhancement. 151 Stress calculations - load combinations as taken from CD-139 and checked. 152 Developed integrated stresses - service and residual stresses. 153 Limit load analysis. 154 BIGIF runs used in final report - 1H1, 1H2, 1H5, 1H6, 6H1, 6H2, 6H3, 6H4, 8H1, 8H2 i I .-.}}